FT3000 Power Filter Characteristic Tester · 2020. 1. 9. · e c t t o m o d i f i c a t i o...

1
05 subject to modification 2F,4Cell, Tower C, In.Do Mansion,No.48A Zhichun Road, Haidian DistrictBeijing, China (100098) Tel. +86 (10) 8275 5151(reception) Tel. +86 (10) 82755151ext.8887 Fax. +86 (10) 8275 5151-8103 [email protected] [email protected] www.relaytest.com PR PONOVO POWER CO., LTD. FT3000 Power Filter Characteristic Tester Precisely and automatically complete power filter amplitude frequency and phase frequency characteristic measurement Automatically measure power filter by parameters of reactor, capacitor and resistor Compensate and measure capacitor group unbalanced current 0.01 mA—10 mA Main Functions Characteristic Graph Key Board Shortcut Key Mouse USB Port Signal source technical parameters 60V RMS 5A 5Hz—3000Hz 0.1 Hz Max output voltage Frequency control step Max output ccurrent Output frequency Report LCD Dimension Weight 1000 Reports 8.4" TFT 364 mm×200 mm×475mm (W×H×D) 11.8kg Other Operation Conmunication Port Self Protection Report Overload/Overheat 1000 Reports Off-line operation/External PC operation USB/100M Ethernet Technical Parameters Impedance frequency, phase frequency, resistance, inductance and capacitance measurement. Unbalanced current measurement f(5-3000Hz) Output Analog Double-tuned power filter f(5-3000Hz) 0.01mA-10mA Compensation capacitance group FT3000 Power Filter Characteristic Tester FT3000 Power Filter Characteristic Tester Output Analog Measurement system technical parameters Voltage Frequency Current Accuracy Frequency Amplitude Impedance measurement range Impedance measurement accuracy Phase measurement accuracy Inductance measurement range Inductance measurement accuracy Capacitance measurement accuracy Capacitance measurement range Unbalance current measurement accuracy Frequency output Amplitude output Accuracyq Amplitude 0.5% 5Hz—3000Hz 0.2V—60V 0.5% 5Hz—3000Hz 0.01 A—10 A ΩKΩ 1 6 0.5% ° 1 mH—10H 2 0.5% 0.5% 0.05uF-500uF 0.5% 100Hz—3000Hz 0.01 mA—10 mA

Transcript of FT3000 Power Filter Characteristic Tester · 2020. 1. 9. · e c t t o m o d i f i c a t i o...

Page 1: FT3000 Power Filter Characteristic Tester · 2020. 1. 9. · e c t t o m o d i f i c a t i o 2F,4Cell, Tower C, In.Do Mansion,No.48A Zhichun Road, Haidian DistrictBeijing, China (100098)

05

su

bje

ct to

mo

dific

atio

n

2F,4Cell, Tower C, In.Do Mansion,No.48A Zhichun Road, Haidian DistrictBeijing, China (100098)Tel. +86 (10) 8275 5151(reception) Tel. +86 (10) 82755151ext.8887Fax. +86 (10) 8275 5151-8103 [email protected] [email protected] www.relaytest.com

PR

PONOVO POWER CO., LTD.

FT3000 Power Filter Characteristic Tester

Precisely and automatically complete power filter amplitude

frequency and phase frequency characteristic measurement

Automatically measure power filter by parameters of reactor,

capacitor and resistor

Compensate and measure capacitor group unbalanced current

0.01 mA—10 mA

Main Functions

Characteristic Graph Key Board

Shortcut Key Mouse

USB Port

Signal source technical parameters60V RMS

5A 5Hz—3000Hz

0.1 Hz

Max output voltage

Frequency control step

Max output ccurrent Output frequency

Report

LCD

Dimension Weight

1000 Reports

8.4" TFT

364 mm×200 mm×475mm (W×H×D)11.8kg

Other

Operation

Conmunication Port

Self Protection

ReportOverload/Overheat

1000 Reports

Off-line operation/External PC operation

USB/100M Ethernet

Technical Parameters

Impedance frequency, phase frequency, resistance, inductance and capacitance measurement. Unbalanced current measurement

f(5-3000Hz)Output

Analog

Double-tuned power filter

f(5-3000Hz)

0.01mA-10mA

Compensation capacitance group

FT3000 Power Filter Characteristic Tester

FT3000 Power Filter Characteristic Tester

Output

Analog

Measurement system technical parametersVoltage

Frequency

Current

Accuracy

Frequency Amplitude

Impedance measurement rangeImpedance measurement accuracy

Phase measurement accuracy

Inductance measurement range

Inductance measurement accuracy

Capacitance measurement accuracy

Capacitance measurement range Unbalance current measurement accuracy

Frequency output

Amplitude output

Accuracyq

Amplitude

0.5%

5Hz—3000Hz

0.2V—60V

0.5%

5Hz—3000Hz0.01 A—10 A

Ω— KΩ1 6

0.5%

°1mH—10H2

0.5%

0.5%

0.05uF-500uF0.5%

100Hz—3000Hz

0.01 mA—10 mA