Fire Panels
The NKB600 Series microprocessor controlled, conventional fire panelsincorporate state of the art technology, reliability, ease of installation andmaintenance in a basic package. They are compatible with conventionaldetectors such as the Kilsen 200, 300, 500 and 700 series devices. TheNKB602 has 2 conventional zones.
Technical Data
Supply Voltage 125/230 VAC @ 50/60 HzMains fuse (Type 5x20 mm) 0.5/0.25 ATotal consumption < 20 WNominal Output Voltage 24 VDC
BatteriesRecommended batteries 2 off 1.9 Ah, 12 VFuse Rating 1 AMaximum load current < 100 mA
ZoneMaximum Load 72 mAMaximum number of detectors 20Ouput voltage 22 to 28 VDCEnd-of-line resitance 4k7 OhmManual call point resistance 100 Ohm, 2 W
OutputsFire alarm 24 VDC ± 15%, 300 mAFault alarm (Fail-to-safe) 24 VDC ± 15%, 100 mA
EnvironmentalWorking temperature +5 to +40°CStorage temperature -10 to +70°CRelative humidity 95 % (non-condencing)
Physical CharacteristicsSize (w x h x d) 305 x 295 x 100 mmWeight without batteries 3 kg
Ordering Information
NKB602 Conventional fire alarm panel with 2 zones
Modern, elegant design
Compact models for 2, 4 and 6 zones
Microprocessor controlled
Multilingual keyboard
2 Access levels
Differentiation between alarms from manual call points andautomatic detectors in the same zone
Acoustic indications for fire and fault
Optical indications for fire and fault by zone
Low maintenance
Compatible with all ranges of KILSEN conventional detectors
Conventional fire alarm panel with 2 zones NKB602
Page 2
Fire Panels
The NKB600 Series microprocessor controlled, conventional fire panelsincorporate state of the art technology, reliability, ease of installation andmaintenance in a basic package. They are compatible with conventionaldetectors such as the Kilsen 200, 300, 500 and 700 series devices. TheNKB604 has 4 conventional zones.
Technical Data
Supply Voltage 125/230 VAC @ 50/60 HzMains fuse (Type 5x20 mm) 0.5/0.25 ATotal consumption < 20 WNominal Output Voltage 24 VDC
BatteriesRecommended batteries 2 off 1.9 Ah, 12 VFuse Rating 1 AMaximum load current < 100 mA
ZoneMaximum Load 72 mAMaximum number of detectors 20Ouput voltage 22 to 28 VDCEnd-of-line resitance 4k7 OhmManual call point resistance 100 Ohm, 2 W
OutputsFire alarm 24 VDC ± 15%, 300 mAFault alarm (Fail-to-safe) 24 VDC ± 15%, 100 mA
EnvironmentalWorking temperature +5 to +40°CStorage temperature -10 to +70°CRelative humidity 95 % (non-condencing)
Physical CharacteristicsSize (w x h x d) 305 x 295 x 100 mmWeight without batteries 3 kg
Ordering Information
NKB604 Conventional fire alarm panel with 4 zones
Modern, elegant design
Compact models for 2, 4 and 6 zones
Microprocessor controlled
Multilingual keyboard
2 Access levels
Differentiation between alarms from manual call points andautomatic detectors in the same zone
Acoustic indications for fire and fault
Optical indications for fire and fault by zone
Low maintenance
Compatible with all ranges of KILSEN conventional detectors
Conventional fire alarm panel with 4 zones NKB604
Page 3
Fire Panels
The NKB600 Series microprocessor controlled, conventional fire panelsincorporate state of the art technology, reliability, ease of installation andmaintenance in a basic package. They are compatible with conventionaldetectors such as the Kilsen 200, 300, 500 and 700 series devices. TheNKB606 has 6 conventional zones.
Technical Data
Supply Voltage 125/230 VAC @ 50/60 HzMains fuse (Type 5x20 mm) 0.5/0.25 ATotal consumption < 20 WNominal Output Voltage 24 VDC
BatteriesRecommended batteries 2 off 1.9 Ah, 12 VFuse Rating 1 AMaximum load current < 100 mA
ZoneMaximum Load 72 mAMaximum number of detectors 20Ouput voltage 22 to 28 VDCEnd-of-line resitance 4k7 OhmManual call point resistance 100 Ohm, 2 W
OutputsFire alarm 24 VDC ± 15%, 300 mAFault alarm (Fail-to-safe) 24 VDC ± 15%, 100 mA
EnvironmentalWorking temperature +5 to +40°CStorage temperature -10 to +70°CRelative humidity 95 % (non-condencing)
Physical CharacteristicsSize (w x h x d) 305 x 295 x 100 mmWeight without batteries 3 kg
Ordering Information
NKB606 Conventional fire alarm panel with 6 zones
Modern, elegant design
Compact models for 2, 4 and 6 zones
Microprocessor controlled
Multilingual keyboard
2 Access levels
Differentiation between alarms from manual call points andautomatic detectors in the same zone
Acoustic indications for fire and fault
Optical indications for fire and fault by zone
Low maintenance
Compatible with all ranges of KILSEN conventional detectors
Conventional fire alarm panel with 6 zones NKB606
Page 4
Fire Panels
The NK700 series of conventional fire alarm and extinguishing control panelsis the ideal solution for small to medium-sized installations. Very powerfuland cost-effective, they are extremely simple to install and use due to theirergonomic, advanced design. The NK704 has 4 conventional zones.
Technical Data
Supply Voltage (+10% - 15%) 230 VAC @ 50 Hz / 110 VAC @ 60 HzBatteries
Capacity 2 x 2.3 AhFuse rating 2 A
ZoneMaximum load 94 mAMax. number of detectors per zone 20Maximum zone resistance 44 ohm
SoundersMaximum load 250 mADelay Selectable 0 - 9 min
Relay Outputs (excluding sounders) 1 A @ 30 VDCExtinguishing Relay Outputs
Maximum load NAFuse rating NA
Auxilliary Output 250 mA24 VDC Resetable Output
Maximum Load 100 mAReset time 3 s
EnvironmentWorking temperature -5°C to +40°CRelative humidity (non condencing) 95 %IP rating IP30
Physical CharacteristicsSize (mm) 297 (w) x 307 (h) x 105 (d)Weight (without batteries) 3.6 kg
Ordering Information
NK702 Conventional fire panel with 2 fire alarm zones
Modern, attractive design
Microprocessor-controlled
From 2 up to 16-zones
EN54 compliant with approvals pending
2 User access levels
2 Monitored sounder outputs
One-man test capability
Open-collector output for every zone
24 Volt resetable output
External ‘Class Change’ facility
Alarm output with potential free relay
Common fault output with potential free relay
External watchdog
Active end-of-line support
Conventional fire panel with 2 fire alarm zones NK702
Page 5
Fire Panels
The NK700 series of conventional fire alarm and extinguishing control panelsis the ideal solution for small to medium-sized installations. Very powerfuland cost-effective, they are extremely simple to install and use due to theirergonomic, advanced design. The NK704 has 4 conventional zones.
Technical Data
Supply Voltage 230 VAC @ 50 Hz (±10%)Batteries
Capacity 2 x 7.5 AhFuse Rating 1 A
ZoneMaximum Load 72 mAMax number of detectors 20
SoundersMaximum Load 300 mA
Relay Outputs (excluding Sounders) 2 A @ 250 VExtinguishing relay outputs
Maximum Load NAFuse Rating NA
Open Collector outputs 15 mAAuxilliary Output
Maximum Load 300 mA24 V resetable output
Maximum Load 150 mAReset time 4 seconds
DelaysSounder Selectable 0.15 & 60 sRelay module 3 to 180 s
EnviromentWorking Temperature +5°C to +40 °CRelative humidity 95 % (non-condensing)
Ordering Information
NK704 Conventional fire panel with 4 fire alarm zones
Modern, attractive design
Microprocessor-controlled
From 2 up to 16-zones
EN54 compliant with approvals pending
2 User access levels
2 Monitored sounder outputs
One-man test capability
Open-collector output for every zone
24 Volt resetable output
External ‘Class Change’ facility
Alarm output with potential free relay
Common fault output with potential free relay
External watchdog
Active end-of-line support
Conventional fire panel with 4 fire alarm zones NK704
Page 6
Fire Panels
The NK700 series of conventional fire alarm and extinguishing control panelsis the ideal solution for small to medium-sized installations. Very powerfuland cost-effective, they are extremely simple to install and use due to theirergonomic, advanced design. The NK708 has 8 conventional zones.
Technical Data
Supply Voltage (+10% - 15%) 230 / 110 VAC @ 50 / 60 HzBatteries
Capacity 2 x 7.5 AhFuse rating 5 A
ZoneMaximum load 94 mAMax. number of detectors per zone 20Maximum zone resistance 44 ohm
SoundersMaximum load 250 mADelay Selectable 0 - 9 min
Relay Outputs (excluding sounders) 1 A @ 30 VDCExtinguishing Relay Outputs
Maximum load NAFuse rating NA
Auxilliary Output 250 mA24 VDC Resetable Output
Maximum load 100 mAReset time 3 s
EnvironmentWorking temperature -5°C to +40°CRelative humidity (non condencing) 95 %IP rating IP30
Physical CharacteristicsSize (mm) 420 (w) x 335 (h) x 110 (d)Weight (without batteries) 6.2 kg
Ordering Information
NK708 Conventional fire panel with 8 fire alarm zones
Modern, attractive design
Microprocessor-controlled
From 2 up to 16-zones
EN54 compliant with approvals pending
2 User access levels
2 Monitored sounder outputs
One-man test capability
Open-collector output for every zone
24 Volt resetable output
External ‘Class Change’ facility
Alarm output with potential free relay
Common fault output with potential free relay
External watchdog
Active end-of-line support
Conventional fire panel with 8 fire alarm zones NK708
Page 7
Fire Panels
The NK700 series of conventional fire alarm and extinguishing control panelsis the ideal solution for small to medium-sized installations. Very powerfuland cost-effective, they are extremely simple to install and use due to theirergonomic, advanced design. The NK712 has 12 conventional zones.
