gas-catalog-2011.pdf
-
Upload
javierfox98 -
Category
Documents
-
view
691 -
download
6
description
Transcript of gas-catalog-2011.pdf
![Page 1: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/1.jpg)
![Page 2: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/2.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
73 Convenient LocationsMAINEAugusta 04330138 Leighton Road P.O. Box 5008 207.623.2521 800.322.4700 Fax: 207.622.2533
Bangor 0440167 Target Industrial Circle 207.947.6905 800.432.7371 ME only Fax: 207.947.8211
Biddeford 0400522 Landry Street 207.282.7558 800.443.0505 Fax: 207.282.0299
Caribou 04736420 Main Street 207.498.2526 800.339.3029 Fax: 207.498.2137
Ellsworth 046059 Buttermilk Road 207.667.9322 888.882.9322 Fax: 207.664.0201
Lewiston 042409 Forrestall Street P.O. Box 2546 207.784.4575 800.252.2000 Fax: 207.784.4205
S. Portland 04106 150 Postal Service Way 207.772.8364 800.482.0791 ME only Fax: 207.773.4571
Rockland 0484122 Merrill Drive 207.594.6200 800.287.0015 Fax: 207.594.9185
West Bath 04530P.O. Box 612 Bull Rock Bridge Road 207.442.7990 800.427.7990 Fax: 207.442.8377
Winslow 04901Mail to: P.O. Box 1569Waterville, ME 04903 Ship to: 37 Heywood Rd.Winslow, ME 04901 800.533.1172
F. W. Webb207.872.5522 800.640.9322 Fax: 207.872.8207
Kennebec Supply207.873.2111 Fax: 207.873.0152
Kentrol / Sevco207.873.7741 800.452.1928 Fax: 207.873.2945
Webb Pump207.873.7741 800.452.1928 Fax: 207.873.2945
MASSACHUSETTSAuburn 0150143 Sword Street Auburn Industrial Park 508.757.9322 800.872.0211 Fax: 508.757.8981
Bedford 01730160 Middlesex Turnpike 781.273.9322 800.221.9322 Fax: 781.270.0208
Bellingham 0201937 South Maple Street 508.966.4999 Fax: 508.966.1999
Boston 02118237 Albany Street 617.482.8387 Fax: 617.423.7858
Brockton 0230160 Industrial Boulevard 508.580.8310 800.544.9322 Fax: 508.584.6418
Canton 02021152 Will Drive 781.828.5559 Fax: 781.828.8060
Dedham 0202645 Commerce Way 781.329.6200 866.684.9322 Fax: 781.329.3531
Fitchburg 01420135 Falulah Street 978.345.4121 800.322.0899 Fax: 978.343.3749
Gloucester 0193051 Great Republic Dr. Blackburn Industrial Pk 978.283.7800 Fax: 978.281.7016
Greenfield 01301340 Chapman Street 413.773.3644 800.564.3644 Fax: 413.773.8205
Haverhill 01835270 Neck Road Ward Hill Business Park West 978.374.8448 800.521.7499 Fax: 978.373.7723
Hingham 0204345 Pond Park Road 781.749.9322 Fax: 781.740.4652
Hyannis 02601108 Breeds Hill Road 508.775.3890 800.352.3159 MA only Fax: 508.778.0409
Lowell 01851180 Olde Canal Drive 978.937.9322 800.642.9322 Fax: 978.937.5522
Malden 02148580.584 Broadway 781.322.7111 800.963.7111 Fax: 781.324.7773
Methuen 0184498 Lindbergh Avenue 781.325.7041 866.548.9322 Fax: 781.325.7051
Utilities Supply Co. (USCO)781.395.9023 800.343.7555 Fax: 781.395.2329
New Bedford 02745915 Church Street 508.995.9533 888.354.0048 Fax: 508.985.0934
Northampton 01060135 Industrial Drive 413.586.8100 800.282.7721 MA only Fax: 413.586.6280
Pittsfield 0120135 Commercial Street 413.448.8205 800.578.9322 Fax: 413.442.2251
Plymouth 023603 Collins Avenue 508.830.4666 Fax: 508.830.0481
Salem 01970295 Bridge Street 978.744.6550 800.345.5025 Fax: 978.744.1444
Springfield 01104153 Plainfield Street 413.781.1700 800.660.3141 Fax: 413.781.1705
Sturbridge 01566Pipe Depot9 Picker Road 508.347.3342 Fax: 508.347.4967
Woburn 0180150 Everberg Road 781.933.1804 800.253.7838 Fax: 781.933.3528
HVAC Controls781.933.1804 800.341.0110 Fax: 781.933.3528
NEW HAMPSHIREConcord 0330146 Henniker Street 603.223.6580 888.508.0050 Fax: 603.223.6585
Dover 0382010 Sumner Drive 603.749.3100 800.582.7196 Fax: 603.749.5572
Exeter 0383318 Continental Drive 603.772.3441 888.993.9322 Fax: 603.772.1866
Gilford 03249302 Hounsell Avenue 603.524.9322 800.345.1771 Fax: 603.527.1554
Keene 03431420 Winchester Street 603.357.1877 800 235.1218 NH only Fax: 603.357.7276
Lebanon 0376655 Etna Road 603.448.1980 800.322.8707 Fax: 603.448.6057
Madison 038491173 Conway Road 603.367.8852 800.852.9203 Fax: 603.367.4647
Manchester 0310325 Union Street 603.668.6488 800.789.6488 Fax: 603.668.7277
Nashua 030627 Redmond Street 603.883.3355 800.462.1440 NH only Fax: 603.595.7733
RHODE ISLAND Cranston 029203 Slater Road
Pipe, Valves, Fittings401.463.3741 800.795.6390 Fax: 401.463.4103
Webb PumpWebb Piping Products401.463.4108 866.850.7867 Fax: 401.463.6056
Webb Bio–Pharm401.463.4176 877.932.2246 Fax: 401.463.4160
Warwick 02888101 Jefferson Blvd. 401.463.8339 888.225.6850 Fax: 401.463.8661
CONNECTICUTFranklin 06254182 Route 32 860.642.9081 888.642.9086 Fax: 860.642.9082
Hartford 06114150 Locust Street 860.522.9322 800.252.9322 Fax: 860.246.3718
Hartford 06114Victor200 Locust Street 860.722.2433 800.243.9360 Fax: 800.274.2004
New Haven 06519650 Ella T. Grasso Blvd. 203.865.6124 866.416.9322 Fax: 203.624.5027
Waterbury 06708737 Bank Street 203.574.5959 800.572.6479 Fax: 203.753.2245
VERMONTBarre 0564110 Clark Road 802.479.3373 800.244.5044 VT only Fax: 802.479.2932
Bennington 05201240 East Road 802.447.2312 800.821.9506 Fax: 802.447.1481
Brattleboro 05301231 John Seitz Dr. Exit 1 Industrial Park 802.257.4316 800.821.9511 Fax: 802.257.7690
Rutland 057013091 Cold River Road 802.775.1922 800.622.4365 Fax: 802.773.7044
Springfield 051563 Charlestown Road 802.885.8127 800.872.5303 Fax: 802.885.2685
St. Albans 054785 Franklin Park West 802.527.0531 800.696.3763 Fax: 802.524.2093
St. Johnsbury 058192409 Portland Street 802.748.8101 800.872.8028 Fax: 802.748.3478
Williston 0549580 Park Avenue 802.879.5155 800.696.0340 Fax: 802.879.4848
NEW YORKAlbany 1220417 Erie Boulevard 518.472.9322 800.432.9322 Fax: 518.472.9399
Binghamton 1390462 Griswold Street 607.724.3170 888.593.9322 Fax: 607.724.4369
Cazenovia 13035 Kentrol/Sevco – Control Equipment Corp. (CEC) Mail to: PO Box 330Ship to: One Carriage Place Lane 315.655.9700 Fax: 315.655.9701
Canandaigua 14424 5297 Parkside Drive Suite 425 585.393.9322 800.828.8824 Fax: 585-393-6500
Newburgh 12550-6405600 Corporate Blvd. 845.567.0242 877.494.9322 Fax: 845.567.6019
Plattsburgh 129017327 Rte 9 518.562.2575 800.622.9322 Fax: 518.562.0117
Queensbury 128043 Highland Avenue 518.792.1316 800.826.0326 Fax: 518.792.1335
Syracuse 132116792 Townline Road 315.476.9322 800.262.9222 Fax: 315.472.4139
Utica 13501415 Broad Street 315.724.3191 Fax: 315.724.4067
![Page 3: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/3.jpg)
Victor is in no way responsible for errors, omissions or typos in the Heating Catalog. Further-more, the pictures, ads and editorials contained in the Heating Catalog are copyrighted and cannot be used in full or any part without express permission of the publisher.
Easy Ordering
ORDER ONLINE at: victormfg.com
Charge to your account, or we accept MasterCard, VISA and Business American Express.
To our Valued Customers,
We are pleased to bring you our 2011 Heating products catalog. If you’ve used our catalogs in the past, you’ll notice that something has changed with this edition. We’ve bundled our traditional heating cata-log and our Victor gas catalog providing you with an easy to use, single source for all your Oil, Natural and LP Gas product needs. Inside you’ll find hundreds of product pictures, descriptions, specifications, and Webb part numbers as well as a wealth of technical and cross reference info. The numbers, when used with our WebbConnect online ordering system, will give you inventory status, pricing and ordering capability, all with a click of the mouse.
With over 70 locations throughout New England and New York, you are never far from the products in this catalog. And, of course, we offer free delivery if that best suits your needs. All of our locations are listed to the left for easy reference. Please don’t hesitate to call the location most convenient to you for help at any time. Need to speak to an LP Specialist at Victor? Simply call 800-243-9360.
Sincerely,
Jeff Pope President F.W. Webb Company
![Page 4: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/4.jpg)
GAS EQUIPMENTVictor is the Northeast’s leading distributor of these premier gas equipment manufacturers.
![Page 5: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/5.jpg)
continued 4
Section Page
1 Regulators & Accessories 1 Regulators, Regulator Reliefs, Pigtails, POL Fittings
2 Valves & Accessories 30Cylinder and Service Valves, Multivalve Assemblies, Pressure Relief Valves & Relief Valve Manifolds, Globe & Angle Valves, Ball Valves, Excess Flow Valves, Filler Valves, Vapor Equalizing Valves, Internal Valves & Accessories, Adapters, Connectors & Fittings, Miscellaneous Equipment, Diagrams, Repair Kits
3 Meters/Meter Accessories 86 Meters, Meters Bars, Manifolds, Accessories
4 Cylinders, Tanks & Accessories 90ASME & Dot Cylinders, Motor Fuel Cylinders, Cylinder Cabinets, Cylinder Inverters, Scales, OPD Tools, Hand Trucks, ASME Tanks, ASME Replacement Parts, CAD Welding & Galvanic Protection
5 Paint & Supplies 102Tank Paint & Supplies, Decals & Signs
6 Gauges 107Cylinder Gauges, Tank Gauges, Pressure Gauges
7 Gas Pipe, Tubing & Fittings 118TracPipe, Counter Strike, Copper Tubing, Coated Copper Tubing, Underground PE Pipe, Bulk Hose, Sediment Traps, Lyco Fittings, Continental Fittings, Dormont Connectors, SAE Fittings, Barbed Hose Fittings, Black Iron Fittings, Forged Steel Fittings
GAS EQUIPMENT CATALOGTable of Contents
![Page 6: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/6.jpg)
8 Gas Heating 149Ignition Modules, Ignitors, Water Heater Controls, Gas Valves, Retrofit Kits, Water Safety Valves, Thermocouple & Thermopiles, Gas Orifices, Aluminum Tubing, Pilots, Hot Surface Igniters, Gas Valves Pressure Regulators
9 Pumps/Compressors 174Positive Displacement Meters, Hose Reels, Flex Connectors, Strainers, Swivel Connectors, Compressor Kits, Pump Station Kits, Propane Pumps, Selection Tables, Bypass Valves, Motors, Repair Parts
10 Miscellaneous Equipment 205Gas Conversion Burners, Vaporizers, Gas Lights, Gas Outlet Boxes
11 Tools & Chemicals 211Electrical Meters & Testers, Thermometers, Leak Detectors, Pressure Detectors, Carbon Monoxide Detectors, Underground Pipe Locators, Vacuum Cleaners, Gloves, Hand Tools, Power Tools, Flashlights, Lubricants, Chemicals, Test Kits
13 Appendices 213
Index i
Section Page
GAS EQUIPMENT CATALOGTable of Contents (continued)
![Page 7: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/7.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
reg
ula
to
rs
& a
cc
es
so
rie
s
1
1
1SECTION
RegulatorsCompact High Pressure First Stage RegulatorIdeal for use as a first stage regulator on any domestic size ASME or DOT container in propane gas installations requiring no more than 1,500,000 BTU’s/hr. These regulators are factory set to reduce tank pressure to an intermediate pressure of approximately 10 PSIG.
High Pressure First Stage RegulatorsLV4403 SeriesProvides accurate first stage regulation in two-stage bulk tank systems. These regulators handle vaporization of tanks up to 1200 gallons. Reduce tank pressure to an intermediate pressure of 5 to 10 PSIG. Also used to supply high pressure burners for applications like industrial furnaces or boilers. Also incorporated in multiple cylinder installations.
Second Stage Regulator for 2 PSIG SystemsLV4403Y & LV5503Y SeriesDesigned to reduce first stage pressure of 10 PSIG down to 2 PSIG. Systems that utilize this regulator use smaller than normal piping inside of the building. A special final stage regulator, not the appliance regulator, is required to reduce this intermediate 2 PSIG pressure down to 11” w.c.
LV3403TR* Maximum flow based on 15 PSIG inlet pressure and 8 PSIG delivery.
* when used for final stage pressure control, must either incorporate integral relief valve or separate relief valve should be specified in accordance with NFPA Pamphlet 58.** Maximum flow based on inlet pressure 20 PSIG higher than the regulator setting and delivery pressure 20% lower than the setting.
LV4403Y4
LV4403TR9
MFR#Inlet
connectIonoutlet
connectIonoRIFIce
sIze
FactoRy delIveRy pRessuRe
bonnet vent
posItIon
vapoR capacIty btu/hR.
pRopane* Webb#LV3403TR 1/4” F. NPT 1/2” F. NPT 1/4” 10 PSIG Over Outlet 1,500,000 162774
* Backmount Design** Maximum flow based on 10 PSIG inlet pressure and 2 PSIG delivery pressure.
MFR#Inlet
connectIonoutlet
connectIonoRIFIce
sIzeadJustMent
RanGe
bonnet vent
posItIon
vapoR capacIty btu/hR.
pRopane** Webb#
LV4403Y4 1/2” F. NPT 1/2” F. NPT 1/4” 2 PSIG at 10 PSIG Inlet Over Inlet 1,000,000 192612
LV4403Y46R* 1/2” F. NPT 3/4” F. NPT 1/4” 2 PSIG at 10 PSIG Inlet Over Inlet 1,000,000 250285
LV5503Y6 3/4” F. NPT 3/4” F. NPT 1/4” 2 PSIG at 10 PSIG Inlet Over Inlet 2,200,000 250286
LV5503Y8 3/4” F. NPT 1” F. NPT 9/32” 2 PSIG at 10 PSIG Inlet Over Inlet 2,200,000 250287
MFR#Inlet
connectIonoutlet
connectIonoRIFIce
sIze
FactoRy delIveRy pRessuRe
adJustMent RanGe* (psIG)
InteGRal RelIeF
Included
vapoR capacIty btu/hR.
pRopane** Webb#LV4403SR4
1/2” F. NPT1/2” F. NPT
1/4”
5 1-5
Yes 2,500,000
187108LV4403TR4 10 5-10 187110LV4403SR9
F. POL
5 1-5 162780LV4403TR9 10 5-10 162781LV4403SR96
3/4” F. NPT5 1-5 187109
LV4403TR96 10 5-10 162782
![Page 8: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/8.jpg)
2 victormfg.com
1SECTION
Gas Equipment Catalog
Regulators
Large Low Pressure Second Stage RegulatorsDesigned to reduce first stage pressure of 5 to 20 PSIG down to burner pressure. Ideal for larger commercial and industrial applications, multiple cylinder installations and large domestic systems.
Low Pressure Second Stage RegulatorsDesigned to reduce first stage pressure of 5 to 20 PSIG down to burner pressure, normally 11” w.c. Ideal for medium commercial installation, multiple cylinder installations and normal domestic loads.
MFR#Inlet
connectIonoutlet
connectIon oRIFIce sIze
FactoRy delIveRy pRessuRe
adJustMent RanGe
bonnetvent
posItIon
vapoR capacIty btu/hR. pRopane Webb#
LV5503B4 1/2” F. NPT3/4” F. NPT 1/4”
11” W.C. at10 PSIG Inlet
9” to 13” W.C. Over Inlet1,600,000 162783
LV5503B63/4” F. NPT 162784
LV5503B8 1” F. NPT 9/32” 2,300,000 187111LV6503B14 11/2” F. NPT 11/2” F. NPT
5/8” 81/2” to 14” W.C. —8,000,000 241847
LV6503B16 2” F. NPT 2” F. NPT 9,750,000 243018
MFR#Inlet
connectIonoutlet
connectIonoRIFIce
sIze
FactoRy delIveRy pRessuRe
adJustMent RanGe
bonnetvent
posItIon
vapoR capacIty btu/hR.
pRopane Webb#
LV5503G4 1/2” F. NPT 3/4” F. NPT 1/4” 15” W.C. at15 PSIG Inlet 8” to 18” W.C. Above Inlet 1,750,000 193313
MFR#Inlet
connectIonoutlet
connectIon oRIFIce sIze
FactoRy delIveRy pRessuRe
adJustMent RanGe
vent posItIon
vapoR capacIty btu/hR. pRopane Webb#
LV4403B41/2” F. NPT
1/2” F. NPT
#28 Drill 1” W.C. at 10 PSIG Inlet 9” to 13” W.C. Over Inlet
935,000
162775LV4403B46
3/4” F. NPT
162776LV4403B46R* 162777LV4403B66
3/4” F. NPT
162778LV4403B66R* 162779LV4403B66RA**
1,000,000 262352LV4403B66RAB*** 262353
*Backmount Design. **90º Body. ***90º Body with Brackett.
Low Pressure Second Stage Tobacco Barn RegulatorEspecially developed for drying barns in the tobacco industry. The LV5503G regulator will supply steady and constant flow of fuel to as many as 12 to 20 burners throughout the barn.
LV4403B66R
LV5503B4
LV5503G4
![Page 9: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/9.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
reg
ula
to
rs
& a
cc
es
so
rie
s
1
3
1SECTION
RegulatorsCompact Twin Stage RegulatorsThis compact two-stage regulator is designed to reduce container pressure down to 11” w.c. or 2 psi delivery pressure. It is ideal for “on-site” cylinder applications, mobile homes and average domestic service including small ASME and 100 to 420 pound DOT cylinders.
LV404B4
Compact Twin Stage RegulatorsThe compact twin-stage regulator is designed to reduce container pressure down to 11” w.c. delivery pressure. It is ideal for “on site” container applications such as homes, mobile homes and cottages for average domestic service; including small ASME tanks and 100-420 pound DOT cylinders.
LV404B34 LV404B39
MFR#Inlet
connectIonoutlet
connectIonoRIFIce
sIze
FactoRy delIveRy pRessuRe
adJustMent RanGe
2nd staGe
bonnetvent
posItIon 1st
staGe
bonnetvent
posItIon 2nd
staGe
capacIty btu/hR.
pRopane**
acces-soRIes
1st staGe vent
pIpe-aWay Webb#LV404B4
1/4” F. NPT1/2” F. NPT
.219
11” W.C. at 100 PSIG
Inlet9” to 13” W.C.
Down Over Outlet
525,000404PE
162787LV404B4V9 9 o’clock 9 o’clock 162788LV404B46 3/4” F. NPT Down Over Outlet 162789LV404B9
F. POL1/2” F. NPT
Down Over Outlet 187105LV404B9V9 9 o’clock 9 o’clock 214088LV404B96 3/4” F. NPT Down Over Outlet 187106LV404Y9 1/2” F. NPT 2 PSI 1.8 to 2.5 PSI Down Over Outlet 800,000 359411
MFR#Inlet
connectIonoutlet
connectIonoRIFIce
sIze
FactoRy delIveRy
pRessuRe
adJustMent RanGe
2nd staGe
bonnetvent
posItIon 1st
staGe
bonnetvent
posItIon 2nd
staGe
capacIty btu/hR.
pRopane**
accessoRIes
Webb#
1st staGe vent pIpe-aWay
2nd staGe vInyl
coveR bRacketLV404B34 1/4” F. NPT
1/2” F. NPT .10011” W.C. at 100 PSIG
Inlet9” to 13” W.C.
Rear Over Outlet450,000 404PE 2302-55 2302-31
162785LV404B39 F. POL 191088LV404B34V9 1/4” F. NPT
Left 9 o’clock 162786LV404B39V9 F. POL 202171
Twin Stage Automatic Changeover RegulatorsThese combination automatic changeover, two stage regulators are especially suitable for homes, mobile homes, cottages, construction and other portable two cylinder installations. Empty containers may be replaced without interrupting customer’s gas service.
7525B
MFR#
seRvIce & ReseRve IndIcatoR
Inlet connectIons
outlet connectIons
FactoRy delIveRy
pRessuRe*adJustMent
RanGe
bonnet vent
posItIonbRacket Included
capacIty btu/hR.
pRopane** Webb#7525B23
Integral 1/4” Inverted Flare 1/2” F. NPT 11” W.C. 9” to 13” W.C. Over Outlet2302-31 200,000 162790
7525B4 2503-22A 450,000 162792* Set at 100 PSIG inlet pressure.** Maximum flow based on 25 PSIG inlet pressure and 9” water column delivery pressure.
![Page 10: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/10.jpg)
4 victormfg.com
1SECTION
Gas Equipment Catalog
Regulators
302
302V
Compact RegulatorsThese compact regulators are designed for smaller outdoor grills and fish cookers. It is intended for use on small portable appliances that use 100,000 BTU’s/hr. or less. It may not be used on fixed pipe systems per NFPA 58, 1995 edition.
Automatic Changeover Regulator OutfitsThese outfits contain the equipment required to provide automatic changeover regulation.
7523B4
7523B23
MFR# typeInlet
connectIonoutlet
connectIonoRIFIce
sIze
FactoRy delIveRy pRessuRe
adJustMent RanGe
bonnet vent
posItIon
vapoR capacIty btu/hR.
pRopane Webb#
302
Single Stage
1/4” F. NPT
3/8” F. NPT No. 50 Drill
11” W.C. at 100 PSIG
Inlet9” to 13” W.C.
Small Vent Above Inlet
125,000
86837
302V9 Drip Lip at 9 o’clock
273820
302V9LS Soft POL Without Orifice 162715
302V9 Hard Nose
9 o’clock Vent
273820302VW Vent Port 275124
302VW POL Hand Wheel 186839
PIGMEGR-766 90º With QCC 1 362733PIGMEFMCULH 1/4” With QCC 1 Straight 362734
MFR#
autoMatIc chanGeoveR ReGulatoR Included Inlet outlet
pIGtaIls Included-2
pIGtaIl sIzes
bRacket Included
capacIty btu/hR.
pRopane Webb#5726B23 7525B23
1/4” Inverted
Flare1/2”
F. NPT
912FA20 11/8” POL2312-31 200,000 162794
5727B23 7525B23 912FS20 7/8” POL 1627955744B4 7526B4 912FA20 11/8” POL
2503-22 450,000 1868615745B4 7525B4 912FS20 7/8” POL 186862
![Page 11: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/11.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
reg
ula
to
rs
& a
cc
es
so
rie
s
1
5
1SECTION
RegulatorsHigh Pressure Pounds-to-Pounds RegulatorIndustrial/CommercialDesigned to reduce propane gas container pressure down to between 3 and 100 PSIG. Ideal for liquid or vapor service, they can be used in a variety of applications including salamander heaters, weed burning torches, fish cookers, tar pot heaters, and other industrial type services.
597FA-D
MFR#adJustMent
MethodInlet
connectIonoutlet
connectIon
RecoMMended delIveRy
pRessuRe RanGe (psIG)
capacIty deteRMIne at set pRessuRe
oF psIG
capacIty btu/hR.
pRopane Webb#597FA
Tee Handle 1/4” F. NPT 1/4” F. NPT
1-15 10 1,750,000 162716597FB 10-30 20 3,000,000 162717597FC 20-45 30 3,500,000 162718597FD 40-100 60 4,500,000 162719
MFR# seRvIceadJustMent
Method
Inlet & outlet
connectIon
RecoMMended delIveRy pRessuRe
RanGe (psIG) WIdthheIGht (Max.)
capacIty deteRMIne at set pRessuRe
oF psIG capacIty Webb#AA1582MW
NH3
Tee Handle
1/4” F. NPT3-25
23/16” 4”20 2,100 CFH NH3 187087
AA1582ML 20-50 30 2,400 CFH NH3 187086AA1582MH 45-125 60 2,600 CFH NH3 187085
1584MN
LP-Gas
1/2” F. NPT
3-30
215/16” 47/8”
20 7,000,000 BTU/hr. LPG 162800
1584ML 25-50 30 7,500,000 BTU/hr. LPG 162799
1584MH 45-125 60 8,000,000 BTU/hr. LPG 186810
AA1584MWNH3
3-25 20 4,500 CFH NH3 187089AA1584ML 20-25 30 4,800 CFH NH3 162412AA1574MH 45-125 60 5,100 CFH NH3 189234
1586MN
LP-Gas
3/4” F. NPT
3-30
31/2” 7”
20 11,000,000 BTU/hr. LPG 162802
1586ML 25-50 30 12,000,000 BTU/hr. LPG 162801
1586MH 45-125 60 14,000,000 BTU/hr. LPG 189126
AA1586MWNH3
3-25 20 7,000 CFH NH3 162414AA1586ML 20-50 30 7,700 CFH NH3 162413AA1586MH 45-125 60 8,900 CFH NH3 189235
1588MN
LP-Gas 1” F. NPT
3-30 20 11,000,000 BTU/hr. LPG 162804
1588ML 25-50 30 12,000,000 BTU/hr. LPG 250280
1588MH 45-125 60 14,000,000 BTU/hr. LPG 162803
High Pressure Pounds-to-Pounds RegulatorsCommercial/IndustrialDesigned to reduce LP gas and anhydrous ammonia container pressures to between 3 and 125 PSIG. Precision-built with a multi-million BTU capacity, the 1580M Series is perfect for such big, tough jobs as crop dryers, asphalt batch mixing plants, road building “tar wagons”, heat treating and other large industrial and commercial loads.
1584MW
![Page 12: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/12.jpg)
6 victormfg.com
1SECTION
Gas Equipment Catalog
Regulator accessoriesHigh Pressure/High Temperature Pounds-to-Pounds Industrial/CommercialDesigned to reduce LP-Gas container pressures to between 3 and 50 PSIG. Ideal for crop drying, heat treating, asphalt batch mixing and other large industrial and commercial load application utilizing high temperature LP-Gas or high temperature atmosphere under conditions up to 300°F.
High Pressure Pounds-to-Pounds Regulator AccessoriesIndustrial/CommercialDesigned for use as a relief valve on first stage regulators that comply with NFPA 58 2.57.5 exception: “first stage regulators with a rated capacity of more that 500,000 BTU/hr. shall be permitted to have a seperate relief valve.
X1584MW
3139
MFR# seRvIcesadJustMent
MethodInlet & outlet
connectIonRecoMMended delIveRy pRessuRe RanGe (psIG)
capacIty deteRMIned at set pRessuRe oF psIG
capacIty btu/hR.
pRopane Webb#X1584MN
LP Gas Tee Handle1/2” F. NPT
3-20 20 7,000,000 190688X1584ML 25-50 30 7,500,000 190687X1586MN
3/4” F. NPT3-30 20 11,000,000 250279
X1586ML 25-50 30 12,000,000 250290
MFR#set
pRessuReReGulatoR
settInGsconnectIon
sIze heIGht WIdth
FloW capacIty at 120% oF set pRessuRe
(scFh pRopane) Webb#3139-18 18 PSIG 10 PSIG
1/4” M. NPT 227/32” 11/16”1357* 266443
3139-26 26 PSIG 16 PSIG 1725** 2664373139-38 38-PSIG 20 PSIG 2304*** 315791
* Flow recorded at 21.6 PSI inlet pressure for this valve.** Flow recorded at 31.2 PSI inlet pressure for this valve.*** Flow recorded at 45.6 PSI inlet pressure for this valve.
Victor/F.w. Webb offers webbConnect! you can order, check current pricing
and inventory 24/7!
![Page 13: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/13.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
reg
ula
to
rs
& a
cc
es
so
rie
s
1
7
1SECTION
Regulator accessoriesCopper PigtailsPigtails are available in a variety of connections, sizes and styles. care should always be taken in selecting the proper pigtail for a particular application.Note: Engineered controls International, Inc., recommends a new pigtail be installed with every new and replaced regulator.912JS20
MFR# connectIonsappRox. lenGth tube
7/8” hex shoRt nIpple
11/8” hex lonG nIpple Webb#
alt MaRshall pIG# Webb#
912PS12
M. POL X M. POL
12”
1/4”
7/8” —
188575 — —912PS20 20” 162812 — —912PS30 30” — PIG1664-30 186531912PS36 36” 162813 — —912PS48 48” 162814 — —912FS12
1/4” Inverted Flare X M. POL
12” 216766 PIG1665-12 186532912FS20 20” 162806 — —912FS30 30” 275012 — —912FS36 36” 162807 — —
— POL X 1/4” Inverted Flare 48” — PIG1665-48 186535
912JS121/4”
M. NPT X M. POL
12” 162808 PIG1663-48 186530912JS20 20” 162809 — —912JS36 36” 188577 — —— POL X 1/4” 48” — — PIG1669-48 186539912PA20
M. POL X M. POL20”
— 11/8”
162810 — —912PA36 36” 275011 PIG1660-36 186525912PA48 48” 162811 — —
912FA20 1/4” Inverted Flare X M. POL 20” 162805 — —
913PS05
M. POL X M. POL
5”
3/8” 7/8” —
273819 — —913PS12 12” 202603 — —913PS20 20” 188582 — —913PS30 30” 250283 PIG1680-30 186544913PS36 36” 250284 — —913PS48 48” 188581 — —913JS05A
90º Pre Bent5” 186999 — —
913JS12 12” 250282 — —— POL X 1/2 MPT 20” — PIG1684-20 186547
913S20 1/4” M. NPT X M. POL 20” 187000 PIG1679HP-20 186549
![Page 14: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/14.jpg)
8 victormfg.com
1SECTION
Gas Equipment Catalog
Regulator accessories
Patented Presto-taP Pigtail Part numbers1/4” tube
Fugitive emission reduction
Webb #connections aPProx.
length7/8” hex
short niPPlePigtail length 1/4” tube 3/8” tube
M.POL x M.POL 12” PT912PS12 12” 80% 91% 24416720” PT912PS20 20” 82% NA 43301948” PT912PS48 48” 88% NA 433020
1/4” Inverted Flare x M.POL 20” PT912FS201/4” M. NPT x M.POL 12” PT912JS12
20” PT912JS20
3/8” tube
connections aPProx. length
7/8” hex short niPPle
M.POL x M.POL 12” PT913PS121/4” M. NPT x M.POL 12” PT913JS12
Patented tank Pressure FittingWebb #
Part # thread core body Wrench Flat
caP Wrench Flat hex #54 oriFice aPPlication
LDS2000RV 1/8 NPT Viton 7/16 9/16 Yes Tank Pressure 244172
regulator & aPPliance FittingWebb #
Part # thread core body Wrench Flat
caP Wrench Flat hex #54 oriFice aPPlication
RVL 1/8 NPT Viton 7/16 9/16 No Low Pressure 433023
Patented Pigtail Products Applicatoin: Pigtails are available in a variety of sizes and styles. care should always be taken in selecting the proper pigtail for a particular application.
Patented Tank Pressure Fittings Application: The patented Presto-Tap LDS2000RV is designed to obtain pressure readings and perform system leak testing using tank pressure without ever breaking the system. Meets NFPA 54 & 58 requirements regarding excess flow. compatible with all Presto-Tap® gauge products when used at correct locations
Regulator & Appliance FittingApplication: The RVL low pressure fitting is designed to obtain pressure readings at first and second sage regulators. compatible with all Presto-Tap® gauge products when used at correct locations.
Pigtails
![Page 15: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/15.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
reg
ula
to
rs
& a
cc
es
so
rie
s
1
9
1SECTION
Regulator accessories
tank Pressure FittingWebb #
Part # thread core body Wrench FlatTPF 1/4” F. NPT 1/4” F. NPT Up to 90% 260646
Presto-Tap® High Pressure Gauge Products & Accessories Application: 300# Gauge is used to obtain pressure readings and perform leak tests at tank pressure locations prior to 1st stage regulators such as Presto-Tap® pigtails and RegO “Ready To Go Valves”.
Part numbers
gauge bleeder(244170)
90° quick adaPter(244173)
straight quick
adaPter(433013)
glycerin Filled gauge(433005)
dry gauge(433004)
belt looP
holster(433012)
belt looP holster(379916)
Webb #
6800-90 X X X 244174
6800-B90 X X X X 433007
6800-BH90 X X X X 433018
6800D-90 X X X 433010
6800D-B90 X X X X 433010
6800D-BH90 X X X X 433011
Presto-Tap® Patented Tank Pressure Fitting Application: Low cost, permanently installed fitting between tank service valve and first stage regulator providing leak test capability without the use of tools. Eliminates the need to discard pigtail to access tank pressure.
Presto-Tap® Low Pressure Gauge Products & Accessories Application: 30# Gauge is used to perform leak tests downstream of 1st stage regulators by connecting quick adapters to Presto-Tap® LDS2000RV installed in 1st & 2nd stage regulator taps accessing 1st stage pressure.
First stage regulator leak testing 0-30# gauge Products
Part numbers
gauge bleeder(244170)
90° quick adaPter(244173)
straight quick
adaPter(433013)
glycerin Filled gauge(433005)
dry gauge(433004)
belt looP
holster(433012)
belt looP holster(379916)
Webb #
First stage regulator leak testing 0-30# gauge ProductsPT30-LP X X X X 433015
loW Pressure leak leak testing 0-35# Wc gauge ProductsPT-OZ X X N/A X X 433016
![Page 16: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/16.jpg)
10 victormfg.com
1SECTION
Gas Equipment Catalog
Regulator accessories
BracketsRegO® Brackets are especially designed for use in installing RegO® Regulators in applications requiring the use of a bracket.
2503-19 2503-22 2302-31
Tee Check ManifoldsFor use in systems that require uninterrupted gas service during cylinder exchange. Especially for summer cottages, mobile homes and single appliance loads.
Multiple Cylinder ManifoldsUse with suitable pigtails to connect multiple cylinders together. Ideal for loads that require more than one cylinder to be in service at a time.
1350R
1450R
1350E
1450E
POL Inlet FittingsThese inlet fittings are available for assembly into either first stage or single stage regulators. All except for 970JR (1/4” hose barb) are machined from brass.
970 970AX 970AXS
970AW 970HT 970S
MFR# descRIptIon Webb#970 Hard nose POL with wrench nut. 191818970AX Hard nose POL with wrench nut and excess flow. 187003970AXS Soft nose POL with wrench nut and excess flow. 2465653199W Heavy duty hard nose POL with wrench nut and excess flow. 186856970AW Soft nose POL with handwheel. 187002970HT Soft nose POL with handwheel and 60 DMS orifice. 243117970S Soft nose POL with wrench nut and 60 DMS orifice. 162771970JR Hard nose POL X 1/4” hose barb. 190842
MFR# MateRIalFoR use WIth
ReGulatoR Model Webb#2302-31 Cadium Plated
Steel2302 Series/404B23 162798
2503-22 LV404 Series, 2503 Series, LV4403 Series
1627972503-19 Aluminum 162796
MFR#Inlet
connectIonsoutlet
connectIon Webb#1350R F. POL M. POL 1628201450R 1/4” Inverted Flare 1/4” M. NPT 162821
MFR#Inlet
connectIonsoutlet
connectIon Webb#1350E F. POL M. POL 1628191450E 1/4” Inverted Flare 1/4” M. NPT 162822— 11/8” HEX L/Check —
MaRshall pIG# Webb#
PIG1000A 186519PIG1702A 186552
MaRshall pIG# Webb#
PIG1701B 186551PIG1702B 186553
![Page 17: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/17.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
reg
ula
to
rs
& a
cc
es
so
rie
s
1
Regulators
11
SECTION
1Model 046 First Stage Field Regulators
MFR# descRIptIonpIpe
sIzes body Webb#EQU046-12
High Pressure RegulatorFirst stage with internal relief valve.
3/4”Str
181910EQU06-16 1” 181929EQU06-20 11/4” 181930
natuRal Gas (sp 0.6) capacIty (scFh) oRIFIce
outlet pRessuRe psI body sIze
oRIFIce sIze1/8” 3/16” 1/4” 5/16” 3/8” 1/2”
53/4” 1190 2213 2775 3150 3375 40131” 1190 2213 3975 6150 6375 7123
11/4” 1190 2213 3975 6375 8100 7030
103/4” 1190 2213 3638 4258 4453 64351” 1190 2213 3900 5395 5775 5920
11/4” 1190 2213 3900 5395 5940 6660
1350 btu pRopane/aIR MIx (sp 1.20) capacIty (scFh) oRIFIce
outlet pRessuRe psI body sIze
oRIFIce sIze1/8” 3/16” 1/4” 5/16” 3/8” 1/2”
53/4” 845 1571 1970 2237 2396 28491” 845 1571 2822 4367 4526 5057
11/4” 845 1571 2822 4526 5751 4991
103/4” 845 1571 2583 3023 3162 45691” 845 1571 2769 3830 4100 4203
11/4” 845 1571 2769 3830 4217 4720
pRopane (sp 1.53) capacIty (btu/hR)*
outlet pRessuRe psI
body sIze
oRIFIce sIze1/8” 3/16” 1/4” 5/16” 3/8” 1/2”
53/4” 1,866,000 3,468,272 4,349,024 4,938,680 5,289,488 6,289,6641” 1,866,000 3,468,272 6,229,952 9,641,000 9,991,808 11,163,656
11/4” 1,866,000 3,468,272 6,229,952 9,991,808 12,696,264 11,019,352
103/4” 1,866,000 3,468,272 5,702,496 6,675,304 6,978,840 10,086,3521” 1,866,000 3,468,272 6,113,016 8,456,712 9,051,344 9,280,240
11/4” 1,866,000 3,468,272 6,113,016 8,456,712 9,310,096 10,439,648
Yellow Spring (04600-021-00) Outlet Pressure 3-10 psi at 75 psi Inlet Pressure
* Note 1: Propane chart is a mathematical extrapolation using 0.63 correction factor and 2,488 btu/hr = 1 cubic foot from NFPA-58, 2008.
![Page 18: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/18.jpg)
12 victormfg.com
Regulators 1SECTION
Gas Equipment Catalog
Model 143-80 Second Stage Service RegulatorsThe 143-80 is designed and built for domestic gas service, as well as for commercial and industrial applications; burners, furnaces, ovens, heaters, gas engines, etc. it can also be used for air, LPG, nitrogen, dry cO2 and other gases.Simple, rugged construction means dependability. Yet, it provides precise pressure control over an amazing range of pressure and load conditions.It is simple to install and adjust. The union nut connection makes it easy to locate the regulator in the best installed position, and servicing is easy and convenient.
MFR# descRIptIon sIze Webb#143-80-212
Regulator With Internal Relief Valve (IRV)3/4” Body 181913
143-80-216 1” Body 181909143-80-220 11/4” Body 188875143-80-2HP Special High Pressure Outlet Up To 6 psi 1” Body 247441
Maximum Inlet PressuresSpring Ranges
outlet pRes-suRe RanGes spRInG coloR
spRInG paRt nuMbeR Webb#
31/2” to 61/2” W.C. Red 143-62-021-15 1819525” to 81/2” W.C. Blue 143-62-021-16 1888726” to 14” W.C. Green 143-62-021-17 274440
12” W.C. to 1 psi Orange 143-62-021-18 1866731/2” psi to 2 psi Black & White 143-92-021-22 1888762 psi to 6 psi Black* 139-16-021-01 —
Capacities for Other GasesFor capacities (in ScFH) of other gases, multiply the capacity values by a correction factor from the table below:
otheR Gases specIFIc GRavIty coRRectIon FactoRPropane 1.53 0.63
oRIFIce sIzes 5/8” 1/2” 3/8” 5/16” 1/4” 3/16” 1/8”
Max Inlet Pressure 10 psi 20 psi 40 psi 40 psi 60 psi 125 psi 125 psi
* Good for use in 143 802HP Series only
pIpe sIze
Inlet pRessuRe
psI
oRIFIce sIze
1/8” 3/16” 1/4” 5/16” 3/8” 1/2” 5/8”
3/4” X 3/4”
0.5 340 450 5101 480 500 510 5302 530 560 570 580 6003 420 600 620 630 650 6705 250 560 700 720 730 770 790
71/2 310 700 840 860 880 900 90010 370 830 950 970 1000 1020 102020 530 1200 1220 1240 1250 127040 860 1570 1330 1340 145060 1200 1660 152080 1500 1710
125 1800 1900
pIpe sIze
Inlet pRessuRe
psI
oRIFIce sIze
1/8” 3/16” 1/4” 5/16” 3/8” 1/2” 5/8”
1” X 1”
0.5 350 460 5201 480 550 600 6502 530 700 840 880 7803 420 650 870 1000 920 8105 250 580 890 1120 1160 950 970
71/2 310 700 1140 1340 1270 1140 106010 370 840 1360 1500 1330 1200 118020 530 1230 2000 1600 1480 140040 860 1700 2000 1640 190060 1200 1900 200080 1540 2000
125 2100 2100
pIpe sIze
Inlet pRessuRe
psI
oRIFIce sIze
1/8” 3/16” 1/4” 5/16” 3/8” 1/2” 5/8”
11/4” X 11/4”
0.5 350 460 5201 480 550 680 7602 530 700 840 1020 10303 420 650 870 1030 1200 10505 250 580 890 1180 1350 1490 1060
71/2 310 700 1140 1500 1610 1580 106010 370 840 1360 1700 1710 1800 118020 630 1230 1600 1800 1900 190040 860 1800 2200 1900 200060 1200 2100 240080 1550 2200
125 2250 2400
Natural Gas Chart143-80-2, and 143-80-2hp —capacity in scFh natural Gas (0.6 Specific Gravity, 14.65 psia, 60ºF)
![Page 19: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/19.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
reg
ula
to
rs
& a
cc
es
so
rie
s
1
Regulators
13
SECTION
1
pIpe sIze
Inlet pRessuRe
psI
oRIFIce sIze
1/8” 3/16” 1/4” 5/16” 3/8” 1/2” 5/8”
1” X 1”
0.5 549 721 8151 752 862 940 10192 831 1097 1317 1379 12233 658 1019 1364 1567 1442 12705 392 909 1395 1756 1818 1489 1661
71/2 486 1097 1787 2100 1991 1787 185010 580 1317 2132 2351 2085 188120 831 1928 3135 2508 2320 219440 1348 2665 3135 2571 297860 188 2978 313580 2414 3135
125 3292 3292
pIpe sIze
Inlet pRessuRe
psI
oRIFIce sIze
1/8” 3/16” 1/4” 5/16” 3/8” 1/2” 5/8”
11/4” X 11/4”
0.5 549 721 8151 752 862 1066 11912 831 1097 1317 1599 16143 658 1019 1364 1614 1881 16465 392 909 1395 1850 2116 2335 1661
71/2 486 1097 1787 2351 2524 2477 166110 580 1317 2132 2665 2680 2821 185020 987 1928 2508 2821 2978 297840 1348 2821 3448 2978 313560 1881 3292 376280 2430 3448
125 3527 3762
Model 143-80 Second Stage Service Regulators (continued)
Propane Gas Chart*143-80-2, and 143-80-2hp —capacity in 1000’s of btu’s of undiluted propane (1.5 Specific Gravity, 14.65 psia, 60ºF)
pIpe sIze
Inlet pRessuRe
psI
oRIFIce sIze
1/8” 3/16” 1/4” 5/16” 3/8” 1/2” 5/8”
3/4” X 3/4”
0.5 533 705 7991 752 784 799 8312 831 878 893 909 9403 658 940 972 987 1019 10505 392 878 1097 1129 1144 1207 1238
71/2 486 1097 1317 1348 1379 1411 141110 580 1301 1489 1520 1567 1599 159920 831 1881 1912 1944 1959 199140 1348 2461 2085 2100 227360 1861 2602 238380 2351 2680
125 2821 2978
* Note 1: Propane chart is a mathematical extrapolation using 0.63 correction factor and 2,488 btu/hr = 1 cubic foot from NFPA-58, 2008.
Victor/F.w. Webb has over 125 outside sales people available to help you. If you
need technical expertise, we’ve got it!
![Page 20: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/20.jpg)
14 victormfg.com
Regulators 1SECTION
Gas Equipment Catalog
Model 243 Second Stage Service RegulatorsThese large capacity service regulators are designed and built for commercial, industrial and gas distribution work. They are right at home in such places as factories and foundries, district regulator stations, commercial laundries and laundromats, motels-hotels and apartments, bakeries, restaurants, schools, churches and hospitals.The versatile 243 is used for all kinds of gas fueled equipment. . .boilers, burners, furnaces, ovens, heaters, kilns, engines, air conditioners, etc.Remarkable field versatility results from the union connection between the fully interchangeable bodies and diaphragm-case assemblies. They are easy to install, adjust, inspect and service in all kinds of piping arrangements.while used primarily for natural gas services, Model 243 regulators perform equally well on LPG vapor, air, dry cO2, nitrogen and other inert gas applications.
basic Models
outlet pressure Ranges and springs
Maximum Inlet pressure, psig
MFR# descRIptIon sIzes teMpeRatuRe lIMIt Webb#243-12-224
12” Diaphram with Internal Relief11/2” Body
-20ºF to 150ºF
181915243-12-232 2” Body 181916243-8-220
8” Diaphram with Internal Relief11/4” Body 181917
243-8-224 11/2” Body 181918243-8-232 2” Body 259165243-8HP-2 Special High Pressure Regulator 2” Body 247442
spRInG coloR
outlet pRessuRe RanGespRInG paRt# Webb#243-12 243-8
Red-Black — 31/2” to 61/2” W.C. 143-82-021-00 181954Blue-Black — 5” to 81/2” W.C. 143-82-021-01 —
Green-Black — 6” to 14” W.C. 143-82-021-02 —Red 31/2” to 61/2” W.C. — 143-16-21-03 188870Blue 5” to 81/2” W.C. — 143-16-021-04 —
Green 6” to 14” W.C. 12” to 28” W.C. 143-16-021-05 254467Orange-Black 10” to 18” W.C. — 143-16-021-11 —
Orange 12” to 28” W.C. 1 to 2 psi 143-16-021-06 181953Black 1 to 2 psi 2 to 41/2 psi* 143-16-021-07 181934
Cadium 11/2 to 3 psi 3 to 61/2” psi* 143-16-021-08 188871Cadium —
6 to 10 psi*143-16-021-08 —
White — 143-16-021-13 —Clamping Plate 143161020100 308181
capacities for other GasesFor capacities ( in ScFH) of other gases, multiply the capacity values by a correction factor from the table below:
otheR Gases
specIFIc GRavIty
coRRectIon FactoR
Propane 1.53 0.63
ReGulatoR Model and sIze
oRIFIce sIze and anGle
11/4” 11/4”* 1” 1”* 3/4” 3/4” 1/2” 3/8” 1/4” .207”
30 10 30 10 30 10 10 10 10 1011/4”, 243-12 15 25 25 40 — 60 100 125 125 —11/2”, 243-12 15 25 25 40 — 60 100 125 125 —
2”, 243-12 15 25 25 40 40 60 100 125 125 —11/4”, 243-8 — — — — — 40 80 100 125 12511/2”, 243-8 — — 25 — — 40 80 100 125 125
2”, 243-8 — — 25 — 40 40 80 100 125 —11/4”, 243-8HP — — — — — 40 80 100 125 —11/2”, 243-8HP — — 25 — — 40 80 100 125 —
2”, 243-8HP — — 25 — — 40 80 100 125 —
* Good for use in 243 8HP Series only
![Page 21: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/21.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
reg
ula
to
rs
& a
cc
es
so
rie
s
1
Regulators
15
SECTION
1243 VariationsInternal Relief ValvesThe 243 is available with an internal relief valve (IRV). It’s a built-in safety device for providing a limited level of over-pressure protection.Like any relief valve, an IRV must be carefully sized.Internal relief valves are not available in the high pressure Model 243-8HP.
Natural Gas Chart11/2” Model 243-12-2 capacity table in scFh of natural Gas (0.6 Specific Gravity — 14.65 psia — 60°F)
Model 243 Capacity Tables
pIpe sIze
Inlet pRessuRe
(psI)
oRIFIce sIze and valve anGle
11/4” 1” 3/4” 1/2” 3/8” 1/4”
30 30 10 10 10 10
11/2”
Set Point 11” W.C.
2” W.C. Droop Green Spring 6” to 14” W.C.143-16-021-05
1 2700 2300 1900 1100 750 4002 4000 3500 2700 1900 1200 6005 6000 5600 4500 3500 2100 100010 8800 8200 6500 5500 2900 140015 10000 9800 7700 6800 3800 175025 11500 9700 8100 5100 240040 11500 9700 7100 320060 12500 11500 9300 440080 12000 10500 5600100 12500 11000 7000125 11000 8000
pIpe sIze
Inlet pRessuRe
(psI)
oRIFIce sIze and valve anGle
11/4” 1” 3/4” 1/2” 3/8” 1/4”
30 30 10 10 10 10
11/2”
Set Point 11” W.C.
2” W.C. Droop Green Spring 6” to 14” W.C.143-16-021-05
1 4232 3605 2978 1724 1176 6272 6270 5486 4232 2978 1881 9405 9405 8778 7053 5486 3292 156710 13793 12853 10188 8621 4546 219415 15674 15361 12069 10659 5956 274325 18026 15204 12696 7994 376240 18026 15204 11129 501660 19593 18026 14577 689780 18809 16458 8778100 19593 17242 10972125 17242 12540
Propane Gas Chart11/2” Model 243-12-2 capacity table in 1000’s of btu’s or undiluted propane Gas (1.5 Specific Gravity — 14.65 psia — 60°F)
pIpe sIze
Inlet pRessuRe
(psI)
oRIFIce sIze and valve anGle
11/4” 1” 3/4” 1/2” 3/8” 1/4”
30 30 10 10 10 10
11/2”
Set Point 1 psi .31 psi
Droop Orange Spring 12” to
28” W.C.143-16-021-06
2 6500 5000 4000 2000 1300 5005 8000 7500 6000 4000 2200 100010 9000 8500 8000 5500 3000 140015 12000 11500 10000 7000 4000 180025 13500 11500 9500 5500 240040 13000 11000 7400 330060 15000 13500 10000 450080 15000 13000 6000100 16000 14000 7000125 14000 8500
pIpe sIze
Inlet pRessuRe
(psI)
oRIFIce sIze and valve anGle
11/4” 1” 3/4” 1/2” 3/8” 1/4”
30 30 10 10 10 10
11/2”
Set Point 1 psi .31 psi Droop Orange
Spring 12” to 28” W.C.
143-16-021-06
2 10188.4 7837.2 6269.76 3134.88 2037.67 783.725 12539.5 11755.8 9404.64 6269.76 3448.37 1567.44
10 14107 13323.2 12539.5 8620.92 4702.32 2194.4215 18809.3 18025.6 15674.4 10972.1 6269.76 2821.3925 21160.4 18025.6 14890.7 8620.92 3761.8640 20376.7 17241.8 11599.1 5172.5560 23511.6 21160.4 15674.4 7053.4880 23511.6 20376.7 9404.64
100 25079 21944.2 10972.1125 21944.2 13323.2
![Page 22: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/22.jpg)
16 victormfg.com
Regulators 1SECTION
Gas Equipment Catalog
Natural Gas Chart11/2” Model 243-12-2 capacity table in scFh of natural Gas (0.6 Specific Gravity — 14.65 psia — 60°F)
pIpe sIze
Inlet pRessuRe
(psI)
oRIFIce sIze and valve anGle
11/4” 1” 3/4” 1/2” 3/8” 1/4”
30 30 10 10 10 10
11/2”
Set Point 1 psi .2 psi
Droop Black Spring
1 to 2 psi143-16-021-07
2 2800 2450 1500 1200 850 5005 5500 5100 3700 2400 1600 95010 8000 7500 5700 4000 2700 140015 10000 9100 7100 5300 3700 175025 11000 9300 7300 5100 240040 11000 9300 7100 320060 12500 11000 9300 460080 12500 10500 5600100 13000 11000 7000125 11000 8000
pIpe sIze
Inlet pRessuRe
(psI)
oRIFIce sIze and valve anGle
11/4” 1” 3/4” 1/2” 3/8” 1/4”
30 30 10 10 10 10
11/2”
Set Point 1 psi .2 psi
Droop Black Spring
1 to 2 psi143-16-021-07
2 4389 3840 2351 1881 1332 7845 8621 7994 5800 3762 2508 148910 12540 11756 8934 6270 4232 219415 15674 14264 11129 8307 5800 274325 17242 14577 11442 7994 376240 17242 14577 11129 501660 19593 17242 14577 721080 19593 16458 8778100 20377 17242 10972125 17242 12540
Propane Gas Chart11/2” Model 243-12-2 capacity table in 1000’s of btu’s or undiluted propane Gas (1.5 Specific Gravity — 14.65 psia — 60°F)
pIpe sIze
Inlet pRessuRe
(psI)
oRIFIce sIze and valve anGle
11/4” 1” 3/4” 1/2” 3/8” 1/4”
30 30 10 10 10 10
11/2”
Set Point 2 psi .6 psi
Droop Cadium Spring
11/2 to 3 psi143-16-021-08
5 6000 5300 4100 2700 1700 90010 10000 9300 7100 4700 2900 140015 13000 12000 8800 6200 3800 170025 14500 11000 8600 5200 240040 13500 11000 7100 320060 15000 13500 10000 460080 15000 12000 5600100 16000 12000 7000125 12000 8000
pIpe sIze
Inlet pRessuRe
(psI)
oRIFIce sIze and valve anGle
11/4” 1” 3/4” 1/2” 3/8” 1/4”
30 30 10 10 10 10
11/2”
Set Point 2 psi .6 psi
Droop Cadium Spring
11/2 to 3 psi143-16-021-08
5 9405 8307 6427 4232 2665 141110 15674 14577 11129 7367 4546 219415 20377 18809 13793 9718 5956 266525 22728 17242 13480 8151 376240 21160 17242 11129 501660 23512 21160 15674 721080 23512 18809 8778100 25079 18809 10972125 18809 12540
Model 243 Capacity Tables (continued)
Victor/F.w. Webb can provide
customized training for your company! Just ask your victor sales person.
![Page 23: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/23.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
reg
ula
to
rs
& a
cc
es
so
rie
s
1
Regulators
17
SECTION
1Model 243 Capacity Tables (continued)
Natural Gas Chart2” Model 243-12-2 capacity table in scFh of natural Gas (0.6 Specific Gravity — 14.65 psia — 60°F)
pIpe sIze
Inlet pRessuRe
(psI)
oRIFIce sIze and valve anGle
11/4” 1” 3/4” 3/4” 1/2” 3/8” 1/4”
30 30 30 10 10 10 10
2”
Set Point 11” W.C. 2” W.C. Droop Green Spring 6” to
14” W.C.143-16-021-05
1 3400 3000 2100 1950 1150 750 4002 5600 4700 3700 3400 2000 1200 6005 10500 9000 7800 6900 3500 2100 1000
10 13000 13000 12000 9200 5500 3200 160015 14000 14000 15000 10500 7000 4000 180025 15000 20000 12000 500 5300 240040 20000 14500 12500 7500 320060 15500 13000 10000 440080 14000 12000 5600
100 14000 12000 7000125 12000 8000
pIpe sIze
Inlet pRessuRe
(psI)
oRIFIce sIze and valve anGle
11/4” 1” 3/4” 3/4” 1/2” 3/8” 1/4”
30 30 30 10 10 10 10
2”
Set Point 11” W.C. 2” W.C. Droop Green Spring 6” to
14” W.C.143-16-021-05
1 5329 4702 3292 3057 1803 1176 6272 8778 7367 5800 5329 3135 1881 9405 16458 14107 12226 10815 5486 3292 1567
10 20377 20377 18809 14420 8621 5016 250815 21944 21944 23512 16458 10972 6270 282125 23512 31349 18809 784 8307 376240 31349 22728 19593 11756 501660 24295 20377 15674 689780 21944 18809 8778
100 21944 18809 10972125 18809 12540
pIpe sIze
Inlet pRessuRe
(psI)
oRIFIce sIze and valve anGle
11/4” 1” 3/4” 3/4” 1/2” 3/8” 1/4”
30 30 30 10 10 10 10
2”
Set Point 1 psi
.31 psi Droop Orange
Spring 12” to 28” W.C.
143-16-021-06
2 6500 5000 4000 4000 2000 1300 5005 8000 7500 6000 6000 4000 2200 1000
10 9000 8500 8000 8000 5500 3000 140015 12000 11000 10000 10000 7000 4000 180025 13500 12500 11500 9500 5500 240040 14000 13000 11000 7400 330060 15000 13500 10000 450080 15000 13000 6000
100 16000 14000 7000125 14000 8500
pIpe sIze
Inlet pRessuRe
(psI)
oRIFIce sIze and valve anGle
11/4” 1” 3/4” 3/4” 1/2” 3/8” 1/4”
30 30 30 10 10 10 10
2”
Set Point 1 psi
.31 psi Droop Orange
Spring 12” to 28” W.C.
143-16-021-06
2 10188 7837 6270 6270 3135 2038 7845 12540 11756 9405 9405 6270 3448 1567
10 14107 13323 12540 12540 8621 4702 219415 18809 17242 15674 15674 10972 6270 282125 21160 19593 18026 14891 8621 376240 21944 20377 17242 11599 517360 23512 21160 15674 705380 23512 20377 9405
100 25079 21944 10972125 21944 13323
Propane Gas Chart2” Model 243-12-2 capacity table in 1000’s of btu’s of undiluted propane Gas (1.5 Specific Gravity — 14.65 psia — 60°F)
Victor/F.w. Webb can help you
layout a petite 7
base board system.
![Page 24: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/24.jpg)
18 victormfg.com
Regulators 1SECTION
Gas Equipment Catalog
Natural Gas Chart11/4” Model 243-8-2 capacity table in scFh of natural Gas (0.6 Specific Gravity — 14.65 psia — 60°F)
Model 243 Capacity Tables (continued)
pIpe sIze
Inlet pRessuRe
(psI)
oRIFIce sIze and valve anGle
3/4” 1/2” 3/8” 1/4” 0.207”
10 10 10 10 10
11/4”
Set Point 11” wc. 2” wc
Droop Green Spring 6” to
14” wc143-82-021-02
1 1150 1000 650 3002 1850 1350 1000 450 3505 2500 2200 1750 800 55010 2900 2700 2450 1300 90015 3700 2950 2600 1700 110025 4250 4000 3300 2400 150040 5300 4200 3800 3200 210060 4850 4400 4400 290080 5850 5600 5600 3700
100 6000 7000 4500125 8000 5600
pIpe sIze
Inlet pRessuRe
(psI)
oRIFIce sIze and valve anGle
3/4” 1/2” 3/8” 1/4” 0.207”
10 10 10 10 10
11/4”
Set Point 11” wc. 2” wc
Droop Green Spring 6” to
14” wc143-82-021-02
1 1803 1567 1019 4702 2900 2116 1567 705 5495 3919 3448 2743 1254 862
10 4546 4232 3840 2038 141115 5800 4624 4075 2665 172425 6662 6270 5173 3762 235140 8307 6583 5956 5016 329260 7602 6897 6897 454680 9170 8778 8778 5800
100 9405 10972 7053125 12540 8778
pIpe sIze
Inlet pRessuRe
(psI)
oRIFIce sIze and valve anGle
3/4” 1/2” 3/8” 1/4” 0.207”
10 10 10 10 10
11/4”
Set Point 1” psi Droop Orange
Spring 1 to 2 psi143-16-021-06
2 1850 1150 850 4505 2100 1700 1350 750 50010 2700 2000 1950 1300 80015 3150 3100 2050 1700 100025 4150 3250 2850 2400 150040 5300 3800 3600 3200 210060 4600 4250 4400 290080 4650 5600 5600 3700
100 6000 7000 4500125 8000 5600
pIpe sIze
Inlet pRessuRe
(psI)
oRIFIce sIze and valve anGle
3/4” 1/2” 3/8” 1/4” 0.207”
10 10 10 10 10
11/4”
Set Point 1” psi Droop Orange
Spring 1 to 2 psi143-16-021-06
2 2900 1803 1332 7055 3292 2665 2116 1176 784
10 4232 3135 3057 2038 125415 4937 4859 3213 2665 156725 6505 5094 4467 3762 235140 8307 5956 5643 5016 329260 7210 6662 6897 454680 7289 8778 8778 5800
100 9405 10972 7053125 12540 8778
Propane Gas Chart11/4” Model 243-8-2 capacity table in 1000’s of btu’s of undiluted propane Gas (1.5 Specific Gravity — 14.65 psia — 60°F)
![Page 25: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/25.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
reg
ula
to
rs
& a
cc
es
so
rie
s
1
Regulators
19
SECTION
1
Natural Gas Chart2” Model 243-12-2 capacity table in scFh of natural Gas (0.6 Specific Gravity — 14.65 psia — 60°F)
Model 243 Capacity Tables (continued)
pIpe sIze
Inlet pRessuRe
(psI)
oRIFIce sIze and valve anGle
11/4” 1” 3/4” 3/4” 1/2” 3/8” 1/4”
30 30 30 10 10 10 10
2”
Set Point 1 psi .2 psi
Droop Black Spring 1 to
2 psi143-16-021-07
2 3350 3000 2000 1900 1200 1000 5005 6600 5900 4200 3900 2400 1600 1000
10 11000 10000 7600 6500 4100 2800 145015 13000 12000 9300 8300 5600 3800 170025 15000 16500 11000 8500 5300 240040 20000 14000 12500 7500 340060 15500 13000 10000 440080 14000 12000 5600
100 14000 12000 7000125 12000 8000
pIpe sIze
Inlet pRessuRe
(psI)
oRIFIce sIze and valve anGle
11/4” 1” 3/4” 3/4” 1/2” 3/8” 1/4”
30 30 30 10 10 10 10
2”
Set Point 1 psi .2 psi
Droop Black Spring 1 to 2 psi
143-16-021-07
2 5251 4702 3135 2978 1881 1567 7845 10345 9248 6583 6113 3762 2508 1567
10 17242 15674 11913 10188 6427 4389 227315 20377 18809 14577 13010 8778 5956 266525 23512 25863 17242 13323 8307 376240 31349 21944 19593 11756 532960 24295 20377 15674 689780 21944 18809 8778
100 21944 18809 10972125 18809 12540
pIpe sIze
Inlet pRessuRe
(psI)
oRIFIce sIze and valve anGle
11/4” 1” 3/4” 3/4” 1/2” 3/8” 1/4”
30 30 30 10 10 10 10
2”
Set Point 2 psi .6 psi
Droop Cadium
Spring 11/2 to 3 psi
143-16-021-08
5 8200 7400 5200 4800 2900 1900 90010 12500 11300 8700 7800 4800 3000 140015 15500 14500 11500 10000 6500 3800 170025 18000 16500 13500 9000 5300 240040 20000 16500 12500 7600 340060 16500 15500 10000 460080 16000 12000 5600
100 16000 12000 7000125 12000 8000
pIpe sIze
Inlet pRessuRe
(psI)
oRIFIce sIze and valve anGle
11/4” 1” 3/4” 3/4” 1/2” 3/8” 1/4”
30 30 30 10 10 10 10
2”
Set Point 2 psi .6 psi
Droop Cadium
Spring 11/2 to 3 psi
143-16-021-08
5 12853 11599 8151 7524 4546 2978 141110 19593 17712 13637 12226 7524 4702 219415 24295 22728 18026 15674 10188 5956 266525 28214 25863 21160 14107 8307 376240 31349 25863 19593 11913 532960 25863 24295 15674 721080 25079 18809 8778
100 25079 18809 10972125 18809 12540
Propane Gas Chart2” Model 243-12-2 capacity table in 1000’s of btu’s of undiluted propane Gas (1.5 Specific Gravity — 14.65 psia — 60°F)
![Page 26: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/26.jpg)
20 victormfg.com
Regulators 1SECTION
Gas Equipment Catalog
Model 243 Capacity Tables (continued)
Natural Gas Chart2” and 11/2” Model 243-8-2 capacity table in scFh of natural Gas (0.6 Specific Gravity — 14.65 psia — 60°F)
pIpe sIze
Inlet pRessuRe
(psI)
oRIFIce sIze and valve anGle
1” 3/4” 1/2” 3/8” 1/4” 0.207
30 10 10 10 10 10
2” and 11/2”
Set Point 11” W.C.
2” W.C. Droop Green Spring 6” to 14” W.C.143-82-021-02
1 1650 1150 1000 650 3002 2700 2000 1400 1000 450 3505 4800 3800 2600 1750 900 60010 7000 5400 4200 2800 1300 90015 9000 7400 5500 3600 1700 110025 11000 8800 7500 5100 2400 150040 11000 9600 7100 3200 210060 11000 9300 4400 290080 11500 10500 5600 3700100 11000 7000 4500125 8000 5600
pIpe sIze
Inlet pRessuRe
(psI)
oRIFIce sIze and valve anGle
1” 3/4” 1/2” 3/8” 1/4” 0.207
30 10 10 10 10 10
11/2”
Set Point 2 psi .2 Droop
Orange Spring 1 to 2 psi
143-16-021-06
2 2100 1650 1200 850 4505 4000 3200 2100 1300 850 55010 6500 5200 3100 2200 1300 80015 8400 6500 4400 3000 1700 100025 11000 11000 6500 4400 2400 150040 8600 6700 3200 210060 10500 9000 4400 290080 11500 10500 5600 3700100 11000 7000 4500125 8000 5600
pIpe sIze
Inlet pRessuRe
(psI)
oRIFIce sIze and valve anGle
1” 3/4” 1/2” 3/8” 1/4” 0.207
30 10 10 10 10 10
2”
Set Point 2 psi .2 Droop
Orange Spring 1 to 2 psi
143-16-021-06
2 2400 1800 1700 1200 850 4505 4000 3400 3300 2200 1300 90010 7000 6000 5400 3500 2200 140015 11000 9000 7000 4600 3100 170025 14500 15000 10000 7400 4800 240040 17500 12000 10500 7000 340060 11000 9500 460080 10500 5600
100 11000 7000125 8000
Propane Gas Chart*2” and 11/2” Model 243-8-2 capacity table in 1000’s of btu’s of undiluted propane Gas (1.5 Specific Gravity — 14.65 psia — 60°F)
pIpe sIze
Inlet pRessuRe
(psI)
oRIFIce sIze and valve anGle
1” 3/4” 1/2” 3/8” 1/4” 0.207
30 10 10 10 10 10
2” and 11/2”
Set Point 11” W.C. 2” W.C. Droop
Green Spring 6” to 14” W.C.143-82-021-02
1 2586 1803 1567 1019 4702 4232 3135 2194 1567 705 5495 7524 5956 4075 2743 1411 94010 10972 8464 6583 4389 2038 141115 14107 11599 8621 5643 2665 172425 17242 13793 11756 7994 3762 235140 17242 15047 11129 5016 329260 17242 14577 6897 454680 18026 16458 8778 5800100 17242 10972 7053125 12540 8778
pIpe sIze
Inlet pRessuRe
(psI)
oRIFIce sIze and valve anGle
1” 3/4” 1/2” 3/8” 1/4” 0.207
30 10 10 10 10 10
11/2”
Set Point 2 psi .2 Droop
Orange Spring 1 to 2 psi
143-16-021-06
2 3292 2586 1881 1332 7055 6270 5016 3292 2038 1332 86210 10188 8151 4859 3448 2038 125415 13166 10188 6897 4702 2665 156725 17242 13480 10188 6897 3762 235140 17242 13480 10502 5016 329260 16458 14107 6897 454680 18026 16458 8778 5800100 17242 10972 7053125 12540 8778
pIpe sIze
Inlet pRessuRe
(psI)
oRIFIce sIze and valve anGle
1” 3/4” 1/2” 3/8” 1/4” 0.207
30 10 10 10 10 10
2”
Set Point 2 psi .2 Droop
Orange Spring 1 to 2 psi
143-16-021-06
2 3762 2821 2665 1881 1332 7055 6270 5329 5173 3448 2038 141110 10970 9405 8484 5486 3448 219415 17242 14107 10972 7210 4859 266525 22728 23512 15674 11599 7524 376240 27430 18809 16458 10972 532960 19593 14891 721080 21160 16458 8778
100 17242 10972125 1250
* Note 1: Propane chart is a mathematical extrapolation using 0.63 correction factor and 2,488 btu/hr = 1 cubic foot from NFPA-58, 2008.
![Page 27: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/27.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
reg
ula
to
rs
& a
cc
es
so
rie
s
1
Regulators
21
SECTION
1
Natural Gas Chart11/4”, 11/2”, 2” Models 243-8hp capacity table in scFh of natural Gas(0.6 Specific Gravity — 14.65 psia — 60°F)
pIpe sIze*Inlet
pRessuRe (psI)
oRIFIce sIze and valve anGle
3/4” 1/2” 3/8” 1/4”
10 10 10 10
11/4”
Set Point 5 psi Droop Cadium Spring
3 to 61/2 psi143-16-021-08
10 3300 2050 2000 130015 3400 3100 2200 170025 4400 3650 3050 240040 5800 3800 3200 320060 4400 4100 440080 4500 5300 5600100 6000 7000125 8000
pIpe sIze*Inlet
pRessuRe (psI)
oRIFIce sIze and valve anGle
1” 3/4” 1/2” 3/8” 1/4”
30 10 10 10 10
11/2”
Set Point 5 psi Droop Cadium Spring
3 to 61/2 psi143-16-021-08
10 6000 5500 3200 2300 130015 8600 6500 4400 3200 170025 12000 9300 6100 4800 240040 12000 8500 6100 320060 10000 8700 440080 11000 10000 5600100 11000 7000125 8000
pIpe sIze
Inlet pRessuRe
(psI)
oRIFIce sIze and valve anGle
1” 3/4” 1/2” 3/8” 1/4”
30 10 10 10 10
2”
Set Point 5 psi Droop Cadium Spring
3 to 61/2 psi143-16-021-08
10 6000 5500 3200 2400 130015 8600 6500 4400 3200 170025 13000 8200 6100 4800 240040 12000 8700 6100 340060 10000 8700 460080 11500 10000 5600100 11000 7000125 8000
Propane Gas Chart**11/4”, 11/2”, 2” Models 243-8hp capacity table in 1000’s of btu’s undiluted propane Gas (1.5 Specific Gravity — 14.65 psia — 60°F)
pIpe sIze*Inlet
pRessuRe (psI)
oRIFIce sIze and valve anGle
3/4” 1/2” 3/8” 1/4”
10 10 10 10
11/4”
Set Point 5 psi 1 psiDroop Cadium Spring
3 to 61/2 psi143-16-021-08
10 5173 3213 3135 203815 5329 4859 3448 266525 6897 5721 4781 376240 9091 5956 5016 501660 6897 6427 689780 7053 8307 8778100 9405 10972125 12540
pIpe sIze*Inlet
pRessuRe (psI)
oRIFIce sIze and valve anGle
1” 3/4” 1/2” 3/8” 1/4”
30 10 10 10 10
11/2”
Set Point 5 psi 1 psiDroop Cadium Spring
3 to 61/2 psi143-16-021-08
10 9405 8621 5016 3605 203815 13480 10188 6897 5016 266525 18809 14577 9561 7524 376240 18809 13323 9561 501660 15674 13637 689780 17242 15674 8778100 17242 10972125 12540
pIpe sIze
Inlet pRessuRe
(psI)
oRIFIce sIze and valve anGle
1” 3/4” 1/2” 3/8” 1/4”
30 10 10 10 10
2”
Set Point 5 psi 1psiDroop Cadium Spring
3 to 61/2 psi143-16-021-08
10 9405 8621 5016 3762 203815 13480 9405 6897 5016 266525 20377 12853 9561 7524 376240 18809 13637 9561 532960 15674 13637 721080 17242 15674 8778100 17242 10972125 12540
* Special Order
** Propane chart is a mathematical extrapolation using 0.63 correction factor and 2,488 btu/hr = 1 cubic foot from NFPA-58, 2008.
Model 243 High Pressure Capacity Tables
![Page 28: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/28.jpg)
22 victormfg.com
Regulators 1SECTION
Gas Equipment Catalog
Gas Appliance Pressure RegulatorsMaxitrol company manufactures a complete line of gas appliance regulators for domestic, commercial, and industrial needs.
Balance Valve Design — 210D, E & GMain burner and pilot applications.The balanced valve 210 Series are designed for use with intermediate pressure. The balancing diaphragm virtually eliminates inlet pressure effect, which makes them ideal for applications where supply pressure fluctuates.
210D, E & GMFR# pIpe sIzes capacItIes to
Inlet pRessuRes to
outlet pRessuRes
210D1”, 11/4”, 11/2”, 2”, 21/2”, & 3”
6500 CFH10 psi (700 mbar) 1.0” to 42” W.C.
(2.5 to 105 mbar)210E 12000 CFH210G 26000 CFH
MFR# body sIzes Qty. peR case Webb#210D-1 1” 4 201676210D-1010-114 11/4” 4 201679210D-112 11/2” 4 201678210D-36-24 11/2” 4 199526210D412-24 11/2” 4 —210E-2 2” 2 198116210E412-24 11/2” 2 201673210E412-32 2” 2 201674
Natural Gas Chart11/2” & 2” stock spring violet 4-12” w.c. Model 210e capacity table in scFh of natural Gas (0.6 Specific Gravity — 14.65 psia — 60°F)
pIpe sIze
Inlet pRessuRe (psI)
set poInt 2” W.c.
set poInt 4” W.c.
set poInt 6” W.c.
set poInt 9” W.c.
set poInt 12” W.c.
set poInt 16” W.c.
11/2”
8” w.c. 4450 3650 2550.5 psi 6300 5750 5150 4050.75 psi 7000 7500 7050 6300 5450 40501 psi 7000 8800 8500 7950 7250 6300
1.5 psi 7000 8800 8500 10450 9950 92502 psi 7000 8800 8500 10500 10500 105003 psi 7000 8800 8500 10500 10500 105005 psi 7000 8800 8500 10500 10500 10500
7.5 psi 7000 8800 8500 10500 10500 1050010 psi 7000 8800 8500 10500 10500 10500
pIpe sIze
Inlet pRessuRe (psI)
set poInt 2” W.c.
set poInt 4” W.c.
set poInt 6” W.c.
set poInt 9” W.c.
set poInt 12” W.c.
set poInt 16” W.c.
2”
8” w.c. 5150 4200 2950.5 psi 7250 6650 5950 4700
.75 psi 8000 8650 8150 7250 6300 47001 psi 8000 10000 9850 9150 8400 7250
1.5 psi 8000 10000 10000 12000 11500 107002 psi 8000 10000 10000 12000 12000 120003 psi 8000 10000 10000 12000 12000 120005 psi 8000 10000 10000 12000 12000 12000
7.5 psi 8000 10000 10000 12000 12000 1200010 psi 8000 10000 10000 12000 12000 12000
![Page 29: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/29.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
reg
ula
to
rs
& a
cc
es
so
rie
s
1
Regulators
23
SECTION
1Gas Appliance Pressure Regulators (continued)
Propane Gas Chart*11/2” and 2” stock spring violet 4-12” w.c. Model 120e capacity table in 1000’s of btu’s of undiluted propane Gas (1.5 Specific Gravity — 14.65 psia — 60°F)
Natural Gas Chart1” & 11/4” stock spring violet 4-12” w.c. Model 210d capacity table in scFh of natural Gas (0.64 Specific Gravity — 14.65 psia — 60°F)
pIpe sIze
Inlet pRessuRe (psI)
set poInt 2” W.c.
set poInt 4” W.c.
set poInt 6” W.c.
set poInt 9” W.c.
set poInt 12” W.c.
set poInt 16” W.c.
11/2”
8” w.c. 6975 5721 3997.5 psi 9875 9013 8072 6348.75 psi 10972 11756 11050 9875 8543 63481 psi 10972 13793 13323 12461 11364 9875
1.5 psi 10972 13793 13793 16380 15596 144992 psi 10972 13793 13793 16458 16458 164583 psi 10972 13793 13793 16458 16458 164585 psi 10972 13793 13793 16458 16458 16458
7.5 psi 10972 13793 13793 16458 16458 1645810 psi 10972 13793 13793 16458 16458 16458
pIpe sIze
Inlet pRessuRe (psI)
set poInt 2” W.c.
set poInt 4” W.c.
set poInt 6” W.c.
set poInt 9” W.c.
set poInt 12” W.c.
set poInt 16” W.c.
1”
8” w.c. 2400 1900 1300.5 psi 3400 3100 2700 2200.75 psi 3500 4000 3800 3400 2900 22001 psi 3500 4000 4500 4300 3900 3400
1.5 psi 3500 4000 4500 4800 4800 50002 psi 3500 4000 4500 4800 4800 50003 psi 3500 4000 4500 4800 4800 50005 psi 3500 4000 4500 4800 4800 5000
7.5 psi 3500 4000 4500 4800 4800 500010 psi 3500 4000 4500 4800 4800 5000
pIpe sIze
Inlet pRessuRe (psI)
set poInt 2” W.c.
set poInt 4” W.c.
set poInt 6” W.c.
set poInt 9” W.c.
set poInt 12” W.c.
set poInt 16” W.c.
2”
8” w.c. 8072 6583 4624.5 psi 11364 10423 9326 7367.75 psi 12540 13558 12775 11364 9875 73671 psi 12540 15674 15439 1432 13166 11364
1.5 psi 12540 15674 15674 18809 18026 167722 psi 12540 15674 15674 18809 18809 188093 psi 12540 15674 15674 18809 18809 188095 psi 12540 15674 15674 18809 18809 18809
7.5 psi 12540 15674 15674 18809 18809 1880910 psi 12540 15674 15674 18809 18809 18809
pIpe sIze
Inlet pRessuRe (psI)
set poInt 2” W.c.
set poInt 4” W.c.
set poInt 6” W.c.
set poInt 9” W.c.
set poInt 12” W.c.
set poInt 16” W.c.
11/4”
8” w.c. 3000 2400 1700.5 psi 4000 3905 3400 2700.75 psi 4000 5000 4700 4200 3700 27001 psi 4000 5000 5000 5300 4900 4200
1.5 psi 4000 5000 5000 6000 6000 60002 psi 4000 5000 5000 6000 6000 60003 psi 4000 5000 5000 6000 6000 60005 psi 4000 5000 5000 6000 6000 6000
7.5 psi 4000 5000 5000 6000 6000 600010 psi 4000 5000 5000 6000 6000 6000
* Propane chart is a mathematical extrapolation using 0.63 correction factor and 2,488 btu/hr = 1 cubic foot from NFPA-58, 2008.
![Page 30: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/30.jpg)
24 victormfg.com
Regulators 1SECTION
Gas Equipment Catalog
Gas Appliance Pressure Regulators (continued)
Natural Gas Chart11/2” stock spring violet 4-12” w.c. Model 210d capacity table in scFh of natural Gas (0.64 Specific Gravity — 14.65 psia — 60°F)
Propane Gas Chart*1”, 11/4” and 11/2” stock spring violet 4-12” w.c. Model 210d capacity table in 1000’s of btu’s of undiluted propane Gas (1.5 Specific Gravity — 14.65 psia — 60°F)
pIpe sIze
Inlet pRessuRe (psI)
set poInt 2” W.c.
set poInt 4” W.c.
set poInt 6” W.c.
set poInt 9” W.c.
set poInt 12” W.c.
set poInt 16” W.c.
11/2”
8” w.c. 3100 2500 1800.5 psi 4000 4000 3600 2800.75 psi 4000 5000 5000 4400 3800 28001 psi 4000 5000 5000 5600 5100 4400
1.5 psi 4000 5000 5000 6000 6000 65002 psi 4000 5000 5000 6000 6000 65003 psi 4000 5000 5000 6000 6000 65005 psi 4000 5000 5000 6000 6000 6500
7.5 psi 4000 5000 5000 6000 6000 650010 psi 4000 5000 5000 6000 6000 6500
pIpe sIze
Inlet pRessuRe (psI)
set poInt 2” W.c.
set poInt 4” W.c.
set poInt 6” W.c.
set poInt 9” W.c.
set poInt 12” W.c.
set poInt 16” W.c.
1”
8” w.c. 3762 2978 2038.5 psi 5329 4859 4232 3448
.75 psi 5486 6270 5956 5329 4546 34481 psi 5486 6270 7053 6740 6113 5329
1.5 psi 5486 6270 7053 7524 7524 78372 psi 5486 6270 7053 7524 7524 78373 psi 5486 6270 7053 7524 7524 78375 psi 5486 6270 7053 7524 7524 7837
7.5 psi 5486 6270 7053 7524 7524 783710 psi 5486 6270 7053 7524 7524 7837
pIpe sIze
Inlet pRessuRe (psI)
set poInt 2” W.c.
set poInt 4” W.c.
set poInt 6” W.c.
set poInt 9” W.c.
set poInt 12” W.c.
set poInt 16” W.c.
11/4”
8” w.c. 4702 3762 2665.5 psi 6270 6121 5329 4232.75 psi 6270 7837 7837 6583 5800 42321 psi 6270 7837 7837 8307 7080 6583
1.5 psi 6270 7837 7837 9405 9405 94052 psi 6270 7837 7837 9405 9405 94053 psi 6270 7837 7837 9405 9405 94055 psi 6270 7837 7837 9405 9405 9405
7.5 psi 6270 7837 7837 9405 9405 940510 psi 6270 7837 7837 9405 9405 9405
pIpe sIze
Inlet pRessuRe (psI)
set poInt 2” W.c.
set poInt 4” W.c.
set poInt 6” W.c.
set poInt 9” W.c.
set poInt 12” W.c.
set poInt 16” W.c.
11/2”
8” w.c. 4869 3919 2821.5 psi 6270 6270 5643 4389.75 psi 6270 7837 7837 6897 5956 43891 psi 6270 7837 7837 8778 7994 6897
1.5 psi 6270 7837 7837 9405 9405 101882 psi 6270 7837 7837 9405 9405 101883 psi 6270 7837 7837 9405 9405 101885 psi 6270 7837 7837 9405 9405 10188
7.5 psi 6270 7837 7837 9405 9405 1018810 psi 6270 7837 7837 9405 9405 10188
* Propane chart is a mathematical extrapolation using 0.63 correction factor and 2,488 btu/hr = 1 cubic foot from NFPA-58, 2008.
![Page 31: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/31.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
reg
ula
to
rs
& a
cc
es
so
rie
s
1
Regulators
25
SECTION
1
RV52 & RV53
RV61
RV81 & RV91
RV111
RV131
Straight-Thru-Flow-DesignRV52, RV53, RV61, RV81, RV91, RV111, RV1311/2”, 3/4”, 11/4”, 11/2”, 2”, 21/2”, 3”, & 4”Main burner onlyThe straight-thru-flow RV Series, size for size, has the highest pressure drop capacity of any regulator design available. They are best used when supply pressure is low enough to cause concern about capacity.Gases: Natural, manufactured, mixed, liquified petroleum, or LP gas-air mixture.Features:• Greater accuracy — higher pressure drop capacity.• Outlet pressure available to 42” w.c.• Available in full range of pipe sizes from 1/2” to 4”.• All models tapped with NPT vent bosses.• A.G.A. Rated (except RV131) — 1/2 psi (35 mbar).
MFR# pIpe sIzes capacItIes to Inlet
pRessuRes tooutlet
pRessuResRV52 1/2” & 3/4” 900 CFH
1/2 psi (35 mbar) 1.0” to 12” W.C.RV53 3/4” & 1” 130 CFHRV61 1” & 11/4” 2500 CFH
1 psi (70 mbr) 1.0” to 22” W.C.RV81 11/4”, 11/2”, 2” & 21/2” 4500 CFHRV91 7500 CFHRV111 21/2” & 3” 1 psiRV131 4” Flanged 2 psi 2 psi (140 mbr) 3.0” to 42” W.C.
MFR# body sIzes Qty. peR case Webb#RV52-12 1/2” 25 108537RV52-34 3/4” 25 196920RV53-1 1” 25 118670RV53-34 3/4” 25 108742RV61-1 1” 18 185908RV61-114 11/4” 18 188934RV81-114 11/4” 4 196848RV91-2 2” 4 109623
Natural Gas ChartStraight thru flow RV regulator (Appliance or combustion regulators)capacity table in cFh’s of natural Gas (0.64 Specific Gravity — 14.65 psia — 60°F)
MFR# pIpe sIzecsa Max
pRessuRe dRop In W.c.0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 2 3 4
RV52 1/2” or 3/4” 450 151 214 362 302 338 370 400 427 453 478 676 828 956RV53 3/4” or 1” 710 217 306 375 433 484 530 573 612 650 684 968 1185 1369RV61 1” or 11/4” 1100 379 536 675 759 848 929 1004 1073 1138 1200 1742 2134 2464RV81 11/4” or 11/2” 2500 780 1102 1350 1559 1743 1909 2062 2204 2339 2465 3465 4269 4929RV91 2” or 21/2” 3275 1212 1714 2100 2424 2711 2969 3208 3429 3637 3834 5422 6640 7668RV111 21/2” or 3” 7500 2742 3878 4750 5485 6718 6718 7256 7757 8227 8572 14134 14862 17161RV131 4” — 4734 6695 8200 9468 11596 11596 12390 13390 13390 14971 21172 25930 29942
MFR# pIpe sIzecsa Max
pRessuRe dRop In W.c.0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 2 3 4
RV52 1/2” or 3/4” 705 237 335 411 473 530 580 627 669 710 749 1060 1298 1498RV53 3/4” or 1” 1113 340 480 588 679 759 831 898 959 1019 1072 1517 1857 2146RV61 1” or 11/4” 1724 594 840 1058 1190 1329 1456 1574 1682 1784 1881 2730 3345 3862RV81 11/4” or 11/2” 3919 1223 1727 2116 2444 2732 2992 3232 3455 3666 3864 5463 6691 7726RV91 2” or 21/2” 5133 1900 2687 3292 3799 4249 4654 5028 5375 5701 6010 8499 10408 12019RV111 21/2” or 3” 11756 4298 6079 7445 8597 9612 10530 11373 12159 12895 13436 22154 23295 26899RV131 4” — 7420 10494 12853 14841 16593 18176 19632 20988 22261 23466 33186 40644 46932
Propane Gas Chart*Straight thru flow RV regulator (Appliance or combustion regulators)capacity table in 1000’s of btu’s of undiluted propane Gas (1.5 Specific Gravity — 14.65 psia — 60°F)
* Propane chart is a mathematical extrapolation using 0.63 correction factor and 2,488 btu/hr = 1 cubic foot from NFPA-58, 2008.
![Page 32: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/32.jpg)
26 victormfg.com
Regulators 1SECTION
Gas Equipment Catalog
325-5ALX
Attention: To comply with the ANSI Z21-80 Standard for Line Pressure Regulators, installations exceeding 2-psi nominal require a tested and approved over-pressure protection device (OPD) for use with the regulator. (Over-pressure protection is not required for supply pressures up to and including 2-psi.)
325 Series L-Model Line Regulators & OPDs, #2 Inlet RegulatorsFeatures:• cSA certified for up to 5-psi inlet pressure.• Over-pressure protection device (OPD) to limit downstream pressure in case
of regulator failure.• Maxitrol OPD approved and tested with the regulator.• Regulators or OPD’s can be ordered as separate items — or as a factory assembled unit.• Self-aligning valve with lever action for dead end regulator lockup.• Optional vent limiter eliminates the need to run vent piping to an outside area.Benefits:• Meets new ANSI standard Z21-80 for line pressure regulators — for use on piping
systems such as cSST or semi-rigid copper tubing up to 5-psi.• OPD provides required downstream over-pressure protection for supply pressures
in excess of 2-psi.• Pounds to inches regulator provides precise control from pilot flows to full
regulator capacity.• Meets many utility specifications.
Outlet Pressure Range (all models)Certified spring – 7-11 in W.C.
MFR#body sIzes
Qty. peR case Webb#
325-3L-12 1/2” 50 252139325-3L-38 3/8” 50 252138325-5AL-1 1” 18 252142325-5AL-12 1/2” 18 252140325-5AL-34 3/4” 18 252141325-7AL-114 11/4” 4 224151325-7AL-112 11/2” 4 224152
MFR# descRIptIon Webb#
MXT325-3L-38LP LP REG 3/8" IPS AT 11"WC W/VNT LIMITER 432833
MXT325-3L-12LP LP REG 1/2" IPS AT 11"WC W/VNT LIMITER 432832
MXT325-5AL-12LP LP REG 1/2" IPS AT 11"WC W/VNT LIMITER 432834
MXT325-5AL-34LP LP REG 3/4" IPS AT 11"WC W/VNT LIMITER 432836
MXT325-5AL-1LP LP REG 1" IPS AT 11"WC W/VNT LIMITER 432835
MXT325-7AL-114LP LP REG 1-1/4" IPS AT 11"WC W/VNT LIMITER 432838
MXT325-7AL-112LP LP REG 1-1/2" IPS AT 11"WC W/VNT LIMITER 432837
Natural Gas ChartModel 325l series 2 psI Max Inlet capacity table in scFh of natural Gas (0.64 Specific Gravity — 14.65 psia — 60°F)
MFR# pIpe sIzeoutlet
pRessuRe1/2 psI Inlet
3/4 psI Inlet
1 psI Inlet
11/2 psI Inlet
2 psI Inlet
Max load MultIple
applIances
Max IndIvIdual
applIance load
325-3L 3/8” or 1/2” 7” W.C. 145 200 250 250 250 250 14010” W.C. 110 180 230 250 250 250 140
325-5AL 1/2” 7” W.C. 335 425 425 425 425 425 30010” W.C. 250 420 425 425 425 425 300
325-5AL 3/4” or 1” 7” W.C. 335 475 550 550 550 550 30010” W.C. 250 420 535 550 550 550 300
325-7AL 11/4” or 11/2” 7” W.C. 690 970 1000 1000 1000 1000 90010” W.C. 520 860 1000 1000 1000 1000 900
Special Order For 325 Series With OPD
Vent Limiter 12A09
AccessoriesVent Limiting MeansBall check permits free inhalation for fast regulator diaphragm response on opening cycle, but limits gas escapement to within ANSI standards should a diaphragm rupture.
MFR# descRIptIon Webb#12A04 Optional Automatic Vent Limiting Device for RV48, RV52, RV53, RV61 7752712A06 Optional Vent Limiting Orifice for RV48, RV52, RV53, RV61 192793
12A09 Optional Automatic Vent Limiting Device for 325-3, 325-3L, 325-3LX, OPD48, OPD600, 325-3L47 (reg. only), 325-3L48 (reg. & OPD), 325-5AL48 (OPD only), 325-5AL600 (OPD only) 109780
12A39 Optional Automatic Vent Limiting Device for 325-5A, 325-5AL, 325-ALX,325-5AL48 (reg. only), 325-5AL600 (reg. only) 192794
12A49 Optional Automatic Vent Limiting Device for 325-7L, 325-7AL 43674613A15 Outdoor Vent Protector for 3L and 5AL 24635013A25 Outdoor Vent Protector for 3L and 5AL 433028
7” Wc less vent limiter 11” Wc With vent limiter
![Page 33: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/33.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
reg
ula
to
rs
& a
cc
es
so
rie
s
1
Regulators
27
SECTION
1325 Series L-Model Line Regulators & OPDs, #2 Inlet Regulators
Natural Gas ChartModel 325 With opd capacity table in scFh of natural Gas (0.64 Specific Gravity — 14.65 psia — 60°F)
MFR# pIpe sIzeoutlet
pRessuRe1/2 psI Inlet
3/4 psI Inlet
1 psI Inlet
5 psI Inlet
Max load MultIple
applIances
Max IndIvIdual
applIance load
325-3L47 3/8” 7” W.C. 125 125 125 125 125 12510” W.C. 100 125 125 125 125 125
325-3L47 1/2” 7” W.C. 125 125 125 125 125 12510” W.C. 105 125 125 125 125 125
325-3L48 1/2” 7” W.C. 160 200 200 200 200 20010” W.C. 120 200 200 200 200 200
325-5AL48 1/2” 7” W.C. 235 235 235 235 235 23510” W.C. 235 235 235 235 235 235
325-5AL48 3/4” 7” W.C. 320 320 320 320 320 32010” W.C. 245 320 320 320 320 320
325-5AL600 3/4” 7” W.C. 345 425 425 425 425 42510” W.C. 260 425 425 425 425 425
325-5AL600 1” 7” W.C. 375 465 465 465 465 46510” W.C. 285 465 465 465 465 465
Propane Gas Chart*Model 325 with opd capacity table in 1000’s of btu’s of undiluted propane Gas (1.5 Specific Gravity — 14.65 psia — 60°F)
MFR# pIpe sIzeoutlet
pRessuRe1/2 psI Inlet
3/4 psI Inlet
1 psI Inlet
5 psI Inlet
Max load MultIple
applIances
Max IndIvIdual
applIance load
325-3L47 3/8” 7” W.C. 196 196 196 196 196 19610” W.C. 157 196 196 196 196 196
325-3L47 1/2” 7” W.C. 196 196 196 196 196 19610” W.C. 165 196 196 196 196 196
325-3L48 1/2” 7” W.C. 251 313 313 313 313 31310” W.C. 188 313 313 313 313 313
325-5AL48 1/2” 7” W.C. 368 368 368 368 368 36810” W.C. 368 368 368 368 368 368
325-5AL48 3/4” 7” W.C. 502 502 502 502 502 50210” W.C. 384 502 502 502 502 502
325-5AL600 3/4” 7” W.C. 541 666 666 666 666 66610” W.C. 408 666 666 666 666 666
325-5AL600 1” 7” W.C. 588 729 729 729 729 72910” W.C. 447 729 729 729 729 729
* Propane chart is a mathematical extrapolation using 0.63 correction factor and 2,488 btu/hr = 1 cubic foot from NFPA-58, 2008.
