GE Auxiliary · PDF fileGE Auxiliary Turbines 755 MW Cross Compound-Turbines Upgraded to...
Transcript of GE Auxiliary · PDF fileGE Auxiliary Turbines 755 MW Cross Compound-Turbines Upgraded to...
![Page 1: GE Auxiliary · PDF fileGE Auxiliary Turbines 755 MW Cross Compound-Turbines Upgraded to 790MW ... Four identical De Leval steam turbines and one lube oil console and accessories](https://reader031.fdocuments.net/reader031/viewer/2022030501/5aadfa707f8b9a07498b7971/html5/thumbnails/1.jpg)
GE Auxiliary Turbines755 MW Cross Compound-TurbinesUpgraded to 790MW
Mohave Generating StationUnits 1 & 2
Southern California ValveJR Bullard - President - California OperationsPhone (Santa Fe Springs, CA): 562.404.2246Email: [email protected]
Sid McCarra - President - Texas OperationsPhone (Houston, TX): 281.482.4728Email: [email protected]
For more information, please visitwww.scvturbines.weebly.com
![Page 2: GE Auxiliary · PDF fileGE Auxiliary Turbines 755 MW Cross Compound-Turbines Upgraded to 790MW ... Four identical De Leval steam turbines and one lube oil console and accessories](https://reader031.fdocuments.net/reader031/viewer/2022030501/5aadfa707f8b9a07498b7971/html5/thumbnails/2.jpg)
General InformationDe Laval
Equipment FurnishedFour identical De Leval steam turbines and one lube oil console and accessories necessary for safe and efficient operation of unit. All in excellent condition.
Design CharacteristicsThe design characteristics of the De Laval turbines and gear units are tabulated below.
TurbineManufacturer’s Class ...................................................................................................................LJDFType ....................................................................................................................................... MultistageOutput, BHP ................................................................................................................................18,850Speed, RPM ................................................................................................................................... 5,580Rotation ......................................................... Counterclockwise in direction of steam flowCritical Speed, RPM .................................................................................................................... 3,900Steam Inlet Pressure, PSIA ..........................................................................................................177Steam Inlet Temperature, FTT .............................................................................................1398.9Exhaust Pressure, In. Hg. Abs. ......................................................................................................3.0Overspeed Trip at, RPM ................................................................................................. 5910-6026
![Page 3: GE Auxiliary · PDF fileGE Auxiliary Turbines 755 MW Cross Compound-Turbines Upgraded to 790MW ... Four identical De Leval steam turbines and one lube oil console and accessories](https://reader031.fdocuments.net/reader031/viewer/2022030501/5aadfa707f8b9a07498b7971/html5/thumbnails/3.jpg)
Steam chest
Lower shell
![Page 4: GE Auxiliary · PDF fileGE Auxiliary Turbines 755 MW Cross Compound-Turbines Upgraded to 790MW ... Four identical De Leval steam turbines and one lube oil console and accessories](https://reader031.fdocuments.net/reader031/viewer/2022030501/5aadfa707f8b9a07498b7971/html5/thumbnails/4.jpg)
Lower shell
Lower shell
![Page 5: GE Auxiliary · PDF fileGE Auxiliary Turbines 755 MW Cross Compound-Turbines Upgraded to 790MW ... Four identical De Leval steam turbines and one lube oil console and accessories](https://reader031.fdocuments.net/reader031/viewer/2022030501/5aadfa707f8b9a07498b7971/html5/thumbnails/5.jpg)
Steam chest & exhaust port
Auxiliary rotors
![Page 6: GE Auxiliary · PDF fileGE Auxiliary Turbines 755 MW Cross Compound-Turbines Upgraded to 790MW ... Four identical De Leval steam turbines and one lube oil console and accessories](https://reader031.fdocuments.net/reader031/viewer/2022030501/5aadfa707f8b9a07498b7971/html5/thumbnails/6.jpg)
