G.E. UPS Productline
description
Transcript of G.E. UPS Productline
G.E.UPS Productline
Uninterruptible Power Supplies | 1 PhaseDelivering reliable power in a compact footprint
LP11 / LP31T / LP31 Series
Application Medium data networks, telecom equipment, local site protection
Double conversion, high efficiency (up to 97%) and redundant parallel capable, with galvanic isolation and GE’s battery management for load security.
Line Interactive topology, automatic voltage regulation, step-wave output with internal hot swappable batteries.
IT & Match Series
Application Point-of-sale (POS), ISDN switches PCs, routers, & small IT servers
Application Healthcare & marine, wind turbine, controls, all IT & high speed processing
VH Series
GT SeriesDouble conversion, parallel-ready technology with modular battery and power components for easy expansion and retrofit.Application Telecom equipment, server racks, small to medium data networks
Double conversion technology, hardened design, peak load handling, and wide temperature operating range.
Rating Output Cert.600 VA – 2 kVA
120 Vac UL
500 VA – 3 kVA
230 Vac CE
Rating Output Cert.1 – 2kVA 120 Vac UL3kVA 120/208 Vac UL5 - 10kVA 120/208/240 Vac UL6 & 10kVA 220/230/240 Vac CE
Rating Output Cert.5-10 kVA 120/208/240 Vac UL &
CE3-10 kVA 220/230/240 Vac CE5-20 kVA 220/230/240 Vac CE
Rating Output Cert.2 kVA 208/220/230/240
VacUL
700 VA-3 kVA 208/220/230/240 Vac
CE
Uninterruptible Power Supplies | 3 PhaseClean, reliable and energy efficient power
The high efficiency SG series provides fast step/transient load response while eliminating single points of failure.
SG Series
ApplicationEnterprise class data networks,large data centers, healthcare equipment
The LP33 series is a transformer-less design reducing install footprint and installation time.
LP33 Series
Application Large data networks, telecom equipment
The SitePro model is a robust, double conversion UPS that provides true on-line operation and galvanic isolation.
SitePro
ApplicationManufacturing & process controlhealthcare equipment, data centers
Leading the industry through innovationRedundant Parallel Architecture (RPA)Increasing reliability by eliminating single points of failure. Paralleling multiple UPS’ for true redundancy without adding complexity.ECO ModePower supplied from mains via UPS bypass circuit. Immediate transfer to inverter power during disturbance. Energy efficiency of up to 98.5%.PurePulse ®Delivers pure clean waveform from the mains, reducing sizing of upfront equipment and eliminating additional input filters.
Rating Output Cert.
10 - 750 kVA
480 Vac UL
60 - 500 kVA
400 Vac CE
Rating Output Cert.
10 - 100 kVA
208 Vac UL
10 - 120 kVA
380/400/415 Vac
CE
Rating Output Cert.
10 - 40 kVA
380/400/415 Vac
CE
TLE Series Platform225 – 1500 kW
GECritical Power
Page 5 GE– Internal & Confidential
TLE Series 250-500 kVA/kW UL
TLE Series platform
Introducing TLE Series UPSWhat is it?TLE Series is a new high power transformer less 3 phase UPS platform with best in class multi-mode efficiency (eBoost and double conversion), and modular scalable from 200 kW up to 1500 kW for global UPS markets (CE and UL).
Why is it important?This TLE platform establishes GE technology leadership in mid/high power UPS applications with industry leading differentiation in efficiency, output power capacity and footprint.
