Fuel monitoring step by step

1
UniGuard Technology Limited www.uniguardgps.com Below are step by step of vehicle fuel monitoring including installation and configuration. Please choose the most convenient one for your fuel monitoring testing. GPS Tracker must be setup to be tracked online first. ACC MUST BE ON WHEN EACH (SMS/GPRS) COMMAND IS SENT. Otherwise the reply is Failure. Solution 1: Configuration via sending SMS commands from cell phone 1. Connect UT04 fuel check line to vehicle fuel own sensor line correctly. Check the First Step here http://www.uniguardgps.com/Support/Faqs/21.html 2. Stop vehicle at a place with good signal. Go to dashboard to check how much fuel is left in Percentage. If 80% fuel is left, TURN ON ACC, send command A000000,017,80 Tracker will reply a message like (80,XX) XX is a measure value. It must be recorded. 3. Add or reduce fuel. If fuel then is 60% left, TRUN ON ACC, send command A000000,017,60 Tracker will reply a message like (80,XX) XX is a measure value. IT must be recorded. 4. Add or Reduce fuel. If fuel then is 30% left, TURN ON ACC, send command A000000,017,30 Tracker will reply a message like (30,XX) XX is a measure value. IT must be recorded. 5. Add or Reduce fuel. If fuel then is 10% left, TURN ON ACC, send command A000000,017,10 Tracker will reply a message like (10XX) XX is a measure value. IT must be recorded. If you do not want to add or reduce fuel, just send command day by day. (ACC MUST BE ON WHEN EACH COMMAND IS SENT. Otherwise the reply is Failure.) 6. After getting 4 measures, Check Link http://www.uniguardgps.com/Support/Faqs/21.html and check Step III Solution 2: Configuration via sending GPRS commands from web or PC system 1. Connect UT04 fuel check line to vehicle fuel own sensor line correctly. Check the First Step here http://www.uniguardgps.com/Support/Faqs/21.html 2. As your account is ADMIN account, you have right to send command online Send scheduling instructions3. Double click the device on list, Choose Position, click Send 4. Below show Command has been sent 5. Tracker will reply vehicle current status, including Car Plate No. Device ID, Coordinates, Speed, Time, Vehicle State 6. In Vehicle State, it will show ACC ON, Oil XXXX is the measure value. Record the XX and vehicle current fuel left percentage 7. Wait for a while, send another command and do recording. 8. After getting 4 measures, Check Link http://www.uniguardgps.com/Support/Faqs/21.html and check Step III Video checking/downloading at http://www.uniguardgps.com/Support/Software/ For any more questions, please contact us by [email protected]

Transcript of Fuel monitoring step by step

Page 1: Fuel monitoring step by step

UniGuard Technology Limited

www.uniguardgps.com

Below are step by step of vehicle fuel monitoring including installation and configuration. Please

choose the most convenient one for your fuel monitoring testing.

GPS Tracker must be setup to be tracked online first.

ACC MUST BE ON WHEN EACH (SMS/GPRS) COMMAND IS SENT. Otherwise the reply is Failure.

Solution 1: Configuration via sending SMS commands from cell phone

1. Connect UT04 fuel check line to vehicle fuel own sensor line correctly. Check the First Step

here http://www.uniguardgps.com/Support/Faqs/21.html

2. Stop vehicle at a place with good signal. Go to dashboard to check how much fuel is left in

Percentage. If 80% fuel is left, TURN ON ACC, send command A000000,017,80 Tracker will reply a

message like (80,XX) XX is a measure value. It must be recorded.

3. Add or reduce fuel. If fuel then is 60% left, TRUN ON ACC, send command A000000,017,60

Tracker will reply a message like (80,XX) XX is a measure value. IT must be recorded.

4. Add or Reduce fuel. If fuel then is 30% left, TURN ON ACC, send command A000000,017,30

Tracker will reply a message like (30,XX) XX is a measure value. IT must be recorded.

5. Add or Reduce fuel. If fuel then is 10% left, TURN ON ACC, send command A000000,017,10

Tracker will reply a message like (10XX) XX is a measure value. IT must be recorded.

If you do not want to add or reduce fuel, just send command day by day.

(ACC MUST BE ON WHEN EACH COMMAND IS SENT. Otherwise the reply is Failure.)

6. After getting 4 measures, Check Link http://www.uniguardgps.com/Support/Faqs/21.html and

check Step III

Solution 2: Configuration via sending GPRS commands from web or PC system

1. Connect UT04 fuel check line to vehicle fuel own sensor line correctly. Check the First Step

here http://www.uniguardgps.com/Support/Faqs/21.html

2. As your account is ADMIN account, you have right to send command online “Send scheduling

instructions”

3. Double click the device on list, Choose Position, click Send

4. Below show “Command has been sent”

5. Tracker will reply vehicle current status, including Car Plate No. Device ID, Coordinates, Speed,

Time, Vehicle State

6. In Vehicle State, it will show “ACC ON, Oil XX” XX is the measure value. Record the XX and

vehicle current fuel left percentage

7. Wait for a while, send another command and do recording.

8. After getting 4 measures, Check Link http://www.uniguardgps.com/Support/Faqs/21.html and

check Step III

Video checking/downloading at http://www.uniguardgps.com/Support/Software/

For any more questions, please contact us by [email protected]