Frenchwood Gliding Patio Doors Contents/media/aw/files/...HP Sun/HP Sun Temp 3/8" Low-E/Temp...
Transcript of Frenchwood Gliding Patio Doors Contents/media/aw/files/...HP Sun/HP Sun Temp 3/8" Low-E/Temp...
A R C H I T E C T U R A L D E T A I L F I L E 9-1 R E V . 0 3 / 0 5
F r e n c h w o o d ® G l i d i n g P a t i o D o o r s
Contents
Frenchwood® Gliding Patio Doors
Basic Unit Details
Two and Four Panel ...................................................9-2
Sidelight ...................................................................9-5
Options / Accessories
Ramped Sill Insert - Interior and Exterior ...................9-6
Andersen® Grilles .......................................................9-7
Anchoring Methods ..........................................................9-9
Joining Details .............................................................. 9-10
Suggested Product Applications .................................... 9-11
• Low-maintenance, durable exterior available in White, Sandtone, Terratone® or Forest Green colors
• Natural wood interior in pine, oak, maple or prefinished white
• Smooth, easy operation
• 20/10 year limited warranty, fully transferable non-prorated
• High-Performance™ Low-E tempered or High-Performance Sun™ Low-E tempered glass is standard
A R C H I T E C T U R A L D E T A I L F I L E9-2 R E V . 0 3 / 0 5
F r e n c h w o o d ® G l i d i n g P a t i o D o o r s
Basic Unit Details - Two and Four Panel
Vertical Section
Basic UnitScale 3" = 1'-0" (1:4)
4-9/16" (116)1-5/16" (33)
3-3/4" (95)
1" (25)
13/16" (21)
1-13/16" (46)5/8" (17)
1/4" (6)
5/16" (8)
5-13/16" (148)depending on
panel adjustment
10-9/16" (268)depending on
panel adjustment
Roug
h Op
enin
g He
ight
Unit
Dim
ensi
on H
eigh
t
Clea
r Ope
ning
Hei
ght
End bumperbeyond
Head
SillOptional Andersen®
metal sill support
Optional Andersen®
gliding insect screen.Retractable insect screen also available for two panel doors.
Optional Andersen®
oak or maple threshold
A R C H I T E C T U R A L D E T A I L F I L E 9-3 R E V . 0 3 / 0 5
F r e n c h w o o d ® G l i d i n g P a t i o D o o r s
Basic Unit Details - Two Panel
Basic UnitScale 3" = 1'-0" (1:4)
Horizontal Section
3/8" (10)3/8" (10)
4-9/16" (116)
5-3/8" (137)5-3/8" (137) 3-1/8" (79) 3-1/8" (79)
1-3/4"(44)
1-3/8"(35)
50**=2' 5-5/8" (752)80**=3' 11-5/8" (905)
50**=2' 5-5/8" (752)80**=3' 11-5/8" (905)
1-5/16" (33)
LC
Rough Opening Width
Unit Dimension Width
Active Panel Stationary Panel
Jamb JambMeeting Stile
A R C H I T E C T U R A L D E T A I L F I L E9-4 R E V . 0 3 / 0 5
F r e n c h w o o d ® G l i d i n g P a t i o D o o r s
3-1/8" (79)
Optionalauxiliary foot lock
3-1/8" (79) 3-1/8" (79) 3-1/8" (79)
LC LC
5-3/8" (137)
1-3/4"(44)
1-5/16"(33)
4-9/16"(116)
10**=2' 5-11/16" (754)12**=2' 11-11/16" (906)16**=3' 11-11/16" (1211)
5-3/8" (137)1-3/4"(44)
4-5/8" (117) 4-5/8" (117)
LC 10**=2' 4-13/16" (732)12**=2' 10-13/16" (884)16**=3' 10-13/16" (1189)
10**=2' 5-11/16" (754)12**=2' 11-11/16" (906)16**=3' 11-11/16" (1211)
10**=2' 4-13/16" (732)12**=2' 10-13/16" (884)16**=3' 10-13/16" (1189)
Optionalauxiliary foot lock
Stationary Panel
Meeting Stile Meeting Stile Jamb
Stationary Panel
Jamb
Active Panel Active Panel
Astragal
Basic Unit Details - Four Panel
Horizontal Section
Basic UnitScale 3" = 1'-0" (1:4)
A R C H I T E C T U R A L D E T A I L F I L E 9-5 R E V . 0 3 / 0 5
F r e n c h w o o d ® G l i d i n g P a t i o D o o r s
