Gas Power Systems Energy Efficient CHP Solutions for ... · PDF fileGas Power Systems Energy...
Transcript of Gas Power Systems Energy Efficient CHP Solutions for ... · PDF fileGas Power Systems Energy...
![Page 1: Gas Power Systems Energy Efficient CHP Solutions for ... · PDF fileGas Power Systems Energy Efficient CHP Solutions for Commercial and Large-scale Residential Buildings ... 100% of](https://reader031.fdocuments.net/reader031/viewer/2022030405/5a7b1acb7f8b9a0a668bc961/html5/thumbnails/1.jpg)
Gas Power SystemsEnergy Efficient CHP Solutions for Commercial and Large-scale Residential Buildings
Los Angeles, 2009 March 10John Ferraro Building
Stefan Kohler - MTU Onsite Energy GmbH
![Page 2: Gas Power Systems Energy Efficient CHP Solutions for ... · PDF fileGas Power Systems Energy Efficient CHP Solutions for Commercial and Large-scale Residential Buildings ... 100% of](https://reader031.fdocuments.net/reader031/viewer/2022030405/5a7b1acb7f8b9a0a668bc961/html5/thumbnails/2.jpg)
ONSITE ENERGY GAS POWER SYSTEMS COMPANY PROFILE
Page 2 / 3/16/2009
![Page 3: Gas Power Systems Energy Efficient CHP Solutions for ... · PDF fileGas Power Systems Energy Efficient CHP Solutions for Commercial and Large-scale Residential Buildings ... 100% of](https://reader031.fdocuments.net/reader031/viewer/2022030405/5a7b1acb7f8b9a0a668bc961/html5/thumbnails/3.jpg)
STRONG BRANDS AND COMPANIES
Brands
Page 3 / 3/16/2009
Products
Fuel Cells Systems
Injection systems
Propeller shafts
Diesel Engine Systems
Gas Engine Systems
![Page 4: Gas Power Systems Energy Efficient CHP Solutions for ... · PDF fileGas Power Systems Energy Efficient CHP Solutions for Commercial and Large-scale Residential Buildings ... 100% of](https://reader031.fdocuments.net/reader031/viewer/2022030405/5a7b1acb7f8b9a0a668bc961/html5/thumbnails/4.jpg)
COMPANY PROFILEFACTS AND FIGURES
� Germany‘s Market Leader in Cogeneration-Plants in the power range of 100 KW to 2.2 MW
� Founded in 1977
Page 4 / 3/16/2009
� Founded in 1977
� More than 2200 cogeneration modules installed worldwide
� More than 4000 gas engines delivered worldwide
![Page 5: Gas Power Systems Energy Efficient CHP Solutions for ... · PDF fileGas Power Systems Energy Efficient CHP Solutions for Commercial and Large-scale Residential Buildings ... 100% of](https://reader031.fdocuments.net/reader031/viewer/2022030405/5a7b1acb7f8b9a0a668bc961/html5/thumbnails/5.jpg)
COMPANY PROFILEFACTS AND FIGURES
Our way to TOGNUM
1998 – MAN sold company to private owners
2000 – MDE moves into new premises
2002 – Cooperation with MTU Friedrichshafen GmbH (33 % shareholding)
2006 – 100% of MDE shares acquired by MTUFriedrichshafen, MDE is now a Tognum GroupCompany
2007 – Extenstion of assembly hall, office building and testbeds
Page 5 / 3/16/2009
2007 – Extenstion of assembly hall, office building and testbeds
2008 – MDE becomes MTU Onsite Energy GmbHin September 2008
120 kW Cogeneration Plant atMTU’s OG Augsburg office complex
Commercial figures
2005 2006 2007 2008
Turnover 31.5 38.7 62.3 57.3
Investments 1.0 2.4 4.5 2.6
Employees 134 168 209 213