Technical Data
Supply Voltage (+10% - 15%) 230 VAC @ 50 Hz / 110 VAC @ 60 HzBatteries
Capacity 2 x 7.5 AhFuse rating 5 A
ZoneMaximum load 94 mAMax. number of detectors per zone 20Maximum zone resistance 44 ohm
SoundersMaximum load 250 mADelay Selectable 0 - 9 min
Relay Outputs (excluding sounders) 1 A @ 30 VDCExtinguishing Relay Outputs
Maximum load NAFuse rating NA
Auxilliary Output 250 mA24 VDC Resetable Output
Maximum Load 100 mAReset time 3 s
EnvironmentWorking temperature -5°C to +40°CRelative humidity (non condencing) 95 %IP rating IP30
Physical CharacteristicsSize (mm) 420 (w) x 335 (h) x 110 (d)Weight (without batteries) 6.2 kg
Ordering Information
NK712 Conventional fire panel with 12 fire alarm zones
Modern, attractive design
Microprocessor-controlled
From 2 up to 16-zones
EN54 compliant with approvals pending
2 User access levels
2 Monitored sounder outputs
One-man test capability
Open-collector output for every zone
24 Volt resetable output
External ‘Class Change’ facility
Alarm output with potential free relay
Common fault output with potential free relay
External watchdog
Active end-of-line support
Conventional fire panel with 12 fire alarm zones NK712
Page 8
Fire Panels
The NK700 series of conventional fire alarm and extinguishing control panelsis the ideal solution for small to medium-sized installations. Very powerfuland cost-effective, they are extremely simple to install and use due to theirergonomic, advanced design. The NK716 has 16 conventional zones.
Technical Data
Supply Voltage (+10% - 15%) 230 VAC @ 50 Hz / 110 VAC @ 60 HzBatteries
Capacity 2 x 7.5 AhFuse rating 5 A
ZoneMaximum load 94 mAMax. number of detectors per zone 20Maximum zone resistance 44 ohm
SoundersMaximum load 250 mADelay Selectable 0 - 9 min
Relay Outputs (excluding sounders) 1 A @ 30 VDCExtinguishing Relay Outputs
Maximum load NAFuse rating NA
Auxilliary Output 250 mA24 VDC Resetable Output
Maximum Load 100 mAReset time 3 s
EnvironmentWorking temperature -5°C to +40°CRelative humidity (non condencing) 95 %IP rating IP30
Physical CharacteristicsSize (mm) 420 (w) x 335 (h) x 110 (d)Weight (without batteries) 6.2 kg
Ordering Information
NK716 Conventional fire panel with 16 fire alarm zones
Modern, attractive design
Microprocessor-controlled
From 2 up to 16-zones
EN54 compliant with approvals pending
2 User access levels
2 Monitored sounder outputs
One-man test capability
Open-collector output for every zone
24 Volt resetable output
External ‘Class Change’ facility
Alarm output with potential free relay
Common fault output with potential free relay
External watchdog
Active end-of-line support
Conventional fire panel with 16 fire alarm zones NK716
Page 9
Extinguishing Panels
The NK703 conventional fire alarm and extinguishing control panels is theideal solution for small to medium-sized installations. Very powerful and cost-effective, they are extremely simple to install and use due to their ergonomic,advanced design. It has 1 double-knock extinguising area consisting of twofire zones, and 1 free fire detection zone.
Technical Data
Supply Voltage (+10% - 15%) 230 VAC @ 50 Hz / 110 VAC @ 60 HzBatteries
Capacity 2 x 7 AhFuse rating 2 A
ZoneMaximum load 94 mAMax. number of detectors per zone 20Maximum zone resistance 44 ohm
SoundersMaximum load 250 mADelay Selectable 0 - 9 min
Relay Outputs (excluding sounders) 1 A @ 30 VDCExtinguishing Relay Outputs
Maximum load 250 mAFuse rating 0.3 A
Auxilliary Output 250 mA24 VDC Resetable Output
Maximum Load 100 mAReset time 3 s
EnvironmentWorking temperature -5°C to +40°CRelative humidity (non condencing) 95 %IP rating IP30
Physical CharacteristicsSize (mm) 420 (w) x 335 (h) x 110 (d)Weight (without batteries) 6.2 kg
Ordering Information
NK703 Conventional extinguishing control panel with 3 zones
Modern, attractive design
Microprocessor controlled
3 zone (1 ext. area) and 6 zone (2 ext. areas) available
Automatic extinguishing agent release control
EN54 compliant
2 Access levels
Supervised general sounder output
Supervised extinguishing inputs and outputs
One-man test capability
24 Volt resetable output
External ‘class change’ facility
Alarm output with potential free relay
General fault output with potential free relay
External watchdog
Conventional extinguishing control panel with 3 zones NK703
Page 10
Extinguishing Panels
The NK706 conventional fire alarm and extinguishing control panels is theideal solution for small to medium-sized installations. Very powerful and cost-effective, they are extremely simple to install and use due to their ergonomic,advanced design. It has 2 double-knock extinguising areas consisting of twofire zones each, and 2 free fire detection zones.
Technical Data
Supply Voltage (+10% - 15%) 230 VAC @ 50 Hz / 110 VAC @ 60 HzBatteries
Capacity 2 x 7 AhFuse rating 2 A
ZoneMaximum load 94 mAMax. number of detectors per zone 20Maximum zone resistance 44 ohm
SoundersMaximum load 250 mADelay Selectable 0 - 9 min
Relay Outputs (excluding sounders) 1 A @ 30 VDCExtinguishing Relay Outputs
Maximum load 250 mAFuse rating 0.3 A
Auxilliary Output 250 mA24 VDC Resetable Output
Maximum Load 100 mAReset time 3 s
EnvironmentWorking temperature -5°C to +40°CRelative humidity (non condencing) 95 %IP rating IP30
Physical CharacteristicsSize (mm) 420 (w) x 335 (h) x 110 (d)Weight (without batteries) 6.2 kg
Ordering Information
NK706 Conventional extinguishing control panel with 5 zones
Modern, attractive design
Microprocessor controlled
3 zone (1 ext. area) and 6 zone (2 ext. areas) available
Automatic extinguishing agent release control
EN54 compliant
2 Access levels
Supervised general sounder output
Supervised extinguishing inputs and outputs
One-man test capability
24 Volt resetable output
External ‘class change’ facility
Alarm output with potential free relay
General fault output with potential free relay
External watchdog
Conventional extinguishing control panel with 5 zones NK706
Page 11
Expansion Modules
The RB404 relay expander module has voltage-free 4 relays. The unit allowsfor a relay for each detection zone or for programming the activation ofdifferent relays depending on the status of one or more zones. It is used on theGE-Interlogix NK700/FP400 conventional fire panel range.
Technical Data
Relay RatingVoltage 230 VDCCurrent 2 A
Delay setting 0 to 9 minutes
Ordering Information
RB404 Relay module, 4 potential free relays for NK700/Fx400 fire panels
4 Potential free relays
Up to 4 modules may be housed inside the fire panel cabinet
Programable with basic boolen functions
Power supplied from fire panel bus
Output delay setting per relay
Relay module, 4 potential free relays for NK700/Fx400 fire panels RB404
The SB404 module has 4 relays that provide 4 of 24 VDC supervised outputs.These may be configured to power sounders or as standard 24 VDC supervisedoutputs for other devices.
Technical Data
Aux. Supply 24 VDCDelay Setting 0 to 9 minutes
Ordering Information
SB404 Relay module, 4 supervised relays for NK700/Fx400 fire panels
4 Supervised relays
Up to 4 modules may be housed inside the fire panel cabinet
Programable with basic boolen functions
Output delay setting per relay
Configurable for sounder control or as supervised outputs
Relay module, 4 supervised relays for NK700/Fx400 fire panels SB404
Page 12
Fire Panels
The KSA701 analogue addressable fire alarm control panel is the idealsolution for small to medium-sized installations. Very powerful and cost-effective, it is extremely simple to install and use due to its ergonomic,advanced design. The panel is supplied in an elegant, high-quality,conveniently sized, heavy-duty enclosure. The cabinet allows for enough spacefor the batteries for the system to be housed inside the cabinet. The KSA701 isfully compatible with the Kilsen 700A series detectors and KAL400 seriesaccessories.
Technical Data
Supply Voltage 110 VAC @ 50 Hz or 230 VAC @ 50 Hz (+10% -15%)
Current Consumption 175 mA Quiescent / 241 mA in alarm with nodevices connected
BatteriesCapacity 2 x 12 V - 7 AH (SLA type)Fuse Rating 3 ACharger Rating 350 mA @ 27.6 VDC @ 20 °C (Temperature
compensated -3 V / °C)Loop characteristics per loop
Capacity 125 addresses per loopMaximum Load 400 mA / 26 VDC to 32 VDCMaximum Electrical Characteristics 44 Ohm / 500 nF approximately 2 km of
1.5 mm2 diameter cableSounders (reverse polarity supervision)
Maximum Load 250 mA each (2 Sounder outputs available) / 18VDC to 24 VDC
Delays 10 seconds to 600 seconds, software adjustable in10 second intervals
Relay Outputs (potential free) 1 A @ 30 VDC24 V Auxiliary Output
Maximum Load 250 mA @ 18 VDC to 28 VDCEnvironment
Working Temperature -5°C to +40 °CRelative Humidity 0-95% non-condensingIP Rating IP30
Physical CharacteristicsSize 420 mm (w) x 335 (h) x 110 (d)Weight 6.2 kg without batteries / 10.7 kg with 2 x 7 Ah
batteries
Ordering Information
KSA701
4 x 40 characters LCD display
20 Display zones
EN54 compliant with approvals pending
4 User access levels
2 Monitored sounder outputs
2 Programmable voltage free relays
24 Volt auxiliary output
I/O programming capabilities with Boolean functions
Day/night sensitivity settings
Coincidence within zones
Upload/download and graphic PC software
Panel networking
Installation test capability
Analogue addressable fire detection panel - 1 loop KSA701/1
Page 13
Fire Panels
The KSA701 analogue addressable fire alarm control panel is the idealsolution for small to medium-sized installations. Very powerful and cost-effective, it is extremely simple to install and use due to its ergonomic,advanced design. The panel is supplied in an elegant, high-quality,conveniently sized, heavy-duty enclosure. The cabinet allows for enough spacefor the batteries for the system to be housed inside the cabinet. The KSA701 isfully compatible with the Kilsen 700A series detectors and KAL400 seriesaccessories.
Technical Data
Supply Voltage 110 VAC @ 50 Hz or 230 VAC @ 50 Hz (+10% -15%)
Current Consumption 175 mA Quiescent / 241 mA in alarm with nodevices connected
BatteriesCapacity 2 x 12 V - 7 AH (SLA type)Fuse Rating 3 ACharger Rating 350 mA @ 27.6 VDC @ 20 °C (Temperature
compensated -3 V / °C)Loop characteristics per loop
Capacity 125 addresses per loopMaximum Load 400 mA / 26 VDC to 32 VDCMaximum Electrical Characteristics 44 Ohm / 500 nF approximately 2 km of
1.5 mm2 diameter cableSounders (reverse polarity supervision)
Maximum Load 250 mA each (2 Sounder outputs available) / 18VDC to 24 VDC
Delays 10 seconds to 600 seconds, software adjustable in10 second intervals
Relay Outputs (potential free) 1 A @ 30 VDC24 V Auxiliary Output
Maximum Load 250 mA @ 18 VDC to 28 VDCEnvironment
Working Temperature -5°C to +40 °CRelative Humidity 0-95% non-condensingIP Rating IP30
Physical CharacteristicsSize 420 mm (w) x 335 (h) x 110 (d)Weight 6.2 kg without batteries / 10.7 kg with 2 x 7 Ah
batteries
Ordering Information
KSA702 Analogue addressable fire panel (expandable to 2 loops)
4 x 40 characters LCD display
20 Display zones
EN54 compliant with approvals pending
4 User access levels
2 Monitored sounder outputs
2 Programmable voltage free relays
24 Volt auxiliary output
I/O programming capabilities with Boolean functions
Day/night sensitivity settings
Coincidence within zones
Upload/download and graphic PC software
Panel networking
Installation test capability
Analogue addressable fire detection panel - 2 loops KSA701/2
Page 14
Fire Panels
The KSA700 Series analogue addressable fire panels offer leading-edgetechnology for the control of analogue addressable fire detection devices.Their unique user-friendly programming facilitate the ideal controlenvironment for either simple or complex fire systems.