4-9/16" (116)1-5/16" (33)
4" (102)
1" (25)
13/16" (21)
1-13/16" (46)5/8" (17)
5/16" (8)
1/4" (6)
5-13/16" (148)depending on
panel adjustment
10-9/16" (268)
Unit
Dim
ensi
on H
eigh
t
Clea
r Ope
ning
Hei
ght
Roug
h Op
enin
g He
ight Head
SillOptional Andersen®
metal sill support
Optional Andersen®
oak or maple threshold
Basic Unit Details - Sidelight
Basic UnitScale 3" = 1'-0" (1:4)
Vertical Section
Horizontal Section
1-5/16"(33)
4-9/16"(116)
5-7/16"(138)
5-7/16"(138)
1-3/4"(44)
1-3/4"(44)
Unit Dimension Width
Rough Opening Width
3/8" (10) 3/8" (10)
A R C H I T E C T U R A L D E T A I L F I L E9-6 R E V . 0 3 / 0 5
F r e n c h w o o d ® G l i d i n g P a t i o D o o r s
Options / Accessories
Ramped Sill Insert - Interior and ExteriorScale 3" = 1'-0" (1:4)
Vertical Section
8
1
1-7/16" (37)
1/4"(6)
10-1/8" (257) 10-7/8" (276) maximum. Cut to fit height.5/16" (8)
5/8" (17)
1/4"(6)
1-9/16" (40)
5/16" (8) (dependingon roller adjustment)
Center Ramp
Track Cover
Exterior Ramp
Flashing by others
5/8" (17)
Note: Gliding insect screen cannot be used with ramped sill. Retractable insect screen can be used on 2 panel doors only.
Vertical Section with Retractable Insect Screen(2 panel doors only)
A R C H I T E C T U R A L D E T A I L F I L E 9-7 R E V . 0 3 / 0 5
F r e n c h w o o d ® G l i d i n g P a t i o D o o r s
Options / Accessories
Andersen® Divided Light Grilles
White
Sandtone
Terratone®
Forest Green
3/4"
7/8"
1-1/8"
2-1/4"
With Spacer
Without Spacer
Maple
Oak
Prefinished
Pine
Colonial
Modified Colonial
Modified Col W/Check Rail
Prairie A
Short Fractional
Short Fractional W/Check Rail
Tall Fractional
Tall Fractional W/Check Rail
Victorian
Renaissance
Sunburst
Specified Equal Light
Custom
HP/HP Tempered
HP Sun/HP Sun Temp
3/8" Low-E/Temp
Single-Pane Impact
Available now
Available only with 3/8" glass through the Andersen Divided Light program
Please check with Andersen for availability
Andersen®400 Series Windows
Gla
ss
Patt
erns
In
terio
r Ty
pe
Wid
th
Exte
rior C
olor
Andersen®400 Series Doors
Case
men
t & A
wnin
g
Case
men
t Pic
ture
Win
dow
Glid
ing
Win
dow
Woo
dwrig
ht®
Doub
le-H
ung
& Tr
anso
m
Woo
dwrig
ht®
Pict
ure
Win
dow
Woo
dwrig
ht®
Arch
top
& U
nequ
al L
eg A
rcht
op
Woo
dwrig
ht®
Sprin
glin
e Si
ngle
-Hun
g
Tilt-
Was
h Do
uble
-Hun
g &
Tran
som
Tilt-
Was
h Pi
ctur
e W
indo
w
Circ
le To
p™ &
Qua
rter R
ound
Arch
Sprin
glin
e™
Flex
ifram
e®
Ellip
tical
Circ
le &
Ova
l
Goth
ic
200
Serie
s Na
rrolin
e® D
oubl
e-Hu
ng &
Tran
som
Fren
chwo
od®
Glid
ing
Fren
chwo
od®
Hing
ed In
swin
g
Fren
chwo
od®
Hing
ed O
utsw
ing
Fren
chwo
od®
Patio
Doo
r Sid
elig
hts &
Tran
som
s
A R C H I T E C T U R A L D E T A I L F I L E9-8 R E V . 0 3 / 0 5
F r e n c h w o o d ® G l i d i n g P a t i o D o o r s
Andersen® Divided LightPermanent ExteriorPermanent Interiorwith Spacer
Andersen® Divided LightPermanent ExteriorPermanent Interior
Andersen® Divided LightPermanent ExteriorRemovable Interior
RemovableInterior
Andersen® Finelight™Grilles-Between-the-Glass
3/32"
5/16"
5/16" 7/16"
7/16"
45˚
2-1/4"
53˚3/8"3/8"3/8" 53˚
7/8"
45˚45˚
3/4"
53˚ 35˚
1-1/8"
35˚
1/2"
1-13/16"
5/16" 7/16"
2-1/4"7/8"3/4" 1-1/8"
1/2"
7/8"3/4" 1-1/8"
1/2" 1-13/16"
5/16"5/16"5/16"
3/16"1/8" 5/16"
1/2"
1/8"
1/2" 1/2" 1/2" 1/2"
Permanent Exterior Fibrex® Material Grille Profiles (chamfer profile). Also used for pre-finished interior, except 400 Series Woodwright® double-hung windows.
