Functional Brain Signal Processing: EEG & fMRI

Lesson 18

Kaushik Majumdar

Indian Statistical Institute Bangalore Center

[email protected]

M.Tech. (CS), Semester III, Course B50

Page 2: Functional Brain Signal Processing: EEG & fMRI Lesson 18

Equipment and Acquisition

EEG electrodes to reduce eddy current by adding 5 to 10 kohm for 1.5 T fMRI scanner and/or using specialized materials for making them.

Reducing artifacts in EEG signals due to the induced current.

Reducing heat due to induced current, which may cause burn on the skin of the subject.

Page 3: Functional Brain Signal Processing: EEG & fMRI Lesson 18

Equipment and Acquisition (cont)

Every fMRI scanner is equipped with a very sensitive RF detector. If EEG equipment produces any RF wave that would contaminate the fMRI signal. To avoid this amplifier/digitizer can be run on battery.

Water based electrode gels proofed to produce negligible chemical shift artifacts on the scalp surface.

Page 4: Functional Brain Signal Processing: EEG & fMRI Lesson 18

Equipment and Acquisition (cont)

High sampling rate (1 to 5 kH) for EEG is required for good modeling of MR artifacts.

Helium pump and other unnecessary apparatus should be kept switched off during acquisition to avoid noise due to those equipments.

Digitized signal to be carried out of the shielded room through optical fibers to preserve isolation of the MR scanner.

Page 5: Functional Brain Signal Processing: EEG & fMRI Lesson 18

Equipment and Acquisition (cont)

To reduce residual artifacts in EEG due to MR scanning following must be adhered to:

(1) MR volume acquisition must be stable in time (always equal time lag in between any two successive volume acquisition).

(2) MR device and EEG amplifier will have to be synchronized.

Page 6: Functional Brain Signal Processing: EEG & fMRI Lesson 18

EEG and fMRI Data Fusion

A brain region may have a large metabolic load without measurable EEG generation. This can happen in deep brain region from where EEG will not reach to the electrodes on the scalp. EEG activity tangential to the scalp or opposing and self-canceling sources in the sulci may have substantial metabolic demand without significant EEG manifestation.

Page 7: Functional Brain Signal Processing: EEG & fMRI Lesson 18

EEG and fMRI Data Fusion (cont)

Inhibitory neuronal (for example GABA-ergic stellate cells, which do not generate measurable EEG due to concentric configuration) activities on fMRI are unpredictable.

A relatively small fraction of synchronously firing neurons may generate a measurable EEG on the scalp without a strong enough hemodynamic activity.

Page 8: Functional Brain Signal Processing: EEG & fMRI Lesson 18

EEG and fMRI Data Fusion (cont)

An increase in neuronal synchrony associated with a decrease in synaptic transmission will be associated with higher EEG amplitudes and a negative fMRI signal.

Linden et al., 1999

BOLD response to T = target and N = non-target.

Page 9: Functional Brain Signal Processing: EEG & fMRI Lesson 18

Evoked Potential During the Same Task of the Preceding Slide

Linden et al., 1999

Event related potential during visual odd-ball task. Black line for targets and grey for non-targets.

Page 10: Functional Brain Signal Processing: EEG & fMRI Lesson 18

BOLD Response to Interictal Epileptic Discharges

Arrows indicate interictal epileptic discharges.

Benar et al., 2002

Page 11: Functional Brain Signal Processing: EEG & fMRI Lesson 18

fMRI Localization of EEG/MEG Sources

Liu et al., 1998

Simultaneous EEG-fMRI significantly improves source localization of EEG over the classical dipole source estimation.A. K. Liu et al., PNAS, 95(5): 8945 – 8950, 1998.

Page 12: Functional Brain Signal Processing: EEG & fMRI Lesson 18

Converting EEG to RF Range to be Detected by MR Scanner

Hanson et al., 2007

Page 13: Functional Brain Signal Processing: EEG & fMRI Lesson 18

References

P. Ritter and A. Villringer, Simultaneous EEG-fMRI, Neurosci. Behav. Rev., 30: 823 – 838, 2006.

http://fsl.fmrib.ox.ac.uk/eeglab/fmribplugin/ Artifact removal toolbox based on MATLAB. For the detail of algorithms see R. K. Niazy et al., Removal of FMRI environment artifacts from EEG data using optimal basis set, NeuroImage, 28: 720 – 737, 2005.