GE PROPRIETARY AND CONFIDENTIAL INFORMATIONapps.geindustrial.com/publibrary/checkout/85C-1005... ·...

7
A 11 12 13 14 15 16 12 13 14 15 16 A B C D C D 1041.5 [41.00] 175.0 [6.89] 130.0 [5.12] 1155.7 [45.50] 3.4 [.14] HINGE 3.4 [.14] HINGE X Y 57.2 [2.25] 82.3 [3.24] 79.0 [3.11] 1386.2 [54.57] 858 [33.8] 770.7 [30.34] 1035.4 [40.76] 1135.4 [44.70] Z 1600.0 [63.00] 22.8 [.90] 22.8 [.90] 1054.1 [41.5] 121.8 [4.80] 50.8 [2.00] 6 X 15.9 .625 [ ] 2286.0 [90.00] 25.4 [1.00] 76.2 [3.00] 101.6 TYP. [4.00] 1103.3 [43.44] 254.0 [10.00] R SOURCE 1 MANUAL CHARGING HANDLE OPERATING RADIUS 273.4 10.76 [ ] R RACKING HANDLE OPERATING RADIUS 273.4 10.76 [ ] R SOURCE 2 MANUAL CHARGING HANDLE OPERATING RADIUS 273.4 10.76 [ ] 485.1 [19.10] 1315.7 [51.80] 95.3 [3.75] 426.7 [16.80] 95.3 [3.75] 426.7 [16.80] 563.9 [22.20] 388.6 [15.30] 485.1 [19.10] 719.9 [28.34] 807.7 [31.80] 1308.9 [51.53] 68.1 [2.68] 431.0 [17.00] SEE NOTE#13 CABLE INSTALLATION 15.3 [.60] 16.8 [.66] 27.9 [1.10] SIDE DOOR 27.9 [1.10] SIDE DOOR 516.5 [20.34] 12.0 [304.8] 22.9 [.90] Q-TURN LATCH TYP. CRITICAL TO QUALITY CHARACTERISTIC FINISH FRACTIONS TOLERANCE ON: 1 PL DECIMALS 2 PL DECIMALS ANGLES UNLESS OTHERWISE SPECIFIED IN DRAWING DIMENSIONS ARE IN MILLIMETERS [INCHES] . APPLIED PRACTICES FOR ADDITIONAL INFO REFER TO: GE PROPRIETARY AND CONFIDENTIAL INFORMATION This document is the property of General Electric Company ("GE") and contains proprietary information of GE. This document is loaned on the express condition that neither it nor the information contained therein shall be disclosed to others without the express written consent of GE Industrial Systems, and that the information shall be used by the recipient only as approved expressly by GE Industrial Systems. This document shall be returned to GE upon its request. This document may be subject to certain restrictions under U.S. export control laws and regulations. SIGNATURES DATE MODEL SS 11/28/12 DETAIL SM 11/28/12 CHECKED SS 11/28/12 ENGRG . . MFG . . QUALITY . . ISSUED . . SOLID MODEL: 85C-1005 REVISIONS REV. DESCRIPTION DATE APPROVED B 70084420 REVISED NOTES; UPDATED GROUND LUG LOCATION 09/27/13 SS C 70084420 COMPRESSION LUG CONFIGURATIONS ADDED 11/08/13 PK Part must conform to SI 900000 Sect. 4 Toxicity Procedure; Sect. 13 RoHS Procedure; Sect. 14 REACH Procedure GE Zenith Controls TITLE BYPASS ISOLATION ATS - NEMA 3R,4,4X,12 1000-3000A, S/D/CT 40LB - 3P/4P/SN, MX250/MX350 SIZE DRAWING REV C 85C-1005 C SCALE: 0.040 REF. No: . SHEET 1 OF 7 THIRD ANGLE PROJECTION SIZE DRAWING NO. REV SHEET C 85C-1005 C 1 ELECTRICAL PANEL FRONT VIEW (FRONT DOOR NOT SHOWN) INSIDE DOOR MINI DOOR [NOT SHOWN] FRONT OF THE ENCLOSURE CONTROLLER CONTROL SWITCH CONTACT RESET RIGHT SIDE VIEW WITH RIGHT SIDE PANEL LEFT SIDE VIEW WITH LEFT SIDE PANEL RIGHT SIDE VIEW WITHOUT RIGHT SIDE PANEL BYPASS ISOLATION SWITCH ATS SOURCE 2 MANUAL CHARGING BYPASS ISOLATION SWITCH HANDLE SOURCE 1 MANUAL CHARGING BYPASS ISOLATION SWITCH HANDLE RACKING INTERFACE FRONT DOOR INSIDE DOOR REAR DOOR GROUND LUG SEE NOTE #8 SOURCE 1 LOAD SOURCE 2 TOP VIEW TOP & BOTTOM CABLE ENTRY SPACE (CUSTOMER TO MODIFY) CONTROL WIRING CONDUIT ENTRY SPACE REFERENCE ONLY (CUSTOMER TO MODIFY) 3/4-10 ACORN NUT FLOOR MOUNTING DETAILS (COMMON FOR 3P & 4P - 1000-3000A) NOTES: 1. 100% RATED SWITCHED NEUTRAL OR SOLID NEUTRAL 2. WIRE BENDING SPACE AND GUTTER SPACE TO MEET UL 1008 AND NEC. WIRE BENDING AND GUTTER SPACE MEASURED AT POINT OF CONNECTION TO LUGS. 3. STANDARD SWITCH CONFIGURATION IS TOP SOURCE 1, MIDDLE LOAD AND BOTTOM SOURCE 2. REVERSE SOURCE CONFIGURATION AVAILABLE AS AN OPTION 4. LUGS (MECHANICAL/COMPRESSION) ARE SUPPLIED AS OPTIONAL ACCESSORY ONLY. CONSULT FACTORY. TYPICAL CONFIGURATION SHOWN FOR REFERANCE ONLY. PRODUCT TO UTILIZE EITHER LONG OR SHORT BARREL COMPRESSION LUGS. 5. LUGS SHOWN FOR TOP CABLE ENTRY. MAY BE REVERSED FOR BOTTOM CABLE ENTRY 6. ALL CABLE ENTRY IN REAR OF CABINET. NO CABLE ENTRY IN FRONT OF CABINET. 7. MAINTAIN ELECTRICAL CLEARANCE OF 25.4 [1.00] MINIMUM BETWEEN LIVE PARTS AND GROUNDED METAL PARTS 8. UNIT SUPPLIED WITH UL/CSA APPROVED MECHANICAL GROUND LUG AS APPLICABLE #4 - 600 MCM (COPPER) FOR ONE CONDUCTOR #1/0 - 250 MCM (COPPER) FOR TWO CONDUCTORS 9. GROUND BAR IS SUPPLIED AS OPTIONAL ONLY 10. HANDLING AND MOVEMENT OF CABINET MUST BE DONE IN THE UPRIGHT POSITION ONLY WITH APPROPRIATE LIFTING EQUIPMENT 11. OPERATING TEMPERATURE RANGE OF THE UNIT IS -20°C TO +65°C STORAGE TEMPARATURE RANGE OF THE UNIT IS -30 C TO +75 C 12. CONSTRUCTION PER UL-1008 13. 914 [36.0] MIN. CLEARANCE SPACE RECOMMENDED FOR ACCESS TO REAR OR BOTH SIDES OF THE UNIT 14. ALL DIMENSIONS ARE FOR REFERENCE ONLY FRONT OF THE ENCLOSURE