![Page 6: Gas Power Systems Energy Efficient CHP Solutions for ... · PDF fileGas Power Systems Energy Efficient CHP Solutions for Commercial and Large-scale Residential Buildings ... 100% of](https://reader031.fdocuments.net/reader031/viewer/2022030405/5a7b1acb7f8b9a0a668bc961/html5/thumbnails/6.jpg)
COMPANY PROFILETESTING FACILITIES R & D
Page 6 / 3/16/2009
Premium Products by ISO 9001 Certification
� Every engine factory tested according to ISO-standards
� Every module factory tested according to ISO-standards
� Eight test beds with a performance range up to 3.200 kVA
� Separate test beds for research & development
� In-house gas engine specific research & development
� State-of-the-art combustion technology since 1977
![Page 7: Gas Power Systems Energy Efficient CHP Solutions for ... · PDF fileGas Power Systems Energy Efficient CHP Solutions for Commercial and Large-scale Residential Buildings ... 100% of](https://reader031.fdocuments.net/reader031/viewer/2022030405/5a7b1acb7f8b9a0a668bc961/html5/thumbnails/7.jpg)
� Established Quality Management System (DIN EN ISO 9001) since 1998
� Established Environmental Management System
COMPANY PROFILEMTU OG wins Ökoprofit Award (*)
(i.e: establishing local companies for ecological profit)
Page 7 / 3/16/2009
Management System (DIN EN ISO 14001) since 2008
� Continuous improvement of the system with several re-audits
� Participation in the project “Ökoprofit Augsburg“
![Page 8: Gas Power Systems Energy Efficient CHP Solutions for ... · PDF fileGas Power Systems Energy Efficient CHP Solutions for Commercial and Large-scale Residential Buildings ... 100% of](https://reader031.fdocuments.net/reader031/viewer/2022030405/5a7b1acb7f8b9a0a668bc961/html5/thumbnails/8.jpg)
GAS-PRODUCTS
Page 8 / 3/16/2009
![Page 9: Gas Power Systems Energy Efficient CHP Solutions for ... · PDF fileGas Power Systems Energy Efficient CHP Solutions for Commercial and Large-scale Residential Buildings ... 100% of](https://reader031.fdocuments.net/reader031/viewer/2022030405/5a7b1acb7f8b9a0a668bc961/html5/thumbnails/9.jpg)
PRODUCT OVERVIEWGENSETS AND CHP-SYSTEMS
Page 9 / 3/16/2009
MTU OE Series 40050/60 Hz, all gases
6L: 119 - 201 kWel12V: 227 – 404 (425) kWel
MTU Series 400050/60* Hz, natural gas
L62 L638V: 772 kWel 849 kWel
12V: 1 166 kWel 1286 kWel16V: 1 562 kWel 1711 kWel20V: 1 948 kWel 2145 kWel
*Step up gear box
![Page 10: Gas Power Systems Energy Efficient CHP Solutions for ... · PDF fileGas Power Systems Energy Efficient CHP Solutions for Commercial and Large-scale Residential Buildings ... 100% of](https://reader031.fdocuments.net/reader031/viewer/2022030405/5a7b1acb7f8b9a0a668bc961/html5/thumbnails/10.jpg)
Series 400
GR192B5 ���� Gensetinclusive Jacket water heat recovery
Data for biogasPel = 192 kW
GR192B5
Page 10 / 3/16/2009
Pth = 118 kWPin = 499 kW
�38,5% electrical efficiency
![Page 11: Gas Power Systems Energy Efficient CHP Solutions for ... · PDF fileGas Power Systems Energy Efficient CHP Solutions for Commercial and Large-scale Residential Buildings ... 100% of](https://reader031.fdocuments.net/reader031/viewer/2022030405/5a7b1acb7f8b9a0a668bc961/html5/thumbnails/11.jpg)
Module GC119N5���� System inclusive complete heat recoveryCompact design
Natural gas
Series 400GC119N5
Page 11 / 3/16/2009
Natural gasPel = 119 kWPth = 198 kWPin = 345 kW
