Red Spot Miniature Fuse Holders
RSM Red Spot Fuse Holders
Rating Type Colour Connection Recommended Associated fuse linkA max. cable size
32A RSM32H Black Front wired 10mm2 NIT2-32 (415V, 550V)
63A RSM63H Black Front wired 25mm2 TIA / TIS
100A RSM100H Black Front wired 50mm2 TIS / OS
160A RSM160H Black Front wired 95mm2 TCP / TFP
Accessories
Pad-lockable Inserts
RS20LOCK Suits RSM32
RS32LOCK Suits RSM63
RS63LOCK Suits RSM100
RS100LOCK Suits RSM160
DIN Rail Adaptor
RS20A Suits RSM32
White Fuse Fittings (to match size of RSM black fuse fittings)
Type Associated Black Fuse Fitting Copper Link Type Number
RS20HWH RSM32H RS20CLINK
RS32HWH RSM63H RS32CLINK
RS63HWH RSM100H RS63CLINK
Copper Link Ratings
RS20CLINK=32A RS32CLINK=63A RS63CLINK=100A RS100CLINK=200A
RSM
FUSE
HOL
DERS
& A
CCES
SORI
ES
World leading Red Spot quality at the right price Smallest BS88 bolt-in fuse holders available Silver plated as standard Fully shrouded for personal safety Insulating sleeves supplied with front wired versions for extra protection Suitable as current limiters when fitted with fuse links
4
Panel Drilling Dimensions (viewed from front of panel)
32A
Rating Amp A B C H J X Y Z
32 27 29 55 15 16 60 6.6 37 mm
63 32 103 70 15 22 7.0 5.6 49 mm
100 35 110 75 15 24 9.5 5.6 54 mm
160 51 140 100 15 28 14 7.2 74 mm
32, 63, 100 & 160 amp Front Connected
RSM FUSE HOLDERS & ACCESSORIES
160A
RSM32H RSM63H RSM100H RSM160H
63A 100A
N P U V
mm 6.4 3.2 9.5 11.1
RSM Dimensions
5
Red Spot Fuse Fittings
Cut-away view of 63 amp frontconnected contact assembly
Type Numbers
Alternative type of connection
Rating amp Front Back Front/Back Back Wired
20 RS20H* RS20P RS20PH RS20BW
32 RS32H RS32P RS32PH RS32BW
63 RS63H RS63P RS63PH RS63BW
100 RS100H RS100P RS100PH RS100BW
200 RS200H RS200P RS200PH
400 RS400H RS400P RS400PH
Illustrations & dimensions shown on pages 8-11 * For Din Rail Mounting order DIN Rail Adaptor Part No: RS20A
Recommended Maximum Cable Sizes
Rating amp H and PH types BW types
20 10mm2 10mm2
32 25mm2 16mm2
63 50mm2 35mm2
100 95mm2 70mm2
200 120mm2
400 240mm2
Safety Features
Full Shrouding for personnelsafety and complete compliancewith the direct contact electricshock requirements.
Insulating sleeves are fitted tofront connected fuse bases toprovide increased protection atthe cable entry point.
Separate base contact insulatingshrouds of great strength andflexibility ensure that no livemetal is dangerously exposedwhen the fuse carrier is removed.
Anti-vibration features protectagainst release of a fuse-carrierdue to vibration in service. In the400 amp size this includes a safetycatch which automatically locks onthe insertion of the fuse carrier.
Fuse fittings to AS2005.21.2 1990, BS88: Part 2: 1988, 660 volts AC/DC.Approved by leading authorities and used in equipment approved by Lloyds.
REDS
POT F
USE H
OLDE
RS &
ACC
ESSO
RIES
6
Method of Cabling
Front connected fuse fittings1. Remove red nylon insulating shroud to release cable sleeve.2. Remove cable sleeve.3. Fit cable sleeve over cable.4. Fit conductor into fuse base terminal and tighten cable clamping screw to
secure. If flexible cables are used, their relatively fine strands may be givenincreased protection by the use of thin wall copper ferrules over the conductor.The following should be taken into account:a) The inside diameter of the thin wall copper ferrule should match that of the
bared conductor end as closely as possible.b) The length of the thin wall copper ferrule should match that of the tunnel in
the fuse base terminal.c) The wall thickness of the ferrule should be thin enough for the ferrule to be
compressed by the tightening of the cable clamping screw. The flexibleconductors will then be consolidated within the deformed ferrule.