MFR# pIpe sIzeoutlet
pRessuRe1/2 psI Inlet
3/4 psI Inlet
1 psI Inlet
11/2 psI Inlet
2 psI Inlet
Max load MultIple
applIances
Max IndIvIdual
applIance load
325-3L 3/8” or 1/2” 7” W.C. 227 313 392 392 392 392 21910” W.C. 172 282 361 392 392 397 219
325-5AL 1/2” 7” W.C. 525 666 666 666 666 666 47010” W.C. 392 658 666 666 666 666 470
325-5AL 3/4” or 1” 7” W.C. 525 745 862 862 862 862 47010” W.C. 392 658 839 862 862 862 470
325-7L 11/4” or 11/2” 7” W.C. 1082 1520 1567 1567 1567 1567 141010” W.C. 815 1348 1567 1567 1567 1567 1410
Propane Gas Chart*Model 325l series 2 psI capacity table in 1000’s of btu’s of undiluted propane Gas (1.5 Specific Gravity — 14.65 psia — 60°F)
* Propane chart is a mathematical extrapolation using 0.63 correction factor and 2,488 btu/hr = 1 cubic foot from NFPA-58, 2008.
![Page 34: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/34.jpg)
28 victormfg.com
Regulators 1SECTION
Gas Equipment Catalog
RV12
RV20
RV47 & CV47
RV48
Rubber Seat Poppet Design Appliance Regulators — RV12, RV20, RV47 & CV47 and RV48Main burner and pilot applications
MFR# pIpe sIzes capacItIes to Inlet
pRessuRes tooutlet
pRessuResRV12 1/8” 25 CFH 1/2 psi (35 mbar)
1.0” to 12” W.C.RV20 1/4” & 3/8” 65 CFH 1/2 psiRV47 & CV47 3/8” & 1/2” 125 CFH
1/2 psi (35 mbr)RV48 1/2” & 3/4” 250 CFH
MFR# body sIzes Qty. peR case Webb#RV20L-38 3/8” 100 185902RV47CL-12 1/2” 50 185903RV47CL-38 3/8” 50 188932RV47L-12 1/2” 50 197256RV47L-38 3/8” 50 188933RV48CL-12 1/2” 50 185905RV48CL-34 3/4” 50 185904RV48L-12 1/2” 50 185907RV48L-34 3/4” 50 185906
MFR#body sIzes
Qty. peR case
std. spRInG set poInt Webb#
RV20L-38 3/8" 100 3-5" wc 4" 185902RV48CL-12 1/2" 50 None fixed 4 or 10" 185903RV47CL-38 3/8" 50 None fixed 4 or 10" 188932RV47L-12 1/2" 50 4-12" 11" 197256RV47L-38 3/8" 50 4-12" 11" 188933RV48CL-12 1/2" 50 None fixed 4 or 10" 185905RV48CL-34 3/4" 50 None fixed 4 or 10" 185904RV48L-12 1/2" 50 4-12" 11" 185907RV48L-34 3/4" 50 4-12" 11" 185906RV48-12 1/2" 50 3-6" 4" 77528RV48-34 3/4" 50 3-6" 4" 77529
MFR# pIpe sIze
Max capacIty at .3” W.c.
pRessuRe dRop
suGGested Max supply
FoR MaIn buRneR only
suGGested Max supply FoR MaIn
buRneR only and pIlot
Max IndIvIdual load WIth FIxed
oRIFIce vent lIMIteR
Max IndIvIdual load WIth ball
check vent lIMIteR
RV12 1/8” 15 30 25 20 —RV20 1/4” or 3/8” 30 65 50 30 —RV47 3/8” or 1/2” 30 125 90 40 90RV47C 3/8” or 1/2” 60 125 125 40 125RV48 1/2” 130 230 230 40 160RV48 3/4” 150 230 250 40 160RV48C 1/2” 130 400 275 40 160RV48C 3/4” 150 400 275 40 160
Natural Gas Chartpoppet Rv Regulator (appliance Regulators) capacity table in scFh of natural Gas (0.64 Specific Gravity — 14.65 psia — 60°F) (Min. Capacity on all models is 150 btu/hr)
![Page 35: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/35.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
reg
ula
to
rs
& a
cc
es
so
rie
s
1
Regulators
29
SECTION
1
Propane Gas Chart*poppet Rv Regulator (appliance Regulators) capacity table in 1000’s of btu’s of undiluted propane Gas (1.5 Specific Gravity — 14.65 psia — 60°F)
MFR# pIpe sIze
Max capacIty at .3” W.c.
pRessuRe dRop
suGGested Max supply
FoR MaIn buRneR only
suGGested Max supply FoR MaIn
buRneR only and pIlot
Max IndIvIdual load WIth FIxed
oRIFIce vent lIMIteR
Max IndIvIdual load WIth ball
check vent lIMIteR
RV12 1/8” 23 47 39 31 —RV20 1/4” or 3/8” 47 102 78 47 —RV47 3/8” or 1/2” 47 196 141 63 141RV47C 3/8” or 1/2” 94 196 196 63 196RV48 1/2” 204 361 361 63 251RV48 3/4” 235 361 392 63 251RV48C 1/2” 204 627 392 63 251RV48C 3/4” 235 627 392 63 251
* Propane chart is a mathematical extrapolation using 0.63 correction factor and 2,488 btu/hr = 1 cubic foot from NFPA-58, 2008.
MFR# descRIptIon use WIth ReGulatoR Webb #MXTR325C10-1022 Spring Red 10-22 325-3 325-3 185891MXTR325C10-1530 Spring Yellow 15-30 325C 325-3 197075MXT325E-10A-1022 Spring Red 10-22” 325-5A 325-5A 110108MXTR325E10-26A Springs 2 to 6 lbs 325-5A 309740MXTR325E10-412 Spring Violet 4-12 325-5A 185893MXTR325E10-P12 Spring Tagged 325-5A 185894MXTR4810-512 Spring Blue 5-12 RV48 RV48 185889MXTR6110-1022 Maxitrol Spring 10 to 12 RV61 254238MXTR8110-1022 Spring Red RV81/210D 192815MXTR8110-1530 Spring Yellow 15-30 210D RV81/210D 196945MXTR8110-2042 Spring Black 20-42 RV81/210D 185897MXTR8110-412 Spring Violet 4-12 RV RV81/210D 196956MXTR8110-512 Spring Blue 5-12 RV81/210D 185898MXTR8110-515 Spring Green 5-15 RV881 210 RV81/210D 196987MXTR9110-1022 Spring Red 10-22 RV91/210E 185899MXTR9110-1530 Spring Yellow 15-30” 210E RV91/210E 196947MXTR9110-412 Spring Violet 4-12” Spring RV91/210E 199275MXTR9110-512 Spring Blue 5-12 RV91/210E 309737
Rubber Seat Poppet Design Appliance Regulators — RV12, RV20, RV47 & CV47 and RV48
Victor/F.w. Webb offers webbConnect! you can order, check current pricing
and inventory 24/7!
![Page 36: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/36.jpg)
30 victormfg.com
Cylinder & Service Valves 2SECTION
Gas Equipment Catalog
Heavy Duty Cylinder Valves for Vapor WithdrawalThis heavy duty cylinder valve is designed for vapor withdrawal of DOT cylinders up to 100 lbs. propane capacity. It is used in domestic hookups, with RV’s and as a heavy duty barbeque cylinder valve.
9103D11.6
MFR#CONTAINER CONNECTION
SERVICE CONNECTION
FIXED LIQUID LEVEL VENT VALVE STYLE
DIP TUBE LENGTH
WITH DEFLECTOR
PRESSURE RELIEF VALVE
SETTING
FOR USE IN CYLINDERS
WITH PROPANE CAPACITY UP TO
9103D10.63/4” M. NPT F. POL
CGA 510 Knurled 10.6”
375 PSIG 100 lbs.9103D11.6 11.6”
MFR#
APPROXIMATE FILLING RATE LIQUID FLOW, GPMACCESSORIES
WEBB#PRESSURE DROP ACROSS VALVES
10 PSIG 25 PSIG 50 PSIG 100 PSIG POL PLUG
9103D10.612.7 20.3 29.0 41.3 N970P
162726
9103D11.6 162727
Cylinder Valve for RV and Small ASME System Vapor WithdrawalDesigned especially for vapor withdrawal service in small ASME containers with surface area up to 23.8 square feet. UL flow capacity is 645 CFM/air, per NFPA 58.
Cavagna OPD ValveType 1 valves intended for DOT cylinders up to 40 lbs. LP Gas capacity. This valve has a vapor service outlet, relief valve, captive fixed liquid level gauge, and an overfill prevention device.
Outlet thread:Dip tube length:Setting pressure:Flow limiter:Plastic cap:Inlet thread:Pressure relief valve:Gas type:Packaging:Availability:
Type 1 ACME and POL4.0 inches375 PSINoNo3/4YesLP-Gas28Yes
MFR#CONTAINER CONNECTION
SERVICE CONNECTION
FIXED LIQUID LEVEL
VENT VALVE STYLE
PRESSURE RELIEF VALVE
SETTING
FOR USE IN CYLINDERS
WITH PROPANE CAPACITY
UP TO
FLOW CAPACITY SCFM/AIR WEBB#
9106CO 3/4” M. NPT F. POL CGA 510 None 312 PSIG ASME Tanks* 645 186998* Surface area up to 23.8 square feet.
9106CO
MFR# SIzE WEBB#
VCT80-8169 20# 395314
VCT80-9-890-8128 30# 401280
VCT80-9-890-8185 40# 399370
VCT80-8169
![Page 37: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/37.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
2
va
lves
& a
cc
es
so
rie
sCylinder & Service Valves
31
2SECTION
Service Valves for ASME and DOT Containersor Fuel Line ApplicationsDesigned especially for vapor withdrawal service on ASME and DOT containers or in fuel line applications. Since none of these valves have an integral pressure relief valve, they may only be used as an accessory valve on containers that have an independent pressure relief valve sufficient for that container’s capacity.
“Dual” Cylinder Valve for Simultaneous Liquid and Vapor WithdrawalThe dual cylinder valve was designed especially for industrial uses. It increases the cylinder’s flexibility by permitting DOT cylinders up to 100 lbs. propane capacity to be used interchangeably or simultaneously for either liquid or vapor withdrawal.
MFR#BONNET STYLE
CONTAINER CONNECTION
SERVICE CONNECTION
FIXED LIQUID LEVEL VENT VALVE
APPROXIMATE FILLING RATE LIQUID FLOW, GPM
WEBB#
PRESSURE DROP ACROSS VALVE
10 PSIG 25 PSIG 50 PSIG 100 PSIG
9101C1
Standard3/4” M. NPT F. POL
CGA 510
No 8.8 12.4 15.8 21.7 186993
9101DT11.1Yes 8.6 12.7 16.3 22.3
273828
9101DT11.7 273829
9101R11.7 MultiBonnet Yes 7.6 11.7 15.2 20.6 162724
MFR#CONTAINER
CONNECTION
SERVICE CONNECTION FIXED LIQUID LEVEL VENT VALVE STYLE
LIQUID WITHDRAWALTUBE LENGTHVAPOR LIQUID
8556 3/4” M. NPT F. POL CGA 510 CGA 555 None 44”
* Closing flows based on 3/8” O.D. withdrawal tube 44” long or less attached.IMPORTANT: 1/4” O.D. pigtails or POL connections for 1/4” O.D. pigtails should not be used with these valves.NOTES: To ensure proper functioning and maximum protection from excess flow valves, the cylinder valve should be fully opened and backseated when in use. These valves incorporate an excess flow valve. Refer to L-500/Section F, for complete information regarding selection, operation and testing of excess flow valves.
* To ensure proper functioning and maximum protection from excess flow valves, the cylinder valve should be fully opened and backseated when in use. NOTE: These valves incorporate an excess flow valve. Refer to L-500/Section F, for complete information regarding selection, operation and testing of excess flow valves.
MFR#
PRESSURE RELIEF VALVE
SETTING
FOR USE IN CYLINDERS
WITH PROPANE CAPACITY UP TO
APPROXIMATE FILLING RATE LIQUID FLOW, GPM CLOSING FLOW (LP-GAS)*
WEBB#
PRESSURE DROP ACROSS VALVES VAPOR
LIQUID10
PSIG25
PSIG50
PSIG100
PSIG25 PSIG INLET
100 PSIG INLET
9107K8A 375 PSIG 100 lbs. 3.3 5.4 7.7 11.1 525SCFH
1,000 SCFH 1.7 GPM 162728
MFR#
PRESSURE RELIEF VALVE
SETTING
FOR USE IN CYLINDERS
WITH PROPANE CAPACITY UP TO
APPROXIMATE FILLING RATE LIQUID FLOW, GPM
LIQUID CLOSING FLOW* (LP-GAS) WEBB#
PRESSURE DROP ACROSS VALVES10 PSIG 25 PSIG 50 PSIG 100 PSIG
8556 375 PSIG 100 lbs. 6.6 10.0 14.5 21.0 2.3 GPM 189194
Cylinder Valve for Liquid WithdrawalEquipped with excess flow valves and liquid withdrawal tubes, they are designed for liquid withdrawal of DOT cylinders up to 100 lbs. propane capacity. They are most often used with heavy BTU loads found in industrial uses.
9107K8A With Dip Tube
MFR#CONTAINER
CONNECTIONSERVICE
CONNECTION
FIXED LIQUID LEVEL VENT VALVE STYLE
DIP TUBE LENGTH WITH DEFLECTOR
LIQUID WITHDRAWAL TUBE LENGTH
9107K8A 3/4” M. NPT CGA 555 Knurled 11.6” 44”
NOTE: These valves incorporate an excess flow valve. Refer to L-500/Section F, for complete information regarding selection, operation and testing of excess flow valves.
9101R11.79101C
![Page 38: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/38.jpg)
32 victormfg.com
Cylinder & Service Valves 2SECTION
Gas Equipment Catalog
Service Valve for DOT Fork Lift ContainersDesigned especially for vapor or liquid withdrawal service on DOT fork lift containers. Valves with 1.5 GPM closing flow are for use in small and medium size lift truck applications, while those with 2.6 GPM closing flow are for large lift trucks and gantry crane type vehicles. Since none of these valves have an integral pressure relief valve, they may only be used as an accessory valve on containers that have an independent pressure relief valve sufficient for that cylinders capacity.The integral excess flow valve found in all these service valves helps prevent excessive product loss in the event of fuel line rupture.When installed for liquid withdrawal, the 9101P6 Series has provisions for attachment of a liquid withdrawal tube. The 9101P5 Series must be installed in containers that have provisions for a separate liquid withdrawal.
Service Valves for ASME Motor Fuel ContainersDesigned specifically for vapor or liquid withdrawal service on ASME motor fuel containers. Since none of these valves have an integral pressure relief valve, they may only be used as an accessory valve on containers that have an independent pressure relief valve sufficient for that container’s capacity.The integral excess flow valve found in all these service valves helps prevent excessive product loss in the event of fuel line rupture.When installed for liquid withdrawal, the 9101H6 has provisions for attachment of a liquid withdrawal tube. All other valves must be installed in containers that have provisions for a separate liquid withdrawal.
9101P5
9101P6
9101H6
9101H5
9101Y5H
MFR#CONTAINER CONNECTION
SERVICE CONNECTION
LIQUID
WITHDRAWAL CONNECTION
CLOSING FLOW (LP-GAS)VAPOR
LIQUID (GPM)
25 PSIG INLET (SCFH)
100 PSIG INLET (SCFH)
9101P5
3/4” M. NPT 3/8” M. NPTNone
430 900 1.59101P5H 550 1050 2.69101P6
1/4” NPT430 900 1.5
9101P6H 550 1050 2.6
MFR#
APPROXIMATE FILLING RATE LIQUID FLOW, GPM ACCESSORIES
WEBB#PRESSURE DROP ACROSS VALVES ACME CHECK CONNECTORS
10 PSIG 25 PSIG 50 PSIG 100 PSIG MALE FEMALE CAP9101P5
5.0 7.6 10.7 14.9
7141M 7141F7141M-40
or 7141FP
9101P5H
9101P64.5 7.2 10.3 14.8
9101P6H
MFR#CONTAINER
CONNECTIONSERVICE
CONNECTION
LIQUID WITHDRAWAL CONNECTION
CLOSING FLOW (LP GAS)
WEBB#
VAPORLIQUID GPM
25 PSIG INLET (SCFH)
100 PSIG INLET (SCFH)
9101H5*
3/4” M. NPT* SAE Flare
None 765** 1300** 3.6** 162499
9101H6* 1/4” NPT 550**** 1050**** 2.6**** 189199
9101Y5H* 60° Angle * SAE Flare None 550** 1050** 3.6** 162500
*Heavy-duty models. **Based on 3/8” O.D. pigtail, 20” long or less, connected to valve outlet. For greater lengths the pigtail must have a larger O.D. ***Same as (**) . In addition, 1/4” O.D. pigtails or POL connections for 1/4” O.D. should not be used with this valve. ****Based on 3/8” O.D. pigtail: 20” long or less, connected to valve outlet. Also based on 1/4” pipe size dip tube, 42” long or less, attached to special inlet connection. For longer pigtail lengths, the diameter of the pigtail must be increased.
162720162721186995190685
To ensure proper functioning and maximum protection from excess flow valves, the cylinder valve should be fully opened and backseated when in use.
To ensure proper functioning and maximum protection from excess flow valves, the cylinder valve should be fully opened and backseated when in use.
![Page 39: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/39.jpg)
33TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Multivalve Assemblies
33
2SECTION
2
va
lves
& a
cc
es
so
rie
s
ASME Multivalves® for Vapor WithdrawalThese Multivalves® are designed for use in single opening ASME containers equipped with a 21/2” M. NPT riser. They can be used with underground ASME containers up to 639 sq. ft. surface area, and above ground ASME containers up to 192 sq. ft. surface area. A separate opening is required for liquid withdrawal. The MultiBonnet® is standard on this valve. The MultiBonnet® allows quick and easy repair of bonnet.
ASME Multivalves® for Vapor WithdrawalThese Multivalves® provide vapor withdrawal and filling of ASME containers. A separate pressure relief valve is required in addition to this valve. The MultiBonnet® is standard on this valve. MultiBonnet® allows quick and easy repair of bonnet.
* Dip tube not installed, may be cut by customer to desired length.** Since these Multivalves® have not integral pressure relief valves, they can be used on any ASME container with an independent relief device sufficient for that tank’s capacity.
* Dip tube not installed, may be cut by customer to desired length.
For specific repair parts, see the end of this section.
G8475RW
8593AR16.0
MFR#
APPROXIMATE FILLING RATE LIQUID FLOW, GPMPRESSURE DROP ACROSS VALVES
10 PSIG 25 PSIG 50 PSIG 100 PSIGG8475RV
42 72 98 125G8475RW
MFR#
APPROXIMATE FILLING RATE LIQUID FLOW, GPM
WEBB#PRESSURE DROP ACROSS VALVES
10 PSIG 25 PSIG 50 PSIG 100 PSIG
8593AR16.0 42 72 98 125 162498
MFR#CONTAINER
CONNECTIONSERVICE
CONNECTIONFILLING
CONNECTION
VAPOR EQUALIzING CONNECTION FLOAT
GAUGE FLANGE OPENING
CONNECTION SIzE
UL LISTED CLOSING FLOW
G8475RV21/2” F. NPT F. POL CGA 510 13/4” M. Acme 11/4” M. Acme 4200 CFH
at 100 PSIG Fits “Junior” SizeG8475RW
MFR#CONTAINER
CONNECTIONSERVICE
CONNECTIONFILLING
CONNECTION
VAPOR EQUALIzING
CONNECTION FIXED LIQUID LEVEL VENT VALVE STYLE
DIP TUBE
LENGTH
FOR USE IN CONTAINERS
WITH SURFACE
AREA UP TO:CONNECTION
SIzE
UL LISTED
CLOSING FLOW
8593AR16.0 11/2” M. NPT F. POL CGA 510 13/4” M. Acme 11/4” M. Acme 4200 CFH at 100 PSIG Knurled 16”* **
MFR#
FIXED LIQUID LEVEL VENT VALVE
STYLEDIP TUBE LENGTH
PRESSURE RELIEF VALVE FOR USE IN *CYLINDERS WITH
SURFACE AREA UP TO WEBB#SETTING MFR#
FLOW CAPACITYUL ASME
G8475RVKnurled 30”* 250 PSIG
M3131G 2020 SCFM/air
1939 SCFM/air
83 sq. ft. Above Ground 276 sq. ft. Underground 187104
G8475RW MV3132G 3995 SCFM/air n/a 192 sq. ft. Above Ground
639 sq. ft. Underground 190680
![Page 40: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/40.jpg)
34 victormfg.com
Multivalve Assemblies 2SECTION
Gas Equipment Catalog
DOT Multivalves® for Liquid WithdrawalThese Multivalves® permit liquid withdrawal from DOT cylinders with up to 100 lbs. propane capacity. They eliminate unnecessary cylinder handling when servicing high volume loads and allow on-site filling into the vapor space without interrupting gas service.
DOT Multivalves® for Vapor WithdrawalThese Multivalves® permit vapor withdrawal from DOT cylinders with up to 200 lbs. propane capacity. They allow on-site cylinder filling without interrupting gas service. The MultiBonnet® option allows quick and easy repair of bonnet.
8555D11.6
8555DL11.6
MFR#
APPROXIMATE FILLING RATE LIQUID FLOW, GPMPRESSURE DROP ACROSS VALVES
10 PSIG 25 PSIG 50 PSIG 100 PSIG8555DL11.6 8 23 34 42
MFR#
APPROXIMATE FILLING RATE LIQUID FLOW, GPM
WEBB#PRESSURE DROP ACROSS VALVES
10 PSIG 25 PSIG 50 PSIG 100 PSIG
6555R11.6
8 23 34 42
359339
6555R12.0 —
8555D10.6 162732
8555R10.6 162740
8555D11.6 162733
8555R11.6 162741
8555DT10.6 273825
8555DT11.6 273826
8555DT8.2 273827
MFR#CONTAINER
CONNECTIONSERVICE
CONNECTIONFILLING
CONNECTION
FIXED LIQUID LEVEL VENT VALVE STYLE
DIP TUBE LENGTH
WITH DEFLECTOR
8555DL11.6 3/4” M.NPT CGA 555* 13/4” M. Acme Knurled 11.6”
MFR#
LIQUID WITHDRAWAL TUBE LENGTH
PRESSURE RELIEF VALVE
SETTING
FOR USE IN CYLINDERS WITH
PROPANE CAPACITY UP TO
LIQUID CLOSING FLOW (LP. GAS)*** WEBB#
8555DL11.6 44” 375 PSIG 100 lbs.** 1.7 GPM 162734
T = Threadsealent
MFR# BONNET STYLE APPLICATIONFOR USE IN CONTAINERS
WITH SIzE UP TODIP TUBE LENGTH WITH DEFLECTOR
CONTAINER CONNECTION
6555R11.6 MultiBonnet ASME Containers 25 ft. Surface Area or 60 Gallons Water Capacity 11.6”
3/4” M. NPT
8555D10.6 Standard
DOT Containers 200 lbs. Propane
10.6”8555R10.6 MultiBonnet8555D11.6 Standard
11.6”8555R11.6 MultiBonnet8555DT10.6
Standard10.6”
8555DT11.6 11.6”8555DT8.2 8.2”
*Use adapter 12982 to connect to pipe threads. **Per CGA Pamphlet S-1.1. ***To ensure proper functioning and maximum protection from integral excess flow valves, the cylinder valve should be fully opened and backseated when in use.
![Page 41: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/41.jpg)
35TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Multivalve Assemblies
35
2SECTION
2
va
lves
& a
cc
es
so
rie
s
MFR#CONTAINER
CONNECTIONSERVICE
CONNECTIONFILLING
CONNECTION
FIXED LIQUID LEVEL VENT VALVE STYLE
DIP TUBE LENGTH
WITH DEFLECTOR
8555DL11.6 3/4” M.NPT CGA 555* 13/4” M. Acme Knurled 11.6”
DOT Multivalves® for Liquid Withdrawal (continued)
MFR#SERVICE
CONNECTIONFILLING
CONNECTION
FIXED LIQUID LEVEL VENT
STYLE
PRESSURE RELIEF VALVE
WEBB#SETTING
FLOW CAPACITY*
UL LISTING ASME
6555R11.6
F. POL CGA 510 13/4” M. Acme Knurled
250 PSIG793
SCFM/air
700 SCFM/
air359339
8555D10.6
375 PSIG n/a n/a
162732
8555R10.6 162740
8555D11.6 162733
8555R11.6 162741
8555DT10.6 273825
8555DT11.6 273826
8555DT8.2 273827T = Threadsealent* Per CGA Pamphlet S-1.1.
T = Threadsealent
DOT and ASME Multivalves® for Vapor WithdrawalThese Multivalves® permit vapor withdrawal from ASME containers up to 50 sq. ft. surface area and DOT containers up to 420 lbs. propane capacity. They allow on-site cylinder filling without interrupting gas service. The MultiBonnet® option allows quick and easy repair of bonnet.
6543A11.7MFR#
APPROXIMATE FILLING RATE LIQUID FLOW, GPM
WEBB#PRESSURE DROP ACROSS VALVES
10 PSIG 25 PSIG 50 PSIG 100 PSIG
6532A12.011 16 23
28
—
6532R12.0 162735
6542A12.023 32 46
373827
6542R12.0 162737
6533A11.711 16 23
162729
6533R11.7 162736
6543A11.1
23 32 46
162730
6543R11.1 162738
6543A11.7 162731
6543R11.7 162739
6543AT10.3 — — — — 273821
6543AT11.7 — — — — 275093
![Page 42: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/42.jpg)
36 victormfg.com
Multivalve Assemblies 2SECTION
Gas Equipment Catalog
MFR# BONNET STYLE APPLICATIONCONTAINER
CONNECTIONSERVICE
CONNECTIONFILLING
CONNECTIONFIXED LIQUID LEVEL VENT VALVE STYLE
6532A12.0 Standard
ASME*3/4” M. NPT
F.POL CGA 510 13/4” M. Acme Knurled
6532R12.0 MultiBonnet6542A12.0 Standard
1” M. NPT6542R12.0 MultiBonnet6533A11.7 Standard
DOT
3/4” M. NPT6533R11.7 MultiBonnet6543A11.1 Standard
1” M. NPT6543R11.1 MultiBonnet6543A11.7 Standard6543R11.7 MultiBonnet
MFR#DIP TUBE LENGTH WITH DEFLECTOR
PRESSURE RELIEF VALVE SETTING
FOR USE IN CYLINDERS WITH PROPANE CAPACITY**
FOR USE IN CONTAINERS WITH SURFACE AREA UP TO*** WEBB#
6532A12.0
12.0” 250 PSIG —
43 sq. ft.—
6532R12.0 162735
6542A12.053 sq. ft.
373827
6542R12.0 162737
6533A11.711.7”
375 PSIG 420 lbs. Propane —
162729
6533R11.7 162736
6543A11.111.1”
162730
6543R11.1 162738
6543A11.711.7”
162731
6543R11.7 162739
DOT and ASME Multivalves® for Vapor Withdrawal (continued)
* UL rated flow capacities are 6532A 12.0-1180 SCFM/air, 6542A 12.0-1530 SCFM/air. ** Per CGA Pamphlet S-1.1. *** From NFPA 58, Appendix D.
ASME Multivalves® for Vapor WithdrawalThese compact Multivalves® are especially suited for vapor withdrawal of ASME containers where compact groupings of components are necessary. Separate filler valves and pressure relief valves are required. MultiBonnet® allows quick and easy repair of bonnet.
* Since these Multivalves® have no integral pressure relief valves, they can be used on any ASME container with an independent relief device sufficient for that tank’s capacity.
7556R12.0 MFR#CONTAINER
CONNECTIONSERVICE
CONNECTION
VAPOR EQUALIzING CONNECTION
CONNECTION SIzE
UL LISTED CLOSING FLOW
7556R12.0 3/4” M. NPT F. POL CGA 510 11/4” M. Acme 4200 CFH at 100 PSIG7556ZT Special/Thread Connection O-Ring
MFR#FIXED LIQUID LEVEL VENT VALVE STYLE
DIP TUBE LENGTH
FOR USE IN CONTAINERS WITH SURFACE UP TO WEBB#
7556R12.0 Knurled 12” * 162742
7556ZT — —
![Page 43: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/43.jpg)
37TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Pressure Relief Valves & Relief Valve Manifolds
37
2SECTION
2
va
lves
& a
cc
es
so
rie
s
Fully Internal “Pop-Action” Pressure Relief Valves for Transport and Delivery TrucksDesigned specifically for use as a primary relief valve in ASME transports and delivery trucks with 2” and 3” NPT couplings.
Fully Internal “Pop-Action” Pressure Relief Valves for Motor Fuel Containers8543 Series relief valves are designed for use as a primary relief valve in larger ASME motor fuel containers such as on buses, trucks and construction equipment.8544 Series relief valves are designed for use as a primary relief valve in smaller ASME and DOT motor fuel containers such as on tractors, lift trucks, cars and taxicabs.
A8434G
8544T
MFR#
START TO DISCHARGE
SETTING PSIG
CONTAINER CONNECTION
OVERALL HEIGHT
(APPROX.)
HEIGHT ABOVE
COUPLING (APPROX.)
UL ASME SUITABLE FOR TANKS WITH
SURFACE AREA UP TO*
PROTECTIVE CAP
(INCLUDED) WEBB#(AT 120% OF
SET PRESSURE)
A8434G 250 2” M. NPT 91/16” 1/2” 3700 3456 175 sq. ft. A8434-11B 187081
A8436G 250 3” M. NPT 17” 3/4” 10210 9598 602 sq. ft. A8436-11B 162575
MFR#CONTAINER
TYPE
START TO DISCHARGE
SETTING PSIG
CONTAINER CONNECTION
M. NPT
OVERALL HEIGHT
(APPROX.)
HEIGHT ABOVE
COUPLING (APPROX.)
8544GASME
2501”
57/16” 7/8”
8543G 11/4”8544T 312 1”8544K DOT/ASME 375 1”8544GT ASME 250 1”8544KT DOT/ASME 375 1”
MFR#
HEX WRENCHING
SECTION
FLOW CAPACITY SCFM/AIR***
PROTECTIVE CAP
(INCLUDED)
ACCESSORIES
WEBB#
UL ASMEPIPEAWAY ADAPTER
(AT 120% OF SET PRESSURE)
8544G 15/16” 1020 936 7544-41 7544-11A* 162757
8543G 111/16” 1465 1400 7543-40C 7543-10** 189192
8544T 15/16” 1282 1158 7544-41 7544-11A 189193
8544K 15/16” 1545*** — 7544-41 7544-11A 162758
8544GT 15/16” 1020 936 7544-41 7544-11A 273823
8544KT 15/16” 1545*** — 7544-41 7544-11A 273824
* Per NFPA Pamphlet #58, Appendix D. Area shown is for UL or ASME flow rating—whichever is larger.
T = Threadsealent*1” M.NPT outlet connection. **11/4” M.NPT outlet connection. ***Rating also applies to DOT requirements. ****Flow rates shown are for bare relief valves. Adapters and pipeaway will reduce flow as discussed in forewording information.
![Page 44: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/44.jpg)
38 victormfg.com
Pressure Relief Valves & Relief Valve Manifolds 2SECTION
Gas Equipment Catalog
Fully Internal “Pop-Action” Pressure Relief Valve for DOT Fork Lift CylindersDesigned specifically for use as a primary relief valve on forklift cylinders, the 8545AK reduces the possibility of improper functioning of the relief mechanism due to foreign material build up. All guides, springs, stem and adjusting components are located inside the cylinder — removed from the direct exposure of foreign materials and debris from the atmosphere.
8545AK With Protective Cap
MFR#CONTAINER
TYPE
START TO DISCHARGE
SETTING PSIG
CONTAINER CONNECTION
M. NPT
FLOW CAPACITY SCFM/AIR**
ACCESSORIES (ORDER SEPARATELY)
WEBB#PROTECTIVE
CAP
DEFLECTORS***(ECII® RATED AT
480 PSIG)45º
ELBOW90º
ELBOW
8545AK DOT 375 3/4” 400* 7545-40 7545-14A 7545-12 162759
* Classified by U.L. in accordance with Compressed Gas Association Pamphlet S-1.1 Pressure Device Standards for Cylinders. Meets requirements for use on DOT containers with 262 pounds or less weight of water or 109 pounds or less of LP-Gas.** Flow rates are shown for bare relief valves. Adapters and pipeaways will reduce flow as discussed in forewording information.*** Order protective cap #8545-41 or 7545-40.
Semi-Internal “Pop-Action” Pressure Relief Valve for ASME ContainersDesigned specifically for use as a primary relief valve on ASME containers such as 250, 500 and 1,000 gallon tanks. Underwriters’ Laboratories lists containers systems on which these types of valves are mounted outside the hood without additional protection, if mounted near the hood and fitted with a protective cap.
7583G
MFR#
START TO DISCHARGE
SETTING PSIG
CONTAINER CONNECTION
M. NPT
OVERALL HEIGHT
(APPROX.)
HEIGHT ABOVE
COUPLING (APPROX.)
WRENCH HEX SECTION
7583G250
3/4” 83/16” 17/16” 13/4”8684G 1” 93/8” 19/16” 17/8”8685G 11/4” 111/16” 111/16” 23/8”
MFR#
FLOW CAPACITY SCFW/AIRSUITABLE FOR
TANKS WITH SURFACE AREA
UP TO
PROTECTIVE CAP
(INCLUDED) WEBB#
UL ASME
(AT 120% OF SET PRESSURE)
7583G 1980 1806 80 sq. ft. 7583-40X 162747
8684G 2620 2565 113 sq. ft. 8684-40 162749
8685G 4385 4035 212 sq. ft. 7585-40X 162750
![Page 45: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/45.jpg)
39TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Pressure Relief Valves & Relief Valve Manifolds
39
2SECTION
2
va
lves
& a
cc
es
so
rie
s
Semi-Internal “Pop-Action” Pressure Relief Valve for Large Storage ContainersDesigned specifically for use as a primary relief valve on large stationary storage containers, these low profile relief valves are generally mounted in half couplings. However, they are designed so that the inlet ports clear the bottom of a full 2” coupling. This assures that the relief valve should always be capable of maximum flow under emergency conditions.
7534G
7534-20
7534-40
MFR#
START TO DISCHARGE
SETTING PSIGCONTAINER
CONNECTION
FLOW CAPACITY SCFM/AIR*
SUITABLE FOR TANKS WITH
SURFACE AREA UP TO**
ACCESSORIES
WEBB#
UL ASME
PROTECTIVE CAP
PIPEAWAY ADAPTER
(AT 120% OF SET PRESSURE)
7534G 250 2” M. NPT 11675 10422 708 sq. ft. 7534-40 7534-20*** 162574* Flow rates shown are for bare relief valves. Adapters and pipeaways will reduce flow as discussed in the forewording information.** Per NFPA Pamphlet #58, Appendex D. Area shown is for UL or ASME—whichever is larger.*** 3” F.NPT outlet connection.
External “Pop-Action” Supplementary Pressure Relief Valves for Small Containers and DOT CylindersDesigned for use as a supplementary relief valve on small ASME above ground and underground containers. They may also be used as a primary or secondary relief device on DOT cylinders, or as hydrostatic relief valves.All working components of these relief valves are outside the container connection, so the valves must be protected from physical damage.
MFR# CONTAINER TYPE
START TO DISCHARGE
SETTING PSIG
CONTAINER CONNECTION
M. NPTOVERALL HEIGHT
(APPROX.)WRENCH HEX
SECTION3127G
ASME 2501/4” 131/32” 7/8”
3129G 1/2” 219/32” 11/8”3127K
DOT 3751/4” 131/32” 7/8”
3129K 1/2” 219/32” 11/8”
* Flow rates shown are for bare relief valves. Adapters and pipeaways will reduce flow.
3127 Series 3127G
MFR#
FLOW CAPACITY SCFM/AIR*
SUITABLE FOR TANKS WITH
SURFACE AREA UP TO*
ACCESSORIES
WEBB#
UL ASME
PROTECTIVE CAP
PIPEAWAY ADAPTER
(AT 120% OF SET PRESSURE) MFR#OUTLET
SIzE
3127G 295 — —
7545-40
— 162420
3129G 465 3129-10 1/2” F. NPT 162429
3127K—
450 100 lbs./Propane — 162424
3129K 780 200 lbs./Propane 3129-10 1/2” F. NPT —
![Page 46: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/46.jpg)
40 victormfg.com
Pressure Relief Valves & Relief Valve Manifolds 2SECTION
Gas Equipment Catalog
MFR#
START TO DISCHARGE
SETTING PSIG
CONTAINER CONNECTION
M. NPT
OVERALL HEIGHT
(APPROX.)
WRENCH HEX
SECTION
FLOW CAPACITY SCFW/AIR (A)UL ASME
(AT 120% OF SET PRESSURE)
AA3126L030 301/2” 2” —
(b) —AA3126L250
250
277 (c) —3131G
3/4” 37/16” 13/4”2060 1939
AA3130UA250 2045 1838W3132G 1”
61/32” 2”3340
—3132G
11/4”
4130MV3132G 39953135G 521/32”
211/16”5770 —
AA3135UA250 613/32” 6430 5080 (d)3133G 11/2” 515/16” 31/8” 6080 —A3149G 21/2” 101/2” 41/8” 10390 9153AA3130UA265 265 3/4” 37/16” 103/4” 2125 1912
MFR#
SUITABLE FOR TANKS
WITH SURFACE AREA UP
TO (E)
ACCESSORIES
WEBB#PROTECTIVE
CAP
PIPEAWAY ADAPTER
WEEP HOLE DEFLECTORMFR#
OUTLET SIzE
AA3126L030 —7545-40 AA3126-10 1/2” M. NPT
—
187092
AA3126L250 23 sq. ft. (f) 187093
3131G 85 sq. ft. 3131-40 (g) — 162436
AA3130UA250 249 sq. ft. (f) AA3130-40P AA3131-10 1” F. NPT 187095
W3132G 154 sq. ft.
3132-54 (g)
3132-10 11/4” F. NPT
3133-11
162444
3132G 200 sq. ft.—
162442
MV3132G 190 sq. ft. 188588
3135G 300 sq. ft. 3135-54 (g) 3135-10
2” F. NPT
162447
AA3135UA250 1010 sq. ft. (f) AA3135-40PR AA3135-10 190683
3133G 320 sq. ft. 3133-40 (g) — 162446
A3149G 613 sq. ft. 3149-40 (h) Included (j) 162572
AA3130UA265 261 sq. ft. (f) AA3130-40P AA3131-10 1” F. NPT — 189239
(b) Not UL or ASME rated. .059 sq. in. effective area.(c) Not UL or ASME rated. ECII® rated at 120% of set pressure.(d) Rated at 110% of set pressure.(f ) Per ANSI K61.1-1972. Appendix A(g) Cap supplied with chain.(h) Outlet 31/2-8N (F) thread, will accept 3” M. NPT pipe thread.( j) Weep hole deflector is Part No. A3134-11B.
External “Pop-Action” Pressure Relief Valve for ASME Containers and Bulk Plant InstallationsDesigned for use as a primary relief valve on ASME above ground and underground containers, bulk plant installations and skid tanks. The 3131 Series may also be used as a primary or secondary relief valve on DOT cylinders, or as a hydrostatic relief valve.All working components of these relief valves are outside the container connection, so the valves must be protected from physical damage.
AA3135
3135
3135-10
![Page 47: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/47.jpg)
41TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Pressure Relief Valves & Relief Valve Manifolds
41
2SECTION
2
va
lves
& a
cc
es
so
rie
s
3127G SS8022G
External Hydrostatic Relief ValvesDesigned especially for protection of piping and shut-off valves where there is a possibility of trapping liquid LP-Gas or anhydrous ammonia. They may be installed in pipelines and hoses located between shut-off valves or in the side of boss in RegO® shut-off valves.
MFR#
START TO DISCHARGE
SETTING PSIG
VALVE BODY
MATERIAL
CONTAINER CONNECTION
M. NPTHEIGHT
(APPROX.)
WRENCH HEX
SECTION
ACCESSORIES
WEBB#
PROTECTIVE CAP
(INCLUDED)
PIPEAWAYADAPTER OR
THREADS
SS8001G
250
Stainless Steel
1/4”—
11/16”
—
—283973
SS8002G 1/2” — 189248
SS8021G 1/4”1”
11/16” 1/4” NPSM Thrds 162494
SS8022G 1/2”—
3/8” NPT Thrds 189249
3127G
Brass
1/4” 131/32”
7545-40
— 162420
3129G 1/2” 219/32” 1” 3129-10 162429
3127H275
1/4” 131/32” 7/8” — 162422
3129H 1/2” 219/32” 11/8” 3129-10 186844
3127P300
1/4” 131/32” 7/8” — 186843
3129P 1/2” 219/32” 11/8” 3129-10 —
3127J
350
1/4” 131/32” 7/8” — 162423
3129J 1/2” 219/32” 11/8” 3129-10 162430
SS8001JStainless
Steel
1/4” — 11/16”
—
— 187114
SS8021J 1/4”1”
11/16” 1/4” NPSM Thrds 193305
SS8022J 1/2”7/8”
3/8” NPT Thrds 187116
3127K375
Brass
1/4” 131/32”7545-40
— 162424
3129K 1/2” 219/32” 11/8” 3129-10 —
3125L
400
1/4”19/16” 5/8” 3125-40P
—162751
3127L 131/32” 7/8” 7545-40 162426
3129L 1/2” 219/32” 11/8” 3129-40P 3129-10 —
SS8001LStainless
Steel
1/4” 7/8” 11/16”
—
— —
SS8021L 1/4”13/8”
11/16” 1/4” NPSM Thrds 162495
SS8022L 1/2”—
3/8” NPT Thrds —
3127U
450
Brass1/4” 131/32”
7545-40— 162428
3129U 1/2” 219/32” 1” 3129-10 162432
SS8001U
Stainless Steel
1/4”—
11/16”
—
—162490
SS8002U 1/2” — —
SS8021U 1/4”1”
11/16” 1/4” NPSM Thrds 162496
SS8022U 1/2” — 3/8” NPT Thrds 189250
![Page 48: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/48.jpg)
42 victormfg.com
Pressure Relief Valves & Relief Valve Manifolds 2SECTION
Gas Equipment Catalog
DuoPort® Pressure Relief Valve Manifoldsfor Small Storage ContainersDesigned especially for use as a primary relief device on smaller stationary storage containers, with 2” NPT threaded couplings. These manifolds allow servicing or replacement of either of the two relief valves without evacuating the container or loss of service. The operating lever selectively closes off the entrance port to the relief valve being removed while the remaining valve provides protection for the container and its contents. The rating of each manifold is based on actual flow through the manifold and a single pressure relief valve, taking friction loss into account, it is not merely the rating of the relief valve alone.
Multiport® Pressure Relief Valve Assemblies for Large Storage ContainersDesigned especially for use as a primary relief device on large stationary pressurized storage containers with flanged openings. These manifolds incorporate an additional relief valve, not included in the flow rating, allowing for servicing or replacement of any one of the relief valves without evacuating the container. The handwheel on the manifold selectively closes off the entrance port to the relief valve being removed while the remaining relief valves provide protection for the container and its contents. All manifold flow ratings are based on flow through the relief valves after one has been removed for service or replacement.
AA8542UA250
A8564G
MFR#
START DISCHARGE
SETTING PSIG
APPLICATIONCONTAINER CONNECTION
M. NPTLP-GAS NH3
8542G 250 Yes No 2”AA8542UA250 250 No Yes 2”
MFR#
START DISCHARGE
SETTING PSIG
APPLICATIONCONTAINER FLANGE
CONNECTIONLP-GAS NH3
A8564G
250 Yes Yes
3” - 300#A8574G 4” - 300#A8564AG 3” - 300#A8574AG 4” - 300#
MFR#
RELIEF VALVE INCLUDEDFLOW CAPACITY SCFM/AIR** (AT 120% OF SET PRESSURE)
WEBB#QUANTITY MFR#
INLET CONNECTION
M. NPT
ACCESSORY
UL RATING ASME RATINGPIPEAWAY ADAPTORS
8542G 2 3135MG 11/4” 3135-10* 5250 (1) NA 189191
AA8542UA250 — — — — — — 189245
MFR#
RELIEF VALVE INCLUDEDFLOW CAPACITY SCFM/AIR (AT 120% OF SET PRESSURE)
WEBB#QUANTITY
MFR#
INLET CONNECTION
M. NPT
ACCESSORY
UL RATING ASME RATINGPIPEAWAY ADAPTORS
A8564G
4
A3149MG
21/2” Outlet 31/2-*N (F) thread, will accept 3” M. NPT pipe thread.
27,750 (3) N/A162576
A8574G 162577
A8564AGA3149G Not Applicable 27,400
251121
A8574AG 251122
* 2” F. NPT outlet connection.** Flow rating based on number of relief valves indicated in parenthesis ( ). Flow rates shown are for bare relief valves. Adapters and pipeaways will reduce flow rates as discussed in forewording information.
![Page 49: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/49.jpg)
43TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Pressure Relief Valves & Relief Valve Manifolds
43
2SECTION
2
va
lves
& a
cc
es
so
rie
s
Multiport® Pressure Relief Valve Assemblies for Large Storage Containers (continued)
Flanged Internal Valves Mounting Information
Flange Dimensions
MANIFOLD SIzES FLANGE SIzE FLANGE DRILLING
PORT DIAMETER FLANGE GASKET
A8560 Modified 3” 300# (4” Port Dia.)
(8) 7/8” Bolt Holes on a 65/8” Bolt Circle Diameter
Flat Faced.4” 3”
7564-48
A8570AA8570
4” ASA300#
(8) 7/8” Bolt Holes on a 77/8” Bolt Circle Diameter
1/16” Raised Face.4” 4”
7565-48
MFR# CONSISTS OF FOR USE WITHFOR
CONNECTION TONUMBER
REQUIRED WEBB#
7560-55 1-Bolt Stud and Nut
All RegO MultiportsTM
Modified 3” - 300#and 4” - ASA 300#
Welding Neck Flange 8186924
7560-56 Manhold Cover Plate 189178
MFR# DESCRIPTION WEBB#
7560-55 1 Nut and Stud 186924
7560-56 2 Nuts and Stud 189178
7560-58 3.50 Length —
7560-60 1.13 Hex.64 Thk —
GasketMFR# DESCRIPTION WEBB#
7565-487.00 O.D.5.00 I.D.0.13 Thk
273810
7884-307.00 O.D.5.82 I.D.0.18 Thk
186948
A7883-295.75 O.D.4.75 I.D.0.18 Thk
187055
A7883-308.75 O.D.4.00 I.D.0.13 Thk
187057
Victor/F.w. Webb has a “Trade-in” program for multiport pressure relief valves.
![Page 50: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/50.jpg)
44 victormfg.com
Globe & Angle Valves 2SECTION
Gas Equipment Catalog
“V”–Ring Seal Globe and Angle Valves for Bulk Storage Containers, Transports, Bobtails and Plant PipingSpecifically designed to assure positive shut-off and long, maintenance-free service life in liquid or vapor service on bulk storage containers, transports, bobtails, cylinder filling plants and plant piping.The high quality construction and wide variety of sizes make them highly suited for use with LP-Gas, anhydrous ammonia and in the chemical and petrochemical industries.
TA7034
A7505AP
A7513AP
A7517FP A7517AP A7518FP
MFR# WEBB#
TA7034P —
TA7034LP 189253
A7505AP 162539
A7506AP 162540
TA7505AP 187120
TA7506AP —
A7507AP 162541
A7508AP 162542
TA7507AP 192877
A7509BP 162543
A7510BP 162544
TA7509BP 193216
TA7510BP —
A7511AP 162545
A7512AP 162546
TA7511AP 273830
TA7512AP —
A7511FP —
A7513AP 162547
A7514AP 162548
TA7513AP 190681
A7513FP 188570
A7514FP 162549
TA7513FP 187124
A7517AP 162550
A7518AP 162551
TA7517AP 187126
TA7518AP —
A7517FP 187041
A7518FP 162552
TA7517FP 189255
MFR#
INLET & OUTLET
CONNECTIONPORT
DIAMETER
FLOW AT 1 PSIG
PRESSURE DROP (CV)
(GPM/PROPANE)*** ACCESSORIES
BUNA N SEAT DISCS
TEFLON SEAT DISCS*
GLOBE ANGLE GLOBE ANGLE GLOBE ANGLE
HYDRO-STATIC RELIEF VALVE
VENT VALVE
— — TA7034P TA7034LP 1/2” F. NPT3/4”
10.00 14.8
SS8001U#162490
TSS3169#162450
A7505AP A7506AP TA7505AP TA7506AP 3/4” F. NPT 12.0 17.7A7507AP A7508AP TA7507AP — 1” F. NPT 1” 17.8 22.0A7509BP A7510BP TA7509BP TA7510BP 11/4” F. NPT 11/4” 36.5 54.0A7511AP A7512AP TA7511AP TA7512AP 11/2” F. NPT
11/2”43.0 55.5
A7511FP — ——
11/2” Flange** 46.0 —A7513AP A7514AP TA7513AP 2” F. NPT
2”75.0 88.5
A7513FP A7514FP TA7513FP TA7614FP 2” Flange** 78.0 133.0A7517AP A7518AP TA7517AP TA7518AP 3” F. NPT
3” 197.0 303.0A7517FP A7518FP TA7517FP — 3” Flange**
* Teflon seat discs on valves built to order.** 300# ANSI R.F. Flange*** To obtain approximate flow at other than 1 PSIG pressure drop, multiply flow in chart by square root of pressure drop.
Reducing screwed flanges are available for reducing 11/2” flange or 1” or 11/2” pipe thread and 3” flanged to 21/2” pipe thread. Order from your local supplier.
Flange DimensionsVALVE NUMBER SIzE FLANGE DRILLING D E F H
7511FP 11/2” 7/8” Bolt Holes on a 41/2” Bolt Circle Diameter 61/8” 13/16” 27/8” 3/4”
7513FP2” 3/4” Bolt Holes on a
5” Bolt Circle Diameter 61/2” 7/8” 35/8” 13/16”7514FP
7517FP 3” 7/8” Bolt Holes on a 65/8” Bolt Circle Diameter 81/4” 11/8” 5” 11/16”
7518FP — — — — — —
![Page 51: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/51.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Globe & Angle Valves
45
2SECTION
2
va
lves
& a
cc
es
so
rie
s
Quick-Acting Minimum Loss Hose-End Valves for Bobtail Delivery Trucks and Dispensing StationsDesigned to vastly reduce the amount of product vented when disconnecting bobtail trucks, dispensing systems and anhydrous ammonia nurse tanks.These valves provide instant, full-on-flow at the flip of a handle. Shut-off is instant and the handle locks for added protection.This “top of the line” hose-end valve is a fully contained unit that does not require additional filling adapters or connectors.
Quick-Acting Hose-End Valves for Bobtail Delivery Trucks and Dispensing StationsDesigned especially for safe operator handling of LP-Gas in bobtail delivery truck, dispensing systems and anhydrous ammonia nurse tank service.These valves provide instant, full-on flow at the flip of the handle and provide instant positive shut-off with a handle lock for added protection.
Flange Seal Globe and Angle Valves for Bulk Storage Containers, Filling Hoses and Plant PipingDesigned to assure positive shut-off and long maintenance-free service life in liquid or vapor service. Ideally suited for use on cylinder charging manifolds, truck filling hoses, bulk storage containers and plant piping.The high quality construction and wide variety of sizes make them highly suited for use with LP-Gas, anhydrous ammonia and in the chemical and petrochemical industries.
A7707L
A7704P
A7797AMFR#
INLET CONNECTION
F. NPT
OUTLET CONNECTION
F. ACMELOCKING HANDLE
FLOW AT 1 PSIG (CV)
PRESSURE DROP (GPM/PROPANE) WEBB#
A7793A 3/4” 13/4” Yes 16.0 187049
A7797A 1” 13/4” Yes 16.0 162563
MFR#BODY
DESIGN
INLET & OUTLET
CONNECTIONF. NPT
FLOW AT 1 PSIG (CV)
PRESSURE DROP (GPM/PROPANE)
ACCESSORIES
WEBB#HYDROSTATIC RELIEF VALVE
VENTVALVE
7704P Globe
1/2”
7.3
SS8001J or SS8001L TSS3169
162557
7704LP Angle 12.3 190689
A7704P Globe 7.3 162558
A7704LP Angle 12.3 162559
MFR#BODY
DESIGN
INLET & OUTLET
CONNECTIONLOCKING HANDLE
FLOW AT 1 PSIG (CV)
PRESSURE DROP (GPM/PROPANE)
ACCESSORIES
WEBB#
FILLING CONNECTORSEXTENDED COMPACT
STEEL BRASS STEEL
A7707L Globe1” Yes
18.0 A7575L4#162711
3175A#162688
A3175A#162689
187048
A7708L Angle 22.0 162562
![Page 52: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/52.jpg)
46 victormfg.com
Globe & Angle Valves 2SECTION
Gas Equipment Catalog
Flange Seal Globe and Angle Valves for Bulk Storage Containers, Filling Hoses and Plant Piping (continued)
MFR#BODY
DESIGN
INLET & OUTLET
CONNECTIONF.NPT
FLOW AT 1 PSIG (CV)
PRESSURE DROP (GPM/PROPANE)
ACCESSORIES
WEBB#HYDROSTATIC RELIEF VALVE
VENTVALVE
7705P Globe
3/4”
11.5
SS8001J or SS8001L TSS3169
163076
7706P Angle 17.7 163077
A7705P Globe 11.5 162560
A7706P Angle 17.7 162561
Flange Seal Liquid Transfer Angle Valves for Bulk Storage ContainersDesigned especially for liquid transfer of LP-Gas from consumer bulk storage containers when used with a Chek-Lok® or equipped with an integral excess flow valve. May also be used for vapor LP-Gas service.In NH3 applicator tanks they may be used as a vapor bleeder valve or as a liquid withdrawal valve when installed in a coupling with a dip pipe.These liquid transfer valves are equipped with an integral excess flow valve for liquid transfer directly from the tank fitting, or without an integral excess flow for LP Gas transfer through a Check-Lok®.When equipped with an integral excess flow valve (7550PX), the valve should be mounted in a forged steel 3000 lb. half coupling. When mounted in a 11/4” X 3/4” NPT reducing coupling, the 3/4” female thread in this coupling must be full length — equivalent to a forged steel 3000 lb. half coupling.The excess flow valve will not function properly if these specifications are not met.
7550P
MFR#
INLET & OUTLET
CONNECTIONM. NPT
OUTLET CONNECTION
F. NPT
INTEGRAL EXCESS
FLOW
FLOW AT 1 PSIG (CV) PRESSURE
DROP (GPM/PROPANE)
EXCESS FLOW APPROXIMATE CLOSING FLOW (GPM/PROPANE)
ACCESSORIES
WEBB#
HYDRO-STATIC RELIEF VALVE
VENT VALVE
7550P
3/4”
3/4”
No 13.3 —3127U 3165 162760
A7550P SS8001J TSS3169 162474
7550PXYes — 16.0
3127U 3165 162476
A7550PX SS8001J TSS3169 162475
7551P1/2” No 8.9 —
3127U 3165 266448
A7551P SS8001J TSS3169 273806
A7706P
![Page 53: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/53.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Globe & Angle Valves
47
2SECTION
2
va
lves
& a
cc
es
so
rie
s
Quick-Acting Valves for Cylinder Charging HosesDesigned primarily for use on cylinder charging hoses to provide fast, convenient shut-off and fast opening.These valves must be installed so that flow through the valve is in the opposite direction to that of a conventional globe valve. This allows the inlet flow to assist in closing the valve, even more important, helps prevent the valve from being forced open by high pump pressure.
7901TAMFR#
INLET CONNECTION
F. NPT
OUTLET CONNECTION
F. NPTBODY
MATERIAL
FLOW AT 1 PSIG (CV)
PRESSURE DROP (GPM/PROPANE) WEBB#
A7553A 1/4” 1/4” Ductile Iron
1.95
189220
7901TA 3/8” 3/8”
Brass
162487
7901TB1/2”
1/4” 162488
7901TC 1/2” 162489
Quick-Acting Valves for Crop Driers and Charging Manifold Hoses7554S Series valves provide instant shut-off and fast opening control on LP-Gas crop driers. They are ideal for charging manifold hoses, stationary fuel transfer hoses and other applications requiring quick, positive shut-off. They are not for use with delivery truck hoses because the handle could snag on the ground and open the valve as the hose is needed back to the truck7554L Series valves feature a locking handle device to help prevent accidental opening of the valve. It is ideal for all the same applications as the 7554S Series and may be used on delivery trucks as it incorporates the locking handle design.Both valve series must be installed so that flow through the valve is opposite to that of a conventional globe valve. This allows the inlet flow to assist in closing the valve and prevents the valve from being opened by high pump pressures.
7554S
MFR#
INLET & OUTLETCONNECTION
F. NPTLOCKING HANDLE
FLOW AT 1 PSIG (CV) PRESSURE DROP (GPM/PROPANE) WEBB#
7554SAV1/2”
No7.3
186921
7554LAV Yes 186920
7554SV3/4”
No11.5
162555
7554LV Yes 162553
![Page 54: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/54.jpg)
48 victormfg.com
Globe & Angle Valves 2SECTION
Gas Equipment Catalog
Multipurpose Valves for Liquid Withdrawal of LP-Gas and NH3 ContainersDesigned especially for use as a high capacity liquid withdrawal valve on LP-Gas and anhydrous ammonia containers.The A8017DH is equipped with a soft seated automatic differential back pressure check valve in the seat disc assembly. This allows any pressure build up in the liquid transfer line in excess of 10-15 psig above the container pressure to flow back into the container. The transfer hose is protected against excessive liquid or vapor pressure entrapment, which adds materially to the useful life of flexible hose. In addition to increasing hose service life, the equalizing valve adds substantially to the operating safety of liquid transfer systems.
Multipurpose Valve for Filling and Liquid Transfer of NH3 ContainersDesigned primarily for use as a combination filler and liquid withdrawal valve on three-opening applicator tanks or on nurse tanks.This valve incorporates an integral excess flow valve. When product is required, the valve must be completely open and backseated to allow the excess flow valve to function properly.
A8017DP
A8018DP
MFR#
INLET CONNECTION
M. NPT
OUTLET CONNECTION
F. NPT
EXCESS FLOW APPROXIMATE CLOSING FLOW (GPM/PROPANE)
ACCESSORIES
WEBB#
HYDRO-STATIC RELIEF VALVE
VENT VALVE
A8017DH
11/4” 1”
49 Not Required TSS3169
187075
A8017DP 55 SS8001J 162493
A8017DLP — — — 190679
MFR#
INLET CONNECTION
M. NPT
OUTLET CONNECTION
F. NPT
FILLING CONNECTION
M. ACME
FILLING CAPACITY AT 20 PSIG PRESSURE DROP GPM/
NH3
EXCESS FLOW APPROXIMATE CLOSING FLOW
(GPM/NH3)
ACCESSORIES
WEBB#
HYDRO-STATIC RELIEF VALVE
VENT VALVE
A8018DP 11/4” 1” 13/4” 74 50 SS8001J TSS3169 187076
![Page 55: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/55.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Ball Valves
49
2SECTION
2
va
lves
& a
cc
es
so
rie
s
MFR# DESC. WEBB#JOM100-297 1/8” F X M 111346JOM100-299 1/4” F X M 111348JOM100-300 1/4” F X F 151225
For use on LP-Gas, flammable liquids, natural and mfg. gas, air, N2, inert gases, including helium and CO2.
MFR# DESC. WEBB#Model T-100 SeriesJOM100-701 1/4” F. IPS 184932JOM100-702 3/8” F. IPS 184933JOM100-703 1/2” F. IPS 151448JOM100-704 3/4” F. IPS 151449JOM100-705 1” F. IPS 163961JOM100-706 11/4” F. IPS 151450JOM100-707 11/2” F. IPS 151451JOM100-708 2” F. IPS 163962JOM100-709 21/2” F. IPS —JOM100-710 3” F. IPS 151453Model S-100 Series JOM100-803 1/2” C X C 151454JOM100-804 3/4” C X C 151455JOM100-805 1” C X C 151456JOM100-806 11/4” C X C 151457JOM100-807 11/2” C X C 151458JOM100-808 2” C X C 151459JOM100-809 21/2” C X C —
• 1/4” – 2” • Operable from -40°F to 300°F• UL listed
Model T/S-100
MFR# DESC. WEBB#Model T-204 – FIP X FL JOM101-502 1/2” X 3/8” FIP X FL 165040JOM101-503 1/2” FIP X FL 58791Model T-204 – FL X FL JOM101-601 1/2” X 3/8” FL X FL 178937JOM101-602 3/8” FL X FL 184941JOM101-603 1/2” FL X FL 184942JOM101-604 5/8” FL X FL 184940Model T-204 – MIP X FL JOM101-702 1/2” X 3/8” MIP X FL 164856JOM101-703 1/2” MIP X FL 164857
MFR# DESC. WEBB#Model T-204 – FIP X FIP JOM101-401 1/4” FIP X FIP 184937JOM101-402 3/8” FIP X FIP 184938JOM101-403 1/2” FIP X FIP 184939JOM101-404 3/4” FIP X FIP 184935
Models T-204 The new Jomar System-2 FIP to Flare, Flare to Flare and MIP to Flare valves are new products with vision. Equipped with all the features of the Blue-Cap®.• Raised wrench flats for installation ease.• It can be used in temperatures from -40°F to 300°F,
making it ideal for outside use in extremely cold or warm climates.
• The T-handle can be reversed into a locked position, by turning the handle to the off position, removing the tamper proof alien screw and reversing the handle 180° into the slot.
• Each valve is shipped with plastic thread protectors to prevent leak causing nicks.
• AGA and CGA design certified for use with natural, manufactured, mixed, liquified petroleum and LP gas/ air mixture.
• AGA and CGA listed 0.5, 2 lb., 5 lb., System.
Model T-204Jomar’s Blue Cap® II Manual Gas Valve, Model T-204 is American Gas Association Laboratories design certified for use with natural, manufactured, mixed, liquified petroleum and LP gas/air mixtures. The Blue Cap® II may be used as a 150lb. steam valve/600 W.O.G.
MFR# DESC. WEBB#JOM100-953 1/2” SS 184958JOM100-954 3/4” SS 184951JOM100-955 1” SS 184955JOM100-956 11/4” SS 184956JOM100-958 2” SS 184957
T-CS-2000 SeriesJomar’s T-2000 Series of steel valves are designed for rugged industrial applications of steam, water, oil, gas and corrosive materials. They are UL approved for LP-Gas, natural and manufactured gas, LP gas/air mixtures and anhydrous-ammonia. They feature solid ball construction, reinforced P.T.F.E. seats, two piece standard port design. Double viton o-rings prevent stem leakage. Special 2000 psi seats available upon request.
Locking Device 100-82-3LD Series• Type 2: Fits models T/S100, T-100UE, T/S100ST, T-100FB, T-100C and T-100SS, Size 3/4”.• Type 3: Fits models T/S100, T-100UE, T/S100ST, T-100FB, T-100C and T-100SS, Sizes 1” and 11/4”.
MFR# DESC. WEBB#JOM210-995 3/4” Locking Device 111377JOM210-996 1 – 11/4” Locking Device —
Models T-82 – Mini ValvesAre designed for steam, water, oil or gas in commercial and light industrial use. The minivalves are competitive, conventional port, constructed of heavy duty forged brass, 100% Teflon seats and gland follower with double viton o-rings, to prevent stem leakage. Sells and installs cost wise as the leaky plug type, pet cock or gage cock without the leaks.
Gas Ball Valves
![Page 56: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/56.jpg)
50 victormfg.com
Ball Valves 2SECTION
Gas Equipment Catalog
Model T-203 Equipped with all the features of the Blue-Cap®, the System-3 has additional features making it the best value on the valve market today.• A 1/8” NPT side tap allows a manometer to be inserted
into the valve to test line pressure, eliminating the test tee and the labor to install it.
• It can be used in temperatures down to -40°F to 300°F, making it ideal for outside use in extremely cold or warm climates.
• The handle can be reversed into a locked position. Combined with the tamper proof screw, the possibility of unauthorized use is sharply reduced.
• AGA and CGA design certified for use with natural, manufactured, mixed, liquified petroleum and LP gas/ air mixture.
• UL Listings: LP-Gas, flammable liquids, natural and manufactured gas, air, N2, inert gases including helium and CO2.
• The valve is rated 150 WSP/600 WOG. Remove the plug and you have a drainable ball valve for any fluid system.
Gas Ball Valves (continued) T-2000N Series Carbon Steel
Jomar’s T-2000N Series of steel valves are designed for rugged industrial applications of steam, water, oil, gas and corrosive materials. They are UL approved for LP-Gas, natural and manufactured gas, LP-Gas air mixtures and anhydrous–ammonia. They feature solid ball construction, 2nd generation P.T.F.E. seats, two piece standard port design. Double Viton O-Rings prevent stem leakage. Special 2000 PSI seats available upon request.• Conforms to federal specification WW-V-35.• Latch-Lock Feature: Valve comes complete with latch
lock, which may be locked in open or closed position.• Pressure Rating: 2000 W.O.G.
MFR# DESC. WEBB#Model T-CS-2000N-SS JOM100-953 1/2” 184958JOM100-954 3/4” 184951JOM100-955 1” 184955JOM100-956 11/4” 184956JOM100-958 2” 184957
Dimension in Inches
SIzE A B C D CV*1/4” 2.07 0.37 1.76 4.33 6.83/8” 2.07 0.37 1.76 4.33 6.81/2” 2.34 0.50 1.92 4.33 9.83/4” 2.80 0.69 2.40 5.83 251” 3.23 0.87 2.56 5.83 3511/4” 3.57 1.00 2.74 7.76 4711/2” 4.04 1.25 2.98 7.76 812” 4.63 1.50 3.17 7.76 105
* The CV Factor is the gallons of water per minute passed through the valve with 1 PSI pressure drop.
MFR# DESC. WEBB#Model T-203 – FIP X FIP JOM102-301 1/4” FEM Side Tap 178938JOM102-302 3/8” FEM Side Tap 151303JOM102-303 1/2” FEM Side Tap 151304JOM102-304 3/4” FEM Side Tap 151305JOM170-105 1” FEM Side Tap 178939Model T-203 – FL X FL JOM102-402 3/8” FL Side Tap 151306JOM102-403 1/2” FL Side Tap 151307JOM102-404 5/8” FL Side Tap 151308JOM102-405 1/2” FEM X FL Side Tap 167285
![Page 57: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/57.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Ball Valves
51
2SECTION
2
va
lves
& a
cc
es
so
rie
s
Lockable Valve for Meter
• Special design.• Hot forged brass.• Pure Teflon® seats.• -40°F +350°F temperature.• Approved by AGA & CGA to ASME. B16.33 & AGA Req’t #3-88.• Full port to DIN 3357 for maximum flow.• Double seal system allows valve to be operated in either
direction making installation easier.• Two Viton 0-rings at the stem for maximum safety.• No maintenance ever required.• 600 PSI non-shock cold working pressure.
MFR# DESCRIPTION WEBB#S80E41 3/4” Lockable Valve 250084S80F41 1” Lockable Valve 250085S80G41 11/4” Lockable Valve 378023S80H41 11/2” Lockable Valve 378025S80I41 2” Lockable Valve 378026
CODE S80E41 S800F41D 3/4” 1”L 2.519 3.188H 1.801 1.958
With tamper proof locking cover.s.80 NPT — 3/4” & 1”
MFR# SIzE WEBB#70 Series With Tee-Handle APO7010307 1/2” 54031APO7010407 3/4” 54032APO7010507 1” 54033APO7010607 11/4” 359APO7010707 11/2” 360APO7010807 2” 361
MFR# SIzE WEBB#80 Series Lever Handle – UL Listed for Propane APO80103 1/2” 55189APO80104 3/4” 55190APO80105 1” 55191APO80106 11/4” 55192APO80107 11/2” 55193APO80108 2” 55194
Apollo Valves
Rub Brass Locking Gas Shutoffs
MFR# DESCRIPTION WEBB#VCTS80E41 3/4” 250084VCTS80F41 1” 250085VCTS80G41 11/4” 378023VCTS80H41 11/2” 378025VCTS80I41 2” 378026
8043 Series
MFR# DESCRIPTION WEBB#VCTS80E43 3/4” With Union 378021VCTS80F43 1” With Union 378022VCTS80G43 11/4” With Union 378024
Made In The USA
80 Series
![Page 58: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/58.jpg)
52 victormfg.com
Ball Valves 2SECTION
Gas Equipment Catalog
• Gases: Natural or LP-Gases.• Service Designation: 175 PSIG.• Options: Test Tap at inlet, brass or painted finish.• 100% Leakage Testing: at 1.5 times service designation
(263 PSIG); test methods meet or exceed D.O.T and ANSI B16.33.
• ISO-EN 9002: Certified.• Threads Conform: To ANSI B1.20.1.• Warranty: 10 years against leakage under normal
operating conditions.
Chicago FaucetsChicago Faucets multiple service valves enable the user to access virtually any laboratory gas. Solid brass construction with a high-gloss polished chrome finish and color coded handle index buttons.• Ball valve.• E7 – Removable serrated hose nozzle.• Air, gas and vacuum buttons.• 3/8” NPT male inlet thread.• 124 PSI or approximately 29.9” Hg vacuum.
MFR# DESC. WEBB#Laboratory Gas Valve CFC909AGVCP 3/4” NPT Inlet 117590
760B 6276B
560B Black Iron Body3/4”, 1”, 11/4”, 11/2”, 2”
560B Black Iron Body 1/2”, 3/4”, 1”, 11/4”
MFR# DESC. WEBB#AYM560B-8 1/2” 184925
MFR# DESC. WEBB#AYM560B-34 3/4” 184924
MFR# DESC. WEBB#AYM6276B-34 3/4” 216737AYM6276B-1 1” 216738AYM6276B-114 11/4” 216739
Special Order
High Pressure Meter Valves — Plug Style
High Pressure Meter Valves — Ball Style
Tamperproof • 175 PSIG Flat Head • lockwing
Tamperproof • 175 PSIG • PatentedFlat Head • lockwing
Model 175 LWiN
MFR# DESC. WEBB#Brass Locking Meter Valve With Union JOM241-004B 3/4” 276314JOM241-005B 1” —
Pressure Tap Optional
Safe Ball®
The Gas Stops Here!Model 175 LWN & Model 175 LWIN
Model 175 LWN
![Page 59: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/59.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Excess Flow, Check, Filler, Vapor Equalizing Valves
53
2SECTION
2
va
lves
& a
cc
es
so
rie
s
Excess Flow Valves for Liquid or Vapor Line ServiceDesigned for top installation, in any position, in liquid or vapor service lines. They are intended for long lines or branch piping where tank mounted excess flow valves cannot suffice.
Excess Flow Valves for Liquid or Vapor Designed for liquid or vapor use for filling, withdrawal and vapor equalizing in container or line applications. They are intended for long lines or branch piping where tank-mounted excess flow valves are inadequate.
A1519A6
3282C
MFR# BODYMATERIAL
INLETCONNECTION
NPT
OUTLETCONNECTION
F. NPT
WRENCH HEX
FLATS
APPROXIMATE CLOSING FLOWS
WEBB#LIQUID (GPM
PROPANE)
VAPOR SCHF (PROPANE)25 PSIG INLET
100 PSIGINLET
1519A2 Brass1” 1” 13/4” 25 5,000 8,800 162410
A1519A2 Steel 2738051519A3
Brass11/2” 11/2” 21/4” 60 11,500 20,200 275127
1519A4 2” 2” 3” 100 19,000 34,500 189125A1519A6 Steel 3” 3” 4” 225 45,000 82,000 —
MFR# BODYMATERIAL
AINLET
CONNECTIONNPT
BOUTLET
CONNECTIONF. NPT
CWRENCH
HEXFLATS
DEFFECTIVE
LENGTH(APPROX.)
APPROXIMATE CLOSING FLOWS*
WEBB#
LIQUID (GPM
PROPANE)
VAPOR SCHF (PROPANE)25
PSIG INLET
100 PSIGINLET
12472
Brass3/4” 3/4” 1” 1”
4 1,050 1,700 1868033272E 10 2,100 3,700 1624523272F 15 2,800 5,000 1624533272G
20 3,700 6,900 162584A3272G Steel 1625853282A
Brass11/4” 11/4” 2” 115/16”
30 5,850 10,000 1625863282C
50 9,000 16,300 186857A3282C Steel 1625877574
Brass11/2” 11/2” 21/4” 13/4” 90 15,200 28,100 162480
3292A
2” 2” 2” 1”
75 14,200 24,800 189148A3292A Steel —3292B Brass
100 18,100 32,700 162588A3292B
Steel 162589A3292C 122 22,100 37,600 162590
* Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down.NOTE: Multiply flow rate by .94 to determine liquid butane flow and by .90 to determine liquid anhydrous ammonia flow.
![Page 60: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/60.jpg)
54 victormfg.com
Excess Flow, Check, Filler, Vapor Equalizing Valves 2SECTION
Gas Equipment Catalog
Excess Flow Valves for Container ServiceDesigned for mounting in threaded full or half couplings in container installations. They may be used for filling, withdrawal or vapor equalizing applications. The exceptionally low pressure drop makes them ideal for pump suction lines. If a riser pipe to the vapor space is used with these valves, the minimum inside diameter of the riser must be at least two times the valve thread size in order not to restrict flow to the side inlet ports.
A7537N4F
Excess Flow Valves for Liquid or Vapor ServiceDesigned for top mounting in storage tank manhole covers for liquid or vapor applications. The tapped inlet allows for an optional 1” NPT dip pipe connection to withdraw liquid from the top of the tank.The 1519C4 is designed for installation in long line or branch piping applications.
1519C4
MFR#INLET
CONNECTIONNPT
FILLINGCONNECTION
F. NPTWRENCH
HEX FLATS
APPROXIMATE CLOSING FLOWS
WEBB#
LIQUID (GPM PROPANE)
VAPOR SCHF (PROPANE)25 PSIG INLET
100 PSIGINLET
1519C4 2” Female 2” 3” 170 28,590 48,600 162411NOTE: Multiply flow rate by .94 to determine liquid butane flow.
MFR#FOR USE
WITHTHIS TYPECOUPLING
INLETCONNECTION
M. NPT
OUTLETCONNECTION
NPT
WRENCH HEX
FLATS
APPROXIMATE CLOSING FLOWS*
WEBB#LIQUID(GPM
PROPANE)
VAPOR SCHF (PROPANE)25 PSIG INLET
100 PSIGINLET
A8523 Half 3/4” 3/4” Male 1” 15 5,170 8,800 187082A7537L4F Full
2”2” Male
and11/4” Female
2”
75 13,000 25,600 —A7537N4 Half
125 25,000 42,500 189216A7537N4F Full —A7537P4 Half
150 30,500 52,000 162594A7537P4F Full 162595A7539R6F Full
3”3” Male
and2” Female
33/4”
150 32,100 55,500 189217A7539T6 Half
200 39,400 68,300 187043A7539T6F Full 162473A7539V6 Half
250 51,100 88,700 275006A7539V6F Full 189219
* Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down.NOTE: Multiply flow rate by .94 to determine liquid butane flow.
![Page 61: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/61.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Excess Flow, Check, Filler, Vapor Equalizing Valves
55
2SECTION
2
va
lves
& a
cc
es
so
rie
s
Excess Flow Valves for Vapor or Liquid Designed especially for filling, withdrawing or vapor equalizing in half and full coupling installations. Ideal for container service where welded-in dip pipes are not provided. For vapor use, mount in the bottom opening with a threaded dip pipe. For liquid use, mount in the top opening with a threaded dip pipe. These may also be installed in pipe lines provided the connection is made to the male inlet thread and not the female dip pipe connection.
Excess Flow Valves for Liquid or Vapor WithdrawalThese valves are designed for bottom mounting in consumer storage tanks for liquid service. They may also be top mounted for vapor service. These valves are designed especially for use with RegO® globe and angle valves.
A8013D
A2137A
MFR#INLET
CONNECTIONNPT
OUTLETCONNECTION
F. NPTWRENCH
HEX FLATS
APPROXIMATE CLOSING FLOWS***
WEBB#LIQUID (GPM PROPANE)
VAPOR SCHF (PROPANE)25 PSIG INLET
100 PSIGINLET
A2137A 2”* 2” Male and11/4” Female 27/16” 70 14,000 25,000 162415
21393”** 3” Male and
2” Female 31/2”125 26,500 46,000 —
2139A 160 32,700 57,200 308180* 11/4” F. NPT Dip Pipe Connection** 2” F. NPT Dip Pipe Connection *** Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down.NOTE: Multiply flow rate by .94 to determine liquid butane flow and by .90 to determine liquid anhydrous ammonia flow.
MFR#INLET
CONNECTIONNPT
OUTLETCONNECTION
F. NPT*WRENCH
HEX FLATS
APPROXIMATE CLOSING FLOWS**
WEBB#LIQUID (GPM PROPANE)
VAPOR SCHF (PROPANE)25 PSIG INLET
100 PSIGINLET
A8013D11/4”
3/4”1”
398,700 14,700 187071
A8013DA 1” 44 1624912723C 11/4” 3/4” 111/16” 20 3,900 6,900 162418
* 3/4” F. NPT Dip Pipe Connection** Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down.NOTE: Multiply flow rate by .94 to determine liquid butane flow and by .90 to determine liquid anhydrous ammonia flow.
![Page 62: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/62.jpg)
56 victormfg.com
Excess Flow, Check, Filler, Vapor Equalizing Valves 2SECTION
Gas Equipment Catalog
Excess Flow Valve for DOT CylindersDesigned for use on portable systems with vapor or liquid including torches, heaters, lead melting burners, tar and asphalt burners, wallpaper steamers and other applications involving portable DOT cylinders. The POL inlet attaches directly to the cylinder valve and the outlet mounts to the regulator.
Excess Flow Valve for Presssure GaugesDesigned for container use in pressure gauge installations to minimize excess gas discharge in the event the pressure gauges is sheared. A suitable shut-off valve should be installed between this valve and the pressure gauge to allow convenient gauge replacement.
Excess Flow Valve for Flange Mounting in Container ServiceDesigned for container use in pressure gauge installations to minimize excess gas discharge in the event the pressure gauges is sheared. A suitable shut-off valve should be installed between this valve and the pressure gauge to allow convenient gauge replacement.
3199W
MFR#INLET
CONNECTIONNPT
OUTLETCONNECTION
F. NPTWRENCH
HEX FLATS
APPROXIMATE CLOSING FLOWS*
WEBB#LIQUID (GPM PROPANE)
VAPOR SCHF (PROPANE)25 PSIG INLET
100 PSIGINLET
3199W Male POL 1/4” 7/8” .95 265 500 186856
* Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down.NOTE: Multiply flow rate by .94 to determine liquid butane flow and by .90 to determine liquid anhydrous ammonia flow.
MFR#INLET
CONNECTIONM. NPT
OUTLETCONNECTION
F. NPTWRENCH
HEX FLATS
APPROXIMATE CLOSING FLOWS*
WEBB#LIQUID (GPM PROPANE)
VAPOR SCHF (PROPANE)25 PSIG INLET
100 PSIGINLET
2884D 3/4” 1/4” 11/16” N/A 60 110 186836 * Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down.NOTE: Multiply flow rate by .94 to determine liquid butane flow and by .90 to determine liquid anhydrous ammonia flow.
2884D
A3500P4
MFR#INLET
CONNECTIONNPT
FOR INSTALLATION
APPROXIMATE CLOSING FLOWS*
WEBB#LIQUID (GPM PROPANE)
VAPOR SCHF (PROPANE)25 PSIG INLET 100 PSIG INLET
A3500P4 2” Slotted Body 150 30,500 52,000 162591* Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down.NOTE: Multiply flow rate by .94 to determine liquid butane flow and by .90 to determine liquid anhydrous ammonia flow.
![Page 63: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/63.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Excess Flow, Check, Filler, Vapor Equalizing Valves
57
2SECTION
2
va
lves
& a
cc
es
so
rie
s
MFR#INLET
CONNECTIONM. NPT
OUTLETCONNECTION
F. NPTWRENCH
HEX FLATS
APPROXIMATE CLOSING FLOWS*
WEBB#LIQUID (GPM PROPANE)
VAPOR SCHF (PROPANE)25 PSIG INLET
100 PSIGINLET
2884D 3/4” 1/4” 11/16” N/A 60 110 186836
7590U and 7591U Check-Lok® ValvesDesigned with unique 1” NPS threads on both Chek-Lok® outlet and adapter inlet. This helps prevent activation of the Chek-Lok® without use of the 7590U-10 adapter. Extra strength connection between body and adapter provides increased strength. An o-ring seal on adapter provides a gas tight seal before the adapter opens the equalizing stem.These Chek-Loks® are also designed for use on permanent installations provided the excess flow valve is sized properly for the system and piping. NOTE: In some cases, it may be necessary to use an in-line excess flow valve to protect the downstream piping. This valve is not recommended for use as a liquid source for pumps.
Check-Lok® Liquid Evacuation Adapter for 7590U and 7591U ValvesDesigned specifically for use with RegO® 7590U and 7591U Check-Lok® Excess Flow Valves. Adapter’s operating handle opens and closes equalizing stem in the Chek-Lok® valve. Eliminates gas flow through Check-Lok® valve when installing or removing adapter. Use of RegO® adapter ensures proper connections and opening of the check mechanism.
7590U With Cap
7590U-20
7590U—10Union Style Adapter
Union Style Adapters for 7590U and 7591UThe 7590U-10 adapter must be used to connect to the 7590U and 7591U Chek-Lok. This insures a proper connection to open the check mechanism. A built in nylon gasket provides a gas tight seal.
MFR# INLETCONNECTION
OUTLETCONNECTION
BODYWRENCH HEX
FLATS
APPROXIMATEEFFECTIVE
LENGTH
CAPWRENCH
HEX FLATS
APPROXIMATECLOSING FLOW,
LIQUID GPM(PROPAINE)*
WEBB#
7590U 3/4” M. NPT1” UNF
1” 17/16”15/16”
20 1627487591U 11/4” M. NPT 13/4” 111/16” 35 2049018594-1A Nylon Gasket 1869817590U-6 O-Ring 3726407590U-5A Brass Cap 378311
* Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down.NOTE: Multiply flow rate by .94 to determine liquid butane flow and by .90 to determine liquid anhydrous ammonia flow.
7572FC and 7580FC Check-Lok® ValvesDesign is the original Check-Lok. It has provided the LP-Gas industry with quality and dependable performance for over 35 years.
These adapters must be used to connect to the 7572FC and 7580FC Check Loks to open the check mechanism properly. A built in nylon gasket provides a gas tight seal.
7572C-14A 7572C-15A
MFR# INLETCONNECTION
OUTLETCONNECTION
WRENCH HEXFLATS WEBB#
7590U-10 1” UNF 3/4” F. NPT 13/4” 162762
MFR# INLETCONNECTION
OUTLETCONNECTION
WRENCH HEXFLATS WEBB#
7572C-14A3/4” M. NPT
3/4” F. NPT1” 162761
7572C-15A 3/4” M. NPT 162478
MFR# INLETCONNECTION
OUTLETCONNECTION
AWRENCH HEX
FLATS
BAPPROXIMATE
LENGTHWEBB#
7590U-20 15/8” F. UNF 3/4” F. NPT 13/4” 41/8” 2171648594-3A Plug 189195
![Page 64: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/64.jpg)
58 victormfg.com
Excess Flow, Check, Filler, Vapor Equalizing Valves 2SECTION
Gas Equipment Catalog
Double Check Filler Valves for Forklift, Motor Fuel and RV TanksDesigned to provide fast filling of forklift, motor fuel, and recreational vehicle tanks.
Double Check Filler Valves
Double-Check Filler Valves for Large Motor Fuel and ASME TanksDesigned to provide fast filling of large motor fuel and ASME domestic tanks.The 6579 Series incorporates a swing-away lower check which greatly reduces pressure drop across the valve. This lower pressure drop promotes faster filling rates and greater efficiency resulting in more profitable operations.
7647SC
75796579
MFR#(With Lanyard & Cap)
AHOSE
CONNECTION
BTANK
CONNECTIONM. NPT
CWRENCH
FLATS
DEFFECTIVE
LENGTH(APPROX.)
PROPANE LIQUID CAPACITY AT VARIOUS DIFFERENTIAL
PRESSURES (GPM)*** WEBB#10
PSIG20
PSIG30
PSIG40
PSIG50
PSIG7647SA**
13/4” ACME 3/4”11/2” 31/16”
14 20 24 27 50 1908417647SC* 13/4” 21/4”* 162756
* Larger 13/4” hex wrench flats. ** 30º angle on 11/4” ACME hose connection. *** Multiply flow rate by .94 to determine liquid butane capacity.
MFR#ACMEHOSE
CONNECTION
TANKCONNECTION
M. NPT
WRENCHHEX
FLATS
PROPANE LIQUID CAPACITY AT VARIOUS DIFFERENTIAL PRESSURES (GPM)
WEBB#CAP
ONLY
CAP, CHAINAND RING
5PSIG
10PSIG
25PSIG
50PSIG
75PSIG
7579 7579C13/4” 11/4” 1”
50 70 111 157 192 1627457579P* — 37 52 82 116 142 1891806579** 6579C** 78 110 174 246 301 162467
* Incorporates 3/4 F. NPT dip pipe connection. **Swing-away lower back check valve design for higher filling rate. NOTE: Multiply flow rate by .94 to determine liquid butane capacity.
MFR# ACME QUANTITY WEBB#
A2797-20R 11/4” 25 Pack 187010A2697-20R 13/4” 25 Pack 187009A3184-8R 21/4” 20 Pack 187015A3194-8R 31/4” 10 Pack 162538
RegO® Double-Check Filler Valves incorporate a resilient upper check valve, normally designated as a filler valve, and a lower check valve, commonly called a back pressure check valve. Available in a range of sizes to cover virtually all LP-Gas storage containers, these valves are UL listed and meet NFPA standards, as well as other safety requirements.Flow of liquid into the storage container opens both check valves. When flow stops, they both are designed to close automatically to permit the operator to disconnect the hose coupling. The automatic closing action also helps prevent the discharge of container contents in the event of hose failure. The lower back pressure check affords extra protection by restricting the discharge if the upper check fails to function properly due to accidents or other causes.The double back check construction allows emergency inspection, repair, or replacement of the upper fill assembly without removing product from the container. When the upper filler valve body is removed, the lower back check valve provides a seal, permitting only some leakage, allowing a new upper filler valve body to be installed.
Flat Gaskets Buna-N
![Page 65: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/65.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Excess Flow, Check, Filler, Vapor Equalizing Valves
59
2SECTION
2
va
lves
& a
cc
es
so
rie
s
Double Check Vapor Equalizing Valves for ASME and DOT ContainersDesigned to facilitate loading operations by providing equalization of pressures in the supply and storage containers. The supplementary excess flow valve closes when the flow from the container being filled exceeds a predetermined rate.The 7573 Series is designed for use in bulk delivery systems and motor fuel containers. The 3183AC is designed for use in delivery trucks and other large containers.
Double Check Filler Valves for Delivery Truck Tanks and Large StorageDesigned to provide fast filling of bobtails, transports and large bulk storage tanks.The 6587CD incorporates a swing-away lower check which greatly reduces pressure drop across the valve. This lower pressure drop promotes faster filling rates and greater efficiency resulting in more profitable operations.
Back Pressure Valves for Container or Line ApplicationsDesigned to provide protection of a container opening when desired flow is always into the vessel. May be used in line applications where flow must be limited to one direction.When used with the appropriate single check fill valve, the combination forms a double check filler valve suitable for use in filling of bulk storage tanks.
7573DC
7579S
3146
MFR#ACMEHOSE
CONNECTION
TANKCONNECTION
M. NPT
WRENCHHEX
FLATS
APPROX. CLOSING FLOW
AT 100 PSIG INLET PRESSURE
(SCFH/PROPANE)
WEBB#BASIC
WITH CHAIN & CAP
7573D 7573DC 11/4” 3/4” 11/4” 4,100 162744— 3183AC 13/4” 11/4” 2 10,000 250112
MFR# AINLET
CONNECTIONF. NPT
BOUTLET
CONNECTIONM. NPT
CWRENCH
HEXFLATS
DEFFECTIVE
LENGTH(APPROX.)
PROPANE LIQUID CAPACITY AT VARIOUS DIFFERENTIAL
PRESSURES (GPM) WEBB#
BRASS STEEL 5PSIG
10PSIG
25PSIG
50PSIG
3146 —3/4” 3/4” 13/8” 115/16” 11 16 25 36 162578
— A3146 1870123176 —
11/4” 11/4” 2” 13/8” 28 40 63 89 162580— A3176 162581— A3186 2” 2” 27/8” 27/16” 124 175 276 391 162582— A3196 3” 3” 4” 315/16” 297 420 664 939 162583
MFR# ACME HOSECONNECTION
TANK CONNECTIONM. NPT
WRENCHHEX FLATS
PROPANE LIQUID CAPACITY AT VARIOUS DIFFERENTIAL PRESSURES
(GPM) WEBB#5
PSIG10
PSIG25
PSIG50
PSIG75
PSIG7579S 13/4” 11/2” 2” 44 62 98 139 170 162481
Back Pressure Check ValvesRegO® Back Pressure Check Valves are designed to allow flow in one direction only. The check, normally held in the closed position by a spring, precludes the possibility of flow out of the container. When flow starts into the container, the pressure overcomes the force of the spring to open the check. When the flow stops or reverses, the check closes.
![Page 66: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/66.jpg)
60 victormfg.com
Excess Flow, Check, Filler, Vapor Equalizing Valves 2SECTION
Gas Equipment Catalog
MFR# ACME QUANTITY WEBB#
A2797-20R 11/4” 25 Pack 187010A2697-20R 13/4” 25 Pack 187009
Single Check Filler Valves for Storage with Supplementary Back Check ValvesDesigned for use with RegO® Back Check Valves to provide fast filling of bulk storage tanks. Also may be used as a spare or replacement part.These single check filler valves must never be installed directly into container couplings. They must be used with the appropriate back check valve to comply with NFPA Pamphlet #58.
Single Check Vapor Equalizing Valves for ASME and DOT Containers with Supplementary Excess Flow ValvesDesigned for use with RegO® Excess Flow Valves to facilitate loading operations by providing equalization of pressures in the supply and storage containers. Also may be used as a spare or replacement part.These vapor equalizing valves must never be installed directly into container couplings. They must be used with the appropriate excess flow valve to comply with NFPA Pamphlet #58.
Vapor Equalizing ValvesRegO® Vapor Equalizing Valves consist of an upper back check valve and lower excess flow valve. In the closed position, the attachment of a vapor hose coupling with its projecting nozzle, opens the back check valve to permit flow in either direction. The lower excess flow valve is designed to close automatically when flow out of the container being filled exceeds the rated capacity. The valve closes automatically when the coupling is removed. Like the double-check filler valves, the vapor equalizing valves utilize a two-piece body construction. The lower excess flow valve will permit some leakage when the upper back check valve is removed for emergency repairs or replacement.RegO® Vapor Equalizing Valves are designed for use in both ASME and DOT containers.
MFR#ACMEHOSE
CONNECTION
OUTLETCONNECTION
M. NPT
WRENCHHEX
FLATS
PROPANE LIQUID CAPACITY AT VARIOUS DIFFERENTIAL
PRESSURES (GPM)FOR USE WITHBACK CHECK
VALVEWEBB#
5PSIG
10PSIG
25PSIG
50PSIG
3174C 13/4” 11/4” 13/4” 23 33 52 74 3176 1891443194C 31/4” 3” 31/2” 147 208 329 465 A3196 189146
3174C
3170
MFR#INLET
CONNECTIONOUTLET
CONNECTIONWRENCH
HEXFLATS
APPROX. CLOSING FLOW AT 100 PSIG INLET PRESSURE
(SCFH/PROPANE VAPOR)WEBB#
BASICWITH
CHAIN & CAP
3170 — 11/4” 3/4” 11/4” 7,600 189142-— 3180C 13/4” 11/4” 13/4” 10,000 189145
Flat Gaskets Buna-N
![Page 67: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/67.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Excess Flow, Check, Filler, Vapor Equalizing Valves
61
2SECTION
2
va
lves
& a
cc
es
so
rie
s
Bronze Swing Check ValvesClass 300 — Y-Pattern — Threaded EndsFeatures:• Screwed Cap.• Always install with pressure under the disc in vertical or horizontal position.
An arrow cast on the body indicates the correct direction of flow.• MSS-SP-60. Type 3.Working Pressures Non-Shock:300 psi Steam, Basic Rating.1000 psi Cold Working Pressure – 1/4” to 2” (6mm – 50mm).600 psi Cold Working Pressure – 21/2” to 3” (65mm – 80mm).
MFR# WEBB#CRV76E-38 6143CRV76E-12 6144CRV76E-34 6145CRV76E-1 6146CRV76E-114 6147CRV76E-112 6148CRV76E-2 6149
Swing Check Valve
Bronze Lift Check ValvesClass 300 — Threaded EndsFeatures:• MSS-SP-80, Type 1.Suggested to be used on a compressor or similar application with constant pulsating supply. Must be installed horizontally only.Working Pressure Non-Shock:300 psi Steam, Basic Rating.1000 psi Cold Working Pressure.
