Frame Technical Data - Steel Dor of...
Transcript of Frame Technical Data - Steel Dor of...
iIndex
FRAME TECHNICAL DATANovember 1, 2004ASSA ABLOY, the global leader
in door opening solutions
DESCRIPTION PAGE(S)
Anchors – Drywall FrameBase Anchor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35Compression Anchor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34, 36, 39Multipurpose Anchor Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17Steel Channel Anchor Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .126Security Anchor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
Anchors – Flush Frame (Masonry)Ceiling Strut . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18Conduit Compatible . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75-76Existing Wall Anchors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9, 11, 12Floor Anchor (Foot Clip) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-7Loose Spline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .128Masonry Anchors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-10Mullion Stirrup Anchor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18Multipurpose Anchor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16Steel Stud Anchor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13-14Wire Truss Anchor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15Wood Stud Anchor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Borrowed Lite Frames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41-42Cabinet Jamb Frames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90CCW Stick Length Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .109-120Communicating Frames/Mullion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .96CURRIElum Emergency Egress Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .132Curriseal Frames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92-93Currisound Frames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .94-95Custom Frame Profiles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .121-122Double Egress Frames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2, 107Drywall Frames
Corner Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32-33Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40Profiles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36-38Throat Filler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
Erection Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .129-130ElectroLynx System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .131Fabricaton Frame Corner Details
Cutting and Notching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27-31Field Splice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24Welded Corner Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19-23
Flush Masonry FramesCorner Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3Profiles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-5
iiIndexFRAME TECHNICAL DATAJuly, 2007 ASSA ABLOY, the global leader
in door opening solutions
DESCRIPTION PAGE(S)
Grout Hole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .85Hardware
Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44-48Preparations
•Automatic Flush Bolts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .87•Closer Preparations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .77-81•Coordinator Preparations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .84•Deadlock Strike Preparations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67•Electric Strike Preparations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .74, 88, 89•Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68-71
Exit Device Preparations•Rim Exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .73•Vertical Rod Exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72
Flush Bolt Preparations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .86-87Hinge Preparations
•4-1/2" . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50•5" . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51•Anchor Hinge Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58•Continuous Hinge Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55•Electric Hinges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52, 57•Double Acting Hinges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59•Full width Hinge Reinforcement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54•High Frequency Hinge Reinforcement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53•Pocket Pivot Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60•Security Hinge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
Mullion (Hardware Removable) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .83Pivots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63, 64Strikes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61, 65, 66, 70Surface Bolt Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .83
Hospital Stops . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100Lead Lined Frames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108Mullion
Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .103Removable Mullion Vertical / Horzontal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .104-105
Pocket Door Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .97-98Rabbet Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49Rescue Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62Rough Buck Frames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .91Security Sidelite Frames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .133Silencers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .127Spats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .99Stainless Steel Frames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25, 26StormPro® 361 Frame Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .125Thermal Break Frames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .101-102Transom Frame Removable Panel Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . .134Wall construction Details
Masonry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
1Flush Masonry KD Miter Corner Joint
FRAME TECHNICAL DATAApril 1, 2002
L
ASSA ABLOY, the global leaderin door opening solutions
#8 SCREW(REQUIRED ON ALL FIRERATED KD FRAMES)
HEAD
JAMB
SPOT WELDS
BREAK–OFF TOOL
JAMB
JAMB
BEND TABS
HEAD
CORNER ASSEMBLY2" (50.8) HEAD
BREAK AWAYCORNER CLIP
2-7/16"(61.9)
1-13/16"(46)
USING THE BREAK-OFF TOOL, BENDCLIP BACK AND FORTH TOWARD OPPOSITE FACE OF FRAME.DO NOT BEND PAST THE OUTSIDE FACE TO AVOID DEFORMING THE FACE.
NOTE: USING PLIERS TO BREAK OFFTHE CORNER CLIP MAY RESULT INDAMAGE TO THE FACE OF FRAME
2Masonry KD 4" Face HeadFRAME TECHNICAL DATAApril 1, 2002
L
ASSA ABLOY, the global leaderin door opening solutions
Masonry KD Double Egress Frame
L
#8 SCREW(REQUIRED ON ALL FIRERATED KD FRAMES)
HEAD FILLERCORNER CLIP
BEND TABS
#8 SCREW(REQUIRED ON ALL FIRERATED KD FRAMES)
BEND TABS
* 5-3/4" (146.1) JAMB DEPTH HAS 7/16" (11.1) RETURN
4-3/4" - 14"(120.6) - (355.6)
1/2"*(12.7)
2-5/8"(66.7)
1-3/8"(34.9)
JAMBDEM
HEADGE 2-5/8"
(66.7)
4-3/4" - 14"(120.6) - (355.6)1/2"*
(12.7)
2"(50.8)
3Masonry KD “G” Profile - Corner Details
FRAME TECHNICAL DATAApril 1, 2002
L
ASSA ABLOY, the global leaderin door opening solutions
JAMBHEAD
CORNER ASSEMBLY
BEND TABS
Masonry KD 2" Face Flush Frame Unequal Rabbet
L1-15/16"(49.2)
VARIES 1-9/16"(39.7)
5/8"(15.9)
2"(50.8)
1/2"(12.7)
M
KD “M” TYPE FLUSHGAUGE - 18 GA. (1.2), 16 GA. (1.4), 14 GA. (1.9)VARIABLE SOFFITJAMB DEPTH 4-1/2" (114.3) THRU 14" (355.6) (1/8"(3.2) INCREMENTS)AVAILABLE WITH 4" (101.6) FACE HEADSNOTE: 5-3/4" (146.1) JAMB DEPTH STANDARD WITH 7/16" (11.1) RETURNSTO PROVIDE 4-7/8" (123.8) THROAT OPENING
#8 SCREW(REQUIRED ON ALL FIRERATED KD FRAMES)
4Masonry 1", 1-1/4", 1-1/2", 1-3/4", Face Flush KD FrameUnequal RabbetFRAME TECHNICAL DATAApril 1, 2002
L
ASSA ABLOY, the global leaderin door opening solutions
1-15/16"(49.2)
VARIES 1-9/16"(39.7)
5/8"(15.9)
1" (25.4), 1-1/4" (31.8)1-1/2" (38.1), 1-3/4" (44.5)
1/2"(12.7)
KD “M” TYPE FLUSHGAUGE - 18 GA. (1.2), 16 GA. (1.4), 14 GA. (1.9)VARIABLE SOFFITJAMB DEPTH 4-1/2" (114.3) THRU 14" (355.6) (1/8"(3.2) INCREMENTS)NOT AVAILABLE WITH 4" (101.6) FACE HEADSNOTE: WHEN CCW MATERIAL IS USED IN CONJUNCTION WITH ABOVE, COORDINATE RABBET AND FACE DIMENSIONS 5-3/4" (146.1) JAMB DEPTH STANDARD WITH7/16" (11.1) RETURNS TO PROVIDE 4-7/8" (123.8) THROAT OPENING.
M
Masonry Flush KD Frame Equal Rabbet
L
VARIES
5/8"(15.9)
1" (25.4), 1-1/4" (31.8)1-1/2" (38.1), 1-3/4" (44.5)
2" (50.8)
1/2"(12.7)
M
1-15/16" (49.2)OR
1-9/16" (39.7)
1-15/16" (49.2)OR
1-9/16" (39.7)
KD “M” TYPE FLUSHGAUGE - 18 GA. (1.2), 16 GA. (1.4), 14 GA. (1.9) VARIABLE SOFFITJAMB DEPTH 4-7/8" (114.3) THRU 14" (355.6) (1/8"(3.2) INCREMENTS)AVAILABLE WITH 4" (101.6) FACE HEADS WITH 2" FACE JAMBS ONLYNOTE: WHEN CCW MATERIAL IS USED IN CONJUNCTION WITH ABOVE, COORDINATE RABBET AND FACE DIMENSIONS. 5-3/4" (146.1) JAMB DEPTH STANDARD WITH7/16" (11.1) RETURNS TO PROVIDE 4-7/8" (123.8) THROAT OPENING.
5Masonry Face Flush KD Frame
Cased Opening FRAME TECHNICAL DATA
April 1, 2002
L
ASSA ABLOY, the global leaderin door opening solutions
VARIES3" (76.2) MINIMUM
1" (25.4)1-1/4" (31.8)1-1/2" (30.1)1-3/4" (44.5)
2" (50.8)
1/2"(12.7)
MK
KD “MK” TYPE FLUSHGAUGE - 18 GA. (1.2), 16 GA. (1.4), 14 GA. (1.9)JAMB DEPTH 3" (76.2) THRU 14" (355.6) (1/8" (3.2) INCREMENTS)NOTE: AVAILABLE WITH 4" (101.6) FACE HEAD WITH 4-1/2" (114.3) MINIMUM JAMB DEPTH 5-3/4" (146.1) JAMB DEPTH STANDARD WITH 7/16" (11.1) RETURNSTO PROVIDE 4-7/8" (123.8) THROAT OPENING.
Masonry Flush KD “G” Profile Frame
L
G
VARIES
2"(50.8)
1/2"(12.7)
1-15/16" (49.2)OR
1-9/16" (39.7)5/8"
(15.9)
2-5/8"(66.7)
KD “G” TYPE FLUSHGAUGE - 18 GA. (1.2), 16 GA. (1.4), 14 GA. (1.9)JAMB DEPTH 3" (76.2) THRU 14" (355.6) (1/8" (3.2) INCREMENTS)MIN. 4" JAMB DEPTH FOR LABELED FRAME WITH 1-15/16" RABBET AND 3-1/4" JAMB DEPTH FOR 1-9/16" RABBET.NOTE: 2" (50.8) AND 2-5/8" (66.7) FACE ON JAMBSAVAILABLE WITH 4" (101.6) FACE HEAD WITH 4-1/2" (114.3) MINIMUM JAMB DEPTH. 5-3/4" (146.1) JAMB DEPTH STANDARD WITH 7/16" (11.1) RETURNSTO PROVIDE 4-7/8" (123.8) THROAT OPENING.
*
* TOTAL DOOR ONLY MAY BE LABELED
6Standard Foot ClipsFRAME TECHNICAL DATAApril 1, 2002
L
ASSA ABLOY, the global leaderin door opening solutions
2" (50.8)STANDARD
2" (50.8)
FACE MINUS 3/8" (9.5)LABEL REQUIREMENTS: FACEMINUS 1/2" (12.7) MAXIMUM
9/32" (7.1) DIA.
P0030STANDARD FOOT CLIP16 GA. (1.4)
P0081DOUBLE EGRESSFOOT CLIPS
P0030C TYPE FRAME
FACE MINUS 3/8" (9.5)LABEL REQUIREMENTS: FACEMINUS 1/2" (12.7) MAXIMUM
P0080G PROFILEJAMB DEPTH 4" (101.6) OR LESS
P0081G PROFILEGREATER THAN 4" (101.6) JAMB DEPTH
P0216 - 16 GA.FOR FACE WIDTH OVER 4"P0281 - 14 GA.P0284 - 12 GA.
7Adjustable Foot Clip
FRAME TECHNICAL DATAApril 1, 2002
L
ASSA ABLOY, the global leaderin door opening solutions
Adjustable Foot Clip - Cased Opening
L
FOOT CLIP SHIPPED LOOSE WITH 2-#12 SHEET METAL SCREWS
ANCHOR PART NUMBER: P0078
5/8" (15.7)3/4" (19.1)
16 GA. (1.4)
1/2" (12.7)
3-5/8" (92)
1/4" (6.4)4-5/8"
(117.5)
PER FACE DIMENSION16 GA. (1.4)
PER JAMB DEPTH
9/32" (7.1) DIA.
5/8" (15.7)3/4" (19.1)
16 GA. (1.4)
1/2" (12.7)
3-5/8" (92)
1/4" (6.4)4-5/8"
(117.5)
PER FACE DIMENSION16 GA. (1.4)
PER JAMB DEPTH
9/32" (7.1) DIA.
FOOT CLIP SHIPPED LOOSE WITH 2-#12 SHEET METAL SCREWS
ANCHOR PART NUMBER: P0151
8Common Walls For Masonry AnchorFRAME TECHNICAL DATAApril 1, 2002
L
ASSA ABLOY, the global leaderin door opening solutions
BUTTED MASONRY-BRICK-TILE OR CONCRETE BLOCK
EXISTING MASONRY OR POURED CONCRETE.
WRAP MASONRY-BRICK-TILE OR CONCRETE BLOCK.
BUTTED MASONRY-BRICK-TILE OR CONCRETE BLOCK.
BUTTED MASONRY-BRICK-TILE OR CONCRETE BLOCK
9Masonry Wire Anchor
FRAME TECHNICAL DATAApril 1, 2002
L
ASSA ABLOY, the global leaderin door opening solutions
Concealed Existing Opening Anchor
L
ANCHOR PART NUMBER: P0098ORDER CODE LOOSE: MW
WIRE DIA. 3/16" (4.8) GALV.ANCHOR MAY BE BENTTO SUIT JAMB DEPTH
9" (228.6)
5-5/8"(142.9)
1-7/8"(47.6)
1-1/16"(27)
COUNTERSINK HOLE FOR3/8" (9.5) F.H. BOLT
9/16" (14.3) DIA.
ANCHOR PART NUMBER: CF004557100 ANCHORS W/PLASTIC PLUG
PLASTIC PLUG PART NUMBER: MS002600100 PLASTIC PLUGS
PLASTIC PLUG
3/4" (19.1) HOLE INCENTER OF SOFFIT
NOT DRILLED BY CURRIES
3/8" (9.5) BOLT & EXPANSION SHELL(NOT PROVIDED)
NOTE: ANCHORS AVAILABLE FOR 5-3/4" (146.1) JAMB DEPTH 2" FACE ONLY AVAILABLE AS SHIP LOOSE PART ONLY
2-1/2"(63.5)
10Masonry “T” AnchorFRAME TECHNICAL DATAApril 1, 2002
L
ASSA ABLOY, the global leaderin door opening solutions
Weld in Type Masonry Anchor
L
ANCHOR PART NUMBER: P0069ORDER CODE LOOSE: M
10-3/4" (273.1)
2" (50.8)
16 GA. (1.4)
ANCHOR PART NUMBER: P0002ORDER CODE LOOSE: MLORDER CODE WELDED: WML
10-3/4" (273.1)
2" (50.8)
16 GA. (1.4)
11EWA Anchor
FRAME TECHNICAL DATANovember, 2004
L
ASSA ABLOY, the global leaderin door opening solutions
FOR STANDARD RABBETED FRAMES 1-15/16" (49.2) X 1-9/16" (39.7)THE EWA ANCHOR IS AVAILABLE IN 5-1/2" (139.7) & 8-1/2" (215.9) SIZES TOFIT 5-3/4" (146.1) & 8-3/4" (222.3) STANDARD RABBETED FRAMES RESPECTIVELY.3/8" FLAT HEAD BOLT RECOMMENDED.
