Fuxin CZ Building System Materials

4
Issued: 13/11/2015 PAGE 1 CZ BUILDINGS SYSTEM STANDARD I. STANDARD MATERIALS 1. COLD-FORMED SECTIONS TYPE SECTIONS ORDER LENGTH USAGE SPECIFICATION GALVANIZED 150Z12 COIL 1.20mm x 295mm W Purlins, Girts & Eave @Bay spacing = 5m or less JIS G3302 SGC490 Z180 (For Galvanized) Fy = 36.5 kN/cm² Fu = 49.0 kN/cm² 150C15 COIL 1.50mm x 295mm W End Wall Rafters, End Wall Columns, Opening Frames (Door Header/ Door Jamb) Rigid Frames 150C20 COIL 2.00mm x 295mm W 150C25 COIL 2.50mm x 295mm W 150C30 COIL 3.00mm x 295mm W 200C15 COIL 1.50mm x 365mm W 200C20 COIL 2.00mm x 365mm W 200C25 COIL 2.50mm x 365mm W 200C30 COIL 3.00mm x 365mm W 250C15 COIL 1.50mm x 425mm W 250C20 COIL 2.00mm x 425mm W 250C25 COIL 2.50mm x 425mm W 250C30 COIL 3.00mm x 425mm W 75C20 COIL 2.00mm x 170mm W Slide Door Guide 2. HOT-ROLLED SECTIONS TYPE ORDER SIZE USAGE SPECIFICATION ANGLES 100mm x 100mm x 8mm x 12m Flange Bracing, X Bracing and Open Web Joist Member JIS-G3101 SS400 Fy = 23.5 kN/cm² Fu = 40.0 kN/cm² 100mm x 100mm x 10mm x 12m 3. SHEETING PANEL TYPE THICKNESS ORDER SIZE USAGE SPECIFICATION I-TRIM 1000-7 (7- Rib) 0.40mm 0.45mm 0.50mm Coil 1200mm W Sheeting Panels for Walls, Liners & Partitions, Eave Extensions, Roof Monitors, Canopies, Soffit & Sliding Door Liners AS 1397 G300 Coating AZ100 Fy = 30.0 kN/cm² I-TRIM 1000-5 (Hi-Rib) 0.40mm 0.45mm 0.50mm Coil 1200mm W Sheeting Panels for Roof & Walls I-CAP 980 (5-Rib) 0.40mm 0.45mm 0.50mm Coil 1200mm W Sheeting Panel for Roof, available with PU20mm, PU30mm & PU40mm MTL-070715-00

description

Material Specification for Fuxin Steel Buildings CZ product

Transcript of Fuxin CZ Building System Materials

Page 1: Fuxin CZ Building System Materials

Issued: 13/11/2015 PAGE 1

CZ BUILDINGS SYSTEM STANDARD

I. STANDARD MATERIALS 1. COLD-FORMED SECTIONS

TYPE SECTIONS ORDER LENGTH USAGE SPECIFICATION

GA

LVA

NIZ

ED

150Z12 COIL 1.20mm x 295mm W Purlins, Girts & Eave

@Bay spacing = 5m or less

JIS G3302 SGC490 Z180

(For Galvanized) Fy = 36.5 kN/cm² Fu = 49.0 kN/cm²

150C15 COIL 1.50mm x 295mm W

End Wall Rafters, End Wall Columns, Opening Frames (Door Header/ Door Jamb)