Transcript of GE PROPRIETARY AND CONFIDENTIAL INFORMATIONapps.geindustrial.com/publibrary/checkout/85C-1005... ·...

Page 1: GE PROPRIETARY AND CONFIDENTIAL INFORMATIONapps.geindustrial.com/publibrary/checkout/85C-1005... · reset right side view with right side panel left side view with left side panel

A

111213141516

1213141516

A

B

C

D

C

D

1041.5[41.00]

175.0[6.89]

130.0[5.12]

1155.7[45.50]

3.4[.14]HINGE

3.4[.14]HINGE

X

Y

57.2[2.25]

82.3[3.24]

79.0[3.11]

1386.2[54.57]

858[33.8]

770.7[30.34]

1035.4[40.76]

1135.4[44.70]

Z

1600.0[63.00]

22.8[.90]

22.8[.90]

1054.1[41.5]

121.8[4.80]

50.8[2.00]

6 X 15.9.625[ ]

2286.0 [90.00]

25.4[1.00]

76.2[3.00]

101.6 TYP.[4.00]

1103.3[43.44]

254.0[10.00]

R

SOURCE 1 MANUAL CHARGING HANDLE

OPERATING RADIUS

273.410.76[ ]

R

RACKING HANDLEOPERATING RADIUS

273.410.76[ ]

R

SOURCE 2MANUAL CHARGING HANDLE

OPERATING RADIUS

273.410.76[ ]

485.1[19.10]

1315.7[51.80]

95.3[3.75]

426.7[16.80]

95.3[3.75]

426.7[16.80]

563.9[22.20]

388.6[15.30]

485.1[19.10]

719.9[28.34]

807.7[31.80]

1308.9[51.53]

68.1[2.68]

431.0[17.00]

SEE NOTE#13CABLE INSTALLATION

15.3[.60]

16.8[.66]

27.9[1.10]SIDE DOOR

27.9[1.10]

SIDE DOOR

516.5[20.34]12.0

[304.8]

22.9[.90]Q-TURN LATCHTYP.