ANCHOR PART NUMBER: P0070ORDER CODE LOOSE: EWAORDER CODE WELDED: WEWA
-AVAILABLE AS SHIP-LOOSE ANCHOR-AVAILABLE FROM WAREHOUSE AS STOCK #CF004896-SPECIFY 5-1/2" (139.7) OR 8-1/2" (215.9) SIZE
1-1/2" MIN. 18, 16, 14 GA. (38.1)
MINIMUM
5-3/4" (146.1)8-3/4" (222.3)
ARCWELD
5-3/4" (146.1)8-3/4" (222.3)
5-1/2" (139.7)8-1/2" (215.9)
2-15/16" (74.6)4-7/16" (112.7)
2-9/16" (65.1)4-1/16" (103.2)
2-9/16"(65.1)
15/16"(23.8)
1"(25.4)
THE EWA ANCHOR MAY BE TRIMMED TO FIT ANY FRAME OF STANDARD RABBET OR SINGLE RABBET 8-3/4" (222.3) OR LESS IN JAMB DEPTHAND EQUAL RABBET 8-3/8" (212.7) OR LESS IN JAMB DEPTH
* 1-1/2" MINIMUM 12 GA.
NOTE: 1-7/8 MIN. STOP WIDTH FOR QM PROFILE
DIAMETER 3/8" (9.5) X 1-3/4" (44.5)EMBEDMENT LENGTH OR STEELEXPANSION SHELL OR 3/8" (9.5)FLATHEAD BOLT
12Pipe Spacer AnchorFRAME TECHNICAL DATAApril 1, 2002
L
ASSA ABLOY, the global leaderin door opening solutions
Spacing Bracket Anchor
L
ANCHOR PART NUMBER: P0044ORDER CODE LOOSE: PSORDER CODE WELDED: WPS
NOTE: FACE DIMENSION FOR PROFILE MUST BE EQUAL
DIAMETER 3/8" (9.5) X 1-3/4" (44.5)EMBEDMENT LENGTH OR STEEL EXPANSION SHELL OR 3/8" (9.5) FLATHEAD BOLT
3/4" I.D.(19.1)
1"(25.4)
1-1/4" (31.7) MIN. 18, 16, 14 GA.*
COUNTERSUNK FLATHEAD BOLT
ARC WELD
ANCHOR PART NUMBER: P0146ORDER CODE LOOSE: SBORDER CODE WELDED: WSB
DIAMETER 3/8" (9.5) X 1-3/4" (44.5)EMBEDMENT LENGTH OR STEEL EXPANSION SHELL OR 3/8" (9.5) FLATHEAD BOLT
1-1/4" (31.7) MIN. 18, 16, 14 GA.*
COUNTERSUNK FLATHEAD BOLT
VARIES
1-13/64"(30.6)
1-13/64"(30.6)
1/2" (12.7) DIA.
16 GA. (1.4)
* 1-1/2" MIN. FOR12 GA.
* 1-1/2" MIN. FOR 12 GA.
13Steel Stud Channel Anchor
FRAME TECHNICAL DATAJuly 15, 2003
L
ASSA ABLOY, the global leaderin door opening solutions
Steel Stud Channel Anchor - Double Egress
ANCHOR PART NUMBER: P0149ORDER CODE LOOSE: SCSLIP IN STEEL STUD ANCHOR“M” & “C” SERIES FRAME
ANCHOR PART NUMBER: P0169ORDER CODE LOOSE: WSCWELD IN STEEL STUD ANCHOR
ANCHOR PART NUMBER: P0149ORDER CODE LOOSE: SCSLIP IN STEEL STUD ANCHOR“M” SERIES FRAME
ANCHOR PART NUMBER: P0169ORDER CODE LOOSE: WSCWELD IN STEEL STUD ANCHOR
1-1/2"(38.1)
5/16"(7.9)
5/16"(7.9)
9/16"(14.3)
NOTE: MINIMUM FACE OF 1-1/4" (31.8) REQUIRED FOR THIS ANCHOR TYPE
3/4"(19.1)
3/8"(9.5)
19/32"(15.1)
5/8"(15.9)
1-11/16"(42.9)
1-1/4"(31.8)
ANCHOR PART NUMBER: P0259ORDER CODE LOOSE: FLUSH SLIP IN STEEL STUD ANCHOR“M” & “C” SERIES FRAME
14Flush Steel Stud AnchorFRAME TECHNICAL DATAJuly 1, 2003
L
ASSA ABLOY, the global leaderin door opening solutions
ANCHOR PART NUMBER: P0243ORDER CODE WELDED: WSCFWELD IN CHANNEL TYPE STEEL STUD ANCHOR (DOUBLE STUD)(SPECIFY STUD SIZE) OR 3/4" DRYWALL CLEARANCE STANDARD.
1-3/16" (30.2)
1-3/16" (30.2)
16 GA. (1.4)
15Wood Stud Anchor
FRAME TECHNICAL DATAApril 1, 2002
L
ASSA ABLOY, the global leaderin door opening solutions
Wood Stud Anchors - Double Egress
L
SLIP IN WOOD STUD ANCHOR - “M” SERIES FRAME ONLYORDER CODE LOOSE: WS “A” DIMENSIONSANCHOR PART NUMBER: P0152 3-1/2" (88.9) STUD(SPECIFY STUD SIZE) P0152 3-5/8" (92.1) STUD
P0152 5-1/2" (139.7) STUDP0152 5-5/8" (142.9) STUD
WELD IN WOOD STUD ANCHOR ORDER CODE LOOSE: WWS “A” DIMENSIONSANCHOR PART NUMBER: P0148 3-1/2" (88.9) STUD(SPECIFY STUD SIZE) P0140 3-5/8" (92.1) STUD
P0142 5-1/2" (139.7) STUDP0144 5-5/8" (142.9) STUD
1" (25.4)
A
9/64" (3.6) DIA.
16 GA. (1.4)
1" (25.4)
A
9/64" (3.6) DIA.
16 GA. (1.4)
1" (25.4)
A
9/64" (3.6) DIA.
16 GA. (1.4)
3-1/4" (82.6)
1" (25.4)
A
9/64" (3.6) DIA.
16 GA. (1.4)
SLIP IN WOOD STUD ANCHOR ORDER CODE LOOSE: WS “A” DIMENSIONSANCHOR PART NUMBER: P0152 3-1/2" (88.9) STUD(SPECIFY STUD SIZE) P0152 3-5/8" (92.1) STUD
P0152 5-1/2" (139.7) STUDP0152 5-5/8" (142.9) STUD
WELD IN WOOD STUD ANCHOR ORDER CODE LOOSE: WWS “A” DIMENSIONSANCHOR PART NUMBER: P0148 3-1/2" (88.9) STUD(SPECIFY STUD SIZE) P0148 3-5/8" (92.1) STUD
P0148 5-1/2" (139.7) STUDP0148 5-5/8" (142.9) STUD
NOTE: SPECIFY JAMB OR HEAD ANCHOR WHEN ORDERING
16Adjustable Multipurpose AnchorFRAME TECHNICAL DATAApril 1, 2006 ASSA ABLOY, the global leader
in door opening solutions
ANCHOR PART NUMBER: P0027ANCHOR CODE: AMP
“A” DIMENSION = JAMB DEPTHS OF 4-3/8" (111.1) THRU 6-3/4" (171.5)2" (50.8) FACE FLUSH “M” SERIES OR DRYWALL “C” SERIESFIELD ADJUSTED TO JAMB DEPTH. AVAILABLE AS SHIP LOOSE PART ONLY
FOR USE AS:WOOD STUD ANCHORWIRE TRUSS ANCHORSTEEL CHANNEL ANCHOR
ANCHOR PART NUMBER: P0045ANCHOR CODE: MP
JAMB DEPTHS OF 4-3/4" (120.7) THRU 9-3/4" (247.6)2" (50.8) FACE FLUSH “M” SERIES OR DRYWALL “C” SERIES
Multipurpose Anchor
L
#12-24 X 1/2" (12.7)SLOTTED HEX WASHER HEAD
1/8" (3.2) DIA.
16 GA. (1.4)
A
BEND OR TRIM LEGS TO SUIT WALL CONDITIONS
BEND OR TRIM LEGS TO SUIT WALL CONDITIONS
NUMBER OF STIFFENERSDEPEND ON JAMB DEPTHS
5/32" (4) DIA.
18 GA. (1.4)
UNEQUAL RABBETS ONLY ON MASONRY WALLS
17Multi-Purpose Anchor Installation - Drywall Return Frame
FRAME TECHNICAL DATANovember, 2004
L
ASSA ABLOY, the global leaderin door opening solutions
2. INSERT ANCHOR INTO FRAME THROAT TILTED AT APPROXIMATELYA 50˚ ANGLE AS SHOWN IN DETAIL “B”.
3. THE ANCHOR MUST ALSO BE INSERTED AT APPROXIMATELYA 20˚ ANGLE FROM THE RABBETS OF THE FRAME AS SHOWN IN DETAIL “B”. THE FLANGES ON THE ANCHOR MUST CLEAR THE BACKBEND RETURNS.
4. TWIST THE ANCHOR INTO PLACE BY APPLYING PRESSURE IN THE OPPOSITE DIRECTIONS TO EACH SIDE OF THE ANCHOR AS SHOWNIN DETAIL “C”.
5. ONCE THE ANCHOR HAS SNAPPED INTO PLACE, DETAIL “D”, TURN IT UP INTO THE CORRECT POSITION AS SHOWN IN DETAIL “E” LEGS SHOULD BE BENT BACK TO THE ORIGINAL POSITION IF NECESSARY.
1. BEND LEGS OF ANCHOR 90˚ AS SHOWN IN DETAIL “A” (LEGS MAY HAVE TO BE BENT FURTHER IN LATER STEPS).
DETAIL “A”
DETAIL “B”
DETAIL “C”
DETAIL “D”
DETAIL “E”
50˚
20˚
PUSH
PUSH LIFT UP
P0045
18Ceiling Strut AnchorFRAME TECHNICAL DATASeptember 1, 2005
L
ASSA ABLOY, the global leaderin door opening solutions
Mullion Stirrup Anchor
L
ANCHOR PART NUMBER: P01594" (101.6)
1" (25.4)
3/8" (9.5) DIA.2 PLS.
VARIES
1/4" (6.4)
STRUT1/4" (6.4) X 1" (25.4) STEEL BAR1 REQ’D
WEDGES
1/4" (6.4)1/16" (1.6)
1-1/4" (31.8)WEDGE
1-1/8" (28.6)
VARIES
STRUT GUIDE16 GA. (1.4)
2 REQ’D
1-1/8" (28.6)
1-9/16" (39.7)
ANCHOR PART NUMBER: P0089
DIMENSION “B” VARIES WITH FACE DIMENSION2" (50.8) FACE MULLION “B” EQUALS 1-1/2" (38.1)
B9/32" (7.1) DIA.
1-1/2" (38.1)
VARIES WITHJAMB DEPTH
12 GA. (2.6)FIELD INSTALL #8 SMSMINIMUM EACH FACE
19Full Weld KD
FRAME TECHNICAL DATAApril 1, 2002
L
ASSA ABLOY, the global leaderin door opening solutions
CONTINUOUS WELD FACE SEAMGRIND AND FINISH SMOOTH
CONTINUOUS WELD JOINTSOF RABBET AND SOFFIT
WELD CODE FW
20Seam Weld Flush KD FRAME TECHNICAL DATAApril 1, 2002 ASSA ABLOY, the global leader
in door opening solutions
L
Saw Miter Weld
L
BEND TABS
CONTINUOUS WELD FACE SEAMGRIND AND FINISH SMOOTH
CONTINUOUS WELD INSIDE OF MITER
GRIND FACE AND FINISH SMOOTH
WELD CODE SW (KD)
GRIND FACE AND FINISH SMOOTH
TACK WELD RABBETAND SOFFIT
WELD CODE SMWWELD CODE SMT
21Saw Butt Weld
FRAME TECHNICAL DATAApril 1, 2002
L
ASSA ABLOY, the global leaderin door opening solutions
WELD CODE BEW (<3) WELD CODE BET (<3)
WELD CODE SBW (>3) WELD CODE SBT (>3)
22Corner WeldsFRAME TECHNICAL DATAJuly 1, 2003
L
ASSA ABLOY, the global leaderin door opening solutions
WELD CODE BEF 10
23Splice Joints
FRAME TECHNICAL DATAApril 1, 2002
L
ASSA ABLOY, the global leaderin door opening solutions
Saw Miter Only
LNOTE: PREPARED FOR DISTRIBUTOR WELDING
WELD CODE FSP WELD CODE WSP
WELD CODE SMO
WELD CODE EBE
EXACTNO NOTCH
WELD CODE SBE
EXACTNOTCH TOP JAMBSNOTCH BOTH ENDS.(BLANK OR HEADS)
NOTE: FACTORY WELDEDFRAMES EXCEEDING 9' X 14'WILL BE PROVIDED WITHFIELD SPLICES
24Field Splice FramesFRAME TECHNICAL DATAApril 1, 2002 ASSA ABLOY, the global leader
in door opening solutions
FRAMES FACTORY WELDED AT CURRIES:
PROVIDE FIELD SPLICES FOR FRAMES THAT EXCEED OVERALL SIZE SHOWN.