5. Replace red nylon shroud taking care that it holds the cable sleeve in positionby locating the shroud in the groove in the sleeves.
Front connected 63 amp fuse fitting
Application Data
Extended range of Type T to BS.88:Part 2: AS2005.21.2 for motor circuit protection (660V AC)
Fuse Fitting Rating Type T to BS.88:Part 2 & AS2005.21.2 List No. Current Rating Rating forAmp 550/660V 415V AC 550/660V 415V AC Amp Motor Starting Amp
NIT2-20ANIT20M25
20 2520(550 volts a.c.)
NIT2L-20L NIT20M3220 32(415 volts a.c.)
TIA32M35 TIA32M35L 32 35
32 TIA2-32A TIA2L-32LTIA32M50 TIA32M40L 32 40TIA32M50 TIA32M50L 32 50TIA32M63 TIA32M63L 32 63
63TIA2-32A TIA2L-32L TIS63M80 63 80TIS35-63A TIS35L-63L TIS63M100 63 100
TIA2-32A TIA2L-32L TCP100M125 100 125100 TIS35-63A TIS35L-63L TCP100M160 100 160
TCP80 & 100A TCP80L&100L TCP100M200 100 200
TBC2-63ATC80L & 100L TF200M250 200 250200 TC80 & 100ATF125L-200L TF200M315 200 315TF125-200A
TBC2-63A#TC80 & 100#
TC80L & 100L#400
TF125-200#TKF250L&315L# TM400M450 400 450TKF250 & 315#TM355L&400LTKM250 & 315A
TM355 & 400A
Adaptor plate required Type A 5BB9306-010 # Adaptor plate required Type B 5BB9307-010
HRC Fuse Links Accomodated
REDSPOT FUSE HOLDERS & ACCESSORI ES
7
REDS
POT F
USE H
OLDE
RS &
ACC
ESSO
RIES
Dimensions
A B C1 C2 D E F G H J K L X Y Y2 Z
mm 27.0 79.0 54.0 55.0 63 58.8 M6 13.5 15.0 16 10.10 29 6.0 5.6 6.6 37
20A Red Spot Fuse Fittings
Panel Drilling Dimensions (viewed from front of panel)
Front Connected Front/Back Connected Back Connected Surface
8
Dimensions
N P Q R S T U V W
mm 6.4 3.2 36.5 41.3 52.4 51.6 9.5 11.1 46.8
32, 63 & 100 amp Red Spot Fuse Fittings
Rating Amp A B C D E F G H J K L X Y Z
32 32 103 70 81.0 73 M6 17.5 15 22 15 29 6.2 5.6 49 mm
63 35 110 75 84.0 78 M8 17.5 15 24 16 29 9.5 5.6 54 mm
100 51 140 100 87 94 M10 22 15 28 23 32 14 7.2 74 mm
Panel Drilling Dimensions (viewed from front of panel)
Front Connected Front/Back Connected Back Connected Surface
REDSPOT FUSE HOLDERS & ACCESSORI ES
9
REDS
POT F
USE H
OLDE
RS &
ACC
ESSO
RIES
Dimensions
200 amp Red Spot Fuse Fittings
Rating Amp A B C D E F G H J K L M X Y Z
200 70 216 136.5 95 171.5 M12 25 22 32 22 32 100.0 16 9.5 84 mm
400 98 254.0 192 114 140 M16 32 32 36.5 57 38 151 21 32 130 mm
400 amp Red Spot Fuse Fittings
Panel Drilling Dimensions (viewed from front of panel)
N P Q
mm 19.1 28.6 85.7
P Q
mm 27.0 69.9
Front Connected Front/Back Connected Back Connected Surface
RS200H RS200P & RS200PHRS400H RS400P & RS400PH
10
Dimensions
Red Spot Fuse Fittings Back Wired Panel Mounted
Type Rating Amp A B C D E F G H J K L X Max. CableAll dimensions in mm DIA Size mm2
RS20BW 20 27 80 54 6 30 30 8 To suit M5 37 5.3 10
RS32BW 32 32 103 70 6 40 40 3.2 6.4 8 M5 49 5.4 16
RS63BW 63 35 110 75 6 40 46 3.2 6.4 8 M5 54 8.7 35
RS100BW 100 51 140 100 7 52.6 52.6 11 9.5 16 M6 74 12.7 50
REDSPOT FUSE HOLDERS & ACCESSORI ES
11
REDS
POT F
USE H
OLDE
RS &
ACC
ESSO
RIES
Accessories
Padlockable Insert
When ordering please quotethe following number:
Current Rating Amp Type *
20 RS20Lock
32 RS32Lock
63 RS63Lock
100 RS100Lock
Because of the variety of suitable locks available,and customers individual preferences, thesedevices are supplied without padlocks.