Technical Data
Supply Voltage 230 VAC @ 50 Hz (+10% -15%)Current Consumption
(no devices connected) 175 mA Quiest. / 241 mA AlarmBatteries
Capacity 2 x 12 V - 6 AH (SLA type)Fuse Rating 4 ACharger (Temp. comp. -3 V / °C) 350 mA @ 27.6 VDC @ 20 °C
Loop characteristics per loopCapacity 250 addressesMaximum Load 400 mA / 26 VDC to 32 VDCMaximum Electrical Characteristics 44 Ohm / 500 nF
Sounders (reverse polarity supervision)Maximum Load (2 Outputs) 250 mA each / 18 to 24 VDCDelays (adjustable in 10 s intervals) 10 to 600 seconds
Relay Outputs (potential free) 1 A @ 30 VDC24 V Auxiliary Output
Maximum Load 800 mA @ 18 to 28 VDCEnvironment
Working Temperature -5°C to +40 °CRelative Humidity (non-condensing) 0-95%IP Rating IP41
Physical CharacteristicsSize 480 mm (w) x 455 (h) x 140 (d)Weight (without batteries) 13.6 kg
Ordering Information
KSA705 Analogue addressable fire panel (expandable to 5 loops)
4-line, 40-character LCD display
Panel networking capability
Graphic monitoring software
Windows based up/download programming software
Remote programming and maintenance via modem and TCP/IP
Repeater facilities
Powerful auto-configuration functions
Simple program options with on-screen menu selection
EN54 approvals pending
Analogue addressable fire panel (expandable to 5 loops) KSA705
Page 15
Fire Panels
The KSA700 Series analogue addressable fire panels offer leading-edgetechnology for the control of analogue addressable fire detection devices.Their unique user-friendly programming facilitate the ideal controlenvironment for either simple or complex fire systems. The KSA705P offers anadditional internal printer facility.
Technical Data
Supply Voltage 230 VAC @ 50 Hz (+10% -15%)Current Consumption (with no devices connected) 175 mA Quiescent / 241 mA in alarmBatteries
Capacity 2 x 12 V - 6 AH (SLA type)Fuse Rating 4 ACharger Rating (Temperature compensated -3 V / °C) 350 mA @ 27.6 VDC @ 20
°CLoop characteristics per loop
Capacity 250 addressesMaximum Load 400 mA / 26 VDC to 32 VDCMaximum Electrical Characteristics 44 Ohm / 500 nF approximately 2 km of
1.5 mm2 diameter cableSounders (reverse polarity supervision)
Maximum Load 250 mA each (2 Sounder outputs available) / 18VDC to 24 VDC
Delays (software adjustable in 10 second intervals) 10 to 600 secondsRelay Outputs (potential free) 1 A @ 30 VDC24 V Auxiliary Output
Maximum Load 800 mA @ 18 VDC to 28 VDCEnvironment
Working Temperature -5°C to +40 °CRelative Humidity (non-condensing) 0-95%IP Rating IP41
Physical CharacteristicsSize 480 mm (w) x 455 (h) x 140 (d)Weight 13.6 kg without batteries / 21.6 kg with 2 x 7 Ah
batteries
Ordering Information
KSA705P Analogue addressable fire panel with printer (expandable to 5 loops)
4-line, 40-character LCD display
Panel networking capability
Graphic monitoring software
Windows based up/download programming software
Remote programming and maintenance via modem and TCP/IP
Repeater facilities
Powerful auto-configuration functions
Simple program options with on-screen menu selection
EN54 approvals pending
Analogue addressable fire panel with printer (expandable to 5 loops) KSA705P
Page 16
Repeater Panels
The KSA701R repeater allows the user to monitor and control panelsconnected to the KSA700 fire panel network via and RS485 link. It displays 20zones in alarm and fault on the face of the panel, whilst all systemnmessages are displayed on the easy to read, LCD display.
Technical Data
Supply VoltageAC Version 110 VAC @ 50 Hz or 230 VAC @ 50 Hz (+10% -
15%)DC Version 24 VDC
Current Consumption 175 mA Quiescent / 200 mA in alarmBattery Charger (AC Version only)
Capacity 2 x 12 V - 7 AH (SLA type)Fuse Rating 3 ACharger Rating 350 mA @ 27.6 VDC @ 20 °C (Temperature
compensated -3 V / °C)Environment
Working Temperature -5°C to +40 °CRelative Humidity 0-95% non-condensingIP Rating IP30
Physical CharacteristicsSize 420 mm (w) x 335 (h) x 110 (d)Weight 6.2 kg without batteries / 10.7 kg with 2 x 7 Ah
batteriesCommunication Ports RS232 and RS485 standard
Ordering Information
KSA701R KSA700 Series LCD Repeater
Modern, attractive design
4 x 40 characters LCD display
20 Display zones
3 User access levels
24 VDC or 230 VAC models available
Panel networking
Full system control
EN54 compliant with approvals pending
KSA700 Series LCD Repeater KSA701R
Page 17
Expansion Modules
The MODGSM modem may be used in KSA701/FP1500, KSA702 and KSA705fire panel from GE-Interlogix. It is ideal for use as a standard modem formaking and receiving calls from and to the fire panel, but may also be usedfor GSM messaging.
Technical Data
GSM Band 900/1800 MHzServices Data, SMS, Voice and FaxAT Commands GSM 07.07 and 07.05Output Power (max)
GSM900 2 WGSM1800 1 W
Input Voltage 5 to 32 VCurrent @ 5V
Avarage 330 mAPeak 1.8 A
SIM Interface 3V / 5VDimensions (h x w x d) 98 x 54 x 25 mmWeight 130 gEnvironmental Temperature
Storage - 25 °C to + 70 °COperating - 20 °C to + 55 °C
Ordering Information
MODGSM GSM Modem for Kilsen Fire Panels
Dual-Band 90/1800 MHz
Data and SMS services
Remote control by AT commands
Wide input voltage range
GSM Modem for Kilsen Fire Panels MODGSM
Page 18
Expansion Modules
The KAL701 1 loop expander allows for an easy upgrade to the KSA702 andKSA705 analalogue addressable fire panels. Each module consist of a simpleplug in card and requires no additional settings or connections for fullfunctionality. The KAL701 has loop isolators supplied on both drivers andalows full class-A loop functionality with up to 250 device addresses.
Technical Data
Number of loops 1Loop characteristics
Capacity 250 addressesMaximum Load 400 mA / 26 VDC to 32 VDCMaximum Electrical Characteristics 44 Ohm / 500 nFMaximum Loop Length 2 km
Ordering Information
KAL701 Loop driver module for KSA702/705 control panels
Expands the loop capabailities of the KSA702 and KSA705
Allows for the connection of an additional 250 devices per unit
Two isolated drivers support full class-A operation
No hardware configuration required
Loop driver module for KSA702/705 control panels KAL701
The KAL732 RS232 expander allows for an easy upgrade to the KSA702 andKSA705 analalogue addressable fire panels. Each module adds an additionalindustry standard RS232 communication port to the panel. This port could beused for communications with a PC or for connections to a printer or modem.
Technical Data
Number of ports 1Communications medium RS232Technical specifications
Maximum cable length 15 mCommunication speed 9600 baudCable 3 core with screen
Ordering Information
KAL732 RS232 communications module for KSA702/5 control panels
Industry standard RS232 communications
No hardware configuration required
RS232 communications module for KSA702/5 control panels KAL732
Page 19
Expansion Modules
The KAL785 RS485 expander allows for an easy upgrade to the KSA702 andKSA705 analalogue addressable fire panels. Each module adds an additionalindustry standard RS485 communication port to the panel. This port could beused for communications with other network nodes in the fire panel network.
Technical Data
Number of ports 1Communications medium RS485Technical specifications
Maximum cable length 1200 mCommunication speed 9600 baudCable CAT5 - twisted with screenTermination resistance 150 Ohm
Ordering Information
KAL785 RS485 communications module for KSA702/5 control panels
Industry standard RS485 communications
No hardware configuration required
RS485 communications module for KSA702/5 control panels KAL785
The NC785 RS485 expander allows for an easy upgrade to the KSA701/FP1500series analalogue addressable fire panels. Each module adds an additionalindustry standard RS485 communication port to the panel. This port could beused for communications with other network nodes in the fire panel network.
Technical Data
Number of ports 1Communications medium RS485Technical specifications
Maximum cable length 1200 mCommunication speed 9600 baudCable CAT5 - twisted with screenTermination resistance 150 Ohm
Ordering Information
NC785 RS485 expansion kit for KSA701/FP1500 fire panelsIndustry standard RS485 communications
No hardware configuration required
RS485 expansion kit for KSA701/FP1500 fire panels NC785
Page 20
CO Detection
The KM-Series CO detection system is designed for applications such asvehicle parking areas where concentrations of CO may accumulate. The rangeis compliant with the UNE23.300/84 standard. The KM260/1 is a 1 to 5 zonescontrol units, using KM170 detectors.
Technical Data
Power SupplyMains Supply 230 VAC ±10% 50 HzPower Consumption 95 W (max)
Zone Configuration Zone Input Voltage 10-20 VDC/VACSensitiviy 0-300 ppmCable Requirement 3 core 1.5 mm²Cable Length (max) 350 mNo. of Detectors (max) 15No. of Zones (max) 5
MechanicalHousing (w x h x d) 275 x 335 x 130 mmWeight 6 kg
Ordering Information
KM260/1-ING CO detection control panel - 1 Zone
KM260/2-ING CO detection control panel - 2 Zones
KM260/3-ING CO detection control panel - 3 Zones
KM260/4-ING CO detection control panel - 4 Zones
KM260/5-ING CO detection control panel - 5 Zones
Designed according to norm 23300/84
Miner CDM8001 and CDM8002 standard password
LGAI 154.909 and 96013132 standard certification
Easy to use
Low current consumption
Direct reading of measured levels
Easy installation
Extraction relays and alarm outputs per area
From 1 to 5 areas
3-wire system
Modular design
Up to 15 detectors per zone
10 seconds response time
Elegant design
Supervision of all zone lines
Available in various languages
CO detection control panel - 1 Zone KM260/1-ING
CO detection control panel - 2 Zones KM260/2-ING
CO detection control panel - 3 Zones KM260/3-ING
CO detection control panel - 5 Zones KM260/5-ING
CO detection control panel - 4 Zones KM260/4-ING
Page 21
CO Detection
The KM260 is an expansion module for the KM260-Series CO panels from GE-Interlogix. It allows for an additional monitoring zone to be added to thecontrol panel, each module allowing for an additional 15 sensors to beconnected.