�91,9% overall efficiency
�Excellent solution for buildings
![Page 12: Gas Power Systems Energy Efficient CHP Solutions for ... · PDF fileGas Power Systems Energy Efficient CHP Solutions for Commercial and Large-scale Residential Buildings ... 100% of](https://reader031.fdocuments.net/reader031/viewer/2022030405/5a7b1acb7f8b9a0a668bc961/html5/thumbnails/12.jpg)
PRODUCT OVERVIEWTECHNICAL DATA MTU-OE GAS GENSETS -SERIES 400
Range electrical output 119 – 404 (� 425) kW
Fuel Natural gas, biogas, sewage gas, landfill gas
(others on request)
Speed / Frequency 1500 / 50 Hz, 1800 / 60 Hz
Temperatures heating water circuit 194°F / 158°F, 21 2°F / 176°F
Page 12 / 3/16/2009
(outlet / inlet) (90°C / 70°C, 100°C / 80°C)
Temperatures mixture cooling circuit 104°F, 122°F, 1 58°F, 176°F
(40°C, 50°C, 70°C, 80°C)
Mixture cooling 1-stage, 2-stage
NOx – Emissions 50ppm @ 13%O2 (others on request, after treatment)
Electric efficiency
Thermal efficiency
Overall efficiency
36,1% - 38,8%
55,7% - 51,8%
91,8% - 90,6%
![Page 13: Gas Power Systems Energy Efficient CHP Solutions for ... · PDF fileGas Power Systems Energy Efficient CHP Solutions for Commercial and Large-scale Residential Buildings ... 100% of](https://reader031.fdocuments.net/reader031/viewer/2022030405/5a7b1acb7f8b9a0a668bc961/html5/thumbnails/13.jpg)
Series 4000 L62GB1166N5
GB1166N5 ���� Gensetwithout Jacket water heat recovery
Data Pel = 1166 kW
Page 13 / 3/16/2009
Pel = 1166 kWPth = 1260 kWPin = 2824 kW
�41,3% electrical efficiency
![Page 14: Gas Power Systems Energy Efficient CHP Solutions for ... · PDF fileGas Power Systems Energy Efficient CHP Solutions for Commercial and Large-scale Residential Buildings ... 100% of](https://reader031.fdocuments.net/reader031/viewer/2022030405/5a7b1acb7f8b9a0a668bc961/html5/thumbnails/14.jpg)
Series 4000 L62
GR1562N5 ���� Genset with Jacket water heat recovery
Data Pel = 1562 kW
GR1562N5
Page 14 / 3/16/2009
Pel = 1562 kWPth = 1700 kWPin = 3745 kW
�41,7% electrical efficiency
�194°F/158°F heating water temperature with exhaust heat exchanger
![Page 15: Gas Power Systems Energy Efficient CHP Solutions for ... · PDF fileGas Power Systems Energy Efficient CHP Solutions for Commercial and Large-scale Residential Buildings ... 100% of](https://reader031.fdocuments.net/reader031/viewer/2022030405/5a7b1acb7f8b9a0a668bc961/html5/thumbnails/15.jpg)
COGENERATION
Page 15 / 3/16/2009
![Page 16: Gas Power Systems Energy Efficient CHP Solutions for ... · PDF fileGas Power Systems Energy Efficient CHP Solutions for Commercial and Large-scale Residential Buildings ... 100% of](https://reader031.fdocuments.net/reader031/viewer/2022030405/5a7b1acb7f8b9a0a668bc961/html5/thumbnails/16.jpg)
� Available natural gas reserves are bigger than oil reserves
� Natural gas is the cleanest fossil fuel available
� CHP-plants can also be operated with gas from renewable energy or from waste sources (e.g. biogas, sewage, CBM and landfill gas)
� Leads to a efficient and cost effective use of energy by using also the emitted heat from the engine coolant and exhaust gas.
COGENERATIONADVANTAGES & BENEFITS
Page 16 / 3/16/2009
emitted heat from the engine coolant and exhaust gas.