Lift Check Valve MFR# SIzE WEBB#CRV366E-34 1/4” —CRV366E-1 1” —CRV366E-114 11/4” —CRV366E-112 11/2” —CRV366E-2 2” 6159
![Page 68: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/68.jpg)
62 victormfg.com
Internal Valves & Accessories 2SECTION
Gas Equipment Catalog
11/4” Threaded Internal Valve for Small Capacity Pumping Systems and Bobtail Vapor EqualizationDesigned primarily for use with LP-Gas and anhydrous ammonia as a main valve on small capacity pumping systems, NH3 nurse tanks and in-line installations. It may also be installed in the vapor equalizing opening on bobtail delivery trucks. Installation is quick and easy, and it fits in both full and half couplings, as well as, in-line applications. The valve may be activated manually by hand or cable.
A7883FK
A3209D050
Flomatic® Internal Valves for Bobtail Delivery Trucks, Transports and Large Stationary Storage TanksDesigned primarily for LP-Gas and anhydrous ammonia liquid withdrawal on MC331 bobtail delivery trucks, transports and large stationary storage containers with flanged connections. The valve is fully automatic, opening and closing as the pump is turned on or off.
MFR#INLET
CONNECTIONM. NPT
OUTLETCONNECTION
F. NPT
CLOSING FLOW(GPM)
LP GAS VAPOR CAPACITY
SCFH/PROPANEACCESSORIES
WEBB#LP
GAS NH325 PSIGINLET
100 PSIGINLET
THERMALLATCH
PNEUMATICACTUATOR
A3209D050 11/4” 11/4” 50 45 13300 22900 A3209TL A3209PA 251120A3209D080 11/4” 11/4” 80 72 15700 26700 A3209TL A3209PA 251118
MFR#INLET
CONNECTIONANSI FLANGE
OUTLETCONNECTIONANSI FLANGE
STRAINERWIDTH
BASEWIDTH
OVERALLHEIGHT
(APPROX.)
HEIGHTFROM
INDICATORTO BASE
ACCESSORIESWEBB#
FILTER 3-WAYVALVE
A7883FK 3” - 300# 3” - 300# 43/4” 81/4” 107/8” 413/16” A7884-201 A7853A 162571
A7884FK 4” - 300# 4” - 300# 53/4” 10” 111/4” 415/16” 193215
![Page 69: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/69.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Internal Valves & Accessories
63
2SECTION
2
va
lves
& a
cc
es
so
rie
s
Threaded Internal Valves for Bobtail Delivery Trucks, Transports and Stationary Storage TanksDesigned primarily for use with LP-Gas and anhydrous ammonia for liquid withdrawal; vapor transfer or vapor equalization of bobtail delivery trucks, transports, stationary storage tanks, and in-line installations. The valve may be operated manually by cable or pneumatically.
A3212R105
7605PN-50
MFR#INLET
CONNECTIONM. NPT
OUTLETCONNECTION
F. NPT
CLOSING FLOW (GPM)HALF COUPLING
LP GAS NH3
A3212R1052” 2”
105 95A3212R250 250 225A3212R250-115 — —A3213R150
3” 3”150 135
A3213R300 300 270A3213R400 400 360
MFR#
CLOSING FLOW (GPM)FULL COUPLING ACCESSORIES
WEBB#LP GAS NH3
THERMALLATCH
PNEUMATICACTUATOR
ROTARY PNEUMATIC ACTUATOR
A3212R105 65 59 A3212TL#189207
A3213PA#162570 A3212RA 189206
A3212R250 130 117 187019A3212R250-115 — — — — —A3213R150 125 113
A3213TL#189208
A3213PA#162570 A3213RA
190677A3213R300 250 225 187020A3213R400 325 293 162569
MFR#INLET
CONNECTIONM. NPT
OUTLETCONNECTION
F. NPT
CLOSING FLOW (GPM)HALF COUPLING WEBB#
LP GAS NH3
A3212RT250 2” 2” 250 — 273831A3213T300
3” 3”300 — 224357
A3213T400 400 — 251119
MFR# DESCRIPTION WEBB#
7781AFPN-1 Cylinder assembly kit to convert 7781AF ESVs to pneumatic shutdown. 2417536016-60D Cylinder assembly kit to convert 6016 ESVs to pneumatic shutdown. 359336
7605PN-50 Pneumatic remote shutdown system kit, complete with 100’ of tubing, fittings, 1 charging valve assembly and 1 remote shutdown valve assembly. 189185
7605APN-8A Extra shutdown valve assembly. 2465647605A-BT 100’ roll of 1/4” pneumatic tubing. 1891827605AP-16 1/4” tubing tee, with nuts. 1869357605AP-15 1/8” NPT x 1/4” tubing, straight connector. 1869347605AP-12 Charging Valve Assembly 266444P/HPPB430500 1/4” tubing (per foot) 228691P/HA4MC4MG 1/4” NPT x 1/4” tubing, stright connector 228953P/HA4TU4MG 1/4” tubing tee with nuts 228973P/HA4UC4MG 1/4” tubing union 228974
T Series
ESV Pneumatic Controls
![Page 70: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/70.jpg)
64 victormfg.com
Adapters, Connectors & Fittings 2SECTION
Gas Equipment Catalog
Short Type Hose Couplings for Vapor and Liquid Service
Style AFor Liquid Filling
Style BFor Liquid Filling
Style CFor VaporEqualizing
Style DFor VaporEqualizing
ACME Check Connectors for Lift TrucksThese brass connectors are especially designed to join the carburetor fuel line to the service valve on lift truck cylinders. Sturdy, long lasting ACME threads allow quick, hand-tight assembly that provides for quick and simple cylinder replacement. Back checks automatically close in each connector when disconnected.The 7141M couples directly to the service valve. An integral O-ring is designed to seal before the internal check opens, aiding in product loss prevention. A gasket at the ACME thread is a secondary seal when the connectors are tightened together. The connector fits RegO® lift truck cylinder filling adapters for fast, convenient filling.The 7141F accepts fuel line adapter and couples directly to the 7141M. The O-ring seal in the 7141M is designed to seal before the internal check opens to allow product to pass through the connection. The knurled coupling eases threading and the ACME threads provide rapid effortless make-up, even against LP-Gas pressure.
7141M
7141F
MFR# MATERIAL STYLE HOSE CONNECTIONM. NPT
COUPLING CONNECTIONF. ACME
3175B
Brass A1/2”
13/4”3175 3/4”3175A 1”3185
B11/4” 21/4”
3195 Brass Nut and Steel Nipple 2” 31/4”
A3175
SteelA 3/4” 13/4”A3175A 1”
A3185 B 11/4” 21/4”A3195 2” 31/4”3171A
Brass C1/2“ 11/4”
3181 3/4” 13/4”3181A 1”3191 D 11/4” 21/4”
MFR# TAILPIECE BORE HOSE END TO NUT OVERALL LENGTH WEBB#
3175B 35/64”2” 2”
1868533175
3/4” 1626873175A 1626883185 13/16” 21/16” 3” 1868543195 113/16” 2” 3” 162692A3175
3/4” 2” 2” 257541A3175A 162689A3185 13/16” 2” 3” 187016A3195 113/16” 2’ 3” 1626933171A 17/32” 13/16” 27/16” 1626863181 11/16” 2” 31/4” 1626903181A 15/16” 1” 3” 1626913191 3/16” 2” 35/16” 186855
MFR# APPLICATION INLET OUTLETPROTECTIVE CAP*
WEBB#RUBBER BRASS
7141M Service Valve 3/8” F. NPT 11/4” M. ACME 7141M-40 7141FP 1627557141F Fuel Line 11/4” F. ACME 1/4” F. NPT — — 162754
* Recommended to minimize foreign material entering valves which could result in leakage.
![Page 71: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/71.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Adapters, Connectors & Fittings
65
2SECTION
2
va
lves
& a
cc
es
so
rie
s
Unloading Adapters for Container EvacuationDesigned to provide an efficient means of evacuating an LP-Gas container for relocation or repair. They thread directly onto the 13/4” ACME male hose connection of RegO® Filler Valves used on RegO® Double Check Filler Valves and Multivalves®.The unloading adapters can be used to withdraw liquid provided the container is equipped with a dip pipe extending from the filler valve to the bottom of the container.
Extended Type Hose Couplings for Vapor and Liquid ServiceDesigned especially for liquid filling and vapor equalization of LP-Gas and anhydrous ammonia. The limited travel of the handle on the tailpiece minimizes spin-off, encouraging cautious removal to properly bleed off trapped product to assure closure of the filler valve and hose end valve. The ACME threads are machined on a rugged steel insert which is permanently cast in the aluminum handle, providing for durability under repeated use.
3119A
3120
MFR# STYLE AFILLER VALVE CONNECTION
BHOSE CONNECTION WEBB#
3119A In-Line13/4” F. ACME
13/4” F. ACME 1628303120
Angle 3/4” F. NPT 1628313121 263104
MFR#TYPE
OF SERVICE
HOSECONNECTION
M. NPT
COUPLINGCONNECTION
F. ACMEAPPROX.LENGTH WEBB#
A7575L2*Liquid
1/2”13/4”
7”
275141A7575L3 3/4” 162710A7575L4 1” 162711A7571LB Vapor 3/4” 11/4” 189221
* Includes 7199-33 adapter, shipped loose.
A7575L
3121
![Page 72: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/72.jpg)
66 victormfg.com
Adapters, Connectors & Fittings 2SECTION
Gas Equipment Catalog
ACME Adapters
Filler Hose AdaptersThese adapters are designed with minimal flow restriction and recommended for use on the outlet of the LP-Gas delivery truck filler hose. If the controlled bleed off of the connection indicates the filler valve on the tank being filled has failed to close, the hose adapter should be left in place on the filler valve and disconnection should be made at the regular filler hose coupling. (Repair of the filler valve must be made as soon as possible). An integral check valve in these adapters helps prevent further loss of product. The standard filler valve cap should be attached to these adapters when left on the container.
3179B
7577V
Gasket (Furnished with adapter)ACME X Female NPT
Gasket (Furnished with adapter)ACME X Male NPT
MFR# BUILT-INVENT VALVE
FILLER VALVECONNECTION
HOSECONNECTION
PROPANE LIQUID
CAPACITYAT 80 PSID
WEBB#
7577V Yes13/4” F. ACME 13/4” M. ACME 57 GPM
1627643179B No 1627637576 Yes —
MFR# MATERIAL AM. ACME
BF. NPT
CHEX D E
DIAMETER
FOR SPARE GASKET ORDERMFR#
WEBB#
5764A
Brass
13/4”
1/4”
13/4”
11/2”
3/4” A2697-20R 187009
1624645764B 3/8”
1”
1868655764C 1/2” 1624655764D 3/4” 1868665764E 1” 1626985766E
21/4”1”
21/4” 25/16” 1” A3184-8R 187015 162704
5766F 11/4” 1868685768G
31/4”11/2”
31/2” 3” 2” A3194-8R 162538 194502
5768H 2” 162705
A5764D Steel 13/4” 1” 13/4” 23/16” 3/4” A2697-20R 187009 189210
MFR# MATERIAL AM. ACME
BM. NPT
CHEX D E
DIAMETER
FOR SPARE GASKET ORDERMFR#
WEBB#
5763D
Brass
11/4” 3/4” 11/4” 13/4” 7/16” A2797-20R 187010 189153
5765D13/4”
3/4”13/4”
1” 11/16” A2697-20R 187009 186867
5765E 1” 2” 3/4” 1627005767F
21/4”11/4”
21/4” 25/16”13/16”
A3184-8R 187015
1891545767G 11/2” 1” 1891555767H 2” 2” 27/16” 125/64” 1891565769H
31/4”2” 3” 2” 1” A3194-
8R 162538 1627065769K 3” 31/2” 3” 2” 189158A5765C
Steel13/4”
1/2”
13/4” 23/16”
17/32”
A2697-20R 187009
—A5765D 3/4” 11/16” 189211A5765E 1” 7/8” 162701A5765F 11/4” 15/16” 189212A5769H 31/4” 2” 31/4” 2” 1” A3194-
8R 187015 162707
![Page 73: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/73.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Adapters, Connectors & Fittings
67
2SECTION
2
va
lves
& a
cc
es
so
rie
s
(CGA 510) POL970HT Soft Nose POL
With Handwheel
Male POL Swivel AdaptersMFR# MATERIAL A
M. NPTB
HEXC
DRILL DVAPOR AT 100 PSIG
INLET (SCFH)LIQUID(GPM) WEBB#
970
Brass
1/4”M. NPT
—
5/16” 2”— — 191818
970S 3/16” 23/32” 162771970AX
5/16”25/64” 404 1.10 187003
970AXS 2465653199W 27/16” 450 0.95 186856970AW 1”
21/16”— —
187002970HT — 3” 243117
970JR1/4”
Hose Barb
— 5/32” 2” 190842
MFR# MATERIAL AM. ACME
BM. ACME
CHEX
DDIAMETER
FOR SPAREGASKETORDERMFR#
WEBB#
5765M
Brass
13/4” 13/4” 21/16” — A2697-20R #187009 162703
5767M 21/4” 21/4“ 25/16” 125/64” A3184-8R #187015 189157
5769M 31/4” 1/2” 23/4” 2” A3194-8R #162538 162708
ACME Adapters (continued)
MFR# MATERIAL AM. ACME
BF. NPT
CHEX
DDIAMETER WEBB#
A5764W Steel 13/4” — 11/4” 111/16” 162699
ACME PlugsSpecifically designed to withstand the everyday abuse given hose end valves on delivery trucks and hose end couplings on risers in bulk plants. These rugged plugs protect the coupling tip as well as prevent the entrance of dirt, dust, snow and rain. They also prevent possible gas contamination from these same sources. The heavily ribbed outer surface permits hand-tight make-up.
MFR# MATERIAL M. ACME CHAIN & RING FITS PIPE SIzE UP TO: WEBB#
C5762NNylon
11/4” 3/4” 162463C5765N
13/4”11/4” 162466
5765PR Brass — 250302C5767N
Nylon21/4” 11/4” 187102
C5769N 31/4” 2” 162709
POL PlugsHighly recommended for installation in LP-Gas cylinder valve POL outlets whenever the service line is disconnected or when the cylinder is being transported. When properly installed, the POL plug is designed to prevent contamination of the valve outlet and guards against product leakage if the cylinder valve is accidentally opened.
MFR# MATERIAL CONNECTION WEBB#
N970P CycolacM. POL CGA 510
17949110538P
Brass 1891183705RC 162456
(CGA 510) POL
970 Hard Nose POL
(CGA 510) POL
970AX Hard Nose POL With Excess Flow
50-70MicronFilter
3199W Heavy Duty Hard Nose POL With Excess Flow
N970P
![Page 74: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/74.jpg)
68 victormfg.com
Adapters, Connectors & Fittings 2SECTION
Gas Equipment Catalog
Miscellaneous Adapters
Test AdaptersMFR# MATERIAL A B C
HEX D E F WEBB#
1328Brass
5/8” - 18 UNF 5/8” - 18 UNF1/2”
Hose Barb
13/16” 2” 11/2” 1628161331 3/4” - 16 UNF 3/4” - 16 UNF 15/16” 21/8”
13/4” 1628171332 7/8” - 14 UNF 7/8” - 14 UNF 11/16” 21/2” 162818
MFR# MATERIAL A B WEBB#
15774-1 Brass 1/4” M. NPT Female InvertedFlare 162501
POL Adapters
(CGA 510) POL
Male POL X Male NPT and SAE Flare
(CGA 510) POL
Female POL X Female NPT and Female POL
(CGA 510) POL
Female POL X Male NPT
2906G Male POL X Female NPT(CGA 510) POL
MFR# MATERIAL AM. ACME B C
HEXD
DIAMETER WEBB#
2906ABrass
1/4” 1” 15/16”1/4” 189131
2906G 1/2” 2” 1” 162828
MFR# MATERIAL A B CHEX
DDIAMETER WEBB#
2906D
Brass
3/8”M. NPT 11/16”
15/16” 11/32” 189132
2906F 3/8”SAE Flare
7/8” 9/32”162827
2906E 1/2”SAE Flare 21/4” 162826
MFR# MATERIAL A B CHEX
DDIAMETER WEBB#
5760A
Brass
1/4”15/8” 11/8”
13/32” 1624575760B 3/8” 35/64” 1624585760C 1/2” 43/64” 1624595760D 3/4” 17/8” 13/8”
13/32”162460
5760S POL CGA 510 21/8” 11/8” 163431
MFR# MATERIAL A B CHEX
DDIAMETER WEBB#
5761A
Brass
1/4”
15/8” 11/8”
3/16” 1868635761B 3/8” 13/32” 1868645761C 1/2”
7/16” 1624615761D 3/4” 162462
MFR# MATERIAL A B C WEBB#
1494-1 Brass 12” F. NPT 1/4” F. NPT 1/2” M. NPT 162823
Excess Flow AdaptersMFR# MATERIAL A
M. NPTB
HEXC
DRILL DVAPOR AT 100 PSIG
INLET (SCFH)LIQUID(GPM) WEBB#
3188BBrass 1/2”
M. NPT 1” 5/16” 21/2”700 1.9 246615
3188C 1180 2.9 2466163188 Heavy Duty Hard Nose POL With Excess Flow
![Page 75: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/75.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Miscellaneous Equipment
69
2SECTION
2
va
lves
& a
cc
es
so
rie
s
3144-91Plastic Cap
3175PCap Plug
A5776Reducer Coupling
7141FPCap Plug
907FP
3144-90Metal Cap
1708POL Cap
3194-90GACME Cap With
Stainless Steel Flange
Cap and Reducers
CGA 555 Swivel AdaptersMFR# MATERIAL A B
HexC
Drill D WEBB#
12982 Brass 1/4” M. NPT 11/4” 3/16” 115/16” 190684
3144-91Plastic Cap
3175PCap Plug
A5776Reducer Coupling
7141FPCap Plug
907FP
3144-90Metal Cap
1708POL Cap
3194-90GACME Cap With
Stainless Steel Flange
3144-91Plastic Cap
3175PCap Plug
A5776Reducer Coupling
7141FPCap Plug
907FP
3144-90Metal Cap
1708POL Cap
3194-90GACME Cap With
Stainless Steel Flange
3144-91Plastic Cap
3175PCap Plug
A5776Reducer Coupling
7141FPCap Plug
907FP
3144-90Metal Cap
1708POL Cap
3194-90GACME Cap With
Stainless Steel Flange
3144-91Plastic Cap
3175PCap Plug
A5776Reducer Coupling
7141FPCap Plug
907FP
3144-90Metal Cap
1708POL Cap
3194-90GACME Cap With
Stainless Steel Flange
MFR#
CHaIN & RING FITS PIPe SIze
UP To: CaP oNLy MFR# MaTeRIaLTHRead
CoNNeCTIoN WeBB#3144-91 3/4" 3144-9P 224434 Cycolac 1 1/4" F Acme 186849
3174-91 3174-9P 162832 1 3/4" F Acme 189143
3174-93 1 1/4"
A8016-9P 275116
162451
1708C 3/4" Nylon F POL CGA510 189128
7141FP 1 1/4" Brass 1 1/4" F Acme 189166
3175P 1 3/4" F Acme 192871
5776 1 3/4" M Acme x 3 1/4" F Acme 261759
3184-90 2" A8016-9P 275116 2 1/4" F Acme 162694
5774 2 1/4" M Acme x 3 1/4" F Acme
3194-90 3" 3 1/4" F Acme 162695
A3184-90 2"
Steel
2 1/4" F Acme 162694
A3194-90 3" 3 1/4" F Acme 162695
A5776 1 3/4" M Acme x 3 1/4" F Acme 187024
![Page 76: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/76.jpg)
70
Miscellaneous Equipment 2SECTION
Gas Equipment Catalog victormfg.com
1” Rotogages® for Large Mobile and Stationary ContainersRotogages® are designed to provide an accurate determination of LP-Gas or anhydrous ammonia container contents. They mount in a standard 1” NPT coupling on large mobile or stationary containers.To operate the Rotogages®, the vent valve is opened and the dip tube rotated slowly from the container vapor space to the liquid space. The difference in appearance of the discharge indicates when the liquid level is reached. Dial readings then indicate the percentage of product in the container.
Sight Flow Indicators for Bulk PlantsDesigned to promote maximum pump efficiency, these indicators enable bulk plant operators to visually inspect liquid flow conditions. With glass on both sides of the indicator, flow can be observed from either side, even under some poor light conditions. The integral swing check also serves as a back-check valve to prevent reverse flow and product loss if the hose fails in a loading operation.By installing an indicator on the upstream side of the plant pump, suction conditions can be observed and the pump speed adjusted to obtain the maximum possible flow rate without cavitation. Additionally, if an indicator is installed in the piping at the loading rack, just ahead of the loading hose, the operator can maintain a constant check on pump conditions.Both installations are designed to allow for observation to provide maximum pump efficiency and assure safe plant pump operation.In compressor operations a sign flow indicator installed in the liquid line will give a visual indication when the tank car or transport is emptied. Compressor operation can then be immediately reversed to start recovery of the vapor.
A7794
MFR# WEBB#RGOA9091R —RGOA9092R 162597RGOA9093RS 190686RGOA9093TS 162598RGOA9094RS —RGOA9094TS 162600RGOA9095RS 162602RGOA9095TS 162678RGOA9091-M24.0 —RGOA9091-M36.0 162679RGOA9091-M48.0 162680RGOA9091-M60.0 162681RGOA9091-M72.0 162988
MFR# SERVICECONTAINER
SIzE WEBB#A9091-18L
LP-GasAll Sizes 162682
A9091-18LX* Over 1200U.S. Gallons —
MFR# FOR CONTAINER INSIDE DIAMETERFOR USE WITH LP-GAS FOR USE WITH NH3 ELLIPSOIDAL HEADS HEMISPHERICAL HEADS
For Mobile or Stationary Containers
For Stationary Containers
Only
For Mobile or Stationary Containers
For Stationary Containers
OnlySide
MountedEnd
MountedSide
MountedEnd
Mounted
9091RM24 — AA9091RM24 — 30” - 45” 30” - 75” 30” - 45” 30” - 45”9092RM36 — AA9092RM36 — 46” - 61” 76” - 108” 46” - 61” 46” - 61”
9093TSM48* 9093RSM48 AA9093TSM48* AA9093RSM48 62” - 79” 109” - 147” 62” - 79” 62” - 79”9094TSM60* 9094RSM60 AA9094TSM60* AA9094RSM60 80” - 99” — 80” - 99” 80” - 99”9095TSM72* 9095RSM72 AA9095TSM72* AA9095RSM72 100” - 147” — 100” - 147” 100” - 147”
MFR# INLET/OUTLET CONNECTIONS LENGTH WEBB#A7794 2” F. NPT 53/4” 162712A7796 3” F. NPT 7” 162713
* Dial permits higher filling level, as per NFPA 58, (1983) Par. 4-5.2.1, Table 4.5.2.1
* Supported design. NOTE: The dip tube must be cut to the required length (1/2” of container inside diameter minus 5-3/4”).
![Page 77: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/77.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Miscellaneous Equipment
71
2SECTION
2
va
lves
& a
cc
es
so
rie
s
Pull-Away Valves for Transfer OperationsDesigned especially to provide pull-away protection for LP-Gas and anhydrous ammonia transfer operations including transport and delivery truck loading and unloading, engine fuel container filling and miscellaneous cylinder filling operations. When properly fastened to the inlet end of the discharge hose, the valve is designed to stop gas escape from both upstream and downstream lines in the event of a pull-away. An excessive tension pull causes the valve to automatically separate, closing two internal back pressure checks. Only a few cubic centimeters of gas escape at the instant of separation.It is recommended that a convenient means be provided to safely remove the pressure from the line upstream of each coupling half to enable reassembly of the valve. To reassemble, simply push the male half firmly into the female half until the retaining balls slip into the retaining groove. Check for leaks after reassembly.NOTE: It is recommended that pull-away valves be safety-tested at least monthly to confirm that they will separate properly in the event of a pull-away. Dry nitrogen or other inert gas is suggested for a source of pressure during such tests.
“Swing-Check” ESVs for Bulk PlantsEspecially designed for installation in liquid transfer lines at LP-Gas or anhydrous ammonia bulk plants to provide for quick shut-off of liquid or vapor flow in the event of an accidental pull-away or hose rupture, both of which can cause a fire.
A2141A6L
6016 2” ESV
MFR#INLET/OUTLETCONNECTIONS
NPT F.
DISCONNECTFORCE
APPROX-LBS
RECONNECTFORCE
APPROX-LBS
LENGTH OF
VALVE
LP-GAS LIQUID FLOW CAPACITY AT VARIOUS DIFFERENTIAL
PRESSURES (GPM)*WEBB#5 PSIG 10 PSIG 25 PSIG 50 PSIG
A2141A63/4” 130 80 37/8” 11 16 25 36 162683
A2141A6L** 162684A2141A8 1” 75 50 49/16” 21 30 47 67 187008A2141A10 11/4” 160 25 55/8” 52 75 120 170 189203A2141A16 2” 300 50 145/16” 250 350 550 750 187007
MFR#FOR USE
ONLY WITHINLET/OUTLETCONNECTIONS
LIQUID LOW CAPACITY AT 10 PSIG PRESSURE DROP (GPM) WEBB#
6024 LP 3” F. NPT 427 (NH3) 3949856016 LP 2” F. NPT 427 (NH3) 3087546010 LP 1¼” F. NPT 427 (NH3) 370270
* To determine NH2 liquid flow capacity, multiply by .90.
** Lanyard.
MFR# DESCRIPTION WEBB#6016-60C Pneumatic Open/Close Actuator 3618076016-60D Pneumatic Release for Point of Transfer 359336
![Page 78: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/78.jpg)
72
Miscellaneous Equipment 2SECTION
Gas Equipment Catalog victormfg.com
Hose End Adapters for DOT Cylinder FillingDesigned to provide quick and easy filling of DOT cylinders with POL or Type 1 connections. This adapter may be used with hydraulic and electric automatic systems or with manual systems in conjunction with a RegO® 7901TB Quick Acting Shut-Off valve.These filling connectors have an extended connection on the handwheel, which make it possible to connect the loading hose to valves on cylinders with fixed collars. The handwheel is well outside the collar for easy operation.
Connector for DOT Cylinder Filling AdapterThe 7193T-10 is designed for use on the 7193D-10 Filling Adapters. Connector allows adapter to be used on the 15/16 M. ACME & F. POL connections of Type 1 valves.
7193D-10
7193U-10
7193T-10
Brass Type 1 Fittings & AdaptorsType 1 ACME Appliance Side Fitting X 1/4” Male Pipe
MFR# DESCRIPTION WEBB#G1855-A03 POL Green 71–200 BTU 242866G1855-A02 POL Black 0–70 BTU 182659
Appliance side swivel nut fitting is female 115/16” F. ACME X 1/4” M. NPT. As the appliance side of the Type 1 connection, it makes a positive connection by threading on to the ACME threads of the valve with a user-friendly right hand turn motion.
Threads onto Type 1 cylinder valves just like the appliance side, swivel nut fittings. For purging only.
G-1850 Evacuation Fitting
MFR# WEBB#G-1850 182658
MFR# APPLICATIONS INLETCONNECTION
OUTLETCONNECTION MATERIALS WEBB#
7193D-10Filling of DOT
Cylinders with POL Connections
1/4” M. NPT
M. POL CGA 510
Brass & Stainless Steel 186884
7193U-10Filling of DOT Cylinders with
Type 1 Connections
Type 1 Connection
(115/16” M. ACME)Brass 186886
MFR# APPLICATIONS INLETCONNECTION
OUTLETCONNECTION MATERIALS WEBB#
7193T-10Converts 7193D-10 Adapter from POL to a Type 1 Connection
M. POL CGA 510Type 1
Connection (115/16” M. ACME)
Brass 162472
G-1850
![Page 79: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/79.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Miscellaneous Equipment
73
2SECTION
2
va
lves
& a
cc
es
so
rie
s
Hose End Adapter for Lift Truck Cylinder FillingThe 7193L-10A is designed to provide quick and easy attachment of the filling hose to DOT cylinders equipped with RegO® 714M check connectors.
Lever Operated Hose End Adapter for Fork Lift Cylinder FillingDesigned to drastically reduce labor and time when continuously filling large numbers of lift truck cylinders equipped with RegO® 7141M check connectors.
7193L-10A
7193K-10B
Quick Connect POL Filling AdapterThe 7193R-10 is designed for use in LP-Gas filling systems including fill rooms and dispensing stations. The quick acting lever allows fast connection to POL type (CGA 510) cylinder valves. It fits both compact and heavy duty cylinder valves commonly found on 5 to 100 lbs. DOT LP-Gas cylinders.
7193R-10
Vent ValvesEspecially designed to bleed off liquid or vapor pressures trapped in transfer lines. When installed in the downstream boss of RegO® globe and angle valves used at the end of a liquid transfer hose, the bleeder valve allows for the controlled venting of the product and indicates to the operator that the valves are closed and he can disconnect the coupling. They may also be used as a fixed liquid level gauge where the dip tube is part of the container.3165CP 3165C
Spanner Wrench for ACME ConnectorsThis aluminum spanner wrench is especially designed for use with 21/4” and 31/4” ACME couplings, adapters and caps.
TSS3169
3195-50
MFR# APPLICATION INLETCONNECTION
OUTLETCONNECTION
BODY MATERIAL
ACCESSORIESWEBB#ADAPTER
7193L-10A Filling of Fork Lift Cylinders* 1/4” M. NPT 11/4” F. ACME Brass 5760A 162471
MFR# APPLICATION INLETCONNECTION
OUTLETCONNECTION MATERIALS WEBB#
7193K-10BLever Operated for Quick Filling of Fork
Lift Cylinders1/4” M. NPT Quick Disconnect York Brass and Steel 162470
MFR# APPLICATION INLETCONNECTION
OUTLETCONNECTION WEBB#
7193R-10 Lever Operated for Quick Filling of Cylinders with POL Outlet 1/2” F. NPT Fits Female POL CGA 510 189171
MFR# SERVICE CONNECTION ACTUATION ACCESSORIESWEBB#WARNING PLATE KIT
3165CLP-Gas Only
1/4” M. NPTKnurled
2550-40P162449
3165CP Knurled 186852TSS3169 LP-Gas & NH3 Tee Handle 162450
MFR# FOR USE WITH ACME CONNECTOR SIzE WEBB#3195-50 21/4” & 31/4” 162697
* The 7193L-10A is intended to be permanently attached to the filling hose.
For use with RegO® 7141M check connector.
![Page 80: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/80.jpg)
74
Miscellaneous Equipment 2SECTION
Gas Equipment Catalog victormfg.com
Combination Valve for Bulk Storage ContainersDesigned for installation on bulk storage containers, this valve combines a pressure gauge mounting and provision for a fixed tube liquid level gauge.The shut-off valve prevents the pressure gauge from being subjected to constant pressure, thereby prolonging its life and accuracy. The valve may be closed, and the vent valve opened to vent pressure from the gauge to permit replacement.For fixed liquid level gauging, the valve can be mounted at the maximum permitted filling level. When equipped with a dip tube threaded 1/8” M. NPT, it can be installed at any convenient level.
Needle ValvesThese valves are high quality, “true” throttling valves. Unlike most so-called needle valves, both the body seat and stem are tapered to provide fine, precise control over a wide range of adjustment without stem galling.The 1224 may be used as a small, inexpensive shut-off valve between a pressure gauge and bulk storage container to allow for convenient gauge replacement.The 1316 provides taper pipe thread by left hand hose connection threads and are useful in a wide range of torch and fuel burner applications where an accurate throttling action is required.
Fixed Liquid Level GaugesEspecially designed to provide a visible warning when containers are filled to the maximum permitted filling level. At the start of the filling operation, with the vent stem opened, the valve discharges vapor. When the maximum permitted filling level is reached, the valve discharges liquid. These valves are normally furnished with a 12”, 3/16” O.D. dip tube and incorporate a No. 54 drill size orifice.An optional instruction plate with “Stop Filling When Liquid Appears” may be ordered for use with these valves.
A2805C
1224WA
MFR# SERVICE CONNECTION ACTUATIONDIP
TUBELENGTH
ACCESSORIESWEBB#WARNING
PLATE KIT3165CF05.6
LP-Gas Only 1/4” M. NPTKnurled 5.6”
2550-40P 1891413165CF12.0 Knurled 12” 186851
MFR# CONTAINER CONNECTION SERVICE CONNECTION LIQUID LEVEL VENT WEBB#
A2805C 3/4” M. NPT 1/4” F. NPT for Gauge Mounting Knurled 162685
MFR# Inlet Connection Outlet Connection Height Length WEBB#
1224WA 1/4” M. NPT1/4” M. NPT 19/16” 13/4” 186802
1316WA 9/16” - 18 L.H. 189122
3165CF12.0
![Page 81: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/81.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Diagrams
75
2SECTION
2
va
lves
& a
cc
es
so
rie
s
Check Lok7590U7591U
MultivalveG8475R Series
Pigtail913PS12912PS12
Multivalve7556R Series
Filler Valve65797579
First Stage RegulatorLV4403SR/TR SeriesLV3403TR
Pressure Relief Valve7583G8684G8685G
Underground Line
Twin Stage RegulatorLV404B4 SeriesLV404B9 SeriesLV404B23 SeriesLV404B29 Series
Service Valve9101R Series9101D Series
Filler Valve7647SC with cap
Pigtail912JS12913JS12
Pressure Relief Valve8544 Series
DOT Container
Second Stage RegulatorLV4403B SeriesLV5503B Series
ASME Container
RE GO ROTOGAUG
E
®
Pressure Relief ValveA8436G
RotogageA9093TS
lliF yarpS
nruteR ropa
V
Liquid Fill
Liquid Vapor
Internal ValvesA3213A
Internal ValveA3212R
Internal ValveA3212R
Angle ValveA7704LP
Cap3184-90
Adapters5769H5769K
Cap3184-903194-90
Globe ValveA7517AP
Pump
Internal Valve A3219FA600L
orFlomaticA7884FK
Globe ValveA7513APA7517AP
Adapters5769K
Adapters5767HCap
3184-90A3184-90
Cap3194-90
A3194-90
Bulk Transport Truck
Domestic Installation
![Page 82: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/82.jpg)
76 victormfg.com
Diagrams 2SECTION
Gas Equipment Catalog
RE GO ROTOGAUG
E
CAUTION
Pressure Relief Valve (2)A8434G
Internal ValveA3217F Series
orFlomatic®A7883FK
Pump
Excess Flow Valve7574
Hydrostatic Relief ValveSS8021J
Hose End Valve Filling Connector
A7797A
Cap3175P
Adapter5765F
Globe ValveA7509BP
Internal ValveA3209R050/80
A3209TL
RotogageA9093TSA9094TSA9095TS
Cap3194-90Adapter5769H
Angle ValveA7506AP
Globe ValveA7509BP
Check ValveA3176
Check ValveA3146
Check ValveA3186
Globe ValveA7513AP
Bobtail Delivery Truck
Emergency Shut Off Valves
![Page 83: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/83.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Diagrams
77
2SECTION
2
va
lves
& a
cc
es
so
rie
s
REGO ROTOGAU
G E REGO ROTOGAU
G E
Capacity18,000 to 30,000
Gallons
Angle ValveA7510BP
Pull AwayCouplingA2141A10
Globe ValvesA7509BPA7513AP
CapsC5765NC5769NAdapters
31853195 Pull Away
CouplingA2141A16
Angle ValveA7514AP
HydrostaticRelief Valves
3127U orSS8001U
Liquid ESV6016 Hydrostatic
Relief Valves3127U orSS8001U
Globe ValvesA7513AP
HydrostaticRelief Valves
3127U orSS8001U
Globe ValveA7517AP
Back Check ValvesA3186
RotogageA9095RS
RotogageA9095RS
MultiportA8564A8574
Relief ValvesA3149MG
Internal ValvesA3212RA3213A
Internal ValvesA3212RA3213A
Vapor ESV7781AF
Vapor Line
Angle ValveA7510BP
Pump
To Railroad Cars
By Pass Valve
Liquid Line
Shut-Off ValvesA7513AP
Bulk Storage Plant
Motor Fuel Applications
![Page 84: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/84.jpg)
78 victormfg.com
Repair Kits 2SECTION
Gas Equipment Catalog
Repair Kits Available by Part Number
ECII PART #REPAIR KITS AVAILABLE CONTENTS
INSTRUCTION SHEET # WEBB#
901 Series903 Series
903-50 Bonnet stem and seat disc assembly; large handwheel, self tapping screw 903-300
163019
903-51 Bonnet stem and seat disc assembly; small handwheel, self tapping screw 178960
A2141A6 Series A2141A6-50 O-Ring seal for female connector
A2141A-302 —A2141A6M Male coupling
A2141A8 Series A2141A8-50 O-Ring seal for female connectorA2141A8M Male coupling
A2141A10 A2141A10-50 O-Ring seal for female connector
A2141A-303 —A2141A10M Male coupling
A2141A16 A2141A16-50 O-Ring seal for female connectorA2141A16M Male coupling
A3209A Series A3209A-50 Bearing; cam; gasket; main seat disc assembly; retaining ring, seal-o-ring; seat disc A3209A-301 187018
A3210A Series A3210A-50Bushing, gasket; jam ring; main seat disc assembly; upper and lower retaining rings; o-ring; seal rings(2); seat disc
A3210A-301 —
A3212A SeriesA3212A-K Kits Excess flow spring; o-ring A3212-800 —
A3212A-50 Bearing; cam; gasket; o-rings; seat disc; stem packing A3212A-300 —
A3213A SeriesA3213A-K Kits Excess flow spring; o-ring A3213-800 —
A3213A-50 Bearing; cam; gasket; o-rings; seat disc; stem packing A3213A-300 266446
A3217 Series A3217F-50 Dust seal; jam ring; stem o-ring; stem seals (3); stem spring; stem washer A3217F-300 —
A3217 Series
A3217F-80 O-ring flange
Cotter pin; dust seal; inner and outer stem bearing; jam ring; main and pilot seat disc; poppet seal o-ring; retaining ring; roll pins (2); seat o-ring; stem o-ring; stem seals (3); upper and lower flange seal o-ring; wear button
A3217F-302 —
A3217F-80G Gasket flange
Dust seal; inner stem bearing; jam ring; lower flange seal gasket; main seat disc; outer stem bearing; pilot seat disc; poppet seal o-ring; retaining ring; roll pins (2); seat o-ring; stem o-ring; stem seals (3); upper flange seal gasket; wear button
A3217F-302G —
A3219F Series
A3219F-80 O-ring flange
Bumber; cotter pins (3); dirt seal; inner and outer stem bearing; lever release spring; main seat disc; poppet seat disc; pivot pin locknut; poppet bearing; seal gland gasket; seat seal o-ring; stem jam ring; stem o-ring; stem seal rings (3); stop screw; upper and lower flange seal o-ring
A3219F-302 —
A3219F-80G Gasket flange
Bumber; cotter pins (3); dirt seal; inner stem bearing; lever release spring; lower flange seal gasket; main seat disc; poppet bearing; poppet seat disc; seal gland gasket; seat seal o-ring; stem jam ring; stem o-ring; stem seal rings (3); stop screw; outer stem bearing; upper flange seal o-ring
A3219F-302G —
LV4403 Series See Instruction Sheets Gasket inlet nipple; seat disc assembly 2503-300N —
6532, 6533, 6542, 6543,
Series Filler Valve
6542B-50 Gaskets; spring; spring guide; stem and seat disc assembly; upper body 6542B-300
162513
6542B-80 Gaskets; spring; spring guide; stem and seat disc assembly 162514
![Page 85: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/85.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Repair Kits
79
2SECTION
2
va
lves
& a
cc
es
so
rie
s
Repair Kits Available by Part Number (continued)
ECII PART #REPAIR KITS AVAILABLE CONTENTS
INSTRUCTION SHEET # WEBB#
6532, 6533, 6542, 6543,
Series Service Valve
19104-50Complete MultiBonnet Assembly – bonnet assembly, hardwheel, nameplate and self tapping screw
19104-300 162536
19104-80 Upper packing with seal rings – For MultiBonnet only 19104-800 162537
19105 Bonnet; stem and o-ring assembly; handwheel; self tapping screw 19105-300 —
65797579-50 Gaskets; seat disc and retainer assembly;
spring; upper body 7579-300 186929
7579-80 Gaskets; seat disc and retainer assembly; spring 7579-300A 162523TA7034P
TA7034LP TA7034-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer TA7034-300 —
7141M 7141M-50 Check assembly; gasket; o-ring; retaining ring 7141M-300 1625057177 7177-50 Diaphragm; gasket; o-ring; seat disc; washer 7177-300 1868787188 7188-50 Hydraulic fluid; o-rings; piston; spring; trip latch 7188-300 186881
7193K-10B7193K-50 7193A-51 assembly; adjusting screw; nut;
spring; tee — —
7193K-51 Check body and disc assembly; gasket; nipple; tailpiece nipple; slip washer — —
A7505APA7506AP
A7505-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer A7505-300 —
7505A-20 Bonnet assembly — —A7505APA7506AP TA7034-50 Gaskets; jam ring; o-ring; pressure seal rings;
seat disc; washer TA7034-300 —
A7507APA7508AP
A7507-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer A7507-300 162517
7507A-20 Bonnet assembly — 163075
TA7507AP TA7507-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer TA7507-300 —
TA7509BPTA7509-50 Gaskets; jam ring; o-ring; pressure seal rings;
seat disc; washer TA7509-300 —
7509B-20 Bonnet assembly — —
A7510BPA7509-50 Gaskets; jam ring; o-ring; pressure seal rings;
seat disc; washer A7509-300 162518
7509B-20 Bonnet assembly — —TA7509BPTA7510BP TA7509B-50 Gaskets; jam ring; o-ring; pressure seal rings;
seat disc; washer TA7509B-300 187121A7511APA7511FPA7512APA7512FP
A7511-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer A7511-300 —
7511A-20 Bonnet assembly — —A7511APA7511FPA7512APA7512FP
TA7511A-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer TA7511-300 —
A7513APA7514AP
A7513-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer A7513-300 162520
7513A-20 Bonnet assembly — —
A7513APA7514AP
A7513-20 Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer A7513-300 —
A7513F-20 Bonnet assembly — —TA7513APTA7513FPTA7514APTA7514FP
TA7513A-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer TA7513A-300 162521
![Page 86: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/86.jpg)
80 victormfg.com
Repair Kits 2SECTION
Gas Equipment Catalog
Repair Kits Available by Part Number (continued)
ECII PART #REPAIR KITS AVAILABLE CONTENTS
INSTRUCTION SHEET # WEBB#
A7515APA7516AP
A7517AP/FPA7518AP/FP
A7515-50 Gaskets; jam ring; o-ring; pressure seal rings; roll pin; seat disc; washer A7515-300 162522
A7515-B20 Bonnet assembly — —TA7515APTA7516AP
A7517AP/FPA7518AP/FP
TA7515A-50 Gaskets; jam ring; o-ring; pressure seal rings; roll pin; seat disc; washer TA7515A-300 —
7547B Series7547BX Series7547SX Series
7547B-50 Gaskets; springs; seat disc and retainer assembly; upper body 7547B-300 —
7547B-80 Gaskets; springs; seat disc and retainer assembly 7547B-300A 1869097547DX7547FX7547HX
7547B-80 Gaskets; springs; seat disc and retainer assembly 7547B-300A —
7550P7550UP7551P
7550-15 Bonnet assembly — —
A7550PA7550PXA7551P
A7550-15 Bonnet assembly — —
T553T Series7553T-50 Bonnet; gasket; lever assembly; seat retainer
assembly; stem 7553T-300 —
7553T-80 Gasket; o-ring; seat disc 7553T-301 —
A7553A A7553A-50 Gaskets; o-ring; roll pin; seat disc; spring; stem assembly A7553A-300 —
7554LV7554LAV 7554L-20 Bonnet assembly — —7554SV
7554SAV 7554S-20 Bonnet assembly — —
7556VR,R Series
Service Valve
19104-50Complete MultiBonnet Assembly – bonnet assembly, handwheel, nameplate and self tapping screw
19104-300 162536
19104-80 Upper packing with seal rings – For MultiBonnet only 19104-800 162537
19100-50B Bonnet; stem and o-ring assembly; handwheel; self tapping screw 19105-300 162535
7556VR,R Series
Vapor Equalizing Valve
8475-51A Body; gaskets; spring; stem and seat disc assembly 8475-300 162533
8475-81A Gaskets; spring, stem and seat disc assembly 8475-300A 162534TA7513APTA7513FPTA7514APTA7514FP
TA7513A-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer TA7513A-300 162521
7573A Series 7573A-81 Gaskets; spring, seat disc retainer assembly 7573A-300 —
75797579-50 Gaskets; seat disc and retainer assembly;
spring; upper body 7579-300 186929
7579-80 Gaskets; seat disc and retainer assembly; spring 7579-300A 1625237647B Series 7647B-80 Gaskets; seat disc and retainer assembly; spring 7647B-300 —A7704 SeriesA7705 SeriesA7706 Series
A7705-50 Flange packing; friction washer; gaskets; seat disc A7705-300 187046
A7707LA7708BL
A7707-50 Gaskets; groove pin; jam ring; o-ring; pressure seal rings; seat disc; washers A7707-300 —
A7707-75 Bonnet assembly; packing; seat disc and retainer; stem; washers — 187047
![Page 87: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/87.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Repair Kits
81
2SECTION
2
va
lves
& a
cc
es
so
rie
s
ECII PART #REPAIR KITS AVAILABLE CONTENTS
INSTRUCTION SHEET # WEBB#
A7515APA7516AP
A7517AP/FPA7518AP/FP
A7515-50 Gaskets; jam ring; o-ring; pressure seal rings; roll pin; seat disc; washer A7515-300 162522
A7515-B20 Bonnet assembly — —TA7515APTA7516AP
A7517AP/FPA7518AP/FP
TA7515A-50 Gaskets; jam ring; o-ring; pressure seal rings; roll pin; seat disc; washer TA7515A-300 —
7547B Series7547BX Series7547SX Series
7547B-50 Gaskets; springs; seat disc and retainer assembly; upper body 7547B-300 —
7547B-80 Gaskets; springs; seat disc and retainer assembly 7547B-300A 1869097547DX7547FX7547HX
7547B-80 Gaskets; springs; seat disc and retainer assembly 7547B-300A —
7550P7550UP7551P
7550-15 Bonnet assembly — —
A7550PA7550PXA7551P
A7550-15 Bonnet assembly — —
T553T Series7553T-50 Bonnet; gasket; lever assembly; seat retainer
assembly; stem 7553T-300 —
7553T-80 Gasket; o-ring; seat disc 7553T-301 —
A7553A A7553A-50 Gaskets; o-ring; roll pin; seat disc; spring; stem assembly A7553A-300 —
7554LV7554LAV 7554L-20 Bonnet assembly — —7554SV
7554SAV 7554S-20 Bonnet assembly — —
7556VR,R Series
Service Valve
19104-50Complete MultiBonnet Assembly – bonnet assembly, handwheel, nameplate and self tapping screw
19104-300 162536
19104-80 Upper packing with seal rings – For MultiBonnet only 19104-800 162537
19100-50B Bonnet; stem and o-ring assembly; handwheel; self tapping screw 19105-300 162535
7556VR,R Series
Vapor Equalizing Valve
8475-51A Body; gaskets; spring; stem and seat disc assembly 8475-300 162533
8475-81A Gaskets; spring, stem and seat disc assembly 8475-300A 162534TA7513APTA7513FPTA7514APTA7514FP
TA7513A-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer TA7513A-300 162521
7573A Series 7573A-81 Gaskets; spring, seat disc retainer assembly 7573A-300 —
75797579-50 Gaskets; seat disc and retainer assembly;
spring; upper body 7579-300 186929
7579-80 Gaskets; seat disc and retainer assembly; spring 7579-300A 1625237647B Series 7647B-80 Gaskets; seat disc and retainer assembly; spring 7647B-300 —A7704 SeriesA7705 SeriesA7706 Series
A7705-50 Flange packing; friction washer; gaskets; seat disc A7705-300 187046
A7707LA7708BL
A7707-50 Gaskets; groove pin; jam ring; o-ring; pressure seal rings; seat disc; washers A7707-300 —
A7707-75 Bonnet assembly; packing; seat disc and retainer; stem; washers — 187047
Repair Kits Available by Part Number (continued)
ECII PART #REPAIR KITS AVAILABLE CONTENTS
INSTRUCTION SHEET # WEBB#
A7797A7797-50 Gaskets; groove pin; jam ring; o-ring; pressure
seal rins; seat disc; washers A7797-300 162524
A7797-75 Bonnet and lever asssembly; stem — 162525
A7853A A7853A-50Block v-packing; gaskets; o-rings - piston, stem and yoke; roll pin; seat disc; seat disc retainer assembly; springs
A7853A-300 162526
A7883FK
A7883F-50Bleeder assembly; bushing; cap; cap screws; filters; gaskets; lock washers; needle valve kit; o-rings; retaining ring; roll pin; screen filter; seal; set screws; springs; stem assembly kit; v-ring; x-seal
7883-300 247073
A7883F-80Bushing; cylinder cap screws; filters, gaskets; insert; o-rings; retaining ring; seat disc; v-ring; x-seals
7883-300 —
A7883F-150 Gaskets; seat disc; x-seal 7883-300 189227
A7884FK
A7883F-50
Bleeder assembly; bushing, cap; cap screws; filters; gaskets; lock washers; needle valve kit; o-rings; retaining ring; roll pin; screen filter; screw; seal; set screws; springs; stem assembly kit; v-ring; x-seal
7883-300 247073
A7884F-80 Bushing; cap screws; filters; gaskets; insert; o-rings; retaining ring; seat disc; v-ring; x-seal 7883-300 372636
A7884-150 Gaskets; seat disc; x-seal 7883-300 —
TA7894P TA7894-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer TA7894-300 —
7901 Series7901T-50 Bonnet assembly; gasket; lever 7901-300 1625297901T-80 Gasket; o-ring; seat retainer assembly 7901-301 —
A8016DPA8017 Series
A8018DPA8016B-50 Gaskets; jam ring; o-ring; pressure seal rings;
seat disc; washer A8016B-300 —
A8017DH A8017BH-20R Bonnet stem and seat disc assembly; gasket A8017BH-300 —
G8475RVG8475RWFiller Valve
8475-50 Upper body; gaskets; seat disc ad retainer assembly; spring 8475-300F
162532
8475-80 Gasket; seal; seat disc and retainer assembly; spring 186967
G8475RVG8475RW
Vapor Equalizing Valve
8475-51A Body; gaskets; spring; stem and seat disc assembly 8475-300 162533
8475-81A Gaskets, spring, stem and seat disc assembly 8475-300A 162534
G8475RVG8475RW
Service Valve
19104-50Complete MultiBonnet Assembly – bonnet assembly, handwheel, nameplate and self tapping screw
19104-300 162536
19104-80 Upper packing with seal rings – For MultiBonnet only 19104-800 162537
19100-50B Bonnet; stem and o-ring assembly; handwheel; self tapping screw 19100-300B 162535
G8475RVG8475RW
Fixed LiquidLevel Gauge
3165C Fixed liquid level gauge valve — —
8542G/AA8542 Series 8540-50 Bleeder valve assemblies; packing; gland;set screw; washer; gasket; key 8540-300 —
8547W/VWN 8547-2 Bonnet; o-ring and stem assembly — —
8555D/R SeriesMfg’d 10/9 or before
6542B-50 Gaskets; spring; spring guide; stem and seat disc assembly; upper body 6542B-300
162513
6542B-80 Gaskets; spring; spring guide; stem and seat assembly 162514
![Page 88: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/88.jpg)
82 victormfg.com
Repair Kits 2SECTION
Gas Equipment Catalog
Repair Kits Available by Part Number (continued)
ECII PART #REPAIR KITS AVAILABLE CONTENTS
INSTRUCTION SHEET # WEBB#
8555D/R SeriesMfg’d 10/9 Filler Valve
8555-50 Gaskets; spring; spring guide; stem and seat disc assembly; upper body 8555-300
378312
8555-80 Gaskets; spring; spring guide; stem and seat disc assembly 378313
8555DL 19100-50B Bonnet; stem and o-ring assembly; hardwheel; self tapping screw 19100-300B 162535
8555D SeriesService Valve
19104-50Complete MultiBonnet Assembly – bonnet assembly, handwheel, nameplate and self tapping screw
19104-300 162536
19104-80 Upper packing with seal rings – For MultiBonnet only 19104-800 162537
19100-50B Bonnet; stem and o-ring assembly; handwheel; self tapping screw 19100-300B 162535
8555R SeriesService Valve
19104-50Complete MultiBonnet Assembly – bonnet assembly, handwheel, nameplate and self tapping screw
19104-300 162536
19104-80 Upper packing with seal rings – For MultiBonnet only 19104-800 162537
A/AA 8560 SeriesA/AA 8570 Series 8560-50
Bleeder valve assemblies; seat ring assemblies; pressure seal rings; packing gland; jam ring; washer; gasket
7564-300 —
8593A/AR Filler Valve
8475-50 Gaskets; seat disc and retainer assembly; spring; upper body 8475-300F
162532
8475-80 Gasket; seal; seat disc and retainer assembly; spring 186967
8593A/AR Vapor Equalizing Valve
8475-51A Body; gaskets; spring; stem and seat disc assembly 8475-300 162533
8475-81A Gaskets; spring; stem and seat disc assembly 8475-300A 162534
8593A/AR Service Valve
19104-50Complete MultiBonnet Assembly – bonnet assembly, handwheel, nameplate and self tapping screw
19104-300 162536
19104-80 Upper packing with seal rings – For MultiBonnet only 19104-800 162537
19100-50B Bonnet; stem and o-ring assembly; handwheel; self tapping screw 19100-300B 162535
9101C, D, H, R,P, Y Series
Service Valve
19104-50Complete MultiBonnet Assembly – bonnet assembly, handwheel, nameplate and self tapping screw
19104-300 162536
19104-80 Upper packing with seal rings – For MultiBonnet only 19104-800 162537
19100-50B Bonnet; stem and o-ring assembly; handwheel; self tapping screw 19100-300B 162535
19101-50 Bonnet; stem and o-ring assembly; handwheel (small); self tapping screw 19101-300 —
9103C, D SeriesService Valve
19104-50Complete MultiBonnet Assembly – bonnet assembly, handwheel, nameplate and self tapping screw
19104-300 162536
19104-80 Upper packing with seal rings – For MultiBonnet only 19104-800 162537
19100-50B Bonnet; stem and o-ring assembly; handwheel; self tapping screw 19100-300B 162535
9103T9F 19105-50 Bonnet; stem and o-ring assembly; handwheel; self tapping screw 19105-300 —
9106CO903-50 Bonnet; stem and seat disc assembly;
large handwheel; self tapping screw 903-300163019
903-51 Bonnet; stem and seat disc assembly; small handwheel; self tapping screw 178960
9107K8A, K2A 19100-50B Bonnet; stem and seat disc assembly; handwheel; self tapping screw 19100-300B 162535
9300Y/R
19104-50 Complete MultiBonnet Assembly - bonnet assem-bly, handwheel, nameplate and self tapping screw 19104-300 162536
19104-80 Upper packing with seal rings – For MultiBonnet only 19104-800 162537
19100-50B Bonnet; stem and o-ring assembly; handwheel; self tapping screw 19100-300B 162535
![Page 89: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/89.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Repair Kits
83
2SECTION
2
va
lves
& a
cc
es
so
rie
s
Repair Kits Available for Obsolete Part Numbers
ECII PART #REPAIR KITS AVAILABLE CONTENTS
INSTRUCTION SHEET # WEBB#
1470 LV1480V Series May be replaced with G8475RV Series —
1470W1480W Series May be replaced with G8475W Series —
1470, 1480 SeriesService Valves
3100-80A Bonnet; Diaphragm assembly; stem3100-301 162510
3100-80B Diaphragm assembly; washer 1625113100-81K Conversion kit; bonnet and stem assembly 3100K-300 162512
1470, 1480 SeriesService Valve 1475-80 Seat disc and stem assembly; spring; washer 1475-300F —1470, 1480
Series Vapor Equalizing Valve
2418-51 Body, gasket; seat disc and stem assembly; spring; washer — —
AA1582E SeriesAA1582E-50
Diaphragm and yoke assembly (standard); screen; small spring; stem and seat disc retainer assembly; tetraseals
AA1582E-300 —AA1584E Series AA1584E-300 —AA1586E Series AA158E-300 —
2180 Series Replace with 8555D/R for cylinders with up to 200# propane capacity, for containers with capacities up to 400# use 6533A/R —
2403 Series See Instruction Sheet Gasket; inlet nipple; seat disc assembly 2503-300N —
2418 Replace with G8475RV —2418, 2550
Vapor Equalizing Valve 2418-51 Body, gasket; seat disc and stem assembly; spring; washer — —
2465L, 2486 No repair parts available - replace with G8475RV Series —
2503 Series See Instruction Sheet Gasket; inlet nipple; seat disc assembly 2503-300N —
2250 Replace with G8475RV Series —2250
Vapor Equalizing Valve 2418-51 Body, gasket; seat disc and stem assembly; spring; washer — —
2555 Series Replace with 6532, 6533, 6542, 6543 Series —2577 No repair parts or replacement valve available —
2577 Series Replace with 6532, 6533, 6542, 6543 Series —
![Page 90: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/90.jpg)
84 victormfg.com
Repair Kits 2SECTION
Gas Equipment Catalog
Repair Kits Available for Obsolete Part Numbers (continued)
ECII PART #REPAIR KITS AVAILABLE CONTENTS
INSTRUCTION SHEET # WEBB#
2580, 2581 No repair parts or replacement valve available – replace with 8555D/8555R Series —2593, 2594 Replace with 8593AR16.0 —
2593K, 2594K No replacement available —
2593/K, 2594/KService Valve
3100-80A Bonnet; Diaphragm assembly; stem3100-301 162510
3100-80B Diaphragm assembly; washer 1625113100-81K Conversion kit; bonnet and stem assembly 3100K-300 162512
2593/K, 2594/KFiller Valve 1475-80 Seat disc and stem assembly; spring; washer 1475-300F —
2593/K, 2594/KVapor Equalizing Valve 2418-51 Body; gasket; seat disc and stem assembly;
spring; washer — —
3103 Replace with 9103 for cylinders 100 lbs. or less —
6477AVapor Equalizing Valve
8475-51A Body; gaskets; seat disc and retainer assembly; spring; stem — 162533
5475-81A Gaskets; seat disc and retainer assembly; spring; stem — 162534
6532D, 6533D, 6542D, 6543D
Service Valve
903-50 Bonnet assembly; large handwheel; self tapping screw 903-300
163019
903-51 Bonnet assembly; large handwheel; self tapping screw 178960
6532, 6533, 6542, 6543Filler Valve
6542B-50 Body, gasket; seat disc assembly; spring; stem6542B-300 162513
6542B-80 Gaskets; seat disc assembly; spring; stem 162514
A7016A A7505-50 Gaskets; jam ring, o-ring; pressure seal rings; seat disc; washer A7505-300 —
7555 Replace with 8555D/R Series —7556 Mfg’s before 1962 8100-50 Bonnet assembly; handwheel 8100-300 162531
A7762B, A7727B, A7728B AA1582F-50 Gaskets; flange packing; friction washer;
seat disc A7726B-300 —
7747 Series 7547B-50 Gaskets; seat disct and retainer assembly; spring; upper body 7547B-300 —
8100 Series 8100-50 Bonnet; o-ring and stem assembly; handwheel; self tapping tee 8100-300 162531
8103 Series No repair kits available - replace with 9103 Series —G8475 Mfg’d before
1962 8100-50 Bonnet assembly; handwheel 8100-300 162531
G8475 Filler Valves8475-50 Body; gaskets; seat disc and retainer assembly;
spring 8475-300F 162532
8475-50 Gaskets; seat disc and retainer assembly; spring 186967
G8475Vapor Equalizing Valve
8475-51A Body, gaskets; seat disc and retainer assembly; spring; stem 8475-300 162533
8475-81A Gaskets; seat disc and retainer assembly; spring; stem 8475-300A 162534
8477 Replace with G8475RV —8477 Mfg’d before 1962
Service Valve 8100-50 Bonnet assembly; handwheel 8100-300 162531
![Page 91: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/91.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Repair Kits
85
2SECTION
2
va
lves
& a
cc
es
so
rie
s
Repair Kits Available for Obsolete Part Numbers (continued)
ECII PART #REPAIR KITS AVAILABLE CONTENTS
INSTRUCTION SHEET # WEBB#
8477 Mfg’d before 1962 Vapor Equalizing Valve
8475-51A Body; gaskets; seat disc and retainer assembly; spring; stem 8475-300 162533
8475-81A Gaskets; seat disc and retainer assembly; spring; stem 8475-300A 162534
8484 Mfg’d before 1962 Service Valve 8100-50 Bonnet assembly; handwheel 8100-300 162531
8484A No replacement valves available —8484A
Service Valve 19100-50B Bonnet assembly; handwheel 19100-300B 162535
8484/AVapor Equalizing Valve
8475-51A Body; gaskets; seat disc and retainer assembly; spring; stem 8475-300 162533
8475-81A Gaskets; seat disc and retainer assembly; spring; stem 8475-300A 162534
8555 Series Mfg’d before 1962 No repair parts available – replace with 8555D/R Series —
8555S Series Service Valve
903-50 Bonnet assembly; large handwheel; self tapping screw 903-300
163019
903-51 Bonnet assembly; small handwheel; self tapping screw 178960
8555S Series Filler Valve
6542B-50 Body; gaskets; seat disc assembly; spring; stem6542B-300 162513
6542B-80 Gaskets; seat disc assembly; spring; stem 162514
8593/KFiller Valve
8475-50 Body; gasket; seat disc and retainer assembly; spring 8475-300F 162532
8475-80 Gaskets; seat disc and retainer assembly; spring 186967
8593/KVapor Equilizing Valve
8475-51A Body; gaskets; seat disc and retainer assembly; spring; stem 8475-300 162533
8475-81A Gaskets; seat disc and retainer assembly; spring; stem 8475-300A 162534
8594 Replace with 8593AR16.0 —8594/K Mfg’d before 1962 Service Valve 8100-50 Bonnet assembly; handwheel 8100-300 1625318594/K Mfg’d before 1962 Service Valve 19100-50B Bonnet and stem assembly; handwheel;
self tapping screw 19100-300B 162535
8594/K8475-50 Body; gaskets; seat disc and retainer assembly;
spring 8475-300F 162532
8475-80 Gaskets; seat disc and retainer assembly; spring 186967
8594/K8475-51A Body; gaskets; seat disc and retainer assembly;
spring; stem 8475-300 162533
8475-81A Gaskets; seat disc and retainer assembly; spring; stem 8475-300A 162534
![Page 92: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/92.jpg)
86 victormfg.com
Meters/Meter Accessories 3SECTION
Gas Equipment Catalog
Single Joint Residential Gas MeterR-275, 275 SCFHThese class 250 residential meters are an improved revision of the R-200 family. The latest design concepts and modern engineering materials have been combined to provide a lighter weight, easier to handle, more durable meter which requires less maintenance and offers greater life expectancy. All models stocked are temperature compensated.
Specifications Kits Availablewith swivels, nuts & gaskets included.
MFR#
cApAcityscFh 1/2” w.c. diFF. MAX.
w.p. psi
AppROX. shpG.
wt. LBs
MEtERcONNEctiONs
AVAiLABLE wEBB#But. pROp.R-275-20 Lt.
150 175 5-10 1420 Lt. 244671
R-275-30 Lt. 30 Lt. 244675R-415-30 Lt. 225 260 10-125 21 30, 45 Lt. 244672S-275 150 175 5-10 14 3/4” NPT 181926
MFR# wEBB#R-275-20LTK 181925R-275-30LTK 244642R-415-45LTK 181919
R275
Natural Gas Capacities
Propane
Specifications
* In Stock – Soon to be obsolete
MEtER MOdELcApAcity RAtiNG
At 1/2” w.c. diFFERENtiALcApAcity RAtiNG
At 2” w.c. diFFERENtiAL wEBB#750* 750 Cfh 1600 Cfh 1819241000* 1000 2200 181911
GAuGE pREssuRE (psiG) diFFERENtiAL 750 1600 1000 3000 5000 10000
0.25 2” w.c. 990 990 1360 1860 3100 6200Max. Allow 1340 1340 1850 2520 4200 8400
5 2” w.c. 1120 1120 1540 2100 3500 7000Max. Allow 1630 1630 2240 3060 5100 10200
10 2” w.c. 1260 1260 1740 2370 3950 7900Max. Allow 1920 1920 2640 3600 6000 12000
MEtER MOdEL
MAXiMuM wORKiNG
pREssuRE (psiG)
cApAcity RAtiNG At 1/2” w.c.
diFFERENtiAL OF 0.6 sp. GR.
GAs cFh
cApAcity RAtiNG At 2” w.c.
diFFERENtiAL OF 0.6 sp. GR. GAs cFh
stANdARd cONNEctiONs
750 20 750 1600 45 Lt.1000 25 1000 2200 45 Lt.
3000 wo/flanges* 100 1450 3000 3” - 8” PT5000 wo/flanges* 100 2500 5000 4” - 8” PT10000 wo/flanges* 100 5000 10000 4” - 8” PT
* Special Order
![Page 93: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/93.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Met
er
s/M
et
er
ac
ces
so
rie
sMeters/Meter Accessories
87
3SECTION
3
Natural Gas Capacities SCFH of 0.6 Sp. Gr. Gas at Elevated Pressures
Intermediate and Large Capacity Diaphragm Type Gas Meters (continued)
GAuGE pREssuRE
(psiG) diFFERENtiAL 750 1600 1000 3000 5000 10000
0.25 2” w.c. 1600 1600 2200 3000 5000 10000Max. Allow 1600 1600 2200 3000 5000 10000
5 2” w.c. 1840 1840 2530 3450 5750 11500Max. Allow 2070 2070 2840 3880 6450 12900
10 2” w.c. 2080 2080 2860 3900 6500 13000Max. Allow 2480 2480 3420 4660 7760 15550
15 2” w.c. 2320 2320 3190 4350 7250 14500Max. Allow 2840 2840 3960 5400 9000 18000
20 2” w.c. 2480 2480 3410 4650 7750 15500Max. Allow 3230 3230 4440 5820 10100 20200
25 2” w.c. 2640 3630 4950 8250 16500Max. Allow 3570 4900 6700 11100 22300
40 2” w.c. 3120 5850 9750 19500Max. Allow 4450 8700 13900 27800
50 2” w.c. 3360 6300 10500 21000Max. Allow 5000 9370 15600 31200
70 2” w.c. 3840 7200 12000 24000Max. Allow 5960 11200 18700 37400
100 2” w.c. 4480 8400 14000 28000Max. Allow 7170 13400 22400 44800
MFR#
NAt GAs cAp 1/2”
diFF.
NAt GAs cAp 2” diFF.
NAt GAs cAp 5 psi
NAt GAs 10 psi
Lp cAp 1/2” diFF
Lp cAp 2” diFF.
Lp cAp5 psi
Lp cAp10 psi
R275/S275 275,000 — — — 435,000 — — —R415 415,000 — — 850,000 647,000 — — —750 750,000 1,600,000 1,840,000 280,000 1,866,000 2,463,120 2,786,560 3,134,8801000 1,000,000 2,200,000 2,530,000 3,420,000 2,488,000 3,383,680 3,831,520 4,329,1201600 * 800,000 1,600,000 1,840,000 2,080,000 1,866,000 263,120 2,786,560 3,134,880
(2 PSIG + 14.48 PSIA) / 14.80 PSIA = 1.114 Correction Multiplier for 2 PSI at Sea Level(5 PSIG + 14.48 PSIA) / 14.80 PSIA = 1.316 Correction Multiplier for 5 PSI at Sea Level(10 PSIG + 14.48 PSIA) / 14.80 PSIA = 1.654 Correction Multiplier for 10 PSI at Sea Level
* 100 PSI Max
Quick Reference Meter Capacity Chart
To correct the actual cubic foot index reading to base (standard) conditions, the pressure multiplier is calculated by adding the line (gauge) pressure to the average atmospheric (psia) then dividing by the base pressure (psia).Eg: Pressure Multipler = (10 psig + 14.48 psia) ÷ 14.73 psia = 1.662
![Page 94: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/94.jpg)
88 victormfg.com
Meters/Meter Accessories 3SECTION
Gas Equipment Catalog
How to Identify Parts
MAtERiAL spEciFicAtiONsBody/End Piece Cast Iron Per ASTM A 126 Class BPlug/Cap Stem Cast Brass – ASTM B 584/Alloy 83600 or Alloy 84400Brass Ball CDA3600Brass Nuts & Washers (Plug Valve) ASTM B 584/Alloy B83600 or Alloy 84400 or MPIF Std. 35 CZ 3002O-Rings/Torque Seals Buna-N (Nitrile) or Neoprene RubberPort Seals (Ball Valve) Neoprene RubberUnion Tailpieces Zinc plated yellow dichromate finished steelInsulated Union Tailpieces Zytel nylon insulationUnion Nut Malleable Iron Per ASTM A 47 or Ductile Iron Per ASTM
Multiple Meter ManifoldMFR# dEscRiptiON wEBB#M080KPL070A 11/4” Multiple Meter Manifold With 318128 Two 1” Outlets Spaced 12” On CenterM080KPL070C 11/4” Multiple Meter Manifold With 318127 Three 1” Outlets Spaced 12” On CenterMSAFWWEB01 Meter Manifold Complete 3/4” In 1” Out 318552 With Rego LV4403B66 Regulator, Coated Manifold, Meter Bar With 20 LT Swivels, 1” Dielectric Union
7/8±1/64 PORT
6±1/8 12±1/8
24±1/8
2±1/8
7/8±1/64 PORT
6±1/8 12±1/8
36±1/8
2±1/8
M080KPL070A
M080KPL070C
MSAFWWEB01
![Page 95: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/95.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Met
er
s/M
et
er
ac
ces
so
rie
sMeters/Meter Accessories
89
3SECTION
3
Cast Iron Meter BarsHorizontal Inlet and Outlet6610 Series — 6” Centerline
6610-B Integral FIP
6610-F
Cast Iron Meter BarRear Center Horizontal Inlet and Vertical Outlet (Direct Center/Horizontal Inlet)6722 Series — 6” Centerline
6722-F Femaleinsulatedflatgasketunion
6620-B Integral FIP
6620-F Femaleinsulatedflatgasketunion
For multiple metermanifold applications.
AccessoriesMeter Nuts — 30LT
Meter Nuts are used to connect straight and/oroffsetswivelgasfittingstothegasmeter. Manufactured per ANSI B109.1.
Gasket for Meter Swivels — 20LT & 30LT
Meter Plugs are used to prevent the unintentionalflowof gasfrommetersetswithout meters attached. They also prevent insects and other foreign matter from entering the gas piping.
Meter Plugs — 20LT
Gaskets are used to seal malleable iron offsetorstraightfittingsonthefaceof thegas meter when tightening the swivel nut on meter thread of meter nut plug. These rubber gaskets made of Buna-N or neoprene are resistant to the action of natural and manufactured gases. The inside diameter is intended to lightly grip the pilot O.D. of thefittingtominimizeproblemsduringassembly of the swivel nut to the meter
A B c1 1 20LT
MFR# dEsc. wEBB#AYM6610-f-1X1X1 1” 250082
MFR# dEsc. wEBB#AYM6722-C-C Swivels 250083
MFR# dEscRiptiON wEBB#EQU0016115402000 20 LT Washer 244635EQU0016115503000 30 LT Washer 244638EQU0016215502000 45 LT Washer 244643EQU0014116600000 20 LT Black Nut 244636EQU0014116707000 30 LT Black Swivel Nut 244639EQU0014116800000 45 LT Black Nut 244644A B c
1 1 20LT
Cast Iron Meter Bars With Integral SwivelsHorizontal Inlet and Outlet6620 Series — 6” Centerline
A B c1 1 1
Steel Fabricated Accessories
pROduct MFR# dEscRiptiON suppORt wEBB#BRKL-6 6” Wall Bracket Riser 252457BRK9h 9” Wall Bracket Riser 253223BRK38-01 14” Adjustable Wall Bracket Riser 192635
Brackets for Risers
![Page 96: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/96.jpg)
90 victormfg.com
Cylinders, Tanks & Accessories 4
Gas Equipment Catalog
SECTION
Steel Cylinders4.25 lbs. to 60 lbs. LPG CylindersWorthington’s steel portable cylinders in eight sizes for commercial, industrial, recreational and home applications. These cylinders are manufactured to Department of Transportation (DOT) 4BA-240 specifications.
MFR# vAlve size webb#G/T4.5-OPD Type 1 With OPD 4.5 lbs. 194227G/T11-OPD Type 1 With OPD 11.0 lbs. 194228G/T20-OPD Type 1 With OPD 20 lbs. 190980G/T30-OPD Type 1 With OPD 30 lbs. 190983G/T40-OPD Type 1 With OPD 40 lbs. 194229G/T43 POL Valve 43.5 lbs. 223351G/T60 POL Valve 60 lbs. 185251
6.5 in./165.1 mm
11.6
25 in
./29
5.3
mm
9.12
5 in
./23
1.8
mm
4.25 lbs.
6.5 in./165.1 mm
16.6
25 in
./42
2.3
mm
9.12
5 in
./23
1.8
mm
11 lbs.
6.5 in./165.1 mm
17.6
25 in
./44
7.6
mm
12.1
25 in
./30
8 m
m
20 lbs.
6.5 in./165.1 mm
23.6
87 in
./60
1.6
mm
30 lbs.
12.1
25 in
./30
8 m
m
6.5 in./165.1 mm
12.1
25 in
./30
8 m
m29
.250
in./
743
mm
40 lbs.
6.5 in./165.1 mm
12.1
25 in
./30
8 m
m32
.5 in
./82
5.5
mm
43.5 lbs.
6.5 in./165.1 mm
42.2
in./
1071
mm
12.2
5 in
./31
1 m
m
60 lbs.
MFR# DesCRipTion webb#G/T20H-OPD 20# Horizontal Cylinders 259991G/T30H-OPD 30# Horizontal Cylinders 259992G/T40H-OPD 40# Horizontal Cylinders 253750
G/T20H-OPD G/T40H-OPD
size 4.25 lbs. 11 lbs. 20 lbs. 30 lbs. 40 lbs. 43.5 lbs. 60 lbs.
LPG Capacity 1.0 gal.3.8 liters
2.6 gal.9.8 liters
4.7 gal.17.9 liters
7.1 gal.26.8 liters
9.4 gal.35.7 liters
10.3 gal.38.8 liters
14.2 gal.53.5 liters
Water Capacity 12.0 lbs.5.4 kg.
26.2 lbs.11.9 kg.
47.6 lbs.21.6 kg.
71.5 lbs.32.4 kg.
95.2 lbs.43.2 kg.
103.6 lbs.47.0 kg.
142.9 lbs.64.8 kg.
Tare Weight 11.9 lbs.5.4 kg.
13.8 lbs.6.3 kg.
17.0 lbs.7.7 kg.
25.4 lbs.11.5 kg.
33.6 lbs.15.2 kg.
34.4 lbs.15.6 kg.
48.0 lbs.21.8 kg.
Collar Height 4.0 in.101.6 mm
4.0 in.101.6 mm
4.0 in.101.6 mm
4.0 in.101.6 mm
4.0 in.101.6 mm
5.1 in.129.5 mm
5.1 in.130.2 mm
Footring Dia. o/s
9.1 in.231.2 mm
7.8 in.198.4 mm
7.8 in.198.4 mm
7.8 in.198.4 mm
7.8 in.198.4 mm
12.0 in.304.8 mm
12.00 in.304.8 mm
G/T30H-OPD
![Page 97: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/97.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
cy
lin
der
s, Ta
nk
s &
ac
ces
so
rie
sCylinders, Tanks & Accessories
91
4
4
SECTION
Aluminum Cylinders6 lbs. to 40 lbs. LPG CylindersAttractive, corrosion-resistant aluminum makes the ideal cylinder for home and recreational use. These cylinders are lightweight and easy to handle, but durable for the most demanding applications. The exterior finish is smooth and sleek. The interior is clean, dry and free of foreign matter. All aluminum cylinders meet DOT-4E specifications.
MFR# vAlve size webb#G/TA6-OPD Type 1 With OPD 6 lbs. —G/TA10-OPD Type 1 With OPD 10 lbs. —G/TA20-OPD Type1 With OPD 20 lbs. 185252G/TA30-OPD Type1 With OPD 30 lbs. 185253G/TA40-OPD Type1 With OPD 40 lbs. 254110
size 6 lbs. 10 lbs. 20 lbs. 30 lbs. 40 lbs.
LPG Capacity 1.4 gal.5.4 liters
2.4 gal.9.8 liters
4.7 gal.17.9 liters
7.1 gal.26.8 liters
9.4 gal.35.7 liters
Water Capacity 15.0 lbs.6.8 kg.
23.8 lbs.10.8 kg.
47.6 lbs.21.6 kg.
71.5 lbs.32.4 kg.
95.2 lbs.43.2 kg.
Tare Weight 8.0 lbs.3.6 kg.
10.1 lbs.4.6 kg.
14.1 lbs.6.4 kg.
18.0 lbs.8.2 kg.
20.9 lbs.9.5 kg.
Collar Height 6.5 in.165.1 mm
5.5 in.139.7 mm
5.5 in.139.7 mm
5.5 in.139.7 mm
5.5 in.139.7 mm
Steel Motor Fuel Cylinders33.5 lbs. Forklift CylindersSteel forklift cylinders feature two-piece construction with one horizontal weld for a stronger, better looking cylinder with less chance of leakage. The rugged, damage- resistant footring minimizes future repairs. Interior cylinder walls are smooth, dry and free of foreign matter.
Aluminum Motor Fuel Cylinders33.5 lbs. Forklift CylindersWorthington combines the highest standards of manufacturing quality with the light weight and durability of aluminum to provide you lift truck cylinders that readily return your investment through savings in handling, repairs, maintenance, and customer preference. Manufactured in accordance with DOT-4E240 specifications.
MFR# DesCRipTion size webb#G/TA33MF Aluminum, No Filler Valve 331/2 lbs. —G/TA33MFA Aluminum, 13/4 M. ACME Filler Valve 331/2 lbs. 185255
MFR# DesCRipTion size webb#G/T33MF No Filler Valve 331/2 lbs. 185239G/T33MFA 13/4 Filler Valve 331/2 lbs. 185240G/T43MFA 13/4 Filler Valve 431/2 lbs. 252696
12.5
in./
317.
5 m
m26
.75
in./
679.
45 m
m
33.5 lbs.
A: Universal float gaugeB. Liquid service valveC. Safety relief valveD. Fixed liquid levelE. Vapor service (plugged)F. Liquid fill port (plugged)
Motor Fuel Cylinders
![Page 98: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/98.jpg)
92 victormfg.com
Cylinders, Tanks & Accessories 4
Gas Equipment Catalog
SECTION
DOT/ASME LPG Cylinders 100, 200, & 420 lbs. Cylinders• Exceptional quality and service. Manufactured to DOT, Transport Canada or
ASME specifications.• All gas containment welds are automatic MIG/submerged arc welds. • All tanks are 100% leak tested before and after mechanical valve installation.• All tanks pretreated with chemical wash to improve corrosion resistance and
powder coating adhesion.• Worthington’s manufacturing process minimizes odorant fade and maximizes
paint coating quality.• Worthington’s Durabond 2000 powder paint finish is the highest quality and most
durable powder coating available in the industry.• Tank interiors are clean, dry, and free of foreign matter.• Can be used in multiple cylinder installations.• Now with the industry’s largest diameter “user friendly” collar for more work room
during filling.• On-time delivery and competitive pricing. Readily available during peak season to
service new business.
100 lbs.
6.5 in./165.1 mm
14.6
25 in
./37
1.5
mm
48.5
in./
1232
mm
A: Multi-Valve (3/4”) NPTB: NPT Float Gauge (!”) NPT
DoT CylindersMFR# vAlve size ColoR webb#G/T100ASME Tall 100# ASME Less Gauge 100 lbs. White 263468G/T100ASME-G 100# Squat With Gauge 100 lbs. White 269529G/T100 POL Service 100 lbs. Gray 185223G/T100M Multivalve 100 lbs. Gray 185226G/T100MW Multivalve 100 lbs. White 194259G/T200 Multivalve 200 lbs. White 185229G/T200G Multivalve 200 lbs. Gray 192637G/T100M Multivalve 200 lbs. Gray 185226G/T420 Multivalve POL 420 lbs. White 185243G/T420G Multivalve POL 420 lbs. Gray 192638
Composite Cylinder PadsMFR # DesCRipTion webb#VCT420PAD Composite Pad for 420/200 433676
![Page 99: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/99.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
cy
lin
der
s, Ta
nk
s &
ac
ces
so
rie
sCylinders, Tanks & Accessories
93
4
4
SECTION
AsMe CylindersMFR# vAlve size ColoR webb#G/T200ASME Multivalve 200 lbs. White 190984G/T200ASMEG Multivalve 200 lbs. Gray 193312G/T420ASME Multivalve POL 420 lbs. White 185244G/T420ASMEG Multivalve POL 420 lbs. Gray 193311
420 lbs.
16 in./407 mm
51.7
in./
1313
.2 m
m
30 in
./76
2 m
m
200 lbs.
16 in./407 mm
39.7
in./
1008
mm
24 in
./61
0 m
m
Description and Size of 420# L.P.G. Cylinder Openings
A: Safety Relief Valve (1”) NPTB: Fill Valve (3/4”) NPTC: NPT Float Gauge (1”) NPTD: Vapor Service Valve (3/4”) NPT
Open Collar100# CylindersMFR # DesCRipTion webb#PIGME350A Multivalve 186562
How to Order a Truckload11 bundles make up a truckload. Special colors, or plastic mesh protective coatings are available upon request. There is a quantity of 9-420’s in a bundle, and 16-200’s in a bundle. You must specify DOT or ASME style tanks at time of order. Minimum order of 3 bundles is considered a partial truckload. No more than 3 different stops per truckload within a 150 mile radius.
size 100 lbs. 200 lbs. 420 lbs.
LPG Capacity 23.6 gal.89.3 liters
47.2 gal.178.5 liters
99.1 gal.374.9 liters
Water Capacity 239.0 lb.108.4 kg.
474 lbs.215.0 kg.
1000 lb.453.6 kg.
Tare Weight 71.0 lb.32.2 kg.
158.0 lb.71.7 kg.
272.0 lbs.123.4 kg.
Collar Height 5.1 in.130.2 mm
6.6 in.167.6 mm
6.6 in.167.6 mm
Footring Dia. o/s 14.5 in.368.3 mm
19.0 in.482.6 mm
22.0 in.558.8 mm
G/T100ASME
G/T100ASME-G
DOT/ASME LPG Cylinders (continued)
![Page 100: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/100.jpg)
94 victormfg.com
Cylinders, Tanks & Accessories 4
Gas Equipment Catalog
SECTION
Underground/Aboveground Tanks
Underground Tanks
NotesThe chart for AG models is applicable to AG/UG and UG models with the following exceptions:120 and 150 AG/UGs—stack drops from 14 to 12.250 and 320 UGs—stack drops from 9 to 5 tanks.475 and 500 UGs—stack drops from 6 to 5 tanks.• A full load must measure between 46’ and 50’.• We can ship 52’ (not allowed in some states) if the load meets additional criteria. (Must be all AG tanks)
AG/UG Tank
500 Aboveground Tank with 11/4 Bottom Opening for Fill Stations
All 1000 AG come standard with bottom 11/4 NPT opening.
MFR#CApACiTy
in w.g.oveRAlllengTh
ouTsiDeDiAMeTeR
(in)
oveRAll heighT
wiTh 26” RiseR weighTnuMbeR
peR sTACknuMbeR
peR loAD webb#G/T120UG 120 5’ - 8” 24” OD 32” 260 12 96 265267G/T250UG 250 7’ - 8” 30” OD 38” 480 5 30 185234G/T320UG 320 9’ - 6” 30” OD 38” 620 5 25 185238G/T500UG 500 10’ - 0” 37” OD 65” 940 5 25 185249G/T1000UG 1000 15’ - 10” 41” OD 69” 1800 5 15 185225
Aboveground Tanks
MFR#CApACiTy
in w.g.oveRAlllengTh
ouTsiDeDiAMeTeR
(in)leg
spACingweighT
(lbs)nuMbeR
peR sTACknuMbeR
peR loADwebb#(whiTe)
webb#(gRey)
G/T120AG 120 5’ - 7” 24” OD 371/2” 260 14 112 205731 —G/T250AG 250 7’ - 8” 30” OD 60” 480 9 54 185233 198025G/T320AG 320 9’ - 6” 30” OD 60” 620 9 45 185237 —G/T500AG 500 10’ - 0” 37” OD 60” 940 6 30 185248 198024G/T1000AG 1000 15’ - 10” 41” OD 138” 1800 5 15 185224 —
MFR#CApACiTy
in w.g.oveRAlllengTh
ouTsiDeDiAMeTeR
(in)
oveRAllheighT
w/ RiseRleg
spACingweighT
(lbs)nuMbeR
peR sTACknuMbeR
peR loAD webb#G/T120AG/UG 120 5’ - 8” 24” OD 36” 371/2” 260 12 96 185228G/T250AG/UG 250 7’ - 9” 30” OD 40” 60” 480 9 54 202413G/T320AG/UG 320 9’ - 11” 30” OD 40” 60” 620 9 45 193388G/T500AG/UG 500 10’ - 0” 37” OD 47” 60” 940 6 30 194172G/T1000AG/UG 1000 15’ - 10” 41” OD 51” 138” 1800 5 15 204553
MFR#CApACiTy
in w.g.oveRAlllengTh
ouTsiDeDiAMeTeR
(in)leg
spACingweighT
(lbs) webb#G/T500AG-B 500 10’ - 0” 37” OD 60” 950 215818
![Page 101: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/101.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
cy
lin
der
s, Ta
nk
s &
ac
ces
so
rie
sCylinders, Tanks & Accessories
95
4
4
SECTION
Complete Remote Fuel Level and Temperature Monitoring System
DOT vs. ASME
DOT vs. ASME
DOT vs. ASME Similar in that:
DoT AsMe240 psi Working Pressure 250 psi Working Pressure
325 Test Pressure 375 Test PressureRe-Inspection After 12 Years No Current Re-Inspection Requirements
Transportation Legal With Product No Transportation With More than 5% Product
DoT AsMeWeld Repairable Not Weld Repairable **Licensing Required
Heat Treated During Manufacture Not Heat Treated During ManufactureNo Information Data Plate Information Data Plate
70,000 Tensile 75,000 Tensile
Similar Wrapper ThicknessSame Valves Save the Pressure ReliefSame Strong Wide CollarSame Strong FootringSame LiftlugsSame Valve Configurations on 420’sAll Vacuum Purged
RSS has other accessories to suppport custom installations.
MFR# DesCRipTion 1000ag 1000ug 420 30k bulk webb#
REC-1 Controller; Modem Only 432208RECINT-1 Controller; Modem and Internet x x x x 432209ITP-1 Solar Powered Transmitter x x x x 432205SEN-1-24 Standard 24” Sensor Cable x x 432210SEN-1-24-RA Right Angle 24” Sensor Cable for Under-
ground Tankx 432211
ITP-1-STOR Storage Tank Transmitter with Magnetic L Bracket.
x 432206
SEN-MAG-XX Sensor for Magnetel Dial with up to 96” length. XX= length. 96” will locate the transmitter on the side of a 30,000 tank. Does not include dial.
x 432212
BATT-ITP-1 Battery Pack for Integrated Transmitter (ITP-1); Installation tool to activate a 6 second RF transmission rate.
Reusable. One required
per installation
432203
CABLE 9V Contoller Cable; Installation tool to allow walkabout testing of receiver.
432204
PROG Handheld Programmer 432207
Remote Level IndicatorMFR # DesCRipTion webb#RBSRS-228 Remote Level Indicator 314605
![Page 102: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/102.jpg)
96 victormfg.com
Cylinders, Tanks & Accessories 4
Gas Equipment Catalog
SECTION
“Wall Hugger” Cylinder ViseBig Performance, Small ProfileThe unique design of this powerful cylinder vise allows you to replace cylinder valves quickly and easily, yet does not require a lot of valuable dock space. The “Wall Hugger” actually uses less floor space than this catalog!
MFR# DesCRipTion webb#AMDCV-1 Cylinder Vise 202780
“Wall Hugger” Cylinder Vise
Pump Station EnclosureProtect Your Equipment• Double doors, Heavy duty load bearing floor.• Adjustable top shelf.• “Duty to Warn” decals.• Tamper resistant hardware.
Pump Station Enclosure
MFR# DesCRipTion webb#PS302LD 68” X 44” X 30” —PS303LD 68” X 44” X 39” 184880
“Little Giant” Stationary Tank InverterWill lift and invert all cylinders from a single (or double) 100# thru a full 420#. Indexes to 90°, 180° or 45° to facilitate valve relacement, evacuation and bottom maintenance. Doubles as a vice. Small 3’ X 4’ base saves dock space.
MFR# DesCRipTion webb#AMDLG Tank Inverter 184881
“Little Giant” Tank Inverter20 Pound Cylinder CabinetsMFR# DesCRipTion webb#AMDLB06302SS 6 Capacity 202790AMDLB12302MS 12 Capacity, 3 Wide 202792
Fork Lift CabinetsMFR# DesCRipTion webb#AMDFH12302LS 12 Capacity, 3 Wide, Horizontal 202791AMDFV06302MS 12 Capacity, 3 Wide, Vertical 202793AMDFH16402LD 16 Capacity, 4 Wide, Horizontal 202794
Portable Beam Utility ScaleModel 1124ApplicationsA general purpose, 1000 lbs., portable scale utilizing a mechanical beam for industrial and commercial use.MFR# DesCRipTion webb#FBS1124 Portable Beam Scale 181957
Features & Benefits• 1000 lbs. capacity.• 17.75” X 23.5” platform.• Rugged, cast iron base, lever system and platform are designed for durability.• Easy to read, brass beam insert will not fade in direct sunlight.• Easy to maneuver with built-in wheels.• Conforms to NTEP standards for weighing food, commodities, propane and more.
42.5
” Ta
ll
![Page 103: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/103.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
cy
lin
der
s, Ta
nk
s &
ac
ces
so
rie
sCylinders, Tanks & Accessories
97
4
4
SECTION
Cylinder Hand Trucks
MFR# DesCRipTion webb#HPR70416 For LP Cylinders 182214VCTNMP79004P For 420 lbs. Cylinders 190693
Cylinder Hand Truck
Appliance TruckMFR# webb#HPREA6061 182215
Appliance Truck
Methanol InjectorMFR # DesCRipTion webb#VCTTMI-1QL Methanol Injector 215392
TMI-1QL Methanol Injector
MFR# DesCRipTion webb#RIMABJ2 Methanol Injector Hand Held Pump Style 186594
Hand Held Pump Style
POL Valve Wrench Kit
MFR# DesCRipTion webb#VCT201 Polished POL Plugs 184417VCT202 Valve Wrench 184418VCT203 Handle 20-3 184419
Handle
Wrench
POL Adapter
OPD Cylinder Vise Wrench KitThe Best Way to Install OPD Cylinder ValvesThe TTW-3 is a totally new concept in valve wrenches. It quickens installation and removal of QC cylinder valves from DOT containers. The wrench works on all Style 1 (QC) valves, particularly the fixed handwheel OPD’s that are mandated by the DOT for all 5 lbs. to 40 lbs. cylinders.
The TTW-3 mates to the cylinder valve QC thread, rather than the POL thread, reducing the possibility of valve deformation when removing or installing. The wrench seats flush against the valve face, distributing torque across a wider area. And the compact TTW-3 fits under the handwheel valve and allows rotation inside the cylinder collar, simplifying the removal and installation procedure.
The TTW-3 also incorporates a bleed orifice safety feature that will indicate any pressure remaining in the cylinder before removing the valve by simply opening the valve slightly prior to loosening. The wrench is made from tough, durable alloy and forged steel components. This long-lasting construction resists corrosion and distortion.
MFR# webb#VCTTTW-3 192938
![Page 104: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/104.jpg)
98 victormfg.com
Cylinders, Tanks & Accessories 4
Gas Equipment Catalog
SECTION
500 gal. of water X 8.345 (pounds per gallon) = 4172.5 lbs. of water – tank weight (940#) = 3232.5 pounds of buoyancy to overcome.
Pad length and width must be converted to feet in the chart below to have the calculator formula’s to work correctly. Good engineering practice would be to make the pad at least 1 ft. (6 inches on each side) bigger than the container so the stainless anchors only have a direct vertical pull when attached to the stainless coated cable. 3/8” coated cable should provide enough tensile strength to overcome the bouyancy factor.
FACToRs lbs1 CU Yard of Concrete 4000
CU ft. of Concrete 148CU ft. of Water 62.41 Gal. of Water 8.345
1 CU Yard of Sand 24001 CU Yard of Dirt (Clean Humus or Fill) 3800
Conversion Factors
quAliTy sTeel TAnk size
pAD lengTh
(Min)
pAD wiDTh (Min)
weighT oF
TAnkTAnk h20 CApACiTy
buoyAnCy FACToR neeDeD
To keep in gRounD 4” pAD 6” pAD 9” pAD 12” pAD
120 U/G (5’ 8” L X 24” OD) 5.583 3 260 120 741.4 818.0212 1239.426 1859.139 2478.852250 U/G (7’ 8” L X 30” OD) 7.666 3.5 480 250 1606.25 1310.426 1985.494 2978.241 3970.988320 U/G (9’ 6” L X 30” OD) 9.5 3.5 620 320 2050.4 1623.93 2460.5 3690.75 4921
500 U/G (10’ 0” L X 37” OD) 10 4.08 940 500 3232.5 1992.672 3019.2 4528.8 6038.41000 U/G (15’ 10” L X 41” OD) 15.833 4.417 1800 1000 6545 3415.594 5175.143 7762.714 10350.29
This calculator is for general reference only. When in doubt have an engineer design a system to your individual job specification and local code requirements.
Tank Buoyancy Chart for Concrete Pad Size
Magnesium AnodesMagnesium anodes have a 10’ length of #12 electric wire attached.