DIN Rail Adaptor
RS20A for the RS20 range of fittings
Bolted Neutral Links
Fitting Type Model
20 RS20CLINK
32 RS32CLINK
63 RS63CLINK
100 RS100CLINK
Adaptors to fit Semiconductor FuseLinks into Red Spot Fuse Fittings
Type To fit fuses Fuse Fitting
GSA-1 GSA5 to GSA20 RS32
GSA-2 GSA25 to GSA75 RS100
GSB-2 GSB25 to GSB75 RS100
GSGB16 to GSGB63 RS100
Adaptors to fit small Fuse Linksinto larger Red Spot Fuse Fittings
Type To fit fuses Fuse Fitting
AA TIA, TIS RS100
BA TBC, TC, TF, TKF RS400
12
Safeclip Fuse Fittings
Features & Benefits
NEW easy to remove fuse carrier. Self cleaning, self aligning base contacts. Fuse carriers moulded from tough flame retardant material. No screws or tools required to fit fuse. Made from flame retardant thermoplastic or phenolic. Integral DIN rail mounting feature. Full shrouding and complete compliance with the direct contact
electric shock requirements.
Rating Amp Type of Connection List Number Colour Associated HRC Fuse Lines
20 Front SC20H Black, WhiteNS2 20NS20M25 & 32
Front SC32H Black, White
Back SC32P Black, WhiteNS2 32
Busbar/Front SC32BH BlackNS20M25 & 32
Busbar/Front SC32BHA+ Black
Back Wired SC32BW Black
Front SC63H-D Black, White NS2 32*
63 Back SC63P Black ES40, 50 & 63
Busbar/Front SC63BH Black ES63M80
* SCA63NS carrier requiredNote: All fuse fittings provided with DIN rail facility except: SC32 & 63BH; SC63P+ Long stud version
Accessories
Rating List Number
Adaptor carrier for fitting Type NS 32 SCA63NSfuse links into SC63 fuse holder
Copper links 20/32 SC20/32LINK
63 ESCLINK
Recommended Maximum Cable Sizes
Rating amp H and PH types BW types
20 16mm2
32 16mm2 16mm2
63 25mm2
20, 32 & 63A415/550V AC.
Complying fully withAS2005.29 1990,BS88 : Part 6 : 1988.
SAFECLIP FUSE HOLDERS & ACCESSORI ES
13
SAFE
CLIP
FUSE
HOL
DERS
& A
CCES
SORI
ES
SAFECLIP Fuse Fitting Dimensions
Front Connected
Back Connected
Rating A B C D E F G H J Kamp
20 & 32 26.5 75.5 54 16 4 2 6 M5
63 30 96 58 24 5 6 8 5 8 M5
Rating A B C D E F G H J K Lamp
32 26.5 75.5 54 16 5 40 29 M6 2 M5 14
63 30 96 53 16 5 51 32 M8 5 M5 17
20A & 32A 63A 20 to 63A 20 to 63A
Panel drilling viewedfrom front of panel
20 & 32A; 63A
63A
Panel drilling viewed from front of panel
32A
14
SAFECLIP Fuse Fitting Dimensions
Busbar/Front Connected
Back Wired
Rating A B C D E F G H J K L M Namp
32 25 81 47 18 5 1 12 29 6 2 M5 M5 4
32/A* 26.5 75.5 54 16 1 40 29 6 2 M6 M5 2
63 30 96 53 20 5 1 12 33 8 6 M6 M5 6
* Long stud version
Panel drilling viewed from front of panel32 & 63 amp
32 amp
SAFECLIP FUSE HOLDERS & ACCESSORI ES
15
MOD
ULAR
FUSE
HOL
DERS
Modular Fuse Holders
Modular Fuse Holder Holders
Amp List No. Type Fuse Size Fuse Ratings Type
FMC101 1 Pole, Compact
32 FMC101S 1 Pole, Compact + Indication10 x 38 0.5A - 32A 10G
FMC103 3 Pole
CMS141 1 Pole
50CMS141S 1 Pole + Indication
14 x 58 2A - 50A 14GCMS141M 1 Pole + Microswitch
CMS141SM 1 Pole + Indication + Microswitch
CMS221 1 Pole
125CMS221S 1 Pole + Indication
22 x 58 4A - 125A 22GCMS221M 1 Pole + Microswitch
CMS221SM 1 Pole + Indication + Microswitch
Indication refers to fuse blown indication (neon globe built into fuseholder).Microswitch = 3 pin (NC, NO, C) indicates no fuse, holder open, blown fuse (striker fuses only).