CRITICAL TO QUALITYCHARACTERISTIC

FINISH

FRACTIONS

TOLERANCE ON:

1 PL DECIMALS

2 PL DECIMALS

ANGLES

UNLESS OTHERWISESPECIFIED IN DRAWING

DIMENSIONS ARE IN MILLIMETERS [INCHES]

.APPLIEDPRACTICES

FOR ADDITIONAL INFO REFER TO:

GE PROPRIETARY AND CONFIDENTIAL INFORMATION

This document is the property of General Electric Company ("GE") and contains proprietary information of GE. This document is loaned on the express condition

that neither it nor the information contained therein shall be disclosed to others without the express written consent of GE Industrial Systems, and that the information shall be used by the recipient only as approved expressly by GE Industrial Systems. This document shall be returned to GE upon its request.

This document may be subject to certain restrictions under U.S. export control laws and regulations.

SIGNATURES DATE

MODEL SS 11/28/12

DETAIL SM 11/28/12

CHECKED SS 11/28/12

ENGRG . .

MFG . .

QUALITY . .

ISSUED . .

SOLID MODEL: 85C-1005

REVISIONS

REV. DESCRIPTION DATE APPROVED

B 70084420 REVISED NOTES; UPDATED GROUND LUG LOCATION 09/27/13 SS

C 70084420 COMPRESSION LUG CONFIGURATIONS ADDED 11/08/13 PK

Part must conform to SI 900000 Sect. 4 Toxicity Procedure; Sect. 13 RoHS Procedure; Sect. 14 REACH Procedure

GE Zenith Controls

TITLE

BYPASS ISOLATION ATS - NEMA 3R,4,4X,121000-3000A, S/D/CT

40LB - 3P/4P/SN, MX250/MX350SIZE DRAWING REV

C 85C-1005 CSCALE: 0.040 REF. No: . SHEET 1 OF 7

THIRD ANGLE PROJECTION

SIZE DRAWING NO. REV SHEET

C 85C-1005 C 1

ELECTRICALPANEL

FRONT VIEW(FRONT DOOR NOT SHOWN)

INSIDE DOOR

MINI DOOR[NOT SHOWN]

FRONT OF THEENCLOSURE

CONTROLLER

CONTROL SWITCH

CONTACTRESET

RIGHT SIDE VIEWWITH RIGHT SIDE PANEL

LEFT SIDE VIEWWITH LEFT SIDE PANEL

RIGHT SIDE VIEWWITHOUT RIGHT SIDE PANEL

BYPASS ISOLATION SWITCH

ATS

SOURCE 2MANUAL

CHARGINGBYPASS

ISOLATIONSWITCH HANDLE

SOURCE 1MANUAL CHARGING

BYPASSISOLATION

SWITCH HANDLE

RACKINGINTERFACE

FRONTDOOR

INSIDEDOOR

REAR DOOR

GROUND LUGSEE NOTE #8

SOURCE 1

LOAD

SOURCE 2

TOP VIEW

TOP & BOTTOM CABLE ENTRY SPACE(CUSTOMER TO MODIFY)

CONTROL WIRINGCONDUIT ENTRY SPACE

REFERENCE ONLY(CUSTOMER TO MODIFY)

3/4-10 ACORN NUT

FLOOR MOUNTING DETAILS(COMMON FOR 3P & 4P - 1000-3000A)

NOTES: 1. 100% RATED SWITCHED NEUTRAL OR SOLID NEUTRAL 2. WIRE BENDING SPACE AND GUTTER SPACE TO MEET UL 1008 AND NEC. WIRE BENDING AND GUTTER SPACE MEASURED AT POINT OF CONNECTION TO LUGS. 3. STANDARD SWITCH CONFIGURATION IS TOP SOURCE 1, MIDDLE LOAD AND BOTTOM SOURCE 2. REVERSE SOURCE CONFIGURATION AVAILABLE AS AN OPTION 4. LUGS (MECHANICAL/COMPRESSION) ARE SUPPLIED AS OPTIONAL ACCESSORY ONLY. CONSULT FACTORY. TYPICAL CONFIGURATION SHOWN FOR REFERANCE ONLY. PRODUCT TO UTILIZE EITHER LONG OR SHORT BARREL COMPRESSION LUGS. 5. LUGS SHOWN FOR TOP CABLE ENTRY. MAY BE REVERSED FOR BOTTOM CABLE ENTRY 6. ALL CABLE ENTRY IN REAR OF CABINET. NO CABLE ENTRY IN FRONT OF CABINET. 7. MAINTAIN ELECTRICAL CLEARANCE OF 25.4 [1.00] MINIMUM BETWEEN LIVE PARTS AND GROUNDED METAL PARTS 8. UNIT SUPPLIED WITH UL/CSA APPROVED MECHANICAL GROUND LUG AS APPLICABLE #4 - 600 MCM (COPPER) FOR ONE CONDUCTOR #1/0 - 250 MCM (COPPER) FOR TWO CONDUCTORS 9. GROUND BAR IS SUPPLIED AS OPTIONAL ONLY10. HANDLING AND MOVEMENT OF CABINET MUST BE DONE IN THE UPRIGHT POSITION ONLY WITH APPROPRIATE LIFTING EQUIPMENT11. OPERATING TEMPERATURE RANGE OF THE UNIT IS -20°C TO +65°C STORAGE TEMPARATURE RANGE OF THE UNIT IS -30 C TO +75 C12. CONSTRUCTION PER UL-100813. 914 [36.0] MIN. CLEARANCE SPACE RECOMMENDED FOR ACCESS TO REAR OR BOTH SIDES OF THE UNIT14. ALL DIMENSIONS ARE FOR REFERENCE ONLY

