FREQUENTLY ASKED QUESTIONS ETERNITY PE/GE/ME/LE Date: 2 nd June, 2015 Version: V1R1 Author: Saurabh Sharma

Transcript of FREQUENTLY ASKED QUESTIONS - IP PBX … · Step 3: Configure E1 CAS Signaling. Select Line Coding...

FREQUENTLY ASKED QUESTIONS

ETERNITY PE/GE/ME/LE

Date: 2nd June, 2015

Version: V1R1

Author: Saurabh Sharma

How to troubleshoot and fix the issues faced during E1 CAS (DTMF) installations?

ISDN Service Provider

E1 CAS

ETERNITY GE

Configuration Steps: Step 1: T1E1 configuration. Login as SE and go to T1E1 configuration.

Step 2: Configure T1E1 Port Parameters for E1 CAS.

Note: If Line Coding Mechanism & Framing Mode are not configured as provided by the service provider then there may be signalling issue between PBX and ISDN Switch. Step 3: Configure E1 CAS Signaling.

Select Line Coding Mechanism &

Framing Mode as provided by

Service Provider

Step 4: Check the Status.

Troubleshooting Steps: Issue 1: Noise is observed during speech.

Clear Alarm/Counter available under the Status T1E1 Configuration and observe the Status page again (Once cleared it should not generate more alarms).

Note: Alarm generation in status page is available from version V12R1 onwards.

If still the Alarm counter is varying then set the Clock Synchronization parameter.

Set Clock Source

Priority 1

Set Clock Source

Priority 2,3,4 as None

Set the Clock Synchronization Frequency

as 2.048 MHz in E1-CAS

Issue 2: E1 CAS line is not working.

Check the T1E1 port by Loop back.

Connect (Pin 1 --- Pin 4) & (Pin 2 --- Pin 5) of RJ45 cable as shown below

Connect patch code with T1E1 card.

If both the LEDs are green in colour in loop back test, then check the connectivity from service provider side. For other then the green LED indication, check the T1E1 card hardware.

Both LEDs L1 & L2 are

continuous Green on

connecting RJ45 cable.

Issue 3: Delayed incoming call.

Change the Overlap Receiving Timer under advance option in T1E1 Port Parameters (Default: 15 sec).

Issue 4: Incoming call landing issue. Let us understand the call flow in E1 CAS.

Check the master debug for the incoming call request .

E1CAS : S-1 P-1 Recv : 21 19 48 67 57 1 1 49 4 0 128 144 163 54 6 1 128 55

48 48 49

SetupIn(21) TLen=19 CdId(48)=67 ChId(57)= 1 1 BC(49) L=4 CallerNum(54)

L=6 NC=1 PS=128 CLI=7001

MyPortId::832

InitAndSendBlfParaForDS1::2055

T1E1-1-1 State = TrkIcWait

T1E1-1-1 State = Dial Tone

E1CAS : S-1 P-1 Send : 18 5 48 67 57 1 1

IcSetupAckRQ(18) TLen=5 CdId(48)=67 ChId(57)= 1 1

InitAndSendBlfParaForDS1::2055

E1CAS : S-1 P-1 Recv : 23 6 48 67 52 2 129 51

InfoIn(23) TLen=6 CdId(48)=67 CalledNum(52) L=2 NS=129 Num=3

T1E1-1-1 State = Access

E1CAS : S-1 P-1 Recv : 23 6 48 67 52 2 129 48

InfoIn(23) TLen=6 CdId(48)=67 CalledNum(52) L=2 NS=129 Num=0

E1CAS : S-1 P-1 Recv : 23 6 48 67 52 2 129 48

InfoIn(23) TLen=6 CdId(48)=67 CalledNum(52) L=2 NS=129 Num=0

InitAndSendBlfParaForDS1::2055

E1CAS : S-1 P-1 Recv : 23 6 48 67 52 2 129 49

InfoIn(23) TLen=6 CdId(48)=67 CalledNum(52) L=2 NS=129 Num=1

T1E1-1-1 State = Placed

InitAndSendBlfParaForDS1::2055

E1CAS : S-1 P-1 Send : 19 2 48 67

IcProcRQ(19) TLen=2 CdId(48)=67

InitAndSendBlfParaForDS1::2055

E1CAS : S-1 P-1 Send : 21 2 48 67

IcAlertRQ(21) TLen=2 CdId(48)=67

InitAndSendBlfParaForDS1::2055

InitAndSendBlfParaForDS1::2055

E1CAS : S-1 P-1 Send : 22 2 48 67

IcConnRQ(22) TLen=2 CdId(48)=67

HandOff is set successfully on Index :0

T1E1-1-1 State = 2 Party Spch

T1E1-1-1 State = TrkIdleWait

InitAndSendBlfParaForDS1::2055

E1CAS : S-1 P-1 Send : 38 4 48 67 56 144

DiscRQ(38) TLen=4 CdId(48)=67 Cause(56) =16

InitAndSendBlfParaForDS1::2055

E1CAS : S-1 P-1 Recv : 40 4 48 67 56 144

ReleaseCmpltIn(40) TLen=4 CdId(48)=67 Cause(56) =16

Here called number (3001) is found in the InfoIn request coming from line

which indicates that call is getting received by the system.