Technical Data
Power SupplyMains Supply 230 VAC ±10% 50 HzPower Consumption 95 W (max)
Zone Configuration Zone Input Voltage 10-20 VDC/VACSensitiviy 0-300 ppmCable Requirement 3 core 1.5 mm²Cable Length (max) 350 mNo. of Detectors (max) 15No. of Zones (max) 1
Ordering Information
KM260-ING CO detection expansion module
Designed according to norm 23300/84
Miner CDM8001 and CDM8002 standard password
LGAI 154.909 and 96013132 standard certification
Easy to use
Low current consumption
Direct reading of measured levels
Easy installation
Extraction relays and alarm outputs per area
3-wire system
Up to 15 detectors per zone
10 seconds response time
Supervision of zone line
Available in various languages
CO detection expansion module KM260-ING
Page 22
CO Detectors
The KM170 detector is specifically designed to react to the presence of carbonmonoxide. The design complies with the requirements of the UNE 23-300standard.
Technical Data
Sensor Type TGS SemicondictorUseful Life 4 yearsElectrical Characteristics
Supply Voltage 10 to 20 VDCQuiescent Current 35 mAReaction Time 10 s
EnvironmentalOperating Temperature 0 to 40 °CProtection Index IP205
MechanicalSize (h x Ø) 81 x 109 mmWeight 115 gMaterial and Colour ABS White
InstallationNumber of detectors per zone 15Covarage 300 m²
Ordering Information
KM170 CO detector with base and mounting supplement
Complies with the requirements of the UNE23-300 standard
Microprocessor based
Resolution of up to 5 ppm
Response time of 10 s
Low current consumption
Local status indication of:
Normal operation
50 ppm detected
Fault
Useful life of up to 4 years
CO detector with base and mounting supplement KM170
Page 23
General
The ASD20 Aspiration Smoke Detector consists of an analysis chamber withone or two smoke detectors, which can be of conventional or analoguetechnology, ionisation or optical. The smoke reaches the analysis chamberthrough the installation pipes after having been sucked in by a turbine insidethe ASD20 system. An electronic circuit controls said turbine and the air flow,giving off a fault signal if the pipes are broken or if the air intake isobstructed. It has two voltagefree relays for local manoeuvres, one perdetector, and a third system fault relay. When analogical smoke detectorsfrom the 700A series are used, it is possible to adjust their sensitivity levelsfrom the fire control unit.
Technical Data
Power supply voltage 24 VConsumption on standby 250 mAConsumption 1st alarm 280 mAConsumption 2nd alarm 320 mAFault consumption 220 mAWorking temperature -10 to +60°CStorage temperature -10 to +70°CRelative humidity <95%Size 314 x 254 x 115Weight 4 kgColour RAL9999Material PolycarbonateCable input 3 x PG11Terminals Base fasteningWire cross-section Max. 1.5 mm²Coverage area per intake 30 m²Maximum num. of intakes 12DIN 8062-type PVC pipes Ø25 mmDetectors Conventional/AnalogueAspiration motor type RadialUseful lifetime of motor 65 000 hours at 40°C
Ordering Information
ASD20 Aspiration Smoke Detector
59000034 Spare filter cartridge for the ASD20.
It can operate with conventional or analogue detectors
Direct connection to the analogue loop
Power supply at 24 VDC
Simple and robust architecture
30 m² coverage per sample intake per sample intake
25 mm PVC piping system
Installation of piping in I-shape and U-shape (symmetrical orassymmetrical)
Continuous supervision of pipe flow volume
Local operation by NO NC relay inside the unit alarm 1, alarm 2and fault
Aspiration Smoke Detector ASD20
Detectors
Page 24
Power Supplies
The FC250 Series is suitable for devices requiring an uninterrupted, regulated24 VDC power supply. The units include a battery charger outlet and anoptional reset facility. The supply is mounted inside a metal casing whichincludes space for two 12 V sealed lead acid batteries.
Technical Data
MechanicalDimensions (w x h x d) 215 x 260 x 75 mmWeight (without batteries) 2.5 kg
ElectricalOperating Voltage 230 VAC 50Hz ±10% Output Voltage 24 VDCBatteries 2 x 12 V 2.1 Ah
EnvironmentalOperating Temperature -10 °C to 40 °CStorage Temperature -10 °C to 40 °CRelative Humidity (Non Condencing) 95% max
Ordering Information
FC251 Power supply unit with battery charger 0.8AFuse protection on both the input and the outputs
Low maintenance
Batteries may be housed internally
Various supply ratings available
Power supply unit with battery charger 0.8A FC251
The FC250 Series is suitable for devices requiring an uninterrupted, regulated24 VDC power supply. The units include a battery charger outlet and anoptional reset facility. The supply is mounted inside a metal casing whichincludes space for two 12 V sealed lead acid batteries.
Technical Data
MechanicalDimensions (w x h x d) 290 x 360 x 110 mmWeight (without batteries) 6.26 kg
ElectricalOperating Voltage 230 VAC 50Hz ±10% Output Voltage 27.6 VDCBatteries 2 x 12 V 6 Ah
EnvironmentalOperating Temperature -10 °C to 40 °CStorageTemperature -10 °C to 40 °CRelative Humidity (Non Condencing) 95% max
Ordering Information
FC252 Power supply unit with battery charger 1.5A
FC253 Power supply unit with battery charger 3A
Fuse protection on both the input and the outputs
Low maintenance
Batteries may be housed internally
Various supply ratings available
Power supply unit with battery charger FC252
Page 25
Fire indicators
The KR24 is specifically designed as an evacuation warning sign for gasextinguising areas. The KR24B has no text on the backlit display, and text maytherefor be added as required for the application. Units supplied with text invarious languages are also availble.
Technical Data
Electrical SpecificationsSupply Voltage 18 to 27 VDCActivation Voltage 18 to 27 VDCCurrent Consumption 600 mASwitching Polarity NAIndicators 24 V 3 W
Environmental SpecificationsWorking Temperature -10 to 75 °C
Physical SpecificationsNumber of zones NABuzzer output 80 dBHousing Colour GreyDisplay Colour RedWeight 700 g
Ordering Information
KR24B Illuminated warning sign (No text) 24VDC
- Low current consumption
- Large angle of view
- Optical and acoustic indications selectable
- Modern and elegant design
Illuminated warning sign (No text) 24VDC KR24B
Page 26
Fire Detectors
Of outstanding performance, efficiency and durability, the 700 series firedetectors are the ideal solution for conventional installations. They aredesigned specifically for use with the Kilsen NKB600, NK600 and NK700 seriesconventional fire panels, but are also compatible with most 3rd party industrystandard conventional control panels.
Technical Data
Operating voltage 18 to 28 VDCCurrent consumption
Quiescent at 24 VDC 30 µAAlarm at 24 VDC < 100 mA
Radio-active source Americium 241Average activity 0.33 +/-0.04µCi (12.1 +/- 1.5 kBq)Remote alarm output < 100 mAHeat specificationOperating temperature -10 to +60 °CStorage temperature -10 to +70 °CHumidity (non-condensing) 0 - 95%IP rating IP205Number of detectors per zone 20Recommended protection resistor 300 ohmDimensions (h x Ø)
Head 45 mm x 99 mmBase 24 mm x 103 mm
Approvals* VdSLPCB
* Check current status with local office
Ordering Information
KL700 Ionisation detector, conventional
Full line consisting of Optical, Ionisation and Heat detectors
An ultra-fine grid prevents the ingress of dust and insects insmoke detectors
Attractive, low-profile design
EN54, LPCB and VdS certification marks (*)
Innovative base compensates for uneven surfaces
Field exchangable optical chamber for ease of maintenance
Ionisation detector, conventional KL700
Page 27
Fire Detectors
Of outstanding performance, efficiency and durability, the 700 series firedetectors are the ideal solution for conventional installations. They aredesigned specifically for use with the Kilsen NKB600, NK600 and NK700 seriesconventional fire panels, but are also compatible with most 3rd party industrystandard conventional control panels.
Technical Data
Operating voltage 18 to 28 VDCCurrent consumption
Quiescent at 24 VDC 70 µAAlarm at 24 VDC < 100 mA
Radio-active sourceAverage activityRemote alarm output < 100 mAHeat specification Max. & ROR to EN54p5Operating temperature -10 to +70 °CStorage temperature -10 to +80 °CHumidity (non-condensing) 0 - 95%IP rating IP205Number of detectors per zone 20Recommended protection resistor 300 ohmDimensions (h x Ø)
Head 45 mm x 99 mmBase 24 mm x 103 mm
Approvals* VdSLPCB
* Check current status with local office
Ordering Information
KL710 Temperature detector (fixed and rate-of-rise), conventional
Full line consisting of Optical, Ionisation and Heat detectors
An ultra-fine grid prevents the ingress of dust and insects insmoke detectors
Attractive, low-profile design
EN54, LPCB and VdS certification marks (*)
Innovative base compensates for uneven surfaces
Field exchangable optical chamber for ease of maintenance
Temperature detector (fixed and rate-of-rise), conventional KL710
Page 28
Fire Detectors
Of outstanding performance, efficiency and durability, the 700 series firedetectors are the ideal solution for conventional installations. They aredesigned specifically for use with the Kilsen NKB600, NK600 and NK700 seriesconventional fire panels, but are also compatible with most 3rd party industrystandard conventional control panels.
Technical Data
Operating voltage 9 to 28 VDCCurrent consumption
Quiescent at 24 VDC 85 µAAlarm at 24 VDC < 100 mA
Radio-active sourceAverage activityRemote alarm output < 100 mAHeat specificationOperating temperature -10 to +70 °C Storage temperature -10 to +70 °CHumidity (non-condensing) 0 - 95%IP rating IP42Number of detectors per zone 20Recommended protection resistor 300 ohmDimensions (h x Ø)
Head 45 mm x 99 mmBase 24 mm x 103 mm
Approvals* EN54*
* Check current status with local office
Ordering Information
KL731 Optical detector, conventional (with field exchangeable optical block)
Full line consisting of Optical, Ionisation and Heat detectors
An ultra-fine grid prevents the ingress of dust and insects insmoke detectors
Attractive, low-profile design
EN54, LPCB and VdS certification marks (*)
Innovative base compensates for uneven surfaces
Field exchangable optical chamber for ease of maintenance
Optical detector, conventional (with field exchangeable optical block) KL731
Page 29
Test and Service Equipment
The KCT731 is a calibration tool to recalibrate the KL731/DP331I conventionaldetectors after replacement of the field exchangeable optical block.
