Fronius IG Plus 100V 2-ph NR - Magazin Panouri Fotovoltaice IG Plus... · 2013-06-19 · Fronius IG...

2
SOPHISTICATED TECHNOLOGY FOR GREATER OUTPUT F r onius IG Plus 100 V , IG Plus 120 V , IG Plus 150 V INVERTER With a maximum efficiency to 95,9%, these inverters from the Fronius IG Plus V series achieve top values in output. The reason behind this is the sophisticated technology such as the Fronius Module-ManagerTM (MPP tracker), which always finds the optimal operating point, even un- der changing sunlight conditions. The power boards are switched on and off automatically, always ensuring the maximum energy output relative to duration of operation and sunlight. Another technological advantage is that the modular design reliably reduces potential downtime, since a failure affects only the power board in question and not the entire device. HIGHLIGHTS Suitable for all module types with phase grounding, especially for thin-film modules Maximum efficiency to 95,9% Redundant system for continuous power generation due to the MIXTM concept Fronius Module Manager TM ensures maximum performance through maximum power point (MPP) 5-year product warranty optional extension to 20 years*

Transcript of Fronius IG Plus 100V 2-ph NR - Magazin Panouri Fotovoltaice IG Plus... · 2013-06-19 · Fronius IG...

SOPHISTICATED TECHNOLOGY FOR GREATER OUTPUT

Fronius IG Plus 100 V, IG Plus 120 V, IG Plus 150 V

INVERTER

With a maximum efficiency to 95,9%, these inverters from the Fronius IG Plus V series achieve top values in output. The reason behind this is the sophisticated technology such as the Fronius Module-ManagerTM (MPP tracker), which always finds the optimal operating point, even un- der changing sunlight conditions. The power boards are switched on and off automatically, always ensuring the maximum energy output relative to duration of operation and sunlight. Another technological advantage is that the modular design reliably reduces potential downtime, since a failure affects only the power board in question and not the entire device.

HIGHLIGHTS

� Suitable for all module types with phase grounding, especially for thin-film modules

� Maximum efficiency to 95,9%

� Redundant system for continuous power generation due to the MIXTM concept

� Fronius Module ManagerTM ensures maximum performance through maximum power point (MPP)

� 5-year product warranty – optional extension to 20 years*

TECHNICAL DATA Fronius IG Plus 100V (2) Plus 100V (3) Plus 120V (3) Plus 150V (3)

Input DC-nominal power (W)

Max. input current (A)

Max. input voltage(V)

Min. MPP-voltage at nominal Uac (V)

Max. MPP-voltage (V)

8400

37,0

600

230

500

8430

36,7

600

230

500

10500

46,0

600

230

500

12600

55,5

600

230

500

Output AC-nominal power (VA)

Power factor (cos phi)

number of grid input phases

Min. AC frequency (Hz)

Max. AC frequency (Hz)

Min. AC grid voltage (V)

Max. AC grid voltage (V)

8000

ADJUSTABLE

2

46

65

180

270

8000

ADJUSTABLE

3

46

65

180

270

10000

ADJUSTABLE

3

46

65

180

270

12000

ADJUSTABLE

3

46

65

180

270

Degree of efficiency Max. efficiency (%)

Euro. efficiency (%)

Operating consumption in night mode (W)

95,7

95,2

1

95,9

95,3

1

95,9

95,4

1

95,9

95,4

1

Security Technology TRAFO TRAFO TRAFO TRAFO

Conditions Ambient temperature (°C )

Humidity (%) -20 TO + 55

0 TO 95 -20 TO + 55

0 TO 95 -20 TO + 55

0 TO 95 -20 TO + 55

0 TO 95

Equipment Type of DC-connector

DC switch

Protection rating (IP)

Width (mm)

Height (mm)

Depth (mm)

Weight (kg)

Output cross section (mm2)

CLAMP

YES

54

434

968

250

36,9

25

CLAMP

YES

54

434

1263

250

49,2

25

CLAMP

YES

54

434

1263

250

49,2

25

CLAMP

YES

54

434

1263

250

49,2

25

09.03.2012 � Innovative power plug system � Connection area and power modules are installed separately from one another

Your PETAWATT ENERGIA partner: * Product and power warranty in accordance with the version of the full warranty conditions received from your PETAWATT ENERGIA partner at the time of installation. This warranty is valid only when the relevant product is installed in accordance with the applicable installation instructions. Subject to modifications that represent progress.

www.e-solare.ro PETAWATT ENERGIA | Str.Faget,nr.6 | 110386 Pitesti-Arges | Phone +40 248 223 003