Permanent Interior Wood Grille Profiles (chamfer profile).The Fibrex® material exterior grille is used when a permanent prefinished grille is specified, except with 400 Series Woodwright® double-hung windows.
Removable Interior Wood Grille Profile (roman ogee profile). Removable Interior Wood Grille Profile (Chamfer profile).400 Series Woodwright® double-hung windows only.
Permanent Full Divided Light Grille spacer location.
Andersen® Finelight™ Grilles-Between-the-Glass.
7/16"
7/8"3/4" 1-1/8"
3/8"
3/4"
1/2"
1"
Options / Accessories
Grille Profiles • Scale = Full • Dimensions include thickness of tape.
400 Series Grille Options
A R C H I T E C T U R A L D E T A I L F I L E 9-9 R E V . 0 3 / 0 5
F r e n c h w o o d ® G l i d i n g P a t i o D o o r s
Anchoring Methods
Installation FlangeScale 3" = 1'-0" (1:4)
Threaded Masonr y Fastener / Expansion SleeveScale 3" = 1'-0" (1:4)
Patio door unit is secured in opening using threaded fasteners through the jamb (the installation flange itself cannot support the door).
Patio door unit is secured in opening by pre-drilling through side jamb into masonry.
Threaded masonry anchor (by others)
4-9/
16"
(116
)
Installation flange
Exterior sheathing
Make sure that the unit frame parts do not become bowed when using anchoring methods. Unit will not operate properly if frame parts are stressed.
Installation Flange ReversedScale 3" = 1'-0" (1:4)
Patio door unit is secured in opening using threaded fasteners through the jamb (the installation flange itself cannot support the door).
4-3/
16"
(106
)
Installation flange inreverse position.
A R C H I T E C T U R A L D E T A I L F I L E9-10 R E V . 0 3 / 0 5
F r e n c h w o o d ® G l i d i n g P a t i o D o o r s
Andersen® Joining MaterialsScale 3" = 1'-0" (1:4)
Non-Reinforced Mullion
Joining Details
Andersen® LVL Reinforced Mullion
2" Support Mullion
1-3/8" (35)
2" (51)
2" (51)
1-3/4" (44)
Structure by others
Optional Andersen®
2" support mullionwood filler
Optional Andersen®
2" support mulliontrim strip set in continuous bead of sealant each side
1-3/4" (44)
1/16"(1.5)
1-3/8 (35)
1/16" (1.5)
Optional Andersen®
2-5/8" woodcasing
Optional Andersen®
exterior vinyltrim strip setin continuousbead of sealanteach side
1-3/4" (44)3/4" (19)
3/4" (19)
Optional Andersen® trim stripset in continuous bead of sealant each side
1-3/8 (35)Optional Andersen®wood casing
Optional Andersen®LVL reinforced joining strip
Joining Compatibilty Many Andersen® units are designed to be joined with other Andersen units in a variety of non-reinforced and reinforced combinations. Other combination types and joining methods can be viewed in the Andersen® Product Guide for Professionals, in Andersen Window Studio® software, and by visiting andersenwindows.com. Combination designs should always be checked for design pressure performance requirements to ensure the appropriate joining method is specified.
A R C H I T E C T U R A L D E T A I L F I L E 9-11 R E V . 0 3 / 0 5
F r e n c h w o o d ® G l i d i n g P a t i o D o o r s
Wall TypesScale 1-1/2" = 1'-0" (1:8)
Suggested Product Applications
Vertical SectionBrick Veneer / 2 x 6" Metal Stud Framing
Vertical SectionWood Siding / 2 x 4 Wood Stud Framing
Unit
Dim
. Wid
th
3/8"(10)
Unit
Dim
ensi
on H
eigh
t
3/4"(19)
Roug
h Op
enin
g He
ight
Installationflangeat head and jambs
Optional Andersen®
metal sill support
Optional Andersen®
oak or maple threshold
Optional Andersen®
retractableinsect screen(2 paneldoor only)
Sill
Jamb
Head
3/8"(10)
Unit
Dim
. Wid
th
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Removeinstallationflange at head and jambs
Optional Andersen®
oak or maple threshold
Optional Andersen®
insect screen
Head
Jamb
Sill
Importance of Proper InstallationProper installation and maintenance of Andersen® products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, Inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product. Installation of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer.