Ext No. 2001

If no DTMF digits are present in InfoIn request then change the DTMF Detection settings (Minimum up to 10 msec) under advance option in T1E1 Port Parameters .

E1 CAS

DTMF

Detection Digits

dial

1,2…

If still incoming call is not working then we can check slave layer debug

(ARM Debug) for exact call flow analysis.

Matrix technical support team will analyze ARM debug for further

diagnosis. Please arrange COM port cable for debugging if ETERNITY ME/

ETERNITY LE is used.

Issue 5: No dial tone while grabing the E1 CAS line.

Check dial tone by Selective Port Access of the E1- Port. (Command: 69-05-01)

Increase the Line Seizure, Acknowledge Wait Timer in E1 CAS Signaling and check .

Check the master debug for outgoing call E1CAS : S-12 P-1 Send : 16 19 48 36 57 0 1 49 4 0 128 144 163 54 6 1 128 55 48 48 49 SetupRQ(16) TLen=19 CdId(48)=36 ChId(57)= 0 1 BC(49) L=4 CallerNum(54) L=6 NC=1 PS=128 CLI=7001 Eon: S-2 P-1 Send Len-58 CursorRq 0 63 E1CAS : S-12 P-1 Recv : 16 5 48 36 57 0 1 SetupAckIn(16) TLen=5 CdId(48)=36 ChId(57)= 0 1 InitAndSendBlfParaForDS1::2055 Eon: S-2 P-1 Send Len-58 CursorRq 0 63 E1CAS : S-12 P-1 Send : 23 6 48 36 52 2 129 51 InfoRQ(23) TLen=6 CdId(48)=36 CalledNum(52) L=2 NS=129 Num=3 E1CAS : S-12 P-1 Send : 23 6 48 36 52 2 129 48 InfoRQ(23) TLen=6 CdId(48)=36 CalledNum(52) L=2 NS=129 Num=0 E1CAS : S-12 P-1 Send : 23 6 48 36 52 2 129 48 InfoRQ(23) TLen=6 CdId(48)=36 CalledNum(52) L=2 NS=129 Num=0 E1CAS : S-12 P-1 Send : 23 6 48 36 52 2 129 49 InfoRQ(23) TLen=6 CdId(48)=36 CalledNum(52) L=2 NS=129 Num=1 E1CAS : S-12 P-1 Recv : 17 5 48 36 57 0 1 OgProcIn(17) TLen=5 CdId(48)=36 ChId(57)= 0 1 InitAndSendBlfParaForDS1::2055 Active Request Not Possible-It is not IC Call mMyFsmId=832 T1E1-1-1 State = 2 Party Spch Active Request Not Possible-It is not IC Call mMyFsmId=832 E1CAS : S-12 P-1 Recv : 19 5 48 36 57 0 1 OgAlertIn(19) TLen=5 CdId(48)=36 ChId(57)= 0 1 E1CAS : S-12 P-1 Recv : 20 5 48 36 57 0 1 OgConnIn(20) TLen=5 CdId(48)=36 ChId(57)= 0 1 InitAndSendBlfParaForDS1::2055 E1CAS : S-12 P-1 Send : 17 2 48 36 OgConnAckRq(17) TLen=2 CdId(48)=36 HandOff is set successfully on Index :0 DiscIn(38) TLen=4 CdId(48)=36 Cause(56) =16 InitAndSendBlfParaForDS1::2055 E1CAS : S-12 P-1 Send : 39 4 48 36 56 144 RelRQ(39) TLen=4 CdId(48)=36 Cause(56) =16 E1CAS : S-12 P-1 Recv : 40 4 48 36 56 128 ReleaseCmpltIn(40) TLen=4 CdId(48)=36 Cause(56) =0

If SetupAckin is not received against the SetupRQ then check the settings from the Service Provider end.

Note: In case if Matrix ETERNITY is connected with BPL Exchange at the other end and if you are not getting a dial tone, check by disabling the Line Signaling flag (Default: Enabled).

For more information, contact Matrix Technical Training Team [email protected]

Disclaimer: The information contained in this e-mail and/or attachment may contain confidential or privileged information. Unauthorized use, disclosure or copying is strictly prohibited and may constitute unlawful act and can possibly attract legal action, civil and/or criminal. The contents of this message need not necessarily reflect or endorse the views of Matrix Comsec on any subject matter. Any action taken or omitted on this message is not entirely at your risk and the originator of this message nor does Matrix Comsec take any responsibility or liability towards the same. If you are not the intended recipient, please notify us immediately and permanently delete the message.