MFR# DesCRipTion webb#Anode 17 #17 183403Anode 5 #5 215998
Typical Small ASME Container Underground Installationiron pipe Anode Requirements pipepipe size lengThInstall 0ne 5 lbs. Anode 3/4” 500’11/4” 450’11/2” 425’2” 400’Install 0ne 17 lbs. Anode 3” 700’14” 500’6” 400’8” 350’
Typical Tank Anode Requirements 17 lbs. AnoDes TAnk size RequiReD500 gals. 11,000 gals. 23,000 gals. 4400 to 5,000 gals. 610,000 gals. 815,000 gals. 1020,000 gals. 1225,000 to 30,000 gals. 14
Pipe WrapMFR# DesCRipTion webb#KMC4130 Yellow Pipe Wrap, 2” X 100’ 243386PAS9052R Black Pipe Wrap, 2” X 100’ 81161MISUD21 Underground Gas Detector Tape 183516VCTTRACER Tracer Wire 500’ – 14GA 359306ELE1207PE30-4E Tracer Wire 500’ – 12GA 243218
![Page 105: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/105.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
cy
lin
der
s, Ta
nk
s &
ac
ces
so
rie
sCylinders, Tanks & Accessories
99
4
4
SECTION
Propane Storage VesselsThe withdrawal of propane vapor from a vessel lowers the contained pressure. This causes the liquid to “boil” in an effort to restore the pressure by generating vapor to replace that which was withdrawn. The required “latent heat of vaporization” is surrendered by the liquid and causes the temperature of the liquid to drop as a result of the heat so expended.
The heat lost due to the vaporization of the liquid is replaced by the heat in the air surrounding the container. This heat is transferred from the air through the metal surface of the vessel into the liquid. The area of the vessel in contact with vapor is not considered because the heat absorbed by the vapor is negligible. The surface area of the vessel that is bathed in liquid is known as the “wetted surface”. The greater this wetted surface, or in other words the greater the amount of liquid in the vessel, the greater the vaporization capacity of the system. A larger container would have a larger wetted surface area and therefore would have greater vaporization capacity. If the liquid in the vessel receives heat for vaporization from the outside air, the higher the outside air temperature, the higher the vaporization rate of the system. How all this affects the vaporization rate of a 100 lbs. cylinder is shown in a following section (return to contents and see 100# DOT cylinders. You will note that the worst conditions for vaporization rates are when the container has a small amount of liquid in it and the outside air temperature is low.
Simple formulae for determining the proper number of DOT cylinders and proper size of ASME storage containers for various loads where temperatures may reach 0°F will be found in the sections on 100# DOT Cylinders and ASME Storage tanks respectively
Determining Total LoadIn order to properly size the storage container, regulator and piping, the total BTU load must be determined. The total load is the sum of all gas usage in the installation. It is arrived at by adding up the BTU input of all appliances in the installation. The BTU input may be obtained from the nameplate on the appliance or from the manufacturers literature.
Future appliances which may be installed should also be considered when planning the initial installation to eliminate the need for a later revision of the piping and storage facilities.
Where it may be more desirable to have ratings expressed in CFH, divide the total BTU load by 2516 for CFH of propane.
Approximate BTU Input for Some Common AppliancesAppliAnCe AppRox inpuT (bTu peR houR)Range, Free Standing, Domestic 65,000Built-in Oven or Broiler, Domestic 25,000Built-in Top Unit, Domestic 40,000Water Heater, Quick Recovery, Automatic Storage 30 Gallon Tank 30,000 40 Gallon Tank 38,000 50 Gallon tank 50,000Water Heater, Automatic Instantaneous 2 gal./min. 142,800 4 gal./min. 285,000 6 gal./min. 482,000Refrigerator 3,000Clothes Dryer, Domestic 20,000Incinerator, Domestic 32,000
100# DOT Cylinders“Rule of Thumb” Guide for Installing 100 lb. Cylinders For continuous draws where temperatures may reach zero F. Assume the vaporization rate of a 100 lb. cylinder as approximately 50,000 BTU per hour.Number of Cylinders per side = Total load in BTU’s 50,000 Example:Assume total load = 200,000 BTU/hr.Cylinders per side = 200,000 = 4 cylinders per side. 50,000
This chart shows the vaporization rate of containers in terms of the temperature of the liquid and the wet surface area of the container. When the temperature is lower or if the container has less liquid in it, the vaporization rate of the container is a lower value.
Vaporization Rate 100 lbs. Propane Cylinders (approximate)
lbs. oFpRopAne
in Cyl.
MAxiMuM ConTinuous DRAw in bTu peR houR AT vARious
TeMpeRATuRes in DegRees F.
0 20 40 60 70100 113,000 167,000 214,000 277,000 300,00090 104,000 152,000 200,000 247,000 277,00080 94,000 137,000 180,000 214,000 236,00070 83,000 122,000 160,000 199,000 214,00060 75,000 109,000 140,000 176,000 192,00050 64,000 94,000 125,000 154,000 167,00040 55,000 79,000 105,000 131,000 141,00030 45,000 66,000 85,000 107,000 118,00020 36,000 51,000 68,000 83,000 92,00010 28,000 38,000 49,000 60,000 66,000
![Page 106: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/106.jpg)
100 victormfg.com
Cylinders, Tanks & Accessories 4
Gas Equipment Catalog
SECTION
ASME Storage ContainersDetermining Propane Vaporization Capacity“Rule of Thumb” Guide for ASME LP-Gas Storage Containers
WhereD = Outside diameter in inchesL = Overall length in inchesK = Constant for percent of volume of liquid in container
L
D
* These formulae allow for the temperature of the liquid to refrigerate to -20°F (below zero), producing a temperature differential of 20°F for the transfer of heat
from the air to the container’s “wetted” surface and then into the liquid. The vapor space area of the vessel is not considered. Its effect is negligible.
Vaporizing Capacities for Other Air TemperaturesMultiply the results obtained with the above formulae by one of the following factors for the prevailing temperature.
peRCenTAge oFConTAineR FilleD
kequAls
pRopAne vApoRizATionCApACiTy AT 00 F (in bTu.hR.)*
60 100 D X L X 10050 90 D X L X 9040 80 D X L X 8030 70 D X L X 7020 60 D X L X 6010 45 D X L X 45
pRevAiling AiRTeMpeRATuRe(in DegRees F) MulTiplieR
pRevAiling AiRTeMpeRATuRe(in DegRees F) MulTiplieR
-15 0.25 +5 1.25-10 0.50 +10 1.50-5 0.75 +15 1.750 1.00 +20 2.00
![Page 107: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/107.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
cy
lin
der
s, Ta
nk
s &
ac
ces
so
rie
sCylinders, Tanks & Accessories
101
4
4
SECTION
Quality Steel Replacement PartsQS PART # DESCRIPTION MFR # WEBB # ALT. MFR # ALT. WEBB #Tank Size 120 01-001 Filler Valve 7579-T 162745 01-009-1 Float Gauge B8981-1186 HA-130AQ 31579201-021 Multi Valve, Tube length 6.7 7556-RS 162742 01-007 Relief Valve 7583-GT 162747 01-031 U/G Float Gauge JB-302 315650 Tank Size 150 01-001 Filler Valve 7579-T 162745 01-009-1 Float Gauge B8981-1186 HA-130AQ 31579201-021 Multi Valve, Tube length 6.7 7556-RS 162742 01-007 Relief Valve 7583-GT 162747 01-008-1 Check Lok 7590-UT 162748 01-031 U/G Float Gauge JB-302 315650 Tank Size 250 01-001 Filler Valve 7579-T 162745 01-010-1 Float Gauge HA 156-AQ 315681 01-023 Multi Valve, Tube length 8.5 7556-RS 162742 01-007 Relief Valve 7583-GT 162747 01-008-1 Check Lok 7590-UT 162748 01-017 U/G Float Gauge, L.N.R. JB350B 315667 JB332BRN 31580701-045 U/G Float Gauge, S.N.R. JB224B Tank Size 320 01-001 Filler Valve 7579-T 162745 01-010-1 Float Gauge HA 156-AQ 315679 01-023 Multi Valve, Tube length 8.5 7556-RS 162742 01-007 Relief Valve 7583-GT 162749 01-008-1 Check Lok 7590-UT 162748 01-017 U/G Float Gauge, L.N.R. JB350B 315661 JB332BRN 31580701-045 U/G Float Gauge, S.N.R. JB224B Tank Size 475 01-001 Filler Valve 7579-T 162745 01-011-1 Float Gauge HA 194-AQRN 315679 01-002 Multi Valve, Tube length 10.5 7556-RS 162742 01-012 Relief Valve 8684-GT 162749 01-008-1 Check Lok 7590-UT 162748 01-018 U/G Float Gauge, L.N.R. JB384B 315661 JB370FP-J09 31580601-046 U/G Float Gauge, S.N.R. JB260C Tank Size 500 01-001 Filler Valve 7579-T 162745 01-011-1 Float Gauge HA 194-AQ 315679 01-002 Multi Valve, Tube length 10.5 7556-RS 162742 01-012 Relief Valve 8684-GT 162749 01-008-1 Check Lok 7590-UT 162748 01-018 U/G Float Gauge, L.N.R. JB384B 315661 JB370FP-J09 31580601-046 U/G Float Gauge, S.N.R. JB260C Tank Size 1000 01-001 Filler Valve 7579-T 162745 01-016-1 Float Gauge HA 210-AQ 315793 HA210ARN 31567701-025 Multi Valve, Tube length 11.3 7556-RS 162742 01-013 Relief Valve 8685-GT 162750 01-008-1 Check Lok 7590-UT 162748 01-019 U/G Float Gauge, L.N.R. JB404B 315657 JB386ERN 31580501-047 U/G Float Gauge, S.N.R. JB280C
![Page 108: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/108.jpg)
102 victormfg.com
Paint & Supplies 5SECTION
Gas Equipment Catalog
Premium Industrial CoatingsPrimersA single package epoxy primer of high quality that offers excellent corrosion resistance and fast re-coat time. This product is user friendly and offers great coverage.
MFR# deScRiPtion webb#SUM855G1368 Gray-Green Primer 184237SUM899W1370 Off White Primer 184238
MFR# deScRiPtion webb#SUM880N2209 Foot Ring Protector, Black 184248
MFR# deScRiPtion webb#SUM880W2203 No. 5 Blued White Tank Enamel 184244SUM880W2201 No. 7 Silicone Alkyd White 184249
MFR# deScRiPtion webb#SUM880S2205 SC1000 Tank Coating, Aluminum 184233SUM880S2206 SC1110 Strontium Chromate, Aluminum 184234SUM880S2207 Aluminum Enamel Paint 184235
MFR# deScRiPtion webb#SUM880G0166 Green Enamel 184182SUM880L0184 Tan Enamel 184239SUM885N2100 Black Enamel 184240SUM880D0130 Mist Gray 184236SUM885R2108 Red 184241SUM886Y8625 Industrial Yellow 184245
Primers
Foot Ring Protector
White Paint
Aluminum Paint
Enviro-Tuff Industrial Enamels
MFR# deScRiPtion webb#SUM856X2210 XL Thinner 184251
Foot Ring ProtectorA protective coating that is modified with phenolic resins making this a great product for the bottoms of cylinders. When applied properly, this product aids in corrosion resistance. Can be mopped, brushed or sprayed.
White PaintBlued White Tank enamel was formulated especially for Propane Tanks offering elasticity, excellent weathering, one coat coverage, and user friendly. Works great with rollers, brushing and also can be sprayed. Silicone Alkyd White is the premium of our Tank Enamels, modified with high percentage of silicone offering excellent gloss and color retention. This product is highly recommended for painting storage tanks when maximized coating life is a must.
Aluminum PaintTank Coating is our most popular aluminum finish that has nearly 2 pounds of aluminum paste in every gallon. SC1000 was formulated using premium blend of oleoresinous varnishes. Strontium Chromate is the premium in our aluminum finishes, all the same great qualities of our SC1000 plus the addition of built in rust inhibitor.
Enviro-Tuff Industrial EnamelsA high quality industrial enamel offered in an assortment of colors to personalize your tanks. This product is great for many other exterior uses.
Paint Thinner
![Page 109: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/109.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
pa
int
& s
up
plie
sPaint & Supplies
103
5SECTION
5
Paint AccessoriesMFR# deScRiPtion webb#SUMSC-TTB002 12” Trim Brush 184250SUMKM-1009 5 Gal. Bucket 192127SUMSC-BC003 Bucket Cover (3 Per Pkg.) 192913SUMSC-BG-001 Bucket Grid 242094SUMSCL9V14 9” Lambswool Roller Cover 184195SUMSC-CR006 Contour Roller Cover 184192SUMSC-TR09K 9” Roller Handle 184247SUMSC-EP03P 42” Extension – 3 pc. 242095SUMSC-WB042 Pole Wire Brush —SUMSC-CR063 Contour Roller Complete 264998
12” Trim Brush 5 Gallon Bucket
Bucket Grid
Bucket Cover
Lambswool Roller Cover
Roller HandleContour Roller
Complete
Wire Brush
42” Extension
Coverage Data: Enamels and PrimersPremium Industrial Coatings (continued)
The above data is theoretical and may vary slightly from batch to batch and also in dependent on amount of paint actually applied.
Coverage Data: Aluminums and Primers
The above data is theoretical and may vary slightly from batch to batch and also in dependent on amount of paint actually applied.
tank Size(GallonS)
aPPRox Sq. Feet
no. 5 blued white
no. 7 Silliconealkyd white
100d8431hi SolidS
uni-Pox PRiMeR1370 oFF white
uni-Pox PRiMeR1368 GRay GReen
30,000 1,950 7 Gallons 7 Gallons 7 Gallons 7 Gallons 7 Gallons18,000 1,250 5 Gallons 5 Gallons 5 Gallons 5 Gallons 5 Gallons12,000 1,150 4 Gallons 4 Gallons 4 Gallons 4 Gallons 4 Gallons1,000 225 1 Gallons 1 Gallons 1 Gallons 1 Gallons 1 Gallons500 115 2 Tanks Per Gallon 2 Tanks Per Gallon 2 Tanks Per Gallon 2 Tanks Per Gallon 2 Tanks Per Gallon250 55 4 Tanks Per Gallon 4 Tanks Per Gallon 4 Tanks Per Gallon 4 Tanks Per Gallon 4 Tanks Per Gallon
Sq. Ft.Coverage per
Gal. at 1 dry mil— 740 760 810 785 785
Recommendeddft. per coat — 1.5 - 2.5 mils
295 - 495 Sq. Ft.1.5 - 2.5 mils
305 - 505 Sq. Ft.1.5 - 2.5 mils
325 - 540 Sq. Ft.1.5 - 2.5 mils
315 - 520 Sq. Ft.1.5 - 2.5 mils
315 - 520 Sq. Ft.
tank Size(GallonS)
aPPRox Sq. Feet
Sc 100aluMinuM tank
coveRinG
Sc 1110StRontiuMchRoMate
Sc 2000non-GlaRealuMinuM
hiGh SolidSuniveRSal
PRiMeR
ePoxy eSteRPRiMeR 1370oFF white
30,000 1,950 8 Gallons 8 Gallons 7 Gallons 7 Gallons 8 Gallons18,000 1,250 5 Gallons 5 Gallons 5 Gallons 5 Gallons 6 Gallons12,000 1,150 4 Gallons 4 Gallons 4 Gallons 4 Gallons 5 Gallons1,000 225 1 Gallons 1 Gallons 1 Gallons 1 Gallons 1 Gallons500 115 2 Tanks Per Gallon 2 Tanks Per Gallon 2 Tanks Per Gallon 2 Tanks Per Gallon 2 Tanks Per Gallon250 55 4 Tanks Per Gallon 4 Tanks Per Gallon 4 Tanks Per Gallon 4 Tanks Per Gallon 4 Tanks Per Gallon
Sq. Ft.Coverage per
Gal. at 1 dry mil— 635 665 740 810 615
Recommendeddft. per coat — 1.5 - 2.5 mils
255 - 425 Sq. Ft.1.5 - 2.5 mils
265 - 445 Sq. Ft.1.5 - 2.5 mils
295 - 495 Sq. Ft.1.5 - 2.5 mils
325 - 540 Sq. Ft.1.5 - 2.5 mils
250 - 415 Sq. Ft.
![Page 110: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/110.jpg)
104 victormfg.com
Signs/decals 5SECTION
Gas Equipment Catalog
Signs & DecalsReflective Warning Scotchlite DecalsMFR# deScRiPtion Size webb#S22-A Railroad Crossing 8” X 36” —S22-B Railroad Crossing 4” X 36” 181431S22-C Railroad Crossing 8” X 12” 309162S29 Railroad Crossing 4” X 36” —
S22-A
S22-B S22-C
S29Fuel Signs
MFR# deScRiPtion Size webb#V72 Safety First (Blue Only) — —V288-BB Propane Gas — 192754V58 LPG (Black On Orange) 21/2” X 3” —P101 Capacity Chart (Red/Blue On Poly) — 260991V62 Sheet of 10 2# Labels (Black On Yellow) 4” X 51/2” 309285V47 Propane 9” X 38” 372646
Unless otherwise indicated, the items following are red letters on white background. M = Metal (Aluminum) S = Scotchlite® Brand Reflective V = Vinyl P = Polyethylene (plastic)
A = 6” letters B = 4” letters BB = 3” letters C = 2” letters D = 1” letters
V72
V288-BB
V58
CYLINDER FILLINGCAPACITY CHART
W.C. LBS. PROPANE
2.39
4.78
7.17
9.56
11.9
14.3
16.7
19.1
21.5
23.9
26.2
28.6
31.0
33.4
1
2
3
4
5
6
7
8
9
10
11
12
13
14
W.C. LBS. PROPANE
35.8
38.2
40.6
43.0
45.4
47.8
59.7
71.7
78.8
83.6
95.6
105.1
119.5
239
1
2
3
4
5
6
7
8
9
10
11
12
13
14
P101
PROPANE GAS 2 P.S.I.PROPANE GAS 2 P.S.I.PROPANE GAS 2 P.S.I.PROPANE GAS 2 P.S.I.PROPANE GAS 2 P.S.I.PROPANE GAS 2 P.S.I.PROPANE GAS 2 P.S.I.PROPANE GAS 2 P.S.I.PROPANE GAS 2 P.S.I.PROPANE GAS 2 P.S.I.
V47 V62
Updated Test & Retest KitsMFR# deScRiPtion Size webb#V31 Periodic Inspection Chart 6” X 18” —V32 5 Year Inspection Kit 6” X 18” 359351
V31
No Smoking SignMFR# deScRiPtion Size webb#V49 No Smoking Vinyl (Stick-On Decal) 10” X 42” 188815
V49
V32
Placard HolderMFR# deScRiPtion webb#MPH69 .050 Aluminum With Baked Enamel Finish 181423 & Stainless Steel Clip
MPH69
D.O.T. Placarding for Bulk TransportersMFR# deScRiPtion webb#V1075 Vinyl 181435P1075 Polyethylene 181426G1075 Magnetic Blanket 181418
V1075P1075G1075
![Page 111: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/111.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
pa
int
& s
up
plie
sSigns/decals
105
5SECTION
5
Signs and Decals (continued)
Storage Tank Diamond for PropaneRed, Yellow, Blue & Black on White Vinyl
MFR# deScRiPtion Size webb#V704-3 300’ Legibility 15” X 15” 308184V704-1 100’ Legibility 7.5” X 7.5” 269724
V704-3V704-1
Danger SignMFR# deScRiPtion Size webb#SP53-R Black On Yellow Vinyl 4” X 9” 181434
Filling Procedure DecalsMFR# deScRiPtion Size webb#V121 Vinyl 11” X 12” 192753P121 Polyethylene 11” X 12” 269726V122 Vinyl 11” X 12” 309161P122 Polyethylene 11” X 12” 269725V79 Black on Yellow Vinyl 2” X 31/2” —
V121/P121 V122/P122
V79
OPD SignsMFR# deScRiPtion Size webb#P114 RetrofitChart(Blue On White Poly) 18” X 24” 359348P111 Alert Sign (4 Holes & 2 Colors) 16” X 20” 251721
P114
P111
Liquid/Vapor SignsMFR# deScRiPtion Size webb#V90 Red On White Vinyl 1” X 4” —V90-5 Red On White Vinyl (5 per Sheet) 1” X 4” 309284V91-5 Red On White Vinyl (5 per Sheet) 1” X 4” 269723
V90
V90-5 V91-5
Emergency SignsMFR# deScRiPtion Size webb#V81 Pull – Red On White Vinyl 10” X 12” —P81 Pull – Red On White Polyethylene 10” X 12” 359350V82 Push – Red On White Vinyl 10” X 12” —P82 Push – Red On White Polyethylene 10” X 12” 19275211-V-127 Red On White Vinyl 12” X 30” —11-P-127 Red On White Polyethylene 12” X 30” —
V81/ P81
11-V-12711-P-127
V82/ P82
![Page 112: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/112.jpg)
106 victormfg.com
Signs/decals 5SECTION
Gas Equipment Catalog
Portable Cylinder LabelsMFR# deScRiPtion Size webb#A16 Curved, Black Imprint — 181416AA16 Not Curved — 181417A53 Black on White Vinyl 1.5” X 5” 223683
A16 (Curved)
AA16
A53
Signs and Decals (continued)
MFR# deScRiPtion Size webb#HZ116 Blue, Yellow, Red & Black 21/2” X 5” 181419
Hazard Sign
Propane Filling Station SignsMFR# deScRiPtion Size webb#M97A Single Faced (Blue On White Aluminum) 2’ X 4’ 181421M97-AX Exchange (Blue On White Aluminum) 2’ X 4’ —M97-AD Double Faced (Blue On White Aluminum) 2’ X 4’ 181413M97-AXD Exchange (Blue On White Aluminum) 2’ X 4’ —V14 Red & Black On White Vinyl 12” X 16” 309160C37 Red & Black On Coroplast 12” X 24” —M97-FR Frame for 2’ X 4’ Signs With Hardware — 181444
MFR# deScRiPtion webb#B/S42001 Portable Label Pusher 193975
MFR# deScRiPtion webb#MISSIGNDV Direct Vent Appliance Below 309803
M97A, M97AD M97AX, M97AXD
V14
C37No Smoking While Refueling DecalsMFR# deScRiPtion Size webb#V266 Red On White Vinyl 24” X 36” —V26-A Red On White Vinyl 12” X 18” 309159V26-B Red On White Vinyl 12” X 18” —M26-C Baked Enamel On Aluminum 24” X 36” 181441
Label MakerVersaPrinter™Quickly create any type of label or sign and print as many as you need in a matter of minutes. . . right from your own computer!
![Page 113: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/113.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ga
ug
es
Gauges
107
6SECTION
6
GaugesThe “One” Gauge™ Adjustable Liquid-Level Gauge49SApplicationThe “One” Gauge™ is a magnetically-coupled liquid-level gauge that adjusts in length and accepts a variety of float stem lengths. This feature makes it easy to quickly and economi-cally replace non-functional gauges in the field for a large variety of tank sizes. They are UL listed.
General Information & FeaturesThis gauge features a range of adjustable stems which, when mated with an appropriate-length float assembly, enables LP Gas dealers to easily replace the liquid-level gauge in virtually all LP Gas tanks used for domestic storage or mobile applications. Models are available with Junior™ bolted heads in aluminum or brass, Senior™ bolted heads in aluminum, and a version with a Junior™ 11/4” or 1” male NPTF brass head.
The design utilizes a square-brass centershaft telescoping inside a square-aluminum pinionshaft, both of which are housed in telescoping aluminum support tubes. An aluminum locknut compresses an aluminum locking sleeve to secure the tubes at the required stem length. All other components are of the same materials as standard Rochester LP Gas gauges. The proper float assembly is attached to the gear housing on the adjustable stem per instructions shown below.
Materials of ConstructionHeadAluminum or BrassDrive MagnetAlnicoCentershaftBrassPinionshaft & Support TubesAluminumGears, Cross Stud, & BearingsStainless Steel
Gear HousingZincApprovalsGauges are UL listed for LP Gas Service Applications
When ordering, specify: 1. Gauge head size ( Jr., Sr., 11/4” NPTF, or 1” NPTF).2. Aluminum or brass.3. Tank diameter, shown on nameplate.4. Mounting location (top, side, end, or angle).5. If the gauge is angle mounted, state the degree of angle above or below the horizontal centerline, or the distance in inches above or below the horizontal centerline to the center of the gauge opening.6. If the gauge is end mounted, state the shape of the tank head (hemispherical or semi-ellisoidal).7. Specify the “H” dimension. This is the distance in inches from the surface of the tank to the top of the mounting surface.
![Page 114: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/114.jpg)
108 victormfg.com
Gauges 6SECTION
Gas Equipment Catalog
Gauges
MFR# DesCRIptIon Webb#0049S02159bp Jr. 121/2” to 193/4” brass Head 3591390049S02170bp Jr. 191/2” to 331/4” brass Head 361810
Adjustable LP Gas GaugesJr. Adjustable Gauges—Less Float
Sr. Adjustable Gauges—Less Float
1” Adjustable Gauges—Less Float
11/4” Adjustable Gauges—Less Float
Float Assemblies
Adjustable Kits
MFR# DesCRIptIon Webb#0049S02207p Sr. 121/2” to 193/4” Alum. Head 3591360049S02208p Sr. 191/2” to 331/4” Alum. Head —
MFR# DesCRIptIon Webb#0049S02160bp 1” - 121/2” to 193/4” brass Head 3591370049S02167bp 1” - 191/2” to 331/4” brass Head 362437
MFR# DesCRIptIon Webb#0049S02203bp 11/4” - 121/2” to 193/4” brass Head 3591380049S02204bp 11/4” - 191/2” to 331/4” brass Head 362436
MFR# DesCRIptIon Webb#6857S11009Up Float 24” Tank ID 3591356857S13759Up Float 30” Tank ID 3591346857S14379Up Float 32” Tank ID 3591336857S17009Up Float 37.5” Tank ID 3591326857S18509Up Float 41” Tank ID 361809
MFR# DesCRIptIon Webb#6287-00001k Jr. Support With 4 Floats 359140
DIAl Webb#5909S02733 1840775909S02733 184077
DIAl Webb#5986S02733 1840735986S02733 184073
DIAl Webb#5909S02733 1840775909S02733 184077
DIAl Webb#5909S02733 1840775909S02733 184077
![Page 115: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/115.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ga
ug
es
Gauges
109
6SECTION
6
Gauges6200ApplicationJunior gauges are supplied standard with 0015-00007 Buna-N gasket and four 0040-00414 zinc-plated steel mounting screws (1/4” — 28 X 7/8”) for attachment to a gauge adapter with 2.03” [51,5] diameter bolt circle (see Rochester Machining Standard MS-501). Models 6281 and 6284 Junior gauges used on above ground ASME storage tanks are equipped with direct reading 5323S01749 percentage dials. Model 6281 Junior gauges used on below ground ASME storage tanks are equipped with direct-reading 5323S01813 percentage dials. Models 6241 and 6244 Junior gauges used on ASME motor fuel tanks are equipped with direct-reading 5323S01789 fractional dials.
General SpecificationsTemperature RangeStandard range is -40°F to 158°F, -40°C to 70°C.AccuracyDependent on proper sizing of gauge and tank configuration. When equipped with Jr.™ dial, overall accuracy is ±5%, Sr.™ dial is ±3%, TwinSite™ sender is ±5%, 4” dial is ±3%.HumidityFor high humidity below ground or under chassis applications, brass, stainless steel, or painted aluminum heads are recommended.Shock & VibrationSuitable for mobile service applications.Current200 mA maximum on TwinSite™ versions.System Voltage12 to 24 volts on TwinSite™ versions.Working Pressure375 psi. [25,8 Bar]ApprovalsGauges are UL listed for LP Gas service applications.
When ordering, specify:1. Gauge head size, Jr., Sr., or model #.2. Tank diameter as shown on nameplate.3. Mounting location (top, side, end or angle).4. If gauge is angle mounted, state angle.5. If gauge is end mounted, state the shape of the tank head, hemispherical or
semi-ellipsoidal.6. The “H” dimension, the distance in inches from the surface of the tank to the top of
the gauge opening.To order replacement gauge, simply furnish the information stamped on one of the flat sections on the side of the gauge head as shown in the example.
Model number = 6244Support length = 71/2”Tank Diameter = 14”Mfg date = B75NOTE: Gauge head may also be stamped with model & unique suffix #.
6244 - 71/2”- 14 B75
![Page 116: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/116.jpg)
110 victormfg.com
Gauges 6SECTION
Gas Equipment Catalog
Gauges6300 SeriesApplicationThe 6300 Series Magnetel™ liquid-level gauges are designed to accurately determine the percentage of total tank volume for most liquids in stationary-storage applications. UL listed for LP Gas and NH3 service.
General Information & FeaturesThese Magnetel™ Gauges are available in four basic models:Model 6336 — Incorporates 4” [100 mm] dial and is designed for top mounting.Model 6360 — Incorporates 8” [200 mm] dial and is designed for top mounting.Model 6339 — Incorporates 4” [100 mm] dial and is designed for side, end or angle mounting.Model 6342 — Incorporates an 8” [200 mm] dial and is designed for side, end or angle mounting.The large, easy-to-read dials are also easy to remove and replace. Materials of construction vary depending on the types of liquids to be gauged. Many different optional fea- tures are available to meet your specific needs. These materials and options, along with their pricing impact, are summarized for each model in price list 6300. Magnetel™ gauges are designed for working pressures ranging from atmospheric to 450 [31 Bar] psig.
When ordering, specify:1. Liquid to be gauged and specific gravity.2. Inside diameter of tank, head style: ellipsoidal, semi-ellipsoidal or hemispherical.3. Complete model number desired from price list 6300, (example M6342-11).4. Prefix letters for available options from price list 6300.5. If a dial other than standard is required, furnish drawing and/or details.6. Furnish tank drawings whenever ordering gauges for angle-mounting or for installa- tion in vertical tanks.7. Tank mounting flange, if required (see chart).
NOTE: The dimensions of the threaded neck on this adapter are equivalent to Schedule 80 pipe.
CAUTION: For Lp Gas or NH3 applications requiring 2” NpT connection, specify Y6300 Series Magnetel™ gauges which includes 0022-00525 schedule 80 adapter assembled to gauge.
99/16” [243]Diameter
29/16” [65]From Tank Flange Maximum
Ceramic Pointer Magnet
Alnico Magnet
High and Low Float Arm Stop
140º Float Travel
4.75” [120]2” NPT
3.5”[89]
2.32”[59]
4.75” [120]
2” NPT
3.5”[89]
1.93” [49]
Drawing A
Drawing B
MFR#MAtes WItH tYpe MAteRIAl tHReADs DIMensIons Webb#
0022-00029 6300 Series 21/2” NpTForged Steel 1/2” - 13 UNC-2b
Reference dwg A 275098
0022-00525 Y6300 Series Only 2” NpT sch. 80 Reference dwg b —
![Page 117: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/117.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ga
ug
es
Gauges
111
6SECTION
6
GaugesMagnetel™ Rough Rider™ Liquid-Level GaugesM6300ApplicationThe M6300 series Magnetel™ Rough Rider™ gauges were designed to withstand the vibration and shock inherent in mobile service. Their service life in over-the-road and off-road transports, carrying liquids ranging from LP-gas to crude oil, is unsurpassed. These gauges allow a continuous reading between 5% and 95% of tank contents.
General Information & FeaturesThe Magnetel™ Rough Rider™ gauges are to be installed in the side or end of mobile tanks at the centerline. They are equipped with an exclusive spring controlled shock absorber on the float arm which substantially reduces the stress that quickly destroys conventional gauges. Angle mounting gauges are also available.The M6339 incorporates a 4” [100 mm] dial and the 6342 incorporates an 8” [200 mm] dial. When necessary, the dials are easily replaceable. Refer to price list P6300 for available types, part numbers, etc., as well as other replacement parts and accessories.Price list M6300 includes information on materials of construction, available options, and sales and pricing policy. The Magnetel™ Rough Rider™ gauges are designed for working pressures ranging from atmospheric to 450 [31 Bar] psig.
When ordering, specify:1. Liquid to be gauged and specific gravity.2. Inside diameter of tank heads, ellipsoidal, semi-ellipsoidal or hemispherical.3. Complete model number desired from price list 6300, (example M6342-11).4. Prefix letters for available options from price list 6300.5. If a dial other than standard is required, furnish drawing and/or details.6. Furnish tank drawings whenever ordering gauges for angle-mounting or for installation in vertical tanks.7. If tank mounting flange is required, order separately from chart above.
Drawing AMFR#
MAtes WItH tYpe MAteRIAl tHReADs DIMensIons Webb#
0022-00029 6300 Series 21/2” NpT Forged Steel 1/2” - 13 UNC-2b Reference dwg A —
MFR# DesCRIptIon Webb#CM6339-11-72 Magnetel 72” Diameter Tank-4” Dial 275104CM6339-11-79 Magnetel 79” Diameter Tank-4” Dial 275102
MFR# DesCRIptIon Webb#0015-00019 Gasket-Spiral Wound 2751000022-00029 21/2” MNpT 31/2” bold Flange 2750985137S01262 4” Dial-LpG And NH3 2751250093S00001 4” Dial brackets 2751290040-00413 SS 4” Dial bracket Screws 2751350044-00403 Nut-Magnetel Flange 2751340044-00404 bolt Magnetel Flange 275130
Rough Rider-bobtails
parts and Adapters
![Page 118: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/118.jpg)
112 victormfg.com
Gauges 6SECTION
Gas Equipment Catalog
GaugesThe Eliminator™ Rotogauge Replacement For LP Gas & NH3 ServiceP6293 SeriesApplicationThe Eliminator™ direct-reading float gauge is a direct replacement for 1” NPT rotary-type dip-tube gauges in LP and NH3 storage tanks. These gauges are designed for larger tanks up to 84” [2134mm] in diameter. The Eliminator™ is not intended for use in filling tanks - its use is restricted to tanks with fixed liquid level gauges, used to determine when the maximum fill level has been reached. The eliminator can be used in mobile applications up to 60” [1524mm] in diameter.
How to Do the Conversion1. After the storage tank has been evacuated, remove the rotary gauge from the 1” NPT opening at the centerline of the head. Clean and re-tap the female threads.2. Remove the 2 screws from the bezel. Put the bezel, screws and dial chamber aside for the moment. Remove the 4 mounting screws holding the gauge head to the adapter.3. Insert the lower portion of the replacement gauge, including the float bulb, float arm, gear housing and counterbalance, into the tank opening.4. Apply three wraps of 1/2” [12mm] wide Teflon tape, or other suitable thread sealant, to the 1” NPT threads on the steel adapter through which the gauge support passes.5. Screw the adapter into the tank opening to achieve a leak-tight joint, and align the gauge mounting holes in the horizontal plane.6. Using the gasket and four mounting screws supplied, attach the gauge to the adapter fingertight. Be sure the gauge is right side up, the bracket tab for locating dial chamber should be on the right. Torque the mounting screws evenly to 140/150 lbs.in., [16,4Nm] using a cross pattern.7. Reattach the 4” dial chamber and bezel to the Senior™ gauge head brackets using the two screws supplied.8. If you end up with the dial chamber upside down, you cannot solve the problem by rotating the bracket. You must rotate the entire gauge 180°.
When ordering, specify:1. Model number.2. Tank I.D.3. Shape of the head.Warning: Carefully ensure that gauge and adapter are adequately protected from damage that might cause leakage of tank contents.
Special Order
MFR# MAtes WItH Webb#p6293-R4400 Up to 44” —p6293-R6000 44” - 60” —p6293-R7200 61” - 72” —p6293-R8400 73” - 84” —
![Page 119: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/119.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ga
ug
es
Gauges
113
6SECTION
6
GaugesMagnetic Liquid-Level Gauges for LP Gas Service7200/B7200ApplicationThe 7200 and B7200 Series Junior™ gauges are identical except the former has a zinc die-cast head and the latter has a forged-brass head. Both types have 11/4” Male NPTF threads and 2” [51] hex-wrenching sections and are equipped with direct-reading dials appropriate for the tanks in which they are installed.
General Information & FeaturesModel 7281 and B7281 direct-indicating gauges are for top mounting. When used on above-ground ASME, horizontal, domestic storage tanks, they are equipped with 5323S01749 percentage or 5323S01789 fractional dials. When used on tanks buried underground, they are equipped 5323S01813 percentage dials. Most 420# [190 kg] vertical cylinders utilize the 5323S01835 dial. For dials used on other vertical cylinders, contact Rochester. Model 7284 and B7284 gauges are for side, end or angle mounting. When used on ASME motor-fuel tanks they are equipped with 5323S01789 fractional dial. Please contact Rochester for the part numbers of the various dials used on gauges mounted in lift-truck cylinders.
General SpecificationsTemperature RangeStandard range is -40°F to 158°F, -40°C to 70°C.AccuracyDependent on proper sizing of gauge and tank configuration. With direct reading dials, overall accuracy is ±5%; with TwinSite™ Sender, overall accuracy is ±5%.CurrentTwinSite™ versions, 200 mA. maximumVoltageTwinSite™ versions, 12 and 24 volts.Working Pressure375 psig [25, 8 Bar].ApprovalsGauges are appropriately UL listed for LP Gas liquid-level service and/or LP Gas automotive accessories.
When ordering, specify:1. The tank inside diameter (shown on tank nameplate).2. The mounting location (top, side, end or angle).3. If the gauge is angle mounted, state the degree of angle above or below the horizontal centerline.4. If the gauge is end mounted, state the shape of the tank head (hemispherical or semi-ellipsoidal).5. The “H” dimension. This is the distance in inches from the surface of the tank to the top of the threaded opening.
Typical Gauge
![Page 120: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/120.jpg)
114 victormfg.com
Gauges 6SECTION
Gas Equipment Catalog
Gauges
Is the gauge right for your application?Gauges should only be installed in applications recommended by the manufacturer. Verify that the gauge is the proper gauge for your application prior to attempting installation.The float may or may not have a counterbalance depending on the intended application. Applications for light specific gravity liquids or large tanks normally require counterbalancing of the float.The gauge, mounting gasket and mounting adapter (if applicable) must be constructed of materials compatible with the liquid to be measured and the service environ ment. The float, mounting screws and head must be adequately rated for your specific pressure and temperature service.Is the gauge the proper size?As a general rule, the float pivot point should be on the horizontal centerline of the tank when installed. The float length dimension (measured from the float pivot point to the end of the float) should be proportional to the inside tank height and is usually slightly less than 1/2 of the vertical inside height of the tank.Gauges can be constructed for side, top or angle mounting but must be installed in the position for which they are constructed. Hold the gauge by the support (see Figure A) in the intended mounting attitude and operate the float to see if it is correct for your application (see Figure B).
Jr. & Sr. Gauge InstallationMS-501/502
CAUTION: Improper gauge or dial selection or application may result in inaccurate readings. Release of tank contents as well as damage to equipment and safety hazard may result if tank is overfilled. Fuel exhaustion may occur if tank contents are less than indicated. Lp Gas & NH3 gauge dials require an appropriate temperature chart.WARNING: This gauge is not a substitute for a fixed liquid level gauge or weight measurement device, which may be required for filling.GAUGE REMOVAL WARNING: Should it appear necessary to remove the gauge from the tank, do not attempt removal unless under competent supervision with all due precautions taken against the hazards of released liquid or high pressure and/or flammable gas.HAZARDS: A hazard of fire or explosion may exist if proper methods are not used when removing or installing the gasket. Replace gasket if gauge head is removed. Do not reuse gasket. When reinstalling gauge align head for proper orientation of the float inside tank.
InstallationCheck color stripe on O.D. of gasket for material.BLUE STRIPE= NEOPRENE. Order Senior™ part # 0015-00836 or Junior™ part # 0015-00855 recommended for anhydrous ammonia and specific refrigerant applications.RED STRIPE= BUNA-N. Order Senior™ part # 0015-00004 or Junior™ part # 0015-00007, recommended for specific LP Gas & petroleum applications.BROWN STRIPE = VITON. Order Senior™ part # 0015-00415 or Junior™ part # 0015-00039.WHITE GASKET = TEFLON. Order Senior™ part # 0015-00401 or Junior™ part # 0015-00405.SPIRAL WOUND TEFLON AND STAINLESS STEEL. Order Senior™ part # 0015-00462.
CAUTION: Use spiral wound gasket only with stainless steel gauge head and allen head cap screws.A. Fit gasket onto gauge boss.B. Carefully insert float into adapter or cou- pling and work gauge’s gear housing and support through adapter being careful not to bend or damage them.C. Check to see that gasket is properly sealed in adapter gasket recess.D. Align head for proper orientation of float inside of tank. Torque screws evenly in several steps to the desired torque value. When torquing use a crossing torque pattern.
CAUTION: Do not over torque. Do not re-torque later unless leaking. Over tightening may cause damage to head and gasket.SCREW SIZE DRY TORQUE GASKET TYPE1/4 – 28 20 TO 50 IN.LBS [2,3 to 5,6 Nm] BUNA, NEOPRENE, VITON, TEFLON 5/16 – 24 30 TO 60 IN.LBS [3,4 to 6,8 Nm] BUNA, NEOPRENE, VITON, TEFLON5/16 – 24 140 TO 150 IN.LBS [15,8 to 16,9 Nm] SPIRAL WOUND GASKET
Figure A
Figure b
MS – 502 Sr. Gauges
![Page 121: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/121.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ga
ug
es
Gauges
115
6SECTION
6
Gauges
These instructions are prepared to assist tradesmen and others generally familiar with liquid storage tank equipment. Consumers are not qualified to perform the installation described below. If you have any questions concerning installation or operation of the gauge, contact Rochester Gauges or one of our authorized distributors for assistance. This document is not instructions for tank filling.
MS-516
Figure A
Figure B
An American national standard pipe threads, General purpose (InCH)
ANSI/ASME B1.20.1-1983(Varnish threads due to chamfer on die.)
MFR# tAnK sIZe Webb#6281-15.5-30 320 Gal-30” Diameter 2750996281-19.25-37 500 Gal-37.5” Diameter 2750976281-21-41 1000 Gal-41” Diameter 2750966281-89 200# Vertical 2750956281-85 420# Vertical 184087
Jr. Flange
sr. FlangeMFR# tAnK sIZe Webb#6280-00630 320 Gal-30” Diameter —6280-00637 500 Gal-37.5” Diameter —6280-00641 1000 Gal-41” Diameter —6280-01235 200# Vertical —6280-192 420# Vertical 275101
MFR#tAnK sIZe Webb#
b8981-01232 320 Gal-30” Diameter —
b8981-1237 500 Gal-37.5” Diameter 361808
b8981-1241 1000 Gal-41” Diameter 359343
b8981-01235 200# Vertical —b8981-2009 420# Vertical 275106
1” npt
MFR#tAnK sIZe Webb#
b7281-130 320 Gal-30” Diameter 275114
b7281-137 500 Gal-37.5” Diameter 275112
b7281-141 1000 Gal-41” Diameter 275111
b7281-00388 200# Vertical —b7281-00386 420# Vertical 372633
11/4” npt
DIAl Webb#5909S02733 1840775909S02733 1840775909S02733 1840775909S02772 2751095909S02772 275109
DIAl Webb#5986S02733 1840735986S02733 1840735986S02733 1840735986S02772 2751075986S02772 275107
DIAl Webb#5909S02733 1840775909S02733 1840775909S02733 1840775909S02772 2751095909S02772 275109
DIAl Webb#5909S02733 1840775909S02733 1840775909S02733 1840775909S02772 2751095909S02772 275109
![Page 122: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/122.jpg)
116 victormfg.com
Gauges 6SECTION
Gas Equipment Catalog
Gauges
NOTE: Check color stripe on O.D. of gasket for material.
Senior = 2.06” [52,3] nominal diameter — Junior = 1.56” [39,6] nominal diameterBLUE STRIPE = NEOPRENERED STRIPE = BUNA-NBROWN STRIPE = VITONWHITE GASKET = TEFLONSPIRAL WOUND TEFLON AND STAINLESS STEEL5/16 – 24 screw – 30 to 60 In. Lbs., [3,4 to 6,8 Nm] using a crossing pattern.1/4 – 28 screw – 20 to 50 In. Lbs., [2,3 to 5,6 Nm] using a crossing pattern.#10 screw – 20 to 25 In. Lbs. [2,3 to 2,8 Nm] using a crossing pattern.
Replacing Gaskets115-793
Replacement Dials115-794
Advanced Matrix TwinSite™
Junior™ TwinSite™
Junior™ Direct Reading
MFR# DesCRIptIon Webb#ROG0040-00414 Screw Head, Jr. 184067ROG0040-00415 Screw Head, Sr. 184068 ROG0015-00004 Gasket, Sr. Gauge 184063ROG0015-00007 Gasket, Mounting Jr. 184064 ROG5909S02733 Dial, Jr. W/5-1749 184077ROG5323S01789 Dial, Jr. f/331/2 184098ROG5909S02772 Underground ASME Rep. 275109RbSRS-228 Remote Level Indicator 314605
R3D Dials-Remote Ready
MFR# DesCRIptIon Webb#5909S02733 Jr. ASME Above Ground 1840775909S02799 Jr. ASME Under Ground 2751085986S02733 Sr. AMSE Above Ground 1840735909S02772 Jr. 10-82% Vertical 200/420’S 2751095986S02772 Sr. 10-82% Vertical 200/420’S 2751075987S02787 JY Taylor Style A 2738365988S02788 JY Taylor Style b 2751055988S02889 Jr. Taylor Vertical 420’S Style b 359345
MFR# DesCRIptIon Webb#0015-00004 Sr. Gasket 1840630015-00007 Jr. Gasket 1840640040-00414 Jr. Screw 1840670040-00415 Sr. Screw 1840680040-00675 Jr. Screw For brass Head 372635
screws and Gaskets
MFR# DesCRIptIon Webb#5323S01789 Jr. Fractional 33 1/3# 1840985714S02591 Snap On 33 1/3# 2839675364S01951 Snap On 200/420’s No Remote 1840825AAAS02772 Snap On 200/420’s With Remote 415723
Jr. Dials-Direct Read
![Page 123: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/123.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ga
ug
es
Gauges
117
6SECTION
6
GaugesPressure GaugesMFR# DesCRIptIon Webb#21/2” Dial, 1/4” Brass Lower Mount, ABS CaseASH95449 0-30” w.c. 173954SJIGGAUGE 0-5 pSI 84202 pROp15 0-15 pSI 36483pROp30 0-30 pSI 36484pROp60 0-60 pSI 36485pROp100 0-100 pSI 36486pROp160 0-160 pSI 36487pROp200 0-200 pSI 36488pROp300 0-300 pSI 36489ASH10256 0-30 pSI 36490ASH15039 0-600 pSI 36491ASH14223 0-1000 pSI 3649221/2” Dial, 1/4” Brass Back Mount, ABS CaseASH00165 0-30 pSI 77875ASH00166 0-60 pSI 77876ASH00167 0-100 pSI 77877ASH00168 0-160 pSI 77878ASH00169 0-200 pSI 1765184” Dial, 1/4” Brass Lower Mount, ABS CaseASH12194 0-15 pSI 36496ASH00260 0-30 pSI 36497ASH00261 0-60 pSI 36498ASH00262 0-100 pSI 36499ASH00263 0-160 pSI 36500ASH00264 0-200 pSI 36501ASH14143 0-300 pSI 3650221/2” Liquid Filled Dial, 1/4” Brass Lower Mount, ABS CaseASH00511 0-15 pSI 110914ASH00512 0-30 pSI 110915ASH00513 0-60 pSI 110916ASH00509 0-100 pSI 110917ASH00514 0-160 pSI 110918ASH00515 0-200 pSI 110919ASH00516 0-300 pSI 110920ASH00517 0-400 pSI 110921
![Page 124: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/124.jpg)
118 victormfg.com
Gas Pipe, Tubing & Fittings 7SECTION
Gas Equipment Catalog
Flexible Gas TubingMFR# Size PkG. QTy webb#
Corrugated Stainless Steel 300 Series With Polyethylene JacketTRP-SS4-375-100 3/8” 100’ Reel 216967TRP-SS4-375-250 3/8” 250’ Reel 216966TRPSS4-500-50 1/2” 50’ Reel 250002TRP-SS4-500-100 1/2” 100’ Reel 219618TRP-SS4-500-250 1/2” 250’ Reel 87389TRPSS4-750-50 3/4” 50’ Reel 250003TRP-SS4-750-100 3/4” 100’ Reel 219619TRP-SS4-750-250 3/4” 250’ Reel 87390TRPSS4-100-50 1” 50’ Reel 250001TRP-SS4-100-180 1” 180’ Reel 87391TRPSS4-125-50 11/4” 50’ Reel 250000TRP-SS4-125-150 11/4” 150’ Reel 205453TRP-SS4-150-150 11/2” 150’ Reel 219620TRP-SS4-200-150 2” 150’ Reel 219621
Description/Dimensions
* EHD (Effective Hydraulic Diameter) A relative measure of Flow Capacity. This number is used to compare individual sizes between different manufacturers. The higher the EHD number the greater flow capacity of the piping.
Underground TracPipeMFR# Size PkG. QTy webb#TRPUG375-100 3/8” 100’ Coil 216985TRPUG500-100 1/2” 100’ Coil 216986TRPUG750-100 3/4” 100’ Coil 216987TRPUG100-100 1” 100’ Coil 216988TRPUG125-100 11/4” 100’ Coil 216989TRPUG125-200 11/4” 200’ Coil 241888TRPUG150-100 11/2” 100’ Coil S720800TRPUG150-200 11/2” 200’ Coil 242755TRPUG200-200 2” 200’ Coil 242756
MFR# SS4-375 SS4-500 SS4-750 SS4-100 SS4-125 SS4-150 SS4-200Size (inch) 3/8” 1/2” 3/4” 1” 11/4” 11/2” 2”EDH (AGA Size)* 15 19 25 31 37 46 62Jacket O.D. (max.) .668 .868 1108 1.38 1665 1920 2590Inside Diameter (nom.) .440 .597 820 1.040 1290 1525 2060Wall Thickness (in.) .01 .01 .01 .01 .012 .012 .012
![Page 125: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/125.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ga
s p
ipe, t
ub
ing
& f
itt
ing
sGas Pipe, Tubing & Fittings
119
7SECTION
7
Counterstrike Tubing
MFR# TubinG Size PkG. QTy webb#TRPCS-375-250 3/8” 250’ Reel 368348TRPCS-500-100 1/2” 100’ Reel 368349TRPCS-500-250 1/2” 250’ Reel 368160TRPCS-750-100 3/4” 100’ Reel 368350TRPCS-750-250 3/4” 250’ Reel 368159TRPCS-100-180 1” 180’ Reel 368344TRPCS-125-150 11/4” 150’ Reel 368345TRPCS-150-150 11/2” 150’ Reel 368346TRPCS-200-150 2” 150’ Reel 368347
Installation Bulletin for CounterStrike®
CounterStrike® Installation Instructions for all products date coded 0731 and higher (manufactured after July 30, 2007).
1. CounterStrike CSST with the black, protective sleeve uses the same easy to install AutoFlare® fittings as conventional TracPipe® with the yellow jacket. CounterStrike systems are sized in the same manners as TracPipe either using Capacity Tables or other approved methods.
2. The instructions for cutting the tubing and for making fitting connections to CounterStrike are identical to standard yellow-jacketed TracPipe. The Jacket shall remain intact as much as practical when attaching the fitting.
3. There are no special installation requirements for CounterStrike date coded 0731 and higher. The bonding requirements for CounterStrike are per National Electrical Code NFPA 70 Article 250.104 and the National Fuel Gas Code NFPA 54. No additional bonding is required.
4. CounterStrike date coded 0731 and higher meets building code requirements (ASTM E84) with respect to flame spread and smoke density. This permits installation in drop ceilings used as return air plenums.
5. CounterStrike date coded 0731 and higher has thru penetration UL classifications for 1, 2 and 4 hours with the black jacket intake.
![Page 126: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/126.jpg)
120 victormfg.com
Gas Pipe, Tubing & Fittings 7SECTION
Gas Equipment Catalog
MFR# TyPe Size PkG. QTy webb#TRP-TF500-T500 Tee 1/2” X 1/2” 14/box 260025TRP-TF750-T750 Tee 3/4” X 3/4” 12/box 222079TRP-TF1000T1000 Tee 1” X 1” 10/box 263584TRP-TF750-T500 Tee 1/2” X 3/4” — 222081TRP-TF1000-T500 Tee 1” X 3/4” — 222082TRP-CPLG-375 Coupling 3/8” 24/box 216977TRP-CPLG-500 Coupling 1/2” 24/box 216978TRP-CPLG-750 Coupling 3/4” 16/box 216979TRP-CPLG-1000 Coupling 1” 16/box 216980 Tee Coupling
AutoFlare® FittingsBrass Fitting AutoFlare InsertStraight Mechanical Fittings, Reducing FittingsMFR# TyPe Size PkG. QTy. webb#TRP-FST-375 Straight 3/8” (1/2” NPT) 24/box 216968TRP-FST-500 Straight 1/2” 24/box 87393TRP-FST-750 Straight 3/4” 16/box 87394TRP-RST750-500 Reducing 3/4” - 1/2” NPT 16/box 219624TRP-FST-1000 Straight 1” 16/box 87395TRP-RST1000-750 Reducing 1” - 3/4” NPT 16/box 219625TRP-FST-1250 Straight 11/4” 6/box 205454TRP-FST-1500 Straight 11/2” 4/box 219622TRP-FST-2000 Straight 2” 4/box 219623
Straight Fitting
Reducing Fitting
Termination Mount, Meter TerminationMFR# TyPe PkG. QTy. Size webb#TRP-TM-375 Termination Mount 12/Box 3/8” 217405TRP-TM-500 Termination Mount 12/Box 1/2” 217406TRP-TM-750 Termination Mount 8/Box 3/4” 217407TRP-TM-1000 Termination Mount 8/Box 1” 219626TRP-90TM-375 90° Termination Mount 8/Box 3/8” 217401TRP-90TM-500 90° Termination Mount 8/Box 1/2” 217402TRP-MT6-500 6” Meter Termination 1 ea. 1/2” 246855TRP-MT12-500 12” Meter Termination 1 ea. 1/2” 246856TRPMT6-750 6” Meter Termination 1 ea. 3/4” 250428Flange FittingsTRP-BFF-375 Iron Flange Brass 12/box 3/8” 216975TRP-BFF-500 Iron Flange Brass 12/box 1/2” 87398TRP-BFF-750 Iron Flange Mount Brass 8/box 3/4” 87399TRP-BFF-1000 Iron Flange Mount Brass 8/box 1” 87376TRP-BFF-1250 Iron Flange Mount Brass 4/box 11/4” 216976TRP-TERM-BRAC Flange Bracket 1 ea. All 222077TRP-ELLS-375 90° Elbow Flange Mount 8/box 3/8” 216981TRPFGP-ELLS-500 90° Elbow Flange Mount 8/box 1/2” 216982Grounding ClampsVCTC11N 1/2”, 3/4” 1” 372312VCTC22 11/4” - 2” 372313
Termination Mount
90° Termination Mount
Meter Termination
TracPipe by TracPipe Outlet
Flange Mount Fitting
90° Elbow Flange Mount
Mounting Bracket
MFR# TyPe Size webb#TRPT500-500 Tee 1/2” FIP 222078TRPT750-750 Tee 3/4” FIP 222084TRPT750-500 Tee 3/4” X 1/2” FIP 308740TRPT1000-1000 Tee 1” FIP 222080
TracPipe by Pipe Outlet
TracPipe by Pipe Outlet Tee
![Page 127: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/127.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ga
s p
ipe, t
ub
ing
& f
itt
ing
sGas Pipe, Tubing & Fittings
121
7SECTION
7
Accessories
MFR# DeScRiPTiOn Size PkG. QTy webb#TRPSP-025 Quarter Striker Plate 3” X 2” 500/box 87381TRPSP-050 Half Striker Plate 3” X 7” 100/box 87380TRPSP-100 Full Striker 3” X 12” 50/box 87379TRPFGP-SF-617 Large Plate 61/2” X 17” 276535
Half Striker
Full Striker Plate
Quarter Striker
MFR# DeScRiPTiOn Size PkG. QTy webb#TRPFPY-375 Floppy Fits 3/8” 3/4” 50’ Coil 216969TRPFGP-FPY-500 Floppy Fits 1/2” 1” 50’ Coil 216970TRPFGP-FPY-750 Floppy Fits 3/4” 11/4” 25’ Coil 216971TRPFGP-FPY-1000 Floppy Fits 1” 11/2” 25’ Coil 216972TRPFPY-1250 Floppy Fits 11/4” 2” 25’ Coil 205456TRPFPY-1500 Floppy Fits 2” 21/2” 25’ Coil 216973
Floppy Galvanized Steel conduit
Floppy Strip Wound Conduit
MFR# DeScRiPTiOn Size PkG. QTy webb#TRP-MI-PC Coated Manifold 3/4” X 1/2” X 1/2” (4) 1 ea. 246854TRP-MB2 Manifold Bracket * 1 ea. 217403TRPTERM-BRAC Flange L Bracket * 1 ea. 222077TRPP-LC Load Center With Bracket * 1 ea. 216983TRPFGP-MI-PC-1X Coated Manifold 11/4” X 1” X 3/4” (4) 1 ea. 256174
Manifolds
Coated Manifold
Load CenterWith Bracket
Manifold Bracket
MFR# Size webb#TRPRING-375 3/8” Spare 222083TRPRING-500 1/2” Spare 242572TRPRING-750 3/4” Spare 247210
Spare Split Rings
Striker Plates
MFR# Size webb#TRPHST-12 1/2” 216991TRPHST-34 3/4” 216992TRPHST-1 1” 216993TRPHST-300 11/4” 216994TRPHST-350-6 11/2” 242757TRPHST-2 2” 242758
Shrink cuffs (Two required for each run)
Underground TracPipe AccessoriesVent Tees (Use when required by local codes)MFR# Size webb#TRPVT-125 3/8” and 1/2” 216996TRPVT-150 3/4” and 1” 216997TRPVT-200 11/4” 242759
Shrink Cuffs
Vent Tees
TracPipe Pipe wrapMFR# DeSc. webb#TRP915-10H-12 Yellow Outdoor 242814
Pipe Wrap
TracPipe ToolsMFR# DeSc. webb#TRPTC-151 Tube Cutter for 3/8” – 11/4” 205455TRPTC-152 Tube Cutter for 11/4” – 2” 216984Tube Cutter
![Page 128: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/128.jpg)
122 victormfg.com
Gas Pipe, Tubing & Fittings 7SECTION
Gas Equipment Catalog
Safer installation for GasEasy to Identify• Permanent yellow polyethylene coating.• Continuous line marking.• Traceable back to origin of manufacturing.• Mill test reports available upon request.Easy to Install• No additional training required for installation.• Flexible • Easy to join • Compact size• Requires smaller and fewer tools than steel pipe.• Cleaner than threaded steel pipe.Cost Efficient• Most economical line-marked tubing on the market.• Minimal labor costs due to quick and easy installation.• No on-site sleeving required for underground gas lines.Recyclable• Copper is fully recyclable.
Copper has proven to be reliable and economical source for interior natural gas and liquefied petroleum installations for over 25 years. It’s use has introduced vertical subdivision concepts, individual metering and new add-on markets.Copper’s demand ranges from single-family dwellings to row houses to multi-story apartments. Within these dwellings, gas can be a source for furnaces, room heaters, air conditioning units, gas-fired heating boilers and domestic hot water heaters. Gas also economizes the use of cooking ranges, clothes dryers, gas fireplaces, gas barbeques and decorative gas lamps.
Coated Copper TubingFor Natural Gas and Liquefied Petroleum Gas
Standard Copper Tubing
can Gas-Tec be used underground?Yes, our material can be direct buried. In Canada, Gas-Tec G/Gas is currently the only tubing that can be used both above and below ground without any modification. In the United States, most areas allow Gas-Tec Refrigeration grade or Type “L” tubing to be buried, but we recommend our Gas-Tec type “L” (G/Gas) due to the heavier wall thickness on most sizes.
nOMinal OuTSiDe wall STanDaRDSize DiaMeTeR ThickneSS lenGThS*1/4” L 3/8” G/Gas .030” 30’ 60’ 100’ 250’3/8”L 1/2” G/Gas .035” 30’ 60’ 100’ 250’1/2”L 5/8” G/Gas .040” 30’ 60’ 100’ 250’5/8”L 3/4” G/Gas .042” 30’ 60’ 100’3/4”L 7/8” G/Gas .045” 30’ 60’ 100’
MFR # Size lenGTh webb#reFriGeration tubinG C/T38OD 3/8 50 2582C/T38OD100 3/8 100 58835C/T12OD 1/2 50 2583C/T12OD100 1/2 100 58836C/T58OD 5/8 50 2584C/T58OD100 5/8 100 58837K tubinG C/T38K60 3/8 60 2526C/T38K100 3/8 100 191720C/T12K60 1/2 60 2539C/T12K100 1/2 100 150326C/T58K60 5/8 60 111921L tubinG C/T38L60 3/8 60 2552C/T38L100 3/8 100 190614C/T12L60 1/2 60 2553C/T12L100 1/2 100 91639
OuTSiDe wall STanDaRDDiaMeTeR ThickneSS lenGThS*3/8” .032” 25’ 50’ 100’ 250’1/2” .032” 25’ 50’ 100’ 250’5/8” .035” 25’ 50’ 100’ 250’
* Custom sizes available upon request
MFR# Size webb#General Purpose, Yellow CoatingKMCPC38OD50 3/8” X 50” 190668KMCPC12OD50 1/2” X 50” 190669KMCPC58OD50 5/8” X 50” 190670KMCPC380D100 3/8” X 100” 190671KMCPC120D100 1/2” X 100” 190672KMCPC580D100 5/8” X 100” 190673KMCPC380D250 3/8” X 250” 191023KMCPC120D250 1/2” X 250” 191024KMCPC580D250 5/8” X 250” 245837oil tech, orange CoatingKMC38X50CTD 3/8” X 50” 201445KMC12X50CTD 1/2” X 50” 213315KMC38X100CTD 3/8” X 100” 201446KMC12X100CTD 1/2” X 100” 213316type “L” KMCPC38L60 3/8” X 60” 190674KMCPC12L60 1/2” X 60” 190675KMCPC58L60 5/8” X 60” 190676KMCPC38L100 3/8” X 100” 191820KMCPC12L100 1/2” X 100” 191821
Type l-G/Gas, aSTM b88/b837
General Purpose, aSTM b68/b280 Refrigeration
![Page 129: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/129.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ga
s p
ipe, t
ub
ing
& f
itt
ing
sGas Pipe, Tubing & Fittings
123
7SECTION
7MFR# Size webb#DLKDL6-3 3/8” X 3” 184977DLKDL8-3 1/2” X 3” 184978DLKDL8-6 1/2” X 6” 184979DLKDL12-3 3/4” X 3” 184975DLKDL12-6 3/4” X 6” 184976
MFR# DeScRiPTiOn webb#VCT93UT-08 In-Line Low 361067 Pressure Sediment Trap
Drip Leg Packages
In-Line Trap
MFR# DeSc. webb#HFBLP350X34X1FT 3/4” X 1 FT 438652HFBLP350X34X3FT 3/4” X 3 FT 438653HFBLP350X34X12FT 3/4” X 12 FT 438654HFBLP350X34X18FT 3/4” X 18 FT 438655HFBLP350X34X20FT 3/4” X 20 FT 438656HFBLP350X34X50FT 3/4” X 50 FT 438657HFBLP350X1X15FT 1” X 15 FT 438658HFBLP350X1X100FT 1” X 100FT 438659HFBLP350X1X150FT 1” X 150 FT 438660
Gates Bulk HoseSpiral ReinforcedSeries 7132 LP Gas HoseFeatures a smooth, abrasion resistant cover and the flexibility of the 4 spiral reinforcements result in a hose that is easier to handle and glides smoothly over any surface.• Tube: Black Nitrile.• Cover: Perforated Black Neoprene.• Reinforcement: Multiple Textile Braids.• Temp. Range: -50°F to 180°F.
Certified & Tested
Underground PE Gas PipeMFR# Size webb#YGP12CTS090-75 1/2 CTS X 75’ 378760YGP12CTS090-100 1/2 CTS X 100’ 193140YGP12CTS090-150 1/2 CTS X 150’ 319632YGP12CTS090-200 1/2 CTS X 200’ 193141YGP12CTS090-500 1/2 CTS X 500’ 183524 YGP12SDR93-100 1/2 IPS X 100’ 165738YGP12SDR93-150 1/2 IPS X 150’ 165739YGP12SDR93-200 1/2 IPS X 200’ 165740YGP12SDR93-500 1/2 IPS X 500’ 183399 YGP34SDR11-50 3/4 IPS X 50’ 165571YGP34SDR11-75 3/4 IPS X 75’ 263102YGP34SDR11-100 3/4 IPS X 100’ 165741YGP34SDR11-150 3/4 IPS X 150’ 165742YGP34SDR11-500 3/4 IPS X 500’ 183429 YGP1CTS099-500 1 CTS X 500’ 183525 YGP1SDR11-100 1 IPS X 100’ 165572GP1SDR11-150 1 IPS X 150’ 165743YGP1SDR11-200 1 IPS X 200’ 165744YGP1SDR11-500 1 IPS X 500’ 183430 YGP114SDR11-100 1-1/4 IPS X 100’ 165573YGP114SDR11-150 1-1/4 IPS X 150’ 165745YGP114SDR11-200 1-1/4 IPS X 200’ 165746YGP114SDR11-500 1-1/4 IPS X 500’ 183431 YGP112SDR11-150 1-1/2 IPS X 150’ 165575YGP112SDR11-500 1-1/2 IPS X 500’ 183432 YGP2SDR11-100 2 IPS X 100’ 165749YGP2SDR11-200 2 IPS X 200’ 165751YGP2SDR11-500 2 IPS X 500’ 183433
![Page 130: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/130.jpg)
124 victormfg.com
Gas Pipe, Tubing & Fittings 7SECTION
Gas Equipment Catalog
R.W. Lyall Propane Piping SystemsLower Installation Costs — Fewer Repairs Over Time
Residential application
Lyall provides a wide variety of product sizes and configuration to meet residential needs.
lycOFiT® Mechanical FittingsLYCOFIT® is a mechanical fitting for connecting underground Polyethylene (PE) gas piping systems. Lyall offers over 900 configurations allowing for varied installation requirements.Patented 100% Leak-Proof DesignThe LYCOFIT® fitting takes advantage of the natural sealing properties of the PE pipe, in a superior patented design that uses a barbed spigot to seal the inside diameter (ID) of the PE gas pipe, and a completion sleeve that provides the force necessary for a leak-proof, reliable connection every time. By using the polyethylene as the gasket material, this assures a positive seal between the coupling and the pipe regardless of the outside condition of the pipe. The system eliminates the use of O-rings and rubber gaskets that could leak on scratched pipe or deteriorate under adverse conditions like exposure to chemicals. Compact LYCOFIT® designs allow for installation in confined spaces.
eliminates Pull-OutThe design provides a connection so strong that it provided enough gripping power to eliminate pull-out 100% of the time. In ASTM Quick Burst and Tensile Testing, PE Pipe fails before the LYCOFIT® coupling every time!
instant Visual checkLYCOFIT® provides the installer with a full visual quality check — first “pipe-on” and the “sleeve on” in each installation for a gas tight connection.
The LYCOFIT® connection system by Lyall, which requires no pipe preparation or special training, is much easier and faster to install compared to other mechanical fittings, electrofusion, and thermal fusion methods. Even more important is that installation failures due to bad pipe cuts, poor fusion, and weak connections are eliminated in the process. Add to that the durability of Lyall chemically resistant fittings and you will no longer have to concern yourself with re-installation due to typical joint failures.
• 100% leak-proof, easy to install
• Cost effective, maintenance free joining system
• Unprecedented performance levels and proven reliability
• Excellent durability resistant to harsh chemicals and cracking
• Simple installation, no fusion equipment required
• No measuring or calculating required
• Absolutely no slippage or pull-out
![Page 131: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/131.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ga
s p
ipe, t
ub
ing
& f
itt
ing
sGas Pipe, Tubing & Fittings
125
7SECTION
7
MFR# DeScRiPTiOn webb#Pe Pipe to Copper tube adapter
LYCLC375010B-GCR 3/8” O.D. Flare X 1/2” CTS 179091LYCLC500010B-GCR 1/2” O.D. Flare X 1/2” CTS 179093 Double end Couplings LYCLC010B-DER 1/2” CTS 183448LYCLC030B-DER 1” CTS 179004LYCLC030D-DER 1” CTS 179005LYCLC050W-DER 1/2” IPS 183453LYCLC060Y-DER 3/4” IPS 183449LYCLC070Y-DER 1” IPS 183450LYCLC080X-DESR 11/4” IPS 183451LYCLC090Y-DESR 11/2” IPS 179012LYCLC200Y-DESR 2” IPS 183452 Stop & Go Couplings LYCLC010B-SGR 1/2” CTS 179025LYCLC050W-SGR 1/2” IPS 179027LYCLC060Y-SGR 3/4” IPS 179028 reducer Couplings LYCLC030D010B-RR 1” CTS X 1/2” CTS 179066LYCLC030D060Y-RR 1” CTS X 3/4” IPS 179068LYCLC040B010B-RR 11/4” CTS X 1/2” CTS 179069LYCLC050W010B-RR 1/2” IPS X 1/2” CTS 179073LYCLC060Y010B-RR 3/4” IPS X 1/2” CTS 193507LYCLC060Y050W-RR 3/4” IPS X 1/2” IPS 179074LYCLC070Y010B-RR 1” IPS X 1/2” CTS 179077LYCLC070Y050W-RR 1” IPS X 1/2” IPS 183465LYCLC070Y060Y-RR 1” IPS X 3/4” IPS 179080LYCLC070Y030B-RR 1” IPS X 1” CTS 179081LYCLC080X060Y-RR 11/4” IPS X 3/4” IPS 359260LYCLC090Y060Y-RR 11/2” IPS X 3/4” IPS 359259LYCLC090Y070Y-RR 11/2” IPS X 1” IPS 359261LYCLC200Y070Y-RR 2” IPS X 1” IPS 360328LYCLC200Y080X-RR 2” IPS X 11/4” IPS 179084LYCLC200Y090Y-RR 2” IPS X 11/2” IPS 355654LYCLC200Y060Y-RR 2” IPS X 3/4” IPS 359262 reducing tees LYCLC050W050W010BR 1/2” IPS X 1/2” IPS X 1/2” CTS 202396LYCLC020B020B010BR 3/4” X 3/4” X 1/2” CTS 194154LYCLC070Y070Y10BR 1” X 1” IPS X 1/2” CTS 194161LYCLC070Y070Y60YR 1” X 1” IPS X 3/4” IPS 194164LYCLC080X080X030BR 11/4” X 11/4” IPS X 1” CTS 194169LYCLC060Y060Y010BR 3/4” CTS X 3/4” IPS X 1/2” CTS 202397
R.W. Lyall Propane Piping Systems (continued)
lycOFiT® Mechanical FittingsMFR# DeScRiPTiOn webb#3-Way tee Couplings LYCLC010B-3TR 1/2” CTS 179029LYCLC030B-3TR 1” CTS 179031LYCLC050W-3TR 1/2” IPS 183470LYCLC060Y-3TR 3/4” IPS 183467LYCLC070Y-3TR 1” IPS 179037LYCLC080X-3TR 11/4” IPS 183520LYCLC200Y-3TR 2” IPS 183469 90° elbow Couplings LYCLC050W-ELR 1/2” IPS 183462LYCLC010B-ELR 1/2” CTS 179040LYCLC030B-ELR 1” CTS 179042LYCLC060Y-ELR 3/4” IPS 183458LYCLC070Y-ELR 1” IPS 183459LYCLC080X-ELR 11/4” IPS 183460LC200Y-ELR 2” IPS 183461 repair Couplings LYCLC080X-DER 11/4” IPS 179086LYCLC200Y-DER 2” IPS 179087 end Caps LYCLC010B-ECR 1/2” CTS 179014LYCLC050W-ECR 1/2” IPS 183457LYCLC060Y-ECR 3/4” IPS 179021LYCLC070Y-ECR 1” IPS 183455LYCLC080X-ECR 11/4” IPS 179023LYCLC200Y-ECR 2” IPS 179024 Steel Pipe to Pe Pipe transitions LYCLC050S050W-SPB 1/2” NPT X 1/2” IPS 274130LYCLC060S060YSPB 3/4” NPT X 3/4” IPS 183510LYCLC070S070YSPB 1” NPT X 1” IPS 183511LYCLC080S080XSPB 11/4” NPT X 11/4” IPS 183512LYCLC200S200YSPB 2” NPT X 2” IPS 179062
![Page 132: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/132.jpg)
126 victormfg.com
Gas Pipe, Tubing & Fittings 7SECTION
Gas Equipment Catalog
R.W. Lyall Propane Piping Systems (continued)
lycOFiT® Mechanical Tapping Tees
chamfer Tools
MFR# DeScRiPTiOn webb#Mechanical tapping tees LC080010B-TTR 11/4” IPS X 1/2” CTS 179131LC080030D-TTR 11/4” IPS X 1” CTS 179133LC080070Y-TTR 11/4” IPS X 1” IPS 179143LC200010B-TTR 2” IPS X 1/2” CTS 198639LC200050W-TTR 2” IPS X 1/2” IPS 179154LC200060Y-TT 2” IPS X 3/4” IPS 355653 test Cap, Mechanical tapping teesLCTESTCAP Fits All Lyall Mechanical Tapping Tees
MFR# DeScRiPTiOn webb#LYC0000-33-5647-00 Chamfer Tool 1/2” IPS X 1/2” CT 269235LYC0000-33-5481-00 Chamfer Tool 3/4” IPS X 1/2” CTS 269231LYC0000-33-5516-00 Chamfer Tool 1” IPS X 3/4” IPS 269234LYC0000-33-6580-10 Chamfer Tool 11/4” IPS 371813LYC0000-33-6580-16 Chamfer Tool 11/2” IPS 269646LYC0000-33-6580-17 Chamfer Tool 2” IPS 371809
MFR# DeScRiPTiOn webb#threaded Steel end LYCLT050S010B-BT 1/2” NPT X 1/2” CTS 263208LYCLT050S050W-BT 1/2” NPT X 1/2” IPS 283833LYCLT060S060Y-BT 3/4” NPT X 3/4” IPS 198865LYCLT070S030B-BT 1” NPT X 1” CTS 202405LYCLT070S070Y-BT 1” NPT X 1” IPS 198870LYCLT080S080Y-BT 11/4” NPT X 11/4” IPS SDR11 215554LYCLT090S090Y-BT 11/2” NPT X 11/2” IPS 202399LYCLT200S200Y-BT 2” NPT X 2” IPS 202400
Transition Fittings
Lyall Polyethylene Ball Valvesavailable through special order:Sizes , 1/2” CTS — 2” IPS
Wrench, “t” Handled LYCLCT For Lycofit® Mechanical Tapping Tee Cutter
MFR# DeScRiPTiOn webb#anodeless 90° bend rigid riser LYCSTDLY050010T 1/2” NPT X 1/2” CTS 193302LYCSTDLY060010T 3/4” NPT X 1/2” CTS 192989LYCSTDLY060050T 3/4” NPT X 1/2” IPS 180062LYCSTDLY060060T 3/4” NPT X 3/4” IPS 180063LYCSTDLY070010T 1” NPT X 1/2” CTS 193893LYCSTDLY070030T 1” NPT X 1” CTS 193894LYCSTDLY070050T 1” NPT X 1/2” IPS 193895LYCSTDLY070060T 1” NPT X 3/4” IPS 193896LYCSTDLY070070T 1” NPT X 1” IPS 183406LYCKPLGS080080C-T 11/4” NPT X 11/4” IPS 370409LYCSTDLY090090T 11/2” NPT X 11/2” IPS 193897LYCSTDLY200200T 2” NPT X 2” IPS 193898 anodeless Flexible riser LYCSTDLY060010FXT 3/4” NPT X 1/2” CTS 192494LYCSTDLY060050FXT 3/4” NPT X 1/2” IPS 192628LYCSTDLY060060FXT 3/4” NPT X 3/4” IPS 192630LYCSTDLY070010FXT 1” NPT X 1/2” CTS 192631LYCSTDLY070050FXT 1” NPT X 1/2” IPS 192632LYCSTDLY070060FXT 1” NPT X 3/4” IPS 192634 anodeless LPG Flexible tank risers LYCSTDLY050010FXPGS 1/2” NPT X 1/2” CTS Short 252451LYCSTDLY050050FXPGS 1/2” NPT X 1/2” IPS Short 252452LYCSTDLY060060FXPGL 3/4” NPT X 3/4” NPT Long 252456
MFR# DeScRiPTiOn webb#LYCSHAFC050010B-36 36” 1/2” NPT X 1/2” CTS 261875LYCSHAFC050050W-36 36” 1/2” NPT X 1/2” IPS 261876LYCSHAFC060010B-36 36” 3/4” NPT X 1/2” CTS 261877LYCSHAFC060050W-36 36” 1/2” NPT X 1/2” IPS 261878LYCSHAFC060060Y-36 36” 3/4” NPT X 3/4” IPS 261879LYCSHAFC050010B-48 48” 1/2” NPT X 1/2” CTS 261880LYCSHAFC050050W-48 48” 1/2” NPT X 1/2” IPS 261881LYCSHAFC060010B-48 48” 3/4” NPT X 1/2” CTS 261882LYCSHAFC060050W-48 48” 3/4” NPT X 1/2” IPS 261883LYCSHAFC060060Y-48 48” 3/4” NPT X 3/4” IPS 261884LYCSHAFC050010B-84 84” 1/2” NPT X 1/2” CTS 261885LYCSHAFC050050W-84 84” 1/2” NPT X 1/2” IPS 261886LYCSHAFC060010B-84 84” 3/4” NPT X 1/2” CTS 261887LYCSHAFC060050W-84 84” 3/4” NPT X 1/2” IPS 261888LYCSHAFC060060Y-84 84” 3/4” NPT X 3/4” IPS 261889LYCSHA-CFCY10-SEAL 1/2” CTS Service Head Gasket 269409LYCSHA-CFCY14-SEAL 1/2” IPS Service Head Gasket 269408
lyall Risers
Service head Risers— no coupling Required
![Page 133: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/133.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ga
s p
ipe, t
ub
ing
& f
itt
ing
sGas Pipe, Tubing & Fittings
127
7SECTION
7
R.W. Lyall Propane Piping Systems (continued)
MFR# DeScRiPTiOn webb#Pipe Jaw Vise-Grip 1/2” CTS 183540 3/4” CTS / 1/2” IPS 179097 1” CTS / 3/4” IPS 179098LYCAPJ070 11/4” CTS / 1” IPS 183518LF-BOXQRP Tool Box for QRP-100 179100
accessories for QRP Tool
MFR# DeScRiPTiOn webb#Pipe Clamp Standard – 11/4” IPS 179105 Standard – 11/2” IPS 193027 Standard – 2” IPS 179107LYCAPJ200PB-01 Pull-Back – 2” IPS 179108LYCLF-BOXLAP Tool Box for LAP-100 179109
accessories for laP Tool
Time is moneyTo make sure you do each operation quickly, easily, and properly every time Lyall offers the right tools to assure the job is done correctly.
lycOFiT® installation ToolsTools that make every job quick and easy.LYCOFIT® Tools allow for quick and easy installation of LYCOFIT® fittings. These tools provide perfect alignment and precision installment each and every time, without special training or time consuming measurements required.
Quick Ratchet Press (QRP-100)The QRP-100 is a light weight, durable, single ratchet field assembly tool that installs all LYCOFIT® couplings from 1/2” CTS/IPS through 1” CTS.
MFR# DeScRiPTiOn webb#LYCQRP-100 1/2” CTS — 1” IPS 179095LYCQRP-200 3/4” CTS — 2” IPS 252450
Dual Quick Ratchet Press (QRP-200)Designed for manual installations, the dual ratchet design of the QRP-200 makes it simple to install of medium to large sized piping systems. Installs all LYCOFIT® couplings from 3/4” IPS through 2” IPS.
![Page 134: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/134.jpg)
128 victormfg.com
Gas Pipe, Tubing & Fittings 7SECTION
Gas Equipment Catalog
R.W. Lyall Propane Piping Systems (continued)
Specifications• Meets or exceed all requirements for the Categorization of Mechanical Fittings within
ASTM D2513-90c Category 1, and requirements from the Code of Federal Regulations, Title 49 Part 192.281 and 192.283.
• Meets or exceeds NFPA-58 – 1002, DOT and ISO requirements.• Listed with IAPMO/UPS and CSA• Conforms to the Mechanical Fitting Specification as defined in ASTM F 1924.A complete set of specifications and test results for the product are available upon request.
large auto Press (laP-100)This heavy duty hydraulic tool is designed to provide thousands of worry free installations quickly and easily. Installs 11/4”, 11/2” and 2” IPS LYCOFIT® couplings.
MFR# DeScRiPTiOn webb#Hydraulic tool & enerPaC™ LYCLAP100 11/4” IPS — 2” IPS 183440LYCAHP100 ENERPAC™ 183535LYCHYDPRESS Kit 191819
lycoRing®
Lightweight, disposable plastic ring that easily slips over the PE pipe and securely grips the pipe while inserting the pipe onto the LYCOFIT® spigot. The LycoRing® is included with the matching LYCOFIT® fitting and can be used with all LYCOFIT® configurations that use QRP and LAP tools, including tapping tee outlets. LycoRing® is provided with each LYCOFIT® fitting and eliminates the need for additional gripping tools to install fittings.
![Page 135: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/135.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ga
s p
ipe, t
ub
ing
& f
itt
ing
sGas Pipe, Tubing & Fittings
129
7SECTION
7
![Page 136: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/136.jpg)
130 victormfg.com
Gas Pipe, Tubing & Fittings 7SECTION
Gas Equipment Catalog
The CONSTAB CHAMFER tool is required for all CONSTAB fittings. Other Manufacturere’s tools will not produce a gas-tight connection.
MFR# Size webb#Corrugated Stainless Steel 300 Series With Polyethylene JacketCST0000-33-6580-04 1/2” CTS 371814CST0000-33-6580-12 1/2” IPS 411913CST0000-33-6580-13 3/4” IPS 371810CST0000-33-6580-08 1” CTS 411526CST0000-33-6580-14 1 IPS 371811CST0000-33-6580-10 1-1/4 IPS 371813CST0000-38-6580-16 1-1/2 IPS 269646CST0000-33-6580-17 2 IPS 371809
Chamfer Tools
The internal seal enables each fitting to seal on scratched pipe. A seal is maintained on the smooth inside surface of the polyethylene pipe, regardless of the exterior surface of the piping. This improved seal protection creates the ultimate design for mechanical joints.
Each Con-Stab fitting provides the following unique features:• Two internal seals• Fixed stiffener• Self-locking gripper• Moisture lip• Uni-body construction
The Con-Stab I.D. Seal® fittings provide the user with the following advantages:
• Cost effective joining method• Simple assembly• No additional assembly equipment required for installation ( just chamfer pipe and push)• Expanded product line with various configurations and material options (PE 3408/4710 or PE 2406)• Uni-body design eliminating all external parts• Meets or exceeds all D.O.T., ASTM and NFPA 58 requirements
Continental Industries is an ISO 9001 Certified Company. Continental’s Con-Stab I.D. Seal® product line is manufactured and tested to the following industry standards.
• ASTM D 2513 “Standard Specification for Thermoplastic Gas Pressure Pipe, Tubing and Fittings”• ASME B31.8-1995 “Gas Transmission and Distribution Piping Systems”• D.O.T., Title 49 of the Code of Federal Regulations, Part 192.283 (b)• NFPA 58, LP-Gas Code
![Page 137: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/137.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ga
s p
ipe, t
ub
ing
& f
itt
ing
sGas Pipe, Tubing & Fittings
131
7SECTION
7
Service Head Risers
Risers without Couplings
Risers with Couplings
Couplings
Connection is made above-ground. No tool or fitting is required.
MFR# Size webb#CST1253-92-1004-36 36” 1/2 NPT X 1/2 CTS 261875CST1253-92-1004-84 84” 1/2 NPT X 1/2 CTS 261885CST1253-92-1012-36 36” 1/2 NPT X 1/2 IPS 261876CST1252-92-1012-84 84” 1/2 NPT X 1/2 IPS 261886CST1353-92-1012-36 36” 3/4 NPT X 1/2 IPS 261878CST1353-92-1012-84 84” 3/4 NPT X 1/2 IPS 261888CST1353-92-1013-36 36” 3/4 NPT X 3/4 IPS 261879CST1353-92-1013-84 84” 3/4 NPT X 3/4 IPS 261889
MFR# Size webb#CST1253-91-4604-00 1/2 NPT X 1/2 CTS 193302CST1353-91-4604-00 3/4 NPT X 1/2 CTS 192989CST1353-91-4612-00 3/4 NPT X1 /2 IPS 180062CST1353-91-4613-00 3/4 NPT X 3/4 IPS 180063CST1453-91-4614-00 1 NPT X 1 IPS 183406CST1553-91-4615-0A 1-1/4 NPT X 1-1/4 IPS 414143CST1652-91-4616-00 1-1/2 NPT X 1-1/2 IPS 193897CST1752-91-4617-00 2 NPT X 2 IPS 193898
MFR# Size webb#CST1253-91-4604-25 1/2 NPT X 1/2 CTS 411528CST1353-91-4604-25 3/4 NPT X 1/2 CTS 411530CST1353-91-4612-25 3/4 NPT X 1/2 IPS 411533CST1353-91-4613-25 3/4 NPT X 3/4 IPS 411534CST1453-91-4614-25 1 NPT X 1 IPS 411542CST9953-99-0503-25 1-1/4 NPT X 1-1/4 IPS 411589CST1652-91-4616-25 1-1/2 NPT X 1-1/2 IPS 411547CST1752-91-4617-25 2 NPT X 2 IPS 411548
MFR# Size webb#CST3259-52-1004-00 1/2 CTS 269237CST3259-52-1012-00 1/2 IPS 269238CST3259-52-1013-00 3/4 IPS 269239CST3259-52-1008-00 1 CTS 370557CST3259-52-1014-00 1 IPS 269289CST3259-52-1015-AA 1-1/4 IPS 269240CST3259-52-1016-00 1-1/2 IPS 269645CST3259-52-1017-00 2 IPS 269241
![Page 138: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/138.jpg)
132 victormfg.com
Gas Pipe, Tubing & Fittings 7SECTION
Gas Equipment Catalog
Reducing Couplings
Repair Couplings
Tees
Reducing Tees
90° Elbows
MFR # Size webb#CST3259-54-1204-00 1/2 IPS X 1/2 CTS 269251CST3259-54-1304-00 3/4 IPS X 1/2 CTS 269252CST3259-54-1404-00 1 IPS X 1/2 CTS 269254CST3259-54-1312-00 3/4 IPS X 1/2 IPS 269253CST3259-54-1413-00 1 IPS X 3/4 IPS 269255CST3259-54-1513-0A 1-1/4 IPS X 3/4 IPS 413038CST3259-54-1514-00 1-1/4 IPS X 1 IPS 269257CST3259-54-1615-0A 1-1/2 IPS X 1-1/4 IPS 269644
MFR# Size webb#CST3238-14-4415-AA 1-1/4 IPS 371843CST3238-14-4417-00 2 IPS 269267
MFR# Size webb#CST3259-50-1004-00 1/2 CTS 269212CST3259-50-1012-00 1/2 IPS 269213CST3259-50-1013-00 3/4 IPS 269214CST3259-50-1008-00 1 CTS 370558CST3259-50-1014-00 1 IPS 269215CST3259-50-1015-AA 1-1/4 IPS 370556CST3259-50-1016-00 1-1/2 IPS 269648CST3259-50-1017-00 2 IPS 269217
MFR# Size webb#CST3259-49-1304-00 3/4 IPS X 1/2 CTS 269259CST3259-49-1404-00 1 IPS X 1/2 CTS 269260CST3259-49-1413-00 1 IPS X 3/4 IPS 269261CST3259-49-1715-0A 2 IPS X 1-1/4 IPS 269262
MFR# Size webb#CST3259-51-1004-00 1/2 CTS 269218CST3259-51-1012-00 1/2 IPS 269219CST3259-51-1013-00 3/4 IPS 269220CST3259-51-1008-00 1 CTS 370559CST3259-51-1014-00 1 IPS 269221CST3259-51-1015-AA 1-1/4 IPS 370554CST3259-51-1016-00 1-1/2 IPS 269647CST3259-51-1017-00 2 IPS 269223
![Page 139: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/139.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ga
s p
ipe, t
ub
ing
& f
itt
ing
sGas Pipe, Tubing & Fittings
133
7SECTION
7
Cap-N-Go Fittings
Cap End
Pex Copper Transition Couplings
MFR# Size webb#CST3259-57-1004-00 1/2 CTS 269224CST3259-57-1013-00 3/4 IPS 269225CST3259-57-1015-0A 1-1/4 IPS 269226CST3259-57-1017-00 2 IPS 269227
MFR# Size webb#269242 CST3259-53-1004-00 1/2 CtS269243 CST3259-53-1013-00 3/4 iPS269244 CST3259-53-1014-00 1 iPS370555 CST3259-53-1015-0A 1-1/4 iPS269246 CST3259-53-1017-00 2 iPS
MFR# Size webb#CST9943-99-0064-00 1/2 PE X 1/2 OD COPPER 269249CST9943-99-0065-00 1/2 PE X 5/8 OD COPPER 269250
Underground Gas Line MarkersMFR# DeScRiPTiOn webb#MISUD21 TAPE UNDERGROUND GAS 31-140 183516VCTTRACERWIRE TRACER WIRE 500’ 14A 359306ELE1207PE30-YE Tracer Wire 500’ 12A 243218
Anode Bags - 17 lbsMFR# DeScRiPTiOn webb#CPRANODE17 ANODE MAGNESIUM BAGS 183403
![Page 140: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/140.jpg)
134 victormfg.com
connectors 7SECTION
Gas Equipment Catalog
Stainless Steel Gas ConnectorsResidential Stainless Steel Gas Appliance ConnectorsDormont’s complete line of flexible, corrugated, Supr-Safe® stainless steel connectors attach all types of gas appliances to gas utility lines. . .easily and safely. We carry the largest inventory in the business, with connectors ranging from 3/8” through 11/2” O.D.