Technical Data
Supply 2 x 9 V batteries
Ordering Information
KCT731 KL731/DP331I Calibration Tool
Easy to use
Simple “go/no-go” function
Battery operated
KL731/DP331I Calibration Tool KCT731
Page 30
Fire Detectors
The KL700A Series uses a microprocessor for measurement andcommunication. An enhanced protocol ensures the overall integrity and errorfree operation of the fire system, without compromising speed. All sensors arecompatible with a standard base that makes them easily interchangeable andthat supports the connection of a remote indicator.
Technical Data
Operating voltage 22 - 38 VDCCurrent consumption
Quiescent @ 38 VDC 200 µAIn Alarm less than 11 mA
Alarm indication (Dual LED) White OFF - Red ONRemote Alarm Output AvailableEnvironment
Storage Temperature -10 °C to +70 °COperating Temperature -10 °C to +60 °CHumidity (non-condensing) 0-95%IP rating IP205
Radioactive Source 0.33 ± 0.04 µCi Am 241Dimensions (h x Ø) 45 mm x 99 mm
Ordering Information
KL700A Analogue addressable ionisation sensor
Remote signalling capabilities
Easy soft addressing (1-125)
SMD technology
Reliable communication protocol
Full diagnostic self testing
Full range: Ionisation, Optical and Heat and Duel sensors(optical/heat)
Full range of supporting I/O units and accessories
EN54 Approved
Analogue addressable ionisation sensor KL700A
Page 31
Fire Detectors
The KL700A Series uses a microprocessor for measurement andcommunication. An enhanced protocol ensures the overall integrity and errorfree operation of the fire system, without compromising speed. All sensors arecompatible with a standard base that makes them easily interchangeable andthat supports the connection of a remote indicator.
Technical Data
Operating voltage 22 - 38 VDCCurrent consumption
Quiescent @ 38 VDC 250 µAIn Alarm less than 11 mA
Alarm indication (Dual LED) White OFF - Red ONRemote Alarm Output AvailableEnvironment
Storage Temperature -10 °C to +80 °COperating Temperature -10 °C to +70 °CHumidity (non-condensing) 0-95%IP rating IP205
Radioactive Source NADimensions (h x Ø) 45 mm x 99 mm
Ordering Information
KL710A Analogue addressable temperature sensor
Remote signalling capabilities
Fixed and Rate-of-Rise heat detectors
Easy soft addressing (1-125)
SMD technology
Reliable communication protocol
Full diagnostic self testing
Full range: Ionisation, Optical and Heat and Duel sensors(optical/heat)
Full range of supporting I/O units and accessories
EN54 Approved
Analogue addressable temperature sensor KL710A
Page 32
Fire Detectors
The KL700A Series uses a microprocessor for measurement andcommunication. An enhanced protocol ensures the overall integrity and errorfree operation of the fire system, without compromising speed. All sensors arecompatible with a standard base that makes them easily interchangeable andthat supports the connection of a remote indicator.
Technical Data
Operating voltage 22 - 38 VDCCurrent consumption
Quiescent @ 38 VDC 350 µAIn Alarm less than 11 mA
Alarm indication (Dual LED) RedRemote Alarm Output AvailableEnvironment
Storage Temperature -10 °C to +70 °COperating Temperature -10 °C to +60 °CHumidity (non-condensing) 0-95%IP rating IP205
Radioactive Source NADimensions (h x Ø) 45 mm x 99 mm
Ordering Information
KL731A Analogue addressable optical sensor (with field exchangeable chamber)
Remote signalling capabilities
Field exchangeable optical chamber
Easy soft addressing (1-125)
SMD technology
Reliable communication protocol
Full diagnostic self testing
Full range: Ionisation, Optical and Heat and Duel sensors(optical/heat)
Full range of supporting I/O units and accessories
EN54 Approved
Black Colour
Analogue addressable optical sensor (with field exchangeable chamber) KL731A
Page 33
Fire Detectors
The KL700A Series uses a microprocessor for measurement andcommunication. An enhanced protocol ensures the overall integrity and errorfree operation of the fire system, without compromising speed. All sensors arecompatible with a standard base that makes them easily interchangeable andthat supports the connection of a remote indicator.
Technical Data
Operating voltage 22 - 38 VDCCurrent consumption
Quiescent @ 38 VDC 350 µAIn Alarm less than 5 mA
Alarm indication (Dual LED) RedRemote Alarm Output AvailableEnvironment
Storage Temperature -10 °C to +70 °COperating Temperature -10 °C to +70 °CHumidity (non-condensing) 0-95%IP rating IP42
Radioactive Source NADimensions (h x Ø) 51 mm x 99 mm
Ordering Information
KL735A Analogue addressable dual (optical and thermal) sensor
Remote signalling capabilities
Fixed and Rate-of-Rise heat detectors
Easy soft addressing (1-125)
SMD technology
Reliable communication protocol
Full diagnostic self testing
Full range: Ionisation, Optical and Heat and Duel sensors(optical/heat)
Full range of supporting I/O units and accessories
EN54 Approved
Analogue addressable dual (optical and thermal) sensor KL735A
Page 34
Accessories
The PG700 is a handheld device programmer and tester for theKL700A/Dx1500 series detectors. It is battery operated and allows the installerto perform installation tasks (such as device addressing) and maintenancetasks (such as device clibration) in the field without external assistance.
Technical Data
Supply 2 x 9 V batteries
Ordering Information
PG700 Fire sensor programmer
Easy to use
Battery operated
4 User selectable programs
- Device analogue value
- Change Device Address
- Sequential device addressing
- KL731A Calibration
Fire sensor programmer PG700
Page 35
Bases
The KZ300 base is designed to be used with the KL300 series detectors fromKilsen.
Technical Data
DimensionsDiameter 107 mmHeight 22 mm
Ordering Information
KZ300 Fire Detector base for KL300 series devices
Polarity sensitive
Remote indicator contact available.
Fire Detector base for KL300 series devices KZ300
The S300 is a base accessory designed for use with the KZ300 detector base.It allows for a surface mount conduit and cable to enter the base from theside. The KZ300 base fits on top of this accessory.
Technical Data
DimensionsDiameter 107 mmHeight 25 mm
Ordering Information
S300 Surface mount supplement for KL300 detectors
Surface mount accessory for KZ300
Surface mount supplement for KL300 detectors S300
Page 36
Bases
The S700 is a base accessory designed for use with the KZ700 series detectorbases. It allows for a surface mount conduit and cable to enter the base fromthe side. The KZ700 series base fits on top of this accessory.
Technical Data
DimensionsDiameter 95 mmHeight 30 mm
Ordering Information
S700 Surface mount accessory for KZ700/DB304 and KZ700 series bases
Surface mount accessory for KZ700 series bases
Surface mount accessory for KZ700/DB304 and KZ700 series bases S700
The KZ705D is a 5 contact universal detector base for use with theKL700/Dx300 series detectors from GE-Interlogix. In addition to the normalbase and remote indication connectors, the KZ705D also has an additionalearth terminal connector to allow for easy terminations of a possible cablescreen. The built in diode is specifically targeted at systems using active end-of-line devices.
Technical Data
Dimensions (Ø x h) 100 x 29 mmOperating VoltageCurrent ConsumptionIsolation CurrentIsolation ResistanceSounder FrequencySound Output
@ 3 mA@ 5 mA
Environmental CharacteristicsOperating Temperature -10 to 70 °CStorage Temperature -10 to 70 °CRelative Humidity (max) 95 % (non-cond.)
Ordering Information
KZ705D Conventional fire detector base with diode
Polarity sensitive
Universal base for conventional detectors
Additional earth terminal available
Remote indicator contact available
Built in diode for active end-of-line systems
Conventional fire detector base with diode KZ705D
Page 37
Bases
The KZ700 is a 4 contact universal detecor base for use with the KL700 andKL700A series detectors from Kilsen. It has the ability to compensate foruneven mounting surfaces.
Technical Data
DimensionsDiameter 104 mmHeight 24 mm
Ordering Information
KZ700 Universal fire detector base (for KL700 and KL700A series detectors)
Polarity sensitive
Universal base fits conventional and analogue detectors
Compensates for uneven surfaces
Remote indicator contact available
EN54 approved
Black Colour
Universal fire detector base (for KL700 and KL700A series detectors) KZ700
The KZ705 is a 5 contact universal detector base for use with theKL700/Dx300 and KL700A/Dx1500 series detectors from GE-Interlogix. Inaddition to the normal base and remote indication connectors, the KZ705 alsohas an additional earth terminal connector to allow for easy terminations of apossible cable screen.
Technical Data
Dimensions (Ø x h) 100 x 29 mmOperating VoltageCurrent ConsumptionIsolation CurrentIsolation ResistanceSounder FrequencySound Output
@ 3 mA@ 5 mA
Environmental CharacteristicsOperating Temperature -10 to 70 °CStorage Temperature -10 to 70 °CRelative Humidity (max) 95 % (non-cond.)
Ordering Information
KZ705 Universal fire detector base with earth connection
Polarity sensitive
Universal base fits conventional and analogue detectors
Additional earth terminal available
Remote indicator contact available
Universal fire detector base with earth connection KZ705
Page 38
Bases
The EOL-ACT is designed for use with the NK700/FP400 fire panels from GE-Interlogix. It is an active end-of-line device to allow the monitoring of aconventional zone through a diode base (such as the KZ705D).
Ordering Information
EOL-ACT Active end-of-line device for use with FP400/KL700 fire panels
Small
Easy to install
Active end-of-line device for use with FP400/KL700 fire panels EOL-ACT
Page 39
Bases
The KZ705R is a 5 contact detector base for use with the KL731/DP331Idetectors from GE-Interlogix. In addition to the normal base and remoteindication connectors, the KZ705R also has an additional earth terminalconnector to allow for easy terminations of a possible cable screen. A built in12 V relay makes it ideal for use on low voltage intrusion systems.
Technical Data
Dimensions (Ø x h) 100 x 29 mmOperating Voltage 12 V ± 10%Current Consumption 12 µAIsolation CurrentIsolation ResistanceSounder FrequencySound Output
@ 3 mA@ 5 mA
Environmental CharacteristicsOperating Temperature -10 to 70 °CStorage Temperature -10 to 70 °CRelative Humidity (max) 95 % (non-cond.)
Ordering Information
KZ705R Conventional fire detector base with relay
Polarity sensitive
12 V relay for 4 wire systems
Additional earth terminal available
Remote indicator contact available
Conventional fire detector base with relay KZ705R
The KZ705I is a detector base with built in isolator for use with theKL700A/Dx1500 series detectors from GE-Interlogix. The isolator protects theloop from short circuit conditions. A LED on the side of the base indicates thestatus of the isolator.