Auxiliary rotor kept wrapped and stored
Auxiliary rotor kept wrapped and stored
![Page 7: GE Auxiliary · PDF fileGE Auxiliary Turbines 755 MW Cross Compound-Turbines Upgraded to 790MW ... Four identical De Leval steam turbines and one lube oil console and accessories](https://reader031.fdocuments.net/reader031/viewer/2022030501/5aadfa707f8b9a07498b7971/html5/thumbnails/7.jpg)
Auxiliary rotor bearing surfaces
Auxiliary rotor bearing surfaces
![Page 8: GE Auxiliary · PDF fileGE Auxiliary Turbines 755 MW Cross Compound-Turbines Upgraded to 790MW ... Four identical De Leval steam turbines and one lube oil console and accessories](https://reader031.fdocuments.net/reader031/viewer/2022030501/5aadfa707f8b9a07498b7971/html5/thumbnails/8.jpg)
Main hydraulic control skid
Steam chest cam assembly
![Page 9: GE Auxiliary · PDF fileGE Auxiliary Turbines 755 MW Cross Compound-Turbines Upgraded to 790MW ... Four identical De Leval steam turbines and one lube oil console and accessories](https://reader031.fdocuments.net/reader031/viewer/2022030501/5aadfa707f8b9a07498b7971/html5/thumbnails/9.jpg)
Hydrogen tanks
Auxiliary turbine control box
![Page 10: GE Auxiliary · PDF fileGE Auxiliary Turbines 755 MW Cross Compound-Turbines Upgraded to 790MW ... Four identical De Leval steam turbines and one lube oil console and accessories](https://reader031.fdocuments.net/reader031/viewer/2022030501/5aadfa707f8b9a07498b7971/html5/thumbnails/10.jpg)
Control valve emergency cut off unit
Byron Jackson boiler feed pump
![Page 11: GE Auxiliary · PDF fileGE Auxiliary Turbines 755 MW Cross Compound-Turbines Upgraded to 790MW ... Four identical De Leval steam turbines and one lube oil console and accessories](https://reader031.fdocuments.net/reader031/viewer/2022030501/5aadfa707f8b9a07498b7971/html5/thumbnails/11.jpg)
Turbine warehouse facility
Auxiliary turbine steam chest - QTY: 4
![Page 12: GE Auxiliary · PDF fileGE Auxiliary Turbines 755 MW Cross Compound-Turbines Upgraded to 790MW ... Four identical De Leval steam turbines and one lube oil console and accessories](https://reader031.fdocuments.net/reader031/viewer/2022030501/5aadfa707f8b9a07498b7971/html5/thumbnails/12.jpg)
Auxiliary units at Laughlin, NV storage
Byron Jackson feed pumps at Laughlin, NV storage - QTY - 4
![Page 13: GE Auxiliary · PDF fileGE Auxiliary Turbines 755 MW Cross Compound-Turbines Upgraded to 790MW ... Four identical De Leval steam turbines and one lube oil console and accessories](https://reader031.fdocuments.net/reader031/viewer/2022030501/5aadfa707f8b9a07498b7971/html5/thumbnails/13.jpg)
Woodward hydraulic skid
Auxiliary rotor blades
![Page 14: GE Auxiliary · PDF fileGE Auxiliary Turbines 755 MW Cross Compound-Turbines Upgraded to 790MW ... Four identical De Leval steam turbines and one lube oil console and accessories](https://reader031.fdocuments.net/reader031/viewer/2022030501/5aadfa707f8b9a07498b7971/html5/thumbnails/14.jpg)
Safety valves
Emergency shutoff-off valve
![Page 15: GE Auxiliary · PDF fileGE Auxiliary Turbines 755 MW Cross Compound-Turbines Upgraded to 790MW ... Four identical De Leval steam turbines and one lube oil console and accessories](https://reader031.fdocuments.net/reader031/viewer/2022030501/5aadfa707f8b9a07498b7971/html5/thumbnails/15.jpg)
Auxiliary turbine lower steam chest - QTY: 4
Byron Jackson boiler feed pump I.D. plate
![Page 16: GE Auxiliary · PDF fileGE Auxiliary Turbines 755 MW Cross Compound-Turbines Upgraded to 790MW ... Four identical De Leval steam turbines and one lube oil console and accessories](https://reader031.fdocuments.net/reader031/viewer/2022030501/5aadfa707f8b9a07498b7971/html5/thumbnails/16.jpg)
Southern California Valve
JR Bullard, President - California OperationsPhone (Santa Fe Springs, CA): 562.404.2246
Email: [email protected]
Sid McCarra, President - Texas OperationsPhone (Houston, TX): 281.482.4728
Email: [email protected]
For more information, please visitwww.scvturbines.weebly.com
SCV_AT_012516