Accessories
List No. Type
FMP3 Connector pin for multi-pole FMC type holders
MPOLE14 Multi-pole kit for CMS141 connects up to 10 poles
MPOLE22 Multi-pole kit for CMS221 connects up to 10 poles
Available in 32A, 50A & 125A ratings. DIN rail mountable. Made from highly temperature resistant polyamide material. Available with integral neon fuse blown indicators. All models (except FMC) are sealable in the closed position. 50A & 125A versions padlockable open for maintenance safety. 50A & 125A versions available with a microswitch for remote indication. Conform to IEC269-2.
CMS221
CMS221M
FMC101
16
Maximum Fuse Recommended TorqueRating Ulmp Fuse Current Operating Current (A) Copper Wire MaxiUN(V) (kV) Rating IN(A) gG aM gRC UR SIze (mm2) N.m.
0.25 0.25 0.25
0.5
1
2
4
6
8
CMS141 690 8 10 10 10 3.5
12 12 12
16 16 16 2.5
20 20 20 2.5
25 25 20 4
32 32 25 6
40 40 40 30 30 6
50 50 50 38 35 10
1 1
2
4
6
8
10
12
16
CMS221 690 8 20 20 20 4 4
25 25 25 6
32 32 42 10
40 40 40 6
50 50 50 10
63 51 63 16
80 64 60 25
100 100 74 70 35
125 100 35
MODULAR FUSE HOLDERS
Technical Features CMS
FMC101S
CMS141M
CMS221
17
Modular Fuse Holders and Fuse Links
A B C D E F
32 Amp 59 78 45 17.5 78 43
50 Amp 76.5 100.5 45 26.5 107 50.5
125 Amp 76.5 103 45 35 126.5 50.5
The fuse holders can be fullyrated provided that the fuse linkdoes not exceed the holders ratedpower acceptance:
FMC101 3W power acceptance
CMS141 4.7W power acceptance
CMS221 9.0W power acceptance
Maximum cable size for thefuse holders:
10mm compact holder cable up to 25mm2
14mm holder cable up to 35mm2
22mm holder cable up to 35mm2
De-rating for mounting inclose proximity is as follows:
up to 3 poles Derating factor = 1
between 4-6 poles Derating factor = 0.8
between 7-9 poles Derating factor = 0.7
above 10 poles Derating factor = 0.6
Dimensions (mm)
Cross Section of Typical Modular Fuse Base
Voltage limits for blown fuseindicator operation:
Neon just glowing 65vac/60vdc
Neon glowing strong 100vac/100vdc
MOD
ULAR
FUSE
HOL
DERS
Material
Base: PolyamideHandle: Thermal PolyesterSelf extinguishableContacts: Silver PlatedProtection Index IP20Live parts are inaccessible
1 Base2 Contact3 Slide4 Handle5 Fuse-link6 Bolt
18
DIN Fuse Bases & Accessories
DIN FUSE BASES & ACCESSORIES Style Legend OB Open baseFS Fully shrouded IP20OB2D Open base plus 2 dividers
Spares and Accessories
Size DividersTerminal Fuse Base DINShrouds Covers Separators Rail Clip
00 NH00GDIV NH00TS NH00FC NH00DRC
1 NH1GDIV NH1TS NH1FC NH1SEP NH123DRC
2 NH1GDIV NH2TS NH1FC NH1SEP NH123DRC
3 NH3GDIV NH3TS NH3FC NH3SEP NH123DRC
Extractor Handle
Size Rating Amp No of poles Style Type No
1 OB NH00GBASE
00 1601 FS K-NH00GSHB
3 OB2D K-NH00G3PB2D
3 FS NH003PSHB
1 OB NH1GBASE
1 2501 FS K-NH1GSHB
3 OB2D K-NH1G3PB2D
3 FS K-NH1G3PSHB
1 OB NH2GBASE