MFR# OD iD lenGTh ThReaD TyPe webb#Water Heater, Gas Log, Space Heater, Connectors With FittingsDOR10-2121-12 3/8” 1/4” 12” 3/8 mnpt end 242096DOR10-2121-18 3/8” 1/4” 18” 3/8 mnpt end 202067DOR10-2121-24 3/8” 1/4” 24” 3/8 mnpt end 185424DOR10-2121-30 3/8” 1/4” 30” 3/8 mnpt end 246859DOR10-2121-36 3/8” 1/4” 36” 3/8 mnpt end 244976DOR10-2121-48 3/8” 1/4” 48” 3/8 mnpt end 246858DOR10-2222-12 3/8” 1/4” 12” 3/8 fnpt end 185448DOR10-2222-18 3/8” 1/4” 18” 3/8 fnpt end 188283DOR10-2222-24 3/8” 1/4” 24” 3/8 fnpt end 215474DOR10-2222-36 3/8” 1/4” 36” 3/8 fnpt end 213164DOR10-2222-48 3/8” 1/4” 48” 3/8 fnpt end 245962DOR10-3131-18 3/8” 1/4” 18” 1/2 mnpt end 209723DOR10-3131-36 3/8” 1/4” 36” 1/2 mnpt end 209724Dryer Connections With FittingsDOR20-2122-18 1/2” 3/8” 18” 3/8 mnpt/fnpt 163856DOR20-2122-30 1/2” 3/8” 30” 3/8 mnpt/fnpt 163857DOR20-2222-36 1/2” 3/8” 36” 3/8 fnpt 192747DOR20-2222-48 1/2” 3/8” 48” 3/8 fnpt 206103DOR20-3122-12 1/2” 3/8” 12” 1/2 mnpt–3/8 fnpt 191054DOR20-3122-18 1/2” 3/8” 18” 1/2 mnpt–3/8 fnpt 192608DOR20-3122-24 1/2” 3/8” 24” 1/2 mnpt–3/8 fnpt 191055DOR20-3122-36 1/2” 3/8” 36” 1/2 mnpt–3/8 fnpt 192613DOR20-3122-48 1/2” 3/8” 48” 1/2 mnpt–3/8 fnpt 192610DOR20-3122-60 1/2” 3/8” 60” 1/2 mnpt–3/8 fnpt 192611DOR20-3122-72 1/2” 3/8” 72” 1/2 mnpt–3/8 fnpt 191056DOR20-3131-12 1/2” 3/8” 12” 1/2 mnpt 166786DOR20-3131-18 1/2” 3/8” 18” 1/2 mnpt 209421DOR20-3131-24 1/2” 3/8” 24” 1/2 mnpt 166228DOR20-3131-36 1/2” 3/8” 36” 1/2 mnpt 209422DOR20-3131-48 1/2” 3/8” 48” 1/2 mnpt 166229DOR20-3131-60 1/2” 3/8” 60” 1/2 mnpt 209423DOR20-3132-36 1/2” 3/8” 36” 1/2 mnpt–1/2 fnpt 215815DOR20-3132-48 1/2” 3/8” 48” 1/2 mnpt–1/2 fnpt 224158range Connectors With FittingsDOR30-3131-12 5/8” 1/2” 12” 1/2 mnpt 245963DOR30-3131-18 5/8” 1/2” 18” 1/2 mnpt 218889DOR30-3131-24 5/8” 1/2” 24” 1/2 mnpt 193511DOR30-3131-30 5/8” 1/2” 30” 1/2 mnpt 201236DOR30-3131-36 5/8” 1/2” 36” 1/2 mnpt 79589DOR30-3131-48 5/8” 1/2” 48” 1/2 mnpt 179822DOR30-3131-60 5/8” 1/2” 60” 1/2 mnpt 212867DOR30-3131-72 5/8” 1/2” 72” 1/2 mnpt 218890DOR30-3132-24 5/8” 1/2” 24” 1/2 mnpt–1/2 fnpt 204534DOR30-3132-30 5/8” 1/2” 30” 1/2 mnpt–1/2 fnpt 163854DOR30-3132-48 5/8” 1/2” 48” 1/2 mnpt–1/2 fnpt 163855DOR30-3232-12 5/8” 1/2” 12” 1/2 fnpt 185449DOR30-3232-18 5/8” 1/2” 18” 1/2 fnpt 68547DOR30-3232-24 5/8” 1/2” 24” 1/2 fnpt 68548DOR30-3232-36 5/8” 1/2” 36” 1/2 fnpt 68549DOR30-3232-48 5/8” 1/2” 48” 1/2 fnpt 68692DOR30-3232-60 5/8” 1/2” 60” 1/2 fnpt 185458DOR30-3232-72 5/8” 1/2” 72” 1/2 fnpt 185460
![Page 141: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/141.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ga
s p
ipe, t
ub
ing
& f
itt
ing
sconnectors
135
7SECTION
7
MFR# OD iD lenGTh ThReaD TyPe webb#range Connectors With end FittingsDOR30-4141-18 5/8” 1/2” 18” 3/4 mnpt 213943DOR30-4141-24 5/8” 1/2” 24” 3/4 mnpt 213944DOR30-4141-36 5/8” 1/2” 36” 3/4 mnpt 197947DOR30-4144-18 5/8” 1/2” 18” 3/4 mnpt–3/4” mnpt 90 67650DOR30-4144-24 5/8” 1/2” 24” 3/4 mnpt–3/4” mnpt 90 55306DOR30-4144-36 5/8” 1/2” 36” 3/4 mnpt–3/4” mnpt 90 67651DOR30-4144-48 5/8” 1/2” 48” 3/4 mnpt–3/4” mnpt 90 67653DOR30-4242-18 5/8” 1/2” 18” 3/4 fnpt 55305DOR30-4242-24 5/8” 1/2” 24” 3/4 fnpt 67652DOR30-4242-36 5/8” 1/2” 36” 3/4 fnpt 55307DOR30-4242-48 5/8” 1/2” 48” 3/4 fnpt 55308DOR30-4242-60 5/8” 1/2” 60” 3/4 fnpt 185457DOR30-4242-72 5/8” 1/2” 72” 3/4 fnpt 185459DOR40-4142-24 1” 3/4” 24” 3/4 mnpt–3/4 fnpt 184568
Stainless Steel Gas Connectors (continued)
MFR# DeScRiPTiOn webb# Dryer 20 Series (Fittings for 1/2” oD Connectors)DOR90-2032 1/2” fnpt For 1/2” OD (3/8” ID) 246634DOR90-2042 3/4” fnpt For 1/2” OD (3/8” ID) 179505Dryer 30 Series (Fittings for 5/8” oD Connectors)DOR90-3031 1/2” mnpt For 5/8” OD (1/2” ID) 185463DOR90-3041 3/4” mnpt For 5/8” OD (1/2” ID) 209028DOR90-3032 1/2” fnpt For 5/8” OD (1/2” ID) 185462DOR90-3042 3/4” fnpt For 5/8” OD (1/2” ID) 185461
end Fittings
MFR# OD iD lenGTh ThReaD TyPe webb# DOR10A-2121-12 3/8” 1/4” 12” 3/8 mnpt end 308566 DOR10A-212-18 3/8” 1/4” 18” 3/8 mnpt end 308567 DOR10A-2121-24 3/8” 1/4” 24” 3/8 mnpt end 308568 DOR10A-3131-12 3/8” 1/4” 12” 1/2 mnpt end 308576 DOR10A-3131-18 3/8” 1/4” 18” 1/2 mnpt end 308577 DOR10A3131-24 3/8” 1/4” 24” 1/2 mnpt end 308578 DOR10A-3131-30 3/8” 1/4” 30” 1/2 mnpt end 308579
low Visibility hearth connectors black
connector Flow capacity (Per anSi z21.24)
SeRieS
nOMinal cOnnecTOR
iD, inch
STRaiGhT lenGTh caPaciTy – bTu PeR hR (w) 0.64 SP. GR.1000 bTu PeR cu FT. (37.2 MJ/M3) GaS aT 0.5 inch waTeR cOluMn
(124 Pa) PReSSuRe DROP1 FOOT (0.30 M)
11/2 FOOT(0.48 M)
2 FOOT(0.61 M)
21/2 FOOT(0.76 M)
3 FOOT(0.91 M)
4 FOOT(1.22 M)
5 FOOT(1.52 M)
6 FOOT (1.83 M)
10 1/4” 48000 (14 067)
43800(12 837)
400000(11 723)
36400(10 668)
33400(9 789)
28300(8 294)
24900(7 297)
23100(6 770)
20 3/8” 102000(29 893)
93100(27 285)
85000(24 911)
77100(22 742)
71100(20 837)
60500(17 731)
53200(15 591)
49100(14 390)
30 1/2” 180000(52 811)
164200(48 122)
150000(43 961)
136000(40 034)
125000(36 634)
106000(31 066)
93200(27 314)
86000(25 380)
![Page 142: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/142.jpg)
136 victormfg.com
connectors 7SECTION
Gas Equipment Catalog
MFR# DeScRiPTiOn webb#1/2” Quick CouplingsDOR1650BPQ36 1/2” X 36” 213236DOR1650BPQ48 1/2” X 48” 185437DOR1650BPQ60 1/2” X 60” 1854393/4” Quick CouplingsDOR1675BPQ36 3/4” X 36” 185435DOR1675BPQ48 3/4” X 48” 185436DOR1675BPQ60 3/4” X 60” 1854381” Quick CouplingsDOR16100BPQ24 1” X 24” 216370DOR16100BPQ36 1” X 36” 216371DOR16100BPQ48 1” X 48” 2040503/4” Quick Coupling with restraining Device*DOR1675BPQR36 3/4” X 36” 163870restraining Device CoilsDORRDC-36 For 36” Commercial Flex 163862DORRDC-48 For 48” Commercial Flex 163863SnapFast™ ConnectorsDORA50 1/2” Snap Fast Connector 163860DORA75 3/4” Snap Fast Connector 163861
commercial Supr-Safe® Disconnect Gas appliance connectors – bPQ SeriesStainless Steel corrugated hose, encased in a stainless steel braid, covered with a thick Super-Flex coating and fitted with an A Type “Push-to-Connect” quick disconnect coupling.
Dormont Moveable Connector with Push-to-Connect Quick Disconnect.
bTu Flow capacitiesGas connectors for Moveable equipment
Gas connectors for Moveable equipment with Safety Quik and Supr-Swivel Fittings
* Also available as kit with restraining device, special order.
CSA International design certifies gas connectors for a maximum operating pressure of 0.5 psig. Capacities shown, which exceed minimum ANSI requirements, are results from independent testing laboratories. Minimum required BTU capacities for gas connectors (B & BP models) are defined by ANSI Z21.69. Flow capacities for connector assemblies exclude manual shut-off valves. BTU capacities decrease when the length of the connector increase. Flow rating BTU 0.64 SP.GR at 0.5 W.C. pressure drop.
Stainless Steel Gas Connectors (continued)
MFR#
lenGThinSiDe
Dia. 12” 24” 36” 48” 60” 72”1650B, 1650BP 1/2” 15,2000 150,000 120,000 106,000 93,000 87,0001650BQ, BPQ, BPQB, BPCF 1/2” 98,000 870,00 77,000 68,000 60,000 55,0001675B, 1675BP 3/4” 326,000 291,000 256,000 225,000 198,000 175,0001675BQ, BPQ, BPQB, BPCF 3/4” 260,000 232,000 218,000 180,000 158,000 139,00016100B, 16100BP 1” 652,000 582,000 512,000 451,000 397,000 350,00016100BQ, BPQ, BPQB, BPCF 1” 425,000 414,000 379,000 334,000 294,000 279,00016125B, 16125BP 11/4” 1,204,000 1,075,000 946,000 833,000 733,000 645,00016125BQ, BPQ 11/4” 783,000 699,000 615,000 541,000 476,000 419,000
MFR#
lenGThinSiDe
Dia. 12” 24” 36” 48” 60” 72”1650BPQS, BPCFS 1/2” 92,000 81,000 72,000 63,000 56,000 51,0001650BPQ2S, BPCF2S 1/2” 88,000 77,000 69,000 60,000 54,000 48,0001675BPQS, BPCFS 3/4” 242,000 216,000 203,000 167,000 147,000 130,0001675BPQ2S, BPCF2S 3/4” 230,000 205,000 193,000 160,000 140,000 124,00016100BPQS, BPCFS 1” 396,000 385,000 353,000 310,000 274,000 260,00016100BPQ2S, BPCF2S 1” 377,000 366,000 336,000 295,000 261,000 247,000
![Page 143: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/143.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ga
s p
ipe, t
ub
ing
& f
itt
ing
sFittings
137
7SECTION
7
Brass Flare Fittings
#42R Flare X Flare Reducing unionMFR# cODe Size webb#
UR2-64 SAE38X14UN 3/8 X 1/4 30291UR2-86 SAE12X38UN 1/2 X 3/8 34574UR2-108 SAE58X12UN 5/8 X 1/2 34820UR2-84 SAE12X14UN 1/2 X 1/4 34818UR2-106 SAE58X38UN 5/8 X 3/8 34819UR2-128 SAE34X12UN 3/4 X 1/2 19792
#42 Flare X Flare unionMFR# cODe Size webb#
U2-2 SAE18UN 1/8 19795U2-3 SAE316UN 3/16 19796U2-4 SAE14UN 1/4 19797U2-5 SAE516UN 5/16 19798U2-6 SAE38UN 3/8 19799U2-8 SAE12UN 1/2 19801U2-10 SAE58UN 5/8 19802U2-12 SAEU2-12 3/4 19803U2-14 SAE78UN 7/8 19804
#46 Flare X Female (FPT) unionMFR# cODe Size webb#
U3-3A SAE316ODX18FA 3/16 X 1/8 19747U3-4A SAE14ODX18FA 1/4 X 1/8 19748U3-4B SAE14ODXFA 1/4 X 1/4 19749U3-6A SAE38ODX18FA 3/8 X 1/8 19754U3-6B SAE38ODX14FA 3/8 X 1/4 19755U3-6C SAE38ODXFA 3/8 X 3/8 19756U3-6D SAE38ODX12FA 3/8 X 1/2 19757U3-6E SAE38ODX34FA 3/8 X 3/4 19758U3-8B SAE12ODX14FA 1/2 X 1/4 19759U3-8C SAE12ODX38FA 1/2 X 3/8 19760U3-8D SAE12ODXFA 1/2 X 1/2 19761U3-8E SAE12ODX34FA 1/2 X 3/4 19762U3-10C SAE58ODX38FA 5/8 X 3/8 19763U3-10D SAE58ODX12FA 5/8 X 1/2 19764U3-10E SAE58ODX34FA 5/8 X 3/4 19765U3-12E SAE34ODX34FA 3/4 X 3/4 19767
MFR# cODe Size webb# U1-2A SAE18MUN 1/8 X 1/8 19769U1-3A SAE316X18MUN 3/16 X 1/8 19770 SAE316X14MUN 3/16 X 1/4 19771U1-4A SAE14X18MUN 1/4 X 1/8 19772U1-4B SAE14MUN 1/4 X 1/4 19773U1-4C SAE14X38MUN 1/4 X 3/8 19774U1-4D SAE14X12MUN 1/4 X 1/2 19775U1-5A SAE516X18MUN 5/16 X 1/8 19776U1-5B SAE516X14MUN 5/16 X 1/4 19777U1-5C SAE516X38MUN 5/16 X 3/8 19778U1-6A SAE38X18MUN 3/8 X 1/8 19779U1-6B SAE38X14MUN 3/8 X 1/4 19780U1-6C SAE38X38MUN 3/8 X 3/8 19781U1-6D SAE38X12MUN 3/8 X 1/2 19782U1-6E SAE38X34MUN 3/8 X 3/4 19783U1-8B SAE12X14MUN 1/2 X 1/4 19784U1-8C SAE12X38MUN 1/2 X 3/8 19785U1-8D SAE12X12MUN 1/2 X 1/2 19786U1-8E SAE12X34MUN 1/2 X 3/4 19787U1-10B SAE58X14MUN 5/8 X 1/4 19788U1-10C SAE58X38MUN 5/8 X 3/8 19789U1-10D SAE58X12MUN 5/8 X 1/2 19790U1-10E SAE58X34MUN 5/8 X 3/4 19791U1-12D SAE34X12MUN 3/4 X 1/2 368566U1-12E SAE34ODX34MUN 3/4 X 3/4 19793U1-14E SAE78X34MUN 7/8 X 3/4 19794 SAE38X38MUNLNG 3/8 X 3/8 361612 SAE38X12MUNLNG 3/8 X 1/2 361613 SAE12X12MUNLNG 1/2 X 1/2 361614 SAE58X12MUNLNG 5/8 X 1/2 361615
#48 Flare X Male (MPT) union
#114 Swivel nut Female Flare X Female FlareMFR# cODe Size webb#
US4-4 SAE14SWIVELNUT 1/4 78995US4-6 SAE38SWIVELNUT 3/8 77598US4-8 SAE12SWIVELNUT 1/2 77599US4-10 SAE58SWIVELNUT 5/8 78996US4-86 SAE12X38SWIVELNUT 1/2 X 3/8 95739US4-108 SAE58X12SWIVELNUT 5/8 X 1/2 95738
#447 Flare Plug Male FlareMFR# cODe Size webb#P2-4 SAE14PL 1/4 19742P2-6 SAE38PL 3/8 19744P2-8 SAE12PL 1/2 19745P2-10 SAE58PL 5/8 19746
#446 Flare cap Female FlareMFR# cODe Size webb#N5-3 SAE316CAP 3/16 19735N5-4 SAE14CA 1/4 19736N5-5 SAE516CAP 5/16 19737N5-6 SAE38CA 3/8 19738N5-8 SAE12CA 1/2 19739N5-10 SAE58CAP 5/8 19740
#461 Flare bonnetsMFR# cODe Size webb#B1-4 SAE461-4 1/4 185393B1-6 SAE38BONNET 3/8 185395B1-8 SAE12BONNET 1/2 185396B1-10 SAE461-10 5/8 185391
LONG
![Page 144: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/144.jpg)
138 victormfg.com
Fittings 7SECTION
Gas Equipment Catalog
Brass Flare Fittings
MFR# cODe Size webb#E1-2A SAE18M90 1/8 19823E1-3A SAE316X18M90 3/16 X 1/8 19824E1-3B SAE316X14M90 3/16 X 1/4 19825E1-4A SAE14X18M90 1/4 X 1/8 19826E1-4B SAE14M90 1/4 19827E1-4C SAE14X38M90 1/4 X 3/8 19828E1-4D SAE14ODX12M90 1/4 X 1/2 19829E1-5A SAE516X18M90 5/16 X 1/8 19830E1-5B SAE516X14M90 5/16 X 1/4 19831E1-5C SAE516X38M90 5/16 X 3/8 19832E1-6A SAE38X18M90 3/8 X 1/8 19833E1-6B SAE38X14M90 3/8 X 1/4 19834E1-6C SAE38X38M90 3/8 X 3/8 19835E1-6D SAE38X12M90 3/8 X 1/2 19836E1-6E SAE38ODX34M90 3/8 X 3/4 19837E1-8B SAE12X14M90 1/2 X 1/4 19838E1-8C SAE12X38M90 1/2 X 3/8 19839E1-8D SAE12X12M90 1/2 X 1/2 19840E1-8E SAE12ODX34M90 1/2 X 3/4 19841E1-10C SAE58X38M90 5/8 X 3/8 19843E1-10D SAE58ODX12M90 5/8 X 1/2 19844E1-10E SAE58ODX34M90 5/8 X 3/4 19845E1-12D SAE34ODX12M90 3/4 X 1/2 19846
#49 Flare X Male (MPT) elbow
#564 Flare X Female (FPT) elbowMFR# cODe Size webb#E3-6C SAE38ODX38F90 3/8 X 3/8 19813E3-6D SAE38ODX12F90 3/8 X 1/2 19814E3-8D SAE12ODX12F90 1/2 X 1/2 19818E3-8E SAE12ODX34F90 1/2 X 3/4 19819E3-10C SAE58ODX38F90 5/8 X 3/8 19820E3-10D SAE58ODX12F90 5/8 X 1/2 19821E3-10E SAE58ODX34F90 5/8 X 3/4 19822
#481 Forged Flare nutMFR# cODe Size webb#NS4-4 SAE14RNUT 1/4 34570NS4-6 SAE38RNUT 3/8 34571NS4-8 SAE12RNUT 1/2 34572NS4-10 SAE58RNUT 5/8 34814NSR4-86 SAE12X38RNUT 1/2 X 3/8 215886NSR4-108 SAE58X12RNUT 5/8 X 1/2 215887
#45 Flare X Flare X Male (MPT) TeeMFR# cODe Size webb# T1-6C SAE38ODX38MT2 3/8 X 3/8 19872T1-8D SAE12ODX12MT2 1/2 X 1/2 19875T1-6B SAE38ODX14MT5 3/8 X 1/4 19883T1-10D SAE58ODX12MT5 5/8 X 1/2 19888
#44R Flare X Flare X Flare Reducing TeeMFR# cODe Size webb#TR2-664 SAE38X14T 3/8 X 1/4 34826TR3-668 SAE38X12T 3/8 X 1/2 34827TR2-886 SAE12X38T 1/2 X 3/8 34833TR2-10106 SAE58X38T 5/8 X 3/8 34838TR2-10808 SAE58X12T 5/8 X 1/2 34839TR2-10810 SAE58X12X58T 5/8 X 1/2 X 5/8 191825TR2-868 SAE12X38X12T 1/2 X 3/8 X 1/2 192879TR2-8810 SAE12X58T 1/2 X 5/8 192880
#44 Flare X Flare X Flare TeeMFR# cODe Size webb# T2-2 SAE18T 1/8 19856 T2-3 SAE316T 3/16 19857 T2-4 SAE14T 1/4 19858 T2-5 SAE516T 5/16 19859 T2-6 SAE38T 3/8 19860 T2-8 SAE12T 1/2 19861 T2-10 SAE58T 5/8 19862 T2-12 SAE34T 3/4 19863
#55 Flare X Flare elbowMFR# cODe Size webb#E2-2 SAE1890 1/8 19847E2-3 SAE31690 3/16 19848E2-4 SAE1490 1/4 19849E2-5 SAE51690 5/16 19850E2-6 SAE3890 3/8 19851E2-8 SAE1290 1/2 19852E2-10 SAE5890 5/8 19853E2-12 SAE3490 3/4 19854ER2-64 SAE38X1490 3/8 X 1/4 34823ER2-86 SAE12X3890 1/2 X 3/8 34824ER2-106 SAE58X3890 5/8 X 3/8 94502ER2-108 SAE58X1290 5/8 X 1/2 94503
![Page 145: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/145.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ga
s p
ipe, t
ub
ing
& f
itt
ing
sFittings
139
7SECTION
7
Propane Hose & Fittingshose barb to Male Pipe Fitting
MFR# DeScRiPTiOn webb#SAE14Hx18M 1/4” I.D. Hose X 1/8” MPT 19964SAE14Hx14M 1/4” I.D. Hose X 1/4” MPT 19965SAE14Hx38M 1/4” I.D. Hose X 3/8” MPT 19966SAE38Hx18M 3/8” I.D. Hose X 1/8” MPT 19969SAE38Hx14M 3/8” I.D. Hose X 1/4” MPT 19970SAE38Hx38M 3/8” I.D. Hose X 3/8” MPT 19971SAE38Hx12M 3/8” I.D. Hose X 1/2” MPT 19972
hose barb to Female Flare Swivel
MFR# DeScRiPTiOn webb#SAE14Hx38FFL 1/4” I.D. Hose X 3/8” Female Flare Swivel 110988SAE38Hx38FFL 3/8” I.D. Hose X 3/8” Female Flare Swivel 184985SAE38Hx12FFL 3/8” I.D. Hose X 1/2” Female Flare Swivel 223454
hose barb to Male Flare
MFR# DeScRiPTiOn webb#SAE14Hx38MFL 1/4” I.D. Hose X 3/8” Male Flare 193397SAE38Hx38MFL 3/8” I.D. Hose X 3/8” Male Flare 182631SAE38Hx12MFL 3/8” I.D. Hose X 1/2” Male Flare
hose barb to Female Pipe Fitting
MFR# DeScRiPTiOn webb#SAE14Hx18F 1/4” I.D. Hose X 1/8” FPT 184998SAE14Hx14F 1/4” I.D. Hose X 1/4” FPT 19941SAE14Hx38F 1/4” I.D. Hose X 3/8” FPT 19942SAE38Hx18F 3/8” I.D. Hose X 1/8” FPT 185000SAE38Hx14F 3/8” I.D. Hose X 1/4” FPT 19946SAE38Hx38F 3/8” I.D. Hose X 3/8” FPT 19947SAE38Hx12F 3/8” I.D. Hose X 1/2” FPT 19948
hose barb to 9/16”—18 lh Female Swivel
MFR# DeScRiPTiOn webb#SAE622-201 3/8” Hose Nip X 9/16”–18 LH Female Swivel 193398
hose barb X Soft nose hand wheel POl
MFR# DeScRiPTiOn webb#SAE14HxMPOLHW 1/4” I.D. Hose X Soft Nose Hand Wheel POL 182646
hose barb X POl
MFR# DeScRiPTiOn webb#SAE14HxMPOL 1/4” I.D. Hose X POL (7/8” Hex) 182655
hose barb X inverted Flare
MFR# DeScRiPTiOn webb#SAE14MX14MINV 1/4” I.D. Hose X 1/4” Inverted Flare Male 182653
Gates lP Grill hoseMFR# DeScRiPTiOn webb#HOS14-2 1/4” Double Braid Hose 185588HOS3/8 3/8” Double Braid Hose 185605HOS1/2 1/2” Double Braid Hose 185581HOS3/4 3/4” Double Braid Hose 185604HOS1ID 1” Double Braid Hose 185591
MFR# Size DeScRiPTiOn webb#HOF7326 .593” Brass Hose Ferrule For 1/4” Hose 185561HOF7327 .625” Brass Hose Ferrule For 1/4” Hose 185562HOF7328 .656” Brass Hose Ferrule For 1/4” Hose 185563*HOF7329 .687” Brass Hose Ferrule For 3/8” Hose 185564HOF7331 .750” Brass Hose Ferrule For 3/8” Hose 185565HOF7332 — Brass Hose Female for 3/8” Hose 252788* HOF7333 .812” Brass Hose Ferrule For 3/8” Hose 185566SPFKT-15 — 3-Hole Crimping Tool For Brass Ferrule 184210
MFR# Size (incheS) lenGTh(FeeT) webb#VCT50A1900030 3/8 6 370042VCT50A1900100 3/8 12 370041VCT50A1900101 3/8 18 370040 HFBLP350X12X6FT 1/2 6 438644HFBLP350X12X10FT 1/2 10 438645HFBLP350X12X15FT 1/2 15 438646HFBLP350X12X18FT 1/2 18 438647HFBLP350X12X20FT 1/2 20 438648HFBLP350X12X25FT 1/2 25 438649HFBLP350X12X50FT 1/2 50 438650HFBLP350X12X100FT 1/2 100 438651
brass hose Ferrule
* Use with current stock thermoid hose.
MFR# DeScRiPTiOn webb#OET10100011 Oetiker 2 Ear Clamp 3/8” 183382OET14100082 Standard Jaw Pinchers 185559OET10100016 Oetiker 2 Ear Clamp 1/2” 183383OET10100019 Oetiker 2 Ear Clamp 9/16” (1/4” Single Braid Hose) 183384OET10100022 Oetiker 2 Ear Clamp 19/32” (1/4” Double Braid Hose) 183385OET10100024 Oetiker 2 Ear Clamp 5/8” (1/4” Double Braid Hose) 183386OET10100027 Oetiker 2 Ear Clamp 3/4” (3/8” Double Braid Hose) 183388OET10100032 Oetiker 2 Ear Clamp 15/16” 183387
ear clamps & Jaw Pinchers
Premade Hose with Male Ends
![Page 146: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/146.jpg)
140 victormfg.com
Fittings 7SECTION
Gas Equipment Catalog
45° elbowMFR# Size webb#MAL1845 1/8” 12559MAL1445 1/4” 12560MAL3845 3/8” 12561MAL1245 1/2” 12562MAL3445 3/4” 12563MAL145 1” 12564MAL11445 11/4” 12565MAL11245 11/2” 12566MAL245 2” 12567MAL21245 21/2” 12568MAL345 3” 12569
45° Street elbowMFR# Size webb#MAL18S45 1/8” 12574MAL14S45 1/4” 12575MAL38S45 3/8” 12576MAL12S45 1/2” 12577MAL34S45 3/4” 12578MAL1S45 1” 12579MAL114S45 11/4” 12580MAL112S45 11/2” 12581MAL2S45 2” 12582
90° elbowMFR# Size webb#MAL1890 1/8” 12503MAL1490 1/4” 12504MAL3890 3/8” 12505MAL1290 1/2” 12506MAL3490 3/4” 12507MAL190 1” 12508MAL11490 11/4” 12509MAL11290 11/2” 12510MAL290 2” 12511MAL21290 21/2” 12512MAL390 3” 12513
90° Street elbowMFR# Size webb#MAL18S90 1/8” 12547MAL14S90 1/4” 12548MAL38S90 3/8” 12549MAL12S90 1/2” 12550MAL34S90 3/4” 12551MAL1S90 1” 12552MAL114S90 11/4” 12553MAL112S90 11/2” 12554MAL2S90 2” 12555MAL212S90 21/2” 12556
crossMFR# Size webb#MAL14CR 1/4” 12760MAL38CR 3/8” 12761MAL12CR 1/2” 12762MAL34CR 3/4” 12763MAL1CR 1” 12764MAL114CR 11/4” 12765MAL112CR 11/2” 12766MAL2CR 2” 12767
couplingMFR# Size webb#MAL18CO 1/8” 12774MAL14CO 1/4” 12775MAL38CO 3/8” 12776MAL12CO 1/2” 12777MAL34CO 3/4” 12778MAL1CO 1” 12779MAL114CO 11/4” 12780MAL112CO 11/2” 12781MAL2CO 2” 12782MAL3CO 3” 12784
TeeMFR# Size webb#MAL18T 1/8” 12586MAL14T 1/4” 12587MAL38T 3/8” 12588MAL12T 1/2” 12589MAL34T 3/4” 12590MAL1T 1” 12591MAL114T 11/4” 12592MAL112T 11/2” 12593MAL2T 2” 12594MAL212T 21/2” 12595MAL3T 3” 12596
Black Malleable Fittings
PlugMFR# Size webb#SolidBCI18SOPL 1/8” 1380BCI14SOPL 1/4” 1381BCI38SOPL 3/8” 1382BCI12SOPL 1/2” 1383BCI34SOPL 3/4” 1371BCI1SOPL 1” 197665BCI2SOPL 2” 1388Cored BCI12PL 1/2” 206693BCI34PL 3/4” 203284BCI1PL 1” 1385BCI114PL 11/4” 1373BCI112PL 11/2” 1387BCI2PL 2” 1375BCI212PL 21/2” 1376BCI3PL 3” 1377
capMFR# Size webb#MAL18CA 1/8” 12851MAL14CA 1/4” 12852MAL38CA 3/8” 12853MAL12CA 1/2” 12854MAL34CA 3/4” 12855MAL1CA 1” 12856MAL114CA 11/4” 12857MAL112CA 11/2” 12858MAL2CA 2” 12859MAL212CA 21/2” 12860MAL3CA 3” 12861
unionMFR# Size webb#MAL18UN 1/8” 54291MAL14UN 1/4” 30254MAL38UN 3/8” 30255MAL12UN 1/2” 30256MAL34UN 3/4” 30257MAL1UN 1” 30258MAL114UN 11/4” 30259MAL112UN 11/2” 30260MAL2UN 2” 30261MAL3UN 3” 30263
90° Reducing elbowMFR# Size webb#MAL14X1890 1/4” X 1/8” 12518MAL38X1490 3/8” X 1/4” 12519MAL12X3890 1/2” X 3/8” 12521MAL12X1490 1/2” X 1/4” 12522MAL34X1290 3/4” X 1/2” 12523MAL34X3890 3/4” X 3/8” 12524MAL34X1490 3/4” X 1/4” 12525MAL1X3490 1” X 3/4” 12526MAL1X1290 1” X 1/2” 12527MAL114X190 11/4” X 1” 12529MAL114X3490 11/4” X 3/4” 12530MAL114X1290 11/4” X 1/2” 12531MAL112X11490 11/2” X 11/4” 12532MAL112X190 11/2” X 1” 12533MAL112X3490 11/2” X 3/4” 12534MAL2X11290 2” X 11/2” 12535MAL2X11490 2” X 11/4” 12536MAL2X190 2” X 1” 12537MAL2X3490 2” X 3/4” 12538MAL212X290 21/2” X 2” 12539MAL212X11290 21/2” X 11/2” 12540MAL3X21290 3” X 21/2” 12541MAL3X290 3” X 2” 12542
![Page 147: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/147.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ga
s p
ipe, t
ub
ing
& f
itt
ing
sFittings
141
7SECTION
7
Black Malleable Fittings (continued)Reducing TeeMFR# Size webb#MAL18X18X14T 1/8” X 1/8” X 1/4” 12601MAL14X14X18T 1/4” X 1/4” X 1/8” 12603MAL38X38X14T 3/8” X 3/8” X 1/4” 12605MAL38X14X14T 3/8” X 1/4” X 1/4” 12608MAL12X12X1T 1/2” X 1/2” X 1” 12609MAL12X12X34T 1/2” X 1/2” X 3/4” 12610MAL12X12X38T 1/2” X 1/2” X 3/8” 12611MAL12X38X12T 1/2” X 3/8” X 1/2” 12613MAL12X38X38T 1/2” X 3/8” X 3/8” 12614MAL12X14X12T 1/2” X 1/4” X 1/2” 12615MAL34X12X12T 3/4” X 1/2” X 1/2” 12622MAL34X12X34T 3/4” X 1/2” X 3/4” 12621MAL34X14X34T 3/4” X 1/4” X 3/4” 12625MAL34X34X114T 3/4” X 3/4” X 11/4” 12616MAL34X34X12T 3/4” X 3/4” X 1/2” 12618MAL34X34X14T 3/4” X 3/4” X 1/4” 12620MAL34X34X1T 3/4” X 3/4” X 1” 12617MAL34X34X38T 3/4” X 3/4” X 3/8” 12619MAL1X1X12T 1” X 1” X 1/2” 30252MAL1X1X112T 1” X 1” X 11/2” 12627MA1X1X114T 1” X 1” X 11/4” 12628MAL1X1X38T 1” X 1” X 3/8” 12631MAL1X1X14T 1” X 1” X 1/4” 12632MAL1X34X1T 1” X 3/4” X 1” 12633MAL1X34X34T 1” X 3/4” X 3/4” 12634MAL1X34X12T 1” X 3/4” X 1/2” 12635MAL1X12X1T 1” X 1/2” X 1” 12636MAL1X12X34T 1” X 1/2” X 3/4” 12637MAL1X12X12T 1” X 1/2” X 1/2” 12638MAL1X14X1T 1” X 1/4” X 1” 12639MAL114X114X2T 11/4” X 11/4” X 2” 12640MAL114X114X112T 11/4” X 11/4” X 11/2” 12641MAL114X114X1T 11/4” X 11/4” X 1” 12642MAL114X114X34T 11/4” X 11/4” X 3/4” 12643MAL114X114X12T 11/4” X 11/4” X 1/2” 12644MAL114X1X114T 11/4” X 1” X 11/4” 12647MAL114X1X1T 11/4” X 1” X 1” 12648MAL114X1X34T 11/4” X 1” X 3/4” 12649MAL114X1X12T 11/4” X 1” X 1/2” 12650MAL114X34X114T 11/4” X 3/4” X 11/4” 12651MAL114X34X1T 11/4” X 3/4” X 1” 12652MAL114X34X34T 11/4” X 3/4” X 3/4” 12653MAL114X12X114T 11/4” X 1/2” X 11/4” 12655MAL114X12X1T 11/4” X 1/2” X 1” 12656MAL112X112X2T 11/2” X 11/2” X 2” 12661MAL112X112X114T 11/2” X 11/2” X 11/4” 12662MAL112X112X1T 11/2” X 11/2” X 1” 12663MAL112X112X34T 11/2” X 11/2” X 3/4” 12664MAL112x112x12T 11/2” X 11/2” X 1/2” 12665
Reducing Tee (continued)
MFR# Size webb#MAL112X114X112T 11/2” X 11/4” X 11/2” 12667MAL112X114X114T 11/2” X 11/4” X 11/4” 12668MAL112X114X1T 11/2” X 11/4” X 1” 12669MAL112X114X34T 11/2” X 11/4” X 3/4” 12670MAL112X114X12T 11/2” X 11/4” X 1/2” 12671MAL112X1X112T 11/2” X 1” X 11/2” 12672MAL112X1X114T 11/2” X 1” X 11/4” 12673MAL112X1X1T 11/2” X 1” X 1” 12674MAL112X1X34T 11/2” X 1” X 3/4” 12675MAL112X34X112T 11/2” X 3/4” X 11/2” 12677MAL112X34X34T 11/2” X 3/4” X 3/4” 12680MAL112X12X112T 11/2” X 1/2” X 11/2” 12681MAL2X2X212T 2” X 2” X 21/2” 12684MAL2X2X112T 2” X 2” X 11/2” 12685MAL2X2X114T 2” X 2” X 11/4” 12686MAL2X2X1T 2” X 2” X 1” 12687MAL2X2X34T 2” X 2” X 3/4” 12688MAL2X2X12T 2” X 2” X 1/2” 12689MAL2X112X2T 2” X 11/2” X 2” 12690MAL2X112X112T 2” X 11/2” X 11/2” 12691MAL2X112X114T 2” X 11/2” X 11/4” 12692MAL2X112X1T 2” X 11/2” X 1” 12693MAL2X112X34T 2” X 11/2” X 3/4” 12694MAL2X114X2T 2” X 11/4” X 2” 12695MAL2X114X114T 2” X 11/4” X 11/4” 12697MAL2X1X2T 2” X 1” X 2” 12699MAL2X1X1T 2” X 1” X 1” 12702MAL2X34X2T 2” X 3/4” X 2” 12704MAL2X12X2T 2” X 1/2” X 2” 12706MAL212X212X2T 21/2” X 21/2” X 2” 12708MAL212X212X112T 21/2” X 21/2” X 11/2” 12709MAL212X212X114T 21/2” X 21/2” X 11/4” 12710MAL212X212X1T 21/2” X 21/2” X 1” 12711MAL212X212X34T 21/2” X 21/2” X 3/4” 12712MAL212X2X212T 21/2” X 2” X 21/2” 12713MAL212X2X2T 21/2” X 2” X 2” 12714MAL212X112X2T 21/2” X 11/2” X 2” 12717MAL3X3X212T 3” X 3” X 21/2” 12719MAL3X3X2T 3” X 3” X 2” 12720MAL3X3X112T 3” X 3” X 11/2” 12721MAL3X3X114T 3” X 3” X 11/4” 12722MAL3X3X1T 3” X 3” X 1” 12723MAL3X3X34T 3” X 3” X 3/4” 12724MAL3X212X2T 3” X 21/2” X 2” 12727MAL3X2X3T 3” X 2” X 3” 12729MAL3X2X2T 3” X 2” X 2” 12730
Reducing couplingMFR# Size webb#MAL14X18CO 1/4” X 1/8” 12789MAL38X14CO 3/8” X 1/4” 12790MAL38X18CO 3/8” X 1/8” 12791MAL12X38CO 1/2” X 3/8” 12792MAL12X14CO 1/2” X 1/4” 12793MAL12X18CO 1/2” X 1/8” 12794MAL34X12CO 3/4” X 1/2” 12795MAL34X38CO 3/4” X 3/8” 12796MAL34X14CO 3/4” X 1/4” 12797MAL34X18CO 3/4” X 1/8” 12798MAL1X34CO 1” X 3/4” 12799MAL1X12CO 1” X 1/2” 12800MAL1X38CO 1” X 3/8” 12801MAL1X14CO 1” X 1/4” 12802MAL114X1CO 11/4” X 1” 12803MAL114X34CO 11/4” X 3/4” 12804MAL114X12CO 11/4” X 1/2” 12805MAL114X38CO 11/4” X 3/8” 12806MAL112X114CO 11/2” X 11/4” 12808MAL112X1CO 11/2” X 1” 12809MAL112X34CO 11/2” X 3/4” 12810MAL112X12CO 11/2” X 1/2” 12811MAL2X112CO 2” X 11/2” 12813MAL2X114CO 2” X 11/4” 12814MAL2X1CO 2” X 1” 12815MAL2X34CO 2” X 3/4” 12816MAL2X12CO 2” X 1/2” 12817MAL212X2CO 21/2” X 2” 12818MAL212X112CO 21/2” X 11/2” 12819MAL212X114CO 21/2” X 11/4” 12820MAL212X1CO 21/2” X 1” 12821MAL3X212CO 3” X 21/2” 12822MAL3X2CO 3” X 2” 12823MAL3X112CO 3” X 11/2” 12824MAL3X114CO 3” X 11/4” 12825MAL3X1CO 3” X 1” 12826
Floor FlangesMFR# Size webb#MAL12FLFLG 1/2” 12879MAL34FLFLG 3/4” 12880MAL1FLFLG 1” 12881MAL114FLFLG 11/4” 12882MAL112FLFLG 11/2” 12883MAL2FLFLG 2” 12884
![Page 148: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/148.jpg)
142 victormfg.com
Fittings 7SECTION
Gas Equipment Catalog
MFR# webb# MFR# webb# MFR# webb# MFR# webb# MFR# webb# MFR# webb# Size 1/8” 1/4” 3/8” 1/2” 3/4” 1”
CLOSE NIP18XCLO 14121 NIP14XCLO 14132 NIP38XCLO 14143 NIP12XCLO 14154 NIP34XCLO 14171 NIP1XCLO 14188 1 NIP14X1 90178 11/2 NIP18X112 14122 NIP14X112 14133 NIP38X112 14144 NIP12X112 14155 NIP34X112 14172 2 NIP18X2 14123 NIP14X2 14134 NIP38X2 14145 NIP12X2 14156 NIP34X2 14173 NIP1X2 14189 21/2 NIP18X212 14124 NIP14X212 14135 NIP38X212 14146 NIP12X212 14157 NIP34X212 14174 NIP1X212 14190 3 NIP18X3 14125 NIP14X3 14136 NIP38X3 14147 NIP12X3 14158 NIP34X3 14175 NIP1X3 14191 31/2 NIP18X312 14126 NIP14X312 14137 NIP38X312 14148 NIP12X312 14159 NIP34X312 14176 NIP1X312 14192 4 NIP18X4 14127 NIP14X4 14138 NIP38X4 14149 NIP12X4 14160 NIP34X4 14177 NIP1X4 14193 41/2 NIP18X412 14128 NIP14X412 14139 NIP38X412 14150 NIP12X412 14161 NIP34X412 14178 NIP1X412 14194 5 NIP18X5 14129 NIP14X5 14140 NIP38X5 14151 NIP12X5 14162 NIP34X5 14179 NIP1X5 14195 51/2 NIP18X512 14130 NIP14X512 14141 NIP38X512 14152 NIP12X512 14163 NIP34X512 14180 NIP1X512 14196 6 NIP18X6 14131 NIP14X6 14142 NIP38X6 14153 NIP12X6 14164 NIP34X6 14181 NIP1X6 14197 61/2 NIP12X612 90214 NIP34X612 86309 7 NIP18X7 110506 NIP14X7 93181 NIP38X7 67730 NIP12X7 14165 NIP34X7 14182 NIP1X7 14198 71/2 NIP12X712 225065 8 NIP18X8 89010 NIP14X8 90181 NIP38X8 110509 NIP12X8 14166 NIP34X8 14183 NIP1X8 14199 81/2 9 NIP14X9 86243 NIP38X9 213167 NIP12X9 14167 NIP34X9 14184 NIP1X9 14200 91/2 10 NIP18X10 153238 NIP14X10 90179 NIP38X10 79993 NIP12X10 14168 NIP34X10 14185 NIP1X10 14201 101/2 11 NIP14X11 206628 NIP38X11 90199 NIP12X11 14169 NIP34X11 14186 NIP1X11 14202 12 NIP14X12 90180 NIP38X12I 153004 NIP12X12 14170 NIP34X12 14187 NIP1X12 14203 13 14 15 16 17 171/2 18 NIP14X18 14776 NIP38X18 14784 NIP12X18 14792 NIP34X18 14800 NIP1X18 14808 19 20 NIP34X20 90233 21 22 24 NIP14X24 14777 NIP38X24 14785 NIP12X24 14793 NIP34X24 14801 NIP1X24 14809 26 27 28 30 NIP12X30 14794 NIP34X30 14802 NIP1X30 14810 36 NIP14X36 14779 NIP12X36 14795 NIP34X36 14803 NIP1X36 14811 40 42 43 48 NIP14X48 14781 NIP12X48 14797 NIP34X48 14805 NIP1X48 14813 53 54 60 NIP12X60 14799 NIP34X60 14807 NIP1X60 14815
Schedule 40 Nipples1/8” — 1”
![Page 149: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/149.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ga
s p
ipe, t
ub
ing
& f
itt
ing
sFittings
143
7SECTION
7
MFR# webb# MFR# webb# MFR# webb# MFR# webb# MFR# webb# Size 11/4” 11/2” 2” 21/2” 3”
CLOSE NIP114XCLO 14204 NIP112XCLO 14219 NIP2XCLO 14235 NIP212XCLO 14250 NIP3XCLO 14264 1 2 NIP114X2 14205 NIP112X2 14220 21/2 NIP114X212 14206 NIP112X212 14221 NIP2X212 14236 3 NIP114X3 14207 NIP112X3 14222 NIP2X3 14237 NIP212X3 14251 NIP3X3 14265 31/2 NIP114X312 14208 NIP112X312 14223 NIP2X312 14238 NIP212X312 14252 NIP3X312 14266 4 NIP114X4 14209 NIP112X4 14224 NIP2X4 14239 NIP212X4 14253 NIP3X4 14267 41/2 NIP114X412 14210 NIP112X412 14225 NIP2X412 14240 NIP212X412 14254 NIP3X412 14268 5 NIP114X5 14211 NIP112X5 14226 NIP2X5 14241 NIP212X5 14255 NIP3X5 14269 51/2 NIP114X512 14212 NIP112X512 14227 NIP2X512 14242 NIP212X512 14256 NIP3X512 14270 6 NIP114X6 14213 NIP112X6 14228 NIP2X6 14243 NIP212X6 14257 NIP3X6 14271 61/2 7 NIP114X7 14214 NIP112X7 14229 NIP2X7 14244 NIP212X7 14258 NIP3X7 14272 71/2 8 NIP114X8 14215 NIP112X8 14230 NIP2X8 14245 NIP212X8 14259 NIP3X8 14273 81/2 9 NIP114X9 14216 NIP112X9 14231 NIP2X9 14246 NIP212X9 14260 NIP3X9 14274 91/2 10 NIP114X10 30269 NIP112X10 14232 NIP2X10 14247 NIP212X10 14261 NIP3X10 14275 101/2 11 NIP114X11 14217 NIP112X11 14233 NIP2X11 14248 NIP212X11 14262 NIP3X11 14276 12 NIP114X12 14218 NIP112X12 14234 NIP2X12 14249 NIP212X12 14263 NIP3X12 14277 16 17 171/2 18 NIP114X18 14816 NIP112X18 14824 NIP2X18 14832 NIP212X18 67733 NIP3X18 67324 21 22 24 NIP114X24 14817 NIP112X24 14825 NIP2X24 14833 NIP212X24 86476 NIP3X24 67325 27 28 30 NIP114X30 14818 NIP112X30 14826 NIP2X30 14834 NIP212X30 200226 NIP3X30 67326 36 NIP114X36 14819 NIP112X36 14827 NIP2X36 14835 NIP3X36 67327 40 43 48 NIP114X48 14821 NIP112X48 14829 NIP2X48 14837 53 60 NIP114X60 14823 NIP2X60 14839
Schedule 40 Nipples (continued)11/4” — 3”
![Page 150: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/150.jpg)
144 victormfg.com
Fittings 7SECTION
Gas Equipment Catalog
Forged Steel Fittings, 3000# Socket Weld
MFR# Size webb#F/S12X14I3SW 1/2” X 1/4” 30641F/S12X38ISW 1/2” X 3/8” 9050F/S34X14I3SW 3/4” X 1/4” 9054F/S34X38I3SW 3/4” X 3/8” 9053F/S34X12I3SW 3/4” X 1/2” 9052F/S1X38I3SW 1” X 3/8” 9058F/S1X12I3SW 1” X 1/2” 9057F/S1X34I3SW 1” X 3/4” 9056F/S114X12I3SW 11/4” X 1/2” 9063F/S114X34I3SW 11/4” X 3/4” 30642F/S114X1I3SW 11/4” X 1” 9061F/S112X12I3SW 11/2” X 1/2” 9069F/S112X34I3SW 11/2” X 3/4” 9068F/S112X1I3SW 11/2” X 1” 9067F/S112X114I3SW 11/2” X 11/4” 9066F/S2X112I3SW 2” X 11/2” 9072F/S2X114I3SW 2” X 11/4” 9073F/S2X1I3SW 2” X 1” 9074F/S2X34I3SW 2” X 3/4” 9075F/S2X12I3SW 2” X 1/2” 9076F/S212X2I3SW 21/2” X 2” 200488F/S3X212I3SW 3” X 21/2” 69452
MFR# Size webb#F/S12X14R3SW 1/2” X 1/4” 34914F/S12X38R3SW 1/2” X 3/8” 34915F/S34X14CO3SW 3/4” X 1/4” 8986F/S34X38R3SW 3/4” X 3/8” 34928F/S34X12R3SW 3/4” X 1/2” 34927F/S1X14CO3SW 1” X 1/4” 8991F/S1X38CO3SW 1” X 3/8” 8990F/S1X12R3SW 1” X 1/2” 34918F/S1X34R3SW 1” X 3/4” 34919F/S114X12R3SW 11/4” X 1/2” 34910F/S114X34R3SW 11/4” X 3/4” 34912F/S114X1R3SW 11/4” X 1” 34911F/S112X12R3SW 11/2” X 1/2” 34905F/S112X34R3SW 11/2” X 3/4” 34908F/S112X1R3SW 11/2” X 1” 34906F/S112X114R3SW 11/2” X 11/4” 34903F/S2X112R3SW 2” X 11/2” 34921F/S2X114R3SW 2” X 11/4” 34922F/S2X1R3SW 2” X 1” 9006F/S2X34R3SW 2” X 3/4” 9007F/S2X12R3SW 2” X 1/2” 9008F/S212X2R3SW 21/2” X 2” 81774F/S212X112R3SW 21/2” X 11/2” 202425F/S212X114CO3SW 21/2” X 11/4” 200481
unionMFR# Size webb#F/S12UN3SW 1/2” 9109F/S34UN3SW 3/4” 9110F/S1UN3SW 1” 9111F/S114UN3SW 11/4” 9112F/S112UN3SW 11/2” 9113F/S2UN3SW 2” 9114F/S212UN3SW 21/2” 9115F/S3UN3SW 3” 9116
45° elbowMFR# Size webb#F/S12453SW 1/2” 8933F/S34453SW 3/4” 8934F/S1453SW 1” 8935F/S114453SW 11/4” 8936F/S112453SW 11/2” 8937F/S2453SW 2” 8938F/S212453SW 21/2” 8939F/S3453SW 3” 8940
90° elbow MFR# Size webb#F/S12903SW 1/2” 8921F/S34903SW 3/4” 8922F/S1903SW 1” 8923F/S114903SW 11/4” 8924F/S112903SW 11/2” 8925F/S2903SW 2” 8926F/S212903SW 21/2” 8927F/S3903SW 3” 8928
capMFR# Size webb#F/S12CA3SW 1/2” 9041F/S34CA3SW 3/4” 9042F/S1CA3SW 1” 9043F/S114CA3SW 11/4” 9044F/S112CA3SW 11/2” 9045F/S2CA3SW 2” 9046F/S212CA3SW 21/2” 81754F/S3CA3SW 3” 9048
insert
TeeMFR# Size webb#F/S12T3SW 1/2” 8945F/S34T3SW 3/4” 8946F/S1X12T3SW 1” X 1” X 1/2” 86648F/S114T3SW 11/4” 8948F/S112T3SW 11/2” 8949F/S2T3SW 2” 8950F/S212T3SW 21/2” 8951F/S3T3SW 3” 8952F/S34X12T3SW 3/4” X 3/4” X 1/2” 177016F/S112X1T3SW 11/2” X 11/2” X 1” 77863F/S2X1T3SW 2” X 2” X 1” 77864F/S2X112T3SW 2” X 11/2” 90134F/S1T3SW 1” 8947F/S112X34T3SW 11/2” X 11/2” X 3/4” 77862F/S2X112T3SW 2” X 2” X 11/2” 90134
Reducing ElbowMFR# Size webb#F/S34X12903SW 3/4” X 1/2” 172849F/S1X12903SW 1” X 1/2” 172938
Reducer coupling
crossMFR# Size webb#F/S1CR3SW 1” 84306F/S2CRS3SW 2” 77868
![Page 151: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/151.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ga
s p
ipe, t
ub
ing
& f
itt
ing
sFittings
145
7SECTION
7
couplingMFR# Size webb#F/S12CO3SW 1/2” 8957F/S34CO3SW 3/4” 8958F/S1CO3SW 1” 8959F/S114CO3SW 11/4” 8960F/S112CO3SW 11/2” 8961F/S2CO3SW 2” 8962F/S212CO3SW 21/2” 8963F/S3CO3SW 3” 8964
half couplingMFR# Size webb#F/S12HCO3SW 1/2” 8969F/S34HCO3SW 3/4” 8970F/S1HCO3SW 1” 8971F/S114HCO3SW 11/4” 8972F/S112HCO3SW 11/2” 8973F/S2HCO3SW 2” 8974F/S212HCO3SW 21/2” 8975F/S3HCO3SW 3” 8976
Forged Steel Fittings 3000# Socket Weld
Socket Welding Flanges Class 300
MFR# Size webb#threaded or Screwed FlangesW/F12300THDFLG 1/2” 27934W/F34300THDFLG 3/4” 27935W/F1300THDFLG 1” 27936W/F114300THDFLG 11/4” 27937W/F112300THDFLG 11/2” 73679W/F2300THDFLG 2” 27939W/F212300THDFLG 21/2” 27940W/F3300THDFLG 3” 27941W/F4300THDFLG 4” 27942W/F6300THDFLG 6” 27943blind FlangesW/F12300BLFLG 1/2” 27944W/F34300BLFLG 3/4” 27945W/F1300BLFLG 1” 27946W/F114300BLFLG 11/4” 27947W/F112300BLFLG 11/2” 27948W/F2300BLFLG 2” 27949W/F212300BLFLG 21/2” 27950W/F3300BLFLG 3” 27951W/F4300BLFLG 4” 27952W/F5300BLFLG 5” 27953W/F6300BLFLG 6” 27954W/F8300BLFLG 8” 27955W/F10300BLFLG 10” 27956W/F12I300BLFLG 12” 27957Gaskets for SWG 300# Flange1/2” 55404 3” 554113/4” 55405 4” 554131” 55406 5” 5541411/4” 55407 6” 5541511/2” 55408 8” 554162” 55409 10” 5541721/2” 55410 12” 55418
MFR# Size webb#Weld neck FlangesW/F12300WNFLG 1/2” 27896W/F34300WNFLG 3/4” 27897W/F1300WNFLG 1” 27898W/F114300WNFLG 11/4” 27899W/F112300WNFLG 11/2” 27900W/F2300WNFLG 2” 27901W/F212300WNFLG 21/2” 27902W/F3300WNFLG 3” 27903W/F4300WNFLG 4” 27904W/F5300WNFLG 5” 27905W/F6300WNFLG 6” 27906W/F8300WNFLG 8” 27907W/F10300WNFLG 10” 27908W/F12I300WNFLG 12” 27909Slip on FlangesW/F12300SOFLG 1/2” 27915W/F34300SOFLG 3/4” 27916W/F1300SOFLG 1” 27917W/F114300SOFLG 11/4” 27918W/F112300SOFLG 11/2” 27919W/F2300SOFLG 2” 27920W/F212300SOFLG 21/2” 27921W/F3300SOFLG 3” 27922W/F4300SOFLG 4” 27923W/F5300SOFLG 5” 27924W/F6300SOFLG 6” 27925W/F8300SOFLG 8” 27926W/F10300SOFLG 10” 27927W/F12I300SOFLG 12” 27928Gaskets for Manway 150#SWG160010008 16” 308728SWG180010017 18” 202009SWG200010017 20” 202010
MFR# Size webb#HGR12X2B7 1/2” X 2” 119109HGR12X214B7 1/2” X 21/4” 119110HGR12X212B7 1/2” X 21/2” 119111HGR12X234B7 1/2” X 23/4” 119112HGR58X212B7 5/8” X 21/2” 119113HGR58X234B7 5/8” X 23/4” 119114HGR58X3B7 5/8” X 3” 119115HGR58X314B7 5/8” X 31/4” 119116HGR58X312B7 5/8” X 31/2” 119117HGR58X375B7 5/8” X 33/4” 424777HGR34X3B7 3/4” X 3” 119118HGR34X314B7 3/4” X 31/4” 119119HGR34X312B7 3/4” X 31/2” 119120HGR34X334B7 3/4” X 33/4” 119121HGR34X4B7 3/4” X 4” 119122HGR34X414B7 3/4” X 41/4” 119123HGR78X4B7 7/8” X 4” 119124HGR78X434B7 7/8” X 43/4” 119126
b7 Studs
Flange Accessories
MFR# Size webb#HGR12NUT2H 1/2” 119129HGR58NUT2H 5/8” 119130HGR34NUT2H 3/4” 119131HGR78NUT2H 7/8” 119132
2h nuts
1”, 11/8” studs, available upon request.
![Page 152: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/152.jpg)
146 victormfg.com
Fittings 7SECTION
Gas Equipment Catalog
PiPe SizeDiaMeTeR OF bOlT ciRcle DiaMeTeR OF bOlT nO. OF bOlTS
lenGTh OF STuD1/16” RaiSeD Face bOlT lenGTh
1/2” 25/8” 1/2” 4 21/2” 2”3/4” 31/4” 5/8” 4 23/4” 21/2”1” 31/2” 5/8” 4 3” 21/2”
11/4” 37/8” 5/8” 4 3” 23/4”11/2” 41/2” 3/4” 4 31/2” 3”
2” 5” 5/8” 8 31/4” 3”21/2” 57/8” 3/4” 8 33/4” 31/4”
3” 65/8” 3/4” 8 4” 31/2”31/2” 71/4” 3/4” 8 41/4” 33/4”
4” 77/8” 3/4” 8 41/4” 33/4”5” 91/4” 3/4” 8 41/2” 4”6” 105/8” 3/4” 12 43/4” 41/4”7” 13” 3/4” 12 51/4” 43/4”
10” 151/4” 1” 16 6” 51/4”12” 173/4” 11/8” 16 61/2” 53/4”14” 201/4” 11/8” 20 63/4” 6”16” 221/2” 11/4” 20 71/4” 61/2”18” 243/4” 11/4” 24 71/2” 63/4”20” 27” 11/4” 24 8” 7”22” 291/4” 11/2” 24 83/4” 71/2”24” 32” 11/2” 24 9” 73/4”26” 341/2” 15/8” 28 10” 83/4”30” 391/4” 13/4” 28 111/4” 10”34” 431/2” 17/8” 28 121/4” 103/4”36” 46” 2” 32 123/4” 111/4”42” 523/4” 2” 36 133/4” 131/2”
Flange Size Chart for Stud/Bolt Length
45° elbowMFR# Size webb#3000#F/S14453SE 1/4” 8700F/S38903SE 3/8” 8689F/S12453SE 1/2” 8702F/S34453SE 3/4” 8703F/S1453SE 1” 8704F/S114453SE 11/4” 8705F/S112453SE 11/2” 8706F/S2453SE 2” 8707F/S3453SE 3” 1545322000#F/S14452SE 1/4” 8665F/S114452SE 11/4” 8670F/S3452SE 3” 8674
90° elbowMFR# Size webb#3000# F/S14903SE 1/4” 8688F/S12903SE 1/2” 8690F/S34903SE 3/4” 8691F/S1903SE 1” 8692F/S114903SE 11/4” 8693F/S112903SE 11/2” 8694F/S2903SE 2” 8695F/S212903SE 21/2” 8696F/S3903SE 3” 86972000#F/S14902SE 1/4” 8654F/S12902SE 1/2” 8656F/S2902SE 2” 8661F/S34902SE 3/4” 8657F/S1902SE 1” 8658F/S114902SE 11/4” 8659F/S112902SE 11/2” 8660F/S2902SE 2” 8661F/S212902SE 21/2” 8662F/S3902SE 3” 8663
90° Street elbow — 3000#F/S14S903SE 1/4” 8723F/S38S903SE 3/8” 8724F/S12S903SE 1/2” 8725F/S34S903SE 3/4” 8726F/S1S903SE 1” 8727F/S114S903SE 11/4” 8728F/S112S903SE 11/2” 8729F/S2S903SE 2” 8730
Reducing elbowMFR# Size webb#3000#F/S1X34903SE 1” X 3/4” 216219F/S1X12903SE 1” X 1/2” 210687F/S2X112903SE 2” X 11/2” 206543
Forged Steel Fittings threaded
MFR# Size webb#3000#F/S14CO3SE 1/4” 8732F/S38CO3SE 3/8” 8733F/S12CO3SE 1/2” 8734F/S34CO3SE 3/4” 8735F/S1CO3SE 1” 8736F/S114CO3SE 11/4” 8737F/S112CO3SE 11/2” 8738F/S2CO3SE 2” 8739F/S212CO3SE 21/2” 8740F/S3CO3SE 3” 8741
Cross MFR# Size webb#3000# F/S38CR3SE 3/8” 222407F/S12CR3SE 1/2” 180085F/S34CR3SE 3/4” 187210F/S1CR3SE 1” 110425F/S114CR3SE 11/4” 200465F/S112CR3SE 11/2” 184610F/S2CR3SE 2” 223961F/S3CR3SE 3” 187211
Square head PlugMFR# Size webb#3000#F/S14PL 1/4” 8828F/S38PL 3/8” 8829F/S12PL 1/2” 8830F/S34PL 3/4” 8831F/S1PL 1” 8832F/S114PL 11/4” 8833F/S112PL 11/2” 8834F/S2PL 2” 8835F/S212PL 21/2” 8836F/S3PL 3” 8837
coupling
cross
![Page 153: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/153.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ga
s p
ipe, t
ub
ing
& f
itt
ing
sFittings
147
7SECTION
7
MFR# Size webb#3000# F/S14T3SE 1/4” 8712F/S38T3SE 3/8” 8713F/S12T3SE 1/2” 8714F/S34T3SE 3/4” 8715F/S1T3SE 1” 8716F/S114T3SE 11/4” 8717F/S112T3SE 11/2” 8718F/S2T3SE 2” 8719F/S212T3SE 21/2” 87202000# F/S14T2SE 1/4” 8676F/S38T2SE 3/8” 8677F/S12T2SE 1/2” 8678F/S34T2SE 3/4” 8679F/S1T2SE 1” 8680F/S114T2SE 11/4” 8681F/S112T2SE 11/2” 8682F/S2T2SE 2” 8683F/S212T2SE 21/2” 8684F/S3T2SE 3” 8685
Forged Steel Fittings – threaded
MFR# Size webb#3000#F/S14X18BU 1/4” X 1/8” 8851F/S38X18BU 3/8” X 1/8” 8853F/S38X14BU 3/8” X 1/4” 8852F/S12X18BU 1/2” X 1/8” 8856F/S12X14BU 1/2” X 1/4” 8855F/S12X38BU 1/2” X 1/8” 8854F/S34X18BU 3/4” X 1/8” 8860F/S34X14BU 3/4” X 1/4” 8859F/S34X38BU 3/4” X 3/8” 8858F/S34X12BU 3/4” X 1/2” 8857F/S1X18BU 1” X 1/8” 8865F/S1X14BU 1” X 1/4” 8864F/S1X38BU 1” X 1/8” 8863F/S1X12BU 1” X 1/2” 8862F/S1X34BU 1” X 3/4” 8861F/S114X14BU 11/4” X 1/4” 8870F/S114X38BU 11/4” X 3/8” 8869F/S114X12BU 11/4” X 1/2” 8868F/S114X34BU 11/4” X 3/4” 8867F/S114X1BU 11/4” X 1” 8866F/S112X14BU 11/2” X 1/4” 8877F/S112X38BU 11/2” X 3/8” 8876F/S112X12BU 11/2” X 1/2” 8875F/S112X34BU 11/2” X 3/4” 8874F/S112X1BU 11/2” X 1” 8873F/S112X114BU 11/2” X 11/4” 8872F/S2X14BU 2” X 1/4” 8885F/S2X38BU 2” X 3/8” 8884F/S2X12BU 2” X 1/2” 8883F/S2X34BU 2” X 3/4” 8882F/S2X1BU 2” X 1” 8881F/S2X114BU 2” X 11/4” 8880F/S2X112BU 2” X 11/2” 8879F/S212X14BU 21/2” X 1/4” 8894F/S212X34BU 21/2” X 3/4” 8891F/S212X1BU 21/2” X 1” 8890F/S212X114BU 21/2” X 11/4” 8889F/S212X112BU 21/2” X 11/2” 8888F/S212X2BU 21/2” X 2” 8887F/S3X12BU 3” X 1/2” 8902F/S3X1BU 3” X 1” 8900F/S3X114BU 3” X 11/4” 8899F/S3X112BU 3” X 11/2” 8898F/S3X2BU 3” X 2” 8897F/S3X212BU 3” X 21/2” 8896
bushing
capMFR# Size webb#3000#F/S14CA3SE 1/4” 8816F/S38CA3SE 3/8” 8817F/S12CA3SE 1/2” 8818F/S34CA3SE 3/4” 8819F/S1CA3SE 1” 8820F/S114CA3SE 11/4” 8821F/S112CA3SE 11/2” 8822F/S2CA3SE 2” 8823F/S212CA3SE 21/2” 8824F/S3CA3SE 3” 8825
Tee
S40 Plain end S40 Threaded S80
MFR# Size webb#3000#F/S14X18R3SE 1/4” X 1/8” 8755F/S38X14R3SE 3/8” X 1/4” 8756F/S38X18RED3SE 3/8” X 1/8” 8757F/S12X14R3SE 1/2” X 1/4” 8759F/S12X38R3SE 1/2” X 3/8” 8758F/S34X14R3SE 3/4” X 1/4” 166093F/S34X38R3SE 3/4” X 3/8” 8762F/S34X12R3SE 3/4” X 1/2” 8761F/S1X14RED3SE 1” X 1/4” 8768F/S1X12R3SE 1” X 1/2” 8766F/S1X34R3SE 1” X 3/4” 8765F/S114X12R3SE 11/4” X 1/2” 34909F/S114X34R3SE 11/4” X 3/4” 8771F/S114X1R3SE 11/4” X 1” 8770F/S112X12R3SE 11/2” X 1/2” 34904F/S112X34R3SE 11/2” X 3/4” 34907F/S112X1R3SE 11/2” X 1” 8776F/S112X114R3SE 11/2” X 11/4” 8775F/S2X12R3SE 2” X 1/2” 34923F/S2X34R3SE 2” X 3/4” 34925F/S2X1R3SE 2” X 1” 34924F/S2X114R3SE 2” X 11/4” 8782F/S2X112R3SE 2” X 11/2” 8781F/S212X2R3SE 21/2” X 2” 81759F/S212X112R3SE 21/2” X 11/2” 81756F/S212X1R3SE 21/2” X 1” 209413F/S3X212R3SE 3” X 21/2” 81764F/S3X2R3SE 3” X 2” 155613F/S3X112R3SE 3” X 11/2” 209415
half couplingMFR# Size webb#3000#F/S14HCO3SE 1/4” 8744F/S38HCO3SE 3/8” 8745F/S12HCO3SE 1/2” 8746F/S34HCO3SE 3/4” 8747F/S1HCO3SE 1” 8748F/S114HCO3SE 11/4” 8749F/S112HCO3SE 11/2” 8750F/S2HCO3SE 2” 8751F/S212HCO3SE 21/2” 8752F/S3HCO3SE 3” 110427
unionMFR# Size webb#3000# F/S14UN3SE 1/4” 9096F/S38UN3SE 3/8” 9097F/S12UN3SE 1/2” 9098F/S34UN3SE 3/4” 9099F/S1UN3SE 1” 9100F/S114UN3SE 11/4” 9101F/S112UN3SE 11/2” 9102F/S2UN3SE 2” 9103F/S212UN3SE 21/2” 9104F/S3UN3SE 3” 9105
Reducer coupling
Schedules 40 & 80 Black Pipe
MFR# Size webb#Plain endD/P14BPE 1/4” 179384D/P38BPE 3/8” 79878D/P12BPE 1/2” 45484D/P34BPE 3/4” 45500D/P1BPE 1” 45518D/P114BPE 11/4” 45533D/P112BPE 11/2” 45488D/P2BPE 2” 45504D/P212BPE 21/2” 45522D/P3BPE 3” 45474D/P4BPE 4” 45508
MFR# Size webb#threaded & Capped endsD/P38BTC 3/8” 45473D/P12BTC 1/2” 45490D/P34BTC 3/4” 45507D/P1BTC 1” 45524D/P114BTC 11/4” 45477D/P112BTC 11/2” 45493D/P2BTC 2” 45511D/P212BTC 21/2” 45527D/P3BTC 3” 45480D/P4BTC 4” 45514
MFR# Size webb#Plain endD/P14XHBPE 1/4” 45475D/P12XHBPE 1/2” 45525D/P34XHBPE 3/4” 45478D/P1XHBPE 1” 45494D/P114XHBPE 11/4” 45512D/P112XHBPE 11/2” 45528D/P2XHBPE 2” 45482D/P212XHBPE 21/2” 45498D/P3XHBPE 3” 45516D/P4XHBPE 4” 45486
![Page 154: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/154.jpg)
148 victormfg.com
Fittings 7SECTION
Gas Equipment Catalog
MFR# webb# MFR# webb# MFR# webb# MFR# webb# MFR# webb# Size 1/4” 3/8” 1/2” 3/4” 1” CLOSE NIP14XCLOXH 14541 NIP38XCLOXH 14558 NIP12XCLOXH 14575 NIP34XCLOXH 14592 NIP1XCLOXH 14609 11/2 NIP14X112XH 14542 NIP38X112XH 14559 NIP12X112XH 14576 NIP34X112XH 14593 2 NIP14X2XH 14543 NIP38X2XH 14560 NIP12X2XH 14577 NIP34X2XH 14594 NIP1X2XH 14610 21/2 NIP14X212XH 14544 NIP38X212XH 14561 NIP12X212XH 14578 NIP34X212XH 14595 NIP1X212XH 14611 3 NIP14X3XH 14545 NIP38X3XH 14562 NIP12X3XH 14579 NIP34X3XH 14596 NIP1X3XH 14612 31/2 NIP14X312XH 14546 NIP38X312XH 14563 NIP12X312XH 14580 NIP34X312XH 14597 NIP1X312XH 14613 4 NIP14X4XH 14547 NIP38X4XH 14564 NIP12X4XH 14581 NIP34X4XH 14598 NIP1X4XH 14614 41/2 NIP14X412XH 14548 NIP38X412XH 14565 NIP12X412XH 14582 NIP34X412XH 14599 NIP1X412XH 14615 5 NIP14X5XH 14549 NIP38X5XH 14566 NIP12X5XH 14583 NIP34X5XH 14600 NIP1X5XH 14616 51/2 NIP14X512XH 14550 NIP38X512XH 14567 NIP12X512XH 14584 NIP34X512XH 14601 NIP1X512XH 14617 6 NIP14X6XH 14551 NIP38X6XH 14568 NIP12X6XH 14585 NIP34X6XH 14602 NIP1X6XH 14618 7 NIP34X7XH 14603 8 NIP34X8XH 14604 NIP1X8XH 14620 9 10 NIP34X10XH 203165 11 12 NIP34X12XH 203167 NIP1X12XH 14624
MFR# webb# MFR# webb# MFR# webb# MFR# webb# MFR# webb# Size 11/4” 11/2” 2” 21/2” 3”
CLOSE NIP114XCLOXH 14625 NIP112XCLOXH 14641 NIP2XCLOXH 14657 NIP212XCLOXH 14672 NIP3XCLOXH 14686 11/2 2 NIP114X2XH 14626 NIP112X2XH 14642 21/2 NIP114X212XH 14627 NIP112X212XH 14643 NIP2X212XH 14658 3 NIP114X3XH 14628 NIP112X3XH 14644 NIP2X3XH 14659 NIP212X3XH 14673 NIP3X3XH 14687 31/2 NIP114X312XH 14629 NIP112X312XH 14645 NIP2X312XH 14660 NIP212X312XH 14674 NIP3X312XH 14688 4 NIP114X4XH 14630 NIP112X4XH 14646 NIP2X4XH 14661 NIP212X4XH 14675 NIP3X4XH 14689 41/2 NIP114X412XH 14631 NIP112X412XH 14647 NIP2X412XH 14662 NIP212X412XH 14676 NIP3X412XH 14690 5 NIP114X5XH 14632 NIP112X5XH 14648 NIP2X5XH 14663 NIP212X5XH 14677 NIP3X5XH 14691 51/2 NIP114X512XH 14633 NIP112X512XH 14649 NIP2X512XH 14664 NIP212X512XH 14678 NIP3X512XH 152712 6 NIP114X6XH 14634 NIP112X6XH 14650 NIP2X6XH 14665 NIP212X6XH 14679 NIP3X6XH 14693 7 NIP114X7XH 14635 NIP112X7XH 225118 NIP2X7XH 14666 NIP212X7XH 210655 NIP3X7XH 192822 8 NIP114X8XH 14636 NIP112X8XH 14652 NIP2X8XH 14667 NIP212X8XH 110508 NIP3X8XH 192823 9 NIP114X9XH 225124 NIP112X9XH 223049 NIP2X9XH 187216 NIP3X9XH 187218 10 NIP114X10XH 187212 NIP112X10XH 223048 NIP2X10XH 14669 NIP3X11XH 187217 11 NIP2X11XH 187214 NIP3X12XH 14699 12 NIP114X12IXH 187213 NIP112X12XH 14656 NIP2X12XH 14671
Schedule 80 Nipples
concentric Swedge nipples XhMFR# DeScRiPTiOn webb#NIPCS1X34XH 1” X 3/4” Nipple Concentric Swedge 187219NIPCS114X1XH 11/4” X 1” Nipple Concentric Swedge 187220NIPCS112X114XH 11/2” X 11/4” Nipple Concentric Swedge 187221NIPCS2X114XH 2” X 11/4” Nipple Concentric Swedge 187222NIPCS2X112XH 2” X 11/2” Nipple Concentric Swedge 187223NIPCS3X2XH 3” X 2” Nipple Concentric Swedge 187224
eccentric Swedge nipples XhNIPES2X112XH 2” X 11/2” Nipple Eccentric Swedge 190099
Xh nipple Sets (1 of each)MFR# DeScRiPTiOn webb#NIP14XCLO-6XH 1/4” X CLOSE-6” Nipple Set Black XH 73366NIP38XCLO-6XH 3/8” X CLOSE-6” Nipple Set Black XH 73367NIP12XCLO-6XH 1/2” X CLOSE-6” Nipple Set Black XH 52875NIP34XCLO-6XH 3/4” X CLOSE-6” Nipple Set Black XH 52876NIP1XCLO-6XH 1” X CLOSE-6” Nipple Set Black XH 52877NIP114XCLO-6XH 11/4” X CLOSE-6” Nipple Set Black XH 93049NIP112XCLO-6XH 11/2” X CLOSE-6” Nipple Set Black XH 93050NIP2XCLO-6XH 2” X CLOSE-6” Nipple Set Black XH 93051
1/4” - 1”
11/4” - 3”
![Page 155: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/155.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Ga
s h
ea
tin
GIgnition Modules
149
8
8
SECTION
Gas Ignition ControlsUniversal Ignition ControlsRobertshaw’s Universal Ignition Control Uni-Kits feature a flame sense circuit that will work equally well on a one rod (local sense) or a two rod (remote sense) application.780-001 (Nonlockout)The automatic recycle features assure that, in the event of flame failure, main gas is disabled and the spark repetition sequence is restarted until pilot gas is ignited. Only after pilot ignition has been re-established can main gas be returned to the burner.780-002 (Lockout)These kits have a lockout feature to shut off all gas in the furnace, should pilot ignition fail to occur after a predetermined time period. The 780-002 provides 3 tries for ignition, each ignition period is 90 seconds followed by a 6 minute time delay between ignition attempts. After 3 tries if no pilot flame is sensed, unit goes into lockout and must be reset at the thermostat.
780-001
Mfr# descrIptIon webb#780-001 Non-Lockout 118693780-002 Lockout 75124
780 Series Hot Surface Ignition ModuleThe 780 Series Hot Surface Ignition Modules are designed for use on gas fired heating systems The system acts on a demand for heat by a switch or thermostat to supply power to the ignition control. On non pre-purge models, the ignitor will be energized immediately and remain on for wither of two optional selected ignitor heat-up time approximately 17 or 34 seconds. For models with the prepurge option, there is a time delay equal to the heat-up time selected before the ignitor is energized.
Mfr# descrIptIon webb#780-785 Gas Ignition Control 167059780-787 Gas Ignition Control 246666
780-910 Universal Hot Surface Ignition Module Uni-Kit®
The 780-910 Universal Hot Surface Ignition Module Uni-Kit is designed for use on gas fired systems. It is equipped with a self diagnostic green LED for quick troubleshooting. The LED indicates if the system is in normal operati on, has gone into lockout, has a weak flame signal, or has an internal error (a defective module).
Mfr# descrIptIon webb#780-910 Universal Hot Surface Ignition Module 155174
Test Equipment900-575 Module TesterThe 900-575 Test Kit is designed specifically for the professional service technician. Now an electronic ignition module — intermittent pilot, direct spark, hot surface can be quickly and accurately diagnosed at the job site. The 900-575 Tester will diagnose all the circuit functions on an I.C.U. Checking for proper sequence of operation and/or failure. No more guessing which part to replace. With the 900-575 change out the defective part the first time, not on a return call back.
Mfr# descrIptIon webb#900-575 Ignition Module Tester 152947720001W Quick Look Tester Q/L 360275900-575
780-910
780-785
![Page 156: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/156.jpg)
150 victormfg.com
Ignition Modules 8
Gas Equipment Catalog
SECTION
Replacement Controls and ComponentsIgnition Control Units780-015Add-on lockout module. Using the 780-015 module with 780-715 module will give application lockout timing function for use on LP gas, 60 second timing lockout on pilot and main gas flow.780-735Lockout Model. Flame rectification system. Use with gas valves 7000 BDER and 7100 DER. Has 60 second lockout timing.780-845Universal lockout model has three 90 second valve trials interrupted by a six minute purge cycle before 100% lockout.780-735
Mfr# descrIptIon webb#780-015 Non-LockoutFlameRectificationSystem —780-735 LockoutFlameRectificationSystem 73462780-845 Gas Ignition Control 167191
Automatic Pilot Relight KitsThe Robertshaw 785 Series automatic Pilot Relight Kits are designed for use on rooftop heating equipment, water heaters, boilers, space heaters, unit heaters, dryers, and other commercial, industrial, and residential appliances where the problem of pilot outage may occur. It should only be applied to those systems which already incorporate the necessary pilot-safety control system.
Mfr# descrIptIon webb#785-001 Automatic Pilot Relight Kit 79497
785-001
5059-23
50E47-150
Pilot Relite ControlThe relite control generates sparks until a pilot flame is sensed between the electrode and ground. When flame current is sensed between the electrode and pilot burner ground, the relite control stops sparking. If the flame is extinguished during the heat call, the relite control will begin sparking the instant the flame goes out.
Ignition Module for Hot Surface Ignition SystemsThe Hot Surface ignition Unit is a microprocessor based gas ignition control designed primarily for direct ignition and burner supervision applications such as gas furnaces, boilers, water heaters and other similar devices.
eLectrIcAL Mfr# InpUt VoLtAGe rAtInG descrIptIon webb#5059-23 24 VAC 0.03 Amps Spark Plug and 1/4” Spade Connectors 118717
Mfr#LockoUt
tIMe
IGnItor wArM-Up
tIMe
50e47 prepUrGe
tIMe (In seconds) webb#
50E41-843 4 Seconds 45 Seconds 0 Seconds 15258650E47-140
7 Seconds
17 Seconds30 Seconds
19297150E47-150
45 Seconds85263
50E47-170 0 Seconds 152586
![Page 157: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/157.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Ga
s h
ea
tin
GIgnition Modules
151
8
8
SECTION
Ignition ControlsG600, G670G600/G760 ignition controls are reliable, proven circuitry replacements for G60, G67 controls. In most cases the replacement controls have mounting configurations identical to the original device. Replacement controls feature precision timing for lockout models.Note: G600/G670 ignition control replacement parts must be used only for field replacement of existing equipment. These replacement parts must not be used for new field applications.
Universal Replacement Intermittent Pilot Ignition ControlG779The G779 Universal Replacement Intermittent Pilot ignition Control replaces many existing intermittent pilot controls made by various manufacturers. It is a safety control designed for indirect burner ignition and supervision. The G779 can be used with all gas-fired appliances with a maximum firing rate of 400,000 Btu/hr.
ApplicationsThe G779 replaces existing intermittent pilot ignition controls with the following specifications:• Flame detection using flame rectification technology (ability of a flame to conduct and rectify current).• Integral or remote flame sensing.• Non-100% lockout, 100% lockout, or 100% shutoff with continuous retry.• Trial for ignition period greater than or equal to 25 seconds.• Prepurge period less than 1 second.• Pilot burners with flow rates of 1,500 Btu-hr or less.• Operating with or without vent dampers.
The G779 is not designed to replace ignition controls with the following specifications:• Pilot flame detection by any means other than flame rectification.• Trial for ignition period of less than 25 seconds.• Prepurge period greater than or equal to 1 second.• Standing pilot applications.
Specifications
Operating voltage 24 VAC at 50/60 HzIgnition source High voltage spark, cap active dischargePrepurge Less than one secondNumber of trials before 100% shutoff OneTrial time for ignition 25 SecondsRetry delay period 5 MinutesFlame failure response time 0.8 SecondsType of gas Natural,LiquifiedPetroleum(LP),manufactured, mixed or LP gas-air mix
G779
G600
Mfr#100%
LockoUtdAMper
pLUG reMArks webb#G600AX-1C
NoYes 24 VAC, Terminal Bard Wiring 97579
G670AW-1C No 24 VAC, 1/4” Spade Wiring Connections 105895
Mfr# descrIptIon webb#G779LHA-1C Universal Intermittent Pilot Ignition Control 110805
![Page 158: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/158.jpg)
152 victormfg.com
Ignition Modules 8
Gas Equipment Catalog
SECTION
Spark IgnitorQ347Produces spark for direct ignition of main burner.• Includes inner Kanthal electrode with ceramic insulator,
bracket and Kanthal ground strap.• Use with S87C, D, K; S89E, F and Q354A.
Universal Intermittent Pilot ModuleS8610UField service replacement for most Honeywell, Robertshaw, Johnson, and UTEC (HSC) Intermittent Pilot Ignition Modules. Provides electronic control of most intermittent pilot ignition systems used on gas-fired furnaces, boilers, and other heating appliances.• Provides ignition sequence, flame monitoring and safety shutoff for intermittent pilot
central furnaces and heating appliances.• Provides 100 percent pilot gas shutoff if pilot fails to light; after 6-minute delay, trial for
ignition is repeated. Ignition trial/delay sequence is repeated until the appliance lights or call for heat is removed.
• For use in single rod of dual rod/remote sense applications.• Includes relay contacts for use with any intermittent pilot has control string with
maximum 1.0A pilot or 2.0A main valve rating; Honeywell VR8204, VR8304 or VR8345M combination gas control recommended.
Universal Hot Surface Ignition ModuleS8910UProvides operating control of a direct ignition system using a 120 Vac hot surface ignitor.• Provides easy field-replacement of a wide range of hot surface ignition modules
manufactured by Honeywell, Robertshaw, and White-Rodgers. Refer to the product specifications sheet for specific models that can be replaced by the S8910U.
• For 120 VAC (up to 5.0A) hot surface igniter (Norton 201/271 or equivalent).
The S8910U can be used only for direct replacement of specific installed models. Check the product specification sheet before replacing an existing hot surface module with the S8910U. If the existing module is not listed, do not use the S8910U to replace it. Always use the selection tab specified in the product specification sheet for the existing module being replaced. Replacement of an unlisted module or use of a selection tab other than specified can result in appliance malfunction.
S8610U3009
S8910U1000
Q347
Mfr# rod AnGLe webb#Q347A1004 Standard Orientation 188456
IGnItIon LockoUt IGnItIon trIALs Mfr# descrIptIon trIAL tIMe tIMInG to LockoUt webb#S8610U3009 IntermittentPilotControl ContinuousRetry 90Sec.Max. ContinuousRetry 74468
IGnItIon LockoUt IGnItIon trIALs Mfr# descrIptIon trIAL tIMe tIMInG to LockoUt webb#S8610U1000 Hot Surface Ignition Control 4 Sec. or 7 Sec. 4 Sec. or 7 Sec. 1 or 3 92054
![Page 159: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/159.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Ga
s h
ea
tin
GIgnition Modules
153
8
8
SECTION
Gas Ignition ModulesS89C Hot Surface Ignition ModuleProvide electronic control of 120V hot surface ignition systems used in furnaces, boilers and other heating appliances.• S89C is for systems with combination ignitor-sensor.• Use with Norton 201 Hot Surface Ignitors or equivalent.• Lockout after one trial for igniting if main burner fails to ignite.• Reset from thermostat after lockout.
Y8610U Universal Retrofit Intermittent Pilot Gas Burner ignition SystemsComplete kits converting conventional standing pilot system to intermittent pilot system. For use with 24 VAC gas-fired atmospheric furnaces, boiler and heating appliances.• Y8610U kits are for use with natural or LP gas; provides 100 percent pilot gas shutoff
if pilot fails to light; after 6-minute delay, trial for ignition is repeated.• Ignition trial/delay sequence is repeated until the appliance lights or call for heat
is removed.
S9200U1000 Universal Hot Surface Ignition Integrated Furnace ControlControls a standard induction-type circulating fan motor.• Main burner ignition using a 120V hot surface igniter. • Flame rectification circuit to monitor flame presence. • Monitoring of system pressure switch, high temperature limit, and rollout functions.• Appliance operation/safety requirements controlled via microprocessor. • Control of a standard induction-type circulating fan motor (based on appliance
requirements), in response to a conventional low voltage or EnviraCOM™ thermostat. • LED system status, performance and diagnostic indication. • Wire harnesses provided for simple replacement of most IFCs and integration with most
heating and cooling appliances. • Twinning capability • EnviraCOM™ communication capability to enable local and/or remote system status,
diagnostics, troubleshooting, and HVAC system control.
S89C
Y8610U
S9200U1000
Mfr# LockoUt tIMInG IGnItIon trIAL tIMe webb#S89C1087 6 Sec. 6 Sec. 95080S89C1095 15 Sec. 15 Sec. 152200
Mfr# IGnItIon seqUence typIcAL GAs controL GAs type webb#
Y8610U3003
ContinuousRetry(aftertrialforignition,
pilot gas shuts off for 5 minutes, then another trial for
pilotignitiontakesplace)
VR8304M Dual Valve Combination Gas Control LP/Natural 74467
Mfr#AMbIent teMp. (f)
pre-pUrGe
HsIwArMUp
tIMepost-pUrGe
HeAt on fAn deLAy
HeAt off fAn deLAy
cooL fAn on deLAy
cooL fAn off deLAy
GAs controL Used wItH webb#
S9200U1000 –40° F to +175° F
30 seconds
17/27 or 30/30
seconds15
seconds30 or 60 seconds
60, 90, 120, or 180
seconds5 seconds 0 or 60
seconds
Any24VACredundant, direct
ignition gas control rated at 1.5A or less. HoneywellVR8205
recommended.
372843
![Page 160: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/160.jpg)
154 victormfg.com
Gas Valves 8SECTION
Gas Equipment Catalog
Water HeatingDomestic, Commercial & Recreational Vehicle Water Heater Thermostat Uni-Kits®
110 SeriesThe 110-Series Water Heater Thermostat Uni-Kit® and Commercial Water Heater Thermostat Uni-Kit were designed for universal replacement applications. All models feature built-in, non- cycling Energy Cut-Off (ECO) system to shut off all gas to the water heater in case of excessive water temperatures. All models have a 51/2” sensing element and vary by inlet and outlet size, shank length, regulator type and setting.
Domestic and Commercial LP Gas Water Heater Thermostat Uni-Kits®
The 110 Series Water Heater Uni-Kits® are designed for universal replacement applications. All models feature built-in, non-cycling Energy Cut-Off (ECO) system to shut off all gas to the water heater in case of excessive water temperatures. All models have a 51/2” sensing element and vary by shank length.
700 (70000GO) Commercial700-800 Series bleed gas diaphragm valves feature: automatic pilot valve, bleed gas operator, inlet and outlet screens, manual “gas cock” valve, pilot adjusting key, pilot gas filter and pressure regulator (optional by model). Pressure Regulator Factory set at 3.5” W.C.
110-202
Gas Water Heater ControlsFor replacement of standard gas water heater controls with built-in E.C.O. (energy cut-off ).Features• Automatic shut-off of amin and pilot gas in the event of pilot failure.• Pilot gas cock with safe lighting feature.• Pilot gas filter.SpecificationsInlet Size: 1/2” NPTOutlet Size: 1/2” Inverted FlareMounting: 3/4” NPT, 11/4”, shank length, 41/2” bulb insertion lengthPilot Connection: 1/2” compression fitting
37C63U-114
Mfr# InLet sIze oUtLet sIzesHAnk
LenGtHpressUre
reGULAtor settInG webb#
110-202
1/2” Pipe 1/2” Inverted Flare
13/8” 4.0” W.C. Natural Gas 85376
110-206 23/8” 3.5” W.C. Natural Gas 246749
110-326 13/8” 3.5” W.C. Natural Gas 73452
Mfr#
InLet sIze (fpt)
oUtLet sIze (fpt)
pressUre reGULAtor
settInG cApAcIty
redUcer bUsHInGs IncLUded (npt)
3/4” x 1/2” webb#
700 “thermopile” type diaphragm Gas Valves
700-885 3/4” 3/4” None 305,000 2 186756
Mfr#teMp.
settInGInLet sIze
oUtLet sIze
sHAnk LenGtH
pressUre reGULAtor settInG webb#
Right Hand Thread — Outlet: Replaces Model RPL
110-262 160º 1/2” Pipe 1/2” Inverted Flare 13/8” Preset @10.0(Adjustable
from9”W.C.-12”W.C.) 73449
Left Hand Thread — Outlet: Replaces Model R65RR
110-265 160º1/2” Pipe
1/2” Inverted Flare(Lefthand
Threads)
13/8” Preset @10.0(Adjustablefrom9”W.C.-12”W.C.)
73450
110-285 180º 11/2” 75123
Mfr#MAIn
bUrner pILot teMp. rAnGesHAnk
LenGtH webb#
37C63U-114 3.5” W.C. Adjustable 70° F – 160º F 11/4” 188187
![Page 161: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/161.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Ga
s h
ea
tin
GGas Valves
155
8SECTION
8
4020 (FMDA) with Pilot Inlet and OutletThe 4020 Safety Pilot Valves provide gas shutoff in case of pilot outage. When the reset button is depressed, gas will flow to the pilot only. Main gas will not flow until the pilot is operating and the reset button has been released. Pilot inlet and outlet connections are 1/2”tubing, unless otherwise indicated. 100,000 BTU/HR capacity. Ambient Temperature 32° – 350°F.
Gas Oven Safeties1720 (TS) “J” and “K” Magnet HeadsThe 1720 Series Replacement Magnet Kit is used with 1710 Series Bodies in TS Automatic Safety Valve applications. All models have FLOW INTERRUPTION so that no gas can flow to the main burner while the reset button is depressed.1720 Series Kits are designed to replace many individual TS magnet types. Each magnet head kit is tapped for 1/8” pipe with fittings to adapt to 3/16” and 1/4” compression tubing. Also included: spring and diaphragm components, gasket and assembly screws.
Boxed ICON Direct Replacement Gas Controls and ValvesCan be utilized as a Direct Replacement on all Atmospheric Vent and Direct Vent Residential and Light Duty Bradford White ICON System™, Robertshaw or White Rodgers models up to 65 gallons* Includes: Pre-assembled ICON Gas Control Valve, Pilot Assembly, Feedline Spring, and Feedline adaptor.Residential Suffix Examples: Natural Gas (FBN, BN, LN, CN, EN) LP Gas (FSX, FCX, CX). Light Duty Commercial Suffix Examples: Natural Gas (FB-3N, B-3N, E3N) LP Gas (FS-3X, C-3X).
Boxed ICON Universal Replacement Gas Controls and ValvesCan be utilized as a Universal Replacement on all Atmospheric Vent and Direct Vent Residential and Light Duty Bradford White ICON System™, Robertshaw or White Rodgers models up to 65 gallons* Includes: Gas Control Cover, Gas Valve Body, 1” Thermowell, 2” Thermowell, 1” Insertion Stick, 2” Insertion Stick, Piezo Igniter, Temperature Sensor, Pilot Assembly, Feedline Spring, and Feedline adaptor.Residential Suffix Examples: Natural Gas (FBN, BN, LN, CN, EN) LP Gas (FSX, FCX, CX).Light Duty Commercial Suffix Examples: Natural Gas (FB-3N, B-3N, E3N) LP Gas (FS-3X, C-3X).
Mfr# descrIptIon pILot sIze webb#1720-801 GasOvenSafetyWithTubingKit–“J”Head 1/8” Pipe, 3/16” Tubing, 1/4” Tubing 751071720-802 GasOvenSafetyWithTubingKit–“K”Head 1/8” Pipe, 3/16” Tubing, 1/4” Tubing 85431
Mfr# descrIptIon webb#239-47463-01 Res.(160°F)DirectReplacementNat.ICONGasControlKit1”Cavity 420169239-47465-01 Res.(160°F)DirectReplacementLPICONGasControlKit1”Cavity 420168
Mfr# descrIptIon webb#239-47851-00 Res.(160°F)UniversalReplacementNat.ICONGasControlKit1”&2”Cavity 420167239-47856-00 Res.(160°F)UniversalReplacementLPICONGasControlKit1”&2”Cavity 420166
1720-801
4020-010Mfr#
MAIn bUrner pILot teMp. rAnGe webb#
4020-010 48”1/2” Pipe
11/64” 186656
4020-011 54” 15/64” 75110
![Page 162: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/162.jpg)
156 victormfg.com
Gas Valves 8SECTION
Gas Equipment Catalog
Gas ValvesPilot, Direct and Hot Surface Ignition700 SeriesThese 700 Series Gas Valve Uni-Kits® are designed for intermittent pilot, direct spark and hot surface applications. They incorporate a manual valve, pilot valve, and main gas pressure regulator. Each Uni-Kit includes all the necessary parts and instructions needed to convert to direct spark or hot surface applications.
700-506
700 MillivoltThe 700 millivolt gas valves are wall thermostat actuated combination gas valves. These controls combine a manual gas cock, automatic pilot safety valve and a millivolt operator. The automatic pilot safety is separate from the gas cock and provides gas shutoff in case of pilot outage. Standard features include: pilot outlet, pilot gas filter and pilot adjusting key. Valves can be mounted in any position except upside down.
700 Snap-Action and Snap-Throttle HydraulicThe 700-200 Series snap-action and snap-throttle (modulating) hydraulic controls are combination gas valves, thermostatically operated by a remote temperature sensing bulb.These controls combine a manual valve (gas cock), an automatic pilot safety valve, pressure regulator (optional by model) and a snap-acting or snap-throttle hydraulic operator for total temperature control. All models feature 3-position main gas outlets and pilot outlet, pilot gas filter, pilot adjustment key and automatic pilot valve.
700-201
Mfr#InLet sIze
(fpt)oUtLet
sIze (fpt)strAIGHt tHroUGH
pressUre reGULAtor
settInG cApAcIty webb#
Universal Models Intermittent Pilot, Direct Spark & Hot Surface
700-056 3/4” 3/8” — 3.5” Nat. Gas 350,000 85381
700-059 1” 1” — 4.0” Nat. Gas 720,000 167052
Mfr#
InLet sIze (fpt)
3 posItIon oUtLet
(fpt)cApILLAry
LenGtH
InternAL pressUre
reGULAtor settInG cApAcIty
redUcer bUsHInGs IncLUded
(npt) 1/2” x 3/8” webb#
Snap Action Models
700-201 1/2” 1/2” 36” None 100,000 2 73454
Snap Throttle Models
700-204 1/2” 1/2” 36” None 160,000 2 73455
700-205 1/2” 1/2” 36” 3.5” W.C.Nat. Gas 100,000 2 85383
Mfr#
InLet sIze (fpt)
strAIGHt tHroUGH
(fpt)
sIde (fpt) w/pLUGs
pressUre reGULAtor
settInG cApAcIty
3/4” x
1/2”
1/2” x
3/8” webb#
700-501 1/2” 1/2” 1/2” None 100,000 — 2 192864
700-502 1/2” 1/2” 1/2” 3.5” W.C. Nat. Gas 100,000 — 2 186752
700-503 1/2” 3/4” 1/2” None 240,000 1 — 94207
700-505 3/4” 3/4” Straight-Thru None 300,000 2 — 73457
700-506 3/4” 3/4” Straight-Thru 3.5” W.C. Nat. Gas 300,000 2 — 73458
700-507 1/2” 3/4” Straight-Thru 3.5” W.C. Nat. Gas 240,000 1 — 192865
Pool Heater Models
700-511 3/4” 3/4” Straight-Thru 3.5” W.C. Nat. Gas 300,000 2 — 193214
![Page 163: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/163.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Ga
s h
ea
tin
GGas Valves
157
8SECTION
8
Gas Valves (continued) 700 24 Volt Combination ValveThese valves feature a manual valve (gas cock), an automatic pilot safety valve, inlet/outlet screens, pilot outlet, pilot gas filter and pilot adjustment key.The automatic pilot safety valve is separate from the gas cock and provides gas shutoff in case of pilot outage. Valves can be mounted in any position except upside down.