Construction by OthersAndersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others.
NOTE: Where E.I.F.S. wall finish is adjacent to units, contact E.I.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the proper width of sealant joint around the
perimeter of the window.
NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. Installation flange may be removed where construction sequence/ detailing requires no flange.
A R C H I T E C T U R A L D E T A I L F I L E9-12 R E V . 0 3 / 0 5
F r e n c h w o o d ® G l i d i n g P a t i o D o o r s
Wall TypesScale 1-1/2" = 1'-0" (1:8)
Suggested Product Applications
Vertical SectionBrick / Concrete Masonr y Unit (CMU)
Vertical SectionE.I.F.S. / Concrete Masonr y Unit (CMU)
3/8"(10)
Unit
Dim
. Wid
th
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Installationflange at headand jambs
Optional Andersen® insectscreen
Optional Andersen®
oak or maplethreshold
Head
Jamb
Sill
Membrane flashingover installationflange(by others)
3/8"(10)
Unit
Dim
. Wid
th
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Optional Andersen®
insectscreen
Optional Andersen®
auxiliarycasing
Optional Andersen®
oak or maple threshold
Head
Jamb
Sill
Importance of Proper InstallationProper installation and maintenance of Andersen® products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, Inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product. Installation of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer.
Construction by OthersAndersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others.
NOTE: Where E.I.F.S. wall finish is adjacent to units, contact E.I.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the proper width of sealant joint around the
perimeter of the window.
NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. Installation flange may be removed where construction sequence/ detailing requires no flange.
A R C H I T E C T U R A L D E T A I L F I L E 9-13 R E V . 0 3 / 0 5
F r e n c h w o o d ® G l i d i n g P a t i o D o o r s
Wall TypesScale 1-1/2" = 1'-0" (1:8)
Suggested Product Applications
Vertical SectionStucco / Concrete Masonr y Unit (CMU) Inset Door
Vertical SectionExisting Stud Wall
3/8"(10)
Unit
Dim
. Wid
th
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
1-3/16" (30)
Installationflange at head and jambs
Optional Andersen®
insect screen
Optional Andersen®
auxiliary casing
Optional Andersen®
oak or maplethreshold
Head
Jamb
Sill
3/8"(10)
Unit
Dim
. Wid
th
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Optional Andersen®
vinyl trimboard
Optional Andersen®
rigid vinyl3/4" (19) "h" channel
Existing frame wall
Installationflange at headand jambs
Optional Andersen®
insect screen Optional Andersen®
oak or maplethreshold
Optional Andersen®
metal sill support
Head
Jamb
Sill
Importance of Proper InstallationProper installation and maintenance of Andersen® products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, Inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product. Installation of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer.
Construction by OthersAndersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others.
NOTE: Where E.I.F.S. wall finish is adjacent to units, contact E.I.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the proper width of sealant joint around the
perimeter of the window.
NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. Installation flange may be removed where construction sequence/ detailing requires no flange.
A R C H I T E C T U R A L D E T A I L F I L E9-14 R E V . 0 3 / 0 5
F r e n c h w o o d ® G l i d i n g P a t i o D o o r s
Wall TypesScale 1-1/2" = 1'-0" (1:8)
Suggested Product Applications
Vertical SectionExisting Masonr y Wall
Unit
Dim
ensi
on H
eigh
t
3/8"(10)
Unit
Dim
. Wid
th
Roug
h Op
enin
g He
ightOptional
Andersen®
Vinyl TrimBoard
Optional Andersen®
rigid vinyl 3/4" (19) "h" channel
Existing masonry wall
Installationflange at headand jambs
Optional Andersen®
insect screen
Optional Andersen®
oak or maplethreshold
Head
Jamb
Sill
Importance of Proper InstallationProper installation and maintenance of Andersen® products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, Inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product. Installation of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer.
Construction by OthersAndersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others.
NOTE: Where E.I.F.S. wall finish is adjacent to units, contact E.I.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the proper width of sealant joint around the
perimeter of the window.
NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. Installation flange may be removed where construction sequence/ detailing requires no flange.