FRAMES FACTORY WELDED AT REGIONAL SERVICE CENTERS:
14'0"(4267)WIDTH
9'0" (2743)HEIGHT
9'0" (2743)WIDTH
14'0"(4267)HEIGHT
14'0"(4267)WIDTH
8'0" (2438)HEIGHT
8'0" (2438)WIDTH
14'0"(4267)HEIGHT
25Saw Butt Weld Stainless Steel
FRAME TECHNICAL DATAApril 1, 2002ASSA ABLOY, the global leader
in door opening solutions
L
JAMB DEPTH+1/8" (3.2)
THROAT OPENING1" (25.4) LESS THANJAMB DEPTH
RETURN FILLERS
BACKWELD SEAM
1/8" (3.2)
JAMBHEAD
304 STAINLESS STEEL#4 FINISH SATIN GRAIN
THROAT OPENING1" (25.4) LESS THANJAMB DEPTH
JAMB DEPTH -1/8" (3.2)
NOTE: HEAD IS RECESSED 1/8" (3.2)WITH HAIRLINE SEAM EXPOSED
NOTE: GRAIN PATTERN IS VERTICAL ON HORIZONTALFRAME MEMBERS UNDER 4' (1219.2) LONG,OVER 4' (1219.2) LONG, GRAIN PATTERN IS HORIZONTAL
26Stainless Steel Sidelight FrameFRAME TECHNICAL DATAApril 1, 2002 ASSA ABLOY, the global leader
in door opening solutions
L
NOTE: HEAD IS RECESSED 1/8" (3.2)WITH HAIRLINE SEAM EXPOSED
NOTE: #1 GRAIN PATTERN IS VERTICAL ON HORIZONTAL MEMBERS UNDER 4' (1219.2) LONG#2 OVER 4' (1219.2) LONG, GRAIN PATTERN IS HORIZONTAL
NOTE: VERTICAL MEMBERS MUST RUN FULL HEIGHT
HORIZONTAL MEMBERSUNDERSIZED 1/8" (3.2)
VERTICAL MEMBERSOVERSIZED 1/8" (3.2)
304 STAINLESS STEEL#4 FINISH SATIN GRAIN
#1 #2
3' (914.4) 6' (1828.8)
JAMB DEPTH + 1/8" (3.2)
1/8" (3.2)
WELDEDJAMB DEPTH - 1/8" (3.2)
27Half Sidelight Window Option
FRAME TECHNICAL DATAJuly 15, 2003ASSA ABLOY, the global leader
in door opening solutions
OPTION BMOST COMMON
REMOVE BACKSIDEOF MULLION
L
OPTION AAS REQUIRED
L
SPLICE WELD SECTION TO MULLIONFILL AND GROUND SMOOTH,LABELED WHEN FULLY WELDED.
OPTION CAS REQUIRED
L
FILLER PLATEWITH STOP
NOTE: MAY BE LABELED WHENPROPERLY WELDED.
EXPOSED SEAMUNLESS FACTORYWELDED SEAM
28Cut and Notch OptionsFRAME TECHNICAL DATAApril 1, 2002 ASSA ABLOY, the global leader
in door opening solutions
L
CORNER: KD STANDARD WHEN POSSIBLEMUST MEET KD PARAMETERS
SAW MITER:* IF FACES OF HEAD AND JAMB ARE EQUAL
1. EXCEPT: 4" (101.6) FACE HEAD TO2" (50.8) FACE JAMB
BUTT END:* IF FACES ARE UNEQUAL
* SMO OR SBE MUST BE NOTED IN CONSTRUCTION COLUMN.
NOTE: MAY BE LABELED WHEN PROPERLY WELDED
NOTE: MAY BE LABELED WHEN FACE WELDED
SAW MITER
BUTT END
KD
29Cut and Notch Options
FRAME TECHNICAL DATAApril 1, 2002ASSA ABLOY, the global leader
in door opening solutions
L
STRIKE MULLION: NOTCH TOPEXCEPTION: WILL RUN THROUGH HEAD IF HEAD PROFILE IS
DIFFERENT ON GLASS SIDEEXAMPLE: “M” PROFILE AT DOOR OPENING
“G” PROFILE AT WINDOW SIDERUN MULLION THROUGH IF HEAD FACES ARE DIFFERENT FROM DOOR SIDE TO GLASS SIDEOR IF FIELD SPLICE IS REQUIRED
NOTE: MAY BE LABELED WHEN PROPERLY WELDED
NOTE: PROVIDES ACCESS FOR ELECTRICALCONDUIT OR GROUT
30Cut and Notch OptionsFRAME TECHNICAL DATAApril 1, 2002 ASSA ABLOY, the global leader
in door opening solutions
L
HORIZONTAL MULLION: NOTCH BOTH ENDS TO BUTTBETWEEN VERTICAL MEMBERSIS STANDARD PREPARATION
NOTE: MAY BE LABELED WHEN PROPERLY WELDED
NOTCH STOP OFJAMB TO RECEIVE MULLION
TYPICAL REMOVABLEMULLION PREPARATION
OPTIONAL STANDARD
31Cut and Notch Options
FRAME TECHNICAL DATAApril 1, 2002ASSA ABLOY, the global leader
in door opening solutions
L
MULLION:NOTCH TOP AND BOTTOM, WILLRUN THROUGH FROM HEAD TOTOP OF SILL
1. EXCEPTION: WILL RUN MULLIONTHROUGH TO FLOOR RATHER THANSPLICE 2 SECTIONS OF SILL TOGETHER
2. EXCEPTION: RUN MULLION THROUGH HEAD AND SILL IF FIELD SPLICEIS REQUIRED
NOTE: MAY BY LABELED WHEN PROPERLY WELDED
SILLS:NOTCH BOTH ENDS TO BUTT BETWEENVERTICAL MEMBERS
OPTIONALSTANDARD STANDARD
32Saw Butt EndFRAME TECHNICAL DATAApril 1, 2002 ASSA ABLOY, the global leader
in door opening solutions
L
Drywall KD “CG” Profile Corner Details
NOTE: MAY BE LABELED WHEN PROPERLY WELDED
#8 SCREW(REQUIRED ON ALL FIRE RATED FRAMES)
L
WALL NOTCH JAMB FOR DRYWALL WALL CONSTRUCTION
OPTIONAL STANDARD
33Drywall KD Frame Corner Clip Detail
FRAME TECHNICAL DATAApril 1, 2002ASSA ABLOY, the global leader
in door opening solutions
L
3-1/2" (88.9)
JAMB
HEAD2" FACE
2-3/8" (60.3)
2-3/8" (60.3)
#8 SCREW(REQUIRED ON ALLFIRE RATED FRAMES)
HEAD2" (50.8) FACE
SPOT WELDSBY CURRIES
*RETURN FILLER: P0071
HEAD4" (101.6) FACE
JAMB
WELDPROJECTIONS
C PROFILE CORNER
34Security AnchorFRAME TECHNICAL DATAApril 1, 2002 ASSA ABLOY, the global leader
in door opening solutions
L
Drywall Frame Compression Anchor
L
COMPRESSIONANCHOR
SECURITYANCHOR
45" (1143) TYPICAL
BOTTOM OF FRAME
PER JAMBDEPTH
VARIES
1-1/8" (28.6)
1-1/8" (28.6)
3-1/2" (88.9)16 GA. (1.4)
ANCHOR PART NUMBER: P0028
5/8" (15.8)MAXIMUM TRAVEL
ANCHOR PART NUMBER: P0026 (2" FACE)ANCHOR PART NUMBER: P0018 (1-1/2" TO 1-3/4" FACE)
COMPRESSIONANCHOR
3-1/2" (88.9)1" (25.4)MIN.
35Drywall KD Frame Standard Base Anchor
FRAME TECHNICAL DATANovember, 2004ASSA ABLOY, the global leader
in door opening solutions
L
Drywall KD Frame Optional Base Anchor
L
3/4" (19.1)
5/8" (15.9)
2" (50.8)
ANCHOR HOLESCOUNTERSUNK
#6 SCREWBOTH SIDES
3-1/4" (82.6)
1" (25.4)
7/8" (22.2)
1/2" (12.7)
1/2" (12.7)
3/16" (4.8) DIA.
16 GA. (1.4)
ANCHOR PART NUMBER: P0087
NOTE: REQUIRED ON 1-1/2" (38.1), 1-3/4" (44.5) FACE DRYWALL FRAMES. 3", 3-1/8", 3-1/4", JAMB DEPTHS.
2" FACEONLY
3/4" (19)
FLOOR
CL
MINIMUM JAMB DEPTH 3-3/8 (85.7)
36Drywall CG ProfilesFRAME TECHNICAL DATAApril 1, 2002 ASSA ABLOY, the global leader
in door opening solutions
L
Compression Anchor System Narrow Jamb Depth
L
3" (76.2) – 14" (355.6)
VARIES1-15/16" (49.2)
OR1-9/16" (39.7)
JAMB DEPTHS
2-5/8" (66.7)2" (50.8)
5/8" (25.9)
1/2" (12.7)
3/8" (9.5)
1/2" (12.7)
3/8" (9.5)
GAUGE - 18 GA. (1.2), 16 GA. (1.4)NOTE: AVAILABLE WITH 4" (101.6) FACE HEAD WITH 4-1/2" (114.3) MINIMUM JAMB DEPTH
CG PROFILE *1-3/8" (34.9) DOOR - 3" (76.2) JAMB DEPTH1-3/4" (44.5) DOOR - 3" (76.2), 3-1/8" (79.4), 3-1/4" (82.6), 3-3/8" (85.7) JAMB DEPTH
ROUGH OPENING WIDTHEQUALS NOMINAL DOOROPENING: PLUS 2-13/16" (71.4)
ROUGH OPENING HEIGHTEQUALS NOMINAL DOOROPENING: PLUS 3/4" - 1" MAX
(19.1) - (25.4)
STRAP BASE ANCHOR
3/4" (19.1)
-COMPRESSION ANCHORS 3-1/2" (88.9)CL
STROKE
* “CG” PROFILE JAMB DEPTHS NOT LISTED ABOVE USE STD. DRYWALL ROUGH OPENING DIMENSIONS
CG
37Drywall KD Frame Unequal Rabbet
FRAME TECHNICAL DATAApril 1, 2002ASSA ABLOY, the global leader
in door opening solutions
L
Drywall KD Frame Equal Rabbet
L
1-1/2" (38.1)1-3/4" (44.5)
2" (50.8)
5/8" (15.9)
1-15/16"(49.2)
1-9/16"(39.7)
VARIES
3/8" (9.5)
1/2"(12.7)
KD DRYWALLGAUGE - 18 GA. (1.2), 16 GA. (1.4), 14 GA. (1.9) *UNEQUAL RABBETJAMB DEPTH 4-1/2" (114.3) THRU 14" (355.6) (1/8" (3.2) INCREMENTS)2" (50.8) FACE AVAILABLE WITH 4" (101.6) HEADSNOTE: 14 GA. AVAILABLE WITH 2" (50.8) FACE ONLY
1-1/2" (38.1)1-3/4" (44.5)
2" (50.8)
5/8" (15.9)
1-15/16" (49.2)OR
1-9/16" (39.7)VARIES
3/8" (9.5)
1/2"(12.7)
1-15/16" (49.2)OR
1-9/16" (39.7)OR OR
C
C
KD DRYWALLGAUGE - 18 GA. (1.2), 16 GA. (1.4), 14 GA. (1.9) *UNEQUAL RABBETJAMB DEPTH 4-7/8" (123.8) THRU 14" (355.6) (1/8" (3.2) INCREMENTS)2" (50.8) FACE AVAILABLE WITH 4" (101.6) HEADSAVAILABLE IN COMMUNICATING FRAMESNOTE: 14 GA. AVAILABLE WITH 2" (50.8) FACE ONLY
38Drywall KD Frame Cased OpeningFRAME TECHNICAL DATAApril 1, 2002 ASSA ABLOY, the global leader
in door opening solutions
L
Drywall KD “CG” Profile Frame
L
VARIES3" (76.2) MINIMUM
1-1/2" (38.1)1-3/4" (44.45)
2" (50.8)
3/8" (9.5)
1/2" (12.7)
KD DRYWALLGAUGE - 18 GA. (1.2), 16 GA. (1.4), 14 GA. (1.9)JAMB DEPTH 3" (76.2) THRU 14" (355.6) (1/8" (3.2) INCREMENTS)14 GA. AVAILABLE W/2" FACE ONLY
NOTE: AVAILABLE WITH 4" (101.6) FACE HEAD WITH 4-1/2" (114.3) MINIMUM JAMB DEPTHWITH 2" FACE JAMBS ONLY.
VARIES
2" (50.8)
3/8" (9.5)
1/2" (12.7)
1-15/16" (49.2)
1-9/16" (39.7)OR
5/8" (50.8)
2-5/8" (66.7)
KD “CG” PROFILE DRYWALLGAUGE - 18 GA. (1.2), 16 GA. (1.4)JAMB DEPTH 3" (76.2) THRU 14" (355.6) (1/8" (3.2) INCREMENTS)NOTE: 2" (50.8) AND 2-5/8" (66.7) FACE ONLY
CK
CG
39Drywall Cased Opening Compression Anchor
FRAME TECHNICAL DATANovember, 2004ASSA ABLOY, the global leader
in door opening solutions
L
CM Profile Frames
L
2" (50.8) LEG
STIFFENER PART NUMBER: P0093
16 GA. (1.4)
VARIES2" (50.8)
3/4" (19.1)
NOTE: STIFFENER ADDED TO PREVENT DISTORTION OF FRAME WHEN TIGHTENING ANCHOR
FOOTCLIPS
CM 3-1/2" (88.9) - 14" (355.6)CMG 3" (76.2) - 14" (355.6)
2" (50.8) CM CMG
CM PROFILE FRAMES DO NOT HAVE THE COMPRESSION BARNOR BASE ANCHORS. THEY DO HAVE FOOTCLIPS WELDED INAND ARE FURNISHED WITH LOOSE M.P. OR WIRE ANCHOR.WELDED IN ANCHORS ARE OPTIONAL. SAME K.D. CORNERCAPABILITIES AS THE C FRAME. THESE FRAME PROFILES ARE TO BE WELDED CORNER CONSTRUCTION WHEN INSTALLED.
* MAY BE LABEL APPROVED WITH PROPERLY WELDED FRAME CORNERS.