Rigid Frames

150C20 COIL 2.00mm x 295mm W

150C25 COIL 2.50mm x 295mm W

150C30 COIL 3.00mm x 295mm W

200C15 COIL 1.50mm x 365mm W

200C20 COIL 2.00mm x 365mm W

200C25 COIL 2.50mm x 365mm W

200C30 COIL 3.00mm x 365mm W

250C15 COIL 1.50mm x 425mm W

250C20 COIL 2.00mm x 425mm W

250C25 COIL 2.50mm x 425mm W

250C30 COIL 3.00mm x 425mm W

75C20 COIL 2.00mm x 170mm W Slide Door Guide

2. HOT-ROLLED SECTIONS

TYPE ORDER SIZE USAGE SPECIFICATION

ANGLES

100mm x 100mm x 8mm x 12m Flange Bracing, X Bracing and Open Web

Joist Member

JIS-G3101 SS400 Fy = 23.5 kN/cm² Fu = 40.0 kN/cm²

100mm x 100mm x 10mm x 12m

3. SHEETING

PANEL TYPE THICKNESS ORDER SIZE USAGE SPECIFICATION

I-TRIM 1000-7 (7-Rib)

0.40mm 0.45mm 0.50mm

Coil 1200mm W

Sheeting Panels for Walls, Liners & Partitions, Eave Extensions, Roof Monitors, Canopies, Soffit & Sliding Door Liners

AS 1397 G300

Coating AZ100 Fy = 30.0 kN/cm²

I-TRIM 1000-5 (Hi-Rib)

0.40mm 0.45mm 0.50mm

Coil 1200mm W

Sheeting Panels for Roof & Walls

I-CAP 980 (5-Rib) 0.40mm 0.45mm 0.50mm

Coil 1200mm W

Sheeting Panel for Roof, available with PU20mm, PU30mm & PU40mm

MTL-070715-00

Page 2: Fuxin CZ Building System Materials

Issued: 13/11/2015 PAGE 2

4. SKYLIGHT PANELS

PANEL TYPE THICKNESS ORDER LENGTH USAGE SPECIFICATION SKYLITE1000 (5-Rib) SKYLITE1000 (7-Rib) 1.2mm 5500mm

Translucent Panels for Roof, Walls

SKYLITE980 (5-Rib)

5. TRIMS

TYPE COLOR MAXIMUM ORDER SIZE SPECIFICATION

Trims & Flashing All Standard Colors COIL 0.5mm T x 600mm W AS 1397 G300 Coating AZ100

Fy = 30.0 kN/cm²

Gutters Valley Gutters

All Standard Colors COIL 0.5mm T x 1210mm W AS 1397 G300 Coating AZ100

Fy = 30.0 kN/cm²

Stainless Steel COIL 0.6mm T x 1219mm W Stainless Steel SS304

6. INSULATION

TYPE ORDER SIZE USAGE SPECIFICATION

Air Bubble 3mm x 1240mm x 100m L Insulation in Roof & Walls (Single Skin)