FRONT OF THEENCLOSURE

Page 2: GE PROPRIETARY AND CONFIDENTIAL INFORMATIONapps.geindustrial.com/publibrary/checkout/85C-1005... · reset right side view with right side panel left side view with left side panel

A

212223242526

2223242526

A

B

C

D

C

D443.6[17.46]

368.6[14.51]

443.6[17.46]

443.6[17.46]

368.6[14.51]

443.6[17.46]

349.1[13.74]

349.1[13.74]

430.9[16.96]

357.6[14.08]

H

K

M

N

R

ST V

H

K

M

N

R

S

VT

861.1[33.90]

1060.1[41.74]

1332.8[52.47]

820.0[32.28]

1092.2[43.00]

1291.6[50.85]

268.5[10.57]

X

Y

Z

GE PROPRIETARY AND CONFIDENTIAL INFORMATION

This document is the property of General Electric Company ("GE") and contains proprietary information of GE. This document is loaned on the express condition

that neither it nor the information contained therein shall be disclosed to others without the express written consent of GE Industrial Systems, and that the information shall be used by the recipient only as approved expressly by GE Industrial Systems. This document shall be returned to GE upon its request.

This document may be subject to certain restrictions under U.S. export control laws and regulations.

SIZE DRAWING NO. REV SHEET

C 85C-1005 C 2

GE Zenith Controls SIZE DRAWING REV.

C 85C-1005MODEL SS 11/28/12 CDETAIL SM 11/28/12 SCALE: 0.050 SHEET 2 OF 7

THIRD ANGLE PROJECTION

WIRE BENDING SPACE

AMPERAGECONTROLLER

TYPEPOLE

LUGRANGE

TOP ENTRY BOTTOM ENTRY WIRE GUTTERS

H K M N R S T(LEFT) V(RIGHT)

1000-2000 A MX 250/3503-POLE COPPER CABLES ONLY

CABLE QTY : 6500-750KCMIL

805.6[31.72]

1060.5[41.75]

1388.3[54.66]

764.4[30.09]

1091.9[42.99]

1346.8[53.02]

499.1[15.71] 392.7

[15.46]4-POLE

268.6[10.57]

TABLE#1 : WEIGHT & COG OF ENCLOSED BYPASS ISOLATION ATS MECHANICAL LUG CONFIGURATION

AMPERAGERATING

POLECENTER OF GRAVITY WEIGHT

KG [LBS]X Y Z

1000-2000 A3-POLE

571[22.5]

1105[43.5]

701[27.6]

1419 *[3128.4]

4-POLE590

[23.2]1106[43.5]

708[27.9]

1507 *[3322.4]

SWITCHED NEUTRAL

RIGHT SIDE VIEW - 4 POLE SWITCH WITH SWITCHED NEUTRAL

REAR VIEW - 4-POLESWITCH WITH SWITCHED NEUTRAL

SOURCE 1

LOAD

SOURCE 2

WIRE BENDING SPACE[TOP ENTRY]

WIRE BENDING SPACE[BOTTOM ENTRY]

S1AS1BS1CS1N

LALBLCLN

S2AS2BS2CS2N

SOLID NEUTRAL

MECHANICAL LUG CONFIGURATION : 1000-2000A

RIGHT SIDE VIEW3-POLE SWITCH

NOTES: 1. * WEIGHT SHOWN IN TABLE #1 INCLUDES WEIGHT OF BYPASS ISOLATION ATS, ENCLOSURE, ELECTRICAL PANEL & LUGS

SOURCE 1

LOAD

SOURCE 2

WIRE BENDING SPACE[TOP ENTRY]

WIRE BENDING SPACE[BOTTOM ENTRY] REAR VIEW

3-POLE SWITCH WITH SOLID NEUTRAL SHOWN

SOLIDNEUTRAL

S1AS1BS1C

LALBLC

S2AS2BS2C

SN

RIGHT SIDE VIEW3-POLE SWITCH [ONLY SOLID NEUTRAL LUGS SHOWN]