40Drywall KD Frame (“C” Profile) Installation InstructionsFRAME TECHNICAL DATASeptember, 2006 ASSA ABLOY, the global leader
in door opening solutions
3
4
2
57 6 7
8
9
1. CONSTRUCT WALL WITH ROUGH OPENING HEIGHT EQUAL TO FINISHED OPENING HEIGHT PLUS 3/4" (19.1) TO 1" (25.4)MAX., ROUGH OPENING WIDTH IS AS FOLLOWS:A) FOR 2" (50.8) FACE FRAMES-OPENING WIDTH PLUS 2-1/8" (54.0) TO 2-3/8" (60.3)B) FOR 1-3/4" (44.5) AND 1-1/2" (38.1) FACE FRAMES-OPENING WIDTH PLUS 2" (50.8)C) FOR “C” AND “CG” PROFILES, 3" (76.2) JAMB DEPTH 1-9/16" (39.7) RABBET AND 3" (76.2), 3-1/8" (79.4),
3-1/4" (82.6) AND 3-3/8" (85.7) JAMB DEPTH 1-15/16" (49.2) RABBET FRAMES-OPENING WIDTH PLUS2-13/16" (71.4), ALL OTHER “C” AND “CG” PROFILE FRAMES-OPENING WIDTH PLUS 2-1/8" (54.0) TO2-3/8" (60.3)
d) FOR 2" (508) FACE CASED OPENING - OPENING WIDTH PLUS 2-1/4" (572)
2. IF WRAP-AROUND BASE ANCHOR IS USED, NOTCH DRYWALL IN THAT AREA.
3. RETRACT COMPRESSION BARS IN THE JAMBS AND INSTALL ONE JAMB IN POSITION ON WALL.
4. INSERT FRAME HEAD UNDER THE CORNER CLIPS OF THE JAMB AND RAISE INTO POSITION.
5. INSERT THE CORNER CLIPS OF THE REMAINING JAMB INTO THE OPPOSITE END OF THE HEAD AND POSITION JAMB ON WALL.
6. LOCATE A REMOVABLE FRAME SPACING BAR AT BASE OF CENTERED FRAME TO MAINTAIN PROPER OPENING WIDTH DURING INSTALLATION.
7. SQUARE AND PLUMB FRAME AND INSTALL BASE ANCHOR SCREWS THROUGH COUNTERSINK HOLES IN FRAME FACE AND INTO FLOOR PLATE.
8. SQUARE TOP OF FRAME AND TIGHTEN COMPRESSION BARS. (DO NOT OVER TIGHTEN).
9. INSTALL (4) NO. 8 X 1/2" (12.7) SHEET METAL SCREWS AT THE CORNERS OF THE HEAD TO ATTACH HEAD TO JAMBS (REQUIRED FOR FIRE RATED FRAMES).
L
ASSA ABLOY, the global leaderin door opening solutions
41Drywall KD Borrowed Lite
FRAME TECHNICAL DATAJuly, 2007
L
OVERALL FRAMEWIDTH
NOTE A: ROUGH OPENING HEIGHT FOR 2" (50.8) FACE FRAMES EQUALSGLASS OPENING SIZE PLUS 2-1/2" (63.5) INCLUDING CASED OPENINGNOTE A: ROUGH OPENING HEIGHT FOR 1-1/2" (38.1) & 1-3/4" (44.5) FACE FRAMESEQUALS GLASS OPENING SIZE PLUS 2" (50.8)
NOTE B: ROUGH OPENING WIDTH FOR 2" (50.8) FACE FRAMES EQUALSGLASS OPENING SIZE PLUS 2-1/2" (63.5) INCLUDING CASED OPENINGROUGH OPENING WIDTH FOR 1-1/2" (38.1) & 1-3/4" (44.5) FACE FRAMESEQUALS GLASS OPENING SIZE PLUS 2" (50.8)
NOTE:5/8" (15.8) X 5/8" (15.8) GLASS STOPSARE PUNCHED AND CUT TO LENGTH REMOVABLE STOPS MATCH FIXED STOPLENGTH AND ARE SHIPPED LOOSE
KD BORROWED LITE (DRYWALL FRAME ONLY)ORDER OF INSTALLATION - A) PLACE RIGHT SIDE VERTICAL JAMB MEMBER INTO OPENING; B) INSTALL SILLMEMBER AND ASSEMBLE CORNER #1; C) THEN INSTALL HEAD MEMBER AND ASSEMBLE CORNER #2 D) WHILEINSTALLING THE REMAINING LEFT VERTICAL JAMB MEMBER IT MAY BE NECESSARY TO EXTEND THE HEAD(CORNER #3) AND SILL (CORNER #4) TO THEIR ROUGH OPENING LIMITATIONS FOR EASIER INSTALLATION; E)THEN ASSEMBLE CORNER #3 AND FINALLY SNAP INTO POSITION THE REMAINING CORNER #4; F) INSTALLSCREWS THROUGH FRAME RETURNS INTO CORNER CLIPS; G) ADJUST COMPRESSION BARS UNTIL LEVEL ANDPLUMB.
GLASS OPENING1'6" (457.2) MINIMUM
ROUGH OPENINGHEIGHT
SEE NOTE A
OVERALL FRAMEHEIGHT
GLASSOPENING
VARIABLEFACE
ROUGH OPENING WIDTHSEE NOTE B
CL
CL
COMP.BAR
STD.
CL
CL
COMP.BAR
STD.
33
44 1
1
22
4" (101.6) FACE HEADS & SILLSARE NOT AVAILABLE.
“CG” PROFILE - SEE NEXT PAGE
VARIABLEFACE
ASSA ABLOY, the global leaderin door opening solutions
42Single Rabbet Drywall KD Borrowed LiteFRAME TECHNICAL DATAJuly, 2007
An ASSA ABLOY Group company ASSA ABLOY
L
OVERALL FRAMEWIDTH
“CG” PROFILE - COMPRESSION BAR RABBET MOUNTED.JAMB DEPTHS INCLUDE 3" (76.2), 3-1/8" (79.4), 3-1/4" (82.5), 3-3/8" (85.7) X 1-15/16" (49.2) RABBETAND 3" (76.2) X 1-9/16" (39.7) RABBET
NOTE A: ROUGH OPENING HEIGHT FOR 2" (50.8) FACE FRAMES EQUALSGLASS OPENING SIZE PLUS 2-3/4" (69.8)
NOTE B: ROUGH OPENING WIDTH FOR 2" (50.8) FACE FRAMES EQUALSGLASS OPENING SIZE PLUS 2-1/2" (63.5)
KD BORROWED LITE (DRYWALL FRAME ONLY)ORDER OF INSTALLATION - A) PLACE RIGHT SIDE VERTICAL JAMB MEMBER INTO OPENING; B) INSTALL SILLMEMBER AND ASSEMBLE CORNER #1; C) THEN INSTALL HEAD MEMBER AND ASSEMBLE CORNER #2 D) WHILEINSTALLING THE REMAINING LEFT VERTICAL JAMB MEMBER IT MAY BE NECESSARY TO EXTEND THE HEAD(CORNER #3) AND SILL (CORNER #4) TO THEIR ROUGH OPENING LIMITATIONS FOR EASIER INSTALLATION; E)THEN ASSEMBLE CORNER #3 AND FINALLY SNAP INTO POSITION THE REMAINING CORNER #4; F) INSTALLSCREWS THROUGH FRAME RETURNS INTO CORNER CLIPS. G) ADJUST COMPRESSION BARS UNTIL LEVEL ANDPLUMB.
GLASS OPENING1'6" (457.2) MINIMUM
HEIGHTWIDTH
SEE NOTE A
OVERALL FRAMEHEIGHT
GLASSOPENING
VARIABLEFACE
ROUGH OPENING WIDTHSEE NOTE B
CL
CL
COMP.BAR
CL
CL
COMP.BAR
33
44 1
1
22
4"(101.6)
4"(101.6) #8 SHEET
METAL SCREW(8 PLACES)
VARIABLEFACE
43Throat Filler for Drywall Frames
FRAME TECHNICAL DATAApril 1, 2002ASSA ABLOY, the global leader
in door opening solutions
L
INSTALLATION
1. FOR BEST RESULTS INSTALL FRAME IN OPENINGFIRST. DO NOT TIGHTEN COMPRESSION ANCHORS.
2. CUT JAMB FILLER STRIPS TO OVERALL LENGTHOF JAMB BACKBEND. CUT HEAD FILLER STRIP1" (25.4) UNDER OVERALL LENGTH OF HEAD BACKBEND.
3. REMOVE PROTECTIVE FILM FROM ADHESIVE TAPEAND APPLY FILLER STRIPS TO FRAME BACKBENDSWITH 1/8" (3.2) THICK LEG BETWEEN BACKBENDRETURN AND WALL. APPLY PRESSURE TO SEAT FIRMLY.
4. SQUARE FRAME, TIGHTEN COMPRESSION ANCHORS, INSTALL BASE ANCHORS AND RESEAT FILLERSTRIPS IF NECESSARY.
FILLER EQUALS OVERALL LENGTH OF BACKBEND
1/2"(12.7)
1/2"(12.7)LENGTH OF
HEAD FILLER
OVERALL LENGTH OF HEAD BACKBEND
THROAT FILLER STRIPS ARE MADE OF WHITE RIGID PVC WITH RESILIENT DOUBLE FACE TAPE FOR APPLICATION TO THEFRAME BACKBEND OR AFTER THE FRAME HAS BEEN INSTALLED.
SUPPLIED IN LENGTHS OF 7 FT. 3 IN. (2209.8) TO ACCOMMODATE MOST JAMB HEIGHTS WITH A CONTINUOUS STRIP.
NOTE: THROAT FILLER IS NOT ALLOWED ON LABEL FRAMES
THROAT REDUCEDBY 1/8" (3.2)
ONE FILLER STRIP
THROAT REDUCEDBY 1/4" (6.4)
TWO FILLER STRIPS
1/8" (3.2)DOUBLE FACE TAPE
FULL SIZE
44CURRIES Standard Hinge & Strike Locations for 1-3/4" FramesFRAME TECHNICAL DATAApril 1, 2002 ASSA ABLOY, the global leader
in door opening solutions
L
* STRIKE BACKSET: 5/16" (7.9) FOR 1-3/4" (44.5) DOOR1/2" (12.7) FOR 2" (50.8) DOOR
CL
CL
CL
CL
A
B
B
C
40" (1016) STANDARD
HINGE SIZE MAY VARY LOCATION REMAINS THE SAME.HINGE BACKSET: 5/16" (7.9) FOR 1-3/4" (44.5) DOOR.
5/8" (15.9) FOR 2" (50.8) DOORDOOR RABBETS: 1-15/16" (49.2) FOR 1-3/4" (44.5) DOOR.
2-3/16" (55.6) FOR 2" (50.8) DOOR.
FOR USE WITH THREE HINGES4-1/2" (114.3) OR 5" (127)
*
4-7/8" (123.8)STRIKE
SIZE A B C6’8” (2032) 7-1/4” (184.2) 30-1/4” (768.4) 12-1/4” (311.2)
6’10” (2082.8) 7-1/4” (184.2) 31-1/4” (793.8) 12-1/4” (311.2)7’0” (2133.6) 7-1/4” (184.2) 32-1/4” (819.2) 12-1/4” (311.2)7’2” (2184.4) 7-1/4” (184.2) 33-1/4” (844.6) 12-1/4” (311.2)7’10” (2387.6) 7-1/4” (184.2) 37-1/4” (946.2) 12-1/4” (311.2)8’0” (2438.4) 7-1/4” (184.2) 38-1/4” (971.6) 12-1/4” (311.2)
LLLLL
CL
45CURRIES Standard Hinge & Strike Locations for 1-3/4" Frames
FRAME TECHNICAL DATAApril 1, 2002ASSA ABLOY, the global leader
in door opening solutions
LSIZE A B C
6'8" (2032) 7-1/4" (184.2) 20-1/8" (511.2) 12-3/8" (314.3)6'10" (2082.8) 7-1/4" (184.2) 20-7/8" (530.2) 12-1/8" (308)7'0" (2133.6) 7-1/4" (184.2) 21-1/2" (546.1) 12-1/4" (311.2)7'2" (2184.4) 7-1/4" (184.2) 22-1/8" (562) 12-3/8" (314.3)7'10" (2387.6) 7-1/4" (184.2) 24-7/8" (631.8) 12-1/8" (308)8'0" (2438.4) 7-1/4" (184.2) 25-1/2" (647.7) 12-1/4" (311.2)9'0" (2743.2) 7-1/4" (184.2) 29-1/2" (749.3) 12-1/4" (311.2)10'0" (3048) 7-1/4" (184.2) 33-1/2" (850.9) 12-1/4" (311.2)
LLLLLLL
* STRIKE BACKSET: 5/16" (7.9) FOR 1-3/4" (44.5) DOOR1/2" (12.7) FOR 2" (50.8) DOOR
CL
CL
CL
CL
CL
A
B
B
C
40" (1016) STANDARD
HINGE SIZE MAY VARY LOCATION REMAINS THE SAME.HINGE BACKSET: 5/16" (7.9) FOR 1-3/4" (44.5) DOOR.
5/8" (15.9) FOR 2" (50.8) DOORDOOR RABBETS: 1-15/16" (49.2) FOR 1-3/4" (44.5) DOOR.
2-3/16" (55.6) FOR 2" (50.8) DOOR.