2 4001 FS K-NH2GSHB
3 OB2D K-NH2G3PB2D
3 FS K-NH2G3PSHB
1 OB NH3GBASE
3 6301 FS K-NH3GSHB
3 OB2D K-NH3G3PB2D
3 FS K-NH3G3PSHB
4 1250 1 OB NH4BASE
1 Terminal Shields2 NH Fuse Base3 Separator4 Insulating Dividers5 Fuse Shield6 DIN Rail Clip (optional)
Complies withDIN43620IEC269-2-1690VAC
1
2
3
5
4
6
NH-HANDLE Sizes 000 4
19
NH Base Dimensions
DIN
FUSE
BAS
ES &
ACC
ESSO
RIES
DimensionsSize 00
DimensionsSizes 1, 2, 3 & 4
A B C D E F G H I J K L M N O P Q R
32 20 117 100 8 2 14 25 145 21,5 8 56 52 85 84 34 1 104
A B C D E F G H I J K L M N O P Q R S
NH1- 60 32 209 176 10,5 30 20,5 25 250 35 M10 81 71 122,5 146 65,5 125,5 191 256,5
NH2- 60 35 225 201 10,5 30 20,5 25 250 35 M10 81 89 122,5 146 65,5 125,5 191 256,5
NH3- 60 40 241 210 10,5 30 20,5 25 270 35 M12 81 103 142,5 146 81,5 141,5 223 304,5
NH4- 80 45 312 262 11 45 30 45 M16 111 145 192
G
N
M
L O I
K
J P
R
C
QA
B
F F
EHD
A
B
HDCG
E
F
LI
K
J
M
N
O
P
Q
R
S
20
DIN Disconnects (horizontal)
IEC 947-3 EN 60947 VDE 0660
DIN Fuse Switch-Disconnectors 690V
Sizes 00 and 1 can be interlocked and sealed. Single pole versions available. DIN fuse switch-disconnectors for 1250 A and 1600 A available in single pole
and three pole versions for size 4a fuse links (800 1600A). Details on request. Type DIND00BB (00/160A) for direct mounting on 60mm busbar systems. Optimal protection against accidental contact and over reaching. High short-circuit making capacity and rated breaking capacity provided by
semi-independent manual operation of contacts.
Type Rating Poles Connection
DIND003S 160 A 3 STUD
DIND00BB 160 A 3 BUSBAR/STUD
DIND013S 250 A 3 STUD
DIND023S 400 A 3 STUD
DIND033S 630 A 3 STUD
1 Protection against overreaching at the top (GO) preventsaccidental contact with the upper terminal area.
2 Multifunctional front cover.
3 Optional interlocking and sealing facility.
4 Empty space for company logo.
5 Empty space, e.g. for labelling of circuits.
6 Lock slide for test holes.
7 Test holes to contact blades.
8 Disconnector casing with universal connection.
9 Protection against overreaching at the bottom (GU)prevents accidental contact with the upper terminal area.
10 Divided shrouding with integrated protectionagainst overreaching.
11 Busbar adapter for 60mm busbar system.
DIN FUSE DISCONNE CTS HORIZONTAL
21
Line and LoadShroud Sets
Cable Clamp Sets
For Disconnector Type Terminal RangeSize Min. - Max. mm
00 CLAMP00 1.5 - 70 *
1 CLAMP1 25 - 150 *
2 CLAMP2 25 - 240 *
* Clamp Terminals for Copperand Aluminium Conductors
Accessories for DIN Disconnectors Series 9
Busbar AdaptorsFor 60mm busbar system. Sizes 1 & 2
Electronic Fuse MonitoringDevice: EMDS42TA1
Size Type
1 BBA01
2 BBA02
Require Clamps
Direct Busbar Mounting160A Disconnector
Type DIND00BB (00/160A) for directmounting on 60mm busbar systems.