SOLIDNEUTRALSHOWN

Page 3: GE PROPRIETARY AND CONFIDENTIAL INFORMATIONapps.geindustrial.com/publibrary/checkout/85C-1005... · reset right side view with right side panel left side view with left side panel

A

313233343536

3233343536

A

B

C

D

C

D

352.6[13.88]

359.5[14.15]

233.6[9.20]

359.5[14.15]

358.3[14.11]

H

KL

M

N

PR

S

T

U

V

W

349.1[13.74]

233.6[9.20]

H

KL

M

P

V

W

359.5[14.15]

358.3[14.11]

359.5[14.15]

N

S

U

T

349.1[13.74]

99.6[3.92]

1191.5[46.91]

1417.2[55.80]

735.6[28.96] 960.9

[37.83]

X

Y

Z

237.0[9.33]POLE 1,2,3 ONLY

376.1[14.81]SN ONLY

WIRE BENDING SPACE

AMPERAGECONTROLLER

TYPEPOLE

LUGRANGE

TOP ENTRY BOTTOM ENTRY WIRE GUTTERS

H K L M N P R S T(LEFT) U(LEFT) V(RIGHT) W(RIGHT)

2600-3000 A MX 250/350

3-POLECOPPER CABLES ONLY

CABLE QTY : 8500-750KCMIL

728.7[28.69]

1015.8[39.99]

1083.0[42.64]

1464.4[57.65]

687.6[27.07]

1069.7[42.12]

-1423.3[56.03]

274.6[10.81]

397.6[15.65]

225.6[8.88]

359.9[14.17]

4-POLE1136.6[44.75]

101.6[4.00]

235.8[9.28]

GE PROPRIETARY AND CONFIDENTIAL INFORMATION

This document is the property of General Electric Company ("GE") and contains proprietary information of GE. This document is loaned on the express condition

that neither it nor the information contained therein shall be disclosed to others without the express written consent of GE Industrial Systems, and that the information shall be used by the recipient only as approved expressly by GE Industrial Systems. This document shall be returned to GE upon its request.

This document may be subject to certain restrictions under U.S. export control laws and regulations.

SIZE DRAWING NO. REV SHEET

C 85C-1005 C 3

GE Zenith Controls SIZE DRAWING REV.

C 85C-1005MODEL SS 11/28/12 CDETAIL SM 11/28/12 SCALE: 0.050 SHEET 3 OF 7

THIRD ANGLE PROJECTION

TABLE#2 : WEIGHT & COG OF ENCLOSED BYPASS ISOLATION ATS MECHANICAL LUG CONFIGURATION

AMPERAGERATING

POLECENTER OF GRAVITY WEIGHT

KG [LBS]X Y Z

2600-3000 A3-POLE

574[22.6]

1107[43.6]

723[28.5]

1474 *[3249]

4-POLE592

[23.3]1107[43.6]

732[28.8]

1584 *[3492]

RIGHT SIDE VIEW - 4 POLE SWITCH WITH SWITCHED NEUTRAL

REAR VIEW - 4 POLESWITCH WITH SWITCHED NEUTRAL

SOURCE 1

LOAD

SOURCE 2

SOLID NEUTRAL

SWITCHED NEUTRAL

WIRE BENDING SPACE[TOP ENTRY]

WIRE BENDING SPACE[BOTTOM ENTRY]

S1AS1BS1CS1N

LALBLC

LN

S2AS2BS2CS2N

NOTES:1. * WEIGHT SHOWN IN TABLE #2 INCLUDES WEIGHT OF BYPASS ISOLATION ATS, ENCLOSURE, ELECTRICAL PANEL & LUGS

MECHANICAL LUG CONFIGURATION : 2600-3000A

RIGHT SIDE VIEW3 POLE SWITCH

RIGHT SIDE VIEW - 3-POLE ONLY SOLID NEUTRAL LUGS SHOWN

REAR VIEW - 3 POLE SWITCH WITH SOLID NEUTRAL SHOWN

SOURCE 1

LOAD

SOURCE 2

WIRE BENDING SPACE[TOP ENTRY]

WIRE BENDING SPACE[BOTTOM ENTRY]

S1AS1BS1C

LA

LBLC

S2AS2BS2C

SN

SOLIDNEUTRAL

SOLID NEUTRALSHOWN

Page 4: GE PROPRIETARY AND CONFIDENTIAL INFORMATIONapps.geindustrial.com/publibrary/checkout/85C-1005... · reset right side view with right side panel left side view with left side panel

A

414243444546

4243444546

A

B

C

D

C

D

347.2[13.67]

208.8[8.22]

347.2[13.67]

347.2[13.67]

208.8[8.22]

347.2[13.67]

349.1[13.74]

349.1[13.74]

H

K

M

N

R

S

T V

X

Y

Z

H

K

955.5[37.62]

M

99.6[3.92]

N

P1190.8[46.88]

S

1411.4[55.57]

734.9[28.93]

347.7[13.69]

U

T V

W

UW

GE PROPRIETARY AND CONFIDENTIAL INFORMATION

This document is the property of General Electric Company ("GE") and contains proprietary information of GE. This document is loaned on the express condition

that neither it nor the information contained therein shall be disclosed to others without the express written consent of GE Industrial Systems, and that the information shall be used by the recipient only as approved expressly by GE Industrial Systems. This document shall be returned to GE upon its request.