FOR USE WITH FOUR HINGES4-1/2" (114.3) OR 5" (127)
*
4-7/8" (123.8)STRIKE
B
CL
46CURRIES Standard Hinge & Strike Locations for 1-3/8" FramesFRAME TECHNICAL DATAApril 1, 2002 ASSA ABLOY, the global leader
in door opening solutions
LSIZE A B C
6'8" (2032) 9-3/4" (247.7) 59-7/8" (1520.8) 10-3/8" (263.5)6'10" (2082.8) 9-3/4" (247.7) 61-7/8" (1571.6) 10-3/8" (263.5)7'0" (2133.6) 9-3/4" (247.7) 63-7/8" (1622.4) 10-3/8" (263.5)7'2" (2184.4) 9-3/4" (247.7) 65-7/8" (1673.2) 10-3/8" (263.5)
CL
CL
CL
A
B
C
40-5/16" (1023.9) STANDARD
HINGE BACKSET: 5/16" (7.9)
FOR USE WITH TWO HINGES 1-3/8" (34.9) DOOR3-1/2" (88.9) OR 4" (101.6)
STRIKE BACKSET 3/16" (4.8)
2-3/4" (69.9)
STRIKE
LLL
HINGE SIZE MAY VARY, LOCATION REMAINS THE SAME.CL
47CURRIES Standard Hinge & Strike Locations for 1-3/8" Frame
FRAME TECHNICAL DATAApril 1, 2002ASSA ABLOY, the global leader
in door opening solutions
LL
SIZE A B C6'8" (2032) 9-3/4" (247.7) 29-15/16" (760.4) 10-3/8" (263.5)6'10" (2082.8) 9-3/4" (247.7) 30-15/16" (785.8) 10-3/8" (263.5)7'0" (2133.6) 9-3/4" (247.7) 31-15/16" (811.2) 10-3/8" (263.5)7'2" (2184.4) 9-3/4" (247.7) 32-15/16" (836.6) 10-3/8" (263.5)
CL
CL
CL CL
A
B
C
40-5/16" (1023.9) STANDARD
HINGE BACKSET: 5/16" (7.9)
FOR USE WITH THREE HINGES 1-3/8" (34.9) DOOR3-1/2" (88.9) OR 4" (101.6)
STRIKE BACKSET 3/16" (4.8)
2-3/4" (69.9)
STRIKE
LLL
B
HINGE SIZE MAY VARY, LOCATION REMAINS THE SAME.CL
48CURRIES Standard Hinge & Strike Locations for 1-3/4" Dutch FrameFRAME TECHNICAL DATANovember, 2004 ASSA ABLOY, the global leader
in door opening solutions
L
LSIZE A B C D E
6'8" (2032) 7-1/4" (184.2) 24-1/4" (616) 13-1/2" (342.9) 22-3/4" (577.9) 12-1/4" (311.2)6'10" (2082.8) 7-1/4" (184.2) 26-1/4" (666.6) 13-1/2" (342.9) 22-3/4" (577.9) 12-1/4" (311.2)7'0" (2133.6) 7-1/4" (184.2) 28-1/4" (717.6) 13-1/2" (342.9) 22-3/4" (577.9) 12-1/4" (311.2)7'2" (2184.4) 7-1/4" (184.2) 30-1/4" (768.4) 13-1/2" (342.9) 22-3/4" (577.9) 12-1/4" (311.2)7'10" (2387.6) 7-1/4" (184.2) 35-1/4" (895.4) 16-1/2" (419.1) 22-3/4" (577.9) 12-1/4" (311.2)8'0" (2438.4) 7-1/4" (184.2) 37-1/4" (946.2) 16-1/2" (419.1) 22-3/4" (577.9) 12-1/4" (311.2)9'0" (2743.2) 7-1/4" (184.2) 49-1/4" (1251) 16-1/2" (419.1) 22-3/4" (577.9) 12-1/4" (311.2)10”0" (3048) 7-1/4" (184.2) 61-1/4" (1555.8) 16-1/2" (419.1) 22-3/4" (577.9) 12-1/4" (311.2)
CL
CL
CL
CLCL
CL
A
B
E
35" (889) STANDARD
HINGE BACKSET: 5/16" (7.9)
DUTCH DOOR4-1/2" (114.3) OR 5" (127)
STRIKE BACKSET 5/16" (7.9)
4-7/8" (123.8)STRIKE
LLLL
D
C
50" (1270) STANDARD
SHELF HEIGHT IS42" (1066.8) STANDARD
NOTE:MAXIMUM FIRE LABELWIDTH: 3'8" (1117.6)
LLL
HINGE SIZE MAY VARY, LOCATION REMAINS THE SAME.CL
PLEASE INDICATE WHENADA COMPLIANCE ISREQUIRED. 48" CL IS NOTPRACTICAL WITH SOMEDEADLOCKS.
* *
49Frame Standard Rabbet Dimensions
FRAME TECHNICAL DATAApril 1, 2002ASSA ABLOY, the global leader
in door opening solutions
L
DOUBLE RABBET
SINGLE RABBET
MULLION
2" (50.8)
5/8" (15.8)
VARIES
1/2" (12.7)
DOORTHICKNESS DIMENSIONS
1-3/8" 1-15/16" (49.2)1-3/4" 1-9/16" (39.7)
2"* 1-9/16" (39.7)2-1/4"* 1-9/16" (39.7)
DOORTHICKNESS DIMENSIONS
1-3/8" 1-9/16" (39.7)1-3/4" 1-15/16" (49.2)
2"* 2-3/16" (55.5)2-1/4"* 2-7/16"
2" (50.8)
5/8" (15.8)
VARIES
1/2" (12.7)
DOORTHICKNESS DIMENSIONS
1-3/8" 1-9/16" (39.7)1-3/4" 1-15/16" (49.2)
2"* 2-3/16" (55.5)2-1/4"* 2-7/16"
2" (50.8)
5/8" (15.8)
VARIES
DOORTHICKNESS DIMENSIONS
1-3/8" 1-15/16" (49.2)1-3/4" 1-9/16" (39.7)
2"* 1-9/16" (39.7)2-1/4"* 1-9/16" (39.7)
DOORTHICKNESS DIMENSIONS
1-3/8" 1-9/16" (39.7)1-3/4" 1-15/16" (49.2)
2"* 2-3/16" (55.5)2-1/4"* 2-7/16"
* NOT AVAILABLEKNOCKDOWN (KD)
504-1/2" Ultima Hinge ReinforcementFRAME TECHNICAL DATANovember 15, 2004 ASSA ABLOY, the global leader
in door opening solutions
L
TO REMOVE SHIM PLATE, INSERT FLAT SCREWDRIVER BETWEEN SHIMAND REINFORCEMENT, AND PRY SHIM AWAY FROM REINFORCEMENT.
NOTE: IF SHIM IS REMOVED, PRIME PAINT HINGE REINFORCEMENT.
DRILLED AND TAPPED PER HINGE TEMPLATE
PROJECTIONS FOR RESISTANCE WELDING
5-9/16" (141.3)
9" (228.6)
1-19/64" (32.9)
18 GA. (1.2) STEEL SHIM PLATE
7 GA. (4.5) STEEL
MUDCAP STANDARD ON “M” SERIES FRAME
OFFSET IN 16 GA. (1.4) FRAMEWITH SHIM PLATE .134" (3.4)WITHOUT SHIM PLATE .180 (4.6)
.134" (3.4) .180" (4.6)
515" Hinge Reinforcement
FRAME TECHNICAL DATANovember 15, 2004ASSA ABLOY, the global leader
in door opening solutions
L
Heavy 5" Hinge Reinforcement
L
DRILLED AND TAPPED PERHINGE TEMPLATESTD. 12-24
PROJECTIONS FORRESISTANCE WELDING
5-9/16" (141.3)
9" (228.6)
7 GA. (4.5) STEEL
PROJECTIONS FORRESISTANCE WELDING
INDICATES HEAVY WEIGHT HINGE REINFORCEMENT
DRILLED AND TAPPED PERHINGE TEMPLATESTD. 12-24
NOTE: ELECTRICAL HINGE PREPARATIONAVAILABLE PER TEMPLATE
5-9/16" (141.3)
9" (228.6)
7 GA. (4.5) STEEL
1-5/8"(41.3)
1-5/8"(41.3)
52EH - Electric HingesFRAME TECHNICAL DATAJuly 1,2003 ASSA ABLOY, the global leader
in door opening solutions
SIZE AND LOCATIONPER TEMPLATE
PER TEMPLATE
PER TEMPLATE
53HFG Hinge Strap Reinforcement
FRAME TECHNICAL DATAApril 1, 2002ASSA ABLOY, the global leader
in door opening solutions
L
ARC WELD AS SHOWN
7 GA. (4.5) X 1-29/32" (40.4) X 10" (254)HINGE REINFORCEMENT.DRILLED AND TAPPED FOR 12-24 UNC (STANDARD)(1/4-20 UNC OPTIONAL)
HOLE FOR ABUSE-RESISTANT STUD(OPTIONAL)
HIGH FREQUENCY HINGE REINFORCEMENT STRAPS12 GA. (2.6) REINFORCEMENT
COVERBOX
54Full Width Hinge ReinforcementFRAME TECHNICAL DATANovember, 2004 ASSA ABLOY, the global leader
in door opening solutions
L
ARC WELD FULL WIDTH ALONG EACH END IN RABBETS (ONLY WHEN SPECIFIED).STANDARD WELDS INDICATED WITH AT END.
7 GA. (4.5) X JAMB DEPTH MINUS 1/2" (12.7) X 10"(254) HINGE REINFORCEMENT.DRILLED AND TAPPED FOR 12-24 UNC (STANDARD)(1/4-20 UNC OPTIONAL)
HOLE FOR ABUSE-RESISTANT STUD(OPTIONAL)
COVERBOX
55Continuous Hinge Reinforcement
FRAME TECHNICAL DATASeptember 1, 2005ASSA ABLOY, the global leader
in door opening solutions
L
3/4" (19.1)
12 GA. (2.6)REINFORCING
1/4" (6.4)
1/4" (6.4)
3/4" (19.1)
12 GA. (2.6)REINFORCING
SURFACE MOUNTED TYPE CONCEALED MOUNTED TYPE
HGCF CODE
NOTE: HINGE MANUFACTURERS RECOMMEND REINFORCEMENTS ON 20, 18, 16 GAUGE FRAMES.
HGCR CODE
56Security Hinge and Grout GuardFRAME TECHNICAL DATANovember, 2004 ASSA ABLOY, the global leader
in door opening solutions
L
ARC WELD FULL WIDTH ALONG EACH END
PROJECTIONS FOR RESISTANCE WELDING
7 GA. (4.5) X 1-19/32" (40.4) X 9" (228.6)HINGE REINFORCEMENT.DRILLED AND TAPPED FOR 12-24 UNC (STANDARD)(1/4-20 UNC OPTIONAL)OFFSET PER HINGE THICKNESS
HOLE FOR ABUSE-RESISTANT STUDPER TEMPLATE AS REQUIRED.
16 GA. (1.4) COVERBOX SPOT WELDED OVER HINGE REINFORCING.
57Electric Hinge and Grout Guard
FRAME TECHNICAL DATANovember, 2004ASSA ABLOY, the global leader
in door opening solutions
LARC WELD FULL WIDTH ALONG EACH END(OPTIONAL)
WELD PROJECTIONS FOR RESISTANCE WELDING
7 GA. (4.5) X 1-19/32" (40.4) X 9" (228.6)HINGE REINFORCEMENT.DRILLED AND TAPPED FOR 12-24 UNC (STANDARD)(1/4-20 UNC OPTIONAL)OFFSET PER HINGE THICKNESS
ELECTRICAL CONDUIT KNOCKOUT
16 GA. (1.4) GROUT GUARDCOVERBOX SPOT WELDEDOVER HINGE REINFORCING.
#8 PAN HEAD SCREWELECTRICAL HINGE WIREACCESS HOLE PER TEMPLATE.
NOTE: JUNCTION BOXES ARE NOT CAULKED AT THEFACTORY. TO BE FIELD CAULKED BY INSTALLATIONCONTRACTOR.
58HGA - Anchor Hinge Preparation FRAME TECHNICAL DATAApril 1, 2002 ASSA ABLOY, the global leader
in door opening solutions
L
7 GA. (4.5) HINGE REINF.
CURRIES DOES NOT DRILL AND TAPFOR HINGE SCREWS, UNLESS FRAME ISFACTORY WELDED AND PHYSICALSAMPLES ARE PROVIDED.
IF FRAME IS STICK OR KD THE PARTS ARESHIPPED LOOSE AND ARE NOT WELDEDTOGETHER, DRILL AND TAP IN FIELD.
ARC WELD
DOOR RABBET IS 1-15/16" (49.2)
59HGD - Hinge - Double ActingFRAME TECHNICAL DATA
April 1, 2002ASSA ABLOY, the global leaderin door opening solutions
L12 GA. (2.6)REINFORCING
.25 (6.4)
VERTICAL JAMB LINE
2.25 (57.2)
3.375(85.7)
NOMINALDOOR HEIGHT
60Pocket Pivot PreparationFRAME TECHNICAL DATAApril 1, 2002 ASSA ABLOY, the global leader
in door opening solutions
L
5/8" (15.9) STOP HEIGHTIF USING COVERBOX
7 GA. (4.5) REINF. TAB
PREPARATION:SIZE, DRILL AND TAP PER TEMPLATE
16 GA. (1.4) COVERBOX
PER TEMPLATE
PER TEMPLATE
NOTE: SOME POCKET PIVOTS REQUIRE FRAME FACE DIMENSIONS GREATER THAN 2" (50.8) - KD FRAMES NOT AVAILABLE OVER 2" FACE.
61SDL - Strike - Double Lip
FRAME TECHNICAL DATANovember, 2004ASSA ABLOY, the global leader
in door opening solutions
L
PER TEMPLATE
PER TEMPLATE
12 GA. (2.6)REINFORCING TABS
NOTE: CONTACT FACTORY ONAVAILABILITY WHEN USEDWITH “C” TYPE COMPRESSIONANCHOR KD FRAMES.
62Rescue Hardware FrameFRAME TECHNICAL DATANovember, 2004 ASSA ABLOY, the global leader
in door opening solutions
L
12 GA. (2.6) REINFORCEMENT
PER TEMPLATE
PER TEMPLATE
PREPARATION:SIZE, DRILL AND TAP PER TEMPLATE
DOUBLE LIP LATCH STRIKE12 GA. (2.6) REINFORCEMENT
COVERBOX
2" (50.8) MINIMUM FACE REQUIRED FOR COVERBOX
7-3/4"(196.9)
PERTEMPLATE
FLOORLINE
CL
CL
EMERGENCY STOP STRIKE SIDE
NOTE: CONTACT FACTORY ON AVAILABILITY WHEN USEDWITH “C” TYPE COMPRESSION ANCHOR KD FRAMES.
63Frame Pivots - Top, Bottom - Center Hung
FRAME TECHNICAL DATADecember, 2006ASSA ABLOY, the global leader
in door opening solutions
TOP PIVOT7 GA. (4.5) REINF.
COVERBOX
MUDCAP
MUDCAP
CENTER HUNGCASED OPENING
TOP AND BOTTOM DOUBLE ACTING PIVOT
PREPARATION:SIZE, DRILL AND TAP PER TEMPLATE
BOTTOM PIVOT7 GA. (4.5) REINF.
TOP PIVOT7 GA. (4.5) REINF.1/8" INSET OR EDGE HUNG
COVERBOX
EDGE HUNGCASED OPENING
TOP AND BOTTOM SINGLE ACTING PIVOT
PREPARATION:SIZE, DRILL AND TAP PER TEMPLATE
BOTTOM PIVOT7 GA. (4.5) REINF.
EDGE HUNGNOTE: NOT ALL BOTTOM PIVOTS REQUIRE A FRAME PREP.
64Frame Pivots - Top, Intermediate, Bottom - Single ActingFRAME TECHNICAL DATAApril 1, 2002 ASSA ABLOY, the global leader
in door opening solutions
L
BOTTOM PIVOT7 GA. (4.5) REINF.
INTERMEDIATE PIVOT7 GA. (4.5) REINF.
TOP PIVOT7 GA. (4.5) REINF.
