Full Specification Set - Small Business
Transcript of Full Specification Set - Small Business
PDH14-K “H” in part number indicates halogen lighting. These models not available with heat lamps. Shown with optional duct cover (sold separately). Optional duct covers available in standard and custom sizes.
EUROSTYLE WALL MOUNT RANGE HOOD SPECIFICATIONS
*Exceeding recommended mounting height may
compromise performance.
ULC USR
Connection Diagram (30" - 48" Widths) RecommendedMounting Height
Electrical/Mechanical Specifications For Blower Units
Model Volts Amps* Hz RPM [email protected]" Equivalent CFM• CFM
[email protected]"Minimum Round
Duct Size Sones#
K250 (Top Vent) 115 3.2 60 1550 250 375 223 220 190 7" (38 in.2) 7.4* Add 0.5 amp for each halogen light. Hood is available with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 48").• BecausetheMagicLung®blowerusescentrifugalfiltrationratherthanconventionalbaffleormeshfilters,theMagicLung®blowercanhandlecookingequipmentwithhighercubicfeetperminute(CFM)requirementsandcandeliverequivalentCFMmuchmoreefficientlythanotherthanotherfiltrationsystems.WhencomparingtheMagicLung®withotherblowerunitsmadebyothermanufacturers,usethe“EquivalentCFM”.
# RatingsinaccordancewiththeStandardTestCodebytheEnergySystemsLaboratoryoftheTexasEngineeringExperimentStation.SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0310A
(Front View)
(Top View)
PDH14-K
OPTIONAL DUCT
COVER
7" Round
PD14/PDH14/SLD14/SLDH14 “H” in part number indicates halogen lighting. These models not available with heat lamps. Shown with optional duct cover (sold separately). Optional duct covers available in standard and custom sizes.
Connection Diagram (36”- 48” Widths)
EUROSTYLE WALL MOUNT RANGE HOOD SPECIFICATIONS
30” model is limited to B100 single blower only
*Exceeding recommended mounting height may
compromise performance.
CenterlineOf Hood
Electrical
6" Outlet
Wall Side
VentHole
1 7⁄8”1 ¾”
5 ¼”
Electrical
1 ¾”
Centerlineof Hood
8” Outlet
VentHoles
5 ¼”5 ½”Wall Side
BlowerExhaustOutlet
5"
14"
6" Round
14"
BlowerExhaustOutlet
5"8" Round
ULC USR
OPTIONAL DUCT
COVER
PD14/PDH14 SLD14/SLDH14
Connection Diagram (30" - 48" Widths) RecommendedMounting Height
(Front View)300 CFM B100 Single Blower(Top View)
(Front View)600 CFM B200 Dual Blower(Top View)
OPTIONAL DUCT
COVER
Electrical/Mechanical Specifications For Blower Units
Model Volts Amps* Hz RPM [email protected]" Equivalent CFM• CFM
[email protected]"Minimum Round
Duct Size Sones#
B100 Single 115 1.5 60 1550 300 450 273 245 225 6" (28 in.2) 5.4B200 Dual 115 2.9 60 1550 600 900 531 480 430 8" (50 in.2) 6.5
* Add0.5ampforeachhalogenlight.Hoodisavailablewithasinglefluorescentlightorwithhalogenlights(2lights:30"-41",3lights:42"-48").• BecausetheMagicLung®blowerusescentrifugalfiltrationratherthanconventionalbaffleormeshfilters,theMagicLung®blowercanhandlecookingequipmentwithhighercubicfeetperminute(CFM)requirementsandcandeliverequivalentCFMmuchmoreefficientlythanotherthanotherfiltrationsystems.WhencomparingtheMagicLung®withotherblowerunitsmadebyothermanufacturers,usethe“EquivalentCFM”.
# RatingsinaccordancewiththeStandardTestCodebytheEnergySystemsLaboratoryoftheTexasEngineeringExperimentStation.SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0210A
EP(X)18/EP(X)H18/NEP(X)18/NEP(X)H18/SEP(X)18/SEP(X)H18 “H” in part number indicates halogen lighting. These models not available with heat lamps. Shown with optional duct cover (sold separately). Optional duct covers available in standard and custom sizes.
EUROSTYLE WALL MOUNT RANGE HOOD SPECIFICATIONS
(X) in part number indicates 27” depth
600 CFM B200 Dual Blower(Top View)
(Front View)
*Exceeding recommended mounting height may
compromise performance.