This document may be subject to certain restrictions under U.S. export control laws and regulations.

SIZE DRAWING NO. REV SHEET

C 85C-1005 C 4

GE Zenith Controls SIZE DRAWING REV.

C 85C-1005MODEL SS 11/28/12 CDETAIL SM 11/28/12 SCALE: 0.050 SHEET 4 OF 7

THIRD ANGLE PROJECTION

WIRE BENDING SPACE

AMPERAGECONTROLLER

TYPEPOLE

LUGRANGE

TOP ENTRY BOTTOM ENTRY WIRE GUTTERS

H K M N R S T(LEFT) U(LEFT) V(RIGHT) W(RIGHT)

1000-2000 A MX 250/350

3-POLE COPPER CABLES ONLYCABLE QTY : 6500/600/750

KCMIL

775.5[30.53]

1062.2[41.82]

1544.8[60.82]

734.4[28.91]

1217.0[47.91]

1503.7[59.20]

377.7[14.87]

80.0[3.15]

356.9[14.04]

186.9[7.36]

4-POLE247.7[9.75]

77.9[3.07]

TABLE#3 : WEIGHT & COG OF ENCLOSED BYPASS ISOLATION ATS COMPRESSION LUG CONFIGURATION

AMPERAGERATING

POLECENTER OF GRAVITY WEIGHT

KG [LBS]X Y Z

1000-2000 A3-POLE

574[22.6]

1110[43.7]

732[28.8]

1511 *[3331]

4-POLE593

[23.3]1107[43.6]

741[29.2]

1613 *[3556]

NOTES:1. * WEIGHT SHOWN IN TABLE #3 INCLUDES WEIGHT OF BYPASS ISOLATION ATS, ENCLOSURE, ELECTRICAL PANEL & LUGS

SOLID NEUTRAL

SWITCHED NEUTRAL

S1AS1BS1CS1N

LALBLCLN

S2AS2BS2CS2N

S1AS1BS1C

LALBLC

SN

S2AS2BS2C

RIGHT SIDE VIEW - 4-POLESWITCH WITH SWITCHED NEUTRAL

REAR VIEW - 4-POLESWITCH WITH SWITCHED NEUTRAL

SOURCE 1

LOAD

SOURCE 2

WIRE BENDING SPACE[TOP ENTRY]

WIRE BENDING SPACE[BOTTOM ENTRY]

COMPRESSION LUG CONFIGURATION : 1000-2000A

RIGHT SIDE VIEW3-POLE SWITCH

SOURCE 1

LOAD

SOURCE 2

WIRE BENDING SPACE[TOP ENTRY]

WIRE BENDING SPACE[BOTTOM ENTRY] REAR VIEW

3-POLE SWITCH WITH SOLID NEUTRAL SHOWN

SOLIDNEUTRAL

RIGHT SIDE VIEW3-POLE SWITCH [ONLY SOLID NEUTRAL LUGS SHOWN]

SOLIDNEUTRALSHOWN

Page 5: GE PROPRIETARY AND CONFIDENTIAL INFORMATIONapps.geindustrial.com/publibrary/checkout/85C-1005... · reset right side view with right side panel left side view with left side panel

A

515253545556

5253545556

A

B

C

D

C

D

352.6[13.88]

305.2[12.02]

56.7[2.23]

305.2[12.02]

171.5[6.75]

H

K

L

N

P

R

T

U

V

W

H

K

L

P

V

W

N

S

U

T

349.1[13.74]

247.7[9.75]

99.6[3.92]

1190.8[46.88]

1411.4[55.57]

734.9[28.93]

955.5[37.62]

X

Y

Z

305.2[12.02]

56.7[2.23]

305.2[12.02]

WIRE BENDING SPACE

AMPERAGECONTROLLER

TYPEPOLE

LUGRANGE

TOP ENTRY BOTTOM ENTRY WIRE GUTTERS

H K L N P R T(LEFT) U(LEFT) V(RIGHT) W(RIGHT)

2600-3000 A MX 250/350

3-POLE COPPER CABLES ONLYCABLE QTY : 8500/600/750

KCMIL

775.5[30.53]

1061.7[41.80]

1544.8[60.82]

734.4[28.91]

1216.5[47.89]

-77.8[3.06]

196.9[7.75]

288.2[11.35]

407.4[16.04]

4-POLE1503.7[59.20]

101.6[4.00]

235.8[9.28]

GE PROPRIETARY AND CONFIDENTIAL INFORMATION

This document is the property of General Electric Company ("GE") and contains proprietary information of GE. This document is loaned on the express condition

that neither it nor the information contained therein shall be disclosed to others without the express written consent of GE Industrial Systems, and that the information shall be used by the recipient only as approved expressly by GE Industrial Systems. This document shall be returned to GE upon its request.