� Reduction of CO2 emissions
� CH4 emissions by coal mines, landfill sites and sewage plants are harmful to the environment and can be treated in a profitable way by gas engine power stations
� CHP-plants are decentralised power stations which produce electric energy and heat close to where it is used
� Continuous operation (> 8.000 h/a), standby-operation, peak-load� reliable solution
![Page 17: Gas Power Systems Energy Efficient CHP Solutions for ... · PDF fileGas Power Systems Energy Efficient CHP Solutions for Commercial and Large-scale Residential Buildings ... 100% of](https://reader031.fdocuments.net/reader031/viewer/2022030405/5a7b1acb7f8b9a0a668bc961/html5/thumbnails/17.jpg)
COGENERATIONCOMPARISON
32%
Losses from Transmission and Conversion100%
Prime Energy Usable Energy Efficiency Ratio
Main Power Plant
-68%
Page 17 / 3/16/2009
up to 96%
+
+
75%
District Cogeneration Plant
Local Cogeneration Plant
-25%
-4%
![Page 18: Gas Power Systems Energy Efficient CHP Solutions for ... · PDF fileGas Power Systems Energy Efficient CHP Solutions for Commercial and Large-scale Residential Buildings ... 100% of](https://reader031.fdocuments.net/reader031/viewer/2022030405/5a7b1acb7f8b9a0a668bc961/html5/thumbnails/18.jpg)
COGENERATIONENERGY BALANCE
Traditional Power Generation compared to Distributed CHP
167,1
Primaryenergy
114,5
Combined cyclepower plantcoal firedη
η
=38 %
43,5 el. energygridtransmission
= 90 %
electricalenergy
η P = 59,2 %71 losses
2,2 losses
41,3
Boiler usable52,6
Page 18 / 3/16/2009
η
ηη
BoilerFuel oil
= 90 %
47,3
5,3 losses
76,3losses
usablethermalenergy
electricalenergy
usablethermalenergy
Distr. Cogenerationgas engine
= 41,3 %= 47,3 %
100Primary energynatural gas
41,3
47,3
11,4losses
52,6
![Page 19: Gas Power Systems Energy Efficient CHP Solutions for ... · PDF fileGas Power Systems Energy Efficient CHP Solutions for Commercial and Large-scale Residential Buildings ... 100% of](https://reader031.fdocuments.net/reader031/viewer/2022030405/5a7b1acb7f8b9a0a668bc961/html5/thumbnails/19.jpg)
COGENERATIONDESIGN OF CHP PLANT / SINGLE UNIT
Page 19 / 3/16/2009
![Page 20: Gas Power Systems Energy Efficient CHP Solutions for ... · PDF fileGas Power Systems Energy Efficient CHP Solutions for Commercial and Large-scale Residential Buildings ... 100% of](https://reader031.fdocuments.net/reader031/viewer/2022030405/5a7b1acb7f8b9a0a668bc961/html5/thumbnails/20.jpg)
TRIGENERATION WITH ABSORPTION-CHILLERS
Page 20 / 3/16/2009
![Page 21: Gas Power Systems Energy Efficient CHP Solutions for ... · PDF fileGas Power Systems Energy Efficient CHP Solutions for Commercial and Large-scale Residential Buildings ... 100% of](https://reader031.fdocuments.net/reader031/viewer/2022030405/5a7b1acb7f8b9a0a668bc961/html5/thumbnails/21.jpg)
� No mechanical compressor reduced maintenance costs
� Low electrical demand economic use of waste heat
� Sliding output control optimal adaption to demand
TRIGENERATIONADVANTAGES & BENEFITS
Page 21 / 3/16/2009
� Sliding output control optimal adaption to demand
� Low noise emission reduce effort for noise reduction
� Good for our environment positive image for your company
� Efficient solution for air conditioning systems in buildings
![Page 22: Gas Power Systems Energy Efficient CHP Solutions for ... · PDF fileGas Power Systems Energy Efficient CHP Solutions for Commercial and Large-scale Residential Buildings ... 100% of](https://reader031.fdocuments.net/reader031/viewer/2022030405/5a7b1acb7f8b9a0a668bc961/html5/thumbnails/22.jpg)