Technical Data
Dimensions (Ø x h) 100 x 29 mmOperating Voltage 17 - 34 VCurrent Consumption 50 µAIsolation Current 6 mAIsolation Resistance 140 MOhmSounder FrequencySound Output
@ 3 mA@ 5 mA
Environmental CharacteristicsOperating Temperature -10 to 70 °CStorage Temperature -10 to 70 °CRelative Humidity (max) 95 % (non-cond.)
Ordering Information
KZ705I Analogue fire detector base with isolator
Polarity sensitive
Universal base for analogue detectors
Additional earth terminal available
Remote indicator contact available
Built in isolator
Analogue fire detector base with isolator KZ705I
Page 40
Bases
The KZ705AS is a detector base with built in analogue addressable sounderfor use with the KL700A/Dx1500 series detectors from GE-Interlogix. Thesounder has its own address on the fire panel loop and works independent ofthe detector. It is fully controlled from the fire panel.
Technical Data
Dimensions (Ø x h) 120 x 58 mmOperating Voltage 22 - 38 VCurrent Consumption 300 µA QuiescentIsolation CurrentIsolation ResistanceSounder Frequency 1 KHzSound Output
@ 3 mA 85 dBA@ 5 mA 95 dBA
Environmental CharacteristicsOperating Temperature -10 to 70 °CStorage Temperature -10 to 70 °CRelative Humidity (max) 95 % (non-cond.)IP Rating IP21c
Ordering Information
KZ705AS Analogue fire detector base with sounder
Polarity sensitive
Universal base for analogue detectors
Additional earth terminal available
Remote indicator contact available
Built in sounder
Up to 90 dBA sound output
Low current consumption
Analogue fire detector base with sounder KZ705AS
Page 41
Bases
The KZ705IAS is a detector base with built in analogue addressable sounderand isolator for use with the KL700A/Dx1500 series detectors from GE-Interlogix. The sounder has its own address on the fire panel loop and worksindependent of the detector. It is fully controlled from the fire panel. Theisolator protects the loop from short circuit conditions.
Technical Data
Dimensions (Ø x h) 120 x 58 mmOperating Voltage 22 - 38 VCurrent Consumption 350 µA QuiescentIsolation Current 6 mAIsolation Resistance 140 MOhmSounder Frequency 1 KHzSound Output
@ 3 mA 85 dBA@ 5 mA 95 dBA
Environmental CharacteristicsOperating Temperature -10 to 70 °CStorage Temperature -10 to 70 °CRelative Humidity (max) 95 % (non-cond.)IP Rating IP21c
Ordering Information
KZ705IAS Analogue fire detector base with isolator and sounder
Polarity sensitive
Universal base for analogue detectors
Additional earth terminal available
Remote indicator contact available
Built in sounder
Up to 90 dBA sound output
Low current consumption
Built in isolator
Analogue fire detector base with isolator and sounder KZ705IAS
Page 42
I/O Modules
Allows the connection of one conventional zone to the analogue fire systemloop. This zone is constantly monitored. Up to 20 conventional devices may beconnected to this zone.
Technical Data
Supply voltage 22-38 VDCCurrent consumption
Quiescent @ 24 V 90 µAQuiescent @ 35 V 105 µAAlarm < 3 mAAux. Supply (24V DC) Quiescent 200 µA + equipAux. Supply (24V DC) Alarm < 85 mA
End-of-line resistor 4.7 kOhmRelay contact rating NAEnvironmental
Storage temperature -10 to +50°COperating temperature -10 to +70°CRelative humidity (non-condensing) 0-95 %
Dimensions (l x w x h) 117 x 80 x 44 mm
Ordering Information
KAL410 Conventional Zone Monitor Unit - 1 ZoneEasy numeric addressing
Continuous supervision of the conventional zones
Surface mount
Local alarm indication
Externally powered
Aesthetically pleasing
Part of a family of I/O modules consisting of:
- Conventional Zone Monitors
- Digital Input Modules
- Extinguishing Control Modules
- Isolator Modules
- Manual Call Points
- Output Units
- Retention Units
- Supervised Output Units for sounder control
Conventional Zone Monitor Unit - 1 Zone KAL410
Page 43
I/O Modules
Allows the connection of four conventional zones to the analogue fire systemloop. These zones are constantly monitored. Up to 20 conventional devicesmay be connected to any zone.
Technical Data
Supply voltage 22-38 VDCCurrent consumption
Quiescent @ 24 V 110 µAQuiescent @ 35 V 135 µAAlarm < 5 mAAux. Supply (24V DC) Quiescent 200 µA + equipAux. Supply (24V DC) Alarm < 360 mA
End-of-line resistor 4.7 kOhmRelay contact rating NAEnvironmental
Storage temperature -10 to +50°COperating temperature -10 to +70°CRelative humidity (non-condensing) 0-95 %
Dimensions (l x w x h) 163 x 107 x 36 mm
Ordering Information
KAL414/4 Conventional Zone Monitor Unit - 4 ZonesEasy numeric addressing
Continuous supervision of the conventional zones
Surface mount
Local alarm indication
Externally powered
Aesthetically pleasing
Part of a family of I/O modules consisting of:
- Conventional Zone Monitors
- Digital Input Modules
- Extinguishing Control Modules
- Isolator Modules
- Manual Call Points
- Output Units
- Retention Units
- Supervised Output Units for sounder control
Conventional Zone Monitor Unit - 4 Zones KAL414/4
Page 44
I/O Modules
The 400 Series modules consists of a complete range of interfaces developedfor input/output control in the KSA700/FP1500 analogue fire systems from GEInterlogix. The KAL426 allows for the connection and control of oneextinguishing area to the addressable fire panel loop.
Technical Data
Supply voltage 22-38 VDCCurrent consumption
Quiescent @ 24 V 110 µAQuiescent @ 35 V 210 µAAlarm < 10 mAAux. Supply (24V DC) Quiescent 120 mAAux. Supply (24V DC) Alarm < 1 A
End-of-line resistor 4.7 kOhmRelay contact rating 2½ AEnvironmental
Storage temperature -10 to +50°COperating temperature -10 to +70°CRelative humidity (non-condensing) 0-95 %
Dimensions (l x w x h) 163 x 107 x 36 mm
Ordering Information
KAL426 Extinguishing Control Module
PK10TD Extinguishing RELEASE MCP with protective cover (Spanish Version)PK10TP Extinguishing INHIBIT MCP with protective cover (Spanish Version)
KR24 Illuminated extinguishing waring sign (Spanish version) 24VDC
SK07 Low consumption multi-tone alarm siren
Aesthetically pleasing
Easy numeric addressing
Externally powered
Normally Open / Normally Closed operation for I/O
Surface mount
Wide range of I/O modules consiting of:
- Conventional Zone Monitors
- Digital Input Modules
- Extinguishing Control Modules
- Isolator Modules
- Manual Call Points
- Output Units
- Retention Units
- Supervised Output Units for sounder control
Extinguishing Control Module KAL426
Page 45
I/O Modules
Provides for one potential free relay output for the fire system loop. Each relayallows for COMMON, NORMALLY OPEN and NORMALLY CLOSED contacts. Theoutput may be used to activate ventilation controls, warning signs, activationof other alarm devices etc. during fire situations.
Technical Data
Supply voltage 22-38 VDCCurrent consumption
Quiescent @ 24 V 70 µAQuiescent @ 35 V 100 µAAlarm < 3.5 mAAux. Supply (24V DC) Quiescent 22 mAAux. Supply (24V DC) Alarm < 50 mA
End-of-line resistor NARelay contact rating 2½A @ 250 VACEnvironmental
Storage temperature -10 to +50°COperating temperature -10 to +70°CRelative humidity (non-condensing) 0-95 %
Dimensions (l x w x h) 117 x 80 x 44 mm
Ordering Information
KAL430 Relay Module - 1 Relay
Easy numeric addressing
Externally powered
Normally open / normally closed operation for I/O
Surface mount
Aesthetically pleasing
Local status indication
Part of a family of I/O modules consiting of:
- Conventional Zone Monitors
- Digital Input Modules
- Extinguishing Control Modules
- Isolator Modules
- Manual Call Points
- Output Units
- Retention Units
- Supervised Output Units for sounder control
Relay Module - 1 Relay KAL430
Page 46
I/O Modules
Allows for the supervision of a single, 24 Volt powered output contact on thefire system loop. This unit may be used to control for e.g. sounders in case offire conditions, but may also be used to switch any output considered crucialenough to have the cable integrity between the unit and the switch pointmonitored.
Technical Data
Supply voltage 22-38 VDCCurrent consumption
Quiescent @ 24 V 110 µAQuiescent @ 35 V 135 µAAlarm < 3.6 mAAux. Supply (24V DC) Quiescent 23 mAAux. Supply (24V DC) Alarm 23 mA + equip
End-of-line resistor 4.7 kOhmRelay contact rating 1¼ A @ 250 VACEnvironmental
Storage temperature -10 to +50°COperating temperature -10 to +70°CRelative humidity (non-condensing) 0-95 %
Dimensions (l x w x h) 117 x 80 x 44 mm
Ordering Information
KAL440 Supervised Relay Module
Easy numeric addressing
Externally powered
Normally open / normally closed operation for I/O
Surface mount
Aesthetically pleasing
Local status indication
Part of a family of I/O modules consiting of:
- Conventional Zone Monitors
- Digital Input Modules
- Extinguishing Control Modules
- Isolator Modules
- Manual Call Points
- Output Units
- Retention Units
- Supervised Output Units for sounder control
Supervised Relay Module KAL440
Page 47
I/O Modules
Provides for four potential free relay outputs for the fire system loop. Eachrelay allows for COMMON, NORMALLY OPEN and NORMALLY CLOSED contacts.The outputs may be used to activate ventilation controls, warning signs,activation of other alarm devices etc. during fire situations.
Technical Data
Supply voltage 22-38 VDCCurrent consumption
Quiescent @ 24 V 110 µAQuiescent @ 35 V 135 µAAlarm 10 mAAux. Supply (24V DC) Quiescent 100 µAAux. Supply (24V DC) Alarm 10 mA
End-of-line resistor NARelay contact rating 2½A @ 250 VACEnvironmental
Storage temperature -10 to +50°COperating temperature -10 to +70°CRelative humidity (non-condensing) 0-95 %
Dimensions (l x w x h) 163 x 107 x 36 mm
Ordering Information
KAL434/4 Relay Module - 4 Relays
Easy numeric addressing
Externally powered
Normally open / normally closed operation for I/O
Surface mount
Aesthetically pleasing
Local status indication
Part of a family of I/O modules consiting of:
- Conventional Zone Monitors
- Digital Input Modules
- Extinguishing Control Modules
- Isolator Modules
- Manual Call Points
- Output Units
- Retention Units
- Supervised Output Units for sounder control
Relay Module - 4 Relays KAL434/4
Page 48
I/O Modules
The 400 Series modules consists of a complete range of interfaces developedfor input/output control in the KSA700/FP1500 analogue fire systems from GEInterlogix. The KAL450 is an addressable manual call point for manual fireactivation.