To fit: 60mm busbar systems(centre to centre)
30mm wide busbar
5-10mm thick busbar
DIN
FUSE
DIS
CONN
ECTS
H
ORIZ
ONTA
L
Size Side Type
00Top GO-LTL00-3
Bottom GU-LTL00-3
1Top GO-LTL1-3
Bottom GU-LTL1-3
2Top GO-LTL2-3
Bottom GU-LTL2-3
22
Technical Data
NH Fuse Switch-Disconnector Series 9 Size 00 Size 1 Size 2 Size 3
Rated operational current le A 160 250 400 630
Thermal current with solid links A 210 325 520 820
Thermal current with fuse-links A 185 290 460 725
Rated voltage Ue V 690 690 690 690
Rated insulation voltage Ui V 750 750 750 750
Rated frequency Hz 40 60
Test voltage kVeff 8
Maximum DIN NH gG fuse link rating A 160 250 400 630
Maximum DIN semiconductor fuse rating Call ALSTOM for advice
Insulation group ll to VDE 0110 CTI 400 - 600
Rated making and breaking capacity
at ~400V; cos = 0,35 A 1250 2500 3800 3800
at ~500V; cos = 0,35 A 800 1500 2400 3800
at ~690V; cos = 0,35 A 480 1000 1600 2000
at ...220V; L/R = 15ms A 240 375 600 950
Short-time withstand current 1s kAeff 15 27 32 38
Short-circuit rating with protection by means of fuses kAeff 120 120 120 120
Short-circuit making capacity with solid links (peak value) k 24 36 48 70
Mechanical lifespan (operations) >1000
Permissable ambient temperature C -25 bis + 55
Climatic proofing DIN 50016 FW24 (23C/83% - 40C/92%)DIN 50017 SFW - 30 cycles
DIN 50018 SFW 0,2 S - 2 cycles
Shock-proof for use on railways according to VDE 0115 2g / 5g
Altitude (without restriction) 3000m
Seismic withstand capability to DIN 40046/8 0,8g / 16 Hz - 35 Hz
Rated heat dissipation of contacts 3x2.3W 3x4.3W 3x9.0W 3x17.3W
DIN FUSE DISCONNE CTS HORIZONTAL
23
Type A B C D E F R G L N O S
DIND003 105.5 149 83.5 151 43 25 198 79 120 17 M8 33
DIND013 184 230 113 220 64 43.75 295 114 177 24.5 M10 58
DIND023 210 256 127 244 78.5 69.75 332 128 205 24.5 M10 66
DIND033 254 270 142 244 93.5 80 345 135 219.5 30.5 M10 82
* Dimension C1: 132mm with electronic fuse monitoring device fitted
Dimensions
Fixing Dimensions
Size 00 Size 1 Size 2 Size 3
DIN
FUSE
DIS
CONN
ECTS
H
ORIZ
ONTA
L
24
DIN Disconnects (vertical)
Strip Fuseaways sizes 1 - 3for Flush and Surface Mountingby JEAN MLLER 1-pole switchable
DIN Size Rated Current Type Weight kg
1 250 SL1-3x 5,8
2 400 SL2-3x 6,1
3 630 SL3-3x 6,8
3-pole switchable
DIN Size Rated Current Type Weight kg
1 250 SL1-3x3 5,8
2 400 SL2-3x3 6,1
3 630 SL3-3x3 7,5
Specials available on request (sizes 00/160A - 4/1250A & 1800A size 3 isolators, pictured)
Connection possibilities
Screw Connection Standard design Size1: M10 Size 2 and 3: M12
New Delta Contact
4 separately spring loaded contact lines forlow contact resistances.
50% greater surface area for low contacttemperatures.
Optimum arc control while switching loads. Connection to short circuit (50kA) possible without
switching aids. High dynamic strength during switching operations.
Special strip features
Suitable for busbar mounting with 185mm spacing between busbar centres. Cable connection at the top or bottom can be achieved by simply turning
the base moulding of the contacts upside down, while the panel apertureremains unchanged.