700 Diaphragm/Solenoid ValvesThese controls are single function, diaphragm types and are excellent replacements for solenoid gas valves. Standard features include: pilot outlet, pilot gas filter and pilot adjustment key. Valves can be mounted in any position except upside down.
700 Line VoltageThese controls combine into one compact valve: a manual gas cock, automatic pilot safety valve and a silent line voltage operator. The automatic pilot valve is separate from the gas cock and provides gas shutoff in case of pilot outage. Valves can be mounted in any position except upside down.
700-406
705 Millivolt OperatorsThe 705 Series millivolt operator kit is designed to allow field conversion of 700 & 710 Series manual gas valves to wall thermostat control. These operators are also replacements for specific 700-500 Series gas valves.
Mfr#
InLet sIze (fpt)
3 posItIon oUtLetpressUre
reGULAtor settInG cApAcIty
redUcer bUsHInGs IncLUded
(npt) 3/4” x 1/2” webb#
strAIGHt tHrU (fpt)
sIde (fpt) wItH
pLUGs24 Volt Diaphragm Models – Have No Safety Magnet
700-417 1/2” 3/4” Straight-Thru None 300,000 2 118694700-422 1/2” 3/4” 1/2” 3.5” W.C.
Nat. Gas240,000 1 204528
700-424 3/4” 3/4” Straight-Thru 300,000 2 167053
Mfr#
InLet sIze (fpt)
3 posItIon oUtLetpressUre
reGULAtor settInG cApAcIty
redUcer bUsHInGs IncLUded
(npt) 3/4” x 1/2” webb#
strAIGHt tHrU (fpt)
sIde (fpt) wItH
pLUGs120 Volt Models
700-451 1/2” 3/4” 1/2” None 240,000 1 186750700-454 3/4” 3/4” Straight-Thru 3.5” W.C.
Nat. Gas 300,000 2 75115
Mfr#bLock coLor
pressUre sensItIVe settInG webb#
4020-010 48” None 192867
Mfr#
InLet sIze (fpt)
3 posItIon oUtLetpressUre
reGULAtor settInG cApAcIty
redUcer bUsHInGs IncLUded
(npt) 3/4” x 1/2” webb#
strAIGHt tHrU (fpt)
sIde (fpt) wItH
pLUGsSnap Action Models
700-400 1/2” 3/4” Straight-Thru Uni-Kit 240,000 1 186748700-401 1/2” 3/4” 1/2” None 240,000 1 79496700-402 1/2” 3/4” 1/2”
Uni-Kit240,000 1 192862
700-406 3/4” 3/4”
Straight-Thru
300,000 2 73456700-426 3/4” 3/4”
3.5” W.C. Nat. Gas
300,000 2 204405700-438 1” 1” 720,000 — —700-442 1” 1” 720,000 — 103214
![Page 164: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/164.jpg)
158 victormfg.com
Gas Valves 8SECTION
Gas Equipment Catalog
Gas Valves (continued) 710 Low Profile Gas Heating ValvesThe 710 low capacity gas heating valves are designed for recreational vehicles and other applications with limited space. All models include a manual valve (gas cock), automatic pilot safety valve, pilot outlet, pilot gas filter and pilot adjusting key. The control can be mounted in any position except upside down and all models have 3-position outlets.
710-203
720 Series Hot Surface Gas ValvesThe 720 Electronic Ignition Gas Valves are designed for a wide variety of heating applications. The valves incorporate a manual valve, dual automatic valves and a main gas regulator. Controls are multiposition and can be mounted in any position (except upside down).
720-079
720 Series Dual Valve Gas ControlsThe 720 Series Dual Valve Gas Controls are designed for a wide variety of heating applications and can be used to replace most constant pilot valves, including dual valve (six function) models.The 720 Series constant pilot gas valve is a six function valve incorporating the manual valve, safety shutoff magnet, dual automatic valves (hence the term dual valves”), main gas regulator, and pilot adjustment.
720-406
Mfr#
InLet sIze (fpt)
3 posItIon oUtLet
redUcer bUsHInGs IncL. (fpt)
cAp. LenGtH
pressUre reGULAtor
settInG AppLIcAtIon webb#Hydraulic Models — snap Action
710-2011/2” 1/2” (2)1/2” X 3/8”
18” None Recreational Vehicles
73459710-203
36”85422
710-205 3.5” W.C.Nat. Gas
Wall FurnacesReplaces TV-27 186764
24 Volt Models710-402 1/2” 1/2” (2)1/2” X 3/8” N/A 3.5” W.C.
Nat. GasWall Furnaces
12 VDC, 24 VAC 186765Millivolt Models Note:Usetwoleadthermoplilesonly.
710-501 1/2” 1/2” (2)1/2” X 3/8” N/A None Space HeatersReplaced B-67 94208
Mfr#InLet sIze
(fpt)oUtLet sIze
(fpt)strAIGHt
tHrU
sIde oUtLet 1/2” fpt
wItH pLUGs
pressUre reGULAtor
settInG cApAcItyredUcer bUsHInGs
webb#3/4” x 1/2” 1/2” x 3/8”720-400
1/2”3/4”
• — Uni IG150,000
1 — 167056720-401 • • None 1 — 73460720-402 • •
Uni IG1 — 167057
720-403 • • — 1 — 186770720-406 1/2” • — 150,000 2 — 73461
standing pilot Models — stop opening with convertible pressure regulator720-474 1/2” 1/2” • • • 150,000 — 1 186771
Mfr#InLet sIze
(fpt)oUtLet
sIze
sIde oUtLet 1/2” fpt wItH
pLUGs
pressUre reGULAtor
settInG cApAcIty webb#standard Model
720-051 1/2” 3/4” • Uni Kit 150,000 75113Universal Model — Intermittent pilot — direct spark — Hot surface
720-079 1/2” 3/4” — Uni Kit 150,000 90878
![Page 165: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/165.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Ga
s h
ea
tin
GGas Valves
159
8SECTION
8
Commercial Gas Thermostats4200 (FD) Body Type #2 and Body Type #3
4200 (FD) Body Type #1
Kits712 Series Intermittent Pilot Ignition Uni-Kits®
The Uni-Line 712 series pilot ignition system features flame rectification with solid-state logic and flame sensing to provide automatic sequencing that will ensure proper operation of an intermittent pilot ignition device. The 712 series pilot ignition system features quick and easy installation with complete in-depth instructions and trouble shooting information.
Uni-Kit
4200
Cycle-Pilot® Retrofit KitControl system designed to eliminate standing pilots by converting to cycle–pilot controls with automatic spark ignition. Gas valve functions are terminated on a printed circuit board that exits through the mercury flame sensor receptacle housing, on the terminal panel side.Features• Eliminates gas wasted by a standing pilot.• Eliminates pilot outage problems due to occasional drafts.• Each package contains the controls and hardware needed for conversion to
cycling pilot operation.• Uses existing pilot burner and wiring.21D18-3
packages Available
Specifications
Mfr#GAs
VALVeIGnItIon
UnIt descrIptIon webb#nonlockout Models — caution: Do not use on LP. Gas Applications
712-016 700-055 3/4” X 3/4”
780-715 (Nonlockout)
NaturalGasOnly—NonlockoutPressureregulatorisfactory-setat3.5”W.C.350,000BtuMax 189792
Mfr#body type
InLet sIde “f”
InLet reAr “H”
oUtLet sIde “e”
oUtLet sIde “G”
pILot oUtLet
cApILLAry LenGtH
MoUntInG posItIon
bULb sIze webb#
150° to 550° f (degrees)4200-025 Uni-IGI #2 3/8”
Pipe3/8” Pipe
3/8” Pipe
3/8” Pipe
Side&Rear 54” 4-Way 3/16”
Nickel —Low (200° f) to 550° f (degrees)
4200-026 Uni-IGI #2 3/8”
Pipe3/8” Pipe
3/8” Pipe
3/8” Pipe
Side&Rear 54” 4-Way
3/16” x143/4” Nickel
186688
Mfr#
InLet sIze (fpt)
InLet/oUtLet
sIze pILotcApILLAry
LenGtHMoUntInG posItIon bULb sIze webb#
4200-005 #2 1/2” Pipe Side 48” 4-Way 3/16” X 143/4” Nickel 186685
Mfr#
coIL VoLtAGe
60 HzeLectrIcAL
rAtInG
InLet/oUtLet
sIze
cApAcIty A.G.A.
stAndArd GAs GAs type webb#21D18-3 24 VAC 0.61 amps 3/4” X 3/4” 280,000 NaturalOnly 188186
Mfr#GAs
VALVesfLAMe
sensoreLectrode AsseMbLy
pILot reLIGHt
wIrInG HArness
21D18-3 38C84-426 3098-134 760-56 5059-23 F115-0084
![Page 166: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/166.jpg)
160 victormfg.com
Gas Valves 8SECTION
Gas Equipment Catalog
SmartValve™ SystemSV9501Combines gas flow control and electronic intermittent pilot sequencing functions into a single unit.• Suitable for a wide range of gas-fired appliances including residential furnaces,
roof-top furnaces, residential boilers, unit heaters, infrared heaters, space heaters and commercial cooking units
• Replaces SV9500, SV9501 and SV9502 control. See installation instructions for specific models. Ignition sequence includes timed trial for ignition.
Accessories
SV9501
Gas Valves,Electronic Single Stage — Standing PilotV800 Low Voltage Combination Gas ControlsProvide complete control of continuous pilot gas-fired central furnaces and boilers.• Include pilot flow adjustment screw.• Complete safety shutoff on pilot flame failure.• LITE-RITE (OFF-PILOT-ON) lighting sequence.
VR8200 Continuous Pilot Dual Automatic Valve Combination Gas ControlsCombination gas controls for use in 24 VAC gas-fired, standing pilot appliances with capacities from 20 to 200 cfh.• Controls include manual valve, two automatic operators, servo pressure regulator
and pilot adjustment.• Compact size.• Provide two automatic valves.• Solenoid-operated first automatic valve opens on thermostat call for heat; closes
when call for heat ends. Diaphragm-operated second automatic valve opens under control of regulator; closes if gas or power supply is interrupted.
• Meet codes requiring dual safety shutoff.• Standard and slow opening natural gas models include natural to LP gas conversion
kit; LP to natural gas conversion kit also available. LITE-RITE (OFF-PILOT-ON) lighting sequence.
• All adjustments, wiring connections and pilot outlet are accessible from top of control.• Adjustable servo regulator effectively maintains almost constant gas output pressure
under wide fluctuations in gas supply pressure.• Compatible with ECO connector.
V800
VR8200
Mfr# sIzeteMperAtUre
rAtInGs
pressUre reGULAtor
settInGpre-
pUrGeopenInG
cHArActerIstIcs webb#SV9501M2528 1/2” -40° F To 175° F 3.5” W.C. None Standard Opening 210277SV9502H2522 1/2” -40° F To 175° F 3.2” W.C. 15 Sec. SlowOpening 214000SV9602P4816 3/4” -40° F To 175° F 3.5” W.C. 30 Sec. Step Opening 424578
Mfr#type of
GAs
pressUre reGULAtor
settInG
InLet/oUtLet
sIze IncLUdes webb#
V800A1070 Natural Or LP 3.5” W.C.
3/4” X 3/4” One 3/4” X 1/2” ReducerBushings/Adapters 35054
V800A1088 1/2” X 3/4” Two3/4” X 1/2”, One 1/2” X 3/8” Reducer Bushings/Adapters 35055
Mfr#type
of GAs
pressUre reGULAtor
settInGInLet/oUtLet
sIzeopenInG
cHArActerIstIcs IncLUdes webb#
VR8200A2132 Natural 3.5” W.C. 1/2” X 1/2” Standard
1/2” X 3/8” Reducer Bushings; 38389014bagassembly-3/4” straight flangewithOringscrewsandwrench;
and 393891 Natural to LP Gas Conversion Kit
68950
Q3400A1024 Ignitors 15434339369 Natural to LP Conversion Kit 184601
![Page 167: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/167.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Ga
s h
ea
tin
GGas Valves
161
8SECTION
8
Gas Valves, Electronic Single Stage — Intermittent PilotVR8204 Intermittent Pilot Dual Automatic Valve Combination Gas ControlsCombination gas control for use in 24 VAC gas-fired intermitent pilot appliances with capacities from 20 to 200 cfh.• Controls include manual valve, two automatic operators, servo pressure regulator
and pilot adjustment.• Use with S86F,H; S8600F,H and S8610 Control Modules.• Compact size.• Provide two automatic valves.• Solenoid-operated first automatic valve opens on thermostat call for heat;
closes when call for heat ends. Diaphragm-operated second automatic valve opens under control of regulator; closes if gas or power supply is interrupted.
• Meet codes requiring dual safety shutoff.• Standard and slow opening natural gas models include natural to LP gas conversion
kit; LP to natural gas conversion kit also available.• All adjustments, wiring connections and pilot outlet are accessible from top of control.• ON-OFF lighting sequence.
VR8204
Gas Valves, Electronic Single Stage — Standing PilotVR8300 Continuous Pilot Dual Automatic Valve Combination Gas ControlCombination gas control for use in 24 VAC gas-fired standing pilot appliances with capacities from 30 to 300 cfh.• Controls include safety shutoff, manual valve, two automatic operators,
pressure regulator and pilot adjustment.• Compact size.• Provide two automatic valves.• Solenoid-operated first automatic valve opens on thermostat call for heat; closes
when call for heat ends. Diaphragm-operated second automatic valve opens under control of regulator; closes if gas or power supply is interrupted.
• Meet codes requiring dual safety shutoff.• Standard and slow opening natural gas models include natural to LP gas conversion
kit; LP to natural gas conversion kit also available.• All adjustments, wiring connections and pilot outlet are accessible from top of control.• Adjustable servo regulator effectively maintains almost constant gas output
pressure under wide fluctuations in gas supply pressure.• Compatible with ECO connector.• LITE-RITE (OFF-PILOT-ON) lighting sequence.
VR8300
Mfr#teMperAtUre
rAtInGs
pressUre reGULAtor
settInG
InLet/oUtLet
sIze
openInG cHArActer-
IstIcs IncLUdes webb#
VR8204A2076 -18° F to +79° F 3.5” W.C. 1/2” X 1/2” Standard
3/4” X 3/8” Reducer Bushing 393691
Natural to LP Gas Conversion Kit
76221
Mfr#
pressUre reGULAtor
settInG
InLet/oUtLet
sIze IncLUdes webb#
VR8300A4516 3.5” W.C. 3/4” X 3/4”Two3/4” X 1/2” Reducer Bushings; 383200EOO adapter,
Q340(36”)thermocouplewithadapters, 393691 Natural to LP Gas Conversion Kit
86743
![Page 168: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/168.jpg)
162 victormfg.com
Gas Valves 8SECTION
Gas Equipment Catalog
Gas Valves, Electronic Single Stage— Direct IgnitionVR8345 Universal Electronic Ignition Combination Gas ControlUniversal electronic ignition combination gas control for use with direct spark ignition, hot surface ignition or intermittent pilot ignition in 24 VAC, gas-fired appliances, with capacities from 30 to 415 cfh.• Control includes manual valve, two automatic operators, pressure regular,
pilot adjustment, pilot plug and ignition adapter.• Replaces virtually any IP, HSI, or DSI gas control.• For use with natural or manufactured gas or LP gas. Includes converter kit to adapt
from natural to LP gas.• Compact size.• All adjustments and wiring connections accessible from top of control.• Four-inch swing radius allows easy rotation into position inside the tightest
furnace vestibules. • Clearly marked, keyed terminal block allows quick attachment of wires and IP/DSI/
HSI jumper.• Internal inlet screen blocks contaminants in gas line from entering valve.VR8345
VS830
Gas Valves, MillivoltVS830 Millivoltage Combination Gas ControlsProvide complete control of continuous pilot gas-fired central furnaces and boilers.• Include pilot flow adjustment screw.• Easy to install, adjust and service; all adjustments and connections are accessible
from top of control.• Add separate energy cutoff (ECO) where codes call for dual safety shutoff.• Complete safety shutoff on pilot flame failure.• LITE-RITE (OFF-PILOT-ON) lighting sequence.• ECO connector for V800 models. Part No. 392451-1.
Mfr#
InLet/oUtLet
sIze
pressUre reGULAtor
settInGtype
of GAs IncLUdes webb#
VR8345M4302 3/4” X 3/4” 3.5” W.C. Natural Two3/4” X 1/2” NPT Reducer Bush-ings and one 1/2” X 3/4” NPT Bushing 93587
Mfr# InLet/oUtLet sIzepressUre
reGULAtor settInG type of GAs webb#
VR820A1047 1/2” X 3/4”3.5” W.C. Natural
35056
VR820A1054 3/4” X 3/4” 35057
![Page 169: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/169.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Ga
s h
ea
tin
Gthermocouple & thermopile Generators
163
8SECTION
8
Thermocouples and Pilots1950 & 1951 ThermopilesThe 1950 and 1951 Thermopiles (pilot generators) are designed for use on self-positioned gas control systems.
1970 Uni-Couples 20 to 30 MillivoltsThe 1970 Series Uni-Couples unique design allows for installation to virtually all pilot burners. The versatile zip nut may be pushed, pulled or threaded onto the thermo-couple’s rolled threads for proper positioning in every application. The stainless steel tip (longer life), extended cold junction (greater voltage output potential), copper tube (corrosion protection with low electrical resistance), and lock washer equipped coaxial connection (resists loosening due to vibration or changes in ambient temperature) make the Uni-Couple the single most versatile thermocouple available today.
1980 Snap-Fit ThermocouplesThe 1980 Series Snap-Fit Thermocouples offer easy installation into the majority of pilot burners. Both slim and standard thermocouple types are available in the 1980 Series without complicated adapters, but with the extra insulation from high ambient temperatures that the brass sheath offers when needed. The 1980 is constructed of the same materials as used in the 1970.
1960-027 Low Mass ThermocoupleThe 1960-027 is a special low-mass or quick dropout thermocouple. It is usually found on applications that require an oxygen depletion system on the thermo safety. Also found on many L.P. gas applications that require a quick dropout of the thermo safety if there is a loss of pilot flame.Note: Has standard thermocouple threads. Will not fit applications with metric threads.
Replacement PartsThermocouple Test AdapterAdapter to test thermocouple and thermopile closed circuit.
Shank ExtensionIncreases length of 11/4” and 13/8” shank models to approximately 3”.
Junction Block AdapterThe 1922-001 adapter allows the high limit switch to be connected into the thermocouple cicuit on valves without the slotted magnet.
Mfr# descrIptIon webb#10-238 Thermocouple Test Adapter 167043
Mfr# LenGtH webb#1970-018 18” 1671881970-024 24” 1671891970-030 30” 1671901970-036 36” 853751970-048 48” 1551701970-060 60” 1866441970-072 72” 85441
Mfr# LenGtH webb#1960-027 27” 217093
Mfr# LenGtH webb#1980-018 18” 734701980-024 24” 734711980-030 30” 1866451980-036 36” 734721980-048 48” 1525961980-060 60” 734731980-072 72” 188181
Mfr# descrIptIon webb#10-250 Shank Extension 80696
Mfr# descrIptIon webb#1922-001 JunctionBoxAdapter 75109Y99AN-1H JunctionBlockAdapter 178174
1950-0011950-0021950-0031950-5321950-5481951-0011951-536
Mfr# LenGtHIncLUdes pG9
pILot AdApterconnectIon
type webb#36”48”60”36”48”36”36”
8264219406518664019284818664173469111602
•••
——•
—
TwoLead
Coaxial
Y99AN-1H
1922-001
![Page 170: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/170.jpg)
164 victormfg.com
thermocouples & thermopile Generators 8SECTION
Gas Equipment Catalog
Replacement Thermopile GeneratorsQ313Provide power for millivoltage, self-powered control systems.• Eliminate the need for outside
power source.• Easy push-in installation.• Include spade terminals.• Individually skin packed,
each unit ordered represents one thermopile generator.
Universal 30 mV ThermocoupleQ340There is a Q340 for every gas-fired heating system application.• Replace almost any 30 mV thermocouple.• Average operating life of ten years.• Available in a variety of lead lengths.
Q340A1066Q340A1074Q340A1082Q340A1090Q340A1108
Mfr# LenGtH (In) webb#
18”24”30”36”48”
3087630877308783087986216
K19AT-18HK19AT-24HK19AT-30HK19AT-36HK19AT-48HK19AT-60H
Mfr# LenGtH (In) type webb#
182430364860
183569183570183571152513155142183574
“SuperSlimJim”
Standard BASO® ThermocoupleK15 SeriesThe K15 Series Thermocouples are designed for use in standing pilot ignition systems. They are used primarily with BASO brand automatic pilot controls and pilot burners.K15DS models are standard thermocouples. K15FS models are snap-on thermocouples that allow for fast, easy assembly. The K15WS model is a wholesale thermocouple that is supplied with additional fittings.
“Husky” High Performance ThermocoupleK16 SeriesThe K16 Series are heavy-duty, high performance thermocouples that provide high output for residential, commercial, and industrial applications. The “Husky” is a replacement for BASO 17D, 50, 58D, 87D, 88D, 97D, 107D, and K15DA thermocouples. The K16 is packed with adapters to allow the necessary replacement. K16BT models are standard thermocouples. K16RA models are nickel plated thermocouples. K16WT models are wholesale thermocouples that are supplied with additional fittings.
K16BT-18HK16BT-24HK16BT-30HK16BT-36HK16RA-60CK16WT-48H
Mfr# LenGtH (In) type webb#
182430366048
18356415251118356596960194088183568
“Husky”
“Husky”NickelPlated“Husky”WithFittings
K15DS-18HK15DS-24HK15DS-30HK15DS-36HK15FS-24HK15FS-36HK15WS-48H
Mfr# LenGtH(In) type webb#
18243036243648
184577183556183557184579183561183562183563
Standard BASO
Snap in BASO
Standard BASO With Fittings
Mfr# resIstAnce IncLUdesLeAd
LenGtH webb#1/2” thermopile attaching nutPush-in clipPG9 adapter(part#393948)
Push-in clip, 1/2” thermopile attaching nut
Includesjunctionbox for series
hookupwithhighlimitswitch
Q313A1055 47” 2.90 ohm 188174
Q313A1139 83335
Q313A1170 85874
Q313A1188 35” 2.89 ohm 84659
Q313B1005 86741
“Super Slim Jim™” Universal Replacement Thermocouples
![Page 171: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/171.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Ga
s h
ea
tin
GPilot Burner & Orifices
165
8SECTION
8
Gauging Drill Kit — GDK4080Plastic box contains 41 drill sizes: #40 – 80, and GB3020H tapered broach.
Anderson & Forrester Inc.
Mfr# descrIptIon webb#ANFGDK4080 Gauging Drill Kit 188739
Tapered Broach — GB3015Three cornered broach. Tapered from .003” to .013”. A must for cleaning Pilot Orifices.
Mfr# descrIptIon webb#ANFGB3015 Three Cornered Broach 180504
Master Pilot Orifice Assortment Kit — MIK132LPIn one kit you now have 32 of the most needed pilot orifices with over 100 pieces. These are replacement pilot orifices for Penn Baso, Robertshaw, General Controls, Honeywell and White-Rodgers. A must for every efficient serviceman. Cabinet is made of heavy gauge steel with durable baked enamel finish and radius bottom sections for easy removal.Mfr# descrIptIon webb#ANFMI132LP PilotOrificeAssortmentKit 180534
Master Adapter Kit — MIK100Includes all tools needed to assemble MI100 adapters.Mfr# descrIptIon webb#ANFMIK100 Master Adapter Kit 180533ANFMI100 Universal Adapter 180532
Serviceman’s Friend — TL051For use with flow meter and other applications. One end of fitting has 1/8” pipe thread, 1/4” pipe thread and special 5/16” X 32 thread. Opposite end has regular hose fitting, also 1/8” straight pipe thread. Hose can be used on either end.
Gauging Reamer Kit — GRK5000Have the correct size reamer when you need it. Our kit contains each size in a slim plastic case.Mfr# descrIptIon webb#ANFGRK5000 Gauging Reamer Kit 180593ANFGR5070 Gauging Reamer, #70, 5 Pack 180602ANFGR5080 Gauging Reamer, #80 180598
Serviceman’s Orifice Assortment Kit — MIK131LPThe MIK131 orifice cabinet contains 23 of those orifices most commonly used. Over 300 orifices in proportion to normal demand.
Mfr# descrIptIon webb#ANFTL051 Serviceman’s Friend 180578
Mfr# descrIptIon webb#ANFMIK131LP OrificeAssortment 188738
Gauging Drill Kit
Tapered Broach
Gauging Reamer Kit
Master Adapter Kit
Master Orifice Kit
Serviceman’s Orifice Kit
Serviceman’s Friend
![Page 172: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/172.jpg)
166 victormfg.com
Pilot Burner & Orifices 8SECTION
Gas Equipment Catalog
Compression FittingsBreak-away type separates upon tightening.
Mfr# descrIptIon webb#ANFCF639 1/8”ShortBreakawayNut 180414ANFCF640 3/16”ShortBreakawayNut 180415ANFCF641 1/4”ShortBreakawayNut 180388HON386449-1 1/4”BreakawayNut 102371ANFCF642 1/4”MediumBreakawayNut 180599EMPR1633-2 1/8”LongBreakawayNut 181653HON386449-4 1/4”LongBreakawayNut 223431
EMPR2972 1/4”LongBreakawayNut 181654EMPR1633-4-2 1/4” X 1/8”LongBreakawayNut 181653
RBS4590-065 1/8”ShortBreakawayNut 93031RBS4590-067 3/16”ShortBreakawayNut 93030RBS4590-069 1/4”ShortBreakawayNut 93028RBS4590-071 3/8”ShortBreakawayNut 186719RBS4590-072 7/16”ShortBreakawayNut 189070
Anderson & Forrester Inc.
Gas Orifices & Gauging Drills (continued)
Orifice Caps
Mfr# descrIptIon webb#ANFCO400-72 LP, 1/2” Hex, 3/8-40 UNS 180416ANFCO401 Blank, 1/2” Hex, 1/2-27 NPT 180419ANFCO403 Bored, 1/2” Hex, 3/8-27 UNS 180421ANFCO404 Blank, 9/16” Hex, 1/2-27 UNS 180422ANFCO406 Blank, 1/2” Hex, 3/8-27 UNS 180424
Orifice Hex Plugs
Mfr# descrIptIon webb#ANFPO505 Blank, 1/2” Hex, 1/8-27 NPT 180541ANFPO508 Blank, 1/4” Hex, 1/4-28 UNF 180544ANFPO511 Blank, 1/2” Hex, 7/16-27 UNS 180546ANFPO518 Blank, 3/8” Round, 11/32-32 Special 180549
Mfr# GAs type tUbe sIze orIfIce sIze webb#10-030 LP 1/4” or 3/16” .010 18659810-261 LP 1/4” .0088 186605
pILot GAs tUbe orIfIce Mfr# UsAGe type sIze sIze webb#10-066 #70G Nat. 3/16” .018 —10-043 #70G Nat.&L.P. 3/16” .014 8538710-045 #40A L.P. 3/16” .013 186600
Replacement Parts & Accessories
Pilot Orifices
Pilot TubeJust bend and cut to length! Keep a few on your truck to take care of clogged pilots! 3/16” pilot tube, 17” long with 4 port orifice hood.
Mfr# descrIptIon webb#10-383 3/16” X 17” Pilot Tube 189026
Aluminum TubingA full range of diameter sizes in 50’ lengths, and for convenience, 5’ lengths with fittings.
Mfr# o.d. sIze LenGtH webb#11-016 7/16” 5’ 9420411-017 3/8” 5’ 15517211-191 1/8” 50’ 15338011-193 1/4” 50’ 15517111-195 3/8” 50’ 15517311-291 1/8” 5’ 21278911-292 3/16” 5’ 7344211-293 1/4” 5’ 73443
10-04310-04510-066
10-028 10-261
![Page 173: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/173.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Ga
s h
ea
tin
GPilot Burner & Orifices
167
8SECTION
8
Pilot BurnerQ314Nonprimary-aerated, insert orifice type pilot burner for main burner ignition with Q340 or Q390 Thermocouple for Pilotstat safety control operation.• Use with Q313 Thermopile Generator for 750 mV powerpile applications.
Q314
Q327Primary-aerated, spud orifice-type pilot burner for main burner ignition with Q340 or Q390 Thermocouple for Pilotstat safety control operation.• Use with Q313 Thermopile Generator for 750 mV powerpile applications.
Q345Nonprimary-aerated, combination pilot burner and ignitor. Used with the S86, S8610, or S8670 in intermittent pilot systems.• Includes pilot burner with bracket, ceramic-insulated Kanthal flame
rod/spark ignitor and ground strap.
Q345A
Q347
Combination Type Pilot BurnerThe J991MDA-2 through J999MDA-2 models are universal replacement pilot burners for J10(-)DDA, J11(-)DDA (D10and D11) types.The pilot burners are individually packaged in a plastic bag. 10 bags per carton.
Multi-Mount Universal Pilot BurnerThe J Series BASO universal replacement pilot burners are supplied in three models. Mounting brackets on all four sides of each burner permit adaptation to almost any application.The pilot burners are individually packed in a plastic bag. 10 bags per carton.• Three tapped holes in each bracket for vertical adjustment.• Natural and LP gas orifice supplied.• Nuts and bolts furnished in each package.
#2#7
#8 #9
J999MHA-2 J999MKA-2
J999MYA-2
Q314A4586Q314A6094Q314A4585
LP; Natural BFrontLeft
Right
Mfr# type of GAsMoUntInGbrAcket
dIrectIon of front tIp webb#
8063586742
—
Q345A1305Q345A1313
Mfr# dIrectIon of front tIp type of GAs webb#
FrontLeft
Natural 152195152196
J992MDA-2HJ997MDA-2HJ998MDA-2HJ999MDA-2H
Mfr# tIp posItIon nAtUrAL GAs orIfIce Lp GAs orIfIce webb#
2789
Y90AA-3223Y90AA-3221Y90AA-3223Y90AA-3223
Y90AA-4213Y90AA-4211Y90AA-4212Y90AA-4212
183617118696118697183554
J999MHA-2HJ999MKA-2HJ999MYA-211
Mfr# type of pILot nAtUrAL GAs orIfIce Lp GAs orIfIce webb#
“L”ChannelShell
“Y”Channel
Y90AA-7223Y90AA-7221Y90AA-6221
Y90AA-4211Y90AA-4210Y90AA-4211
—118699183620
Mfr# descrIptIon type of GAs webb#
Q327A1626 Bat Wing LP; Natural 88371
![Page 174: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/174.jpg)
168 victormfg.com
Pilot Burner & Orifices 8SECTION
Gas Equipment Catalog
Gas Ignition ControlsReplacement SensorsMfr# descrIptIon webb#10-277 S1 Sensor has 1/4” quick-connect terminal 203364
Pilot Kits1810-100 Universal 2BLC Pilot Uni-Kit®
Mfr# descrIptIon webb#1810-100 Universal Pilot Uni-Kit 87067
The 1810-100 Universal 2 BLC Pilot Uni-Kit is designed to replace the obsolete Model 2B/2BLC Pilot which is no longer in production. The kit includes fittings for 1/4” tubing and an adapter and f ittings to adapt to 3/16” tubing. Each kit comes with a Natural gas orifice installed and includes a separate L.P. gas orifice.
1820 Series PG9 Replacement Pilot Uni-Kits®
The 1820 Series UniKits are designed to replace those hard-to-find ITT-General PG9 type pilots. Each Uni-Kit come with a natrual gas orifice installed and a separate L.P. gas orifice. A special 1/4” tubing adapter is provided that allows use of original tubing with nut and ball sleeve.
1830 (2CH & 2C) Incinerator-Target Pilot Uni-Kits®
The 1930 Series Pilot Uni-Kit is designed to be used with all Uni-Line and competithive thermocouples. Kits include an adaptor that converts a threaded thermocouple/thermopile model 2CH to a snap-in thermocouple type model 2C. Each kit comes with a natural gas orifice installed, and a separate L.P. gas orifice.
1830-700 Pilot Electrode SeriesThe 1830-700 Series Pilot Uni-Kits are designed for use with the O.E.M. style Pilot Ignition Systems. The electrode is permanently riveted to the pilot frame and the spark gap is fixed at 1/8”. These pilots can be used to replace existing pilot assemblies or when retrofitting standing pilot applications when and exact replacement is desired. Each Uni-Kit comes with a natural gas orifice installed and a separate L.P. gas orifice. Pilot tubing size is 1/4”.
1850/1851 Mini Pilot 100’sMini-Pilot 100’s are nonaerated (no primary air) and can be used on all gases with no orifice change. The pilots are position- sensitive and care should be taken to install them in their correct position. (TOP stamped into casting at top when applied).
1890-100 (#11) Pilot Uni-Kit®
The 1890-100 Pilot Uni-Kit includes fittings for 1/4” tubing and an adapter and fittings to adapt to 3/16” tubing. The kit comes with a Natural gas orifice instlled and includes a separate L.P. gas orifice.
Mfr# descrIptIon webb#1890-100 36”Mini-Pilot,Type#6 167187
1898 Series Pilots1898 Series Pilots are used with 4060 (MSA and MSC) Series Safety Valves. Suitable for natural or L.P. gas using the .14 universal orifice.
Mfr#
fLAMe pAttern
(deGrees)type
of GAswItH
tHerMopILe webb#1820-009 90 Right Natural and
L.P. Gas Orificies Included
• 1866171820-019 90 Left • 1866181820-029 90 Right
PilotOnly 751161820-039 90 Left —
Mfr#tUbe
LenGtHInLet sIze (tUbInG) webb#
Horizontal Angle Type #2 Kit1851-051 24”
3/16”&1/4” 1928441851-052 36” 192845Horizontal Angle Type #4 Kit1851-152 36” 3/16”&1/4” 192847Vertical Bottom Inlet Type #6 Kit1851-252 24”
3/16”&1/4” 1670461851-253 36” 85438
Mfr#fLAMe pAttern
typeLeAd
LenGtH webb#1890-705 Standard 24” —
Mfr# tUbInG sIze tUbInG sIze webb#1890-022 3/16” .14 —
Mfr#Hood type
MoUntInG brAcket
typefLAMe
pAttern type webb#1830-001 2
6
Standard 751181830-002
590 Degrees Left 111048
1830-003 90 Degrees Right 1667841830-004 2 25 Degrees Left 1890321830-005
43-Way(A) 111049
1830-011 4 3-Way(C) 853991830-013 5 7 90 Degrees Left 1525951830-015 3 4
Standard 1866221830-210 2
2 751191830-213 4 3-Way(A) 854341830-489 6 6 3-Way(B) 192842
![Page 175: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/175.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Ga
s h
ea
tin
Gregulators
169
8SECTION
8
Gas Valves1751 Add-On Pressure Regulator KitsThe 1751 Series Add-on pressure regulator kits are available for use on the following factory model types; 7000, 7010, 7100, 7200 & 7222.
1751-003
4080 Pressure RegulatorsThe 4080 Series Pressure Regulators are designed for main burner and pilot duty applications. The regulator is convertible with settings at 4” W.C. Natural gas and 10” W.C. L.P. gas on the 4080-032 and 4080-035.
4080-035
Mfr# reGULAtor typesUItAbLe for
webb#nAt. GAs L.p. GAs1721-003 3.5” W.C. Nat. Gas — — 854061751-007 Regulator Cover Plate — — 192839
Mfr# pIpe sIze reGULAtor type sUItAbLe for webb#4080-035 3/4” X 3/4” 4”(Fixed)W.C.NaturalGas
10”(Fixed)W.C.L.P.Gas Nat. Gas 73478
Mercury Flame SensorsThe Mercury Flame Sensor is a mechanical device that provides the existence of an acceptable pilot flame. When the bulb is heated by a pilot flame, the mercury is vaporized, causing pressure in the capillary and diaphragm, causing the snap-switch to open one set of contacts, and close a second set. These contacts control the pilot valve and the main valve.
3098-134
Mfr#eLeMent LenGtH
pAneL type
bULb styLe descrIptIon webb#
3098-134 48” E #19 ReplacesBulbStyles#9or#13. 1187113098-156 #20 ReplacesBulbStyles#17or#18. 205641
![Page 176: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/176.jpg)
170 victormfg.com
Hot surface Ignitors 8SECTION
Gas Equipment Catalog
Gas Ignition Controls
41-401
41-402
41-403
41-406
41-405
41-404
41-407 41-408
41-409 41-410
41-41141-412
41-600 Series Hot Surface Furnace Mini-IgnitorsRobertshaw’s 41-600 Series Norton Hot Surface Mini-Ignitors deliver dependable ignition heating systems of every description. All Norton ignitors are engineered for easy handling, simple installation and trouble-free operation.
41-602
41-605
41-400 Series Hot Surface Furnace IgnitorsRobertshaw’s 41-400 Series Norton Hot Surface Ignitors deliver dependable ignition heating systems of every description. From furnaces and boilers to rooftop heaters, infrared burners, unit heaters, water heaters and many other types of HVAC equipment.The 41-400 Series Hot Surface Ignitors are made of high-purity recrystallized silicon carbide (Crystar™) which combines physical and thermal strength with stable electrical properties. The 41-400 Series are designed to reach ignition temperature(s) within 17 seconds. They have 8-gauge nickel chrome lead wires embedded and metalized in place for maximum holding strength and electrical conductivity. The lead wires are also enclosed with a special high-temperature fiberglass insulation providing total electrical protection.
Mfr#fActoryModeL
LeAd wIre LenGtH webb#
41-401 271A 41/2” 7344441-402 271W 19” 7344541-403 271M 51/2” 7344641-404 41/2” 11033041-405 271D 51/2” 11161741-406 271Y 101/2” 7344741-407 271
41/2”
11106141-408 271N 15338241-409 271 8069741-410 271N 11161841-411 11161941-412 271NM 51/2” 11162041-413 201C 13/8” 189061
Mfr#fActoryModeL
HoUsInG LenGtH coMMents webb#
41-602 601TB None Amana #20165702 25035341-604 601XBM 4” Armstrong #44744-2 24129141-605 601XBM +
Harness&Brackets 2.5” York Replacement Conversion Kit #473-20937-001 241292
![Page 177: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/177.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Ga
s h
ea
tin
GHot surface Ignitors
171
8SECTION
8
GlowFly Ignitor
Hot Surface IgnitorIgniters Direct are a durable universal direct upgrade for replacing most silicon carbide igniters.
The Q3200U Universal Hot Surface Igniter Kit is designed to provide a robust field service replacement igniter in gas fired appliances with Norton/St Gobain 120 VAC silicon carbide hot surface igniters. The Q3200U uses a 120 volt silicon nitride igniter design with long life and high resistance to damage or burn out in the appliance. The kit includes the specially designed silicon nitride igniter and six different bracket configurations to adapt the igniter to the specific appliance application along with accessory parts to allow mounting and wiring the igniter. Clear instructions and application templates are provided to simplify selection of the proper bracket and ease installation of the replacement.
Mfr# coMMents webb#URK24V 24V Hot Surface Igniter 309804URK120VF 120V Flat Universal Kit 268458URK120VR 120V Round Ignitor Kit 401572
Mfr# descrIptIon webb#HONQ3200U1004 GLOWFLY UNIV HOT SUR IGNITOR 417300HONQ3200U2002 GLOWFLYUNIVHOTSURIGNITOR(6PC) 417299
USeD IN SMARTVALVe™ RePLAceS IgNITeR FLAMe SySTeMS INcLUDINg: ROD ASSeMBLy INcLUDINg:SV9500 1009524SV9500M2603 1149856SV9500M2674 42640001SV9500M2682 CARQ3400A1024SV9500M-2682 Q3400ASV9501M2528 Q3400A1016SV9600 Q3400A1024SV9600H Q3400A1040SV9401 Q3450SV9402 Q3480SV9403 Q3620SV9501 SV9502 SV9503 SV9601 SV9602
Ignitors Replaced by URK24VThe smart-lite™ igniter flame rod assembly is a direct replacement for all 24 volt hot surface igniter SmartValve™ systems and includes equipment made by AO Smith, Armstrong Furnace, Bradford White, Ducane and Skymark.
![Page 178: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/178.jpg)
172 victormfg.com
Hot surface Ignitors 8SECTION
Gas Equipment Catalog
MANUFAcTUReR PART NUMBeRAmerican Road Equip 201WAcro Air 1096048 | 1380680Armstrong Air 38322B001Carrier Corporation LH33ZS001A | LH33ZS002Claire Brothers C-238 | C-242Coleman 1474-051 | 1474-052Comfort Maker 1096048Detroit Radiant 201DDMO Industries 20834Dornback Furnace 271WDucane 20015201Enerco Tech 10399Evcon 1474-051 | 1474-052Goodman B10401009Heil 1096048Hupp Industries 9050Intercity 1009604|1096048Majestic 75-92-104|75-92-105Metzger 201N | 201WMor-Flo 3200618Nordyne 105141000|632-0770|632-0880|902661|902694|903110|FC007Norton 201 | 201D | 201K | 201L | 201R | 201W | 271 | 271D | 271M | 271N | 271NM | 271P | 271WRaypak 600915Rheem 62-22441-01 | 62-22868-82 | 62-22868-93Roberts Gordon 90434300 | 90436600Robertshaw 41-402|41-403|41-404|41-405|41-407|41-408|41-409|41-410|41-411|41-412|41-414Smith HB 50018SnyderGeneral 1380654|1380672|1380680Superior Fireplace 94851Tempstar 1096048 | 1148245TraneCompany 340039P01|B138196P01|B144676P01|B144676P02|B340039P01|IGN21|IGN23|IGN26|IGN30Viessman 9302-094WayneHomeEquip 62821-001|62821-002Weil McLain 511-330-139 | 511-330-190 | 511-330-193WhiteLBCompany 120-07549White-Rodgers 767A-301 | 767A-303 | 767A-306 | 767A-310 | 767A-311 | 767A-350 | 767A-353 | 767A-354 767A-357 | 767A-361 | 767A-364 | 767A-365 | 767A-366 | F767A-357 | F767A-361 | F767A-365 | F767A-366Williamson 9050York International 025-27766-000 | 025-27774-000 | 025-29043-000 | 025-29050-000 025-32625-000 | 025-32626-000 | 025-33421-000 | 373-05342-700 | 473-12509-001
Ignitors Replaced by URK120VG & URK120VRNote:URK120VRmaybeusedasaflamerodsensor.URK120VFmayNOT.
![Page 179: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/179.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Ga
s h
ea
tin
Gregulators
173
8SECTION
8
Water FeedAlarm/Shut-off System Kit• Easy installation.• No wiring — just plug in.• No maintenance.• Audible alarm and interface with your home security system.• NSF 61/UL/CE/CSA.• Reusable.
WAGS Water and Gas Safety ValveThe WAGS Water and Gas Safety Valve™. The WAGS valve shuts off the water supply (plus has supply for gas-fired water heaters) when it detects a water leak, preventing disastrous flooding and damage to structures and belongings.
WAGSMfr# sIze & connectIon webb#WAGS7200 WaterandGasSafetyShut-OffValveforHotWaterHeaters 243562
Mfr# descrIptIon webb#FLOODMASTER Alarm/Shut-Off Kit 242185
FloodMaster, inc.
Gas Guardian System
Mfr# descrIptIon webb#QMIQGC201RGRS CO/GAS DETECTOR 411881QMIQGKM511GRS CO/GAS GUARDIAN 411882
The Gas Guardian™ Carbon Monoxide & Gas Leak Protection system has taken the original gas leak protection system a step further by adding a carbon monoxide alarm. When the alarm detects carbon monoxide at dangerous levels (as defined by the UL2034 and EN50291 standards) it will cause the gas valve to close, shutting down all gas-appliances and preventing further accumulation of carbon monoxide. This is all done automatically to protect your property, and give you complete peace of mind.
![Page 180: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/180.jpg)
174 victormfg.com
Pump Accessories 9SECTION
Gas Equipment Catalog
Positive Displacement MetersMA™ Series MetersMA-4™/MA-5™MA-4 Meters in Class 10 construction are designed specfically for LPG motor fuel applications (UL Listed):• Capacity: 30 GPM (115 L/min.)• Choice of 11/2” standard and 2” optional companion flanges. MA-5 Meters in Class 10
construction are designed for LPG truck and high speed LPG motor fuel applications (UL Listed)
• Capacity: 60 GPM (225 L/min.)• Choice of 11/2” standard and 2” optional companion flanges.
MA-7™MA-7 Meters in Class 10 construction are designed for LPG truck and bulk loading applications (UL Listed).• Capacity: 100 GPM (380 L/min.).• Class 12 construction for NH3 (Anhydrous Ammonia) service available upon request.• Choice of 2” NPT standard, 11/2” optional companion flanges.
MA-15™MA-15 Meters in Class 10 construction are designed for LPG bulk delivery truck and bulk loading applications (UL Listed).• Capacity: 200 GPM (760 L/min.)• Standard 3” inlet, 2” outlet with choice of NPT, BSPT or steel welding flange
(3” outlet optional).
MA-4-CX-10
MA-7-GY-10
MA-15-GY-10
Model Description Chart – Example shown is meter model
MFR# DeSCRiPtionMAxiMuM noMinAl
Flow RAteStAnDARD
FlAnge SizePRiMARy MAteRiAl webb#
MA-4+
350 PSI21 BAR
2068 kPa
30 GPM (113 L/min.) 11/2” NPT
Aluminum
—MA-5+ 60 GPM (227 L/min.) 11/2” NPT —MA-7+ 100 GPM (380 L/min.) 2” NPT —MA-15+ 200 GPM (757 L/min.) 3” NPT 251204
![Page 181: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/181.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Pump Accessories
175
9SECTION
pu
mp
s/c
om
pr
es
so
rs
9
Power Rewind Reels with Bottom-Mounted Guidemasterto handle single 1” or 11/2” i.D. hoseSeries PbgMbThe Hannay Series PBGMB hose reel is designed specifically for open-deck or compartment mounting, especially when recovery is of an angle other than straight off the reel.Rewind:Choose chain and sprocket drive powered by an electric, hydraulic, or compressed air motor. Gear-driven mechanism with pinion shaft brake can be specified as auxiliary crank rewind on power rewind reels, at extra cost.Brakes & Locks:These reels are supplied with a strap brake. Other brake and locking devices may be specified.Inlet:Standard inlet is 90° ball bearing swivel joint with 11/2” female NPT threads.Outlet:Standard outlet is flanged riser with 11/2” female NPT threads. Standard inlet, outlet riser, and hub assembly are steel.Other sizes and/or threads can be furnished and must be specified.Operating Pressures and Temperatures:These reels operate at pressures to 350 psi (24 bar) and handle product temperatures from -40° F to +350° F (-40° C to + 177° C).Reels to operate at other pressures and temperatures can be furnished at extra cost.
Dimensions and Capacities
Series PBGMB
HoSe CAPACity oF Reel Feet (m) MFR# Reel DiMenSionS inCHeS (MM)
webb#
i.D. (in)I.D. (mm)
1”25.4
11/2”38.1 FOR POwER
REwInD SEE nOTE 2
A b C D eF
eleC.F.
AiRF.
HyDo.D. (in)
O.D. (mm)1.5”38.1
2.16”54.8
——
12545.7
5015.2
PBGMB 24-23-24 21533.4
15.5393.7
10.5266.7
20.5520.7
22.75577.9
29.25743.0
28.25717.6
28.25717.6 —
——
15045.7
7522.9
PBGMB 30-23-24 27.5698.5
22558.8
10.5266.7
20.5520.7
22.75577.9
35.75908.1
34.75882.7
34.75882.7 —
——
20061.0
11033.5
PBGMB 28-25-26 27.5698.5
22558.8
10.5266.7
25.5647.7
24.75628.7
33.75857.3
32.75831.9
32.75831.9 —
Specifications subject to change.
![Page 182: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/182.jpg)
176 victormfg.com
Pump Accessories 9SECTION
Gas Equipment Catalog
Victor/F.w. Webb stocks
siemens generators.
Power Rewind Reels with Bottom-Mounted Guidemaster (continued)
notes:1. Upon request, reels can be supplied with drum lengths other than shown and with disc sizes in
other diameters.2. When ordering power rewind models, prefix model number with:
A = Air Rewind – Supplied with control valve and hose. E = Explosion Proof Electric Rewind (1/2 HP) – Supplied with explosion proof switch, solenoid and
junction box. HD = Hydraulic Rewind – Not supplied with control valve.3. Dimension J is maximum, with fully extended Guidemaster in operating position. Dimension K is
maximum, with fully extended Guidemaster in traveling position opposite rewind motor, as shown in dimensional drawing. Dimension L is maximum, with fully extended Guidemaster in travelling position on same side as rewind motor. (The telescoping feature of the Guidemaster permits each of these dimensions to be reduced up to 4”.) Maximum distance from frame of reel to outside edge of Guidemaster locked in traveling position is 11”.
HoSe CAPACity oF Reel Feet (m) MFR# Reel DiMenSionS inCHeS (MM)
APPRox weigHt lb.
kG.
webb#
i.D. (in)I.D. (mm)
1”25.4
11/2”38.1
FOR POwER REwInD SEE nOTE 2
g H J k l net SHiPo.D. (in)
O.D. (mm)1.5”38.1
2.16”54.8
——
12545.7
5015.2
PBGMB 24-23-24 23.5596.9
12.12307.8
511295.4
39.751009.7
33838.2
16073
18584 —
——
15045.7
7522.9
PBGMB 30-23-24 23.5596.9
12.12307.8
511295.4
431092.2
35.25920.8
17077
20091 —
——
20061.0
11033.5
PBGMB 28-25-26 27.88708.2
15.5393.7
521320.8
421066.8
35.25895.4
17378
20392 —
Specifications subject to change.
![Page 183: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/183.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Pump Accessories
177
9SECTION
pu
mp
s/c
om
pr
es
so
rs
9
Flex HoseFlex ConnectorsMFR# Size webb#FLES50-12 1/2” X 12” 187507FLES75-12 3/4” X 12” 187508FLES100-12 1” X 12” 187500FLES125-12 11/4” X 12” 187501FLES125-18 11/4” X 18” 187502FLES150-12 11/2” X 12” 187503FLES200-14 2” X 14” 187505FLES300-24 3” X 24” 187506
Self-Cleaning StrainersStyle b 112, 600#, threaded, Ductile ironSC000b112AD
Style C 103, 600#, threaded with bolted Cover, Ductile ironSC000C103AD
Style A 105, 300#, Flanged, Ductile ironSC000C103AD
Applications:General purpose Stainless Steel double braided metal flexible gas hose assemblies code rated @ 350 psi available with NPT, ASME flanges, and pipe weld ends. For use typically as a vibration dampener/flexible connector 1/2” – 4” sizes on pump, compressor, and generators. Also available UL536 listed Metal Hose Assemblies suited for Natural Flammable and Combustible Liquid and Gas Service @ 175 psi.All flexible connectors pictured have schedule 80 NPT threaded end with a corrugated stainless hose covered with a double braided stainless steel assembly cover.
LP Gas Flowmeter
MFR# DeSCRiPtion Size webb#LIQLPM102 1 Gal. Register 3/4” 182604— — 2” —
Internationally recognized for our superior flowmeter replacement parts, Liqua-Tech now offers the Model LPM-102 LP Gasliquid flowmeter. Designed for retail sales dispensing units, the LPM-102 offers the widest flow range, (3-18 gpm) available in a meter of this type. In addition, the LPM-102 contains all required accessories including vapor eliminator, strainer and differential valve.
Other sizes can be custom made.
MFR# Size weigHt webb#SCSB112AD-34 3/4” 21/2 lbs. 184112SCSB112AD-1 1” 41/2 lbs. 261609SCSB112AD-114 11/4” 7 lbs. 184114SCSB112AD-112 11/2” 8 lbs. 184115SCSB112AD-2 2” 15 lbs. 193217
MFR# Size weigHt webb#— 2” 20 lbs. —SCB112AD-3 3” 41 lbs. 202666— 4” 100 lbs. —
MFR# Size weigHt webb#— 2” 39 lbs. —SCSSC0300A105AD 3” 65 lbs. S497139SCSSC0400A105AD 4” 130 lbs. S497138
![Page 184: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/184.jpg)
178 victormfg.com
Pump Accessories 9SECTION
Gas Equipment Catalog
Swivel ConnectorsFull-Circle offers a complete line of swivel connectors designed for use with thin to viscous liquids and liquefied gases.Straight-through hose end swivels allow the filler valve to rotate 360°. This enables the driver to make tank connections without fighting the hose. It also prevents hose twisting upon reel-up.For bulk-head use, the 90° swivel allows for the use of a shorter transfer hose and enables the operator to safely sweep the hose to one side for proper, out of the way storage.The design is ideally suited for hose reel use as the sealed high load ball bearing can tolerate misalignment problems that could cause product leakage in other swivel types. The tri-directional movement of the three-piece seal package continually compensates for eccentric movement.The Zero maintenance design is of critical importance, especially for leading/unloading arms that must be constructed high in the air for railroad tankcar transfer operation.Safety First All swivels produced by Full-Circle for LP-gas, ammonia, and flammable liquids are listed by the Underwriters Laboratories and are designed and tested in accordance with the U.L.-567 standard, your assurance that the product has been tested to a standard of safety.No Maintenance Design All Full-Circle swivels unitize a sealed high load ball bearing. No greasing or lubrication is ever required.No Rotating Rubber Seals All full-circle swivels incorporate the superseal™ mechanical seal. This patented design allows the seal ring to “float” between two metallic seals. While in operation, the seal ring rotates at one-half the swivel rotational speed. The tri-directional movement of the seal components allows for continuous adjustment due to vibration, misalignment, and temperature extremes. Upon depressurization, the seal spring maintains a constant force on the seal package, preventing product leakage in zero to low pressure environments.Misalignment Minimized All Full-Circle swivels utilize a radial contact ball bearing with extremely high load ratings. The bearing is sealed for life and requires no periodic lubrication. The ball bearing completely supports the rotating portion of the swivel to ensure smooth and easy movement.Field Replacement Components All full-circle swivels are designed so that replacement parts can be installed simply and easily in the field with no special tools required.
Additional notesTemperature range: -40°F to + 350°FHydrostatic test pressure: 2000 psi for ammonia swivels, 1750 psi for other liquid/ liquefied gasesMaximum working pressure: 400 psi for ammonia swivels, 350 psi for other liquid/liquefied gasesMaximum rotatinal speed: 1000 RPMMaximum load on ball bearing at 33 RPM: 5000 lbs for 11/2” and 2” swivels, 2000 lbs for other SMAC prefix swivels, and 1000 lbs for JO prefix swivelsU.L. Standard:567
SMAC-112LN; 11/2” FNPT 90° Swivel
90° Type
Straight Through Type
Straight-Through Hose End Filler Valve Type
Straight through type — Same thread size for inlet and outlet
90° type — Same thread size for inlet and outlet
Straight Through Hose-End Filler Valve Type — Allows filler valve to rotate 360°
MFR# Size tHReADS A b weigHt webb#SMAC-3490LN 3/4” X 3/4”
Female NPT3” 45/8” 63/4 lbs. 283972SMAC-190LN 1” X 1”
SMAC-114LN 11/4” X 11/4”SMAC-112LN 11/2” X 11/2”
31/4” 43/4” 131/8 lbs. 309126SMAC-200LN 2” X 2”
MFR# Size tHReADS A b weigHt webb#SMAC-34STLN 3/4” X 3/4”
Female NPT51/4” 31/16” 41/2 lbs. —SMAC-1STLN 1” X 1”
SMAC-114STLN 11/4” X 11/4”SMAC-112STLN 11/2” X 11/2”
511/16” 47/8” 113/4 lbs. —SMAC-200STLN 2” X 2”
MFR# Size tHReADS A b weigHt webb#JO-1LN 1” X 1” Female X Male 33/8” 21/2” 11/2 lbs. 246584
![Page 185: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/185.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Pump Accessories
179
9SECTION
pu
mp
s/c
om
pr
es
so
rs
9
Krug CompressorMFR# DeSCRiPtion webb#KRUH50LP Transfer Compressor, LP Engine 182405KRUH50G Transfer Compressor, Gas Engine 182404
qty MFR# DeSCRiPtion webb#Liquid Transfer Hose 30’ HOS3/4 3/4” LP Hose 1856042 HOSHY12-12MP 3/4” Hydraulic Coupling, 2 pieces in kit 185576Compressor Inlet Hose (Bobtail to Compressor) 12’ HOS1/2 1/2” LP Hose 1855812 HOS7661-08MP08TY 1/2” Hydraulic Coupling 193208Compressor Outlet Hose (Compressor to Tank to be Evacuated) 25’ HOS1/2 1/2” LP Hose 1855812 HOS7661-08MP08TY 1/2” Hydraulic Coupling 193208Fittings 1 RGO3175 3/4” Hose Coupling 1626871 F/S34CO3SE 3/4” Hose Coupling, 3M 87351 RGO7550P 3/4” Transfer Angle Valve 1627601 RGO3165CP 1/4” Bleeder Valve* 1868521 RGO7590U-10 3/4” Check Lock Adapter* 1627621 RGO3175B 1/2” Hose Coupling 1868531 RGO3171A 1/2” Vapor Coupling 1626862 JOM100-703 1/2” Ball Valve 151448
basic Hose kit
*Install in 7550P for new style Checklok
![Page 186: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/186.jpg)
180 victormfg.com
Pump Station kits 9SECTION
Gas Equipment Catalog
Pump Station Without Meter
![Page 187: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/187.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Pump Station kits
181
9SECTION
pu
mp
s/c
om
pr
es
so
rs
9
Pump Station Without Meter (continued) Pump Station Schematic Drawing key no MeterDRAwing qty AlPHA CoDe DeSCRiPtion webb#1 1 G/T1000AG 1000 Gal. Above Ground LP Tank 1852241 1 G/T500AG-B 500 Gal. Above Ground LP Tank 2158182 (A,B,C) 1 VCTTANKST Victor Tank Stands, Pump Mount, and Meter Mount 1844383 42’ D/P114BPE 11/4” X 21’ sch40 black pipe price per foot. Use 2 full lengths each leg for 1000 gal., cut 2 to 16’ for 500 gal. 455334 — — Checklok Emergency Liquid Evacuation Valve (Possible Rego 7590U) —5 — — POL Service/Vapor Evacuation Valve (Possible Rego 7556R12.0) —6 — — Double Check Filler Valve (Possible Rego 7579) —7 1 RGOA8017DP Bottom Tank Valve Liquid Service 11/4” X 1” 1624938,9 1 CRKC12SMB Corken Pump C12SMB 11/2” Pnlet 1” Putlet 1 HP Motor With Switch Mounted On Motor And B166 Bypass 18103910 1 NIPCS114X1XH 11/4” X 1” Concentric Swedge Nipple XH 18722011 2 F/S114903SE 11/4” 90 Elbow 3000# Forged Steel Threaded 869312 1 NIP114X10XH 11/4” X 10” XH Black Nipple 18721213 1 SCSB112AD-114 11/4” Ductile Iron Strainer Threaded 18411414 1 F/S34PL 3/4” Plug 3000# Forged Steel Square Head Threaded 883115 1 NIP114X8XH 11/4” X 8” XH Black Nipple 1463616 1 FLES125-12 11/4” X 12” Stainless Steel Double Braided Flex Connector With SCH80 Threaded Ends 18750117 1 F/S114UN3SE 11/4” Union 3000# Forged Steel Threaded 910118 1 F/S112X114BU 11/2” X 11/4” Bushing Forged Steel 887219 1 NIPCS1X34XH 1” X 3/4” Concentric Swedge Nipple XH 18721920 1 F/S34T3SE 3/4” Tee 3000# Forged Steel Threaded 871521 4 NIP34X6XH 3/4” X 6” XH Black Nipple 1460222 1 RGO3127U Rego 1/4” Hydrostatic Relief Valve 450# 16242825 1 F/S14S903SE 1/4” Street 90 Elbow 3000# Forged Steel Threaded 872326 1 CRK1449 Corken Gauge Adapter/Pressure Snubber 1/4” M/F 18109827 1 RGO1224WA Rego 1/4” Needle Valve 18680228 1 F/S14C03SE Coupling 3M FS TH 1/4” —29 1 GAUP300 Ashcroft 21/2” Dial 1/4” Bottom Connection 0-300 psi 3648931 21 D/P34XHBPE 3/4” X 21’ SCH 80 Black Pipe Price Per Foot 4547830 6 F/S34903SE 3/4” 90 Elbow 3000# Forged Steel Threaded 869132 1 RGO7550P Rego 3/4” Angle Valve M/F 16276033 1 RGO7590U-10 Rego Check-lok Adapter, Possible Alternate RGO7572-14C For Older Style Check-lok 16276234 1 F/S34CO3SE 3/4” Coupling 3000# Forged Steel Threaded 873535 2 HGR1GUBOLT 1” Galvanized U-Bolt With Nuts 6903336A 3 HOS3/4 3’ - 3/4” LP Dayco Hose 18560436B 2 HOSHY12-12MP 3/4” Hydraulic Hose Ends For Dayco Hose 18557637 1 RGOA2141A6 Rego 3/4” Breakaway/Pullaway Coupling 16268338 1 F/S34X12BU 3/4” X 1/2” Bushing 3000# Forged Steel 885739A 18 HOS1/2 18’ - 1/2” LP Dayco Hose 18558139B 2 HOS7661-08MP08TY 1/2” Hydraulic Hose Ends For Dayco Hose 19320840 1 RGO7901TB Rego 1/2” X 1/4” Snap Acting Hose Valve 16248841 1 RGO7193D-10 1/4” X MPOL Rego Hose Adapter 186884not shown 1 RGO7193T-10 FPOL X 15/16 F Acme Adapter Rego FPOL-QCC1 Adapter 162472not shown 1 FBS1124 Fairbanks 1124 1000# Scale 181957
![Page 188: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/188.jpg)
182 victormfg.com
Pump Station kits 9SECTION
Gas Equipment Catalog
Pump Station With Meter
![Page 189: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/189.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Pump Station kits
183
9SECTION
pu
mp
s/c
om
pr
es
so
rs
9
Pump Station With Meter (continued) Pump Station Schematic Drawing key with MeterDRAwing qty AlPHA CoDe DeSCRiPtion webb#1 1 G/T1000AG Tank LP Above Ground 1000 Gal. 1852241 1 G/T500AG-B Tank LP Above Ground Bot./Drn. 500 2158182 2 SAE38RNUT Nut Short Ref. 3/8” * NS45 E6NUT 345713 1 SAE38X14MUN Union 3/8 X 1/4 FLR X M * U1-6B 197804 1 SAE38X14M90 ELL 90 3/8 X 1/4 FLR X M * E1-6B 198345 1 PIG1005 POL X 3/8 Male Flare 186522 6 2 SAE58X34MUN Union 5/8 X 3/4 FLR X M * U1-10E 19791 7 2 SAE58RNUT Nut Short Ref 5/8 * NS410 E10NU 348148 1 RGO7550P Valve Angle Trans. * 3/4 1627609 1 RGO7590U-10 Adapter Check Lock * 3/4 16276210 2 RGO3127U Valve Relief Hydro 450 1/4” 16242811 1 RGOA8017DP Valve Multi Purpose 11/4 MN 16249312 1 NIPCS114X1XH Nipple Conc. Swedge 11/4 X 1 X H 18722013 1 F/S1903SE Elbow 90 3M FS TH 1” 869214 1 NIP1X 3XH Nipple Black X H 1 X 3 STL 1461215 1 F/S114903SE Elbow 90 3M FS TH 11/4” 869316 1 NIP114XHPAK Nipple BLK X H PAK 1 EA 11/4 X CLO 11165517 1 SCSB112AD-114 STRNR 11/4 DI 600 THD 20” MESH 18411418 1 F/S1PL Plug 3M FS SQ HD 1” 883219 1 FLES125-12 Hose 11/4 X 12 SS SGL BRD S80MN 18750120 1 F/S114UN3SE Union 3M FS TH AAR 11/4” 910121 1 NIPCS112X114XH Nipple Conc. Swedge 11/2 X 11/4 X H 18722122 1 CRKC12SMB Kit Pump 1 HP MTR MNT SW 3/4 BY 18103923 1 NIPCS1X34XH Nipple Conc. Swedge 1 X 3/4 X H 18721924 1 F/S34T3SE Tee 3M FS TH 3/4” 871525 1 NIP34XHPAK Nipple BLK X H PAK 1 EA 3/4 X CLO 11166926 1 F/S34UN3SE Union 3M FS TH AAR 3/4” 909927 1 NIP34X24XH Nipple Black 34 X 24 X H WLD 31889728 3 F/S34903SE Elbow 90 3M FS TH 3/4” 869129 1 F/S34T3SE Tee 3M FS TH 3/4” 871530 1 F/S34X12BU Bushing 3M FS HEX 3/4 X 1/2 885731 1 RGO3129U Valve Relief Hydro 450 1/2” 16243232 1 LIQLPM102 Meter Flow With 1 Gallon Register 18260433 1 RGO3272G Valve Excess Flow 3/4” 16258434 3 HOS3/4 Hose LP 3/4 7132-75354 18560435 2 HOSHY12-12MP Coupling Hydraulic 3/4 18557636 1 RGOA214A6 Valve Pull Away 3/4” 16268337 1 F/S34X12BU Bushing 3M FS Hex 3/4 X 1/2 885738 18 HOS1/2 Hose LP 1/2 7132-50354 18558139 2 HOS7661-08MP08TY Coupling Hydraulic 1/2 19320840 1 RGO7901TB Valve Quick Act 1/4 FN X 1/2 FN 16248841 1 RGO7193D-10 Connector Fill With Soft Nose 18688442 1 RGO7193T-10 Adapter Fill FPOL X 15/16 AC 16247243 1 RGO07193L-10A Connector Fill 162471
![Page 190: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/190.jpg)
184 victormfg.com
Pump Station kits 9SECTION
Gas Equipment Catalog
Pump Station With Meter (continued) Pump Station Schematic Drawing key with MeterDRAwing qty AlPHA CoDe DeSCRiPtion webb#44 1 RGO5760A Adapter FP X 1/4 FN 16245745 1 SHR901H FPOL X 13/4 Acme S 18411946 1 CRK1449 Adapter Pressure Gauge 18109847 1 F/S14S903SE Elbow 90 3M FS TH ST 1/4” 872348 1 RGO1224WA Valve Needle Brass 1/4 18680249 1 F/S14CO3SE Coupling 3M FS TH 1/4” 873250 1 ASH00516 Gauge 63 3005PHL 02L 300 11092051 42 D/P2BPE Pipe S40 BLK PE 2 X FT 4550452 8 HGR12GWASHER Washer Flat PLT 1/2 130 PG 6905153 4 HGR12GNUT Nut HEX HD PLT 1/2” 110 HPG 6904654 4 HGR12X2GBOLT Bolt HEX HD GAL 1/2 X 2 41 PG 3445855 1 VCTTANKST Stands Tank With Pump 18443856 1 FBS1124 Scale Portable Beam 18195757 1 MIL48-89-1565 Bit Twist Drill 1/4 7466558 1 MIL48-89-1645 Bit Twist Drill 1/2 24764259 — — 15 Feet 1/4 K Soft Copper 362953 60 — — 10 Feet 1/2 K Soft Copper 360279
Victor/F.w. Webbstocks york furnaces.
![Page 191: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/191.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Pumps/Compressors
185
9SECTION
pu
mp
s/c
om
pr
es
so
rs
9
Coro-Flo® Turbine Pumps
C-Model With Close Coupled Motor
SPeCiFiCAtionS MoDel 10 12 13 14Inlet 11/4” NPT 11/2” NPT 11/2” NPT 11/2” NPTOutlet 1” NPT 1” NPT 1” NPT 1” NPTRPM-60 Hz 3450 3450 3450 3450Max. Differential Press.50 Hz PSI (Bar) 60 (4.1) 75 (5.2) 75 (5.2) 75 (5.2) 60 Hz PSI (Bar) 70 (4.8) 100 (6.9) 125 (8.6) 125 (8.6)Mounting OptionsClose Coupled Yes Yes Yes Yes Direct Driven (101) Yes Yes Yes Yes V-Belt (103) Yes Yes Yes YesDirect Mounted Frame(DS/DL) Yes Yes Yes YesDouble Seal Option(Except C-Model) Yes Yes Yes YesFlange Option11/2” X 1” — 300# Yes Yes Yes Yes(Except C-Model)Impeller Material Opt. Bronze (Standard), Ductile Iron, Stainless SteelO-Ring Material Opt.Teflon(r), Viton(r), Buna-N (Standard), Neoprene(r), Teflon(r), Ethylene-Propylene Viton(r), Ethylene-Propylene Seal Seat Material Options Ceramic Ni-Cast Iron, Cast Iron (Standard), Ni-Resist, Stainless Steel, SS304, Tungsten Carbide Tungsten Carbide, CeramicTemperature -25/225°F -25/225°F -25/225°F -25/225°F(min/max) -32/107°C -32/107°C -32/107°C -32/107°CMaximum Driver 5 HP 10 HP 10 HP 20 HP 3.7 KW 7.5 KW 7.5 KW 15 KW
MFR# DeSCRiPtion webb#Dispensing Station PumpsCRKC10S 3/4 HP, 115/230V Remote 181031CRKC10SB 3/4 HP, Remote Switch, Bypass 181032CRKC10SM 3/4 HP, 115/230V Switch 181033CRKC10SMB 3/4 HP, SW Mount & Bypass 181034CRKC12 1 HP Motor 181035CRKC12S 1 HP 115/208/230 Remote 181036CRKC12SB 1 HP Motor, Remote Switch 181037CRKC12SM 1 HP 115/208/230 Switch 181038CRKC12SMB 1 HP Kit, SW Mount 3/4 Bypass 181039CRKC13 2 HP Motor 212890CRKC14 3 HP Motor, SW Mount 204939
Stationary ApplicationsDesigned specifically for LPGThe Corken Coro-Flo® pump was designed for LPG, NH3 and other light liquids. For low-capacity, medium-head pumping, the Coro-Flo pump is the pump of choice. Extremely quiet and free of vibration and pulsation, the Coro-Flo pump provides trouble-free service and long life for volatile liquids such as LPG. The exclusive turbine construction provides smooth continuous flow through the pump case, resulting in higher efficiency and greater capacity and pressure for the same size motor. The one moving part, the impeller, floats on the shaft without contacting adjacent surfaces, thus extending pump life.Simple to ServiceThe Coro-Flo® pump has been designed for simplicity of inspection and service. The cover can be removed and the impeller and seal serviced without disturbing the piping. The balanced mechanical seal is furnished with its own sleeve, providing extremely reliable service.The Coro-Flo pump is listed by Underwriters’ Laboratories, Inc. for use in LP-Gas and anhydrous ammonia service.
![Page 192: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/192.jpg)
186 victormfg.com
Pumps/Compressors 9SECTION
Gas Equipment Catalog
MotoR (A) ReCoMMenDeD wiRe Size, Awg
MoDel HPMotoR PHASe voltS
APPRoxiMAte Full loAD AMPeReS
lengtH oF Run in Feet
0-100 to 200 to 300C9C10
3/4—
1—
115230
9.05.0
1212
812
612
C12 1 1 115230
16.08.0
812
612
410
C13 2 1 115230
20.010.0
812
410
28
C14 3 3 230460
8.04.0
1212
1210
128
Coro-Flo® Turbine Pumps Stationary Applications (continued)
FOR MODELS C9, C10, C12 AND C13 FOR MODELS C14 ONLY
115V2277-X1 OR 2277-X2 SWITCH
LINE
LINE
L2T2
L1
T1
T2
T3
T4
T1 L1
T2 L2
T1
T3
T1
T2
T4
LINE
LINE
208-230V2277-X1 OR 2277-X2 SWITCH
208-230V 460V
LINE
LINE
4 7 1
8 2
9
7
8
93
5
6
4
5
6LINE
LINE
LINE
1
2
3LINE
FOR MODELS C9, C10, C12 AND C13 FOR MODELS C14 ONLY
115V2277-X1 OR 2277-X2 SWITCH
LINE
LINE
L2T2
L1
T1
T2
T3
T4
T1 L1
T2 L2
T1
T3
T1
T2
T4
LINE
LINE
208-230V2277-X1 OR 2277-X2 SWITCH
208-230V 460V
LINE
LINE
4 7 1
8 2
9
7
8
93
5
6
4
5
6LINE
LINE
LINE
1
2
3LINE
Wire Sizing Chart
Pump must rotate in the direction shown on pump case. If not, switch any two of the three incoming 3 phase lines.
Victor/F.w. Webb stockselectrical test equipment.
See our tools section in this catalog.
![Page 193: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/193.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Pumps/Compressors
187
9SECTION
pu
mp
s/c
om
pr
es
so
rs
9
Coro-Flo® Pumps
F-Model 101 Direct Drive
FF150CD6A
DS/DL-Model Direct Mounted
MFR# DeSCRiPtion webb#Dispensing Station/Aerosol/Refrigerant PumpsCRKF10CD Pump f/10 181043CRKF12CD Bare Coro-Flo 181044CRKF14CD Bare Coro-Flo 181045CRKDL14 Direct Mount, Large Frame 181211CRKDS12CDC Direct Mount, Small Frame 181216FF150CD6A Autogas Pump 369968
SPeCiFiCAtionS
MoDelS
FF150 DlF150Inlet 11/2” ANSI 300# R.F. Flange 11/2” ANSI 300# R.F. FlangeOutlet 1” ANSI 300# R.F. Flange 1” ANSI 300# R.F. FlangeRPM—50 Hz 2,880 2,880RPM—60 Hz 3,450 3,450
Maximum Working Pressure 28.5 bar(400 psi)
28.5 bar(400 psi)
Maximum Differential Pressure50 Hz60 Hz
200 psi (13.8 bar)250 psi (17.2 bar)
200 psi (13.8 bar)250 psi (17.2 bar)
Mounting Options — —Direct Driven (101) Yes NoV-Belt (103) Yes NoDirect Mounted Frame No YesImpeller Material Options Bronze (Standard), Ductile Iron, Stainless SteelO-Ring Material Options Buna-N (Standard), Neoprene®1, PTFE®1, Viton®1, Ethylene-PropyleneSeal Seat Material Options Cast Iron (Standard), Ni-Resist, Stainless Steel, Tungsten Carbide, CeramicTemperature (Min/Max)
(-25) 225ºF(-32) 107ºC
(-25) 225ºF(-32) 107ºC
Maximum Driver 20 hp15kW
20 hp15kW
Type of Electric Motor Rigid-Base C-Face
Autogas Pumps — Operating Specifications
1 Neoprene®, Viton® and PTFE® are registered trademarks of the DuPont Company.
Autogas PumpsCorken Autogas Pump achieves new levels of performance with higher flows at high differential pressures, non-pulsating and quiet transfer, longer pump life and a design that is easy to repair. The pump is also versatile enough to be used in like applications such as cylinder filling, vaporizer feeding, or bulk transfer.
F-Model The F-Model pump is the base plate mounted version. Coro-Flo® pumps are design to operate at shaft speeds between 2880—3600 rpm. The F-Model provides the flexibility of motor selection.
DS/Dl Model The DS/DL Model pumps are designed to eliminate the need for a baseplate, coupling guard, and coupling alignment which makes the DS/DL series pumps compact and easy to install. The special bracket supports both the pump and the motor so they can be directly coupled.
![Page 194: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/194.jpg)
188 victormfg.com
Pumps/Compressors 9SECTION
Gas Equipment Catalog
Curves based on L/min
CapacityPower Required
00
2.5
5.0
7.5
10.0
12.5
15.0
17.5
0
2.5
5.0
7.5
10.0
12.5
15.0
17.5
50 100 150 200 250
gpmCapacity
L/min.
0 10 20 30 40 50 60
0
50
100
150
200
250
bar
Diff
eren
tial P
ress
ure
psi kw hp
0
3.0
5.0
7.5
10.0
15.0
20.0
Coro-Flo® Pumps (continued)
Autogas Capacity Chart
Victor/F.w. Webb stocks the laarsmascot gas boiler. it provides both heat
and domestic hot water!
![Page 195: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/195.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Pumps/Compressors
189
9SECTION
pu
mp
s/c
om
pr
es
so
rs
9
Coro-Vane® Pumps
bulk Filling, Carousel Filling & Cylinder Filling
MFR# DeSCRiPtion webb#Stationary Plant PumpsCRK521EF* Stationary Coro-Vane 181022CRK521EG103* Coro-Vane Pump With Mount 181023CRK1021EF* Bare Coro-Vane Pump 181013CRK1021EF103* Coro-Vane Pump With Mount 284T 181042Z3500 Coro-Vane Z-Pump 401115Z3500-103 Pump With Mount 401116
521
521 1021 1521
1021 1521
10 20 30 40 50 60 80
420
640
860950
420
640
860950
100 150 200
GPM
M3/hr
RPM
250 300
100 PSID(6.90 Bar)
40 PSID(2.76 Bar)
Corken Coro-Vane® pumps are positive displacement pumps. They produce a maximum differential pressure of 125 psig (8.6 bar g). Corken manufactures four sizes of Coro-Vane pumps, ranging from 1gpm to 350 gpm (0.2–79.5 m3/hr). Corken offers these pumps with v-belt or direct-drive mounting options.
*Soon to be obsolete.
z-Series z3500 Stationary and truck PumpThe new three-inch Z3500 LPG pump is designed for stationary and foot mounted truck applications. The Z3500 stationary pump has the same locked rotor design used in the Corken Z-Series truck pumps to ensure long pump life and excellent performance. With higher flow rates than other three-inch pumps, the Z3500 retrofits Corken’s and other competitive pumps with little or no change in piping.
1021EF103
521 Cutaway
![Page 196: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/196.jpg)
190 victormfg.com
Pumps/Compressors 9SECTION
Gas Equipment Catalog
MFR# DeSCRiPtion webb#Coro-Vane Pump TrucksCRKZ3200 Pump Truck 181234CRKZ4200 4” Transport 204940
Coro-Vane® Truck Pumps
Z3200
Z4200
SpecificationsSPeCiFiCAtionS MoDelS Z3200 Z4200Suction Flange 3” 4” 300# ANSI 300# ANSIDischarge Flange 2” 2” NPT EI Dual NPTMaximum RPM 800Minimum -25°FTemperature (-32°C)Maximum 225°FTemperature (107°C)Maximum 400 PSIGWorking Pressure (28.6 Bar)Maximum 125 PSIDDifferential Pressure (8.6 Bar)Discharge Flange Open Yes NoInternal Relief Valve Yes YesSteel Slip-OnFlange Option Yes Yes
Z3200 Performance Chart
PuMP SPeeDDiFFeRentiAl
PReSSuReAPPRoxiMAte
DeliveRy on PRoPAne bRAke HP RequiReDPuMP toRque
RequiReD
RPM PSi bAR gPM lPM bHP kw Ft. lbS. kg/M800800
50100
—6.9
121110
460420
6.610.6
4.97.9
43.469.3
6.09.6
650650
50100
3.46.9
9888
371333
5.28.2
3.96.1
42.066.3
5.89.2
500500
50100
3.46.9
7363
276238
3.85.8
2.84.3
39.960.9
5.58.4
The Z-Series Coro-Vane® truck pumps are specifically designed to perform in such severe operating conditions as high differential pressure, pump overspeeding, poor suction conditions and heavy thrust loads associated with a power take-off (PTO) drive system.
![Page 197: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/197.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Pumps/Compressors
191
9SECTION
pu
mp
s/c
om
pr
es
so
rs
9
SPeCiFiCAtionS MoDel 91 291 491 691 891Bore of CylinderInches (MM) 3.0 (76.2) 3.0 (76.2) 4.0 (101.6) 4.5 (114.3) 4.5 (113)Stroke Inches (MM) 2.5 (63.5) 2.5 (63.5) 3.0 (76.2) 4.0 (101.6) 4.0 (101.6) Piston Displacement CFM (m3/HR)Minimum @ 400 RPM 4.0 (6.8) 8.0 (13.6) 17.2 (29.2) 29.2 (49.6) 56.6 (96.2) 76.8 (130.5)Maximum @ 825 RPM 8.3 (14.1) 16.5 (28.0) 35.5 (60.3) 60.2 (102.3) 113.2 (192.0)Maximum @ 1200 RPM — — — — —Max. Working Pressure 350 (24.1) 350 (24.1) 350 (24.1) 350 (24.1) 465 (32.1)Max. Brake Horesepower (KW) 7.5 (5.6) 15 (11) 15 (11) 35 (26.1) 45 (34)Maximum Rod Load LP (KG) 3600 (1632.9) 3600 (1632.9) 4000 (1814.4) 5500 (3175.2) 7000 (3175.2)Max. Outlet Temp. °F (°C) — — — 350 (177) —Bare Unit Weight LB (KG) 115 (52.2) 160 (72.6) 260 (117.9) 625 (283.5) 855 (387.8)Maximum Flow-Propane 50 (11.4) 101 (22.9) 215 (48.8) 36 (82.0) 694 (157.6)GPM (m3/HR) ANSI/DIN Flange Option F91 F291 F491 F691 —
CompressorThe “107” bulk plant gas compressor unit is complete with pressure gauges, steel baseplate, mechanical liquid trap, four-way valve, strainer, interconnecting piping, adjustable driver-slide-base, v-belt drive and beltguard ready to receive an electric motor. This standard unit is typically used for liquid transfer and vapor recovery in applications including rail car and truck loading and unloading. Many options such as ASME liquid traps with Class1, Group D switches and total engineered packages can be provided.
MFR# DeSCRiPtion webb#Gas Transfer CompressorsCRK91-107A (see table below) 181024CRK291-107 (see table below) —CRK491-107 (see table below) —CRK691-107 (see table below) —
Model 107
Victor/F.w. Webb stocks rinnai continuum water heaters.
we can also help you size your job!
![Page 198: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/198.jpg)
192 victormfg.com
Pumps/Compressors 9SECTION
Gas Equipment Catalog
Appendix C—Compressor Selection
1 The capacities shown are based on 70°F, but will vary depending upon piping, fittings used, product being transferred and temperature. The factory can supply a detailed computer analysis if required.
2 Driver sheaves: 91 (2 belts); 290, 291, 490, 491 (3 belts); 690, 691 (4 belts).3 The piping sizes shown are considered minimum. If the length exceeds 100 ft., use the next larger size.NOTE: Please consult factory for compressors with higher flows.
Driver Horsepower Liquid Liquid Transfer Transfer & Without Residual Residual Driver Sheave Size Vapor Vapor Capacity Displacement Compressor Pitch Diameter (inches)2 Recovery Recovery Piping Size3
Service gpm1 cfm Model RPM 1,750 RPM 1,450 RPM 100°F 80°F 100°F 80°F Vapor Liquid 23 4 91 400 A 3.0 A 3.6 5 3 3 3 3/4 1-1/4 Small 29 5 91 505 A 3.8 B 4.6 5 5 5 5 3/4 1-1/4 bulk 34 6 91 590 B 4.6 B 5.6 5 5 5 5 1 1-1/4 plants 40 7 91 695 B 5.4 B 6.6 5 5 5 5 1 1-1/2 39 7 290, 291 345 A 3.0 A 3.6 3 3 3 3 1 1-1/2 45 8 91 795 B 6.2 B 7.4 7-1/2 7-1/2 7-1/2 7-1/2 1 1-1/2 44 8 290, 291 390 A 3.4 B 4.0 5 3 3 3 1 1-1/2 50 9 290, 291 435 A 3.8 B 4.6 5 5 3 3 1 1-1/2 56 10 290, 291 490 B 4.4 B 5.2 5 5 5 5 1 2 Unloading 61 11 290, 291 535 B 4.8 B 5.8 5 5 5 5 1 2 single tank 66 12 290, 291 580 B 5.2 B 6.2 7-1/2 5 5 5 1 2 car or 71 13 290, 291 625 B 5.6 B 6.6 7-1/2 5 7-1/2 5 1-1/4 2 transport 79 14 290, 291 695 B 6.2 B 7.4 7-1/2 7-1/2 7-1/2 7-1/2 1-1/4 2 84 15 290, 291 735 B 6.6 B 8.0 10 7-1/2 10 7-1/2 1-1/4 2-1/2 84 15 490, 491 345 A 3.0 A 3.6 7-1/2 7-1/2 5 5 1-1/4 2-1/2 89 16 290, 291 780 B 7.0 B 8.6 10 10 10 10 1-1/4 2-1/2 89 16 490, 491 370 A 3.2 A 3.8 7-1/2 7-1/2 7-1/2 5 1-1/4 2-1/2 95 17 490, 491 390 A 3.4 B 4.0 7-1/2 7-1/2 7-1/2 7-1/2 1-1/4 3 101 18 490, 491 415 A 3.6 B 4.4 10 7-1/2 7-1/2 7-1/2 1-1/4 3 106 19 490, 491 435 A 3.8 B 4.6 10 7-1/2 7-1/2 7-1/2 1-1/4 3 108 20 490, 491 445 B 4.0 B 4.8 10 7-1/2 7-1/2 7-1/2 1-1/4 3 114 21 490, 491 470 B 4.2 B 5.0 10 7-1/2 7-1/2 7-1/2 1-1/4 3 Unloading 119 22 490, 491 490 B 4.4 B 5.2 10 10 7-1/2 7-1/2 1-1/4 3 two or 125 23 490, 491 515 B 4.6 B 5.6 10 10 10 7-1/2 1-1/4 3 more tank 130 24 490, 491 535 B 4.8 B 5.8 15 10 10 10 1-1/4 3 cars at 136 25 490, 491 560 B 5.0 B 6.0 15 10 10 10 1-1/4 3 one time 141 26 490, 491 580 B 5.2 B 6.2 15 10 10 10 1-1/4 3 or large 147 27 490, 491 605 B 5.4 B 6.4 15 10 15 10 1-1/4 3 transport 152 28 490, 491 625 B 5.6 B 6.6 15 15 15 15 1-1/2 3 with excess 158 29 490, 491 650 B 5.8 B 7.0 15 15 15 15 1-1/2 3 flow valves 163 30 490, 491 670 B 6.0 15 15 15 15 1-1/2 3 of adequate 163 30 690, 691 400 B 4.4 B 5.2 15 15 10 10 1-1/2 3 capacity 168 31 490, 491 695 B 6.2 B 7.4 15 15 15 15 1-1/2 3 171 31 690, 691 420 B 4.6 B 5.6 15 15 10 10 1-1/2 3 179 32 490, 491 740 B 6.6 B 8.0 15 15 15 15 1-1/2 3 178 32 690, 691 440 B 4.8 B 5.8 15 15 10 10 1-1/2 3 186 34 690, 691 455 B 5.0 B 6.0 15 15 15 10 1-1/2 3 193 35 690, 691 475 B 5.2 B 6.2 15 15 15 10 1-1/2 3 200 36 690, 691 495 B 5.4 B 6.4 15 15 15 15 1-1/2 3 208 38 690, 691 510 B 5.6 B 6.8 20 15 15 15 1-1/2 4 215 39 690, 691 530 B 5.8 B 7.0 20 15 15 15 1-1/2 4 223 41 690, 691 550 B 6.0 A 7.0 20 15 15 15 1-1/2 4 230 42 690, 691 565 B 6.2 B 7.4 20 15 15 15 2 4 Unloading 237 43 690, 691 585 B 6.4 A 7.4 20 15 15 15 2 4 large 245 45 690, 691 605 B 6.6 B 8.0 20 15 15 15 2 4 tank cars, 252 46 690, 691 620 B 6.8 20 20 15 15 2 4 multiple 260 47 690, 691 640 B 7.0 A 8.2 20 20 20 15 2 4 vessels, 275 48 690, 691 675 B 7.4 B 8.6 25 20 20 20 2 4 barges or 297 54 690, 691 730 B 8.0 B 9.4 25 20 20 20 2 4 terminals 319 58 690, 691 785 B 8.6 25 20 25 20 2 4 334 60 690, 691 820 TB 9.0 A 10.6 30 25 25 20 2 4 452 82 D891 580 5V 7.1 5V 8.5 30 30 30 30 3 6 623 113 D891 800 5V 9.75 5V 11.8 40 40 30 3 6
Propane Compressor Selection Table
36
Compressor SelectionPropane Compressor Selection table
![Page 199: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/199.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
bypass valves
193
9SECTION
pu
mp
s/c
om
pr
es
so
rs
9
SPeCiFiCAtionS
MoDelS
b166b t166 b177 zv200Inlet 3/4”, 1” 11/4”, 11/2” 2”, 21/2” 2”Outlet 3/4”, 1” 11/4”, 11/2” 2”, 21/2” 2”Slip-On Flange Option No No 2”, 21/2” NoDifferential Pressure Range 22 – 225 psi 22 – 225 psi 10 – 125 psi 91 – 125 psiO-Ring Material Options Buna-N (Standard), Neoprene®1, PTFE®1, Viton®1, Ethylene-Propylene*
MFR# DeSCRiPtion webb#B166B75B 3/4” Coro-Flo®/Autogas 181026B166B1B 1” Coro-Flo®/Autogas 181025B177125B 11/4” Coro-Vane® 181027B177150 11/2” Coro-Vane® 181028B1772B 2” Coro-Vane® 181029T166–1.25 11/4” Truck Pump 181049
Bypass Valves—Specifications for B166, T166, B177 and ZV200
* Ethylene-Proplyene not available for B177, 1 PTFE®, Vitron® and Neoprene® are registered trademarks of the DuPont Company.
Bypass Valveszv200 bypass valveThe two-inch ZV200 is a low pressure build-up bypass valve designed for applications requiring protection for positive displacement pumps. Specifically designed for protecting pumps with capacities up to 250 gpm (946 L/min). The continuous internal bleed will assist in the operation of systems with “air” or “electric” operated internal valves. Typical applications include bobtail, transport and stationary loading and unloading of LPG, NH3 and other light liquids.
ApplicationsUsed for both truck and stationary applications for loading and unloading.
Features and Benefits• Dimensionally interchangeable with commonly used two-inch bypass valves; no need to change piping configuration.• Ductile iron construction offers maximum strength for higher pressures.• Flow rates up to 250 gpm (946 L/min) at 120 psi (8.3 bar) differential.• Continuous bleed helps equalize pressure to assist remote operated internal valves.• Multiple spring options enable you to select the pressure required for your truck or stationary application.
ZV200
![Page 200: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/200.jpg)
194 victormfg.com
bypass valves 9SECTION
Gas Equipment Catalog
b166 (3/4” and 1”) Automatic Dual Purpose, bypass valvesThe B166B is a combination bypass and priming valve specifically designed for small cylinder filling type pumps, especially of the regenerative turbine type, such as the Coro-Flo pump series. The patented vapor elimination system keeps liquefied gas pumps primed to increase system reliability and decrease pump and seal wear. The B166B is a smooth operating bypass with moderate pressure buildup.
ApplicationsUsed with all cylinder filling pumps. (Coro-Flo Models and low flow side channel pumps).
t166 (11/4” and 11/2”) Pump Flow Control valveThe T166 valve provides smooth-acting flow control. Specifically designed for bypass protection for pumps in the 30–100 GPM (6.8–22.7 m3/hr) range, such as those used on delivery trucks. In contrast to the B177, the T166 valve opens gradually as pressure builds up to modulate the flow, bypassing the excess capacity smoothly and silently back to the supply tank. A continuous internal bleed in this valve assists in eliminating vapors.
ApplicationsUsed with large capacity pumps filling various sizes of tanks and bottles such as those used with delivery trucks or multi-spot cylinder-filling plants.
b177 (2” and 21/2”) Differential bypass valveThe B177 is a low-pressure buildup valve specifically designed for applications requiring protection for positive displacement pumps in the 50–350 GPM (11.4–79.5 m3/hr) for smooth-acting flow control. To properly function, this valve requires a pressure sensing line for the storage tank. This valve should be applied where horsepower is limited and accuracy set points and flow points are necessary.
ApplicationsUsed in liquefied-gas bulk plant installations for the loading and unloading pumps.
Bypass Valves (continued)
B166
B177
![Page 201: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/201.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
electric Motors
195
9SECTION
pu
mp
s/c
om
pr
es
so
rs
9
Explosion Proof TEFC (IP54)ul and CSA ApprovedThe WEG line of World Energy Guardian TM Motors are specifically designed to meet or exceed ALL APACT requirements for energy efficiency.