Technical Data
Supply voltage 22-38 VDCCurrent consumption
Quiescent @ 24 V 90 µAQuiescent @ 35 V 120 µAAlarm < 3.5 mAAux. Supply (24V DC) Quiescent NAAux. Supply (24V DC) Alarm NA
End-of-line resistor NARelay contact rating NAEnvironmental
Storage temperature -10 to +50°COperating temperature -10 to +70°CRelative humidity (non-condensing) 0-95 %
Dimensions (l x w x h) 87 x 87 x 20
Ordering Information
KAL450 Addressable Manual Call Point
KAL450C KAL450 spare glasses (10-pack) (DM711)KAL450E KAL450 accessory for flush mountingKAL450S KAL450 Surface mount back box (DM787)KAL450T KAL450 Anti-tamper plastic cover (DM782)
DM800 Resettable element for MCP DM700/KAL450
Easy numeric addressing
Loop powered
Local test facility
Surface or flush mount
Aesthetically pleasing
Local status indication
Part of a family of I/O modules consiting of:
- Conventional Zone Monitors
- Digital Input Modules
- Extinguishing Control Modules
- Isolator Modules
- Manual Call Points
- Output Units
- Retention Units
- Supervised Output Units for sounder control
Addressable Manual Call Point KAL450
Page 49
Accessories
DM715 spare glasses (10-pack) - replacement glass for manual call point
Ordering Information
DM715 Spare glasses (10-pack)
prEN54 pt11 standard glass
Spare glasses (10-pack) DM715
The KAL450E accessory for flush mounting allows for the KAL450 and PK10manual call points to be flush mounted.
Ordering Information
KAL450E KAL450 accessory for flush mounting
Allows for the KAL450 and PK10 to be flush mounted
KAL450 accessory for flush mounting KAL450E
Page 50
Accessories
The DM787 is an accessory for surface mounting / surface mout back box forthe KAL450 and PK10C manual callpoints. The KAL450C is availble in RED.
Ordering Information
DM787 Surface mount back box
Surface mount back box for MCP - RED
Surface mount back box DM787
The DM782 anti-tamper plastic cover is a protection cover for the KAL450 andPK10 manual call points. It prevents accidental activation of the alarm byenforcing a two step action i.e. lifting the cover, then activating the alarm.
Ordering Information
DM782 Anti-tamper plastic cover
Unobtrusive
Transparent
Protects from accidental alarm activation
Anti-tamper plastic cover DM782
Page 51
I/O Modules
Provides a remote input to the fire system loop. The input is constantlymonitored and its status communicated to the fire control panel. The inputmay be activated by closing or opening a potential free contact, depending onthe module configuration.
This module may be used to monitor any contact by showing its statusthrough the fire control panel e.g. the monitoring of pressure equipment andclosure fire break doors.
Technical Data
Supply voltage 22-38 VDCCurrent consumption
Quiescent @ 24 V 110 µAQuiescent @ 35 V 135 µAAlarm < 10 mAAux. Supply (24V DC) Quiescent 200 µAAux. Supply (24V DC) Alarm < 50 mA
End-of-line resistor NARelay contact rating NAEnvironmental
Storage temperature -10 to +50°COperating temperature -10 to +70°CRelative humidity (non-condensing) 0-95 %
Dimensions (l x w x h) 117 x 80 x 44 mm
Ordering Information
KAL460 Digital Input Module
Easy numeric addressing
Externally powered
Normally open / normally closed operation for I/O
Surface mount
Aesthetically pleasing
Local status indication
Part of a family of I/O modules consiting of:
- Conventional Zone Monitors
- Digital Input Modules
- Extinguishing Control Modules
- Isolator Modules
- Manual Call Points
- Output Units
- Retention Units
- Supervised Output Units for sounder control
Digital Input Module KAL460
Page 52
I/O Modules
The 400 series modules consist of a complete range of interfaces developedfor input/output control in the KSA700/FP1500 analogue fire systems from GEInterlogix. The KAL470 is an isolator module in this series that isolates thefaulty zone on a fire panel loop during short circuit conditions. The KAL470does not use an address on the loop.
Technical Data
Supply voltage 22-38 VDCCurrent consumption
Quiescent @ 24 V 110 µAQuiescent @ 35 V 135 µAAlarm 10 mAAux. Supply (24V DC) Quiescent NAAux. Supply (24V DC) Alarm NA
End-of-line resistor NARelay contact rating NAEnvironmental
Storage temperature -10 to +50°COperating temperature -10 to +50°CRelative humidity (non-condensing) 0-95 %
Dimensions (l x w x h) 75 x 45 x 28 mm
Ordering Information
KAL470 Isolator Module
Requires no device address
Automatic reset
Local status indication
Surface mount
Part of a family of I/O modules consiting of:
- Conventional Zone Monitors
- Digital Input Modules
- Extinguishing Control Modules
- Manual Call Points
- Output Units
- Retention Units
- Supervised Output Units for sounder control
Isolator Module KAL470
Page 53
I/O Modules
Provides a remote input and a potential free voltage relay output to the firesystem loop. The input signal is constantly monitored and its status displayedon the control panel, whilst the output is fail-to-safe. Auxiliary supplymonitoring is also included.
The module is used to for e.g. control and monitor doors such as fire breakdoors. The relay provides the door activation and the input monitors the doorstatus.
Technical Data
Supply voltage 22-38 VDCCurrent consumption
Quiescent @ 24 V 110 µAQuiescent @ 35 V 135 µAAlarm 10 mAAux. Supply (24V DC) Quiescent 200 µAAux. Supply (24V DC) Alarm < 50 mA
End-of-line resistor NARelay contact rating 1A @ 30 VAC/VDCEnvironmental
Storage temperature -10 to +50°COperating temperature -10 to +70°CRelative humidity (non-condensing) 0-95 %
Dimensions (l x w x h) 117 x 80 x 44 mm
Ordering Information
KAL490 Retention Module - 1 Input / 1 Output
Easy numeric addressing
Externally powered
Normally open / normally closed operation for I/O
Surface mount
Aesthetically pleasing
Local status indication
Part of a family of I/O modules consiting of:
- Conventional Zone Monitors
- Digital Input Modules
- Extinguishing Control Modules
- Isolator Modules
- Manual Call Points
- Output Units
- Retention Units
- Supervised Output Units for sounder control
Retention Module - 1 Input / 1 Output KAL490
Page 54
I/O Modules
The SK07A loop powered siren is designed for connection to and control by theKSA700/FP1500 analogue fire detection systems from GE-Interlogix.Communication is done digitally between the fire panel and the sounder.
Technical Data
ElectricalSupply Voltage 22 - 38 VDCQuiescent current 300 µAAlarm current 3 mA @ 85 dBA or less than 20 mA @ 95 dBAMaximum sound level 95 dBA
MechanicalDimensions 63 mm (h) x 93 mm Ø Maximum cable size 2.5 mm²Fastening Screws 2 x 30 mm
EnvironmentalWorking temperature -20 °C to +50 °CStorage temperature -20 °C to +70 °CRelative humidity (maximum) 95 %Protection Index IP445
Ordering Information
SK07A Addressable loop powered sirenEN54 part 3 compliant
Up to 95 dBA sound output
Different alarm tones and sound levels
Low current consumption
Low profile
IP445 protection level
Easy installation
Polarity sensitive
Rear and side cable entry possible
Low and easy maintenance
Addressable loop powered siren SK07A
Page 55
Software
PCC-Config allows easy, menu driven, programming of all the features andsettings of the panel. Common texts can be easily copied to sensors andzones. Programming becomes simple as all settings are displayed for theprogrammers convenience.
Technical Data
Hardware RequirementsCommunication RS232, Modem and/or TCP/IPDisplay VGA or higher resolutionHard Disk 2 GB with 650 MB free spaceKeyboard RequiredPointing Device RequiredPrinter System printer required for printingProcessor 133 MHz or higher Pentium-compatible CPURAM 64 Mb or moreRemovable Media 1.44 Mb stiffy and CD-ROM or DVD drive
Software RequirementsOperating System Windows ‘98 or Windows 2000
Ordering Information
KSP700 PC Interface & Software for up/download configuration for KSA702/5PCC-Config KSA700/FP1500 Configuration software kit
Windows based
Complete external configuration of the installation
Configuration possibilities for single and networked firesystems
Local or remote operation via modem or TCP/IP
Standard RS232 communication
KSA700 Configuration software kit PCC-Config
The PCG-Config series consists of 3 software applications. The individualsoftware formats allows the graphic package to grow with the installation.PCG-Config102 operates with a single panel and allows for the configurationof all devices up to a maximum of two loops.
Technical Data
Hardware RequirementsCommunication RS232, Modem and/or TCP/IPDisplay SVGA or higher resolutionHard Disk 2 GB with 650 MB free spaceKeyboard RequiredPointing Device RequiredPrinter System printer required for printingProcessor 1 GHz or higher Pentium III-compatible CPURAM 256 Mb or moreRemovable Media 1.44 Mb stiffy and CD-ROM or DVD drive
Software RequirementsOperating System Windows ‘98 or Windows 2000
Ordering Information
PCG-Graphic102 Graphic Software for KSA700/FP1500 Fire Systems (1 panel-2 loops)
Bi-directional communication with single panels and networkedfire systems
Local or remote connection via modem or TCP/IP
Large selection of user configurable icons
Visualises device alarms and status of in- and outputs
Event texts retrieval from the panel
Configurator and operator contol levels
Navigation buttons allowed
Event logs with reporting facilities
Basic drawing package included
Imports bmp & drw format graphics
Graphic Software for KSA700 Fire Systems (1 panel-2 loops) PCG-Graphic102
Page 56
Software
The PCG-Config series consists of 3 software applications. The individualsoftware formats allows the graphic package to grow with the installation.PCG-Config105 supports a single panel up to 5 loops.
Technical Data
Hardware RequirementsCommunication RS232, Modem and/or TCP/IPDisplay SVGA or higher resolutionHard Disk 2 GB with 650 MB free spaceKeyboard RequiredPointing Device RequiredPrinter System printer required for printingProcessor 1 GHz or higher Pentium III-compatible CPURAM 256 Mb or moreRemovable Media 1.44 Mb stiffy and CD-ROM or DVD drive
Software RequirementsOperating System Windows ‘98 or Windows 2000
Ordering Information
PCG-Graphic105 Graphic Software for KSA700/FP1500 Fire Systems (1 panel-5 loops)
Bi-directional communication with single panels and networkedfire systems
Local or remote connection via modem or TCP/IP
Large selection of user configurable icons
Visualises device alarms and status of in- and outputs
Event texts retrieval from the panel
Configurator and operator contol levels
Navigation buttons allowed
Event logs with reporting facilities
Basic drawing package included
Imports bmp & drw format graphics
Graphic Software for KSA700 Fire Systems (1 panel-5 loops) PCG-Graphic105
The PCG-Config series consists of 3 software applications. The individualsoftware formats allows the graphic package to grow with the installation.PCG-ConfigNW allows for monitoring on networked systems with multiplepanels.