Removable fuse carrier allows easy mounting. Equal mounting conditions allow combination with size 00 strip fuseaways. Complete protection against electric shock in on- and off-position in
accordance with German accident prevention legislation (VBG4). Connection of conductors by means of cable lugs or direct connecting terminals. The hinged cover holding the fuse-link is parked in the off-position this means
visible disconnection. Latch-in elements for fixing to the panel. All 3 phases of the 3-pole switchable strip fusaways are switched simultaneously. Hinged cover of 3-pole switchable version can be barred and locked.
NH Load-disconnect strip fuseaways DIN sizes 1 3 for flush and surface mounting.
DIN FUSE DISCONNE CTS VERTICAL
25
DIN Disconnects (vertical) Dimensions
Dimensions
Accessories
Size 1 Size 2 Size 3
Hinged cover for test purposesMS-SL1 MS-SL2 MS-SL3Suitable for insertion of K-series metering fuses
Hinged cover for earthing purposes1 E-SL123
Hinged cover for piggy-back fuse-links HP-SL123 (suitable for sizes 1, 2 and 3)
Extended shroud in the connection area HA-SL123
1 only for SL1, 2 and 3x3
185
195
SlidingDistanceRest Position: ~335
Operating position ~467
SL... -3x3/...3-pol. switching
195
303
52
154
24
662
14x3
214
50
30
8.5x
1614
100
185
185
150
99.5
SL... -3x/...1-pol. switching
DIN
FUSE
DIS
CONN
ECTS
V
ERTI
CAL
26
Technical Data
NH Load-disconnect Strip Fuseaways for Flush and Surface Mounting DIN Size 1 Size 2 Size 3
Rated current A 250 400 630
Uninterrupted A 325 520 820
Uninterrupted current with solid links A 290 460 725
Rated voltage -V 660 660 660
Rated frequency Hz 40 - 60
Test voltage V 2500
Insulation class to VDE 0110C
which corresponds to degree 3 contaminationin accordance with VDE 0109
Rated making - and breaking capacity to VDE 0660 Part 107
at 400V; cos = 0,35 A 2500 3800 3800
at 500V; cos = 0,35 A 1500 2400 3200
at 690V; cos = 0,35 A 1000 1600 2000
at 220V; L/R = 15ms 375 600 950
Rated short-time with withstand current 1 sec. kA 20 22 25
Short-circuit protection by fuses (current-carrying capacity) kA 120 120 120
Rated conditional short-circuit current with protection by fuses kA 50 50 50
Rated conditional short-circuit current with solid links and protectionkA 36 48 70by fuses (peak value) 500 V; lp = 120 kA
Rated short-circuit making capacity with NH fuse-links kA 105 105 105
Heat dissipation of main current path W 23 49 110
Mechanical lifespan (operations) >1000
Permissable ambient temperature C -25 to + 55
Climatic proofing DIN 50016 FW* 24 (23C/83% 40C/92%)DIN 50017 SFW** 30 cycles
DIN 50018 SFW 0.25; 2 cycles
Shockproof for railway systems to VDE 0115 2g / 5g
Altitude above sea level (without restriction) 3000m
Resistant to earthquakes in accordance with DIN 40046/8 0.8g / 16 Hz - 35 Hz
Tested to VDE 0660 Part 107, VDE 0636 Part 21
* Damp alternating atmosphere ** Damp heat alternating atmosphere
DIN Disconnects (vertical)
DIN FUSE DISCONNE CTS VERTICAL
27
Series 7 Insulated House Service Cutouts
General Features
Thermoplastic moulding giving improved mechanical strength and durability. Easy fuse replacement fuse link self locating in fuse clip. High pressure point contacts wiping action ensures low resistance with silver
plated base contacts. Carrier assembled by means of captive screw. Base moulding in one-piece, increased mechanical strength eliminates tracking. All phase terminals shrouded by fixed shield which is part of moulding. Plain brass terminals with silver plated contact surface for dependable operation. Tin plated fuse clips. Suitable for cable conductors 2.5 sq.mm to 50 sq.mm. Anti-intrusion plate with double hole sealing facility, 100% tamperproof,
allows base to be sealed independently of the handle.