This document may be subject to certain restrictions under U.S. export control laws and regulations.

SIZE DRAWING NO. REV SHEET

C 85C-1005 C 5

GE Zenith Controls SIZE DRAWING REV.

C 85C-1005MODEL SS 11/28/12 CDETAIL SM 11/28/12 SCALE: 0.050 SHEET 5 OF 7

THIRD ANGLE PROJECTION

TABLE#4 : WEIGHT & COG OF ENCLOSED BYPASS ISOLATION ATS COMPRESSION LUG CONFIGURATION

AMPERAGERATING

POLECENTER OF GRAVITY WEIGHT

KG [LBS]X Y Z

2600-3000 AMP3-POLE

575[22.6]

1111[43.7]

745[29.3]

1541 *[3397]

4-POLE594

[23.4]1108[43.6]

720[28.3]

1644 *[3624]

RIGHT SIDE VIEW - 4-POLESWITCH WITH SWITCHED NEUTRAL

REAR VIEW - 4-POLESWITCH WITH SWITCHED NEUTRAL

SOURCE 1

LOAD

SOURCE 2

NOTES:1. * WEIGHT SHOWN IN TABLE #4 INCLUDES WEIGHT OF BYPASS ISOLATION ATS, ENCLOSURE, ELECTRICAL PANEL & LUGS

SOLID NEUTRAL

SWITCHED NEUTRAL

S1AS1BS1CS1N

LALBLCLN

S2AS2BS2CS2N

S1AS1BS1C

SN

LALBLC

S2AS2BS2C

WIRE BENDING SPACE[TOP ENTRY]

WIRE BENDING SPACE[BOTTOM ENTRY]

COMPRESSION LUG CONFIGURATION : 2600-3000A

RIGHT SIDE VIEW3 POLE SWITCH

RIGHT SIDE VIEW3-POLE SWITCH [ONLY SOLID NEUTRAL LUGS SHOWN]

REAR VIEW3 POLE SWITCH WITH SOLID NEUTRAL SHOWN

SOURCE 1

LOAD

SOURCE 2

WIRE BENDING SPACE[TOP ENTRY]

WIRE BENDING SPACE[BOTTOM ENTRY]

SOLIDNEUTRAL

SOLIDNEUTRALSHOWN

Page 6: GE PROPRIETARY AND CONFIDENTIAL INFORMATIONapps.geindustrial.com/publibrary/checkout/85C-1005... · reset right side view with right side panel left side view with left side panel

A

616263646566

6263646566

A

B

C

D

C

D

595.3[23.44]

1020.1[40.16]

1291.0[50.83]

388.6[15.30]

426.0[16.78]

130.0[5.12]

TYPAa-SOURCE 1

Ca-LOAD

Ba-SOURCE 2

20.0[.79]

101.6[4.00]

351.8[13.85]

95.3[3.75]

22.6[.89]

50.0[1.97]

65.5[2.58]

35.0[1.38]

20.0[.79]

14.0[.55]

67.0[2.64]

65.4[2.57]

71.0[2.80]

201.8[7.94]

426.0[16.78]

Aa-SOURCE 1

Ca-LOAD

Ba-SOURCE 2

518.4[20.41]595.3

[23.44]

1020.1[40.16]

1291.0[50.83]

130.0[5.12]

TYP

4X M10 X 1.5

4X M12 X 1.75

9.5 THICK[.37]

6.35 THICK[.250]

X

Y

Z

47.5[1.87]

33.5[1.32]

15.3[.60]

71.0[2.80]

2X 12.6.50[ ]

130.7[5.15]

101.6[4.00]

20.0[.79]

50.0[1.97]

70.0[2.76]

15.8[.62]

4X 12.6.50[ ]

25.0[.98]

27.0[1.06]

35.0[1.38]

28.4[1.12]

35.0[1.38]

47.5[1.87]

4X 10.5.41[ ]

41.2[1.62]

70.0[2.76]

20.0[.79]

50.0[1.97]

115.0[4.53]

152.4[6.00]

4X 12.6.50[ ]

AMPERAGECONTROLLER

TYPEAa[SOURCE 1] Ba[SOURCE 2] Ca[LOAD]