COVERBOX
MUDCAP
65E1 Strike Reinf. (ANSI A115) 1-1/4" x 4-7/8"
FRAME TECHNICAL DATAApril 1, 2002ASSA ABLOY, the global leader
in door opening solutions
L
E2 Strike Reinf. (ANSI A115) 1-1/8" x 2-3/4"
L
16 GA. (1.4) REINF.COVER BOX1-1/16" (27) DEEP
1-1/4" (31.8)
4-7/8"(123.8)
40" (1016) TO STANDARD ON 1-3/4" (44.5) DOOR
CL
STANDARD STRIKEBACKSET 5/16" (7.9)
SCREW HOLES ARE EXTRUDEDTO PROVIDE THREAD DEPTH
EQUAL TO 12 GA. (2.6) PLATE
16 GA. (1.4) REINF.COVER BOX1" (25.4) DEEP
1-1/8" (28.6)
2-3/4"(69.9)
40" (1016) TO STANDARD ON 1-3/4" (44.5) DOOR
40-5/16" TO STANDARD ON 1-3/8" DOOR
CL
STANDARD STRIKEBACKSET 3/8" (9.5)
1-3/4" DOORBACKSET 3/16"
1-3/8" DOOR
SCREW HOLES ARE EXTRUDEDTO PROVIDE THREAD DEPTH
EQUAL TO 12 GA. (2.6) PLATE
SIZE AND TAP PER ANSI 115.2
SIZE AND TAP PER ANSI 115.1 AND 115.2
CL
66E1B - Strike Reinf. - 1-1/4" x 4-7/8" - No LipFRAME TECHNICAL DATAApril 1, 2002 ASSA ABLOY, the global leader
in door opening solutions
L
4-7/8"(123.8)
1-1/4"(31.8)
40" (1016) TOSTANDARD ON 1-3/4" (44.5) DOOR
CL
12 GA. (2.6)REINF. TABS
PER TEMPLATE
67E3 Deadlock Strike Reinf. (ANSI/A115) 1-1/8" X 3-1/2"
FRAME TECHNICAL DATAApril 1, 2002ASSA ABLOY, the global leader
in door opening solutions
L
E4 Deadlock Strike Reinf. (ANSI/A115) 1-1/8" x 2-3/4" No Lip
L
16 GA. (1.4) REINF. COVER BOX1-1/16" (27) DEEP
1-1/8" (28.6)
3-1/2"(88.9)
48" (1219) TO STANDARD ON 1-3/4" (44.5) DOOR
CL
STRIKE BACKSET 3/8" (9.5)
12 GA. (2.6) REINF. TAB
SIZE AND TAP PER ANSI 115.5
16 GA. (1.4) REINF. COVER BOX1" (25.4) DEEP
1-1/8" (28.6)
2-3/4"(69.9)
48" (1219) TO STANDARD ON 1-3/4" (44.5) DOOR
CL
STRIKE BACKSET 3/8" (9.5)
SCREW HOLES ARE EXTRUDEDTO PROVIDE THREAD DEPTH
EQUAL TO 12 GA. (2.6) PLATE
SIZE AND TAP PER ANSI 115.4
68EJ2 - Jamb Lock - 2" (50.8) FaceFRAME TECHNICAL DATAApril 1, 2002 ASSA ABLOY, the global leader
in door opening solutions
L
PERTEMPLATE
PERTEMPLATE
PERTEMPLATE
REINF. TABSPER TEMPLATE
PERTEMPLATE
2" (50.8) MIN. FACE3-1/16" (77.8) MIN. FACEON DRYWALL FRAME
40" (1016)
CL
69EJ4, EJ8, EJ12 - Jamb Lock
FRAME TECHNICAL DATAApril 1, 2002ASSA ABLOY, the global leader
in door opening solutions
L
PERTEMPLATE
COVERPLATE
PERTEMPLATE
CUTOUTSPER
TEMPLATE
4" (101.6) STANDARD8" (203.2) STANDARD12" (304.8) STANDARD
STRIKE40" (1016)
CL
70E30 - Strike - Pocket LockFRAME TECHNICAL DATAJuly 1,2003 ASSA ABLOY, the global leader
in door opening solutions
L
PER TEMPLATE
PER TEMPLATE
7 GA. (4.5)REINF. TABS
40" (1016)
CL
71MAG - Magnetic Lock
FRAME TECHNICAL DATAJuly 1, 2003ASSA ABLOY, the global leader
in door opening solutions
L
PER TEMPLATE
PER TEMPLATE
REINF. TABSPER TEMPLATE
72E5 Rim Vertical Rod Surface Strike Reinf.FRAME TECHNICAL DATAApril 1, 2002 ASSA ABLOY, the global leader
in door opening solutions
L
G20 Vertical Rod Exit Mortise Strike Preparation
L
1-3/4" (44.5)
12 GA. (2.6)
10" (254)
CL
12 GA. (2.6) REINF. WELDEDTO INSIDE OF SOFFIT TIGHTTO DOOR RABBET STOP
G20 PREPARED FOR MORTISE STRIKES PERTEMPLATE OF HARDWARE MANUFACTURER
SPECIFY EXIT DEVICE AND STRIKE BEING USED WHEN ORDERING
E5 REINFORCING IS LOCATED ON CENTERLINE OF HEAD FOR PAIR FRAMESAND ADJACENT TO STRIKE JAMB ON SINGLE SWING FRAMES.
DOOR RABBET
HEADS
DOOR
73E8 Rim Exit Reinforcement
FRAME TECHNICAL DATAApril 1, 2002ASSA ABLOY, the global leader
in door opening solutions
L
12 GA. (2.6)REINF. WELDEDTO INSIDE OFSOFFIT TIGHT TODOOR RABBETSTOP
41" (1041.4) TO STANDARD
CL
8" (203.2)
1-1/4" (31.8)*
12 GA. (2.6)
DOOR
* THE REINFORCEMENT WIDTH WILL BE EQUAL TO THE SOFFIT WIDTH WHEN LESSTHAN 1-1/4" (31.8). CUSTOMER SHOULD VERIFY HARDWARE COMPATIBILITYBEFORE ORDERING NARROW SOFFITS.
74E9 Electric StrikesFRAME TECHNICAL DATAApril 1, 2002 ASSA ABLOY, the global leader
in door opening solutions
L
NOTE: FIRE RATED FRAMES INCORPORATING AN ELECTRIC STRIKE WITH A COVERBOX, REQUIRE THAT THE WALL BOARD PENETRATE THE THROAT OF THE FRAME BY 1/2" (12.7) MINIMUM. ELECTRIC STRIKE MUST BE LISTED FOR USE WITH FIRE RATED OPENINGS.
16 GA. (1.4) REMOVABLECOVER BOX
CONFIGURATION OF CUTOUT VARIESPER HARDWARE MFG. TEMPLATE
SPECIFY STRIKE BEING USED WHEN ORDERING
STRIKECL
VERTICAL LOCATION OF ELECTRICSTRIKE WILL VARY WITH THE HARD-WARE MANUFACTURER, WHENORDERING FRAMES PREPARED FORAN ELECTRIC STRIKE, SPECIFY THETYPE OF LOCK BEING USED ALONGWITH CENTERLINE DIMENSIONREQUIRED OF THE LOCK.
7/8" (22.2) DIA.KNOCKOUT FOR ELECTRIC CONNECTOR
12 GA. (2.6) REINF. TAB
75Conduit - Coverbox Clearance Dimensions
FRAME TECHNICAL DATASeptember1, 2005ASSA ABLOY, the global leader
in door opening solutions
L1-1/8" (28.6) OR 7/8" (22.2) DIA.KNOCKOUT
RABBET CL
FACE
END VIEW OF FRAME AND COVERBOX
REMOVABLE COVER
AS REQUIRED
CL
CL
DEPTH
WIDTH
COVERBOX
1/2" (12.7) CONDUIT CONNECTOR LOCKNUTBY OTHERS1/2" (12.7) CONDUIT CONNECTOR
BY OTHERS
SIDE VIEW OF COVERBOX
LOCKNUT
1-1/8" (28.6)*
MINIMUM INSIDE DEPTH DIMENSION REQUIREDTO ACCOMODATE THE LOCKNUT.
* 1-1/2" (38.1) FOR 3/4" CONDUIT CONNECTOR
1/2" CONDUIT CONNECTORS ARE FOR 7/8” KNOCKOUT / 1-1/8” HIGH COVERBOX3/4" CONDUIT CONNECTORS ARE FOR 1-1/8" KNOCKOUT / 1-1/2" HIGH COVERBOX
DOUBLE KNOCKOUT FOR 1/2" AND 3/4"
CONDUIT CONNECTORS ARE FOR THE 1-1/2" HIGH COVER BOX ONLY
1-1/8" HIGH COVERBOX HAS 7/8" KNOCKOUTONLY FOR 1/2" CONDUIT CONNECTOR
1/2"(12.7)
3/4"(19.1)
76Conduit Preparation (RW-3)FRAME TECHNICAL DATAApril 1, 2002 ASSA ABLOY, the global leader
in door opening solutions
L
6.00" + 1.00"
TOP
JAMB MULLION
HEAD MULLION
LOCK SIDE
6.00" + 1.00"
1/2" STEEL FLEXIBLE CONDUITFACTORY INSTALLED WHEN REQUESTED(MULLION ONLY)
77E10 Standard Mtg. 14 ga. Closer Reinf.
FRAME TECHNICAL DATAJanuary 1, 2005ASSA ABLOY, the global leader
in door opening solutions
L
E11 Parallel Arm Mtg. 14 ga. Closer Reinf.
L
14 GA. (1.9)
1-3/4" (44.5)10" (254)
7" (177.8)
14 GA. (1.9)
1-1/4" (31.8)
20" (508)
14 GA. (1.9) REINF. WELDEDTO INSIDE OF SOFFIT TIGHTTO DOOR RABBET STOP
DOOR
HINGE SIDE
HINGE SIDEDOOR
NOTE: WHEN SOFFIT WIDTH IS LESS THAN 1" - E16 WILL BE USED
78E12 Top Jamb Mtg. 14 ga. Closer Reinf.FRAME TECHNICAL DATANovember 15, 2004 ASSA ABLOY, the global leader
in door opening solutions
L
14 GA. (1.9)
2" (50.8)
16" (406.4)
1-3/4" (44.5)2-3/4" (69.9)
DOOR
HINGE SIDE
79E13 Corner Bkt. Mtg. 14 ga. Closer Reinf.
FRAME TECHNICAL DATAJanuary 1, 2005ASSA ABLOY, the global leader
in door opening solutions
L
Double Egress Frame Closer Reinforcements
L
14 GA. (1.9)
1-1/4" (31.8)
8" (203.2)
8" (203.2)
14 GA. (1.9) REINF. WELDEDTO INSIDE OF SOFFIT TIGHTTO DOOR RABBET STOP
E11 ------------------PARALLEL ARM MOUNTING------------------14 GA. (1.9)20" (508) LONG
E10 ------------------REGULAR MOUNTING --------------------------14 GA. (1.9)10" (254) LONG
E12 ------------------TOP JAMB MOUNTING ------------------------14 GA. (1.9)16" (406.4) LONG
E17A ----------------FULL SLEEVE --------------------------------------14 GA. (1.9)REGULAR, TOP JAMB 16" (406.4) LONGPARALLEL ARM MOUNTINGS
E18 ------------------HALF SLEEVE --------------------------------------14 GA. (1.9)REGULAR AND 16" (406.4) LONGPARALLEL ARM MOUNTINGS
REGULARTOP
JAMB
DOOR
HINGE SIDE
80E15 Electric-Door Holder -Release/Closer 14 ga. Reinf.FRAME TECHNICAL DATANovember 15 , 2004 ASSA ABLOY, the global leader
in door opening solutions
L
E16 Double Parallel Arm 14 ga. Closer Reinf.
L
14 GA. (1.9)
*PER TEMPLATE
*PER TEMPLATE
14 GA. (1.9)
VARIES PER SOFFIT WIDTHUP TO 1-5/8" (41.3)
1-1/4" (31.8)
14 GA. (1.9) ADDITIONAL REINF. ADDEDWHEN SOFFIT IS UNDER 2" (50.8) IN WIDTH
20" (508)
20" (508)
14 GA. (1.9) ADDITIONAL REINF. WELDEDTO INSIDE OF SOFFIT TIGHT TO DOORRABBET STOP
DOOR
DOOR
* SPECIFY MANUFACTURER AND MODEL NUMBER WHEN ORDERINGADVISE POWER SOURCE LOCATION IF REQUIRED
HINGE SIDE
HINGE SIDE
81E17 14 Ga. Full Sleeve Closer Reinforcement
FRAME TECHNICAL DATANovember 15 ,2004ASSA ABLOY, the global leader
in door opening solutions
L
E18 14 ga. Formed Half Sleeve Closer Reinf.
L
14 GA. (1.9)
1-3/4" (44.5)
16" (406.4)
1" (25.4) MIN.
1-3/4" (44.5)
14 GA. (1.9)
2-3/8" (60.3)
1" (25.4) MIN.
1-3/4" (44.5)
HINGEJAMBLINE
16" (406.4)
NOTE: FULL SLEEVE CLOSER REINF. ARE BUILT TO MATCH FRAME PROFILES
16" (406.4)14 GA. (1.9)
1-3/4" (44.5)
1-3/8" (34.9) NOTE 13/4" (19.1) NOTE 2
5/8" (15.9)
1-15/16" (49.2) FOR 1-3/4" (44.5) DOOROR
1-9/16" (39.7) FOR 1-3/8" (34.9) DOOR
NOTE:1) 1-1/2" (38.1) MINIMUM SOFFIT REQ’D2) 1" (25.4) MINIMUM SOFFIT REQ’D
NOTE: HALF SLEEVE CLOSER REINF. ARE BUILT TO MATCH FRAME PROFILES
DOORHINGE SIDE
82EPT - Electronic Power TransferFRAME TECHNICAL DATAApril 1, 2002 ASSA ABLOY, the global leader
in door opening solutions
L
TOP HINGE
PER TEMPLATE
6" (152.4)*STANDARD
12 GA. (2.6)REINFORCINGTABS
PERTEMPLATE
PER TEMPLATE
* WOOD DOORS MAY REQUIRE OTHER LOCATION - CONTACT DOOR MANUFACTURER
83G21 - G22 Removable Hardware Mullion
FRAME TECHNICAL DATAApril 1, 2002ASSA ABLOY, the global leader
in door opening solutions
L
H3A - H3B Surface Bolt Preparation
L
MULLION TOP BRACKET MOUNTING SCREWS TO BE DRILLED ANDTAPPED IN FIELD BY HARDWARE INSTALLER.
G21 PLATE REINFORCEMENTUSED WHEN SOFFIT IS 3" (76.2)WIDE OR GREATER.