Technical Data
Hardware RequirementsCommunication RS232, Modem and/or TCP/IPDisplay SVGA or higher resolutionHard Disk 2 GB with 650 MB free spaceKeyboard RequiredPointing Device RequiredPrinter System printer required for printingProcessor 1 GHz or higher Pentium III-compatible CPURAM 256 Mb or moreRemovable Media 1.44 Mb stiffy and CD-ROM or DVD drive
Software RequirementsOperating System Windows ‘98 or Windows 2000
Ordering Information
PCG-GraphicNW Graphic Software for KSA700/FP1500 Fire Systems (multi-panel)
Bi-directional communication with single panels and networkedfire systems
Local or remote connection via modem or TCP/IP
Large selection of user configurable icons
Visualises device alarms and status of in- and outputs
Event texts retrieval from the panel
Configurator and operator contol levels
Navigation buttons allowed
Event logs with reporting facilities
Basic drawing package included
Imports bmp & drw format graphics
Graphic Software for KSA700 Fire Systems (multi-panel) PCG-GraphicNW
Fire Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1Conventional fire alarm panel with 2 zones
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NKB602
. . . . . . . . . . . . . . . . . . . . . . . . .1
Conventional fire alarm panel with 4 zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NKB604 . . . . . . . . . . . . . . . . . . . . . . . . .
2Conventional fire alarm panel with 6 zones
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NKB606
. . . . . . . . . . . . . . . . . . . . . . . . .3
Conventional fire panel with 2 fire alarm zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NK702 . . . . . . . . . . . . . . . . . . . . . . . . . . .
4Conventional fire panel with 4 fire alarm zones
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NK704
. . . . . . . . . . . . . . . . . . . . . . . . . . .5
Conventional fire panel with 8 fire alarm zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NK708 . . . . . . . . . . . . . . . . . . . . . . . . . . .
6Conventional fire panel with 12 fire alarm zones
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NK712
. . . . . . . . . . . . . . . . . . . . . . . . . . .7
Conventional fire panel with 16 fire alarm zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NK716 . . . . . . . . . . . . . . . . . . . . . . . . . . .
8Conventional extinguishing control panel with 3 zones
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NK703
. . . . . . . . . . . . . . . . . . . . . . . . . . .9
Extinguishing Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9Conventional extinguishing control panel with 5 zones
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NK706
. . . . . . . . . . . . . . . . . . . . . . . . . . .10
Relay module, 4 supervised relays for NK700/Fx400 fire panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SB404 . . . . . . . . . . . . . . . . . . . . . . . . . . .
11Relay module, 4 potential free relays for NK700/Fx400 fire panels
. . . . . . . . . . . . . . . . . . . . . . . . . . .RB404
. . . . . . . . . . . . . . . . . . . . . . . . . . .11
Expansion Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11Analogue addressable fire detection panel - 1 loop
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .KSA701/1
. . . . . . . . . . . . . . . . . . . . . . .12
Fire Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12Analogue addressable fire detection panel - 2 loops
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .KSA701/2
. . . . . . . . . . . . . . . . . . . . . . .13
Analogue addressable fire panel (expandable to 5 loops) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
KSA705 . . . . . . . . . . . . . . . . . . . . . . . . .
14Analogue addressable fire panel with printer (expandable to 5 loops)
. . . . . . . . . . . . . . . . . . . . . . .KSA705P
. . . . . . . . . . . . . . . . . . . . . . . .15
KSA700 Series LCD Repeater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
KSA701R . . . . . . . . . . . . . . . . . . . . . . .
16Repeater Panels
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
GSM Modem for Kilsen Fire Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MODGSM . . . . . . . . . . . . . . . . . . . . . . .
17Expansion Modules
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
RS232 communications module for KSA702/5 control panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
KAL732 . . . . . . . . . . . . . . . . . . . . . . . . . .
18Loop driver module for KSA702/705 control panels
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .KAL701
. . . . . . . . . . . . . . . . . . . . . . . . . .18
RS485 expansion kit for KSA701/FP1500 fire panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NC785 . . . . . . . . . . . . . . . . . . . . . . . . . . .
19RS485 communications module for KSA702/5 control panels
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .KAL785
. . . . . . . . . . . . . . . . . . . . . . . . . .19
CO detection control panel - 4 Zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
KM260/4-ING . . . . . . . . . . . . . . . . . .
20CO detection control panel - 5 Zones
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .KM260/5-ING
. . . . . . . . . . . . . . . . . .20
CO detection control panel - 3 Zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
KM260/3-ING . . . . . . . . . . . . . . . . . .
20CO detection control panel - 2 Zones
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .KM260/2-ING
. . . . . . . . . . . . . . . . . .20
CO detection control panel - 1 Zone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
KM260/1-ING . . . . . . . . . . . . . . . . . .
20CO Detection
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
CO detection expansion module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
KM260-ING . . . . . . . . . . . . . . . . . . . .
21CO detector with base and mounting supplement
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .KM170
. . . . . . . . . . . . . . . . . . . . . . . . . .22
Detectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
23Aspiration Smoke Detector
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ASD20
. . . . . . . . . . . . . . . . . . . . . . . . . . .23
Power supply unit with battery charger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FC252 . . . . . . . . . . . . . . . . . . . . . . . . . . .
24Power supply unit with battery charger 0.8A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .FC251
. . . . . . . . . . . . . . . . . . . . . . . . . . .24
Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
24Illuminated warning sign (No text) 24VDC
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .KR24B
. . . . . . . . . . . . . . . . . . . . . . . . . . .25
Fire indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
25Ionisation detector, conventional
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .KL700
. . . . . . . . . . . . . . . . . . . . . . . . . . .26
Fire Detectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
26Temperature detector (fixed and rate-of-rise), conventional
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .KL710
. . . . . . . . . . . . . . . . . . . . . . . . . . .27
Optical detector, conventional (with field exchangeable optical block) . . . . . . . . . . . . . . . . . . . . . . .
KL731 . . . . . . . . . . . . . . . . . . . . . . . . . . .
28KL731/DP331I Calibration Tool
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .KCT731
. . . . . . . . . . . . . . . . . . . . . . . . .29
Test and Service Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
29Analogue addressable ionisation sensor
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .KL700A
. . . . . . . . . . . . . . . . . . . . . . . . . .30
Fire Detectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
30Analogue addressable temperature sensor
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .KL710A
. . . . . . . . . . . . . . . . . . . . . . . . . .31
Analogue addressable optical sensor (with field exchangeable chamber) . . . . . . . . . . . . . . . . . . .
KL731A . . . . . . . . . . . . . . . . . . . . . . . . . .
32Analogue addressable dual (optical and thermal) sensor
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .KL735A
. . . . . . . . . . . . . . . . . . . . . . . . . .33
Fire sensor programmer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PG700 . . . . . . . . . . . . . . . . . . . . . . . . . . .
34Accessories
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
Surface mount supplement for KL300 detectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
S300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
35Fire Detector base for KL300 series devices
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .KZ300
. . . . . . . . . . . . . . . . . . . . . . . . . . .35
Bases . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
35Conventional fire detector base with diode
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .KZ705D
. . . . . . . . . . . . . . . . . . . . . . . . .36
Surface mount accessory for KZ700/DB304 and KZ700 series bases . . . . . . . . . . . . . . . . . . . . . . .
S700 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
36Universal fire detector base with earth connection
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .KZ705
. . . . . . . . . . . . . . . . . . . . . . . . . . .37
Universal fire detector base (for KL700 and KL700A series detectors) . . . . . . . . . . . . . . . . . . . . . .
KZ700 . . . . . . . . . . . . . . . . . . . . . . . . . . .
37Active end-of-line device for use with FP400/KL700 fire panels
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .EOL-ACT
. . . . . . . . . . . . . . . . . . . . . . . .38
Analogue fire detector base with isolator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
KZ705I . . . . . . . . . . . . . . . . . . . . . . . . . .
39Conventional fire detector base with relay
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .KZ705R
. . . . . . . . . . . . . . . . . . . . . . . . .39
Analogue fire detector base with sounder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
KZ705AS . . . . . . . . . . . . . . . . . . . . . . . .
40Analogue fire detector base with isolator and sounder
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .KZ705IAS
. . . . . . . . . . . . . . . . . . . . . . .41
Conventional Zone Monitor Unit - 1 Zone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
KAL410 . . . . . . . . . . . . . . . . . . . . . . . . . .
42I/O Modules
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
Conventional Zone Monitor Unit - 4 Zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
KAL414/4 . . . . . . . . . . . . . . . . . . . . . . .
43Extinguishing Control Module
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .KAL426
. . . . . . . . . . . . . . . . . . . . . . . . . .44
Relay Module - 1 Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
KAL430 . . . . . . . . . . . . . . . . . . . . . . . . . .
45Supervised Relay Module
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .KAL440
. . . . . . . . . . . . . . . . . . . . . . . . . .46
Relay Module - 4 Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
KAL434/4 . . . . . . . . . . . . . . . . . . . . . . .
47Addressable Manual Call Point
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .KAL450
. . . . . . . . . . . . . . . . . . . . . . . . . .48
KAL450 accessory for flush mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
KAL450E . . . . . . . . . . . . . . . . . . . . . . . .
49Spare glasses (10-pack)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .DM715
. . . . . . . . . . . . . . . . . . . . . . . . . .49
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
49Anti-tamper plastic cover
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .DM782
. . . . . . . . . . . . . . . . . . . . . . . . . .50
Surface mount back box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DM787 . . . . . . . . . . . . . . . . . . . . . . . . . .
50Digital Input Module
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .KAL460
. . . . . . . . . . . . . . . . . . . . . . . . . .51
I/O Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
51Isolator Module
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .KAL470
. . . . . . . . . . . . . . . . . . . . . . . . . .52
Retention Module - 1 Input / 1 Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
KAL490 . . . . . . . . . . . . . . . . . . . . . . . . . .
53Addressable loop powered siren
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .SK07A
. . . . . . . . . . . . . . . . . . . . . . . . . . .54
Graphic Software for KSA700 Fire Systems (1 panel-2 loops) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PCG-Graphic102 . . . . . . . . . . . . . .
55KSA700 Configuration software kit
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .PCC-Config
. . . . . . . . . . . . . . . . . . . . .55
Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
55Graphic Software for KSA700 Fire Systems (multi-panel)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .PCG-GraphicNW
. . . . . . . . . . . . . .56
Graphic Software for KSA700 Fire Systems (1 panel-5 loops) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PCG-Graphic105 . . . . . . . . . . . . . .
56