1000-3000 A MX 250/350522.2

[20.55]522.2[20.55]

545.2[21.46]

TABLE # 5 : WEIGHT & COG OF ENCLOSED BYPASS ISOLATION ATS REAR BUS OPTION

AMPERAGERATING

POLECENTER OF GRAVITY WEIGHT

KG [LBS]X Y Z

1000-3000 A3-POLE

569[22.4]

1105[43.5]

695[27.4]

1392 *[3069]

4-POLE587

[23.1]1106[43.5]

702[27.6]

1491 *[3287]

GE PROPRIETARY AND CONFIDENTIAL INFORMATION

This document is the property of General Electric Company ("GE") and contains proprietary information of GE. This document is loaned on the express condition

that neither it nor the information contained therein shall be disclosed to others without the express written consent of GE Industrial Systems, and that the information shall be used by the recipient only as approved expressly by GE Industrial Systems. This document shall be returned to GE upon its request.

This document may be subject to certain restrictions under U.S. export control laws and regulations.

SIZE DRAWING NO. REV SHEET

C 85C-1005 C 6

GE Zenith Controls SIZE DRAWING REV.

C 85C-1005MODEL SS 11/28/12 CDETAIL SM 11/28/12 SCALE: 0.050 SHEET 6 OF 7

THIRD ANGLE PROJECTION

RUNBACK DETAILS

RECOMMENDED LINE RUNBACK (NOT SUPPLIED)

S1AS1BS1CS1N

LALBLCLN

S2AS2BS2CS2N

BUS MOUNTINGPANEL

SOURCE 1SOURCE 2

1000-3000A BUS DETAILS

BUS MOUNTINGPANEL

LOAD

1. CUSTOMER TO MODIFY ENCLOSURE TO MEET BUS DESIGN CRITERIA2. * WEIGHT SHOWN IN TABLE # 5 INCLUDES WEIGHT OF BYPASS ISOLATION ATS, ENCLOSURE & ELECTRICAL PANEL

RIGHT SIDE VIEW4-POLE SWITCH

REAR VIEW4-POLE SWITCH

REAR BUS RUN BACKS(NOT SUPPLIED)

RECOMMENDED LOAD RUNBACK (NOT SUPPLIED)

1000-3000A REAR BUS OPTION

RIGHT SIDE VIEW3-POLE SWITCH

REAR VIEW3-POLE SWITCH

N3 N2 N1

L1L2L3

E1E2E3

MATERIAL: SILVER FLASH COPPERQTY REQUIRED: 8 FOR 4 POLE, 6 FOR 3 POLE

SCALE 0.250

MATERIAL: SILVER FLASH COPPERQTY REQUIRED: 16 FOR 4 POLE, 12 FOR 3 POLE

SCALE 0.250

Page 7: GE PROPRIETARY AND CONFIDENTIAL INFORMATIONapps.geindustrial.com/publibrary/checkout/85C-1005... · reset right side view with right side panel left side view with left side panel

A

717273747576

7273747576

A

B

C

D

C

D

510.0[20.08]

1096.0[43.15]

598.0[23.54]

72.6[2.86]

566.5[22.30]

216.8[8.54]

22.0[.87]

Xa

Ya

243.4[9.58]

Za

40.2[1.58]

GE PROPRIETARY AND CONFIDENTIAL INFORMATION

This document is the property of General Electric Company ("GE") and contains proprietary information of GE. This document is loaned on the express condition

that neither it nor the information contained therein shall be disclosed to others without the express written consent of GE Industrial Systems, and that the information shall be used by the recipient only as approved expressly by GE Industrial Systems. This document shall be returned to GE upon its request.

This document may be subject to certain restrictions under U.S. export control laws and regulations.

SIZE DRAWING NO. REV SHEET

C 85C-1005 C 7

GE Zenith Controls SIZE DRAWING REV.

C 85C-1005MODEL SS 11/28/12 CDETAIL SM 11/28/12 SCALE: 0.050 SHEET 7 OF 7

THIRD ANGLE PROJECTION

TABLE # 6 : WEIGHT & COG OF ATS

AMPERAGERATING

POLECENTER OF GRAVITY WEIGHT

KG [LBS]Xa Ya Za

1000-3000A

3 POLE260.9

[10.27]560.3[22.06]

311.5[12.26]

239 *[527]

4 POLE270.0

[10.63]559.6[22.03]

277.7[10.93]

280 *[617]

NOTES:1. USE SPREADER BAR FOR REMOVING ATS OUT OF ENCLOSURE. SPREADER BAR NOT SUPPLIED WITH UNIT2. * WEIGHT SHOWN IN TABLE # 6 IS OF ATS

ATS SHOWN OUTSIDE THE ENCLOSURE(FRONT DOOR NOT SHOWN)

ATSLIFTING HOLES 25.0 [.98]