TRIGENERATIONPRINCIPAL DIAGRAM OF TRIGENERATION
Page 22 / 3/16/2009
![Page 23: Gas Power Systems Energy Efficient CHP Solutions for ... · PDF fileGas Power Systems Energy Efficient CHP Solutions for Commercial and Large-scale Residential Buildings ... 100% of](https://reader031.fdocuments.net/reader031/viewer/2022030405/5a7b1acb7f8b9a0a668bc961/html5/thumbnails/23.jpg)
TRIGENERATIONENERGY PROFILE
1200
1400
1600
1800
cons
umpt
ion
(MW
h)
Energy profile heat/cold/electricity(average monthly energy)
Page 23 / 3/16/2009
Jan Feb Mrz Apr Mai Jun Jul Aug Sep Okt Nov Dez
0
200
400
600
800
1000
1200
cons
umpt
ion
(MW
h)
Cold
HeatElectricity
![Page 24: Gas Power Systems Energy Efficient CHP Solutions for ... · PDF fileGas Power Systems Energy Efficient CHP Solutions for Commercial and Large-scale Residential Buildings ... 100% of](https://reader031.fdocuments.net/reader031/viewer/2022030405/5a7b1acb7f8b9a0a668bc961/html5/thumbnails/24.jpg)
APPLICATION EXAMPLES
Page 24 / 3/16/2009
![Page 25: Gas Power Systems Energy Efficient CHP Solutions for ... · PDF fileGas Power Systems Energy Efficient CHP Solutions for Commercial and Large-scale Residential Buildings ... 100% of](https://reader031.fdocuments.net/reader031/viewer/2022030405/5a7b1acb7f8b9a0a668bc961/html5/thumbnails/25.jpg)
APPLICATION EXAMPLEMTU FRIEDRICHSHAFEN – BOILER HOUSE
Page 25 / 3/16/2009
Module ME 16V4000 L61
Electrical output: 1,85 MWThermical output: 2 MWAnnual operating h: 7500 hCO2 saving: 1.700 t/a
![Page 26: Gas Power Systems Energy Efficient CHP Solutions for ... · PDF fileGas Power Systems Energy Efficient CHP Solutions for Commercial and Large-scale Residential Buildings ... 100% of](https://reader031.fdocuments.net/reader031/viewer/2022030405/5a7b1acb7f8b9a0a668bc961/html5/thumbnails/26.jpg)
Hospital Application in Bangladesh
� Electrical output: 2330 kW
APPLICATION EXAMPLE HOSPITAL APPLICATION
Page 26 / 3/16/2009
� Electrical output: 2330 kW� Heat rate: 1260 kW
2 x AE 12V 4000 supply the United Hospital with heat and power
![Page 27: Gas Power Systems Energy Efficient CHP Solutions for ... · PDF fileGas Power Systems Energy Efficient CHP Solutions for Commercial and Large-scale Residential Buildings ... 100% of](https://reader031.fdocuments.net/reader031/viewer/2022030405/5a7b1acb7f8b9a0a668bc961/html5/thumbnails/27.jpg)
APPLICATION EXAMPLE HOTEL APPLICATION
Trigeneration Plant – Hotel in Bayreuth2 x ME3042L3 (700 kWel, 840 kWth, 88,9% overall efficiency
Page 27 / 3/16/2009
![Page 28: Gas Power Systems Energy Efficient CHP Solutions for ... · PDF fileGas Power Systems Energy Efficient CHP Solutions for Commercial and Large-scale Residential Buildings ... 100% of](https://reader031.fdocuments.net/reader031/viewer/2022030405/5a7b1acb7f8b9a0a668bc961/html5/thumbnails/28.jpg)
APPLICATION EXAMPLE CONDOMINIUM – RESIDENTIAL AREA
Yatap – Seoul South Korea
3 x GC357N660Hz/380V-CHP-Plant3 x 357 kWel3 x 527 kWth
Page 28 / 3/16/2009
3 x 527 kWth
8.300 h/a (24/7) Start: 2004
![Page 29: Gas Power Systems Energy Efficient CHP Solutions for ... · PDF fileGas Power Systems Energy Efficient CHP Solutions for Commercial and Large-scale Residential Buildings ... 100% of](https://reader031.fdocuments.net/reader031/viewer/2022030405/5a7b1acb7f8b9a0a668bc961/html5/thumbnails/29.jpg)
THANK YOU FOR YOUR ATTENTION!
Page 29 / 3/16/2009