Gamma Calibrator_Memory Mode Rev 00

1

description

OK

Transcript of Gamma Calibrator_Memory Mode Rev 00

  • #1 THEVENAZ INDUSTRIAL TRAILSYLVAN LAKE, ALBERTA, CANADA T4S 2J6

    TEL: 403-887-2443FAX: 403-887-4050

    TITLE

    SIZEITEM NO. REVISION

    DATE MODIFIEDCHECKED SHEET

    UNLESS OTHERWISE SPECIFIED:

    The information contained herein is proprietary and may not be reproduced, usedor disclosed without prior consent by SPARTEK SYSTEMS INC.

    ALL DIMENSIONS IN INCHES

    SPARTEK SYSTEMSGEOPHYSICAL INSTRUMENTATION

    LEVEL63

    X.XXX: u 0.005 Xv: u 1vX.XX: u 0.01 X.Xv: u .5vOD: +0.001 / -0.002 DRILLED: O u 0.005 MACHINE FINISH

    1) REMOVE ALL BURR: R .010 MAX2) INSIDE ALL CORNERS: R .010 MAX 3) O TO BE WITHIN .002 T.I.R.4) DO NOT SCALE DRAWING

    DATE CREATED

    MATERIAL

    DESIGNED

    REV DATE DESCRIPTION E.C.O

    00

    1 OF 1

    \\Fileserver\Spartek\TechFiles\10011790

    17

    Gamma Calibrator Assembly Sheet

    B

    09-Jul-200709-Jul-2007

    steveg

    SIDE VIEW

    1-3/8" GAMMA TOOL

    1-3/8" CASING COLLAR LOCATOR

    END VIEW

    TOP VIEWALIGN END OF CALIBRATOR STICKWITH END OF GAMMA TOOL HOUSING(AS ENGRAVED ON THE STICK)

    GAMMA RAY CALIBRATORITEM# 10013605

    VELCRO STRAP (2)

    1" X 6" SCINTALATION CRYSTAL

    GAMMA TOOL CALIBRATION -MEMORY MODE ONLY -

    Gamma Calibration Steps:NOTE 1 -If Calibrator on and Calibrator off values are known and a calibration file needs to be created follow from step 14.NOTE 2 -If a calibration file exists, but is not setup just choose Import Cal from File in the Gamma ray calibration pane.

    1. Connect the Memory Controller to the Gamma ray module.2. Connect the Memory Controller to the interface box, and interface box to the computer system.3. Apply 12 volts power to the interface box to power the box and Memory tools.4. In SparWorks Memory Production Logging pane select "Auto Program Tool" to build the program and "ACT" for the tool string.5. Once the tool has finished programming, wrap the Gamma ray calibrator around the Gamma ray tool according to the diagram.6. Remove the power from the interface box, then change the toggle switch to set memory tool in the record mode.7. Allow the tool to record data with the "Calibrator on" for approximately 1 minute then remove the calibrator.8. Record "Calibrator off" data for about 1 minute.9. Remove power from the interface box, then change the toggle switch back to the program/download mode position.10. Download the Memory Controller, then select Merge Data.11. Select the log run, then Import the MPLTXXX file containing Gamma ray calibrator responses.12. View Gamma ray curve data and observe the counts/second values for Calibrator on and Calibrator off (record values on paper using pen or pencil).13. Close Merge Data window, and select Setup from the Memory Production Logging pane.14. Choose Calibrations, then highlight Gamma ray.15. Choose Gamma ray as calibration method.16. Enter the Calibrator on, and Calibrator off average Gamma ray counts/second values.17. Enter the Calibrator Value (gAPI) of 14818. Choose Calculate, then Export Cal to File.19. Choose Save, then Save.20. Calibration should be complete.

    Calibration - Gamma Ray Table (Figure 1)