Answers for energy. Performance Enhancement – Gas Turbine Wet Compression pump skid Our top priority at Siemens Energy is to provide outstand- ing, responsive service solutions to help you improve your operating plant competitiveness and profitability. As part of our ongoing commitment to meet the changing requirements of your operating assets, we offer the latest technology to help to enhance your operating plant capabil- ity and flexibility as part of Siemens Flex-Power Services TM . One of our modernization products is Wet Compression. Our product Wet Compression has been a reliable and proven method of injecting water into the gas turbine inlet. Wet Compres- sion is perfectly suited for upgrading peak load machines. A power increase can help you take fuller advantage of high peak load electricity prices and therefore offers attractive financial payback options. Wet Compression is designed to increase the power output of the gas turbine by reducing compressor inlet temperatures, intercooling the compressor and increasing mass flow throughout the turbine. The Wet Compression provides significant performance advantages and offers attractive financial payback options. Your benefits Wet Compression can be an effective system for recovering power loss experienced at high ambient temperature. The mutual occurrence of peak load electricity demand and high ambient temperature can make Wet Compression more beneficial and economical and technical valuable. Aspects of Flex-Power Services ™ Minimum Part Load Maintenance Flexibility Grid Services Power on Demand Minimum Part Load Lo P e a k P o w e r & L o a d G r a d i e n ts E m is s i o n s S t a r t & S t o p P e rf o r m a n c e I n t e r v a ls & C o o l D o w n E m i s s i o n s I n t e r v a l s & C o o l D o w n Maintenance ten Flexibility Power on er Demand S t a r t & S t o p P e r f o r m a n c e Flex-Power Services TM Gas Turbine Wet Compression Modernization 258_130568_Wet_Compression_US.indd 1 02.09.13 12:24

Transcript of Gas Turbine Wet Compression Modernization HR (EN)...Answers for energy. Performance Enhancement –...

Page 1: Gas Turbine Wet Compression Modernization HR (EN)...Answers for energy. Performance Enhancement – Gas Turbine Wet Compression pump skid Our top priority at Siemens Energy is to provide

Answers for energy.

Performance Enhancement – Gas Turbine

Wet Compression pump skid

Our top priority at Siemens Energy is to provide outstand-ing, responsive service solutions to help you improve your operating plant competitiveness and profitability.

As part of our ongoing commitment to meet the changing requirements of your operating assets, we offer the latest technology to help to enhance your operating plant capabil-ity and flexibility as part of Siemens Flex-Power ServicesTM. One of our modernization products is Wet Compression.

Our productWet Compression has been a reliable and proven method of injecting water into the gas turbine inlet. Wet Compres-sion is perfectly suited for upgrading peak load machines. A power increase can help you take fuller advantage of high peak load electricity prices and therefore offers attractive financial payback options. Wet Compression is designed to increase the power output of the gas turbine by reducing compressor inlet temperatures, intercooling the compressor and increasing mass flow throughout the turbine.

The Wet Compression provides significant performance advantages and offers attractive financial payback options.

Your benefitsWet Compression can be an effective system for recovering power loss experienced at high ambient temperature. The mutual occurrence of peak load electricity demand and high ambient temperature can make Wet Compression more beneficial and economical and technical valuable.

Aspects of Flex-Power Services ™

Minim

um

Part Load

Main

tenance

Flexib

ility

Grid

Service

s

Power on

Demand

Minim

um

Part LoadLo

Peak

Pow

er &

Load Gradients Emissions

Start & Stop Performance In

tervals & C

ool D

own

Emissions

Intervals&

CoolD

own

Main

tenance

ten

Flexib

ility

Power on

er

Demand

Start&

Stop

Performance

2

Flex-Power ServicesTM

Gas Turbine Wet Compression Modernization

258_130568_Wet_Compression_US.indd 1 02.09.13 12:24

Page 2: Gas Turbine Wet Compression Modernization HR (EN)...Answers for energy. Performance Enhancement – Gas Turbine Wet Compression pump skid Our top priority at Siemens Energy is to provide

siemens.com/energy

Published by and copyright © 2013:Siemens AGEnergy SectorFreyeslebenstrasse 191058 Erlangen, Germany

Siemens Energy, Inc.4400 Alafaya TrailOrlando, FL 32826, USA

For more information, please contact our Customer Support Center. Phone: +49 180/524 70 00 (Charges depending on provider) E-mail: [email protected]

Energy Service DivisionOrder No. E50001-G520-A156-V2-4A00 Printed in GermanyDispo 34805, c4bs No. 7816TH 258-130568 WÜ DB 461407 08130.5

All rights reserved.Trademarks mentioned in this documentare the property of Siemens AG, its affiliates,or their respective owners.

Subject to change without prior notice.The information in this document containsgeneral descriptions of the technical optionsavailable, which may not apply in all cases.The required technical options should therefore be specified in the contract.

Benefits can include:■■ Power increase of up to 25 MW, depending on the frame and operational requirements*

■■ Up to 3 % gas turbine heat rate im-provement, depending on the frame*

■■ Higher exhaust energy for increased steam production

■■ Greater operational flexibility.

These benefits can lead to the ability to produce more power in peaking and base load operation.

Wet Compression is designed to be large-ly independent of the ambient relative humidity. While somewhat higher perfor-mance improvement can be available in a very hot dry climate, Wet Compression can also be effective at times of high humidity. Wet Compression is applicable for the following frames:■■ SGT5-2000E (V94.2)■■ SGT6-2000E (V84.2)■■ SGT6-3000E (W501D5A)■■ SGT5-4000F (V94.3A)■■ SGT6-4000F (V84.3A)■■ SGT6-5000F (W501F-FC+)

Scope of supplyBesides a comprehensive original equip-ment manufacturer assessment of the gas turbine and the involved power plant components, the scope of this modern-ization includes:■■ Compressor inlet Wet Compression water distribution system with nozzles

■■ Inlet duct treatment■■ Wet Compression pump skid■■ Piping between pump skid and distribution system

■■ Compressor coating*

■■ Compressor upgrade*■■ Modification of existing control logic■■ Gas turbine customization (e.g. axial trust compensation and compressor drains where applicable)

Installation and commissioning of Wet Compression can require from one to three weeks depending on plant and gas turbine configuration. We offer a full range of field service capabilities to help you manage your maintenance and outage schedules.

ReferencesMore than 45 Wet Compression systems are on various frame types in operation worldwide.

Examples include**:■■ More than 35 units in the Americas■■ Two units in Egypt■■ Two units in Australia■■ Eight units in the United Arab Emirates

Typical Gas Turbine Wet Compression Power Augmentation Curve

Wet Compression

With evapcooler

Dry conditionIs

o p

ow

er

ou

tpu

t, M

W

Ambient temperature

We provide products and services to support your goal of maximizing your return on investment.

* Depending on site specific conditions** As of June 2013

Wet Compression nozzle

258_130568_Wet_Compression_US.indd 2 02.09.13 12:24