Electrical
1 ¾”
Centerlineof Hood
8” Outlet
VentHoles
5 ¼”5 ½”Wall Side
18"
Blower ExhaustOutlet
9"8" Round
ULC USR
NEP(X)18/NEP(X)H18EP(X)18/EP(X)H18 SEP(X)18/SEP(X)H18
Connection Diagram (36" - 48" Widths) RecommendedMounting Height*
Electrical/Mechanical Specifications For Blower Units
Model Volts Amps* Hz RPM [email protected]" Equivalent CFM• CFM
[email protected]"Minimum Round
Duct Size Sones#
B200 Dual 115 2.9 60 1550 600 900 531 480 430 8" (50 in.2) 6.5* Add0.5ampforeachhalogenlight.Hoodisavailablewithasinglefluorescentlightorwithhalogenlights(2lights:30"-41",3lights:42"-48").• BecausetheMagicLung®blowerusescentrifugalfiltrationratherthanconventionalbaffleormeshfilters,theMagicLung®blowercanhandlecookingequipmentwithhighercubicfeetperminute(CFM)requirementsandcandeliverequivalentCFMmuchmoreefficientlythanotherthanotherfiltrationsystems.WhencomparingtheMagicLung®withotherblowerunitsmadebyothermanufacturers,usethe“EquivalentCFM”.
# RatingsinaccordancewiththeStandardTestCodebytheEnergySystemsLaboratoryoftheTexasEngineeringExperimentStation.SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 1210A
OPTIONAL DUCT
COVER
OPTIONAL DUCT
COVER
OPTIONAL DUCT
COVER
EP(X)T18/EP(X)TH18/NEP(X)T18/NEP(X)TH18/SEP(X)T18/SEP(X)TH18 “H” in part number indicates halogen lighting. These models not available with heat lamps. Shown with optional duct cover sold separately). Optional duct covers available in standard and custom sizes.
Connection Diagram (54” - 66” Widths)
EUROSTYLE WALL MOUNT RANGE HOOD SPECIFICATIONS
*Exceeding recommended mounting height may
compromise performance.
CenterlineOf Hood
Wall Side
Electrical (2)
10" OutletCentered On
Hood Top
12 �⁄�” 9 �⁄�”
1 ¾”
Wall Side
7"Electrical (2)
CenterlineOf Hood
12" OutletCentered OnTop Of Hood
1 ¾”
16 ½” 5 ½”1 ¾”
18"
10"
8 ½”
18"
12"
7 ½"
ULC USR
(X) in part number indicates 27” depth
NEP(X)T18/NEP(X)TH18EP(X)T18/EP(X)TH18 SEP(X)T18/SEP(X)TH18
The transition shown (VP562 & VP563) is installed in the hood
at the factory as a standard item. It will be located in the
exact center of the duct cover (left to right & front to rear).
Duct Cover(Top of Hood)
10" Dia. or 12" Dia.Transition Location
"Centered"
Connection Diagram (42" - 66" Widths) RecommendedMounting Height
900 CFM B200 Dual & B100 Single Blower(Top View)
VP562 Standard TransitionInstalled (Front View)
1200 CFM Double B200 Dual Blowers(Top View)
VP563 Standard TransitionInstalled (Front View)
Electrical/Mechanical Specifications For Blower Units
Model Volts Amps* Hz RPM [email protected]" Equivalent CFM• CFM
[email protected]"Minimum Round
Duct Size Sones#
B200 Dual & B100 Single 115 4.4 60 1550 900 1350 804 725 655 10" (79 in.2) 6.3Two B200 Duals 115 5.8 60 1550 1200 1800 1062 960 860 12" (113 in.2) 6.6
* Add0.5ampforeachhalogenlight.Hoodisavailablewithfluorescentlights(oneforeachsingleordualblower)orwithhalogenlights(3lights:42"-53",4lights:54"-66").• BecausetheMagicLung®blowerusescentrifugalfiltrationratherthanconventionalbaffleormeshfilters,theMagicLung®blowercanhandlecookingequipmentwithhighercubicfeetperminute(CFM)requirementsandcandeliverequivalentCFMmuchmoreefficientlythanotherthanotherfiltrationsystems.WhencomparingtheMagicLung®withotherblowerunitsmadebyothermanufacturers,usethe“EquivalentCFM”.
# RatingsinaccordancewiththeStandardTestCodebytheEnergySystemsLaboratoryoftheTexasEngineeringExperimentStation.SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 1210A
OPTIONAL DUCT
COVER
OPTIONAL DUCT
COVER
OPTIONAL DUCT
COVER