GAS / FLAME DETECTION GAS / DUST MONITORING
YOUR ENVIRONMENT,YOUR SAFETY, LET ’S MASTER THEM TOGETHER
MX 15= single channel
MX32 = 2 independant channels
WINGAS = 4 independant
channels
MX42A = 4 independant
channels
MX48 = 4 or 8 independant
channels
MX52 = 2 to 16 independant
mixted channels
MX62 = Up to 64 independant
channels
redundant system
Measurement and alarm unit:
MX 15
MX 15:easy installation
• small-sized wall-mounted box
• For low cost installations (boiler plants, battery charging rooms…)
• DIN rail mounting…
Measurement and alarm unit:
MX 15• Synergy with new detectors OLC(T)
10
• Can be linked either with a single flammable detector (OLC10/OLCT10)
• Or can be linked with two flammable detectors ( OLC10 TWIN)
• Or can be linked with one up to five toxic transmitters OLCT10
( CO, NO, NO2).
Example of wiring arrangement between MX15 and 3 -active- wire- detector: OLC10 or OLCT10.
between MX15
and two flammable detectors:OLC10
TWIN.
between MX15 and two toxic transmitters OLCT10.
MX 15 : user-friendly front panel
- LED visual indications:- ON/OFF- AL1 and AL2- Trouble
LCD display, pictograms, concentration, type of gas and unit indication(programmable).
MX 15 :alarms and relays
• ALARMS :• 2 independent
programmable levels• Increasing or
decreasing alarm• Automatic or
manual, local or remote acknowledgement.
• RELAYS:• 2 independent alarm
relays• 1 fault relay • Fail safe (energized)
or negative safety• Free potentiel
contacts (2A/250ACV).
MX15 : simple operation
• Keypad for using (menus):• initialization (1rst installation)
• programming (of channel)
• test (relays inhibited during calibration)
• code (authorized people)
• buzzer (mode).
MX 32:easy installation
• small-sized wall-mounted box
• protected front face
• IP66 housing .
MX 32: relays
• Per channel:
• 1 independent relay for each gas alarm (2)
• 1 common relay for troubles.
1
2
1
2D
MX 32:keypad
• maintenance menus:• initialization (1st installation)
• channel programming • calibration (relays inhibited)
• Code (authorized people) • buzzer ( local audible alarm).
MX 42A• Wall-mounting housing:
easy to install• 1 to 4 independent
channels
MX 42A : ergonomic front panel
MX 42A:relaysCOMMON BLOCK
Channel 1 channel2 channel 3 channel 4
1 21 21 21 2D 3
- per channel: 1 independent relay per instantaneous gas alarm (2) - 1 common relay for the 3rd gas alarms (from each channel),
or for all the gas alarms
- 1 common fault alarm relay
MX 42A:analog outputsCOMMON BLOCK
Channel 1 2 3 4
Common ground
- - - -++++
4 - 20 mA
an independent 4-20 mA output per channel.
- recorder or PLC ordata logging.
MX 42A: programming
MX 42A: maintenance
switches :678
Maintenance switches
• Position 0 = OFF• position 1 = ON
• 8 = on/off • 7 = calibration
(flashing yellow LED and alarm relay - inhibition)
• 7 + 6 = programming (flashing yellow LED and alarm relay - inhibition) .
6 7 8
0
1
Maintenance switches: calibration
• 8 + 7 = : calibration
• « 0 and Span » setting with potentiometers
7 8
KEYBOARD
• 8 : normal mode
• 7 + 6 = programming
Call on display(for 1 mn)
+-
Messages :- AL1- AL2- AL3- Point- Time
- states- values ...
WINGAS MULTI-CHANNEL CONTROLLER
WINGAS
• WINGAS is a fixed controller :
• with a wall mounting housing IP 54
• for COMMERCIAL and INDUSTRIAL markets.
WINGAS : 2 versions
• WINGAS DIGITAL: with display
• WINGAS : without display
WINGAS :multi-channel controller
• 4 channels
• 1 transmitter 4/20 mA 2 or 3 wires per channel
• specific case : up to a maximum of 5 transmitters CO 4/20 mA 2 wires
• No explo bridge detector.
WINGAS : configuration
Vers boîte relais
6 fils
123456
CASING
MAINPcb
FRONTPANEL
Display Pcb
WINGAS : ALARMS
• 2 GAS alarms per channel
COMMON FAULT ALARM
WINGAS : on-board RELAYS
• 2 GAS alarm common relays • 1 buzzer copy common relay• 1 FAULT alarm common relay
WINGAS: FRONT PANEL
Gas alarm lamps
On/off lamp
Fault lamp
Acknowledgementbutton
Maintenance button Display(digital version )
WINGAS DIGITAL
• Only in the case of a WINGAS DIGITAL we can connect a remote box fitted with 8 relays
• Each gas alarm AL1 and AL2 of WINGAS DIGITAL will then drive 2 remote relays AL1 and AL2.
REMOTE BOX
• The remote box is connected to the wingas digital with a 6 wire cable : max. length = 30m (0.9mm2).
to wingas digital
WINGAS NETWORK
Network: up to 32 WINGAS maximum
WINGAS NETWORK
• The network WINGAS RS 485 is driven by a software: WINGASCOM
• It allows to visualize and program the different WINGAS connected to the network
MX 48
• Metal wall- mounting housing
• 4 to 8 independent channels.
MX 48 : presentation
• BUS/MICRO/display card
• common block
• 2 cards (4 channels per card)
MX 48: front panel
• AL 1 and AL2 = instantaneous alarms
• AL 3 = delayed or averaged alarm
MX 48 :relays
- 2 relays (Al1/Al2) per channel
- 2 common relays(Al3 and faults)
channels 1 to 4 5 to 8
Analog outputs: 4 to 20 mA
-an independent 4 /20 mA output per channel :to recorder, PLC ....
communications: RS 232 and RS 485
COM 52
RS 232<
>
>
RS 485 SUPERVISION
COMMUNICATION
<
< < <
< <
<< >
>
>>
>
MX 48 : maintenance
• with push-buttons :
• calibration
• programming
MX 52
- rack 3U/19 inc.
- 2 to 16 channels ( features of MX 48 = MX 52 ).
MX 52 : configuration
MX 62
• a safety system ...