G21
G22 PLATE REINFORCEMENTUSED WHEN SOFFIT IS LESS THAN3" (76.2).
G22
5/8" (15.9) C.R.S. FILLER BLOCK ISFURNISHED WHEN SOFFIT WIDTH IS TOONARROW TO APPLY HARDWARE TO SOFFIT
PLUG WELDED ONLY
WELDEDDOORDOOR HARDWARE MULLIONASSEMBLY
H3B-12 GA. (2.6)
H3A-12 GA. (2.6)
1-3/4" (44.5)
1-3/4" (44.5)
10" (254)
10" (254)
H3A FACE PREP.12 GA. (2.6) REINF. WELDEDTO INSIDE OF FRAME FACE
CLHEAD AND REINFORCEMENT
H3B SOFFIT PREP.12 GA. (2.6) REINF. WELDEDTO INSIDE OF SOFFIT TIGHT
TO DOOR RABBET STOP
NOTE: WHEN ORDERING SPECIFYEITHER H3A OR H3B REINFORCING
12 GA. (2.6)
DOOR
OF DOORS
DOOR SIDE
84G24 Coordinator ReinforcementFRAME TECHNICAL DATAApril 1, 2002 ASSA ABLOY, the global leader
in door opening solutions
L
12 GA. (2.6)
1-3/8" (34.9) 10" (254)
CL
12 GA. (2.6) REINF. WELDEDTO INSIDE OF FRAME FACE.
DOOR
OF DOORSCL
OF PAIR
2" (51)
85Grout Hole
FRAME TECHNICAL DATAApril 1, 2002ASSA ABLOY, the global leader
in door opening solutions
L
RABBET PREPARATION(OPPOSITE DOOR RABBET STANDARD)
FACE PREPARATION(DOOR FACE STANDARD)
12 GA. (2.6) REINF. PLATE1-3/8" (35) DIA.HOLE IN REINF. PLATE
12 GA. (2.6) REINF. PLATE1-3/8" (35) DIA.HOLE IN REINF. PLATE
FILLER PLATESAME GAUGE AS FRAME.SHIPPED LOOSE.1-3/8" X 1-3/8"(35 X 35)
FILLER PLATESAME GAUGE AS FRAME.SHIPPED LOOSE.1-3/8" X 1-3/8"(35 X 35)
86H1 Flush Bolt ReinforcementFRAME TECHNICAL DATAApril 1, 2002 ASSA ABLOY, the global leader
in door opening solutions
L
H2 Flush Bolt Prep. and Reinf. (ANSI)
L
1-1/4" (31.8)12 GA. (2.6)
8" (203.2)
OF OPENING AND REINFORCEMENTCL
12 GA. (2.6) REINF. WELDED IN CENTER OF DOOR RABBETCL
12 GA. (2.6) 16 GA. (1.4) REINF. COVER BOX1-1/16" (27) DEEP
2-1/4" (57.2)
CL
CL
OF DOORS
CUTOUT
INACTIVE DOOR
13/16" (20.6)
15/16" (23.8)
15/32" (11.9) BACKSET
SIZE AND TAP PER ANSI 115.4
DOOR
DOOR
87H4 Auto Flush Bolt
FRAME TECHNICAL DATAApril 1, 2002ASSA ABLOY, the global leader
in door opening solutions
L
H5 Non-handed Flush Bolt
L
PREPARATION FOR AUTOMATIC FLUSH BOLT IS PER HARDWARE MANUFACTURER’S TEMPLATE.
PLEASE SPECIFY MANUFACTURER AND MODEL NUMBER WHEN ORDERING.
LABELED IF HARDWARE IS APPROVED AND PREPPED TO TEMPLATE.
3-7/8" (98.4)
12 GA. (2.6) REINF.
15/16" (23.8)
OF DOORSCL
NOTE: STRIKE PLATE INSTALLEDFILLER PLATE MAY BE PURCHASEDSEPARATELY IN PACKAGES OF50 PIECES WITH SCREWS.
3-1/4" (82.6) 16 GA. (1.4) GALV. FILLER PLATEPART #CF004637
16 GA. (1.4) GALV. FILLER PLATEPART #CF001257
C' SUNK FOR #8-32 X 5/8" (15.9)FLAT HEAD HARDWARE SCREW
HEADCLCL
7/8" (22.2)
CL
5/8" (15.9)1-1/8" (28.6)
88Electric Magnetic Door Position SwitchFRAME TECHNICAL DATAApril 1, 2002 ASSA ABLOY, the global leader
in door opening solutions
L
16 GA. (1.4) GROUT GUARD COVERBOX ENDS SPOTWELDED OVER PREPARATION.
ELECTRICAL CONDUITKNOCKOUT AS REQUIRED.
#8 PAN HEAD SCREW.
CUTOUT SIZE AND LOCATIONPER HARDWARE TEMPLATE
12 GA. (2.6)REINFORCING TAB.
NOTE: JUNCTION BOXES ARE NOT CAULKED AT THE FACTORY. TO BE FIELDCAULKED BY INSTALLATION CONTRACTOR.
89Electric Fully-Concealed Door Position Switch
FRAME TECHNICAL DATAApril 1, 2002ASSA ABLOY, the global leader
in door opening solutions
L
16 GA. (1.4) GROUT GUARD COVERBOX SPOTWELDED OVER PREPARATION.
ELECTRICAL CONDUITKNOCKOUT AS REQUIRED.
#8 PAN HEAD SCREW.
CUTOUT SIZE AND LOCATIONPER HARDWARE TEMPLATE
12 GA. (2.6)REINFORCING TAB.
NOTE: JUNCTION BOXES ARE NOT CAULKED AT THE FACTORY. TO BE FIELDCAULKED BY INSTALLATION CONTRACTOR.
90Cabinet Jamb FrameFRAME TECHNICAL DATAApril 1, 2002
ASSA ABLOY, the global leaderin door opening solutions
L
DOOR OPENING
ROUGH OPENING
DOOR OPENING
ROUGH OPENING
NOT U.L. LISTEDS.M.W. JAMB SECTIONBUCKS SHIP LOOSE SQUARE BUTT ENDFIELD ASSEMBLED WITH SCREWSOR WELDED
1-3/4" (44.5)1" (25.4)
1-7/8" (47.6)
ROUGH OPENING DETERMINESTHE LENGTH OF THE BUCK LEGS
MACH SCREW#8 X 1/2" PAN HEAD
7/8" (22.2)
91Rough Buck Frame
FRAME TECHNICAL DATAApril 1, 2002ASSA ABLOY, the global leader
in door opening solutions
L
2-1/2" (63.5) MIN.3" (76.2) MAX.
2-1/2" (63.5) MIN. TYP.3" (76.2) MAX. TYP.
DOOROPENING
ROUGHOPENING
DOOR OPENING
ROUGH OPENING
U.L. LISTED ROUGH BUCK FRAMESBUCKS SHIPPED LOOSE SQUARE BUTT END.FULLY PREPARED FOR INSTALLATIONWITH MOUNTING HOLES.
FINISH BUCK16 GA. (1.4) OR 14 GA. (1.9)
HINGE OR STRIKE REINF.1/4-20 NC X 1-1/4"FLAT HEAD MACH SCREW
2" (50.8)
2" (50.8)
#8 x 1/2"PAN HEADMACH SCREW
12 GA. (2.6) REINF. SUB-CHANNELU.L. FRAME ONLY
SUB-BUCK14 GA. (1.9) ONLY FOR LABEL
2" (50.8)
2" (50.8)
CORNER DETAILCORNER IS NOTCHED FOR FIELD INSTALLATIONFINISH BUCK CAN NOT BE WELDED PRIOR TOINSTALLATION.
NOTE: LABEL FRAMES FURNISHED WITH ATTACHING SCREWS AND BOLTS FOR ASSEMBLY
92Curriseal Frame Flush KD - WM - WGFRAME TECHNICAL DATASeptember, 2003 ASSA ABLOY, the global leader
in door opening solutions
L
K.D. “M” TYPE FLUSHGAUGE - 18 GA. (1.2), 16 GA. (2.4), 14 GA. (1.9)JAMB DEPTHS:
DOUBLE RABBET (WM) 5-1/4" (133.4) - 14" (355.6) (1/8" (3.2) INCREMENTS)SINGLE RABBET (WG) 4-1/8" (104.8) - 14" (355.6) (1/8" (3.2) INCREMENTS)
AVAILABLE WITH 4" (101.6) FACE HEADSDOUBLE RABBET AVAILABLE IN COMMUNICATING FRAMESWITH A 6-1/2" (165.1) MIN. JAMB DEPTH
HARDWARE RESTRICTIONSNOT RECOMMENDED- CLOSERS WITH REMOVABLE STOPS- VERTICAL ROD DEVICES WITH STRIKES MORTISED IN THE STOP- STOP ACTIVATED VERTICAL ROD DEVICES
NOTE: SOFFIT MOUNTED SURFACE HARDWARE MAY REQUIRE+_ 1/8" (3.2) ADJUSTMENT OF MOUNTING HOLES TO ACCOMODATEWEATHERSTRIP AND ENSURE NORMAL DOOR OPERATION.
CURRISEALACTUAL SIZE
COLOR: DARK BROWN
2-1/8"(54.0)
1-9/16" (39.7)
1-15/16" (49.2)ORVARIES
5/8" (15.9)ONLY
1" (25.4)1-1/4" (31.8)1-1/2" (38.1)1-3/4" (44.5)
2" (50.8)
1/2" (12.7)*
2-5/8" (66.7)ONLYWG
WM/WG
1-3/4" DOOR(44.5)
1/4" (6.3)
1/8" (3.2)
5-3/4" (146.1) JAMB DEPTH AVAILABLE WITH 7/16" (11.1) RETURNSTO PROVIDE A 4-7/8" (123.8) THROAT OPENING
CURRISEAL FRAME IS DESIGNED FOR USE WITH THE CURRISEAL ONLY
*KD CORNER
93Curriseal Frame KD Drywall - WC - WCG
FRAME TECHNICAL DATASeptember, 2003ASSA ABLOY, the global leader
in door opening solutions
L
K.D. “C” TYPE DRYWALLGAUGE - 18 GA. (1.2), 16 GA. (2.4), 14 GA. (1.9)JAMB DEPTHS:
DOUBLE RABBET (WC) 5-1/4" (133.4) - 14" (355.6) (1/8" (3.2) INCREMENTS)SINGLE RABBET (WCG) 4-1/8" (104.8) - 14" (355.6) (1/8" (3.2) INCREMENTS)
DOUBLE RABBET AVAILABLE IN COMMUNICATING FRAMESWITH A 6-1/2" (165.1) MIN. JAMB DEPTH
HARDWARE RESTRICTIONSNOT RECOMMENDED- CLOSERS WITH REMOVABLE STOPS- VERTICAL ROD DEVICES WITH STRIKES MORTISED IN THE STOP- STOP ACTIVATED VERTICAL ROD DEVICES
NOTE: SOFFIT MOUNTED SURFACE HARDWARE MAY REQUIRE+_ 1/8" (3.2) ADJUSTMENT OF MOUNTING HOLES TO ACCOMODATEWEATHERSTRIP AND ENSURE NORMAL DOOR OPERATION.
CURRISEALACTUAL SIZE
COLOR: DARK BROWN
2-1/8"(54.0)
1-9/16" (39.7)
1-15/16" (49.2)ORVARIES
5/8" (15.9)ONLY
1-1/2" (38.1)1-3/4" (44.5)
2" (50.8)
1/2" (12.7)
2-5/8" (66.7)ONLYWC/WCG
1-3/4" DOOR(44.5)
1/4" (6.3)
1/8" (3.2)
CURRISEAL FRAME IS DESIGNED FOR USE WITH THE CURRISEAL ONLY
KD CORNER
3/8" (9.5)
96Communicating FrameFRAME TECHNICAL DATAApril 1, 2002 ASSA ABLOY, the global leader
in door opening solutions
L
NOTE:U.L. AND W.H.I. LABELED FRAMES MAY BE PROVIDEDWITH COMPRESSION TYPE ANCHORING SYSTEM.
“M” PROFILE FLUSH K.D. “C” & “CM” PROFILE DRYWALL
EQUAL RABBET1-15/16" (49.2) FOR 1-3/4" (44.5) DOORS4-7/8" (117.5) THRU 14" (355.6) JAMB DEPTH
UNEQUAL RABBET1-15/16" (49.2) X 1-9/16" (39.7) FOR1-3/4" (44.5) X 1-3/8" (34.9) DOORS4-1/2" (114.3) THRU 14" (355.6) JAMB DEPTH
EQUAL RABBET1-9/16" (39.7) FOR 1-3/8" (34.9) DOORS4-7/8" (117.5) THRU 14" (355.6) JAMB DEPTH
EQUAL RABBET1-9/16" (39.7) FOR 1-3/8" (34.9) DOORS4-7/8" (117.5) THRU 14" (355.6) JAMB DEPTH
UNEQUAL RABBET1-15/16" (49.2) X 1-9/16" (39.7) FOR1-3/4" (44.5) X 1-3/8" (34.9) DOORS4-1/2" (114.3) THRU 14" (355.6) JAMB DEPTH
EQUAL RABBET1-15/16" (49.2) FOR 1-3/4" (44.5) DOORS4-7/8" (117.5) THRU 14" (355.6) JAMB DEPTH
97Pocket Door Frame - Standard 1-3/8" or 1-3/4" Door Single
FRAME TECHNICAL DATAJune, 2006 ASSA ABLOY, the global leader
in door opening solutions
L
2"(50.8)
2" (50.8)FINISH OPENING
**
1
32
NOMINALDOOR
OPENING HEIGHT
*
2" (50.8)
NOMINALDOOR
OPENING HEIGHT
*
5/8" (15.9)
5/8" (15.9)
DOOR
1
VERIFY HARDWARE ADAPTABILITYFRAME MUST BE INSTALLED AND
HARDWARE TRACK MUST BE HUNGPRIOR TO FINISH WALL STUDS BEING SET.
AVAILABLE IN 18 GA. (1.2) AND 16 GA.(1.4) STEEL.
2" (50.8)
2" (50.8)FINISH OPENING WIDTH
**1/2" (12.7)
1/2" (12.7)
2
5/8" (15.9)
2" POCKET(50.8)
1-3/4" (44.5) DOOR 3
NOTE: 1-3/8" (34.9) DOORFRAME HAS 1-5/8" (41.3) POCKET
EQUAL
EQUAL
1" (25.4)DOOR
1/2" (12.7)
1/2" (12.7)
4" (101.6) MIN.12" (304.8) MAX.