Differentiated Value Proposition • Best in class multi-mode efficiency
• 96.5% Double Conversion mode (VFI)• 99.0% eBoost mode (VFD)
• Highest output power (up to 1.5 MW) • High reliability:
• Improved serviceability and lower MTTR• Standard building blocks 250 kw• Inherent redundancy inside UPS module
• High power density and small foot print• Excellent input , output performance
Page 6 GE– Internal & Confidential
TLE Series 250-500 kVA/kW UL
Ultra High Efficiency
Excellent Performance
Improved Diagnostic
High Reliability
High output power
Improved Serviceability
Creating Value – Low TCO
Page 7 GE– Internal & Confidential
TLE Series 250-500 kVA/kW UL
Creating Value – Low TCO
Ultra high Efficiency1
Page 8 GE– Internal & Confidential
TLE Series 250-500 kVA/kW UL
Double conversion Efficiency – 96.5%
High Efficiency at all loads Reduced customer operation costs and cost saving in air conditioning design
High efficiency performances High efficiency at full and partial
loads for real benefit in operating conditions
Energy cost savingReduced cost of customer equipment
operation at all loads
Air conditioning cost savingReducing size and cost of air
condition systemReducing consumption and related
operating cost
GE Sets the Bar for highest UPS Operating Efficiency
Page 9 GE– Internal & Confidential
TLE Series 250-500 kVA/kW UL
High Efficiency – eBoost mode
eBoosthigh efficiency (up to 99%)fast transfer to inverter
<2ms
"GE's eBoost feature expands a classic mode On-Line Double Conversion UPS System to a multi-mode UPS capable of maximizing operating efficiency commensurate with the stability of utility voltage and frequency
eBoost can be operated in RPA mode, up to 6 UPS modules in parallel, with all units operating and switching as one through redundant communication bus
Page 10 GE– Internal & Confidential
TLE Series 250-500 kVA/kW UL
High Efficiency – Low TCOHigh efficiency up to 96.5%Considerable life cycle cost savingsReduction in UPS operating costReduction in cooling cost
5 MW IT load - TLE series life cycle savings of $1.5 MM while operating in VFI mode
Assumptions: Power cost = $ 0.10 /kw-hr Operating hours/year = 8760Cooling factor = 0.35Configuration = S+S operating at
50% load
93%
96.5%
99%
Page 11 GE– Internal & Confidential
TLE Series 250-500 kVA/kW UL
High Efficiency – Low TCO
High efficiency up to 96.5%Considerable life cycle cost savingsReduction in UPS operating costReduction in cooling cost
Assumptions: Power cost = $ 0.10 /kw-hr Operating hours/year = 8760 Cooling factor = 0.35Configuration = 500 kW UPS @ 50%
load
TLE Series UPS annual savingsCompared to 92% efficiency UPS > $ 14,980 94% efficiency UPS > $ 8,140 95% efficiency UPS > $ 4,830
Page 12 GE– Internal & Confidential
TLE Series 250-500 kVA/kW UL
Creating Value – Low TCO
Excellent Performance2
Page 13 GE– Internal & Confidential
TLE Series 250-500 kVA/kW UL
UPS input performances Total Current Harmonic Distortion –
THDi <5% UPS input power factor: 0.99
Constant behavior at all loads Negligible harmonics contents at full
and partial loads
Programmable Soft Start Feature
Benefit on input mains Saving in the sizing of upfront
equipmente.g. GenSet, cablings, circuit breakers,
… No disturbances to nearby equipment Saving cost due to additional filters
Best in class input performance
Page 14 GE– Internal & Confidential
TLE Series 250-500 kVA/kW UL
High input performance means saving: GenSet size ( From 2 X Load kVA to 1.3 X Load kVA)
- Stable & longer life due to absence of harmonics
Circuit breaker size
Cabling section/size
Investment & space
Improved life for nearby equipments
No reactive power – saves on power compensation
Input performances benefit
Page 15 GE– Internal & Confidential
TLE Series 250-500 kVA/kW UL
Power capability – Unity power factor (kVA = kW)
Designed to supply real power for Unity power factor data centers load
Suitable for modern power supply application with unit or capacitive power factor (e.g. new servers generation), crest factor up to 3:1