Standard Features:• 3 phase, 60 Hz, 208-230/460,460 or 575 V.• 143T up to 586/7 cast iron frame.• Squirrel cage rotor/Aluminum die cast.• Enclosure TEFS (IP54).• All motors supplied with ball bearings except roller bearings in drive end for frames
404T and up, in IV, VI, and VII pole.• Class “F” insulation.• Temperature rise: Class “B” (80°C).• Service factor: 1.15 (see electrical data for exceptions).• Dimensions according to NEMA standard.• NEMA ratings design “B” (except 900RPM Design “A”).• Continuous duty (S1).• 104°F (40°C) ambient temperature.
neMAFRAMeS
Mounting
A b C D g J k o P t2e 2F H bA14 3T
5.5004.000
0.344 2.250 6.4575.157 12.760
3.500 0.429 1.496 1.654 7.000 7.000 —14 5T 5.000 6.142 13.75218 2T
7.7504.500
0.4062.750 8.661
5.945 14.8624.500 0.787 1.890 1.969 9.421 8.909
1.77218 4T 5.500 6.969 15.86221 3T
8.5005.500
3.500 9.7647.402 17.952
5.250 0.827 2.008 2.185 11.156 10.70921 5T 7.000 8.898 19.45025 4T
10.0008.252
0.531 4.250 12.12610.000 23.175
6.250 0.817 2.520 2.559 12.352 12.224 2.08725 6T 10.000 11.732 24.929
MFR# DeSCRiPtion webb#MTR00218XP3E245T HP 2 XProof 3 Phase 1800 RPM Motor 318199 MTR00718XP3E213T Motor 71/2 HP 1800 RPM 3PH 208V 206666MTR0108XP3E215T 10 HP 1800 RPM 3PH XProof Motor 183302MTR01518XP3E254T #15 HP 3 Phase 1800 RPM X PR 254T FR —MTR02018XP3E256T #20 HP 3 Phase 1800 RPM EXP. Proof —MTR02518XP3E284T #25 HP 3 Phase 208V RPM 284T M —
![Page 202: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/202.jpg)
196 victormfg.com
electric Motors 9SECTION
Gas Equipment Catalog
Explosion Proof TEFC (IP54) (continued)
neMAFRAMeS
keywAykey
lengtH
SHAFt extenSion
Ab AA d1
beARingS
wiDtH DePtH n-w u De oD.e14 3T
0.187 0.093 1.375 2.250 0.875 6.811NPT 3/4”
A4
6205-ZZ 6204-ZZ14 5T18 2T
0.250 0.125 1.750 2.750 1.125 8.240 6307-ZZ 6206-ZZ18 4T21 3T
0.313 0.156 2.375 3.375 1.375 9.252 NPT 1” 6308-ZZ 6207-ZZ21 5T25 4T
0.375 0.187 2.875 4.000 1.625 11.063 NPT 11/2” 6309-C3 6209-ZOC325 6T
Victor/F.w. Webb stocks rinnai space heaters. we can also help you correctly
size them with a building heat loss!
![Page 203: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/203.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Repair Parts
197
9SECTION
pu
mp
s/c
om
pr
es
so
rs
9
Parts Details for Models C9 to C14
O-Ring Code
A Buna-N
B Neoprene ® 1
E Teflon ® 1
ReF# MFR# DeSCRiPtion qty webb#
1 7001-031- NC100A Hex Head Cap Screw 8 —
2
1001-091001-01001-21001-31001-41001-5
Cover—Model 9Cover—Model 10Cover—Model 12Cover—Model 13Cover—Model 14Cover—Model 15
111111
——————
310142
1014-12
Case Clearance Shim (.002” Red)
Case Clearance Shim (.003” Green)
As Req.As
Req.
181071
—
4 2-246 2, 3
2-247E2Case O-Ring (Non-Teflon®1)
Case O-Ring Teflon®111
——
5
1003-096
1003-06
1003-26
1003-36
1003-46
1003-56
Impeller, Brass—Model 9Impeller, Brass—Model 10Impeller, Brass—Model 12Impeller, Brass—Model 13Impeller, Brass—Model 14Impeller, Brass—Model 15
111111
—181060181062181063181064
—
6
113-CX_3
113-CXA113-CXB113-CXD113-CXE
Seal AssemblySeal AssemblySeal AssemblySeal AssemblySeal Assembly
11111
—181075181076181077181057
7
1004-1X
1004-11X
1004-2X
1004-21X
Seal Housing, Steel (Non-Teflon®1 O-Rings)
Seal Housing, SS (Non-Teflon®1 O-Rings)
Seal Housing, Steel (Non-Teflon®1 O-Rings)
Seal Housing, SS(Non-Teflon®1 O-Rings)
1
1
1
1
310362
—
—
—
81013
1013-1
Housing Adjustment Shim (0.010”)
Housing Adjustment Shim (0.020”)
As Req.As
Req.
181069
—
ReF# MFR# DeSCRiPtion qty webb#9 2-224_3 Housing O-Ring 1 —
10 3442 Pipe Plug, 1/4” NPT 1 —11 3444 Pipe Plug, 3/4” NPT 1 —
12
1002-091002-01002-21002-31002-41002-5
Case—Model 9Case—Model 10Case—Model 12Case—Model 13Case—Model 14Case—Model 15
111111
——————
13 1914-1 Nameplate 1 —
14 7012- 006SF019E Phillips Head Screw 6 – 32X1/4” 2 —
15 7002- 037NC087A Socket Head Cap Screw 8 —
16 1015 Adapter Ring 1 —
17 24972497-1
Woodruff Key, SteelWoodruff Key, SS
11
——
18
2555255625575
28955
28965
42614
Motor 3/4 HP Models 9, 10Motor 1 HP Model 12
Motor 3 HP Models 14, 15Motor 3/4 HP,
Obsolete Models 9E, 10Motor 11/2 HP,
Obselete Model 12EMotor 2 HP Model 13
1111 1
1
181167181168
——
—
—
1 Registered trademarks of the DuPont Company.2 Included with seal assembly/repair kit 113-CX_.3 _Denotes O-Ring Code.4 Prior to S.N. PR166727 motor part number was 3760.5 Starting with S.N. PW168290 will be new motor frame size.6 Add a 1 to # for iron or a 2 for stainless steel (example: model 10 with iron is 1003-01).
![Page 204: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/204.jpg)
198 victormfg.com
Repair Parts 9SECTION
Gas Equipment Catalog
Parts Details for Models F9C to F15C, FF9 to FF15C and F109 to F115
ReF# MFR# DeSCRiPtion qty webb#
1 7001- 031NC100A Hex Head Cap Screw 8 —
2
1001-091001-01001-21001-31001-41001-5
Cover—Model 9Cover—Model 10Cover—Model 12Cover—Model 13Cover—Model 14Cover—Model 15
111111
——————
310142
1014-12
Case Clearance Shim (.002 Red)
Case Clearance Shim (.003 Green)
As Req.As
Req.
181071
—
4 2-246 2, 3
2-247E2Case O-Ring (Non-Teflon®1)
Case O-Ring Teflon®111
——
5
1003-094
1003-04
1003-24
1003-34
1003-44
1003-54
Impeller—Model 9Impeller—Model 10Impeller—Model 12Impeller—Model 13Impeller—Model 14Impeller—Model 15
111111
—181060181062181063181064
—
6
113-CX_3
113-CXA113-CXB113-CXD113-CXE
Seal AssemblySeal AssemblySeal AssemblySeal AssemblySeal Assembly
11111
—181075181076181077181057
7
1004-1X
1004-11X
1004-2X
1004-21X
Seal Housing, Steel (Non-Teflon®1 O-Rings)
Seal Housing, SS (Non-Teflon®1 O-Rings)
Seal Housing, Steel (Non-Teflon®1 O-Rings)
Seal Housing, SS(Non-Teflon®1 O-Rings)
1
1
1
1
310362
—
—
—
81013
1013-1
Housing Adjustment Shim (0.010)
Housing Adjustment Shim (0.020)
As Req.As
Req.
181069
—
9 2-224_3 O-Ring (Housing) 1 —10 3442 Pipe Plug, 1/4” 1 —11 3444 Pipe Plug, 3/4” 1 —
ReF# MFR# DeSCRiPtion qty webb#
12
1002-091002-01002-21002-31002-41002-54206-094206-04206-24206-34206-44206-5
Case—Model 9Case—Model 10Case—Model 12Case—Model 13Case—Model 14Case—Model 15
Case—ANSI Flanged Model 9Case—ANSI Flanged Model 10Case—ANSI Flanged Model 12Case—ANSI Flanged Model 13Case—ANSI Flanged Model 14Case—ANSI Flanged Model 15
111111111111
————————————
13 1914-1 Nameplate 1 —
14 7012- 006SF019E Phillips Head Screw 6 – 32X1/4” 2 —
15 5002-281 Bearing Retainer Ring 1 —16 1238 Bearing Cap 1 —17 1006 Grease Seal 1 18106718 5102-118 Bearing Retainer Ring 1 —19 2758 Ball Bearing 1 18117620 5000-281 Bearing Retainer Ring 1 —
21 24972
2497-12#5 Woodruff Key, Steel#5 Woodruff Key, SS
11 —
22 12341234-1
ShaftShaft, Stainless Steel
11
181091—
23 3226 Key 1 —24 2759 Ball Bearing 1 18117725 1010-2 Frame 1 —
26 7002- 037NC087A Socket Head Screw 4 —
27 2158 Grease Zerk 2 —28 2159 Lubricap 2 —
1 Registered trademarks of the DuPont Company.2 Included with seal assembly/repair kit 113-CX_.3 _Denotes O-Ring Code.4 Prior to S.N. PR166727 motor part number was 3760.5 Starting with S.N. PW168290 will be new motor frame size.6 Add a 1 to # for iron or a 2 for stainless steel (example: model 10 with iron is 1003-01).
O-Ring Code
A Buna-N
B Neoprene ® 1
D Vitron ® 1
E Teflon ® 1
G Ethylene Propylene ® 1
K Kalrez ® 1
![Page 205: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/205.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Repair Parts
199
9SECTION
pu
mp
s/c
om
pr
es
so
rs
9
Parts Details For Stationary Coro-Vane® Pumps Models 521 and 1021
![Page 206: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/206.jpg)
200 victormfg.com
Repair Parts 9SECTION
Gas Equipment Catalog
Parts Details For Stationary Coro-Vane® Pumps Models 521 and 1021 (continued)
ReF# MFR# DeSCRiPtion qty webb#
1 1162-21201-2
Cam (521)Cam (1021)
11
181078181086
2 28322841
Case (521)Case (1021)
11
——
31172-2.53
1172-23
1206-34
2.5” Flange (521)2” Flange (521)
3” Flange (1021)
112
———
42-234_2, a
2-245_2
2-249_2
Flange O-Ring (521)Flange O-Ring 3” (1021)Flange O-Ring 4” (1021)
222
181148——
5 2-112_2 Adjusting Screw O-Ring 1 —6 2590 Flush Seal Plug 1/8” NPT 1 —7 2252 Relief Valve Adjusting Screw 1 —
8 11741207
Valve Cap (521)Valve Cap (1021)
11
——
9 1242-X1227
Relief Valve Spring & Guide (521)Relief Valve Spring Guide (1021)
11
——
10 2-224_2
2-228_2Relief Valve Cap O-Ring (521)
Relief Valve Cap O-Ring (1021)11
——
11 12411224
Relief Valve (521)Relief Valve (1021)
11
——
12 12421226
Relief Valve Spring (521)Relief Valve Spring (1021)
11
——
13 11701309
Cam Key (521)Cam Key (1021)
11
——
14 1168-71308-9
Blade (521)Blade (1021)
1010
—181094
15 116-1X1R1208-1X1R
Rotor & Shaft Assembly (521)Rotor & Shaft Assembly (1021)
11
—181089
16 1358 Grease Seal 2 —17 1164-1 Bearing Cap 2 —18 2158 Grease Zerk 1/8” NPT 2 —19 1769 Bearing Housing 2 —20 1343 Relief Fitting (Seal Vent) 2 —
21 1769-X_1, 2, a
1769-XR_1, 2, aSeal Assembly
Seal Assembly—Replacement22
181126181127
22 1163-28
1209-18Sideplate (521)
Sideplate (1021)22
——
23 1161-41205-4
Head (521)Head (1021)
22
——
242754-X27552754
Roller Bearing—CompleteBearing Inner RaceBearing Outer Race
222
———
25 2760-244 Retainer Ring 2 —26 1343 Relief Fitting (Grease) 2 —27 2-128_7 Shaft O-Ring 2 —28 1882 Seal Adapter Plate 2 —29 2-240_2 Adapter Plate O-Ring 2 —
30 2-261_2, a
2-268_2Case O-Ring (521)
Case O-Ring (1021)22
181153—
31 2270 1/4” Key 2 —32 2949 Nameplate 1 —33 3442 1/4” NPT Plug 1 —
ReF# MFR# DeSCRiPtion qty webb#
347001-031NC125A7001-037NC125A
Hex Head Bolt 5/16 – 18X1 – 1/4 (521)
Hex Head Bolt 3/8 – 16X1 – 1/4 (1021)
4
4
—
—
357001-037NC125A7001-037NC125A
Hex Head Bolt 3/8 – 16X1 – 1/4 (521)
Hex Head Bolt 3/8 – 16X1 – 1/4 (1021)
28
32
—
—
36 7001-037NC150A Hex Head Bolt 3/8 – 16X1 – 1/2 8 —
37 ———5 Retainer 2 —38 ———5 Seal Seat 2 —39 2-227_2 Seal Seat O-Ring 2 —40 2159 Lubricant #2 2 —41 1359 Lubricant Instruction Tag 2 —
42 7003-004DR0198
Round Head Plated Drive Screw 4X3/16 2 —
1 Seal assemblies are available in two forms: a. Complete seal kit including bearing housing, seat adapter plate, bearings, retainer ring, seal and O-Rings. Part number 1769-X_2. b. Field replacement seal assembly containing only the seal and O-Rings. Part number 1769-XR_2.2 _denotes O-Ring code
3 Optional flanges, (model 521): 1172-1.5 1/2” NPT 1172-1.5S 1/2” Weld 1172-2 2” NPT 1172-2S 2’ Weld 1172-2.5 21/2” NPT 1172.2.5S 2 1/2” Weld4 Optional flanges, (model 1021): 1206-3S 3” Weld 1206-4 4” NPT 1206-4S 4’ Weld5 Not available separately.6 Neoprene®, Viton®, and Teflon® are registered trademarks of the Dupont company.7 Available in Buna-N only.8 Sideplate replacement instructions.
O-Ring Code
A Buna-N
B Neoprene ® 6
D Vitron ® 6
E Teflon ® 6
![Page 207: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/207.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Repair Parts
201
9SECTION
pu
mp
s/c
om
pr
es
so
rs
9
29 (15 ft•lb)
(25 ft•lb)
28 (60 ft•lb)
28 (60 ft•lb)
25 (25 ft•lb)
22
12
4
Inlet
Outlet
4
See repair/re-build kits.
CAUTION: Always relieve pressure in the unit before attempting any repairs.
Note: Hydraulic motor is not shown.
Parts Details For Models Z/ZH3200
O-Ring Code
A Buna-N
B Neoprene ® 1
D Vitron ® 1
E Teflon ® 1
ReF# MFR# DeSCRiPtion qty webb#1 4495-X2R Rotor Shaft Assembly 1 —2 4242 Cam 1 1812173 4232 Vane5 6 2542354 4231 Sideplate 2 —5 4488 Head 2 —6 4239 Case 1 —7 4417 Bearing Cap 2 —8 4438 Grease Seal 2 —9 4435 Mounting Ring 2 —
104439
4439-14439-2
Bearing Shim (.002) RedBearing Shim (.010) BrownBearing Shim (.020) Yellow
AsReq.
———
11 2270 Shaft Key 2 —12 4431-X_a, 2 Mech. Seal Assembly4 2 25423613 2754 Bearing Outer Race 2 —14 4432 Thrust Bearing Assembly 2 —15 2760-244 Retainer Ring 2 —16 1174-2 Relief Valve Cap 1 —17 1359 Lubrication Instruction Plate 2 —18 4441 Grease Seal 2 —
19 7012- 006SF019E Screw 8 —
20 — Not Shown — —21 — Not Shown — —
ReF# MFR# DeSCRiPtion qty webb#22 2-262_ O-Ring—Case4 2 —23 2-224_ O-Ring_Relief Valve Cap4 1 —24 1240 Relief Valve Spring 1 —
25 7001- 037NC150A Bolt—3/8 – 16X11/2” Hex Head 16 —
26 2158 1/8” NPT Grease Zerk 2 —27 1343 1/8” NPT Relief Fitting 4 —
28 7001- 050NC150A Bolt—1/2 – 13X11/2” Hex Head 16 —
29 7001- 031NC125A Bolt—5/16 – 16X11/4” Hex Head 4 —
30 1241 Relief Valve 1 —31 4243 Outlet Flange—2” NPT Ell2 1 —32 4241 Cam Key 1 —33 3253 Cam Key Pin 1 —34 3442 1/4” NPT Pipe Plug 1 —35 4262-X Vane Driver 3 25423736 2-234_ O-Ring—Flange4 1 —37 2159 Lubricap 2 —38 1172-2 Aux. Inlet Flange—2” NPT3 1 18108439 2649 Nameplate 1 —40 4248 Relief Valve Nameplate 1 —
41 4282 Relief Valve Shim As Req. —
42 7206-037A 3/8” Lockwasher 8 —1 Registered trademarks of the DuPont Company.2 Optional 1.5” NPT (part# 1172-1.5), 1.5” WF (1172-1.5S), 2” WF (1172-2S), 2” NPT (1172-2) and 1.5” NPT EII (1942).3 Optional 1.5” NPT (part# 1172-1.5), 1.5” WF (1172-1.5S), 2” WF (1172-2S), blind (1920-3) and 2” NPT EII (4243).4 _denotes O-Ring code. See chart above.6 Slots in varies must face TOWARDS the direction of rotation.
![Page 208: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/208.jpg)
202 victormfg.com
Repair Parts 9SECTION
Gas Equipment Catalog
See repair/re-build kits.
CAUTION: Always relieve pressure in the unit before attempting any repairs.
Note: Hydraulic motor is not shown.
Parts Details For Models Z3500
O-Ring Code
A Buna-N
B Neoprene ® 1
D Vitron ® 1
E Teflon ® 1
ReF# MFR# DeSCRiPtion qty webb#1 2-228 O-Ring4 1 —2 2-245 O-Ring4 1 —3 2-259 O-Ring4 1 —4 2-268 O-Ring4 2 —5 1206-4 Inlet Flange—3” NPT2 1 —6 1207-2 Relief Valve Cap 1 —7 1208-1X6R Rotor Shaft Assembly 1 1810898 1224 Relief Valve 1 —9 1309 Cam Key 1 —
10 1343 Grease Relief Fitting 4 —11 1359 Lubrication Plate 2 —12 2158 Grease Zerk 2 —13 2159 Lubricap 2 —14 2270 Shaft Key — 1/4” 1 —15 2649 Nameplate 1 —16 2754 Outer Bearing 2 —17 2760-244 Retainer Ring 2 —18 3253 Cam Key Pin 2 —19 3442 Pipe Plug—1/4” NPT 2 —20 3935 Sideplate 2 —21 3936 Vane5 6 —22 4248 Relief Valve Warning Tag 1 —23 4417 Bearing Cap 2 —24 4432 Thrust Bearing Assembly 2 —
ReF# MFR# DeSCRiPtion qty webb#25 4435 Thrust Bearing Mounting Ring 2 —26 4438 Greas Seal/Oil Seal 2 —27 4439 Bearing Cap Shim—0.002” 2 —28 4439-1 Bearing Cap Shim—0.010” 2 —29 4439-2 Bearing Cap Shim—0.020” 2 —30 4441 Grease Seal 2 —31 4431-X2 Mechanical Seal Assembly4 2 —32 4985 Coro-Vane Shaft Cover 1 —
33 7001- 037NC125A Hex Head Bolt 24 —
34 7001- 037NC150A Hex Head Bolt 18 —
35 7001- 037NC175A Hex Head Bolt 4 —
36 7012- 006SF019E Screw 9 —
37 7012- 010SF050E Screw 2 —
38 7206-037A Lock Washer—0.375” 8 —39 5534 Head 2 —40 5537 Case 1 —41 5539 Cam 1 —
42 5538 Outlet Flange—3” NPT Elongated3 1 —
43 5548 Spring 1 —44 5554-X Vane Driver 6 —
1 Registered trademarks of the DuPont Company.2 Optional 1.5” NPT (part# 1172-1.5), 1.5” WF (1172-1.5S), 2” WF (1172-2S), 2” NPT (1172-2) and 1.5” NPT EII (1942).3 Optional 1.5” NPT (part# 1172-1.5), 1.5” WF (1172-1.5S), 2” WF (1172-2S), blind (1920-3) and 2” NPT EII (4243).4 _denotes O-Ring code. See chart above.6 Slots in varies must face TOWARDS the direction of rotation.
![Page 209: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/209.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Repair Parts
203
9SECTION
pu
mp
s/c
om
pr
es
so
rs
9
Repair Kits and Spare Parts For Stationary Coro-Vane® PumpsC51/F51 Standard Repair Kits(no kit available) C51/F51 Additional Spare Parts
521 Repair Kit 2904-X21 521 Additional Spare Parts
F1521 Additional Spare Parts
1021/F1021 Additional Spare Parts
MFR# DeSCRiPtion qty webb#2296-1X_5 Seal Assembly 1 —2451-2 Vane 8 —2-154_ Case O-Ring 2 —2491 Sideplate 2 —
MFR# DeSCRiPtion qty webb#2492-X Rotor & Shaft Assembly 1 —2471 Roller Bearing 2 —
MFR# DeSCRiPtion qty webb#1163-2 Sideplate 2
181179
1168-7 Vane 101358 Grease Seal 21769-XRA Seal Assembly (Replacement) 22-112A O-Ring, Buna-N 12-224A O-Ring, Buna-N 12-227A O-Ring, Buna-N 22-234A O-Ring, Buna-N 22-261A O-Ring, Buna-N 22010 Flange Gasket 32014 Grease Seal, Thrust 12754-X Roller Bearing 2
MFR# DeSCRiPtion qty webb#1166-1X1R Rotor & Shaft Assembly 1 —1162-2 Cam (Liner) 1 181078
F1521 Repair Kit 2907-X31
MFR# DeSCRiPtion qty webb#1358 Grease Seal 2 —1769-XRA Seal Assembly (Replacement) 2 —2-234A O-Ring, Buna-N 3 —2-238A O-Ring, Buna-N 1 —2-245A O-Ring, Buna-N 1 —2-249A O-Ring, Buna-N 1 —2-268A O-Ring, Buna-N 2 —2014 Grease Seal, Thrust 1 —2754 Bearing Outer Race 2 —3209 Ball Bearing 1 —3476-L Sideplate, Left 1 —3476-R Sideplate, Right 1 —3477 Vane 6 —
MFR# DeSCRiPtion qty webb#3350-X1R Rotor & Shaft Assembly 1 —1792-1 Cam (Liner) 1 —
1021/F1021 Repair Kit 2906-X2MFR# DeSCRiPtion qty webb#1209-1 Sideplate 2
181182
1308-9 Vane 101358 Grease Seal 21769-XRA Seal Assembly (Replacement) 22-112A O-Ring, Buna-N 12-228A O-Ring, Buna-N 12-245A O-Ring, Buna-N 22-249A O-Ring, Buna-N 22-268A O-Ring, Buna-N 22014 Grease Seal, Thrust 12754-X Roller Bearing 2
MFR# DeSCRiPtion qty webb#1208-1X1R Rotor & Shaft Assembly 1 1810891201-2 Cam (Liner) 1 181086
1 All repair kits have Buna-N O-Rings which are suitable for both LPG and NH3 applications.
![Page 210: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/210.jpg)
204 victormfg.com
Repair Parts 9SECTION
Gas Equipment Catalog
Repair/Re-build KitsZ2000, ZH2000, ZX2000, ZXH2000 Repair Kit 3193-X1
Z4200, ZH4200, Z4500 Repair Kit 3197-X1
Z3500 Repair Kit 3195-X2
Z3200, ZH3200 Repair Kit 3195-X1
MFR# DeSCRiPtion qty webb#2-224A O-Ring, Buna-N 1 —2-231A O-Ring, Buna-N 2 —2754-X Roller Bearing 2 —4262-X Vane Driver 3 —4428 Vane 6 —4431-XA2 Seal Assembly 2 —4432 Thrust Bearing 2 —4435 Thrust Bearing Mounting Ring 2 —4439 Bearing Cap Shim (0.002) 8 —4439-1 Bearing Cap Shim (0.010) 2 —4439-2 Bearing Cap Shim (0.020) 2 —4441 Grease Seal 2 —2270 Shaft Key 1 —
MFR# DeSCRiPtion qty webb#2-231A O-Ring, Buna-N 1 —2-234A O-Ring, Buna-N 2 —4460-X Roller Bearing 2 —4449-X Vane Driver 5 —4448 Vane 6 —4464-XA2 Seal Assembly 2 —4453 Thrust Bearing 2 —4454 Thrust Bearing Mounting Ring 2 —4458 Bearing Cap Shim (0.002) 8 —4458-1 Bearing Cap Shim (0.010) 2 —4458-2 Bearing Cap Shim (0.020) 2 —4463 Grease Seal 2 —4459 Shaft Key 1 —
Z2000, ZH2000, ZX2000, ZXH2000Re-Build Kit 3194-X1 includes all items in the Repair Kit plus the following:
Z3200, ZH3200 Re-Build Kit 3196-X1 includes all items in the Whole Kits Repair Kit (#181238)plus the following:
Z3500 Re-Build Kit 3196-X2includes all items in the Repair Kit plus the following:
Z4200, ZH4200, Z4500 Re-Build Kit 3198-X1 includes all items in the Repair Kit plus the following:
MFR# DeSCRiPtion qty webb#4414 Cam 1 —4427 Sideplate 2 —
MFR# DeSCRiPtion qty webb#4242 Cam 1 1812174231 Sideplate 2
MFR# DeSCRiPtion qty webb#5539 Cam 1 —3935 Sideplate 2 —
MFR# DeSCRiPtion qty webb#4443 Cam 1 —4446 Sideplate 2 —
MFR# DeSCRiPtion qty webb#2-228A O-Ring, Buna-N 2 —2754-X Roller Bearing 2 —5554-X Vane Driver 3 —3936 Vane 6 —4431-XA2 Seal Assembly 2 —4432 Thrust Bearing 2 —4435 Thrust Bearing Mounting Ring 2 —4439 Bearing Cap Shim (0.002) 8 —4439-1 Bearing Cap Shim (0.010) 2 —4439-2 Bearing Cap Shim (0.020) 2 —4441 Grease Seal 2 —2270 Shaft Key 1 —
MFR# DeSCRiPtion qty webb#2-224A O-Ring, Buna-N 1
181237
2-234A O-Ring, Buna-N 22754-X Roller Bearing 24262-X Vane Driver 34232 Vane 64431-XA2 Seal Assembly 24432 Thrust Bearing 24435 Thrust Bearing Mounting Ring 24439 Bearing Cap Shim (0.002) 84439-1 Bearing Cap Shim (0.010) 24439-2 Bearing Cap Shim (0.020) 24441 Grease Seal 22270 Shaft Key 1
1 All repair kits have Buna-N O-Rings which are suitable for both LPG and NH3 applications.
![Page 211: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/211.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Generators
205
10SECTION
Mis
c E
qu
ipM
En
t
10
Guardian® Series Standby GeneratorsThe G3B is a power gas burner for natural or propane gas—completely assembled, using premix combustion and hot surface ignition with lame rectification flame sensing.
Features:• True Power electrical technology• Two line LCD Tri-lingual digital Nexus controller• Electronic governor• External main circuit breaker and system status LED indicators
• Flexible fuel line connector• Composite mounting pad• Natural gas or LP gas operation• 3 Year limited warranty• UL 2200 listed
MFR# DESCRIPTION WEBB#GRC5882 AIR CLD GENERATOR 8KW STEEL 361729GRC5883 AIR CLD GENERATOR 10KW STEEL 361730GRC5884 AIR CLD GENERATOR 14KW STEEL 422548GRC5885 AIR CLD GENERATOR 17KW STEEL 361732GRC5886 AIR CLD GENERATOR 17KW ALUM 422549GRC5887 AIR CLD GENERATOR 20KW ALUM 422550GRCQT02516 LIQ COOLED GENERATOR 25KW STEEL 361734
MFR# DESCRIPTION WEBB#GRC5793 IX2000 PORT GEN 2000 WATTS 422562GRC5939 GP5500 PORT GEN 5500 WATTS 422552GRC5940 GP6500 PORT GEN 6500 WATTS 422553
MFR# DESCRIPTION WEBB#GRCRTS10EZA1 10-CIRC LOAD CENTER ATS NEMA 1 361743GRCRTS12EZA1 12-CIRC LOAD CENTER ATS NEMA 1 361744GRCRTS14EZA1 14-CIRC LOAD CENTER ATS - NEMA 1 422564GRCRTS16EZA1 16-CIRC LOAD CENTER ATS NEMA1 361745GRCRTSD100A3 100 AMP SERV ENTR 120/240 1 NEMA 3R 368691GRCRTSD200A3 200 AMP SERV ENTR 120/240 1 NEMA 3R 361746GRCRTSN100A3 100 AMP 120/240 1 NEMA 3R 422567GRCRTSX200A3 200 AMP 120/240 1 NEMA 3R 422571GRCRTSN100G3 100 AMP 120/208 3 NEMA 3R 422568GRCRTSN200G3 200 AMP 120/208 3 NEMA 3R 422572GRCRTSN200J3 200 AMP 120/240 3 NEMA 3R 422573GRCRTSS200A3 PWR MGR 200A AMP 120/240 1 NEMA 3R 422566
Generac Whole-House Propane / Natural Gas Generators
Generac Load Centers
Generac Portable Gasoline Generators
20KW Aluminum
14KW Steel
![Page 212: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/212.jpg)
206 victormfg.com
Generators 10SECTION
Gas Equipment Catalog
ETQ Generators
Generator Usage Chart
MFR# DESCRIPTION WEBB#IN1800I 1800W CLOSED FRAME GASOLINE 411953TG32P12 4000W OPEN FRAME GASOLINE 411954TG72K12 8250W OPEN FRAME GASOLINE 420781TP30P11 3500W OPEN FRAME LP 411955PG60B12 7000W OPEN FRAME LP 435132W0001-T40-00 WHEEL KIT FOR TP30P11 415973
Nat gas usage (btu/hr 1000's)
LP usage gaL/hr (btu/hr 1000's)
air cooLed haLf Load haLf Load haLf Load haLf Load7 KW 66 119 .82 (75) 1.47 (135)10 KW 102 156 1.25 (115) 1.93 (178)13 KW 156 220 1.55 (143) 2.18 (200)16 KW 173 245 1.59 (147) 2.51 (231)18 KW 181 262 1.97 (182) 2.85 (262)
Nat gas usage (btu/hr 1000's) LP usage gaL/hr / (btu/hr 1000's)
Liquid cooLed exercise haLf Load fuLL Load exercise haLf Load fuLL Load18 KW 48 165 278 .52 (48) 1.8 (166) 3.04 (280)20 KW 60 188 315 .65 (60) 2.05 (189) 3.44 (317)25 KW 60 253 437 .65 (60) 2.77 (255) 4.81 (443)30 KW 56 281 437 .65 (60) 3.17 (293) 5.0 (461)45 KW 102 373 720 1.11 (102) 4.07 (375) 7.86 (723)60 KW 123 500 960 1.34 (124) 5.46 (503) 10.48 (965)70 KW 110 499 1020 1.20 (111) 5.46 (503) 11.17 (1028)80 KW 131 600 1154 1.45 (134) 6.64 (611) 12.78 (1176)100 KW 140 713 1374 1.53 (141) 7.81 (719) 15.05 (1385)130 KW 135 927 1786 1.48 (137) 10.15 (934) 19.56 (1800)150 KW 155 1070 2061 1.70 (157) 11.72 (1079) 22.57 (2077)
IN1800I
TG72K12 PG60B12
TG32P12 TP30P11
![Page 213: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/213.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Gas Burner
207
10SECTION
Mis
c E
qu
ipM
En
t
10
EZ-Gas Power Gas Burner50K - 275K BTU
G3B Power Gas Burner60K - 180K BTU
The G3B is a power gas burner for natural or propane gas—completely assembled, using premix combustion and hot surface ignition with lame rectification flame sensing.
Features:• Converts from propane to natural gas with just an orifice change— no conversion kit needed.• Factory-packaged with combustion control and gas fuel train.• 60,000 to 180,000 Btuh —ideal for small to large homes.• Quiet and clean.• Dependable, hot surface ignition for quick, clean light-off.• Compact, efficient flame pattern.• Does not require a refractory liner—fires with or without a combustion chamber.• Ideal for high-efficiency wet-based boilers.• Superior for use in 2, 3, 4 or 5-section boilers.• Calibrated air throttle for easy adjustment.• Universal mounting flange.• Low-energy motor—only 0.40 amp.• Includes 1-year warranty.
Features:• Converts from propane to natural gas with just an orifice change— no conversion kit needed.• Fires negative or positive chambers from 50,000 to 275,000 Btuh input.• Provides dependable, direct-spark ignition of main flame—for quick, clean light offs.• Comes standard with time-tested solid state ignition and state-of-the-art microprocessor control technology.• Factory-packaged with combustion control and gas fuel train.• Shipped completely assembled and wired—for “EZ” installation and start-up.• Diagnostic LED lights annunciated operating mode: Self-check, Flame-on, Recycle, Lockout and Latch-up.• High-efficiency, compact flame pattern design ensures clean, quiet operation.• Does not require a refractory liner—fires with or without a combustion chamber.• Available with custom welded air tube flange (and/or optional pedestal) to accommodate most appliance mounting requirements.• Includes 1-year warranty.
MFR# DESCRIPTION WEBB#74245 G3B With 6” Tube 18522174252 G3B With 9” Tube 95235
MFR# DESCRIPTION WEBB#9859210AFR1A EZ-Gas 10” A 150K - 275K 3794879859210BFR1 EZ-Gas 10” B 50K - 175K 379488
![Page 214: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/214.jpg)
208 victormfg.com
Vaporizers 10SECTION
Gas Equipment Catalog
MFR# WEBB# CaPaCITyALT1206H 424131 120 gal/hr (10.9 MBH)ALT4040H 424133 40 gal/hr (3.6 MBH)ALT8040H 424132 80 gal/hr (7.3 MBH)
Direct Fired LPG VaporizersA propane vaporizer is actually a boiler. Instead of boiling water, it boils propane. It may sound strange that heat is required to vaporize propane when propane will boil at -44 F, but, when propane vaporizes by expansion alone, it causes a refrigeration action. In applications with high propane demand, the uncontrolled vaporization would freeze valves and burner nozzles. Therefore, heat is required to offset the refrigeration action.Direct fired vaporizers use a portion of the propane they vaporize to supply the heat for the vaporization process. AES direct fired vaporizers can be used to vaporize all forms of LPG (Liquefied Petroleum Gas), including Propane, Butane, Propylene, etc.• For Propane, Butane, & other LPG• Two-Stage Burner• Dual Liquid Level Control• Piezo Ignitor
Comparative Thermal Value of FuelsNatural Gas ........................................................100,000 BTU’s =1 ThermFuel Oil ..............................................................42 Gallons = 1 barrel
Gas Conversion Factors1 Cubic Foot (CF) ...............................................Approximate 1,000 BTU’s100 CF ................................................................100,000 BTU’s1 Therm .............................................................100,000 BTU’s10 Therms ..........................................................1 Decartherm (DTH)1 DTH ................................................................1,000,000 BTU’s1 DTH ................................................................1 MM BTU
approximate ConversionPropane/Gallon .................................................91,500 BTU’s = .915 Therms/GallonButane/Gallon ...................................................103,000 BTU’s = 1.03 Therms/Gallon#2 Heating Oil/Diesel/Gallon ..........................138,500 BTU’s = 1.385 Therms/Gallon#6 Fuel Oil/Barrel .............................................6,350,000 BTU’s = 63.5 Therms/GallonCoal (Short Ton) ................................................21,900,000 BTU’s = 219 Therms/Short Ton1 Truck & Trailer of Propane (9,300 Gallons) = 8,510 Therms1 Truck & Trailer of Butane (9,300 Gallons) = 9,274 Therms1 Truck & Trailer of Diesel (8,000 Gallons) = 11,080 Therms1 Truck & Trailer of #6 Fuel (7,000 Gallons) = 10,500 Therms
Convert Cents/Gallon to $/MM BTUMultiply Cents/Gallon by:Ethane ................................................................15.24 Gallons/MM BTUPropane ..............................................................10.93 Gallons/MM BTUNormal Butane ..................................................9.71 Gallons/MM BTUIso-Butane ..........................................................10.12 Gallons/MM BTUMixed Butane (75/25) ........................................9.81 Gallons/MM BTUNatural Gasoline ................................................8.00 Gallons/MM BTU#2 Oil .................................................................7.22 Gallons/MM BTU
Convert $/Bbl to $/MM BTUDivide $Bbl by:#6 Oil .................................................................6.35 MM BTU/Barrel#6 Oil .................................................................151,190 MM BTU/Gallon
![Page 215: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/215.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004 209
10M
isc
Eq
uip
MEn
t
10
Disconnects
Burnaby Gas Outlet BoxModel #G0101-5Completely enclosed in a UV and fire protectant PVC box, manufactured to ISO 9220 standard, the gas outlet is an ideal means of safely and securely connecting your gas barbecue, patio heater, stove or dryer directly to your residential gas supply.• Eliminates refilling tanks, gas identification• Quick disconnect safety shutoff with easy access• C/W standoffs for siding installation• CGA & AGA approved for Indoor/Outdoor use• Approved for temperatures to -40°• Inlet connection – 3/8” N.P.T.• Hose connection – 3/8” Quick Disconnect• 75 MBH natural gas/118 MBH• Stainless models have lockable door
MFR# DESCRIPTION WEBB#G0101-SS-50 1/2” Surface Mount SS 283797GR0101-SS 3/8” Recessed Mount SS 283798GR0101-SS-50 1/2” Recessed Mount SS 283799G0101-DBL-SS 1/2” Surface Mount Double Connector 283800G0101-5W-50 6” X 41/2” X 21/2”, 1/2” Surface Mount, White 191025
MFR# DESCRIPTION WEBB#MXTGC10AA01 Plug1 Gas Outlet 412565
MFR# DESCRIPTION WEBB#SAE38X38MUN 3/8” Female X Male Union And a hose:VCT50A1900030 6’ Hose 370042VCT50A1900100 12’ Hose 370041VCT50A1900101 18’ Hose 370040
To complete this installation, add:
Gas Outlet
Hansen Gas-Mate CouplingOne-way shut-off Safety Couplings are designed for LP and natural gas applications where 3/8”, 1/2”, 3/4”, 1”, and 11/4” hose is used. 1/2 PSI Max Pressure.
MFR# FEMaLE END CONN. DIMENSIONS WEBB#100-006 3/8” FPT, Socket Only 2.44 X 1.13 X 1.00 202616100-008 1/2” FPT, Socket Only 2.84 X 1.38 X 1.13 182153100-010 3/4” FPT, Socket Only 3.17 X 1.75 X 1.50 182146100-506 3/8” FPT, Plug Only 1.59 X 0.94 X 0.81 182158100-508 1/2” FPT, Plug Only 1.94 X 1.16 X 1.00 182154100-510 3/4” FPT, Plug Only 2.06 X 1.52 X 1.31 182147
![Page 216: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/216.jpg)
210 victormfg.com
10SECTION
Gas Equipment Catalog
Gas Lights
Lights
Rutland Fireplace Products
Galaxy Lights By FaulkMFR# DESCRIPTION WEBB#VCT2703 Single Wall Light 316096VCT2705 Double Wall Light 367629VCT4GLOBE Glass Globe 316225
MFR# DESCRIPTION WEBB#F220325 Light Indoor (Gray) 395850F220300 Light Indoor (Brass) 396327F220353 Soft Tie on Mantle 395846F220351 Performed Mantle 395848F220370 Chandelier Kit 395849F220330 Glass Globe 395843
MFR# DESCRIPTION WEBB#VCT304 CHIMNEY PAINT SS 401840VCT565 WHT OFF GLASS CLEANER 401841VCT570-6 GAS LOG SOOT REMOVER 401844VCT585 GLW EMBRS 12OZ TUB 433550VCT587 ROCK WOOL 401839VCT595 LAVA ROCK 401838VCT63-G FIREPLACE MORTAR GRAY 408107VCT641 SEAL IT RIGHT 800F BLK LATEX 401843VCT82 FIREPLACE GLASS CLEANER 401842VCT83-6 BRICK & STOVE CLEANER 408108
![Page 217: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/217.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Serviceman’s Tools
211
11SECTION
To
ols
& C
hem
iCa
ls
11
Bee Bopper IIWasp and Hornet Spray#61011
Mfr# Size Webb#VCT61011 14 oz. 193250
Beware of the wasp with an attitude. Bee Bopper II will knock him right out of the sky. With Bee Bopper II, you can spray the nest from 20 feet away. Bee Bopper II kills bees and hornets too.
ARI
Propane Flare• Electronic Ignition and proof
of flame.• Safety feature offers automatic
relight attempt — complete shutdown if unsuccessful.
• Burns up to 529 gallons per hour.• Burns liquid or vapor propane.• Over 48,000,000 BTU/hr
(1/2” Flare).• Flare burner stands 12’
above ground surface• 12’ power cord for 115 volt A.C.• 20’ remote switch cord.• Stable triangular base.• Setup in 5 minutes.
Mfr# Size bTU/hr GalS/hr WeiGhT Webb#PF-12 LPS 1/4” Flare 6,900,000 Burns 75 100.5 lbs —PF-38 LPS 3/8” Flare 38,000,000 Burns 416 103.0 lbs —PF-16 LPS 1/2” Flare 48,300,000 Burns 529 105.5 lbs —
Available in three line sizes1/4” • 3/8” • 1/2”
Aim & Flame LightersMfr# DeSc. Webb#VCTAF Childproof 184412VCTHW6T — 266447
Leak Detector
Dispenser With Brush
8 oz. Bottle & DauberGallon
Mfr# DeScripTion Webb#TSTLTG4 All Season, Gallon 184312TSTTLPINTUNLABE 16 oz. Bottle With Brush 184310TSTBTL8DBRUNPRI 8 oz Bottle With Dauber 184311TSTSTL16CYLUNPR 16 oz. Bottle With Spray 184309
Leak Tester KitMfr# DeScripTion Webb#VCTPTK Tester Gas Kit 315690
LeakDetector
Mfr# DeScripTion Webb#HER45-801 8 oz. 11293
Match LighterMfr# Webb#Z6-413 184435
Test Gauge Kit
Mfr# DeScripTion Webb#PIGME295-1 1/8” MPOL X FPOL, No Plug 303222VCT18SHVLV 1/8” Union MPT Half 430102VCTPTG Pressure Test Gauge (0 – 300#) 394983RIT00706 Hose Only 379916
![Page 218: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/218.jpg)
212 victormfg.com
Serviceman’s Tools 11SECTION
Gas Equipment Catalog
1212 KIT
This kit provides the equipment necessary for checking regulator delivery pressure (low pressure) at the appliances. The basic set contains a 2434A-2 low pressure gauge and a 3 foot — 3/16” O.D. flexible synthetic rubber tube. Adapters are also available.
Low Pressure Test Set
Water Manometer KitThe water manometer kit is especially suited for use with low pressure LP-Gas systems. It is ideal for pressure checks downstream of the low pressure regulator and at the appliances.
Dwyer
Series 2000 Magnehelic Differential
Presssure Gauge
High Pressure Gauge AdapterDesigned for testing high pressure lines. Adapter has 0 to 300 PSIG gauge. A bleeder valve allows you to bleed down to correct pressure during pressure tests.
2434A
2962
Mfr# DeScripTion Webb#2434A Test Kit 162825SJIGPTK Test Kit 2049821328 3/8” OD Adapter 1628161331 1/2” OD Adapter 1628171332 5/8” OD Adapter 162818
Mfr#inleT
connecTionoUTleT
connecTion
preS-SUre
GaUGe ranGe (pSiG) Webb#
2962 Soft Nose M. POL F. POL 0 to 300 162829
Mfr# DeScripTion Webb#1212 KIT Flexible Tube Water Manometer Kit 162815
Mfr# DeScripTion Webb#DWY1222-16 U Tube Manometer 185267
Mfr# DeScripTion Webb#DWY2030 0-30” Magnehelic Differential Gauge 2251109DWYA432 Carry Case/Hoses for 2030 Gauges 359347
MetroTel Corp Cable Hound DSPThe Cable Hound DSP is an electronic device designed to accurately locate and determine depth of buried cable or metallic pipe. Features:• Improved depth and distance
capabilities.• New receiver with digital signal processing (DSP).• Auto-Off switch saves battery life.• Quality padded headphones included.• Improved, more convenient case.
EM150Features:• Measures postitive and
negative pressure 20” water gauge.
• Auto power off.• Rubber-boot with built-in
magnet.• .05” resolution below
9.95”.
EM200Features:• Dual scale: 60” water
gauge and 150 mBar .01” wg resolution below 9.99”.
• Ruggedized with sturdy metal fittings.
• Rubber-boot with built-in magnet.
• Min/Max.• Data hold.• Auto power off.• Back-lit display.• One year limited
warranty.
Mfr# Webb#EM150 193481EM200 284231
EM150 EM200
Quick Look 72Mfr# Webb#720001W 360275
Mfr# Webb#MT99-0118 308931
![Page 219: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/219.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ap
pen
dic
es
LP Container Requirements
213
12SECTION
12
12) Open the service valve and start to fill the tank with propane. CAUTION: After the tank pressure has been normalized, close the outage valve (if it was opened after the pressure was normalized), the service valve and the fill hose valve. NOTE: The appropriate amount of propane to normalize the vacuum pressure in the tank will vary depending on the volume of the tank. If liquid is used, 1 to 4 gallons of propane is required for all tanks up to 1000 gal. water capacity. If vapor is used, wait until there is no longer an audible transfer of vapor from the filler hose to the tank. 13) Bleed off the fill connector pressure and disconnect.
The Tank Has Now Been Prepared For Service.• To transport the tank after preparation process, remove
all propane gas in the tank in excess of the amount of propane permitted to be transported under applicable regulations, including those of the U.S. Department of Transportation.
• Once the tank has been safely set for service, you may continue the filling process through the fill valve by re- moving the seal and cap of the fill valve and using your normal safe filling procedures.
CAUTION: The initial fill must be to the maximum allowable liquid level to counteract the possible depletion of ethyl mercaptan in the tank.
• If you did not do so earlier, you may also inject methanol into the tank at this point by including an injection device in your fill line.
• Future fillings should be made through the fill valve.
CAUTION:• Do not remove seals on valves before being properly
instructed on how to initially fill a vacuum pre-purged propane tank.
• Do not let any air enter the propane tank. If air is allowed in the tank before the pressure is normalized, it must be re-purged with propane vapor in accordance with NFPA Pamphlet #58 and government regulatory requirements.
• Do not remove cap from fill valve until the vacuum has been neutralized. Begin filling through the service valve (a/k/a the multivalve) for the first fill or at least until the vacuum is neutralized.
• Do not open the outage valve until the pressure in the tank has normalized or a positive pressure has been achieved in the tank.
• The presence of a vacuum in the tank does not eliminate the need for the introduction of methanol into the tank.
• Never prepare the propane tank for service on a customer’s property, but always at the bulk plant site or some other safe location.
1) Verify that a vacuum exists in the tank.2) Remove the seal wrap from the service valve and verify that the service valve hand wheel is tightly closed.3) Connect a vacuum pressure gauge to the service valve outlet connection and open the hand wheel.4) Visually check the vacuum pressure gauge dial for the presence of a vacuum.5) Close the service valve and disconnect the vacuum pressure gauge. NOTE: If the vacuum is not in accordance with NPGA Safety Bulletin No. 133-89(a), the container must be re-purged with propane vapor.
6) Add methanol to the propane tank by connecting a hose to the POL outlet of the service valve.7) Submerge the other end of the hose in a safety container that has been filled with the required measure of methanol.8) Gradually open the service valve and the metha- nol will be drawn into the tank to partially fill the vacuum that exists.9) To prevent air from getting into the propane tank, close the service valve as soon as the measured amount of methanol has been removed from the safety container.10) Disconnect the methanol hose from the POL of the service valve.11) Connect the propane fill hose to the POL connector on the service valve.
Filling Instructions for the Vacuum Pre-Purged Propane Tank
![Page 220: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/220.jpg)
214 victormfg.com
LP Container Requirements 12SECTION
Gas Equipment Catalog
Storage Within Residential Buildings. Storage of cylinders within a residential building, including the basement or any storage area in a common basement storage area in multiple-family buildings and attached garages, shall be limited to cylinders each with a maximum water capacity of 2.7 lb (1.2kg) and shall not exceed 5.4-lb (2.4-kg) aggregate water capacity for smaller cylinders per each living space unit. Each cylinder shall meet DOT specifications.
5.4 Storage Outside of Buildings. Location of Storage Outside of Buildings. Storage outside of buildings for cylinders awaiting use, resale, or part of a cylinder exchange point shall be located as follows.5.4.1.1 At least 5 ft. (1.5 m) from any doorway or opening in a building frequented by the public where occupants have at least two means of egress as defined by NFPA 101, Life Safety Code. For buildings, or sections of buildings, having only one means of egress, at least 10 ft. from the doorway or opening.5.4.1.2 At least 20 ft. from any automotive service station fuel dispenser.5.4.1.3 In accordance with Table 5.4.1.3 with respect to the following:(1) Nearest important building or group of buildings.(2) Line of adjoining property that may be built upon. (3) Busy thoroughfares or sidewalks. (4) Line of adjoining property occupied by schools,
churches, hospitals, athletic fields, or other points of public gathering.
(5) Dispensing station. Exception: Cylinders in the filling process shall not be considered to be in storage.
5.4.2 Protection of Cylinders.5.4.2.1 Cylinders at a location open to the public shall be protected by either of the following:(1) An enclosure in accordance with 3.3.6(a)(2) A lockable ventilated metal locker or rack that
prevents tampering with valves and pilferage of the cylinder.
Liquified Petroleum Gas Code*
HORIzONTAL DISTANCe TO . . .QUANTITy OF LP-GAS STOReD (1) & (2) (3) & (4) (5) LB kG FT m FT m FT m £720 £227 0 0 0 0 5 1.5 721 to 2,500 227+ to 1,134 0 0 10 3 10 3 2,501 to 6,000 1,134+ to 2,721 10 3 10 3 10 3 6,001 to 10,000 2,721+ to 4,540 20 6.1 20 6.1 20 6.1 >10,000 >4,540 25 7.6 25 7.6 25 7.6
5.4.2.2* Protection against vehicle impact shall be provided in accordance with good engineering practice where vehicle traffic normally is expected at the location.5.4.3 Alternate Location and Protection of Storage. Where the provisions of 5.4.1 and 5.4.2.1 are impractical at construction sites or at buildings or structures undergoing major renovation or repairs, alternate storage of cylinders shall be acceptable to the authority having jurisdiction.5.5* Fire Protection. Storage locations, where the aggregate quantity of propane stored is in excess of 720 lb. (327 kg), shall be provided with at least one approved portable fire extinguisher having a minimum capacity of 18 lb. (9.2 kg) dry chemical with B-C rating. The required fire extinguisher shall be located no more than 50 ft. (15 m) from the storage location.
Use of Liquid Volume Correction Factors, Table F.3.3. F.4.1 To correct the observed volume in gallons for any LP-Gas (the specific gravity and temperature of which is known) to gallons at 60°F (16°C), Table F.3.3 is used as follows: (a) Obtain the correction factor for the specific gravity and temperature as described in F.3.3.(b) Multiply the gallons observed by this correction factor to obtain the gallons at 60°F (16°C).
ExAmplE: A container has in it 4055 gal of LP-Gas with a specific gravity of 0.560 at a liquid temperature of 75°F. The correction factors in the 0.560 column are 0.980 at 76°F and 0.983 at 74°F, or, interpolating, 0.9815 for 75°F. The volume of liquid at 60°F is 4055 x 0.9815, or 3980 gal.
F.4.2 To determine the volume in gallons of a particular LP-Gas at temperature t to correspond with a given number of gallons at 60°F (16°C), Table F.3.3 is used as follows:(a) Obtain the correction factor for the LP-Gas, using the column for its specific gravity and reading the factor for temperature t.(b) Divide the number of gallons at 60°F (16°C) by thiscorrection factor to obtain the volume at temperature t.
* This section is an excerpt from the NFPA 58 Liquified Petroleum Gas Code — 2001 Edition
Table 5.4.1.3 Distances from Cylinders in Storage and exposures
![Page 221: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/221.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ap
pen
dic
es
LP Container Requirements
215
12SECTION
12
ExAmplE: It is desired to pump 800 gal (3.03 m3) at 60°F (15.5°C) into a container. The LP-Gas has a specific gravity of 0.510, and the liquid temperature is 44°F. The correction factor in the 0.510 column for 44°F is 1.025. Volume to be pumped at 44°F is 800/1.025 = 780 gal (2.95 m3).
F.5 maximum Liquid Volume Computations.
F.5.1 maximum Liquid LP-Gas Content of a Container at Any Given Temperature.F.5.1.1 The maximum liquid LP-Gas content of any container depends on the size of the container, whether it is installed above ground or under ground, the maximum permitted filling limit, and the temperature of the liquid [see Tables 4.4.2.2(a), (b), and (c).]F.5.1.2 The maximum volume fraction Vt (in percent of container capacity) of an LP-Gas at temperature t, having a specific gravity G and a filling limit and weight percent filling limit of L, is computed by use of the following formula:
or:
where:Vt = percent of container capacity that can be filled
with liquidL = maximum permitted filling limit by weight
(see Table 4.4.2.1)G = specific gravity of particular LP-GasF = correction factor to correct volume at
temperature t to 60°F (16°C)
ExAmplE: The maximum liquid content, in percent of container capacity, for an aboveground 30,000-gal (114-m3) water capacity container of LP-Gas having a specific gravity of 0.508 and at a liquid temperature of 80°F (27°C) is computed as follows:
From Table 4.4.2.1, L = 0.45, and from Table F.3.3, F = 0.967. Thus,
Liquified Petroleum Gas Code* (continued)
V80 =
F.5.2 Alternate method of Filling Containers.F.5.2.1 Containers equipped with fixed maximum level gauges or with variable liquid level gauges when temperature determinations are not practical can be filled with either gauge provided that the fixed maximum liquid level is installed or the variable gauge is set to indicate the volume equal to the maximum permitted filling limit as provided in 4.4.3.3(a). The level is computed on the basis of the liquid temperature being 40°F (4.4°C) for aboveground containers or 50°F (10°C) for underground containers.F.5.2.2 The percentage of container capacity that can be filled with liquid is computed by use of the formula shown in F.5.1.2, substituting the appropriate values as follows:
where: t = the liquid temperature [assumed to be 40°F (4.4°C) for aboveground containers or 50°F (10°C) for underground containers]. L = the loading limit obtained from Table 4.4.2.1 for: (a) The specific gravity of the LP-Gas to be contained. (b) The method of installation, aboveground or underground, and if aboveground, then: (1) For containers of 1200 gal (4.5 m3) water capacity or less. (2) For containers of more than 1200-gal (4.5-m3) water capacity. G = the specific gravity of the LP-Gas to be contained. F = the correction factor (obtained from Table F.3.3, using G and 40°F (4°C) for aboveground contain- ers or 50°F (10°C) for underground containers).
ExAmplE: The maximum volume of LP-Gas with a specific gravity of 0.508 that can be in a 1000-gal (3.8-m3) water capacity aboveground container that is filled by use of a fixed maximum liquid level gauge is computed as follows: t = is 40°F (4.4°C) for an aboveground container. L = for 0.508 specific gravity, and an aboveground
container of less than 1200-gal (4.5-m3) water capacity, from Table 4.4.2.1, is 42 percent.
G = is 0.508. F = for 0.508 specific gravity at 40°F (4.4°C) from
Table F.3.3 is 1.033.Thus,
* This section is an excerpt from the NFPA 58 Liquified Petroleum Gas Code — 2001 Edition
Vt = ÷ FL G
L G X F
Vt =
0.450.508 X 0.967
= 0.915 (91%) or 27,300 gal (103 m3)
L G X F
Vt =
0.450.508 X 1.033
= 0.800 (80%) or 8000 gal (3 m3)
V40 =
![Page 222: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/222.jpg)
216 victormfg.com
LP Container Requirements 12SECTION
Gas Equipment Catalog
Exception No. 1: Not applicable to installations in which overhanging structure is 50 ft. (15 m) or more above the relief valve discharge outlet.Exception No. 2: Where the distance from a 2001 to 30,000 gal. container to a building are in accordance with 3.11.2 and 3.11.4.
3.2.2.3 Where storage containers having an aggregate water capacity of more than 4000 gal (15.1 m3) are located in heavily populated or congested areas, the siting provisions of 3.2.2.2 and Table 3.2.2.2 shall be permitted to be modified as indicated by the fire safety analysis described in 3.10.2.2.3.2.2.4 Aboveground multicontainer installations comprised of containers having an individual water capacity of 12,000 gal (45 m3) or more and installed for use in a single location shall be limited to the number of containers in one group, with each group separated from the next group in accordance with the degree of fire protection provided in Table 3.2.2.4.Exception: Where the provisions of 3.11.3 and 3.11.4 are met the minimum separation distance between groups of ASME containers protected by hose stream only shall be one-half the distances in Table 3.2.2.4.
3.2.2.5 Underground or mounded containers shall be located outside of any buildings. Buildings shall not be constructed over any underground or mounded containers. Sides of adjacent containers shall be separated in accordance with Table 3.2.2.2 but shall not be separated less than 3 ft. (1 m).Where underground or mounded containers are installed parallel with ends in line, the number of containers in one group shall not be limited. Where more than one row is installed, the adjacent ends of the tanks in each row shall be separated by not less than 10 ft. (3 m).
* This section is an excerpt from the NFPA 58 Liquified Petroleum Gas Code — 2001 Edition
(f ) Where underground multicontainer installations are made of individual containers having a water capacity of 125 gal (0.5 m3) or more, such containers shall be installed so as to allow access at their ends or sides to facilitate working with cranes or hoists. (g) In applying the distance between buildings and ASME containers of 125-gal (0.5-m3) or more water capacity, a minimum of 50 percent of this horizontal distance shall also apply to all portions of the building that project more than 5 ft. (1.5 m) from the building wall and that are higher than the relief valve discharge outlet.This horizontal distance shall be measured from a point determined by projecting the outside edge of such overhanging structure vertically downward to grade or other level upon which the container is installed.
Table 3.2.2.2(d) Separation Distance Between Container Pressure Relief Valve and Building Openings
Water capacity per container
minimum distances
mounded or underground containersa
aboveground containersb
betWeen containersc
gal m3 ft m ft m ft m<125d <0.5d
10 3
0e 0e 0 0125-250 0.5 - 1.0 10 3 0 0251-500 1.0+ - 1.9 10 3 3 1501-2000 1.9+ - 7.6 25 7.6 3 1
2001-30,000 7.6+ - 114
50 15
50 15
1/4 of sum ofdiameters of
adjacent containers
30,001-70,000 114+ - 265 75 2370,001-90,000 265+ - 341 100 3090,001-120,000 341+ - 454 125 38120,001-200,000 454+ - 757 200 61
200,001-1,000,000 757+ - 3785 300 91>1,000,000 >3785 400 122
container type
exchange or filled
on site
distance horizontally from relief
valve discharge to opening
beloW discharge
discharge from relief valve,
vent discharge, and filling connection to exterior source of
ignition, openings into
direct-vent appliances, mechanical
ventilation air intakes
ft m ft mCylinder Exchange 3.0 0.9 5.0 1.5Cylinder Filled On Site 3.0 0.9 10.0 3.0ASME Filled On Site 5.0 1.5 10.0 3.0
Table 3.2.2.2 Separation Distances Between Containers, Important Buildings, and Other Properties*
aSee 3.2.2.2 Exception No. 2.bSee 3.2.2.2 (g).cSee 3.2.2.2 (f ).sSee 3.2.2.2 (a).eSee 3.2.2.2 (b), (c), and (d).
![Page 223: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/223.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ap
pen
dic
es
LP Container Requirements
217
12SECTION
12
Important Safety Information for the Dealer and Your Service and Installation PersonnelWhy is the fill so important?It is important that the first time a new propane tank is filled that it be filled to its maximum allowable liquid level with propane. This will help counteract the possible depletion of the odorant added to propane as a warning device in the event of a gas leak. Why? This puts the maximum amount of gas in the tank, which in turn puts the highest volume of ethyl mercaptan in the tank at a time when the odorant is most likely to be absorbed, absorbed or broken down by oxidation in the tank. If the odor produced by ethyl mercaptan is allowed to fade too much, its effectiveness as a warning device is diminished or may even be eliminated.The propane dealer should advise and warn the customer:• About the presence of the odorant in propane gas and
give the customer a scratch-and-sniff pamphlet to allow those using the propane gas to become familiar with the smell of the odorant.
• That the odorant can fade or become less intense. Competing odors and a person’s inability to smell can also mask or cover up propane odor.
• Gas detectors may provide an extra measure of safety.• They should not rely only upon the smell of propane for
detection of propane gas.Failure to properly advise the users of propane about its properties and those of ethyl mercaptan could lead to a severe fire or explosion hazard, resulting in death or bodily injury.
Why is putting methanol in a tank so important? Freeze-ups!!!
An LP-gas regulator can double for a fairly effective small refrigerator. This is because the high-pressure gas, coming into the regulator, expands as it goes through the orifice. This expansion of gas creates refrigeration. Therefore, if there is moisture in the gas, small droplets may freeze as they are attempting to pass through the cold orifice. If the flow of gas is large enough and there is enough moisture in the fuel, the orifice of the regulator could well be blocked by ice, stopping the flow of gas. Freeze-ups can occur even though outside temperatures are above freezing.How does moisture get in the tank? ASME tanks are hydrostatically tested during fabrication, thereby introducing moisture to the tank. Vacuum pre-purging of tanks should eliminate most of this moisture and air containing moisture from the tank. That is why it is important that air (which will contain moisture) not be allowed into the tank when the vacuum is neutralized when first filling a vacuum pre-purged tank.The easiest way to cure this type of freeze-up is to keep as much moisture as possible from your fuel. Adding genuine absolute anhydrous methanol (99.85 pure) to your tanks when you first fill them is extra insurance to prevent freeze-ups from any moisture that may still be in the new tank. Methanol will lower the freezing point of water sufficiently to prevent freezing. When mounting the regulator, be sure the regulator outlet is higher than the service valve outlet.
If pigtails are “looped,” be sure the loop is upward, preventing moisture from collecting and freezing at the bottom of the loop. Many times regulators are blamed for freeze-ups when ice frozen in the pigtails is the cause. Use larger pigtails (3/8” OD hogtails have more than three times the cross-sectional area of the standard 1/4” pigtail). Two-stage regulation helps prevent freeze-ups.
Warning and notice about the proper installation of propane tanks designed for use underground.
When a tank is designed for use in the underground storage of propane gas, a licensed propane dealer or installer must install it. The party installing the tank must inspect the tank and ensure that at the time of installation the external coating applied to the tank by the manufacturer remains continuous and intact. Failure to install the propane tank with an intact and continuous external coating voids all warranties (but not disclaimers) of the manufacturer. It is the responsibility of the purchaser or installer 1) determine whether additional protection should be used and 2) determine mat the additional protection is compatible with the coating applied by the manufacturer. To help ensure long-term protection of the underground tank, cathodic protection; should be used and may be required by governing authorities having jurisdiction over the installation of underground propane tanks at the installation site. This tank is sold subject to and limited by the terms and conditions of sale, including, but not limited to, the manufacturer’s warranty. Periodic inspections of tanks installed underground are recommended and may be required by the jurisdiction where installed.The container and valves of propane tanks to be buried underground should also be carefully checked for leaks immediately prior to installation in the ground.The licensed propane dealer or installer should make sure they follow all applicable federal, state or local regulatory requirements for protective coatings when they install a propane tank underground. The purchaser and installer are responsible for compliance with such federal, state and local regulations.
![Page 224: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/224.jpg)
218 victormfg.com
LP Container Requirements 12SECTION
Gas Equipment Catalog
Purging LP-Gas ContainersUp to 2,000 Water Gallon Capacity — ASME & DOT Containers, Including Motor Fuel Containers.Purging and moisture RemovalAll new containers (and in some cases used containers) may contain water, air, or other contaminants, and it is essential that these be removed before filling the container and placing it into service. Water vapor present in the gas vapor may cause regulator freeze-up at the inlet orifice and interrupt the gas service. Also, it may have an effect on the ability of the odorant to meet the present standards, as water can cause oxidation (rusting) on the inside of the container and result in “odorant fade.” Air in the container will cause abnormally high pressure, with the result that the pressure relief valve may open. Air in the system is also likely to cause pilot flames to go out and result in a service call. Additionally, air in the container carries moisture, which can cause service problems. If a container is suspected of being depressurized or open to the atmosphere for a period of time, it must be re-purged as if it were a new container.To purge a container, the following steps should be taken:1. Purging of containers should be performed in an
approved area (see NFPA #58).2. Determine if the container pressure is zero. Should
the container contain only air pressure, the air may be vented directly to the atmosphere through the service valve.
3. If free water is present in the container, it should be drained.
4. Pressurize the container to approximately 15 PSIG with LP-gas vapor. Never purge with liquid LP-gas; to do so will cause the moisture vapor to chill and remain in the container.
5. Fully open the container service valve and vent to a safe atmosphere.
6. Repeat fourth and fifth steps for a total of five purgings.7. The usual five purge pressurization methods requires
the venting of about 15-18 gallons of LP-gas per 1,000 gallons of container capacity.
8. Add the suggested amount of methanol (see chart on the next column) and close valve. Methanol must be used in an approved and safe manner. Refer to the methanol MSDS for proper handling and warnings.
9. Repressurize the container with odorized LP-gas vapor to 15 PSIG.
10. The container is now ready to be filled with LP-gas.11. Once filled, all fittings and tank openings should be
checked for leaks using an approved leak detecting solution.
12. The container is now ready to be placed in service.
methanol Injection Chart – Suggested Amounts
1 pint of methanol per 100 gallons of container capacity100# I.C.C. or D.0.T. cylinder add 1/8 pint or 2 fluid ounces 100 gallon container add 1 pint 250 gallon container add 2.5 pints 500 gallon container add 5 pints 1,000 gallon container add 10 pints 2,000 gallon container add 20 pints
Alternate Purge Method Utilizing a CompressorAn LP-Gas compressor can be used to evacuate air in a container to about 26” of mercury vacuum (2 PSI absolute pressure) when discharging to atmosphere. Hose suitable for vacuum service would be used and all unused valves must be closed. Protective caps on both liquid fill and vapor equalization valves must be screwed on tightly to prevent air from entering the container when vacuum is applied. When pressure has been reduced to 26” of mercury vacuum LP gas vapor can be introduced until the container has reached atmospheric pressure. Add methanol as suggested and the container is then ready to be filled with liquid LP-gas.This method effectively removes water vapor after the water is drained and reduces air in the container to about 10 of the volume at atmospheric pressure. No LP-gas is released to he atmosphere with this process. Evacuation time with the 36 CFM compressor is approximately 15 minutes per 1,000 gallons of tank capacity. A CFM comporssor would take approximately 30 minutes per 1,000 gallons of tank capacity.
AddendumA. See NFPA-58 for more information on purging.B. Consult Material Safety Data Sheet (MSDS - Methanol)
for additional information on care and handling of methanol.
C. Consult NPGA Safety Bulletin on “Static Electricity”
![Page 225: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/225.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ap
pen
dic
es
LP Container Requirements
219
12SECTION
12
What is Corrosion?Corrosion of a steel tank is an electrical and chemical deterioration of the metal. It is sometimes called “electrolysis”. It causes pits which lead to holes on one place and not another.
What is Cathodic Protection?Cathodic protection is a procedure used to protect an object from corrosion by making it a cathode. To make a tank a cathode, you have to attach an anode to it. Both have to be in an electrolyte such as earth or water. To protect a propane tank, you would attach at least one anode consisting of a bar of magnesium metal packed inside a cloth bag containing conductive earth backfill with a wire that is attached to the magnesium and the tank. Usually, 17 lbs. of magnesium and 28 Ibs. of earth backfill are used. The magnesium is a source of electrons for the iron atoms and it is from where d.c. current originates. As long as enough electrons flow from the magnesium through the wire and the connections on the tank, the tank will not corrode.
Why you Should Use Cathodic Protection When Installing an Underground Propane TankFirst, what makes soil corrosive? Soil contains water and dissolved minerals responsible for damaging underground tanks. If you answer any of the following questions yes, then the tank will be corroded by the soil. Will it ever rain or snow there? Will the property owner plant grass, flowers, shrubs or trees over or near the tank? Will the grass, flowers, shrubs or trees be fertilized? Will ground moisture condense on the outside of the tank? Will water condense out of thin air on the surface of a cold container? Will the tank be near a sidewalk or down gradient from a driveway? Will the property owner ever throw salt or calcium chloride on the pavement to melt snow and ice? Will the tank ever be located near or downhill from livestock where salt and urea from animal waste will leach into the earth? Does the irrigation water contain salt or alkali salts? If a tank is set in a hole blasted from solid rock, does the rock contain pyrites, graphite or acidic rock that will be fractured and exposed to the oxidizing effect of air and water? If the tank is backfilled with sand or gravel from a sand or gravel company, will the sand contain minerals mined from river deposits not representative of the site in which the tank is to be buried? Will the tank be downhill from a septic tank leach field? Will the soil contain gypsum? Will the tank be set in shale or clay? Will groundwater be present? Will the tank be set on undisturbed earth and backfilled with loose backfill?Second, let’s consider coatings, the traditional way of preparing underground propane tanks for installation. All steel objects are painted to keep them from rusting. The paint is a waterproof barrier between the steel surface and moisture in the air. Similarly, underground tanks need a waterproof coating to protect them from corrosive groundwater. Ordinary paint coatings do not
hold up under constant contact with mineralized moisture in the earth. Therefore, specialized coatings are needed to withstand the corrosive environment underground and provide a barrier between the steel surface and air, water and even electricity without deteriorating over time. The first line of defense against corrosion on an underground tank is good coating. Paint and coating companies make a variety of coatings for a vast array of applications. It is important to apply those that will hold up over time to constant attack by water, oxygen, carbon dioxide, mild acids, mechanical abrasion from rocks, earth movements, roots, bacteria and other biological organisms as they feed on organic compounds in them. They must be applied correctly or they will not adhere to the steel surface. Quality Steel applies a tough chemical and water resistant coating at the factory — a hard, baked on polyurethane finish. This factory applied coating is designed to be the final coating for the tank prior to its burial in the ground, provided the tank has an intact and continuous external coating at the time of burial. It is the installer’s responsibility to thoroughly inspect the tank to determine whether the factory applied protective coating is intact and continuous. If the coating is not found to be intact and continuous, then additional protection that is compatible with the manufacturer’s coating must be applied in a way to obtain this important result prior to burial. Coatings alone may not protect a buried tank against corrosion. After inspection and touchup the tanks can still get scratched, scraped and gouged during handling, setting, backfilling and settling. As a result the coating can have small imperfections here and there. Corrosion pitting rates are greater at these flaws, scratches and gaps in the coating than they are on completely bare tanks. Therefore, cathodic protection with anodes is needed to protect the steel wherever it is exposed.So, what can you do to provide cathodic protection for the underground propane tank? Anodes of magnesium are used to make the propane tank a cathode, thus improving its protection against possible corrosion. Magnesium anodes come in all shapes and sizes. The magnesium in a packaged anode can weigh from 1 to 50 Ibs. The most commonly used anode in the United States is a 17 Ib. anode. With 28 Ibs. of powdered backfill packed around the magnesium, a packaged 17 lbs.anode weighs about 45 Ibs.
Why You Should Use Cathodic Protection When Installing an Underground Propane Tank
![Page 226: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/226.jpg)
220 victormfg.com
LP Container Requirements 12SECTION
Gas Equipment Catalog
Tests on underground propane tanks have shown that smaller anodes can be effective at controlling corrosion on a well coated tank. Small anodes are used when the surface area or object to be protected is small. They cost less but cost the same as a large anode to install. However, it is important to remember that the life of a small anode is shorter than for a larger one. One of the more common questions asked is, “How long will an anode last?” Design engineers prefer to use larger anodes (and in greater numbers) because they last longer. The conditions and environment in which tanks and anodes are buried are so varied (as well as change with time) so that there is no definitive answer. Finally, however, when an anode is 85 consumed, it becomes too small to be effective. Because soil conditions change with time, one can hope for the best but plan for the worst.How do you install the anode? This is a very important question, for if the anode is not properly installed, it will not work. Schmoldt recommends the following: Install one 17 Ib. magnesium anode on a 500 gal. tank and two on a 1,000 gal. tank. The reason for the latter is to ensure that enough cathodic protection current is available for many years. Bury the anode at the end of the excavation where the earth is the wettest and the most conductive to the anode current. If water is available, pour 5 gal. on the anode to “jump start” the flow of current. Otherwise, the dry backfill will have to absorb moisture from the soil before current will flow. Roll out the anode wire to either the flat plate fitting on top of the tank or to the lifting ear. Wrap the wire around the fitting or ear so that the connection can not be pulled off should someone trip on the wire. Leave slack in the wire so that it is not pulled apart when the excavation is backfilled.
The wire can be attached to the tank by a thermite weld or with a nut and bolt. Whether you use a thermite weld or nut and bolt, remove 1” insulation on the copper wire and file off any paint or coating at the connection so that the metal wire is making contact to the tank for the weld or connection. If you use a thermite weld, the weld will not ignite the propane in the tank, but it could ignite propane in sufficient concentration in the excavation around the tank. Propane is heavier than air and will collect at your feet. If you smell propane, do not make the connection with the weld.So, how do you know a tank is protected? It doesn’t take long to check, and a check should be made at least annually. If the voltage of steel is -0.85 volts or greater, it is protected. It takes a voltmeter and a copper sulfate electrode to take the reading. It can be taken by your service person with a basic understanding of cathodic protection. If the reading is >-0.85 volts, you can assume that the tank is protected at the location where the reading was taken on the date it was taken. If the reading is <-0.85 volts, the anode installed on the tank either has been consumed, or the tank is connected to the house utilities without dielectric union, or the wire has been disconnected. Occasionally, there is a problem with the testing equipment or contact to the tank. The voltmeter’s contact with the tank can be made on any metal connected to the tank, including the gauging device, the regulator, the pressure relief valve or other fittings. The dome is not a good contact point. It is recommended that you take at least four readings around the tank.
Why You Should Use Cathodic Protection When Installing an Underground Propane Tank (continued)
Victor/F.w. Webb
stocks burnham boilers.
![Page 227: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/227.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ap
pen
dic
es
LP Container Requirements
221
12SECTION
12
Central ACCompressor
(source of ignition) Cylinders notfilled on site
Cylinders notfilled on site
from bulk truck
Crawl space opening,windows, or exhaust fan
Intake to direct-
vent appliance
5 ft. (min)(Note 1)
3 ft. (min)(Note 3)
3 ft. (min)(Note 3)
5 ft. (min)(Note 1)
Windows airconditioner(source ofignition)
10 ft. (min)(Note 2)
10 ft. (min)(Note 1)
Intake to direct-vent appliance
10 ft. (min)(Note 1)
10 ft. (min)(Note 1)
10 ft. (min)(Note 1)
Window air conditioner (source of ignition)
10 ft. (min)(Note 1)
5 ft. (min)(Note 2)
Under 125gal. w.c.
25 ft. (min)(Note 3)
25 ft. (min)(Note 3)
Central AC Compressor(source of ignition)
501-2000 gal w.c.
125-500 gal w.c.
Under 125gal w.c.
CylindersFigure I.1 (a)*
Aboveground ASME Containers Figure I.1 (b)*
For SI units, 1 ft. = 0.3048 m
Note 1: 5 ft. minimum front relief valve in any direction away from any exterior sources of ignition, openings into direct-vent appliances, or mechanical ventilation air intakes. Refer to 6.3.7(2).
Note 2: If the cylinder is filled on site from a bulk truck, the filling connection and vent valve must be at least 10 ft. from any exterior source of ignition, openings into direct-vent appliances, ore mechanical ventilation air intakes. Refer to 6.3.10.
Note 3: Refer to 6.3.7(1).
Note 1: Regardless of its size, any ASME container filled on site must be located so that the filling connection and fixed maximum liquid level gauge are at least 10 ft. from any external source of ignition (e.g., open flame, window AC, compressor), intake to direct-vented gas appliance, or intake to a mechanical ventilation system. Refer to 6.3.10.
Note 2: Refer to 6.3.9.
Note 3: This distance can be reduced to no less than 10 ft. for a single container of 1,200 gal. (4.5 m3) water capacity or less, provided such container is at least 25 ft. from any other LP-Gas container of more than 125 gal. (0.5 m3) water capacity. Refer to 6.3.3. * Figures are for illustrative purposes only; code shall govern.
![Page 228: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/228.jpg)
222 victormfg.com
LP Container Requirements 12SECTION
Gas Equipment Catalog
Window air
conditioner
(source of ignition
Intake to direct-vent appliance
10 ft. (min)(Note 1)
10 ft. (min)(Note 1)
10 ft. (min)(Note 1)
10 ft. (min)(Note 2)
10 ft. (min)(Note 2) Crawl space opening,
window, or exhaust fan
2000 gal w.c.or less
Central AC Compressor(source of ignition)
Underground ASME Containers Figure I.1 (c)*
For SI units, 1 ft. = 0.3048 m
Note 1: The relief valve, filling connection, and fixed maximum liquid level gauge vent connection at the container must be at least 10 ft. from any exterior source of ignition, openings into direct-vent appliances, or mechanical ventilation air intakes. Refer to 6.3.10.
Note 2: No part of an underground container can be less than 10 ft. from an important building or line of adjoining property that can be built upon. Refer to 6.3.4.2.
* Figures are for illustrative purposes only; code shall govern.
Victor/F.w. Webb stocks both lyco mechanical fittings and continential stab
fittings for underground pe gas pipe.
![Page 229: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/229.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ap
pen
dic
es
Orifice Sizing and Properties of LP Gases
223
12SECTION
12
Approximate Properties LP-Gases* commercial propane
vapor pressure in psi (absolute pressure at) 70°F 145 100°F 218 105°F 233 130°F 315
Specific Gravity Of Liquid At 60°F 0.504initial boiling point at 14.7 psia, °F –44 Weight Per Gallon Of Liquid At 60°F, lb. 4.20 Specific Heat Of Liquid, btu/lb. At 60°F .630 Cubic Feet Of Vapor Per Gallon At 60°F 36.38 Cubic Feet Of Vapor Per Pound At 60°F 8.66 Specific Gravity of Vapor (Air = 1) At 60°F 1.50 ignition temperature In Air, °F 920 – 1,120 maximum flame temperature In Air, °F 3,595
Limits Of Flammability In Air Percent Of Vapor In Air–Gas Mixture: Lower 2.15 Upper 9.60
Latent Heat Of Vaporization At Boiling Point btu Per Pound 184 btu Per Gallon 773
Total Heating Values After Vaporization btu Per Cubic Foot 2,488 btu Per Pound 21,548 btu Per Gallon 91,502
Table F.2 LP-Gases* (Btu per hour at sea level) propane ButaneBtu per cubic foot = 2488 3280Specific gravity = 1.50 2.01Pressure at orifice, inches water column = 11 11Orifice coefficient = 0.9 0.9For altitudes above 2000 ft. first select the equivalent orifice size at sea level from Table F.4.
Orifice or drill Size Propane00.008 51900.009 65600.010 81200.011 98100.012 116980.000 148079.000 170878.000 208077.000 262976.000 324975.000 358174.000 411973.000 467872.000 508171.000 549570.000 637569.000 693468.000 781367.000 832066.000 884865.000 995564.000 1053563.000 1112562.000 1173561.000 1236760.000 1300859.000 1366058.000 1433357.000 1502656.000 1757255.000 2193954.000 2463053.000 2876952.000 32805
Orifice or drill Size Propane51.000 3653150.000 3984249.000 4336148.000 4698347.000 5008846.000 5329645.000 5464144.000 6022943.000 6436942.000 7109541.000 7492440.000 7802939.000 8051338.000 8372137.000 8786036.000 9220735.000 9831234.000 10017533.000 10379732.000 10938531.000 11704330.000 13411929.000 15036628.000 16030127.000 16858026.000 17561725.000 18161924.000 18782823.000 19279622.000 20035021.000 20552520.000 21069919.000 22394518.000 233466
Specific Gravity Specific Multiplier Gravity Multiplier 0.45 1.155 0.95 0.795 0.50 1.095 1.00 0.775 0.55 1.045 1.05 0.756 0.60 1.000 1.10 0.739 0.65 0.961 1.15 0.722 0.70 0.926 1.20 0.707 0.75 0.894 1.25 0.693 0.80 0.866 1.30 0.679 0.85 0.840 1.35 0.667 0.90 0.817 1.40 0.655
* This section is an excerpt from the NFPA 54 National Fuel Gas Code — 1999 Edition
* This section is an excerpt from the NFPA 58 Liquified Petroleum Gas Code — 2001 Edition
Table F.2 LP-Gases (Btu per hour at sea level)
Table F.3 Multipliers for Utility Gases of Another Specific Gravity*
![Page 230: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/230.jpg)
224 victormfg.com
Orifice Sizing and Properties of LP Gases 12SECTION
Gas Equipment Catalog
Table F.1 Utility Gases*(or Natural Gas Specific Gravity .60) (cubic feet per hour at sea level)
Orifice Pressure at Orifice 3/4 inches Water column or drill Size 3.5 4 7 80 0.52 0.55 0.73 79 0.59 0.64 0.84 78 0.76 0.78 1.04 77 0.95 0.99 1.31 76 1.13 1.21 1.61
75 1.25 1.34 1.79 74 1.44 1.55 2.05 73 1.63 1.76 2.32 72 1.77 1.90 2.52 71 1.97 2.06 2.73
70 2.22 2.39 3.16 69 2.43 2.61 3.47 68 2.72 2.93 3.88 67 2.91 3.12 4.13 66 3.09 3.32 4.39
65 3.39 3.72 4.84 64 3.68 4.14 5.23 63 3.92 4.19 5.55 62 4.08 4.39 5.81 61 4.34 4.66 6.15
60 4.55 4.89 6.47 59 4.76 5.11 6.78 58 5.03 5.39 7.13 57 5.23 5.63 7.44 56 6.13 6.58 8.73
55 7.68 8.22 10.85 54 8.59 9.23 12.25 53 10.04 10.80 14.29 52 11.46 12.31 16.34 51 12.77 13.69 18.16
50 13.92 14.94 19.77 49 15.20 16.28 21.60 48 16.36 17.62 23.31 47 17.52 18.80 24.93 46 18.57 19.98 26.43
45 19.15 20.52 27.18 44 21.01 22.57 29.87 43 22.39 24.18 32.02 42 24.95 26.50 35.24 41 25.98 28.15 37.17
40 27.03 29.23 38.79 39 28.20 30.20 39.97 38 29.25 31.38 41.58 37 30.63 32.99 43.62 36 32.14 34.59 45.77
Orifice Pressure at Orifice 3/4 inches Water column or drill Size 3.5 4 7 35 34.95 36.86 48.78 34 35.05 37.50 49.75 33 36.08 38.79 51.46 32 38.30 40.94 54.26 31 40.85 43.83 58.01
30 46.87 50.39 66.72 29 52.33 56.19 74.45 28 55.92 59.50 79.50 27 58.83 63.17 83.59 26 61.27 65.86 87.24
25 63.58 68.22 90.36 24 65.67 70.58 93.47 23 67.07 72.20 94.55 22 70.08 75.21 99.60 21 71.83 77.14 102.29
20 73.68 79.08 104.75 19 77.98 83.69 110.67 18 81.57 87.56 116.03 17 84.82 91.10 120.33 16 88.77 95.40 126.78
15 92.02 98.84 131.07 14 94.40 100.78 133.22 13 97.11 104.32 138.60 12 101.41 108.52 143.97 11 103.62 111.31 147.20
10 106.16 114.21 151.50 9 109.07 117.11 154.71 8 112.20 120.65 160.08 7 114.40 123.01 163.31 6 117.88 126.78 167.51 5 119.97 128.93 170.82 4 123.93 133.22 176.18 3 128.79 137.52 182.64 2 138.76 148.61 197.66 1 147.26 158.25 209.48
For SI units, 1 Btu/hr = 0.293 W; 1 ft3 = 0.028 m3; 1 ft = 0.305 m; 1 in. water column = 249 pa. Notes: 1. Specific Gravity = 0.60; orifice coefficient = 0.90.2. For utility gases of another specific gravity, select multiplier from Table F.3. For altitudes above 2000 ft, first select the equivalent orifice size at sea level from Table F.4.
* This section is an excerpt from the NFPA 58 Liquified Petroleum Gas Code — 2001 Edition
![Page 231: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/231.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ap
pen
dic
es
Liquid Volume Tables and Temperature Correction Factors
225
12SECTION
12
This appendix is not a part of the requirements of this NFPA document but is included for informational purposes only.
F.1 Scope. F.1.1 Application. This appendix explains the basis for Table 4.4.2.1, includes the LP-Gas liquid volume temperature correction table, Table F.3.3, and describes its use. It also explains the methods of making liquid volume computations to determine the maximum permissible LP-Gas content of containers in accordance with Tables 4.4.2.2(a), (b), and (c).
F.2 Basis for Determination of LP-Gas Container Capacity. The basis for determination of the maximum permitted filling limits shown in Table 4.4.2.1 is the maximum safe quantity that will assure that the container will not become liquid full when the liquid is at the highest anticipated temperature.F.2.1 For portable containers built to DOT specifications and other aboveground containers with water capacities of 1200 gal (4.5 m3) or less, this temperature is assumed to be 130°F (54°C). F.2.2 For other aboveground uninsulated containers with water capacities in excess of 1200 gal (4.5 m3), including those built to DOT portable or cargo tank specifications, this temperature is assumed to be 115°F (46°C).F.2.3 For all containers installed under ground, this temperature is assumed to be 105°F (41°C).
F.3 Liquid Volume Correction Table. Correction of observed volume to standard temperature condition (60°F and equilibrium pressure).F.3.1 The volume of a given quantity of LP-Gas liquid in a container is directly related to its temperature, expanding as temperature increases and contracting as temperature decreases. Standard conditions, often used for weights and measures purposes and, in some cases, to comply with safety regulations, specify correction of the observed volume to what it would be at 60°F (16°C).F.3.2 To correct the observed volume to 60°F (16°C), the specific gravity of LP-Gas at 60°F (16°C) in relation to water at 60°F (16°C) (usually referred to as “60°/60°F”) and its average temperature must be known. The specific gravity normally appears on the shipping papers. The average liquid temperature can be obtained as follows:(1) Insert a thermometer in a thermometer well in the
container into which the liquid has been transferred, and read the temperature after the completion of the transfer. [see F.3.2(c) for proper use of a thermometer].
(2) If the container is not equipped with a well, but is essentially empty of liquid prior to loading, the temperature of the liquid in the container from which liquid is being withdrawn can be used. Otherwise, a thermometer can be inserted in a thermometer well or other temperature-sensing device installed in the loading line at a point close to the container being loaded. Read temperatures at intervals during trans- fer and averaging. [See F.3.2(c).]
(3) A suitable liquid should be used in thermometer wells to obtain an efficient heat transfer from the LP- Gas liquid in the container to the thermometer bulb. The liquid used should be noncorrosive and should not freeze at the tem-peratures to which it will be subjected. Water should not be used.
F.3.3 The volume observed or measured is corrected to 60....F (16....C) by use of Table F.3.3. The column headings, across the top of the tabulation, list the range of specific gravities for the LP-Gases. Specific gravities are shown from 0.500 to 0.590 by 0.010 increments, except that special columns are inserted for chemically pure propane, isobutane, and normal butane. To obtain a correction factor, follow down the column for the specific gravity of the particular LP-Gas to the factor corresponding with the liquid temperature. Interpolation between the specific gravities and temperatures shown can be used if necessary.
* This section is an excerpt from the NFPA 58 Liquified Petroleum Gas Code — 2001 Edition
Appendix F Liquid Volume Tables, Computations and Graphs
![Page 232: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/232.jpg)
226 victormfg.com
Liquid Volume Tables and Temperature Correction Factors 12SECTION
Gas Equipment Catalog
Liquid Volume Correction Factors*Specific Gravities at 60°F/60°F
OBSeRVeD TemP., DeGReeS PROPANe FAHReNHeIT 0.5079 48 1.019 50 1.016 52 1.013 54 1.010 56 1.007 58 1.003 60 1.000 62 0.997 64 0.993 66 0.990 68 0.986 70 0.983 72 0.980 74 0.976 76 0.973 78 0.970 80 0.967 82 0.963
OBSeRVeD TemP., DeGReeS PROPANe FAHReNHeIT 0.5079 –50 1.155 –45 1.148 –40 1.142 –35 1.135 –30 1.129 –25 1.122 –20 1.115 –15 1.109 –10 1.102 –5 1.094 0 1.088 2 1.086 4 1.083 6 1.080 8 1.078 10 1.075 12 1.072 14 1.070
OBSeRVeD TemP., DeGReeS PROPANe FAHReNHeIT 0.5079 16 1.067 18 1.065 20 1.062 22 1.059 24 1.056 26 1.053 28 1.050 30 1.047 32 1.044 34 1.041 36 1.038 38 1.035 40 1.032 42 1.029 44 1.026 42 1.029 44 1.026 46 1.022
OBSeRVeD TemP., DeGReeS PROPANe FAHReNHeIT 0.5079 84 0.959 86 0.956 88 0.952 90 0.949 92 0.945 94 0.941 96 0.938 98 0.934 100 0.930 105 0.920 110 0.911 115 0.902 120 0.892 125 0.881 130 0.871 135 0.861 140 0.850
* This section is an excerpt from the NFPA 58 Liquified Petroleum Gas Code — 2001 Edition
![Page 233: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/233.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ap
pen
dic
es
Vaporizer and Electrical Requirements
227
12SECTION
12
Table 3.6.3.5 minimum Separation Distances Between Direct-Fired Vaporizers and Exposures
mINImUm DISTANCe ReQUIReDexPOSURe FT mContainer 10 3.0Container Shutoff Valves 15 4.6Point Of Transfer 15 4.6Nearest Important Buildings Or Group Of 25 7.6 Buildings Or Line Of Adjoining Property That Can Be Built Nearest Chapter 7 Building Or Room 10 3.0 Housing Gas–Air Mixer Cabinet Housing Gas–Air Mixer Outdoors 0 0Note: Do not apply distances to the building in which a direct-fired vaporizer is installed.
3.6.6. Installation of Waterbath Vaporizers. Waterbath vaporizers shall comply with 2.5.5.3 and shall be installed as follows:3.6.6.1 If a waterbath vaporizer is electrically heated and all electrical equipment is suitable for Class 1, Group D locations, the unit shall be treated as indirect-fired and shall be installed in accordance with 3.6.2.3.6.6.2 All other waterbath vaporizers shall be treated as direct-fired vaporizers and shall be installed in accordance with 3.6.3.3.6.7 Installation of Electric Vaporizers. Electric vaporizers, whether direct immersion or indirect immersion, shall be treated as indirect-fired and shall be installed in accordance with 3.6.2.
* This section is an excerpt from the NFPA 58 Liquified Petroleum Gas Code — 2001 Edition
3.6.3.1 Direct-fired vaporizers shall comply with 2.5.5.2 and shall be installed as follows.3.6.3.2 Where a direct-fired vaporizer is installed in a separate structure, the separate structure shall be constructed in accordance with Chapter 7.3.6.3.3 The housing for direct-fired vaporizers shall not have any drains to a sewer or a sump pit that is shared with any other structure or to a sewer. Pressure relief valve discharges on direct-fired vaporizers shall be piped to a point outside the structure or building.3.6.3.4 Direct-fired vaporizers shall be connected to the liquid space or to the liquid or vapor space of the container. A manually operated shutoff valve shall be installed in each connection of the container supplying the vaporizer.3.6.3.5 Direct-fired vaporizers of any capacity shall be located in accordance with Table 3.6.3.5.
3.6.3 Installation of Direct-Fired Vaporizers
3.7.2 Electrical Equipment3.7.2.1 Electrical equipment and wiring shall be of a type specified by, and installed in accordance with, NFPA 70, National Electrical Code®, for ordinary locations.Exception: Fixed electrical equipment in classified areas shall comply with 3.7.2.2.3.7.2.2* Fixed electrical equipment and wiring installed within classified areas specified in Table 3.7.2.2 shall comply with Table 3.7.2.2 and shall be installed in accordance with NFPA 70, National Electrical Code. The provision shall apply to vehicle fuel operations. (See Figure 3.7.2.2.)Exception: This provision shall not apply to fixed electrical equipment at residential or commercial installations of LP-Gas systems or to systems covered by Section 3.8.
FIGURe 3.7.2.2 extent of electrically classified area. (See Table 3.7.2.2.)3.7.2.3 Fired vaporizers, calorimeters with open flames, and other areas where open flames are present either intermittently or constantly shall not be considered electrically classified areas.
![Page 234: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/234.jpg)
228 victormfg.com
Suggested method of Leak Checking 12SECTION
Gas Equipment Catalog
D. Suggested Method for Checking for Leakage*
In case careful observation of the test hand for a sufficient length of time reveals no movement, the piping should be purged and a small gas burner turned on and lighted, and the hand of the test dial again observed. If the dial hand moves (as it should), it will show that the meter is operating properly. If the test hand does not move or register flow of gas through the meter to the small burner, the meter is defective and the gas should be shut off and the serving gas supplier notified.