Polyurethane Foam (PU) 20mm T 30mm T 40mm T

Insulation Attached in I-CAP 980 Double Skin with Aluminum Foil

Or Back Panel

7. RODS

ROD DIAMETER ORDER LENGTH USAGE SPECIFICATION

12mm 1.5m Sag Rods ASTM A36M

Fy = 25.0 kN/cm² Fu = 40.0 kN/cm²

8. BRACING STRAP

STRAP WIDTH THICKNESS USAGE SPECIFICATION

30mm 1.0 mm Bracing in Roof and Walls JIS G3302

SGC490 Z180

9. ANCHOR BOLTS

DIAMETER (mm) ORDER LENGTH USAGE SPECIFICATION

M16 400mm Anchor bolts for Endwall & Partition

Column Bases

ASTM A36M Fy = 25.0 kN/cm² Fu = 40.0 kN/cm²

Page 3: Fuxin CZ Building System Materials

Issued: 13/11/2015 PAGE 3

10. BOLTS

DIAMETER (mm) ORDER LENGTH USAGE SPECIFICATION

M12 30mm Secondary Connections

Purlins & Girts

DIN 558 GRADE 4.8 Fy = 32.0 kN/cm² Fu = 40.0 kN/cm²

M12 35mm Eave Strut

Frame Connections ASTM A325M

Fy = 56.0 kN/cm² Fu = 72.5 kN/cm² M16 50mm

Connections of Primary Sections Other Moment Connections

11. NUTS

NUT DIAMETER (mm) USAGE SPECIFICATION

M12 Secondary Connections - Machine Bolts DIN 934 Class 5

M16 For Anchor Bolts DIN 934 Class 5

Electro Galvanized Hexagon Nuts

M12 High Strength Nut for

Main Connections

DIN 934 Class8 HDG

M16 ASTM A563M

HDG Hexagonal Nut

12. WASHERS

WASHER DIAMETER (mm) USAGE SPECIFICATION

M16 For Anchor Bolts DIN 125 Type A Flat Mild Elect.

Galvanized

M12 For High Strength Bolt of Main Connections

ASTM F436 Type 1 Round Hard M16

13. SCREWS & RIVETS

SIZE USAGE

SPECIFICATION Wall Panel Roof Panel

SDS 5.5x25

I-Trim 1000-5 I-Trim 1000-7 I-Span 1000-9 I-Cap (No PU)

Angle Screw*; Gutter Strap

- SPEDEC SD5 T15-5.5 x 25mm

SDS 5.5x57

I-Trim 1000-5 I-Trim 1000-7 I-Span 1000-9 I-Cap (No PU)

I-Cap (PU 30mm)

I-Trim 1000-5 I-Trim 1000-7 I-Span 1000-9 I-Cap (No PU)

SPEDEC SD5 T15-5.5x57mm

SDS 5.5x62 I-Cap (PU 40mm) - SPEDEC SD5 T15-5.5 x 62mm

SDS 5.5x77 - I-Cap (PU 20mm) I-Cap (PU 30mm)

SPEDEC SD5 T15-5.5 x 77mm

SDS 5.5x107 - I-Cap (PU 40mm) SPEDEC SD5 T15-5.5 x 107mm

FH 4x25 Inside Trim to Panel -

4.8x20 Outside Trim to Panel SPEDEC SD5 T15-4.8 x 20mm

Pop Rivets Laps of Trims. Gutter, Downspouts, Gutter End Closure,

Gutter-Downspout Connection SD 46BS

* Angle use at Eave, Gable, Canopy (Except base angle that use expansion bolt)

Page 4: Fuxin CZ Building System Materials

Issued: 13/11/2015 PAGE 4

II. BUILDING STANDARD SIZES 1. PRIMARY FRAMES

SIZE HEIGHT (mm)

WIDTH (mm)

ENDWALL BAY SPACING

LENGTH (mm)

REGID FRAME (Column/Rafter)

ENDWALL (Column/Rafter)

S1

3000

10000 1@3m; 1@4m; 1@3m 16000 - 150000

(Accumulated by 1000 mm)

150D20 150C15

4000 200D20 200C15

5000 200D30 200C20

S2

4000

12000 3@4m 16000 - 150000

(Accumulated by 1000 mm)

200D20 200C15

5000 200D30 200C20

6000 250D30 250C20

S3

4000

15000 3@5m 16000 - 150000

(Accumulated by 1000 mm)

200D25 200C20

5000 250D25 250C20

6000 250D30 250C25

S4 5000

18000 1@4m; 2@5m; 1@4m 16000 - 150000

(Accumulated by 1000 mm)

250D30 250C20 6000 300D30 300C25 7000 300D30 300C25

Note: “D” stands for “Double C Frame”. It is made by connecting 2 “C Frame” back to back with 8mm Gap.

2. SECONDARY FRAMES

SIZE GIRTS PURLINS EAVES USAGE

S1

150Z12 150Z12 150Z12 SideWall, EndWall, Roof S2

S3

S4

III. DESIGN SPECIFICATION

DESIGN CODE DESIGN LOAD

Dead Load (DL) Live Load (LL) Wind Load (WL)

MBMA 06 0.1 kN/m2 0.32 kN/m2 32 m/s

Note: “MBMA 06” stands for Metal Building Systems Manual 2006