SERI
ES 7
FUSE
HOL
DERS
28
Series 7
Type No. Rating Amps Fuse Link
S71002AFWS 100 Type 2a, RHF30-100
Front Wire Fittings S71002BFW 100 Type 2b, RHLF60-100
S71002BFWAI 100 Type 2b, RHLF60-100
S71002ABWS 100 Type 2a, RHF30-100
Back Wire Fittings S71002BBW 100 Type 2b, RHLF60-100
S71002BBWAI 100 Type 2b, RHLF60-100
AI suffix = fitting fitted with anti-intrusion plate
Dimensions
Front Wire & Back Wire
Type Numbers
SERIES 7 FUSE HO LDERS
Base
Cable entry holes (backwire)
Single Hole Fixing
(1 x 6.35mm diameter hole)
Rear View
83mm
88mm
88mm
42mm
66mm
47mm
29
RSL63
Features and Benefits
Fully Shrouded Ensures complete personnel safety against live metal contact. Insulated Terminal Shrouds Are fitted to front connected fuse bases to
provide increased protection at the cable entry point. Insulated Base Contacts Shrouds Enables an outgoing circuit to be cabled
with complete safety to personnel and with continuity of supply to other circuits. Large Contact Area Solid brass contacts ensure lasting contact pressure. Patented Non-twist Cable Clamping Screws Ensures cable strands are
firmly clamped into position without damaging the cable strands.
Selection Table
TYPE CONNECTION VOLTAGE AC VOLTAGE DC ASSOCIATED T-C HRC FUSE LINK
RSL63H Front 1200 750
RSL 63PH Front/Rear Stud 1200 750TAC 2, 4, 6, 10, 15, 20, 25 & 30
RSL 63P Rear Stud 1200 750TSC 35, 50 & 63
Applications
Short circuit and overload protection when used with T-C HRC fuse links. 1000VAC heating and lighting circuits (mining). Capacitor circuits. A.C. and D.C. motor circuits. Cable overload protection. T-C fuses with minimum fusing currents of
1.5-1-6In will protect cables (PVC insulated copper) when the fuse fitted isequal to or less than the cable rating.
Short circuit cable protection offered to PVC insulated copper cablesi.e. I2t=K2S2, where I = current which causes fuse to operate in 5 seconds,t = 5 seconds, K = 115, S = conductor cross sectional area in mm2.
RSL F
USE H
OLDE
RS
30
Dimensions
RSL FUSE HOLDERS
31
Fuse Link Selection Chart
20
32
63 H
20
32 E
63
100 A A F G G
200
400 B B B B
32
63
100
160 A A
100 C C
200 C C
400 B B B B
630 B B B B
800 B B B B
Red
Sp
otRe
d S
pot
Min
iatu
reCM
, CM
P, C
MS,
CM
SESa
fecl
ip
Fuse
Sw
itch
esFu
se F
itti
ng
s
NS
2-32
ES40
-63
NIT
& N
ITL
2-20
TIA
& T
IAL
2-32
TIS
& T
ISL
35-6
3
TB2-
63
TBC
2-63
OS
80 &
100
TCP
& T
CPL
80 &
100
TFP
125
& 1
60
TC &
TC
L80
& 1
00
TF12
5-20
0
TKF
& T
KFL
250
& 3
15
TKM
250
& 3
15
TM &
TM
L35
5 &
400
TTM
& T
TML
450-
630
TLM
& T
LML
670-
800
GSA
5-20
GSA
25-7
5
GSB
25-7
5
GSG
B16
-63
Typ
e of
Eq
uip
men
t
Cla
ss o
f G
ear
C
urre
nt
Ra
tin
g (
A)
Type Number Prefix Letters & Current Range
J
K L
G Use GSB-2 AdaptorH Use SCA63 CarrierJ Except TIS63M80-63M100K Except OS100M125L Max Assisted Start Motor = 45kW
A Use AA AdaptorB Use BA AdaptorC Use CA AdaptorE Use GSA-1 AdaptorF Use GSA-2 Adaptor
RSL F
USE H
OLDE
RS
7671
TAN
04/
02
INDUSTRIAL PRODUCTS25 Princes Road Regents Park NSW 2143
Tel: 1300 556 601 Fax: 1300 550 187 www.ip.alstom.com.au