D.3 Testing for Leakage Not Using a meter. This test can be done by one of the following methods:
(a) For Any Gas System. To an appropriate checkpoint, attach a manometer or pressure gauge between the inlet to the piping system and the first regulator in the piping system, and momentarily turn on the gas supply and observe the gauging device for pressure drop with the gas supply shut off. No discernible drop in pressure should occur during a period of 3 minutes.(b) For Gas Systems Using Undiluted Liquefied Petroleum Gas. System Preparation for Propane. A leak check performed on an LP-Gas system being placed back in service should include all regulators, including
appliance regulators, and control valves in the system. Accordingly, each individual equipment shutoff valve should be supplying pressure to its appliance for the leak check. This check will prove the integrity of the 100 percent pilot shutoff of each gas valve so equipped, so the manual gas cock of each gas valve incorporating a 100 percent pilot shutoff should be in the on position. Pilots not incorporating a 100 percent pilot shutoff valve and all manual gas valves not incorporating safety shutoff systems are to be placed in the off position prior to leak checking, by using one of the following methods:(1) By inserting a pressure gauge between the container gas shutoff valve and the first regu- lator in the system, admitting full container pressure to the system and then closing the container shutoff valve. Enough gas should then be released from the system to lower the pressure gauge reading by 10 psi (69 kPa). The system should then be allowed to stand for 3 minutes without showing an increase or a decrease in the pressure gauge reading.(2) For systems serving appliances that receive gas at pressures of 1/2 psi (3.5 kPa) or less, by inserting a water manometer or pressure gauge into the system downstream of the final system regulator, pressurizing the system with either fuel gas or air to a test pressure of 9 in. ± 1/2 in. (2.2 kPa ± 0.1 kPa) water col- umn, and observing the device for a pressure change. If fuel gas is used as a pressure source, it is necessary to pressurize the sys- tem to full operating pressure, close the con- tainer service valve, and then release enough gas from the system through a range burner valve or other suitable means to drop the sys- tem pressure to 9 in. ± 1/2 in. (2.2 kPa ± 0.1 kPa) water column. This ensures that all regu- lators in the system are unlocked and that a leak anywhere in the system is communicated to the gauging device. The gauging device should indicate no loss or gain of pressure for a period of 3 minutes.
This appendix is not a part of the requirements of this code but is included for informational purposes only.D.1 Use of Lights. Artificial illumination used in connection with a search for gas leakage should be restricted to battery-operated flashlights (preferably of the safety type) or approved safety lamps. In searching for leaks, electric switches should not be operated. If electric lights are already turned on, they should not be turned off.D.2 Testing for Leakage Using the Gas meter. Immediately prior to the test, it should be determined that the meter is in operating condition and has not been bypassed. Checking for leakage can be done by carefully watching the test dial of the meter to determine whether gas is passing through the meter. To assist in observing any movement of the test hand, wet a small piece of paper and paste its edge directly over the centerline of the hand as soon as the gas is turned on. This observation should be made with the test hand on the upstroke. Table D.2 can be used for determining the length of observation time.
Table D.2 Test Observation Times for Various meter Dials
DIAL STyLeS (FT3) TeST TIme (mINUTeS) 1/4 5 1/2 5 1 7 2 10 5 20 10 30
For SI units, 1 ft3 = 0.028 m3.
![Page 235: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/235.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ap
pen
dic
es
Suggested method of Leak Checking
229
12SECTION
12
D. Suggested Method for Checking for Leakage (continued)
3.2.15.3 Metallic pipe joints shall be permitted to be threaded, flanged, welded, or brazed using pipe and fittings that comply with 2.4.2 and 2.4.4 as follows.
(a) Metallic threaded and welded pipe joints shall be in accordance with Table 3.2.15.3(a).
Table 3.2.15.3(a) Types of metallic Pipe Joints in LP-Gas ServiceSeRVICe SCHeDULe 40 SCHeDULe 80Liquid Welded Threaded or Welded Vapor, £125 psig Threaded or Threaded or (£0.9 MPag) Welded Welded Vapor, >125 psig Welded Threaded or (>0.9 MPag) Welded
(b) Fittings and flanges shall be designed for a working pressure equal to or greater than the required working pressure of the service for which they are used.
(c) Brazed joints shall be made with a brazing material having a melting point exceeding 1000°F (538°C).
(d) Gaskets used to retain LP-Gas in flanged connections in piping shall be resistant to the action of LP-Gas. They shall be made of metal or material confined in metal having a melting point over 1500°F (816°C) or shall be protected against fire exposure. When a flange is opened, the gasket shall be replaced.Exception No. 1: Aluminum O-rings and spiral wound metal gaskets shall be permitted.Exception No. 2: Nonmetallic gaskets used in insulating fittings shall be permitted.
3.2.15.4 Metallic tubing joints shall be flared or brazed using tubing and fittings in accordance with 2.4.3 and 2.4.4.
3.2.15.5 Piping in systems shall be run as directly as is practical from one point to another, with as few fittings as practical.
Where condensation of vapor can occur, piping shall be sloped back to the container or means shall be provided for revaporizing the condensate.
3.2.15.6 Piping systems including interconnecting of permanently installed containers shall compensate for expansion, contraction, jarring and vibration, and for settling. Using flexible connectors complying with 2.4.6 shall be permitted. The use of nonmetallic pipe, tubing, or hose for permanently interconnecting such containers shall be prohibited.
3.2.15.7 Aboveground piping shall be supported and protected against physical damage by vehicles. The portion of aboveground piping in contact with a support or a corrosion-causing substance shall be protected against corrosion.
3.2.15.8 Buried metallic pipe and tubing shall be installed underground with a minimum 18 in. (460 mm) of cover. The cover shall be permitted to be reduced to 12 in. (300 mm) if external damage to the pipe or tubing is not likely to result. If a minimum 12 in. (300 mm) of cover cannot be maintained, the piping shall be installed in conduit or shall be bridged (shielded). Where underground piping is beneath driveways, roads, or streets, possible damage by vehicles shall be taken into account.
3.2.15.9 Underground metallic piping shall be protected against corrosion as warranted by soil conditions (see 3.2.24).
3.2.15.10 LP-Gas piping shall not be used as a grounding electrode.
3.2.16 Polyethylene Pipe, Tubing, and Fittings.3.2.16.1 Polyethylene pipe, tubing and fittings shall be installed outdoors underground only.
3.2.16.2 Polyethylene pipe and tubing shall be buried as follows:
(1) With a minimum 18 in. (460 mm) of cover(2) With a minimum of 12 in. (300 mm) of cover if external damage to the pipe or tubing is not likely to result (3) If a minimum 12 in. (300 mm) of cover cannot be provided, with piping installed in conduit or bridged (shielded).
3.2.16.3 Assembled anodeless risers shall be used to terminate underground polyethylene piping systems above ground. The horizontal portion of risers shall be buried at least 12 in. (300mm) below grade and the casing material used for the risers shall be protected against corrosion in accordance with 3.2.24.
3.2.16.4 Either the aboveground portion of the riser casing shall be provided with a plastic sleeve inside the riser casing or the pipe or tubing shall be centered in the riser casing.
3.2.16.5 Factory-assembled risers shall be sealed and leak tested by the manufacturer.
![Page 236: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/236.jpg)
230 victormfg.com
Suggested method of Leak Checking 12SECTION
Gas Equipment Catalog
3.2.16.6 Field-assembled risers shall be supplied only in kit form with all necessary hardware for installation. Field-assembled risers shall comply with the following:
(1) Be design certified.(2) Be sealed and pressure tested by the installer.(3) Be assembled and installed in accordance with the riser manufacturer’s instructions.
3.2.16.7 The casing of the riser shall be constructed of one of the following materials:
(1) ASTM A 53, Standard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated Welded and Seamless, Schedule 40 steel pipe. (2) ASTM A 513, Standard Specification for Elec- tric-Resistance-Welded Carbon and Alloy Steel Mechanical Tubing, mechanical steel tubing with a minimum wall thickness of 0.073in. (1.9 mm).(3) A flexible metal tubing with a minimum crush strength of 1000 lb (453.6 kg) and a tensile strength of 300 lb (136 kg) including the tran- sition connection as tested by the manufacturer.
3.2.16.8* Polyethylene piping shall be installed so as to minimize thrust forces caused by contraction or expansion of the piping or by anticipated external or internal loading. The pipeline shall be designed and installed so that each joint will sustain these forces.
3.2.16.9 An electrically continuous corrosion-resistant tracer wire (minimum AWG 14) or tape shall be buried with the polyethylene pipe to facilitate locating. One end shall be brought aboveground at a building wall or riser. The wire or tape shall not be in direct contact with the polyethylene pipe.
3.2.16.10 Polyethylene piping that is installed in a vault or any other belowground enclosure shall be completely encased in gastight metal pipe and fittings that are protected from corrosion.
D. Suggested Method for Checking for Leakage* (continued)
* This section is an excerpt from the NFPA 54 National Fuel Gas Code — 1999 Edition
![Page 237: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/237.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ap
pen
dic
es
Gas Line Sizing
231
12SECTION
12
Table N-2B Low Pressure (Canada & USA 2 inch drop)*maximum Capacity of OmegaFlex TracPipe in Cubic Feet per Hour Natural Gas (1,000 BTU approximate)Gas Pressure: 7-8 inches W.C.; Pressure Drop: 2 inches W.C. (based on a 0.6 Specific Gravity Gas)
Size eHD
TUBING LeNGTH (FeeT)
5 10 15 20 25 30 40 50 60 70 80 90 100 150 200 250 3003/8” 15 115 82 67 58 52 48 42 37 34 32 30 28 27 22 19 17 151/2” 19 254 182 150 131 118 108 94 85 78 72 68 64 61 50 44 39 363/4” 25 564 403 331 288 258 237 206 185 169 157 147 139 132 108 94 84 771” 31 1038 734 599 518 463 423 366 327 299 276 259 244 231 189 163 146 133
11/4” 37 2191 1558 1277 1109 994 908 789 707 646 599 561 529 503 412 358 320 29311/2” 46 3607 2541 2070 1790 1599 1458 1261 1126 1027 950 888 837 793 646 559 499 455
2” 62 8257 5848 4780 4142 3707 3386 2934 2626 2398 2221 2078 1960 1860 1520 1317 1179 1076
* Tables above include losses for four 90-degree bends and two end fittings. Tubing runs with larger numbers of bends and/or fittings shall be increased by an equivalent length of tubing to the following equation: L = 1.3n where L is additional length of tubing and n is the number of additonal fittings and/or bends.
EHD (Effective Hydraulic Diameter) A relative measure of Flow Capacity; This number is used to compare individual sizes between different manufacturers. The higher the EHD number the greater flow capacity of the piping.
Table N-1 Low Pressure (Standard)*maximum Capacity of OmegaFlex TracPipe in Cubic Feet per Hour Natural Gas (1,000 BTU approximate)Gas Pressure: 6-7 inches W.C.; Pressure Drop: 0.5 inch W.C. (based on a 0.6 Specific Gravity Gas)
Size eHD
TUBING LeNGTH (FeeT)
5 10 15 20 25 30 40 50 60 70 80 90 100 150 200 250 3003/8” 15 63 44 35 31 27 25 21 19 17 16 15 14 13 10 9 8 71/2” 19 134 95 77 67 60 55 47 42 38 36 33 32 30 23 21 19 173/4” 25 288 206 169 147 132 121 105 94 86 80 75 71 67 55 48 43 391” 31 546 383 310 269 240 218 188 168 153 141 132 125 118 94 82 74 67
11/4” 37 1109 789 646 561 503 460 399 358 327 303 284 268 254 208 181 162 14811/2” 46 1790 1261 1027 888 793 723 625 559 509 471 440 415 393 320 277 247 226
2” 62 4142 2934 2398 2078 1860 1698 1472 1317 1203 1114 1042 983 933 762 661 591 540
Table N-2A Low Pressure (Canada & USA 1 inch drop)*maximum Capacity of OmegaFlex TracPipe in Cubic Feet per Hour Natural Gas (1,000 BTU approximate)Gas Pressure: 6-7 inches W.C.; Pressure Drop: 1 inch W.C. (based on a 0.6 Specific Gravity Gas)
Size eHD
TUBING LeNGTH (FeeT)
5 10 15 20 25 30 40 50 60 70 80 90 100 150 200 250 3003/8” 15 82 58 48 42 37 34 30 27 24 23 21 20 19 15 13 12 111/2” 19 182 131 108 94 85 78 68 61 56 52 48 46 44 36 31 28 263/4” 25 403 288 237 206 185 169 147 132 121 112 105 99 94 77 67 60 551” 31 734 518 423 366 327 299 259 231 211 195 183 172 163 133 115 103 94
11/4” 37 1558 1109 908 789 707 646 561 503 460 426 399 377 358 293 254 228 20811/2” 46 2541 1790 1458 1261 1126 1027 888 793 723 669 625 589 559 455 393 351 320
2” 62 5848 4142 3386 2934 2626 2398 2078 1860 1698 1573 1472 1388 1317 1076 933 835 762
![Page 238: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/238.jpg)
232 victormfg.com
Gas Line Sizing 12SECTION
Gas Equipment Catalog
Table N-3 Regulator Outlet (8 inches W.C.)*maximum Capacity of OmegaFlex TracPipe in Cubic Feet per Hour Natural Gas (1,000 BTU approximate)Gas Pressure: 8 inches W.C.; Pressure Drop: 3 inches W.C. (based on a 0.6 Specific Gravity Gas)
Size eHD
TUBING LeNGTH (FeeT)
5 10 15 20 25 30 40 50 60 70 80 90 100 150 200 250 3003/8” 15 160 112 90 78 69 63 54 48 44 41 38 36 34 27 23 21 191/2” 19 327 231 189 164 147 134 116 104 95 88 82 77 73 60 52 46 423/4” 25 687 491 403 351 315 288 250 225 206 191 179 169 160 132 115 103 941” 31 1365 958 778 672 599 546 471 421 383 355 331 311 295 240 207 184 168
11/4” 37 2673 1902 1558 1353 1213 1109 963 863 789 731 685 646 614 503 436 391 35811/2” 46 4428 3119 2541 2197 1963 1790 1548 1383 1261 1166 1090 1027 974 793 686 613 559
2” 62 10103 7156 5848 5069 4536 4142 3590 3213 2934 2717 2543 2398 2276 1860 1612 1442 1317
Table N-4 Medium Pressure*maximum Capacity of OmegaFlex TracPipe in Cubic Feet per Hour Natural Gas (1,000 BTU approximate)Gas Pressure: .5 psi (12-14 inches W.C.); Pressure Drop: 6 inch W.C. (based on a 0.6 Specific Gravity Gas)
Size eHD
TUBING LeNGTH (FeeT)
5 10 15 20 25 30 40 50 60 70 80 90 100 150 200 250 3003/8” 15 229 160 130 112 99 90 78 69 63 58 54 51 48 39 34 30 271/2” 19 461 327 267 231 207 189 164 147 134 124 116 109 104 85 73 66 603/4” 25 962 687 564 491 441 403 351 315 288 267 250 237 225 185 160 144 1321” 31 1946 1365 1110 958 855 778 672 599 546 505 471 444 421 342 295 263 240
11/4” 37 3757 2673 2191 1902 1704 1558 1353 1213 1109 1028 963 908 863 707 614 550 50311/2” 46 6286 4428 3607 3119 2786 2541 2197 1963 1790 1656 1548 1458 1383 1126 974 870 793
2” 62 14263 10103 8257 7156 6404 5848 5069 4536 4142 3837 3590 3386 3213 2626 2276 2036 1860
Table N-3A 3P (11 inches W.C.)*maximum Capacity of OmegaFlex TracPipe in Cubic Feet per Hour Natural GasGas Pressure: 11 inches W.C.; Pressure Drop: 5 inches W.C. (based on a 0.6 Specific Gravity Gas)
Size eHD
TUBING LeNGTH (FeeT)
5 10 15 20 25 30 40 50 60 70 80 90 100 150 200 250 3003/8” 15 207 144 116 100 89 81 70 62 56 52 48 45 43 35 30 26 241/2” 19 419 297 242 210 188 172 149 133 122 113 105 99 94 77 67 60 543/4” 25 878 627 515 448 402 368 320 287 263 244 228 216 205 168 146 131 1201” 31 1766 1237 1005 867 773 704 607 542 493 456 425 400 379 308 266 237 216
11/4” 37 3436 2444 2003 1739 1558 1425 1237 1109 1014 940 880 831 789 646 561 503 46011/2” 46 5732 4038 3290 2844 2541 2317 2004 1790 1632 1510 1411 1330 1261 1027 888 793 723
2” 62 13026 9227 7541 6535 5858 5341 4629 4142 3783 3504 3279 3092 2934 2398 2078 1860 1698
* Tables above include losses for four 90-degree bends and two end fittings. Tubing runs with larger numbers of bends and/or fittings shall be increased by an equivalent length of tubing to the following equation: L = 1.3n where L is additional length of tubing and n is the number of additonal fittings and/or bends. EHD (Effective Hydraulic Diameter) A relative measure of Flow Capacity; This number is used to compare individual sizes between different manufacturers. The higher the EHD number the greater flow capacity of the piping.
![Page 239: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/239.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ap
pen
dic
es
Gas Line Sizing
233
12SECTION
12
Table N-5A Elevated Pressure (2 psi)*maximum Capacity of OmegaFlex TracPipe in Cubic Feet per Hour Natural Gas (1,000 BTU approximate)Gas Pressure: 2 psi; Pressure Drop: 1.5 psi (based on a 0.6 Specific Gravity Gas)
Size eHD
TUBING LeNGTH (FeeT)
10 25 30 40 50 75 80 100 150 200 250 300 400 5003/8” 15 438 271 247 212 189 153 148 131 106 91 81 74 64 561/2” 19 855 542 495 429 384 314 304 272 222 193 172 157 136 1223/4” 25 1761 1129 1033 899 806 662 642 576 473 411 369 338 294 2641” 31 3687 2304 2098 1810 1614 1311 1268 1131 919 793 707 644 555 495
11/4” 37 6919 4412 4034 3502 3139 2572 2492 2233 1830 1589 1424 1302 1130 101311/2” 46 11782 7415 6762 5847 5223 4255 4119 3679 2997 2592 2315 2111 1826 1631
2” 62 26473 16781 15326 13282 11886 9715 9408 8419 6881 5963 5337 4874 4224 3780
Table N-5 Elevated Pressure (2 psi)*maximum Capacity of OmegaFlex TracPipe in Cubic Feet per Hour Natural Gas (1,000 BTU approximate)Gas Pressure: 2 psi; Pressure Drop: 1 psi (based on a 0.6 Specific Gravity Gas)
Size eHD
TUBING LeNGTH (FeeT)
10 25 30 40 50 75 80 100 150 200 250 300 400 5003/8” 15 353 220 200 172 154 124 120 107 87 75 67 61 52 461/2” 19 700 444 405 351 314 257 249 222 182 157 141 129 111 1003/4” 25 1444 926 847 737 661 543 527 473 388 338 303 277 241 2161” 31 2986 1869 1703 1470 1311 1066 1031 920 748 645 576 525 453 404
11/4” 37 5670 3615 3305 2870 2572 2108 2042 1830 1499 1302 1167 1067 926 83011/2” 46 9599 6041 5509 4763 4255 3467 3355 2997 2442 2111 1886 1720 1487 1329
2” 62 21637 13715 12526 10855 9715 7940 7689 6881 5624 4874 4362 3983 3452 3089
* Table does not include effect of pressure drop across the line regulator. If regulator loss exceeds 3/4 PSI (based on 8 inch outlet pressure, do not use this chart. Pressure drops across a regulator vary with flow rate. FGP-REG-5 has a 1 PSI pressure drop at a flow of 673 cubic feet per hour. CAUTION: Capacities shown in table may exceed maximum capacity for a selected regulator. Table does not include effect of pressure drop across the line regulator.
Table N-6 Elevated Pressure (5 psi)*maximum Capacity of OmegaFlex TracPipe in Cubic Feet per Hour Natural Gas (1,000 BTU approximate)Gas Pressure: 5 psi; Pressure Drop: 3.5 psi (based on a 0.6 Specific Gravity Gas)
Size eHD
TUBING LeNGTH (FeeT)
10 25 30 40 50 75 80 100 150 200 250 300 400 5003/8” 15 672 420 382 329 293 238 230 205 166 143 128 116 100 891/2” 19 1304 827 755 654 586 479 463 415 339 294 263 240 208 1863/4” 25 2650 1699 1556 1353 1214 998 967 868 713 620 556 509 443 3971” 31 5659 3543 3228 2786 2486 2021 1955 1744 1418 1224 1092 955 858 766
11/4” 37 10489 6688 6116 5310 4759 3899 3778 3386 2774 2409 2159 1974 1714 153611/2” 46 18080 11378 10377 8972 8015 6530 6320 5646 4600 3977 3553 3240 2802 2503
2” 62 40353 25580 23361 20246 18119 14809 14341 12834 10489 9090 8135 7430 6439 5762
![Page 240: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/240.jpg)
234 victormfg.com
Gas Line Sizing 12SECTION
Gas Equipment Catalog
Table P-2 Propane Medium Pressure*maximum Capacity of OmegaFlex TracPipe in Thousdands of BTU per Hour Propane GasGas Pressure: .5 psi (12-14 in. W.C.); Pressure Drop: 2.5 in. W.C. (based on a 1.52 Specific Gravity Gas)
Size eHD
TUBING LeNGTH (FeeT)
5 10 15 20 25 30 40 50 60 70 80 90 100 150 200 250 3003/8” 15 222 159 131 114 102 93 81 73 67 62 58 55 52 43 37 33 301/2” 19 491 353 290 254 228 209 182 164 150 140 131 124 118 97 85 76 703/4” 25 1094 782 642 559 501 459 399 358 328 304 285 269 256 210 183 164 1361” 31 2512 1863 1720 1343 1106 976 883 825 771 719 673 632 596 470 398 352 320
11/4” 37 3863 2749 2253 1955 1753 1603 1391 1247 1140 1056 990 934 887 727 631 566 51711/2” 46 6383 4496 3663 3168 2830 2580 2230 1993 1818 1682 1571 1481 1404 1143 988 884 805
2” 62 14586 10330 8443 7317 6547 5980 5183 4638 4236 3923 3671 3462 3285 2684 2327 2082 1902
Table P-3 Propane Elevated Pressure (2 psi)*maximum Capacity of OmegaFlex TracPipe in thousands of BTU per Hour Propane GasGas Pressure: 2 psi; Pressure Drop: 1 psi (based on a 1.52 Specific Gravity Gas)
Size eHD
TUBING LeNGTH (FeeT)
10 25 30 40 50 75 80 100 150 200 250 300 400 5003/8” 15 558 347 316 271 243 196 189 169 137 118 105 96 82 721/2” 19 1106 701 640 554 496 406 393 350 287 248 222 203 175 1583/4” 25 2282 1464 1340 1165 1046 859 833 748 614 534 479 439 381 3421” 31 4720 2954 2692 2323 2072 1685 1629 1454 1182 1019 910 829 716 638
11/4” 37 8963 5714 5224 4537 4066 3332 3228 2893 2370 2058 1845 1687 1464 131211/2” 46 15174 9549 8708 7529 6726 5480 5303 4738 3860 3337 2981 2719 2351 2101
2” 62 34203 21680 19801 17159 15357 12551 12154 10877 8890 7705 6895 6296 5457 4883
Table P-1 Propane Low Pressure (Standard)*maximum Capacity of OmegaFlex TracPipe in Thousands of BTU per Hour Propane GasGas Pressure: 11 inches W.C.; Pressure Drop: 0.5 W.C. (based on a 1.52 Specific Gravity Gas)
Size eHD
TUBING LeNGTH (FeeT)
5 10 15 20 25 30 40 50 60 70 80 90 100 150 200 250 3003/8” 15 99 69 55 49 42 39 33 30 26 25 23 22 20 15 14 12 111/2” 19 211 150 121 106 94 87 74 66 60 57 52 50 47 36 33 30 263/4” 25 456 325 267 232 209 191 166 149 136 126 118 112 106 87 76 68 621” 31 863 605 490 425 379 344 297 265 241 222 208 197 186 143 129 117 107
11/4” 37 1753 1247 1021 887 795 727 631 566 517 479 449 424 402 329 286 256 23411/2” 46 2830 1993 1623 1404 1254 1143 988 884 805 745 696 656 621 506 438 390 357
2” 62 6547 4638 3791 3285 2940 2684 2327 2082 1902 1761 1647 1554 1475 1205 1045 934 854
* Table does not include effect of pressure drop across the line regulator. If regulator loss exceeds 3/4 PSI (based on 8 inch outlet pressure, do not use this chart. Pressure drops across a regulator vary with flow rate. FGP-REG-5 has a 1 PSI pressure drop at a flow of 673 cubic feet per hour. CAUTION: Capacities shown in table may exceed maximum capacity for a selected regulator. Table does not include effect of pressure drop across the line regulator.
![Page 241: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/241.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ap
pen
dic
es
Gas Line Sizing
235
12SECTION
12
Table P-3A Propane Elevated Pressure (2 psi)*maximum Capacity of OmegaFlex TracPipe in Thousands of BTU per Hour Propane GasGas Pressure: 2 psi; Pressure Drop: 1.5 psi (based on a 1.52 Specific Gravity Gas)
Table P-4 Propane Elevated Pressure (5 psi)*maximum Capacity of OmegaFlex TracPipe in Thousands of BTU per Hour Propane GasGas Pressure: 5 psi; Pressure Drop: 3.5 psi (based on a 1.52 Specific Gravity Gas)
Size eHD
TUBING LeNGTH (FeeT)
10 25 30 40 50 75 80 100 150 200 250 300 400 5003/8” 15 817 525 481 419 376 310 300 269 222 193 173 159 138 1241/2” 19 1588 1041 957 839 757 628 609 550 456 399 360 331 290 2623/4” 25 3237 2147 1978 1739 1574 1312 1275 1153 962 845 765 705 619 5601” 31 6838 4436 4070 3553 3198 2641 2561 2305 1903 1661 1495 1372 1198 1078
11/4” 37 10937 6974 6377 5536 4962 4066 3939 3530 2893 2512 2251 2058 1786 160111/2” 46 18624 11721 10689 9243 8256 6726 6511 5816 4738 4097 3659 3337 2886 2578
2” 62 41847 26527 24227 20996 18789 15357 14872 13308 10877 9426 8436 7705 6677 5975
Size eHD
TUBING LeNGTH (FeeT)
10 25 30 40 50 75 80 100 150 200 250 300 400 5003/8” 15 1065 664 603 520 463 376 363 324 262 226 202 183 158 1401/2” 19 2061 1307 1193 1033 926 757 731 656 535 464 416 379 328 2943/4” 25 4189 2686 2459 2139 1920 1577 1529 1310 1127 980 880 805 700 6291” 31 8945 5600 5102 4404 3929 3194 3090 2756 2241 1934 1726 1572 1356 1210
11/4” 37 16581 10572 9668 8394 7523 6163 5972 5352 4796 4385 3808 3120 2709 242811/2” 46 28580 17986 16403 14183 12670 10322 9990 8925 7271 6287 5616 5122 4429 3957
2” 62 63788 40436 36928 32004 28642 23409 22670 20287 16581 14369 12859 11745 10178 9108
Victor/F.w. Webb stocks buderus boilers.
* Table does not include effect of pressure drop across the line regulator. If regulator loss exceeds 3/4 PSI (based on 8 inch outlet pressure, do not use this chart. Pressure drops across a regulator vary with flow rate. FGP-REG-5 has a 1 PSI pressure drop at a flow of 673 cubic feet per hour. CAUTION: Capacities shown in table may exceed maximum capacity for a selected regulator. Table does not include effect of pressure drop across the line regulator.
![Page 242: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/242.jpg)
236 victormfg.com
Gas Line Sizing 12SECTION
Gas Equipment Catalog
Propane 10# Table 6.3 (a) Schedule 40 Metallic Pipe
Note: All table entries are rounded to 3 significant digits.
NOmINAL INSIDe
PIPe SIze (INCHeS)1/2 3/4 1 11/4 11/2 2 21/2 3 4
ACTUAL 0.622 0.824 1.049 1.380 1.610 2.067 2.469 3.068 4.026LeNGTH (FeeT) CAPACITy IN THOUSANDS OF BTU PeR HOUR
1020304050
3,3202,2801,8301,5701,390
6,9504,7803,8403,2802,910
13,1009,0007,2206,1805,480
26,90018,50014,80012,70011,300
40,30027,70022,20019,00016,900
77,60053,30042,80036,60032,500
124,00085,00068,20058,40051,700
219,000150,000121,000103,00091,500
446,000306,000246,000211,000187,000
60708090100
1,2601,1601,0801,010956
2,6402,4302,2602,1202,000
4,9704,5704,2503,9903,770
10,2009,3808,7308,1907,730
15,30014,10013,10012,30011,600
29,40027,10025,20023,60022,300
46,90043,10040,10037,70035,600
82,90076,30070,90066,60062,900
169,000156,000145,000136,000128,000
125150175200250
848768706657582
1,7701,6101,4801,3701,220
3,3403,0202,7802,5902,290
6,8506,2105,7105,3204,710
10,3009,3008,5607,9607,060
19,80017,90016,50015,30013,600
31,50028,60026,30024,40021,700
55,70050,50046,50043,20038,300
114,000103,00094,70088,10078,100
300350400450500
528486452424400
1,1001,020945886837
2,0801,1901,7801,6701,580
4,2703,9303,6503,4303,240
6,4005,8805,4705,1404,850
12,30011,30010,5009,8909,340
19,60018,10016,80015,80014,900
34,70031,90029,70027,90026,300
70,80065,10060,60056,80053,700
550600650700750
380363347334321
795759726698672
1,5001,4301,3701,3101,270
3,0702,9302,8102,7002,600
4,6104,4004,2104,0403,900
8,8708,4608,1107,7907,500
14,10013,50012,90012,40012,000
25,00023,90022,80021,90021,100
51,00048,60046,60044,80043,100
800850900950
1,000
310300291283275
649628609592575
1,2201,1801,1501,1101,080
2,5102,4302,3602,2902,230
3,7603,6403,5303,4303,330
7,2407,0106,8006,6006,420
11,50011,20010,80010,50010,200
20,40019,80019,20018,60018,100
41,60040,30039,10037,90036,900
1,1001,2001,3001,4001,500
261249239229221
546521499480462
1,030982940903870
2,1102,0201,9301,8501,790
3,1703,0202,8902,7802,680
6,1005,8205,5705,3505,160
9,7209,2708,8808,5308,220
17,20016,40015,70015,10014,500
35,00033,40032,00030,80029,600
1,6001,7001,8001,9002,000
213206200194189
446432419407395
840813789766745
1,7301,6701,6201,5701,530
2,5902,5002,4302,3602,290
4,9804,8204,6704,5404,410
7,9407,6807,4507,2307,030
14,00013,60013,20012,80012,400
28,60027,70026,90026,10025,400
SPECIAL USE: Pipe Sizing Between First Stage (High Pressure Regulator) and Second Stage (Low Pressure Regulator)Gas Undiluted PropaneInlet Pressure 10.0 psiPressure Drop 1.0 psiSpecific Gravity 1.50
This section is an excerpt from the NFPA 54 National Fuel Gas Code — 2006 Edition
![Page 243: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/243.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ap
pen
dic
es
Gas Line Sizing
237
12SECTION
12
Propane 2# Table 6.3 (c) Schedule 40 Metallic Pipe
Note: All table entries are rounded to 3 significant digits.
NOmINALPIPe SIze (INCHeS)
1/2 3/4 1 11/4 11/2 2 21/2 3 4ACTUAL
ID 0.622 0.824 1.049 1.380 1.610 2.067 2.469 3.068 4.026LeNGTH (FeeT) CAPACITy IN THOUSANDS OF BTU PeR HOUR
1020304050
2,6801,8401,4801,2601,120
5,5903,8503,0902,6402,340
10,5007,2405,8204,9804,410
21,60014,90011,90010,2009,060
32,40022,30017,90015,30013,600
62,40042,90034,50029,50026,100
99,50068,40054,90047,00041,700
176,000121,00097,10083,10073,700
359,000247,000198,000170,000150,000
60708090100
1,010934869815770
2,1201,9501,8201,7001,610
4,0003,6803,4203,2103,030
8,2107,5507,0206,5906,230
12,30011,30010,5009,8809,330
23,70021,80020,30019,00018,000
37,70034,70032,30030,30028,600
66,70061,40057,10053,60050,600
136,000125,000116,000109,000103,000
125150175200250
682618569529469
1,4301,2901,1901,110981
2,6902,4402,2402,0801,850
5,5205,0004,6004,2803,790
8,2707,4906,8906,4105,680
15,90014,40013,30012,30010,900
25,40023,00021,20019,70017,400
44,90040,70037,40034,80030,800
91,50082,90076,30071,00062,000
300350400450500
425391364341322
889817760714674
1,6701,5401,4301,3401,270
3,4403,1602,9402,7602,610
5,1504,7404,4104,1303,910
9,9209,1208,4907,9607,520
15,80014,50013,50012,70012,000
27,90025,70023,90022,40021,200
57,00052,40048,80045,80043,200
550600650700750
306292280269259
640611585562541
1,2101,1501,1001,0601,020
2,4802,3602,2602,1702,090
3,7103,5403,3903,2603,140
7,1406,8206,5306,2706,040
11,40010,90010,4009,9909,630
20,10019,20018,40017,70017,000
41,10039,20037,50036,00034,700
800850900950
1,000
250242235228222
523506490476463
985953924897873
2,0201,9601,9001,8401,790
3,0302,9302,8402,7602,680
5,8305,6405,4705,3105,170
9,3009,0008,7208,4708,240
16,40015,90015,40015,00014,600
33,50032,40031,50030,50029,700
1,1001,2001,3001,4001,500
210201192185178
440420402386372
829791757727701
1,7001,6201,5501,4901,440
2,5502,4302,3302,2402,160
4,9104,6804,4904,3104,150
7,8307,4707,1506,8706,620
13,80013,20012,60012,10011,700
28,20026,90025,80024,80023,900
1,6001,7001,8001,9002,000
172166161157152
359348337327318
677655635617600
1,3901,3401,3001,2701,230
2,0802,0101,9501,9001,840
4,0103,8803,7603,6503,550
6,3906,1806,0005,8205,660
11,30010,90010,60010,30010,000
23,00022,30021,60021,00020,400
Gas Undiluted PropaneInlet Pressure 2.0 psiPressure Drop 1.0 psiSpecific Gravity 1.50
This section is an excerpt from the NFPA 54 National Fuel Gas Code — 2006 Edition
![Page 244: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/244.jpg)
238 victormfg.com
Gas Line Sizing 12SECTION
Gas Equipment Catalog
Propane 11” W.C.Table 6.3 (d) Schedule 40 Metallic Pipe
Note: All table entries are rounded to 3 significant digits.
NOmINAL INSIDe
PIPe SIze (INCHeS)1/2 3/4 1 11/4 11/2 2 21/2 3 4
ACTUAL 0.622 0.824 1.049 1.380 1.610 2.067 2.469 3.068 4.026LeNGTH (FeeT) CAPACITy IN THOUSANDS OF BTU PeR HOUR
1020304050
291200160137122
608418336287255
1,150787632541480
2,3501,6201,3001,110985
3,5202,4201,9401,6601,480
6,7904,6603,7503,2102,840
10,8007,4305,9705,1104,530
19,10013,10010,6009,0308,000
39,00026,80021,50018,40016,300
6080100125150
110101948984
231212197185175
434400372349330
892821763716677
1,3401,2301,1401,0701,010
2,5702,3702,2002,0701,950
4,1003,7703,5103,2903,110
7,2506,6706,2105,8205,500
14,80013,60012,70011,90011,200
175200250300350
7467625851
155140129120107
292265243227201
600543500465412
899814749697618
1,7301,5701,4401,3401,190
2,7602,5002,3002,1401,900
4,8804,4204,0603,7803,350
9,9509,0108,2907,7106,840
400450500550600
4642403735
9789837873
182167156146138
373344320300283
560515479449424
1,080991922865817
1,7201,5801,4701,3801,300
3,0402,7902,6002,4402,300
6,1905,7005,3004,9704,700
650700750800850
3332302928
7066646159
131125120115111
269257246236227
403385368354341
776741709681656
1,2401,1801,1301,0901,050
2,1902,0902,0001,9201,850
4,4604,2604,0803,9203,770
900950
1,0001,1001,200
2726252524
5755535250
1071041009795
220213206200195
329319309300292
634613595578562
1,010978948921895
1,7901,7301,6801,6301,580
3,6403,5303,4203,3203,230
1,3001,4001,5001,6001,700
2322212019
4846444240
9086827976
185176169162156
277264253243234
534509487468451
850811777746719
1,5001,4301,3701,3201,270
3,0702,9302,8002,6902,590
1,8001,9002,000
191818
393837
747169
151146142
226219212
436422409
694672652
1,2301,1901,150
2,5002,4202,350
SPECIAL USE: Pipe Sizing Between Single or Second Stage (Low Pressure Regulator) and ApplianceGas Undiluted PropaneInlet Pressure 11.0 inches W.C.Pressure Drop 0.5 inches W.C.Specific Gravity 1.50
This section is an excerpt from the NFPA 58 Liquefied Petroleum Gas Code — 2008 Edition
![Page 245: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/245.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ap
pen
dic
es
Gas Line Sizing
239
12SECTION
12
Propane 10# Table 6.3 (e) Semi-Rigid Copper Tubing
Note: All table entries are rounded to 3 significant digits. * Table capacities are based on Type K copper tubing inside diameter (shown), which has the smallest inside diameter of the copper tubing products.
NOmINAL
TUBe SIze (INCHeS)k & L 1/4 3/8 1/2 5/8 3/4 1 11/4 11/2 2ACR 3/8 1/2 5/8 3/4 7/8 11/8 13/8 — —
OUTSIDe 0.375 0.500 0.625 0.750 0.875 1.125 1.375 1.625 2.125INSIDe* 0.305 0.402 0.527 0.652 0.745 0.995 1.245 1.481 1.959LeNGTH(FeeT) CAPACITy IN THOUSANDS OF BTU PeR HOUR
1020304050
513352283242215
1,060727584500443
2,1501,4801,1901,020901
3,7602,5802,0801,7801,570
5,3303,6702,9402,5202,230
11,4007,8306,2905,3804,770
20,50014,10011,3009,6908,590
32,30022,20017,90015,30013,500
67,40046,30037,20031,80028,200
60708090100
194179166156147
401369343322304
816751699655619
1,4301,3101,2201,1501,080
2,0201,8601,7301,6301,540
4,3203,9803,7003,4703,280
7,7807,1606,6606,2505,900
12,30011,30010,5009,8509,310
25,60023,50021,90020,50019,400
125150175200250
13111810910190
270244225209185
549497457426377
959869799744659
1,3601,2301,1301,060935
2,9102,6302,4202,2502,000
5,2304,7404,3604,0603,600
8,2507,4706,8806,4005,670
17,20015,60014,30013,30011,800
300350400450500
8175706562
168155144135127
342314292274259
597549511480453
847779725680643
1,8101,6601,5501,4501,370
3,2603,0002,7902,6202,470
5,1404,7304,4004,1303,900
10,7009,8409,1608,5908,120
550600650700750
5956545150
121115111106102
246235225216208
430410393378364
610582558536516
1,3001,2401,1901,1401,100
2,3502,2402,1402,0601,980
3,7003,5303,3803,2503,130
7,7107,3507,0406,7706,520
800850900950
1,000
4846454442
9996939088
201195189183178
351340330320311
498 482468454442
1,0601,0301,000970944
1,9201,8501,8001,7501,700
3,0202,9202,8402,7502,680
6,2906,0905,9105,7305,580
1,1001,2001,3001,4001,500
4038373534
8379767370
169161155148143
296282270260250
420400383368355
896855819787758
1,6101,5401,4701,4201,360
2,5402,4302,3202,2302,150
5,3005,0504,8404,6504,480
1,6001,7001,8001,9002,000
3332313029
6866646260
138134130126122
241234227220214
343331321312304
732708687667648
1,3201,2701,2401,2001,170
2,0802,0101,9501,8901,840
4,3304,1904,0603,9403,830
SPECIAL USE: Tube Sizing Between First Stage (High Pressure Regulator) and Second Stage (Low Pressure Regulator)Gas Undiluted PropaneInlet Pressure 10.0 psiPressure Drop 1.0 psiSpecific Gravity 1.50
This section is an excerpt from the NFPA 54 National Fuel Gas Code — 2006 Edition
![Page 246: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/246.jpg)
240 victormfg.com
Gas Line Sizing 12SECTION
Gas Equipment Catalog
Propane 2# Table 6.3 (g) Semi-Rigid Copper Tubing
Note: All table entries are rounded to 3 significant digits. * Table capacities are based on Type K copper tubing inside diameter (shown), which has the smallest inside diameter of the copper tubing products.
NOmINAL
TUBe SIze (INCHeS)k & L 1/4 3/8 1/2 5/8 3/4 1 11/4 11/2 2ACR 3/8 1/2 5/8 3/4 7/8 11/8 13/8 — —
OUTSIDe 0.375 0.500 0.625 0.750 0.875 1.125 1.375 1.625 2.125INSIDe* 0.305 0.402 0.527 0.652 0.745 0.995 1.245 1.481 1.959LeNGTH(FeeT) CAPACITy IN THOUSANDS OF BTU PeR HOUR
1020304050
413284228195173
852585470402356
1,7301,190956818725
3,0302,0801,6701,4301,270
4,3002,9502,3702,0301,800
9,1706,3105,0604,3303,840
16,50011,4009,1207,8006,920
26,00017,90014,40012,30010,900
54,20037,30029,90025,60022,700
60708090100
157144134126119
323297276259245
657605562528498
1,1501,060983922871
1,6301,5001,3901,3101,240
3,4803,2002,9802,7902,640
6,2705,7605,3605,0304,750
9,8809,0908,4507,9307,490
20,60018,90017,60016,50015,600
125150175200250
10595888272
217197181168149
442400368343304
772700644599531
1,100992913849753
2,3402,1201,9501,8101,610
4,2103,8203,5103,2702,900
6,6406,0205,5405,1504,560
13,80012,50011,50010,7009,510
300350400450500
6660565350
135124116109103
275253235221209
481442411386365
682628584548517
1,4601,3401,2501,1701,110
2,6202,4102,2502,1101,990
4,1403,8003,5403,3203,140
8,6107,9207,3706,9206,530
550600650700750
4745434140
9793898682
198189181174168
346330316304293
491469449431415
1,0501,000959921888
1,8901,8001,7301,6601,600
2,9802,8402,7202,6202,520
6,2105,9205,6705,4505,250
800850900950
1,000
3937363534
8077757271
162157152147143
283274265258251
401388376366356
857829804781760
1,5401,4901,4501,4101,370
2,4302,3502,2802,2202,160
5,0704,9004,7504,6204,490
1,1001,2001,3001,4001,500
3231302827
6764615957
136130124120115
238227217209201
338322309296286
721688659633610
1,3001,2401,1901,1401,100
2,0501,9501,8701,8001,730
4,2704,0703,9003,7403,610
1,6001,7001,8001,9002,000
2626252423
5553515048
11110810410199
194188182177172
276267259251244
589570553537522
1,0601,0301,000966940
1,6701,6201,5701,5201,480
3,4803,3703,2703,1703,090
Gas Undiluted PropaneInlet Pressure 2.0 psiPressure Drop 1.0 psiSpecific Gravity 1.50
This section is an excerpt from the NFPA 54 National Fuel Gas Code — 2006 Edition
![Page 247: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/247.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ap
pen
dic
es
Gas Line Sizing
241
12SECTION
12
Propane 11” W.C.Table 6.3 (f) Semi-Rigid Copper Tubing
NA means a flow of less than 10,000 BTU/hr.Note: All table entries are rounded to 3 significant digits. * Table capacities are based on Type K copper tubing inside diameter (shown), which has the smallest inside diameter of the copper tubing products.
SPECIAL USE: Tube Sizing Between Single or Second Stage (Low Pressure Regulator) and ApplianceGas Undiluted PropaneInlet Pressure 11.0 inches W.C.Pressure Drop 0.5 inches W.C.Specific Gravity 1.50
NOmINAL
TUBe SIze (INCHeS)k & L 1/4 3/8 1/2 5/8 3/4 1 11/4 11/2 2ACR 3/8 1/2 5/8 3/4 7/8 11/8 13/8 — —
OUTSIDe 0.375 0.500 0.625 0.750 0.875 1.125 1.375 1.625 2.125INSIDe* 0.305 0.402 0.527 0.652 0.745 0.995 1.245 1.481 1.959LeNGTH(FeeT) CAPACITy IN THOUSANDS OF BTU PeR HOUR
1020304050
4531252119
9364514439
1881291048979
329226182155138
467321258220195
997685550471417
1,8001,230991848752
2,8301,9501,5601,3401,180
5,8904,0503,2502,7802,470
60708090100
1716151413
3532302827
7166615754
12511510710095
177163152142134
378348324304287
681626583547517
1,070988919862814
2,2402,0601,9101,8001,700
125150175200250
1110NANANA
2421201816
4844403733
8476706558
119108999282
254230212197175
458415382355315
722654602560496
1,5001,3601,2501,1701,030
300350400450500
NANANANANA
1514131211
3028262423
5248454240
7468636056
158146136127120
285262244229216
449414385361341
936861801752710
550600650700750
NANANANANA
1110NANANA
2221201918
3836343332
5351494745
11410910410096
205196188180174
324309296284274
674643616592570
800850900950
1,000
NANANANANA
NANANANANA
1817171616
3130292827
4442414039
9390878583
168162157153149
264256248241234
551533517502488
1,1001,2001,3001,4001,500
NANANANANA
NANANANANA
1514141313
2625242322
3735343231
7875726966
141135129124119
223212203195188
464442423407392
1,6001,7001,8001,9002,000
NANANANANA
NANANANANA
1212111111
2120201919
3029282727
6462605857
115112108105102
182176170166161
378366355345335
This section is an excerpt from the NFPA 58 Liquefied Petroleum Gas Code — 2008 Edition
![Page 248: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/248.jpg)
242 victormfg.com
Gas Line Sizing 12SECTION
Gas Equipment Catalog
Propane 10#Table 15.1 (o) Polyethylene Plastic
Note: (1) Maximum undiluted propane capacities listed are based on a pressure of 10 psig first-stage setting and 1 psi pressure drop. Capacities in 1000 BTU/hr.(2) Dimensions in parentheses are inside diameter.
SPECIAL USE: Pipe Sizing Between First Stage and Second Stage RegulatorsGas Undiluted PropaneInlet Pressure 10 psiPressure Drop 1 psiSpecific Gravity 1.50
NOmINAL OD
NOmINAL OUTSIDe DIAmeTeR (IPS)PIPe SIze (INCHeS)
1/2 3/4 1 11/4 11/2 2DeSIGNATION SDR 9.33 SDR 11.0 SDR 10.00 SDR 11.00 SDR 11.00 SDR 11.0
ACTUAL ID (0.660) (0.860) (1.077) (1.328) (1.554) (1.943)LeNGTH (FeeT) CAPACITy IN THOUSANDS OF BTU PeR HOUR
30 2,143 4,292 7,744 13,416 20,260 36,40240 1,835 3,673 6,628 11,482 17,340 31,15550 1,626 3,256 5,874 10,176 15,368 27,61260 1,473 2,950 5,322 9,220 13,924 25,01970 1,355 2,714 4,896 8,483 12,810 23,01780 1,261 2,525 4,555 7,891 11,918 21,41390 1,183 2,369 4,274 7,404 11,182 20,091100 1,117 2,238 4,037 6,994 10,562 18,978125 990 1,983 3,578 6,199 9,361 16,820150 897 1,797 3,242 5,616 8,482 15,240175 826 1,653 2,983 5,167 7,803 14,020200 778 1,539 2,775 4,807 7,259 13,043225 721 1,443 2,603 4,510 6,811 12,238250 681 1,363 2,459 4,260 6,434 11,560275 646 1,294 2,336 4,046 6,111 10,979300 617 1,235 2,228 3,860 5,830 10,474350 567 1,136 2,050 3,551 5,363 9,636400 528 1,057 1,907 3,304 4,989 8,965450 495 992 1,789 3,100 4,681 8,411500 468 937 1,690 2,928 4,422 7,945600 424 849 1,531 2,653 4,007 7,199700 390 781 1,409 2,441 3,686 6,623800 363 726 1,311 2,271 3,429 6,161900 340 682 1,230 2,131 3,217 5,7811000 322 644 1,162 2,012 3,039 5,4611500 258 517 933 1,616 2,441 4,3852000 221 443 798 1,383 2,089 3,753
This section is an excerpt from the NFPA 58 Liquefied Petroleum Gas Code — 2008 Edition
![Page 249: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/249.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ap
pen
dic
es
Gas Line Sizing
243
12SECTION
12
Propane 11” W.C. Table 6.3 (k) Polyethylene Plastic Pipe
Note: All table entries are rounded to 3 significant digits.
NOmINAL OD PIPe SIze (INCHeS)
1/2 3/4 1 11/4 11/2 2DeSIGNATION SDR 9.33 SDR 11.00 SDR 11.00 SDR 10.00 SDR 11.00 SDR 11.00
ACTUAL ID 0.660 0.860 1.077 1.328 1.554 1.943LeNGTH (FeeT) CAPACITy IN THOUSANDS OF BTU PeR HOUR
1020304050
340233187160142
680468375321285
1,230844677580514
2,1301,4601,1701,000890
3,2102,2101,7701,5201,340
5,7703,9703,1802,7302,420
60708090100
12911911010398
258237221207196
466428398374353
807742690648612
1,2201,1201,040978924
2,1902,0101,8701,7601,660
125150175200250
8778726760
173157145135119
313284261243215
542491452420373
819742683635563
1,4701,3301,2301,1401,010
300350400450500
5450464341
10899928782
195179167157148
338311289271256
510469436409387
916843784736695
Gas Undiluted PropaneInlet Pressure 11.0 inches W.C.Pressure Drop 0.5 inches W.C.Specific Gravity 1.50
This section is an excerpt from the NFPA 54 National Fuel Gas Code — 2006 Edition
Victor/F.w. Webb isweil mclain’s largest distributor.
![Page 250: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/250.jpg)
244 victormfg.com
Gas Line Sizing 12SECTION
Gas Equipment Catalog
Propane 10#Table 15.1 (p) Polyethylene Plastic
Propane 11” W.C.Table 15.1 (q) Polyethylene Plastic
Note: (1) Maximum undiluted propane capacities listed are based on a pressure of 10 psig first-stage setting and 1 psi pressure drop. Capacities in 1000 BTU/hr.(2) Dimensions in parentheses are inside diameter.
SPECIAL USE: Tube Sizing Between First Stage and Second Stage RegulatorsGas Undiluted PropaneInlet Pressure 10 psiPressure Drop 10 psiSpecific Gravity 1.50
SPECIAL USE: Tube Sizing Between First Stage and Second Stage RegulatorsGas Undiluted PropaneInlet Pressure 11.0 inches W.C.Pressure Drop 0.5 inches W.C.Specific Gravity 1.50
NOmINAL OD
NOmINAL OUTSIDe DIAmeTeR (CTS)PIPe SIze (INCHeS)
1/2 1DeSIGNATION SDR 7.00 SDR 11.00
ACTUAL ID (0.445) (0.927)
LeNGTH (FeeT)CAPACITy IN THOUSANDS
OF BTU PeR HOUR30 762 5,22540 653 4,47250 578 3,96460 524 3,59170 482 3,30480 448 3,07490 421 2,884100 397 2,724125 352 2,414150 319 2,188175 294 2,013200 273 1,872225 256 1,757250 242 1,659275 230 1,576300 219 1,503350 202 1,383400 188 1,287450 176 1,207500 166 1,140600 151 1,033700 139 951800 129 884900 121 8301000 114 7841500 92 6292000 79 539
NOmINAL OD
NOmINAL OUTSIDe DIAmeTeR (CTS)PIPe SIze (INCHeS)
1/2 1DeSIGNATION SDR 7.00 SDR 11.00
ACTUAL ID (0.445) (0.927)
LeNGTH (FeeT)CAPACITy IN THOUSANDS
OF BTU PeR HOUR10 121 82920 83 56930 67 45740 57 39150 51 34760 46 31470 42 28980 39 26990 37 252100 35 238125 31 211150 28 191175 26 176200 24 164225 22 154250 21 145275 20 138300 19 132350 18 121400 16 113
Note: (1) Maximum undiluted propane capacities listed are based on a pressure of 11 in. W.C. setting and a 0.5 in. W.C. pressure drop. Capacities in 1000 BTU/hr.(2) Dimensions in parentheses are inside diameter.
This section is an excerpt from the NFPA 58 Liquefied Petroleum Gas Code — 2008 Edition
![Page 251: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/251.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ap
pen
dic
es
Gas Line Sizing
245
12SECTION
12
Natural Gas Low PressureTable 6.2(b) Schedule 40 Metallic Pipe
NA means a flow of less than 10,000 BTU/hr.Note: All table entries are rounded to 3 significant digits.
Gas NaturalInlet Pressure Less than 2 psiPressure Drop 0.5 inches W.C.Specific Gravity 0.60
NOmINAL
PIPe SIze (INCHeS)
1/2 3/4 1 11/4 11/2 2 21/2 3 4 5 6 8 10 12ACTUAL ID 0.622 0.824 1.049 1.380 1.610 2.067 2.469 3.068 4.026 5.047 6.065 7.981 10.020 11.938LeNGTH(FeeT) CAPACITy IN CUBIC FeeT OF GAS PeR HOUR
1020304050
172 118958172
360247199170151
678466374320284
1,390957768657583
2,0901,4301,150985873
4,0202,7602,2202,9001,680
6,4004,4003,5303,0202,680
11,3007,7806,2505,3504,740
23,100 15,90012,70010,9009,660
41,80028,70023,00019,70017,500
67,60046,50037,30031,90028,300
139,00095,50076,70065,60058,200
252,000173,000139,000119,000106,000
399,000275,000220,000189,000167,000
60708090100
6560565250
137126117110104
257237220207195
528486452424400
791728677635600
1,5201,4001,3001,2201,160
2,4302,2302,0801,9501,840
4,2903,9503,6703,4503,260
8,7608,0507,4907,0306,640
15,80014,60013,60012,70012,000
25,60023,60022,00020,60019,500
52,70048,50045,10042,30040,000
95,70088,10081,90076,90072,600
152,000139,000130,000122,000115,000
125150175200250
4440373430
9283777163
173157144134119
355322296275244
532482443412366
1,020928854794704
1,6301,4801,3601,2701,120
2,8902,6102,4102,2401,980
5,8905,3304,9104,5604,050
10,6009,6508,8808,2607,320
17,20015,60014,40013,40011,900
35,40032,10029,50027,50024,300
64,30058,30053,60049,90044,200
102,00092,30084,90079,00070,000
300350400450500
2725232221
5753494643
10899928682
221203189177168
331305283266251
638587546512484
1,020935870816771
1,8001,6501,5401,4401,360
3,6703,3703,1402,9402,780
6,6306,1005,6805,3305,030
10,7009,8809,1908,6208,150
22,10020,30018,90017,70016,700
40,10036,90034,30032,20030,400
63,40058,40054,30050,90048,100
550600650700750
2019181717
4139383635
7874716866
159152145140135
239228218209202
459438420403389
732699669643619
1,2901,2401,1801,1401,090
2,6402,5202,4102,3202,230
4,7804,5604,3604,1904,040
7,7407,3807,0706,7906,540
15,90015,20014,50014,00013,400
28,90027,50026,40025,30024,400
45,70043,60041,80040,10038,600
800850900950
1,000
1616151514
3433323130
6361595856
130126122118115
195189183178173
375363352342333
598579561545530
1,0601,020992963937
2,1602,0902,0201,9601,910
3,9003,7803,6603,5503,460
6,3206,1105,9305,7605,600
13,00012,60012,20011,80011,500
23,60022,80022,10021,50020,900
37,30036,10035,00034,00033,100
1,1001,2001,3001,4001,500
1413121211
2827262524
5351494745
1091041009693
164156150144139
316301289277267
503480460442426
890849813781752
1,8101,7301,6601,5901,530
3,2803,1303,0002,8802,780
5,3205,0704,8604,6704,500
10,90010,4009,9809,5909,240
19,80018,90018,10017,40016,800
31,40030,00028,70027,60026,600
1,6001,7001,8001,9002,000
11111010NA
2322222120
4442414039
8986848179
134130126122119
258250242235229
411398386375364
727703682662644
1,4801,4301,3901,3501,310
2,6802,5902,5202,4402,380
4,3404,2004,0703,9603,850
8,9208,6308,3708,1307,910
16,20015,70015,20014,80014,400
25,60024,80024,10023,40022,700
This section is an excerpt from the NFPA 54 National Fuel Gas Code — 2006 Edition
![Page 252: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/252.jpg)
246 victormfg.com
Gas Line Sizing 12SECTION
Gas Equipment Catalog
Natural Gas 2#Table 6.2(c) Schedule 40 Metallic Pipe
Note: All table entries are rounded to 3 significant digits.
Gas NaturalInlet Pressure 2.0 psiPressure Drop 1.0 psiSpecific Gravity 0.60
NOmINAL
PIPe SIze (INCHeS)
1/2 3/4 1 11/4 11/2 2 21/2 3 4ACTUAL ID 0.622 0.824 1.049 1.380 1.610 2.067 2.469 3.068 4.026LeNGTH(FeeT) CAPACITy IN CUBIC FeeT OF GAS PeR HOUR
1020304050
1,5101,070869753673
3,0402,1501,7601,5201,360
5,5603,9303,2102,7802,490
11,4008,0706,5905,7105,110
17,10012,1009,8808,5507,650
32,90023,20019,00016,50014,700
52,50037,10030,30026,40023,500
92,80065,60053,60046,40041,500
189,000134,000109,00094,70084,700
60708090100
615569532502462
1,2401,1501,0801,010934
2,2702,1001,9701,8501,710
4,6604,3204,0403,8103,510
6,9806,4706,0505,7005,260
13,50012,50011,70011,00010,100
21,40019,90018,60017,50016,100
37,90035,10032,80030,90028,500
77,30071,60067,00063,10058,200
125150175200250
414372344318279
836751695642583
1,5301,3701,2701,1701,040
3,1402,8202,6012,4102,140
4,7004,2203,9103,6103,210
9,0608,1307,5306,9606,180
14,40013,00012,00011,1009,850
25,50022,90021,20019,60017,400
52,10046,70043,30040,00035,500
300350400450500
253232216203192
528486452424401
945869809759717
1,9401,7901,6601,5601,470
2,9102,6702,4902,3302,210
5,60051504,7904,5004,250
8,9208,2107,6407,1706,770
15,80014,50013,50012,70012,000
32,20029,60027,50025,80024,400
550600650700750
182174166160154
381363348334322
681650622598576
1,4001.3301,2801,2301,180
2,0902,0001,9101,8401,770
4,0303,8503,6803,5403,410
6,4306,1305,8705,6405,440
11,40010,80010,4009,9709,610
23,20022,10021,20020,30019,600
800850900950
1,000
149144139135132
311301292283275
556538522507493
1,1401,1001,0701,0401,010
1,7101,6501,6001,5601,520
3,2903,1903,0903,0002,920
5,2505,0804,9304,7804,650
9,2808,9808,7108,4608,220
18,90018,30017,80017,20016,800
1,1001,2001,3001,4001,500
125119114110106
262250239230221
468446427411396
960917878843812
1,4401,3701,3201,2601,220
2,7702,6402,5302,4302,340
4,4204,2204,0403,8803,740
7,8107,4507,1406,8606,600
15,90015,20014,60014,00013,500
1,6001,7001,8001,9002,000
10299969391
214207200195189
382370358348339
784759736715695
1,1801,1401,1001,0701,040
2,2602,1902,1202,0602,010
3,6103,4903,3903,2903,200
6,3806,1705,9805,8105,650
13,00012,60012,20011,90011,500
This section is an excerpt from the NFPA 54 National Fuel Gas Code — 2006 Edition
![Page 253: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/253.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ap
pen
dic
es
Gas Line Sizing
247
12SECTION
12
Natural Gas 5#Table 6.2(e) Schedule 40 Metallic Pipe
Note: All table entries are rounded to 3 significant digits.
Gas NaturalInlet Pressure 5.0 psiPressure Drop 3.5 psiSpecific Gravity 0.60
NOmINAL
PIPe SIze (INCHeS)
1/2 3/4 1 11/4 11/2 2 21/2 3 4ACTUAL ID 0.622 0.824 1.049 1.380 1.610 2.067 2.469 3.068 4.026LeNGTH(FeeT) CAPACITy IN CUBIC FeeT OF GAS PeR HOUR
1020304050
3,1902,2501,8401,5901,430
6,4304,5503,7203,2202,880
11,8008,3206,7905,8805,260
24,20017,10014,00012,10010,800
36,20025,60020,90018,10016,200
69,70049,30040,30034,90031,200
111,00078,60064,20055,60049,700
196,000139,000113,00098,20087,900
401,000283,000231,000200,000179,000
60708090100
1,3001,2001,1501,060979
2,6302,4302,3302,1501,980
4,8004,4504,2603,9203,620
9,8609,1308,5408,0507,430
14,80013,70012,80012,10011,100
28,50026,40024,70023,20021,400
45,40042,00039,30037,00034,200
80,20074,30069,50065,50060,400
164,000151,000142,000134,000123,000
125150175200250
876786728673558
1,7701,5901,4701,3601,170
3,2402,9102,6902,4902,200
6,6405,9605,5205,1004,510
9,9508,9408,2707,6506,760
19,20017,20015,90014,70013,000
30,60027,40025,40023,50020,800
54,00048,50044,90041,50036,700
110,00098,90091,60084,70074,900
300350400450500
506 465433406384
1,060973905849802
1,9901,8301,7101,6001,510
4,0903,7603,5003,2903,100
6,1305,6405,2504,9204,650
11,80010,90010,1009,4808,950
18,80017,30016,10015,10014,300
33,30030,60028,50026,70025,200
67,80062,40058,10054,50051,500
550600650700750
364348333320308
762727696669644
1,4401,3701,3101,2601,210
2,9502,8102,6902,5902,490
4,4204,2104,0303,8803,730
8,5008,1107,7707,4607,190
13,60012,90012,40011,90011,500
24,00022,90021,90021,00020,300
48,90046,60044,60042,90041,300
800850900950
1,000
298288279271264
622602584567551
1,1701,1301,1001,0701,040
2,4102,3302,2602,1902,130
3,6103,4903,3803,2903,200
6,9406,7206,5206,3306,150
11,10010,70010,40010,1009,810
19,60018,90018,40017,80017,300
39,90038,60037,40036,40035,400
1,1001,2001,3001,4001,500
250239229220212
524400478460443
987941901866834
2,0301,9301,8501,7801,710
3,0302,9002,7702,6602,570
5,8405,5805,3405,1304,940
9,3208,8908,5108,1807,880
16,50015,70015,00014,50013,900
33,60032,00030,70029,50028,400
1,6001,7001,8001,9002,000
205198192186181
428414401390379
806 780756734714
1,6501,6001,5501,5101,470
2,4802,4002,3302,2602,200
4,7704,6204,4804,3504,230
7,6107,3607,1406,9306,740
13,40013,00012,60012,30011,900
27,40026,50025,70025,00024,300
This section is an excerpt from the NFPA 54 National Fuel Gas Code — 2006 Edition
![Page 254: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/254.jpg)
248 victormfg.com
Gas Line Sizing 12SECTION
Gas Equipment Catalog
Natural Gas Low PressureTable 6.2(g) Semi-Rigid Copper Tubing
NA means a flow of less than 10 cfh.Note: All table entries are rounded to 3 significant digits. * Table capacities are based on Type K copper tubing inside diameter (shown), which has the smallest inside diameter of the copper tubing products.
Gas NaturalInlet Pressure Less than 2.0 psiPressure Drop 0.5 inches W.C.Specific Gravity 0.60
NOmINAL
PIPe SIze (INCHeS)
k & L 1/4 3/8 1/2 5/8 3/4 1 11/4 11/2 2
ACTUAL ID ACR 3/8 1/2 5/8 3/4 7/8 11/8 13/8 — —
OUTSIDe 0.375 0.500 0.625 0.750 0.875 1.125 1.375 1.625 2.125INSIDe* 0.305 0.402 0.527 0.652 0.745 0.995 1.245 1.481 1.959LeNGTH(FeeT) CAPACITy IN CUBIC FeeT OF GAS PeR HOUR
1020304050
2718151311
5538302623
11177615347
1951341079282
276190152131116
590406326279247
1,060730586502445
1,6801,150925791701
3,4902,4001,9301,6501,460
60708090100
10NANANANA
2119181716
4239363432
7468635956
10596908479
224206192180170
403371345324306
635585544510482
1,3201,2201,1301,0601,000
125150175200250
NANA NANANA
14131211NA
2826242220
5045413934
7064595548
151136125117103
271245226210186
427387356331294
890806742690612
300350400450500
NANA NANANA
NANA NANANA
1816151413
3128262523
4440383533
9486807571
169155144135128
266245228214202
554510474445420
550600650700750
NANA NANANA
NANA NANANA
1312121111
2221202019
3230292827
6864625957
122116111107103
192183175168162
399381365350338
800850900950
1,000
NANA NANANA
NANA NANANA
1010 NANANA
1818171716
2625242423
5553525049
9996939088
156151147143139
326315306297289
1,1001,2001,3001,4001,500
NANA NANANA
NANA NANANA
NANA NANANA
1515141313
2221201918
4644424139
8480767371
132126120116111
274262251241232
1,6001,7001,8001,9002,000
NANA NANANA
NANA NANANA
NANA NANANA
1312121111
1817171616
3837363534
6866646260
1081041019895
224217210204199
This section is an excerpt from the NFPA 54 National Fuel Gas Code — 2006 Edition
![Page 255: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/255.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ap
pen
dic
es
Gas Line Sizing
249
12SECTION
12
Natural Gas 2#Table 6.2(j) Semi-Rigid Copper Tubing
Note: All table entries are rounded to 3 significant digits.* Table capacities are based on Type K copper tubing inside diameter (shown), which has the smallest inside diameter of the copper tubing products.
Gas NaturalInlet Pressure 2.0 psiPressure Drop 1.0 psiSpecific Gravity 0.60
NOmINAL
TUBe SIze (INCHeS)
k & L 1/4 3/8 1/2 5/8 3/4 1 11/4 11/2 2
ACR 3/8 1/2 5/8 3/4 7/8 11/8 13/8 — —OUTSIDe 0.375 0.500 0.625 0.750 0.875 1.125 1.375 1.625 2.125INSIDe* 0.305 0.402 0.527 0.652 0.745 0.995 1.245 1.481 1.959LeNGTH(FeeT) CAPACITy IN CUBIC FeeT OF GAS PeR HOUR
1020304050
245169135116103
506348279239212
1,030708568486431
1,8001,240993850754
2,5501,7601,4101,2101,070
5,4503,7503,0102,5802,280
9,8206,7505,4204,6404,110
15,50010,6008,5507,3106,480
32,20022,20017,80015,20013,500
60708090100
9386807571
192177164154146
391359334314296
683628584548518
969891829778735
2,0701,9001,7701,6601,570
3,7303,4303,1902,9902,830
5,8705,4005,0304,7204,450
12,20011,30010,5009,8209,280
125150175200250
6357524943
12911710810089
263238219204181
459416383356315
651590543505448
1,3901,2601,1601,080956
2,5002,2702,0901,9401,720
3,9503,5803,2903,0602,710
8,2207,4506,8506,3805,650
300350400450500
3936333130
8074696561
164150140131124
286263245230217
406373347326308
866797741696657
1,5601,4301,3301,2501,180
2,4602,2602,1001,9701,870
5,1204,7104,3804,1103,880
550600650700750
2827262524
5855535149
118112108103100
206196188181174
292279267256247
624595570548528
1,1201,0701,030986950
1,7701,6901,6201,5501,500
3,6903,5203,3703,2403,120
800850900950
1,000
2322222120
4746444342
9693908885
168163158153149
239231224217211
510493478464452
917888861836813
1,4501,4001,3601,3201,280
3,0102,9202,8302,7402,670
1,1001,2001,3001,4001,500
1918181716
4038363534
8177747168
142135129124120
201192183176170
429409392376363
772737705678653
1,2201,1601,1101,0701,030
2,5402,4202,3202,2302,140
1,6001,7001,8001,9002,000
1615151414
3331303029
6664626059
116112108105102
164159154149145
350339329319310
630310592575559
994962933906881
2,0702,0001,9401,8901,830
This section is an excerpt from the NFPA 54 National Fuel Gas Code — 2006 Edition
![Page 256: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/256.jpg)
250 victormfg.com
Gas Line Sizing 12SECTION
Gas Equipment Catalog
Natural Gas 5#Table 6.2(l) Semi-Rigid Copper Tubing
Note: All table entries are rounded to 3 significant digits.* Table capacities are based on Type K copper tubing inside diameter (shown), which has the smallest inside diameter of the copper tubing products.
Gas NaturalInlet Pressure 5.0 psiPressure Drop 3.5 psiSpecific Gravity 0.60
NOmINAL
PIPe SIze (INCHeS)
k & L 1/4 3/8 1/2 5/8 3/4 1 11/4 11/2 2
ACR 3/8 1/2 5/8 3/4 7/8 11/8 13/8 — —OUTSIDe 0.375 0.500 0.625 0.750 0.875 1.125 1.375 1.625 2.125INSIDe* 0.305 0.402 0.527 0.652 0.745 0.995 1.245 1.481 1.959LeNGTH(FeeT) CAPACITy IN CUBIC FeeT OF GAS PeR HOUR
1020304050
511351382241214
1,050724582498441
2,1401,4701,1801,010898
3,7502,5802,0701,7701,570
5,3203,6502,9302,5102,230
11,4007,8006,2705,3604,750
20,40014,00011,3009,6608,560
32,20022,20017,80015,20013,500
67,10046,10037,00031,70028,100
60708090100
194178166156147
400368342321303
813748696653617
1,4201,3101,2201,1401,080
2,0201,8601,7301,6201,530
4,3103,9603,6903,4603,270
7,7507,1306,6406,2305,880
12,20011,20010,5009,8209,270
25,50023,40021,80020,40019,300
125150175200250
13011810910190
269243224208185
547495456424376
955866796741657
1,3601,2301,1301,050932
2,9002,6202,4102,2501,990
5,2104,7204,3504,0403,580
8,2207,4506,8506,3705,650
17,10015,50014,30013,30011,800
300350400450500
8175696562
167154143134127
340313291273258
595547509478451
844777722678640
1,8001,6601,5401,4501,370
3,2502,9902,7802,6102,460
5,1204,1704,3804,1103,880
10,7009,8109,1208,5608,090
550600650700750
5856535149
121115110106102
245234224215207
429409392376362
608580556534514
1,3001,2401,1901,1401,100
2,3402,2302,1402,0501,980
3,6903,5203,3703,2403,120
7,6807,3307,0206,7406,490
800850900950
1,000
4846454342
9895929087
200194188182177
350339328319310
497481466452440
1,0601,0301,000967940
1,9101,8501,7901,7401,690
3,0102,9102,8202,7402,670
6,2706,0705,8805,7105,560
1,1001,2001,3001,4001,500
4038373534
8379767370
169161154148143
295281269259249
418399382367353
893852816784755
1,6101,5301,4701,4101,360
2,5302,4202,3202,2202,140
5,2805,0404,8204,6304,460
1,6001,7001,8001,9002,000
3332313229
6865636260
138133129125122
241233226219213
341330320311302
729705684664646
1,3101,2701,2301,2001,160
2,0702,0001,9401,8901,830
4,3104,1704,0403,9303,820
This section is an excerpt from the NFPA 54 National Fuel Gas Code — 2006 Edition
![Page 257: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/257.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ap
pen
dic
es
Gas Line Sizing
251
12SECTION
12
Natural Gas Low PressureTable 6.2(s) Polyethylene Plastic Pipe
Note: All table entries are rounded to 3 significant digits.
Gas NaturalInlet Pressure Less than 2 psiPressure Drop 0.5 inches in W.C.Specific Gravity 0.60
NOmINAL ODPIPe SIze (INCHeS)
1/2 3/4 1 11/4 11/2 2DeSIGNATION SDR 9.33 SDR 11.00 SDR 11.00 SDR 10.00 SDR 11.00 SDR 11.00
ACTUAL ID 0.660 0.860 1.077 1.328 1.554 1.943LeNGTH(FeeT) CAPACITy IN CUBIC FeeT OF GAS PeR HOUR
1020304050
2011381119584
403277222190169
726499401343304
1,260865695594527
1,9001,3101,050898796
3,4102,3501,8801,6101,430
60708090100
7670656158
153140131123116
276254236221209
477439409383362
721663617579547
1,3001,1901,1101,040983
125150175200250
5146434035
10393868071
185168154144127
321291268249221
485439404376333
871789726675598
300350400450500
3229272624
6459555148
115106999388
200184171160152
302278258242229
542499464435411
This section is an excerpt from the NFPA 54 National Fuel Gas Code — 2006 Edition
![Page 258: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/258.jpg)
252 victormfg.com
Gas Line Sizing 12SECTION
Gas Equipment Catalog
Natural Gas 2#Table 6.2(t) Polyethylene Plastic Pipe
Note: All table entries are rounded to 3 significant digits.
Gas NaturalInlet Pressure 2.0 psiPressure Drop 1.0 psiSpecific Gravity 0.60
NOmINAL ODPIPe SIze (INCHeS)
1/2 3/4 1 11/4 11/2 2DeSIGNATION SDR 9.33 SDR 11.00 SDR 11.00 SDR 10.00 SDR 11.00 SDR 11.00
ACTUAL ID 0.660 0.860 1.077 1.328 1.554 1.943LeNGTH(FeeT) CAPACITy IN CUBIC FeeT OF GAS PeR HOUR
1020304050
1,8601,2801,030878778
3,7202,5602,0501,7601,560
6,7104,6103,7103,1702,810
11,6007,9906,4205,4904,870
17,60012,1009,6908,3007,350
31,60021,70017,40014,90013,200
60708090100
705649603566535
1,4101,3001,2101,1301,070
2,5502,3402,1802,0501,930
4,4104,0603,7803,5403,350
6,6606,1305,7005,3505.050
12,00011,00010,2009,6109,080
125150175200250
474429395368326
949860791736652
1,7101,5501,4301,3301,180
2,9702,6902,4702,3002,040
4,4804,0603,7303,4703,080
8,0507,2906,7106,2405,530
300350400450500
295272253237224
591544506475448
1,070981913856809
1,8501,7001,5801,4801,400
2,7902,5702,3902,2402,120
5,0104,6104,2904,0203,800
550600650700750
213203194187180
426406389374360
768733702674649
1,3301,2701,2201,1701,130
2,0101,9201,8401,7601,700
3,6103,4403,3003,1703,050
800850900950
1,000
174168163158154
348336326317308
627607588572556
1,0901,0501,020990963
1,6401,5901,5401,5001,450
2,9502,8502,7702,6902,610
1,1001,2001,3001,4001,500
146139134128124
293279267257247
528504482463446
915873836803773
1,3801,3201,2601,2101,170
2,4802,3702,2702,1802,100
1,6001,7001,8001,9002,000
119115112109106
239231224218212
431417404393382
747723701680662
1,1301,0901,0601,0301,000
2,0301,9601,9001,8501,800
This section is an excerpt from the NFPA 54 National Fuel Gas Code — 2006 Edition
![Page 259: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/259.jpg)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ap
pen
dic
es
Gas Line Sizing
253
12SECTION
12
Natural Gas Low PressureTable 6.2 (u) Polyethylene Plastic Tubing
Natural Gas 2#Table 6.2 (v) Polyethylene Plastic Tubing
Gas NaturalInlet Pressure Less than 2.0 psiPressure Drop 0.3 inches W.C.Specific Gravity 0.60
Gas NaturalInlet Pressure Less than 2.0 psiPressure Drop 0.5 inches W.C.Specific Gravity 0.60
NOmINAL OD
PLASTIC TUBING SIze (CTS)*PIPe SIze (INCHeS)
1/2 3/4
DeSIGNATION SDR 7.00 SDR 11.00ACTUAL ID 0.445 0.927
LeNGTH (FeeT)CAPACITy IN CUBIC FeeT OF
GAS PeR HOUR1020304050
5437302623
372256205176156
60708090100
2119181716
141130121113107
125150175200
14131211
95867974
225250275300
10NANANA
69656259
350400450500
NANANANA
54514745
NOmINAL OD
PLASTIC TUBING SIze (CTS)*PIPe SIze (INCHeS)
1/2 3/4
DeSIGNATION SDR 7.00 SDR 11.00ACTUAL ID (0.445) (0.927)
LeNGTH (FeeT)CAPACITy IN THOUSANDS
OF BTU PeR HOUR1020304050
7249393430
490337271232205
60708090100
2725232221
186171159149141
125150175200
18171514
12511310497
225250275300
13121111
91868278
350400450500
10NANANA
72676359
* CTS = Copper tube size.NA means a flow of less than 10 cfh.Note: All table entries are rounded to 3 significant digits. This section is an excerpt from the NFPA 54 National Fuel Gas Code — 2006 Edition
![Page 260: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/260.jpg)
![Page 261: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/261.jpg)
GAS INDEX
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
![Page 262: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/262.jpg)
![Page 263: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/263.jpg)
Gas Index
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004 i
A Accessories, Meters & Meter Accessories . . . . . . . 89Adapters, Connectors & Fittings, Valves & Accessories . . . . . . . . . . . . . . . . . . . .64-68Aluminum Tubing, Gas Heating. . . . . . . . . . . . . . . 166Anodes, Cylinders, Tanks & Accessories . . . . . . . . 98Appendices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213
Gas Line Sizing . . . . . . . . . . . . . . . . . . . . . .231-253Leak Checking Method . . . . . . . . . . . . . . . .228-230Liquid Volume Tables & Temperature Correction Factors . . . . . . . . . . . . . . . . . . .225-226LP Container Requirements . . . . . . . . . . . .213-222Orifice Sizing & Propertites of LP Gases . . .223-224Vaporizer & Electrical Requirements . . . . . . . . . 227
Application Diagrams, Valves & Accessories . . .75-77ASME & Dot Cylinders, Cylinders, Tanks & Accessories . . . . . . . . . . . . . . . . . . . . .90-93ASME Tanks, Cylinders, Tanks & Accessories . . .94-95
B Ball Valves, Valves & Accessories. . . . . . . . . . . .49-52Barbed Hose Fittings, Gas Pipe, Tubing & Fittings . . . . . . . . . . . . . . . . . . . . . . . . . 139Black Iron Fittings, Gas Pipe, Tubing & Fittings . . . . . . . . . . . . . . . . . . . . . .140-143Brackets, Regulators & Accessories . . . . . . . . . . . . 10Bulk Hose, Gas Pipe, Tubing & Fittings . . . . . . . . 123Bypass Valves, Pumps & Compressors . . . . .193-194
C Chemicals, Tools & Chemicals . . . . . . . . . . . . . . . 211Coated Copper Tubing, Gas Pipe, Tubing & Fittings . . . . . . . . . . . . . . . . . . . . . . . . . 122Compressor Kits, Pumps & Compressors. . . . . . . 179Compressor Selection Tables, Pumps & Compressors . . . . . . . . . . . . . . . . . . . . 192Compressors, Pumps & Compressors . . . . . . . . . 191Continental Fittings, Gas Pipe, Tubing & Fittings . . . . . . . . . . . . . . . . . . . . . .129-133Copper Tubing, Gas Pipe, Tubing & Fittings . . . . . 122Counter Strike, Gas Pipe, Tubing & Fittings . . . . . 119Cylinders, Tanks & Accessories. . . . . . . . . . . . . . . . 90
Anodes, Cylinders . . . . . . . . . . . . . . . . . . . . . . . . 98ASME & Dot Cylinders . . . . . . . . . . . . . . . . . .90-93ASME Replacement Parts, . . . . . . . . . . . . . . . . 101ASME Tanks . . . . . . . . . . . . . . . . . . . . . . . . . .94-95Cylinder Cabinets . . . . . . . . . . . . . . . . . . . . . . . . 96Cylinder Inverters . . . . . . . . . . . . . . . . . . . . . . . . 96Cylinder Pads . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Cylinders, Tanks & Accessories. . . . . . . . . . . . . . . . 90
Cylinder Vice . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96Hand Trucks . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97Methanol Injector . . . . . . . . . . . . . . . . . . . . . . . . . 97Motor Fuel Cylinders . . . . . . . . . . . . . . . . . . . . . . 91OPD Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97Pipe Wrap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98Scales . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96Technical Information. . . . . . . . . . . . . . . . . . .98-101Temperature Monitoring System . . . . . . . . . . . . . 95
Cylinder & Service Valves, Valves & Accessories . . . . . . . . . . . . . . . . . . . .30-32Cylinder Cabinets, Cylinders, Tanks & Accessories . . . . . . . . . . . . . . . . . . . . . . . 96Cylinder Gauges, Gauges . . . . . . . . . . . . . . . . 107-115Cylinder Inverters, Cylinders, Tanks & Accessories. . . 96Cylinder Pads, Cylinders, Tanks & Accessories . . . 92Cylinder Vice, Cylinders, Tanks & Accessories . . . . 96
D Decals & Signs, Paint & Supplies . . . . . . . . . .104-106Disconnects, Miscellaneous Equipment . . . . . . . . 209Dormont Connectors, Gas Pipe, Tubing & Fittings . . . . . . . . . . . . . . . . . . . . . .134-136
E Excess Flow Valves, Valves & Accessories. . . . .53-61
F Filler Valves, Valves & Accessories . . . . . . . . . . . . . 60Fireplace Products, Miscellaneous Equipment . . . 210Fittings, Regulators & Accessories . . . . . . . . . . . . .8-9Flex Connectors, Pumps & Compressors . . . . . . . 177Flow Meters, Pumps & Compressors . . . . . . . . . . 177Forged Steel Fittings, Gas Pipe, Tubing & Fittings . . . . . . . . . . . . . . . . . . . . . .144-148
G Gas Conversion Burners, Miscellaneous Equipment . . . . . . . . . . . . . . . . . . 207Gas Heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
Aluminum Tubing. . . . . . . . . . . . . . . . . . . . . . . . 166Gas Leak System . . . . . . . . . . . . . . . . . . . . . . . 173Gas Orifices . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166Gas Valve Pressure Regulators. . . . . . . . . . . . . 169Gas Valves. . . . . . . . . . . . . . 155-158, 160-162, 169Hot Surface Igniters . . . . . . . . . . . . . . . . . . .170-172Ignition & Pilot Modules . . . . . . . . . . . . . . . .149-153Ignitors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152Pilot Burners . . . . . . . . . . . . . . . . . . . . . . . . . . . 167Pilot Kits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168
![Page 264: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/264.jpg)
Gas Index
ii victormfg.comGas Equipment Catalog
G Gas Heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
Pilots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159, 163Retrofit Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159Thermocouple & Thermopiles . . . . . . . . . . .163-164Thermostats. . . . . . . . . . . . . . . . . . . . . . . . . . . . 159Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165Water Feed Kit. . . . . . . . . . . . . . . . . . . . . . . . . . 173Water Heater Controls . . . . . . . . . . . . . . . . .154-155Water Safety Valves . . . . . . . . . . . . . . . . . . . . . 173
Gas Leak System, Gas Heating . . . . . . . . . . . . . . 173Gas Lights, Miscellaneous Equipment . . . . . . . . . 210Gas Line Sizing, Appendices. . . . . . . . . . . . . .231-253Gas Orifices, Gas Heating. . . . . . . . . . . . . . . . . . . 166Gas Outlet Boxes, Miscellaneous Equipment . . . . 209Gas Pipe, Tubing & Fittings. . . . . . . . . . . . . . . . . . 118
Barbed Hose Fittings . . . . . . . . . . . . . . . . . . . . . 139Black Iron Fittings . . . . . . . . . . . . . . . . . . . .140-143Bulk Hose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123Coated Copper Tubing . . . . . . . . . . . . . . . . . . . 122Continental Fittings . . . . . . . . . . . . . . . . . . .129-133Copper Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . 122Counter Strike . . . . . . . . . . . . . . . . . . . . . . . . . . 119Dormont Connectors . . . . . . . . . . . . . . . . . .134-136Forged Steel Fittings . . . . . . . . . . . . . . . . . .144-148Lyall Piping Systems . . . . . . . . . . . . . . . . . .124-128LycoFit Mechanical Fittings . . . . . . . . . . . . . . . . 124LycoFit Tapping Tees . . . . . . . . . . . . . . . . . . . . . 126LycoFit Installation Tools . . . . . . . . . . . . . . . . . . 127LycoRing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128SAE Fittings. . . . . . . . . . . . . . . . . . . . . . . . .137-138Sediment Traps . . . . . . . . . . . . . . . . . . . . . . . . . 123TracPipe . . . . . . . . . . . . . . . . . . . . . . . . . . . 118-121Underground PE Pipe . . . . . . . . . . . . . . . . . . . . 123
Gas Valve Pressure Regulators, Gas Heating . . . 169Gas Valves, Gas Heating . . . . 155-158, 160-162, 169Gauges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
Cylinder Gauges . . . . . . . . . . . . . . . . . . . . . 107-115Pressure Gauges. . . . . . . . . . . . . . . . . . . . . . . . 117Replacement Parts . . . . . . . . . . . . . . . . . . . . . . 116Tank Gauges . . . . . . . . . . . . . . . . . . . . . . . . 107-115
Gauge Products, Regulators & Accessories . . . . . . . 9Generators, Miscellaneous Equipment . . . . . .205-206Globe & Angle Valves, Valves & Accessories . . .44-48
H Hand Trucks, Cylinders, Tanks & Accessories . . . . 97Hose Reels, Pumps & Compressors. . . . . . . .175-176Hot Surface Igniters, Gas Heating. . . . . . . . . .170-172
I Ignition & Pilot Modules, Gas Heating. . . . . . .149-153Ignitors, Gas Heating. . . . . . . . . . . . . . . . . . . . . . . 152Internal Vales & Accessories, Valves & Accessories . . . . . . . . . . . . . . . . . . . .62-63
L Leak Checking Method, Appendices . . . . . . . .228-230Leak Detectors, Tools & Chemicals. . . . . . . . . . . . 211Lighters, Tools & Chemicals . . . . . . . . . . . . . . . . . 211Liquid Volume Tables & Temperature Correction Factors, Appendices . . . . . . . . . .225-226LP Container Requirements, Appendices . . . .213-222Lyall Piping Systems, Gas Pipe, Tubing & Fittings . . . . . . . . . . . . . . . . . . . . . .124-128Lyco Fittings, Gas Pipe, Tubing & Fittings. . . .124-128LycoFit Mechanical Fittings, Gas Pipe, Tubing & Fittings . . . . . . . . . . . . . . . . . . . . . . . . . 124LycoFit Tapping Tees, Gas Pipe, Tubing & Fittings . . . . . . . . . . . . . . . . . . . . . . . . . 126LycoFit Installation Tools, Gas Pipe, Tubing & Fittings . . . . . . . . . . . . . . . . . . . . . . . . . 127LycoRing, Gas Pipe, Tubing & Fittings . . . . . . . . . 128
M Manifolds, Meters & Meter Accessories . . . . . . . . . 88Manifolds, Regulators & Accessories . . . . . . . . . . . 10Meters & Meter Accessories . . . . . . . . . . . . . . . . . . 86
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89Manifolds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88Meters Bars . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89Meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .86-87
Meters Bars, Meters & Meter Accessories . . . . . . . 89Meters, Meters & Meter Accessories. . . . . . . . . .86-87Methanol Injector, Cylinders, Tanks & Accessories . 97Miscellaneous Equipment . . . . . . . . . . . . . . . . . . . 207
Disconnects . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209Fireplace Products. . . . . . . . . . . . . . . . . . . . . . . 210Gas Conversion Burners . . . . . . . . . . . . . . . . . . 207Gas Lights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210Gas Outlet Boxes . . . . . . . . . . . . . . . . . . . . . . . 209Generators. . . . . . . . . . . . . . . . . . . . . . . . . .205-206Vaporizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 208
Miscellanous Equipment, Valves & Accessories . . . . . . . . . . . . . . . . . . . .69-74Motor Fuel Cylinders, Cylinders, Tanks & Accessories. . . . . . . . . . . . . . . . . . . . . . . . 91Motors, Pumps & Compressors . . . . . . . . . . .195-197Multivalve Assemblies, Valves & Accessories . . .33-36
![Page 265: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/265.jpg)
Gas Index
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004 iii
O OPD Tools, Cylinders, Tanks & Accessories . . . . . . 97Orifice Sizing & Propertites of LP Gases, Appendices . . . . . . . . . . . . . . . . . . . . . . . . . .223-224
P Paint & Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . 102
Decals & Signs . . . . . . . . . . . . . . . . . . . . . .104-106Tank Paint & Supplies . . . . . . . . . . . . . . . . .102-103
Pigtails, Regulators & Accessories . . . . . . . . . . . . .7-8Pilot Burners, Gas Heating . . . . . . . . . . . . . . . . . . 167Pilot Kits, Gas Heating . . . . . . . . . . . . . . . . . . . . . 168Pilots, Gas Heating . . . . . . . . . . . . . . . . . . . . 163, 168Pipe Wrap, Cylinders, Tanks & Accessories . . . . . . 98POL Fittings, Regulators & Accessories . . . . . . . . . 10Pressure Gauges, Gauges . . . . . . . . . . . . . . . . . . 117Pressure Relief Valves & Relief Valve Manifolds, Valves & Accessories . . . . . . . . . . . . . . . . . . . . .37-43Propane Flare, Tools & Chemicals . . . . . . . . . . . . 211Propane Pumps, Pumps & Compressors . . . .185-190Pumps & Compressors . . . . . . . . . . . . . . . . . . . . . 175
Bypass Valves . . . . . . . . . . . . . . . . . . . . . . .193-194Compressor Kits . . . . . . . . . . . . . . . . . . . . . . . . 179Compressor Selection Tables . . . . . . . . . . . . . . 192Compressors . . . . . . . . . . . . . . . . . . . . . . . . . . . 191Flex Connectors . . . . . . . . . . . . . . . . . . . . . . . . 177Flow Meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177Hose Reels . . . . . . . . . . . . . . . . . . . . . . . . .175-176Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . .195-197Positive Displacement Meters, . . . . . . . . . . . . . 174Propane Pumps. . . . . . . . . . . . . . . . . . . . . .185-190Pump Station Kits . . . . . . . . . . . . . . . . . . . .180-184Repair Parts. . . . . . . . . . . . . . . . . . . . . . . . .197-204Strainers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177Swivel Connectors. . . . . . . . . . . . . . . . . . . . . . . 178
Pump Station Kits, Pumps & Compressors. . .180-184
R Regulators & Accessories . . . . . . . . . . . . . . . . . . . . . 1
Brackets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-9Gauge Products. . . . . . . . . . . . . . . . . . . . . . . . . . . 9Manifolds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 Pigtails . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-8POL Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Regulator Accessories. . . . . . . . . . . . . . . . . . . . . . 6Regulators . . . . . . . . . . . . . . . . . . . . . . . . 1-5, 11-29
Regulator Accessories, Regulators & Accessories . . 6Regulators, Regulators & Accessories . . . . 1-5, 11-29Repair Kits, Valves & Accessories. . . . . . . . . . . .78-85
Repair Parts, Pumps & Compressors . . . . . . .197-204Replacement Parts, Cylinders, Tanks & Accessories . . . . . . . . . . . . . . . . . . . . . . 101Replacement Parts, Gauges . . . . . . . . . . . . . . . . . 116Retrofit Kits, Gas Heating . . . . . . . . . . . . . . . . . . . 159
S SAE Fittings, Gas Pipe, Tubing & Fittings . . . .137-138Scales, Cylinders, Tanks & Accessories . . . . . . . . . 96Sediment Traps, Gas Pipe, Tubing & Fittings . . . . 123Strainers, Pumps & Compressors . . . . . . . . . . . . . 177Swivel Connectors, Pumps & Compressors . . . . . 178
T Tank Gauges, Gauges. . . . . . . . . . . . . . . . . . . 107-115Tank Paint & Supplies, Paint & Supplies . . . . .102-103Technical Information, Cylinders, Tanks & Accessories . . . . . . . . . . . . . . . . . . . .98-101Temperature Monitoring System, Cylinders, Tanks & Accessories . . . . . . . . . . . . . . . . . . . . . . . 95Test Gauge Kit, Tools & Chemicals . . . . . . . . . . . . 211Test Kits, Tools & Chemicals . . . . . . . . . . . . . . . . . 212Thermocouple & Thermopiles, Gas Heating . .163-164Thermostats, Gas Heating . . . . . . . . . . . . . . . . . . 159Tools & Chemicals. . . . . . . . . . . . . . . . . . . . . . . . . 211
Chemicals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211Leak Detectors . . . . . . . . . . . . . . . . . . . . . . . . . 211Lighters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211Propane Flare . . . . . . . . . . . . . . . . . . . . . . . . . . 211Test Gauge Kit . . . . . . . . . . . . . . . . . . . . . . . . . . 211Test Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212
Tools, Gas Heating . . . . . . . . . . . . . . . . . . . . . . . . 165TracPipe, Gas Pipe, Tubing & Fittings. . . . . . . 118-121
U Underground PE Pipe, Gas Pipe, Tubing & Fittings . . . . . . . . . . . . . . . . . . . . . . . . . 123
V Valves & Accessories . . . . . . . . . . . . . . . . . . . . . . . 30
Adapters, Connectors & Fittings . . . . . . . . . . .64-68Application Diagrams. . . . . . . . . . . . . . . . . . . .75-77Ball Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . .49-52Cylinder & Service Valve . . . . . . . . . . . . . . . . .30-32Excess Flow Valve. . . . . . . . . . . . . . . . . . . . . .53-61Filler Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60Globe & Angle Valves . . . . . . . . . . . . . . . . . . .44-48Internal Vales & Accessories . . . . . . . . . . . . . .62-63Miscellanous Equipment,. . . . . . . . . . . . . . . . .69-74Multivalve Assemblies . . . . . . . . . . . . . . . . . . .33-36Pressure Relief Valves & Relief Valve Manifolds 37-43
![Page 266: gas-catalog-2011.pdf](https://reader031.fdocuments.net/reader031/viewer/2022022207/55cf9be7550346d033a7ccc4/html5/thumbnails/266.jpg)
Gas Index
iv victormfg.comGas Equipment Catalog
V Valves & Accessories . . . . . . . . . . . . . . . . . . . . . . . 30
Repair Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . .78-85Vapor Equalizing Valves . . . . . . . . . . . . . . . . . . . 60
Vapor Equalizing Valves, Valves & Accessories . . . 60Vaporizer & Electrical Requirements, Appendices 227Vaporizers, Miscellaneous Equipment. . . . . . . . . . 208
W Water Feed Kit, Gas Heating. . . . . . . . . . . . . . . . . 173Water Heater Controls, Gas Heating. . . . . . . .154-155Water Safety Valves, Gas Heating . . . . . . . . . . . . 173