UPS output power capability
11% more kW power compared to UPS with PF=0.9
No output voltage distortion with linear and non-linear loads
Voltage distortion- linear loads: THDv < 2-3%
- non-linear loads: THDv < 5%
Page 16 GE– Internal & Confidential
TLE Series 250-500 kVA/kW UL
UPS Input-Output PerformanceModule size optimization/ Electrical infrastructure utilization
4000 A Input Bus
6 x TLE 500 kW4 x TLE 750 kW
3 x TLE 1000 kW
2 x 1500 KW
3 MW Power
3000 A Input Bus
4 x TLE 500 kW3 x TLE 750 kW
2 X 1000 kW
2.25 / 2 MW Power
2000 A Input Bus
3 x TLE 500 kW2 x TLE 750 kW
1 x 1500 kW
1.5MW Power
11% more kW power compared to UPS with PF=0.9
Competitors units with 0.9 power factor provides less output power from same input bus size
Page 17 GE– Internal & Confidential
TLE Series 250-500 kVA/kW UL
Creating Value – Low TCO
Improved Diagnostic High Reliability3
Page 18 GE– Internal & Confidential
TLE Series 250-500 kVA/kW UL
New FLEX DSP board: the black-box• Waveform capture, diagnostic and trend analysis• Simultaneous acquisition of 32 channels• Sampling frequency up to 10kHz• Smart trigger capability with up to 16 indipendent trigger
sources to record only specific events with pre/post trigger data acquisition
• Buffer depth of 1000 samples per channel: each event is recorded for 100ms @ s.f. 10kHz
• 8 buffers to record up to 8 events without losing older events – can be extended with external USB mass storage devices
WAVEFORMS• Inverter voltages • Bypass voltages • Input mains voltages • Output voltages: • Output current Phases:• Input capacitors “Cin” voltages:• Inverter primary current: • Input current: • IDC current: • Battery current: • Bypass current:• UDC• Communication status RPA• Auxiliary status• SSM status• Fuses status• Phase error slave master.
Page 19 GE– Internal & Confidential
TLE Series 250-500 kVA/kW UL
Creating Value – Low TCO
Ease of InstallationImproved Serviceability4
Page 20 GE– Internal & Confidential
TLE Series 250-500 kVA/kW UL
Reduced footprint Compact design saving space in
installation- 225-250 kW: (w x d x h)
44.4 x 33.9 x 75.1 inch-400-500 kW:
66.9 x 33.9 x 75.1 inch
Standard Top-bottom cable entry Easier to handle High power density Savings in installation space
Compact design
1907 / 75.1”
1100 / 43.3”
TLE Series 250 kW
Page 21 GE– Internal & Confidential
TLE Series 250-500 kVA/kW UL
Improved serviceability
Improving Mean Time to Repair & Installation
Front access construction/design Draw out construction for fans & power
modules Common 250 kW power block & common
components Faster power block MTTR Easy access to customer connections Easy access to connectivity
Improved diagnostic capability
iUPS Guard – Remote monitoring
Standard back feed protectionInternal Option - Q2 (TLE 250-500) External Option – Q2 (TLE 750 -1500)
Page 22 GE– Internal & Confidential
TLE Series 160-400 kVA/kW CE
Installation flexibility – RPA Cable Saver
1A2A3A
1B
2B
3B
Bypass input to UPS
Output from UPS
Competitors – 1A=2A=3A and 1B=2B=3B or max 10% difference
TLE Series with inductor = allows variation up to 20-25% (depends on UPS rating & cable section
Page 23 GE– Internal & Confidential
TLE Series 250-500 kVA/kW UL
Menu driven touch screen 7” display Critical measurement of input, output and battery included with mimic
diagram Quick operational status Different access level for user and service Different mimic diagram based on configuration Multilanguage communication interface
Advanced User Interface
Metering
Alarm
Set up
Command
RPA System
Page 24 GE– Internal & Confidential
TLE Series 250-500 kVA/kW UL
Advanced User Interface
Menu driven touch screen display
Page 25 GE– Internal & Confidential
TLE Series 250-500 kVA/kW UL
Advanced User Interface
Menu driven touch screen display Separate screen for RPA system with status and measurements Metering screen by tabs Home button inside each screen Improved alarm and events screen Easy to use set up screen
Page 26 GE– Internal & Confidential
TLE Series 250-500 kVA/kW UL
Creating Value – Low TCO
Summary5
Page 27 GE– Internal & Confidential
TLE Series 250-500 kVA/kW UL
Differentiated TLE Series UPS
Efficiency
Black BoxLimited life component monitoring
High Reliability
Small foot printProduct options
Font accessNew control
panelDraw out
construction
96.5%THDi 3-5%, Input pf 0.99Output pf -1
Page 28 GE– Internal & Confidential
TLE Series 250-500 kVA/kW UL
TLE Series UPS
Differentiating:• Best in class double conversion efficiency - up to 96.5%• Ultra high efficiency in eBoost mode of operation - up to
99%• Static bypass inductor • Compact foot print provides very high power density• Excellent input, output performance• Improved diagnostic capability with black box• Ease of installation and Improved serviceability
Page 29 GE– Internal & Confidential
TLE Series 250-500 kVA/kW UL
3-Level topology
High Efficiency at all loads Reduced customer operation costs and cost saving in air conditioning design
High efficiency performances The TLE Series UPS uses a three level technology with an Advanced Neutral Point Clamped topology implemented with true Reverse Blocking IGBT. These result in reduced switching and filter losses with respect to a standard two level technology
Page 30 GE– Internal & Confidential
TLE Series 250-500 kVA/kW UL
Improved diagnostic, High Reliability
Improving Mean Time to Repair Wave form capture capability Fan failure detection
Improving Reliability & Diagnostic AC Capacitor health monitoring Component life time counters Dedicated supply path for bypass logic Redundant Isolated power supply Robust RPA communication No total OFF button to avoid human error Heat sink & input, output filter coils temperature
monitoring
Page 31 GE– Internal & Confidential
TLE Series 250-500 kVA/kW UL
• Double conversion (VFI) technology• Automatic bypass for overloads, short circuit and UPS disturbances
conditions • Manual bypass Q2 (optional) for UPS maintenance operations without
load interruption (225-500 kW internal option) • Standard common mains• Number of battery blocks – 40-42
- back feed protection K6 standard
UPS configurationOptional – TLE Series 225-500 kW
TLE Series 225-500 kW
Page 32 GE– Internal & Confidential
TLE Series 250-500 kVA/kW UL
Supplemental Cabinetry• VRLA Battery Cabinet Systems• Flywheel DC Energy Storage• 480/480V External Maintenance Bypass• 480/208V External Maintenance Bypass (250kw max)
Optional Equipment• 480/415VAC Input Isolation Xfmr• 600VAC Input Isolation Xfmr• Remote Alarm Status Panel• Dual Input• RPA Card for parallel operation• eBoost Software for multi-mode operation
Installation flexibility - Product options
ISM (intelligent Synchronization module) – not supported
Page 33 GE– Internal & Confidential
TLE Series 250-500 kVA/kW UL
Remote monitoring – TLE Series
iUPSGuard – Remote monitoring
Improved response time 24 x7 monitoring & alarm
notification of UPS Improved pre dispatch diagnostic
& first time fix Regular status reports Highly secure communication
Page 34 GE– Internal & Confidential
TLE Series 250-500 kVA/kW UL
Customer ConnectivityEasy integration with Building Management System (BMS)
Customer interfaceUPS supervision capability1x RS232 Serial Communication Port6 programmable potential free alarm
contacts: - D plug - Terminals blocks
1x Emergency Power OFF contact1x Gen-ON Input contact1x Control Input contact
Additional interface:SNMP Interface Card
(10/100Mbps auto-select)MODBUS Interface (RS232 or RS485)iUPSGuard (free license during
warranty)- SNMP card required for iUPSGuard
Page 35 GE– Internal & Confidential
TLE Series 250-500 kVA/kW UL
Configurable up to 6 units in parallel
Future expansion Safe and reliable power supplyRedundant Communication Bus
Redundant Parallel Architecture
Easy to install and maintainEasy system upgrade/downgradeMaintenance operation without
load interruptionRPA cable saver allows
installation flexibility
System reliability improved by RPA
Page 36 GE– Internal & Confidential
TLE Series 250-500 kVA/kW UL