ANCHORSUSED FOR METAL STUDOR WOOD STUD WALL
1" (25.4)
4-1/4" (107.9)
VARIES WITH JAMB DEPTH & STUD SIZE.SPECIFY STUD SIZE WHEN ORDERING.
FINISH OPENING WIDTH IS 1" (25.4) LESSTHAN A STANDARD OPENING WIDTH.EXAMPLE: A 3'0" (914.4) POCKET FRAME WILLHAVE FINISH OPENING WIDTH OF 2'11" (889).THIS ALLOWS THE USE OF STANDARD DOOR WIDTHS.
FINISH OPENING HEIGHT IS NOMINAL DOOR HEIGHTUSING CURRIES STANDARD DOOR UNDERCUT.
**
*
TRACK HARDWARE &REINFORCEMENT
PROVIDED BY OTHERS
98Pocket Door Frame-Saw Mitered-Welded for 1-3/4" or 1-3/8" DoorsFRAME TECHNICAL DATAJune, 2006 ASSA ABLOY, the global leader
in door opening solutions
L
1. MITER HEAD AND JAMB AT 45˚2. CLAMP AND TACK WELD AT BACKBEND AND FACE.3. CONTINUOUS WELD INSIDE SEAM.4. GRIND AND FINISH OUTSIDE SURFACES.
SPLIT HEAD AND HINGE JAMB
A
B
C
A
B
C
STRIKE JAMB
FLOOR ANCHOR
99Stainless Steel Slip-On Type Spats
FRAME TECHNICAL DATAApril 1, 2002ASSA ABLOY, the global leader
in door opening solutions
L
STAINLESS STEEL SLIP-ON SPATSTANDARD PROFILE IS MANUFACTUREDTO FIT OVER JAMB PROFILE.SPECIFY JAMB PROFILE WHEN ORDERING
20 GA. (.91) #304 STAINLESS STEEL#4 SATIN GRAIN FINISH
NOTE:SPATS ARE LABELED UP TOA HEIGHT OF 8" (203.2)
4" (101.6)STANDARD
4" (101.6)STANDARD
HOSPITAL TYPE SPATSTANDARD PROFILE IS MANUFACTURED
TO FIT OVER JAMB BELOW STOP.SPECIFY JAMB PROFILE WHEN ORDERING
20 GA. (.91) #304 STAINLESS STEEL#4 SATIN GRAIN FINISH
NOTE:HOSPITAL TYPE SPATS
ARE LABELED UP TOA HEIGHT OF 6" (152.4)
100Hospital StopFRAME TECHNICAL DATAApril 1, 2002 ASSA ABLOY, the global leader
in door opening solutions
L
ANCHOR PART NUMBER: P0079FILLER & BACKING PLATEUSED ON FRAMES NOT REQUIRING A FOOT CLIP ORFRAMES THAT HAVE SOME OTHER BASE ANCHORING METHOD.
ANCHOR PART NUMBER: P0077FILLER & COMBINATION BACKING PLATE-FOOT CLIPUSED ON FRAMES REQUIRING A FOOT CLIP.
NOTE: FOOTCLIP REQUIREDFOR LABEL
VARIES
STOP CUT AWAY ON 45˚ ANGLE TO RECEIVE FILLER
4" (101.6)STANDARD
FILLER SIZES AVAILABLEUP TO 9" (228.6) HIGH
CHOOSE EITHER P0077 OR P0079BACKING PLATE.WELD BACKING PLATE BEHINDCUTOUT.WELD FILLER INTO CUTOUT, GRIND,FILL AND FINISH SMOOTH.
4" (101.6) STANDARDFROM FACTORY
*
HEIGHTS AVAILABLE UP TO 9" (228.6) HIGH6" (152.4) HIGH MAXIMUM ON FIRE RATED FRAMESFACTORY INSTALLED OR BY SECOND LOCATION SHOP
*
45˚ CUT
101Thermal Break Frame KD Flush Profile
FRAME TECHNICAL DATAApril 1, 2002ASSA ABLOY, the global leader
in door opening solutions
L
14 GA. (1.9) AND 16 GA. (1.4) GALVANEALED STEEL
#8 X 1/2" (12.7) PAN HEAD S.M.S.
2" (50.8) OR 4" (101.6) FACE HEAD
DOOR RABBET
5-1/2" (139.7)THRU 10-3/4" (273.1)
JAMB DEPTH
2" (50.8) FACE
STEEL POP RIVETS IN PAIRSON 12" (305) CENTERS MAXIMUM
CLOSED CELL POLYETHYLENE FOAM
DOOR RABBET
THERMAL BREAK FRAME PROVIDES A 57% REDUCTION IN THERMAL CONDUCTIVITY.PUNCH FOR SILENCERS NOT AVAILABLE.
102Thermal Break Frame CCW Stick ComponentsFRAME TECHNICAL DATAApril 1, 2002 ASSA ABLOY, the global leader
in door opening solutions
L
16 GA. (1.4) AND 14 GA. (1.9) GALVANEALED STEEL ONLY5/8" (15.9) HIGH STOPS ONLY BUTT END JOINTS ONLYNOT LABELED
5-1/2" (139.7)THRU 10-3/4" (273.1)
JAMB DEPTH
2" (50.8) OR 4" (101.6) FACE
DO
OR
RA
BB
ET
DO
OR
RA
BB
ET CLOSED CELL POLYETHYLENE FOAM
STEEL POP RIVETS ON 12" (305) CENTERS MAXIMUM
MULLION - 16 GA. (1.4) AND 14 GA. (1.9) 2" (50.8) FACE ONLY.PUNCH FOR SILENCERS NOT AVAILABLE.
2" MAX.(50.8)
103CCW - Drip Cap CCW 112 - 10'6-5/8" Lengths
FRAME TECHNICAL DATAApril 1, 2002ASSA ABLOY, the global leader
in door opening solutions
L
Mullion Construction
L
10'6-5/8" (3216.3)
1" (25.4)
3/4" (19)
45˚DRIP CAP
C.C.W. 112
16 GA. (1.4) GALVANEAL
104Removable Vertical Mullion / BracketFRAME TECHNICAL DATAAugust 20, 2003 ASSA ABLOY, the global leader
in door opening solutions
L
MULLION BRACKET IS USED AT THE TOP AND BOTTOM OF FRAME
ATTACH MULLION BRACKET TO FRAME
NOTCH MULLION FACE TO ALLOW DIMENSION “D” TO PASS THRU.
SLIDE MULLION IN PLACE
DIM. “B” = JAMB DEPTH - FRAME GAUGE THICKNESSDIM. “D” = DETERMINED BY FACE DIMENSION
*
*
EQUAL TO FACE DIM. MINUS 1/4" (6.4)
2"(50.8)
1" (25.4)
“D”
ARC WELD2 PLACES MINIMUM
DIM “B”
DRILL 3/16" (4.8)2 HOLES
12-24 TAPSCREWS
INSTALLED
*
ANCHOR PART NUMBER: P0090
NOTE: THE MULLION WILL BE REMOVABLE FROM THE FACE OPPOSITE THE DOOR RABBET.
105Removable Horizontal Mullion / Bracket
FRAME TECHNICAL DATAApril 1, 2002ASSA ABLOY, the global leader
in door opening solutions
L
ATTACH MULLION BRACKET TO FRAME
NOTCH MULLION FACE TO ALLOWDIMENSION “D” TO PASS THRU.
SLIDE MULLION IN PLACE
DIM. “B” = JAMB DEPTH - FRAME GAUGE THICKNESSDIM. “D” = DETERMINED BY FACE DIMENSION
*
*
*
2 HOLES 3/16" (4.8)12-24 TAP PAN HEAD 1/2"SCREWS INSTALLED
“D”
1" (25.4)2"
(50.8)
EQUAL TO FACE DIM. MINUS 1/4" (6.4)
SPOT WELD2 PLACES MINIMUM
DIM “B”
12 GA. (2.6)
ANCHOR PART NUMBER: P0090
NOTE: INDICATE APPROPRIATE HAND OF ELEVATION AND WHICH SIDE OF ELEVATION MULLIONSHOULD BE REMOVABLE FROM.
106Splice Connection Head or JambFRAME TECHNICAL DATAApril 1, 2002 ASSA ABLOY, the global leader
in door opening solutions
L
Field Splice Connection with Bracket
L
1. FIT SPLICING SLEEVE REINF. HALFWAY INTO ONE SIDE AND TACK WELD IN PLACE.2. SLIP OTHER SIDE OVER SPLICING SLEEVE REINF. AND ALIGN SEAMS FOR STRAIGHTNESS.3. TACK WELD SPLICING SLEEVE REINF. INSIDE AND TACK WELD OUTSIDE SEAM AT BOTH FACES.4. CONTINUOUS WELD SEAM - GRIND AND FINISH SMOOTH.
12" (304.8)
12 GA. (1.9) SPLICING REINF.
ANCHOR PART NUMBER: P0155
12 GA. (2.6)FIELD SPLICING SLEEVE
ARC WELD INSIDE
ARC WELD INSIDE
FIELD SPLICE WITH BRACKETFIELD WELD & FASTEN WITH SCREWS
3" (76.2)
ANCHOR PART NUMBER: P0156
NOTES FOR LABELING PURPOSES:1) NOTCH SOFFIT OF ADJOINING PIECE.2) ARC WELD SPLICING SLEEVE BRACKET TO MULLION.3) FULL WELD FACES OF BOTH PIECES TOGETHER, OR
ATTACH WITH 3 #10 SCREWS THROUGH FACE INTO FIELD SPLICING SLEEVE BRACKET.
107KD Double Egress Frame Standards
FRAME TECHNICAL DATAOctober, 2007ASSA ABLOY, the global leader
in door opening solutions
LHANDING
LHRRH LH
RHR
DOUBLE RIGHT HAND SWING(STANDARD)
2
1
3 MEETING EDGE
5-3/4" (146.1) JAMB DEPTH HAS 7/16" (11.1) RETURN 18, 16, 14 GA.12 GA. 1/2" RETURN NO KD
2-5/8"(79.4)
4-3/4" (120.7) MIN.14" (355.6) MAX.
EQUAL
1-15/16"(49.2)
EQUAL
THROATOPENING
*1/2" (12.7)
*1/2" (12.7)
2" (50.8)
1-3/8" (34.9) 5/8" (15.9)
FINISHOPENINGWIDTH
1 JAMB
2 HEAD
THROATOPENING
1/2"(12.7)
1/2"(12.7)
2-5/8"(79.4)
4" (101.6) MIN.14" (355.6) MAX.
2"(50.8)
5/8" (15.9)
* *
*
M - FLUSH SERIES KDC - DRYWALL KD NOT AVAILABLE
3
3/32" (.094) CL HEAD
3/16" (.188)
SOFFIT STOP IS HELD BACK 3/32" TOPROVIDE PROPER DOOR CLEARANCE
108Lead Line ClipFRAME TECHNICAL DATANovember, 2004 ASSA ABLOY, the global leader
in door opening solutions
L
S.B.E. Double Egress Frame Corner Joints
L
1" (25.4)
1" (25.4)
1/2"(12.7)
16 GA. (1.4)
DOOR RABBET
16"(406.4)
CL
CL
STEEL CLIP IS BENT OVER TO RETAINLEAD LINING
DOOR RABBET
1-1/8" (28.6) MIN.
RETURN FILLER
RETURN FILLER
WELD
RETURN FILLER
VERTICAL BUTT JOINT(STANDARD)WELDED &GROUND SMOOTH
HORIZONTAL BUTTJOINT(OPTIONAL)WELDED &GROUND SMOOTH
109CCW - Open Back Rail - 10'6-5/8" Lengths
FRAME TECHNICAL DATANovember, 2004ASSA ABLOY, the global leader
in door opening solutions
L
6'8" (2032) LOCATION 3 HINGES C.C.W. 247'0" (2133.6) LOCATION 3 HINGES C.C.W. 257'2" (2184.4) LOCATION 3 HINGES C.C.W. 39
OPEN BACK RAILHINGE JAMB
7'10" (2387.6) LOCATION 4 HINGES C.C.W. 628'0" (2438.4) LOCATION 4 HINGES C.C.W. 639'0" (2743.2) LOCATION 4 HINGES C.C.W. 11910'0" (3048) LOCATION 4 HINGES C.C.W. 120
OPEN BACK RAILHINGE JAMB
FOR 1-3/4" (44.5) DOORS ALL STRIKE LOCATIONS 40" (1016)IF PUNCHED - SILENCERS ARE REQUIREDWHEN ORDERING CCW 26 STRIKE JAMB SPECIFY DOOR HEIGHT
OPEN BACK RAILSTRIKE JAMB
CL
NOTE: ANCHORS ARE NOT INCLUDED WITH CCW MATERIAL.CCW MATERIAL MAY BE ORDERED CUT TO LENGTH - EXACT LENGTH - WITHS.M.O. OR S.B.E. CORNER CONFIGURATION.CUSTOM PROFILES AVAILABLE.12 GA. FRAMES ARE CCW. 5-3/4 JAMB DEPTH HAS 1/2" RETURNS.
C.C.W. 26
10'6-5/8" (3216.3)
110CCW - Mullion Closed Section - 10'6-5/8" Lengths FRAME TECHNICAL DATANovember, 2004 ASSA ABLOY, the global leader
in door opening solutions
L
6'8" (2032) LOCATION 3 HINGES C.C.W. 427'0" (2133.6) LOCATION 3 HINGES C.C.W. 437'2" (2184.4) LOCATION 3 HINGES C.C.W. 44
MULLION - CLOSED SECTIONHINGE JAMB
7'10" (2387.6) LOCATION 4 HINGES C.C.W. 818'0" (2438.4) LOCATION 4 HINGES C.C.W. 829'0" (2743.2) LOCATION 4 HINGES C.C.W. 13310'0" (3048) LOCATION 4 HINGES C.C.W. 134
MULLION -CLOSED SECTIONHINGE JAMB
FOR 1-3/4" (44.5) DOORS ALL STRIKE LOCATIONS 40" (1016)IF PUNCHED - SILENCERS ARE REQUIREDWHEN ORDERING CCW 41 STRIKE JAMB SPECIFY DOOR HEIGHT
MULLION -CLOSED SECTIONSTRIKE JAMB
CL
C.C.W. 41
10'6-5/8" (3216.3)
12 GA. FRAMES ARE CCW
111CCW - Mullion Closed Section - 10'6-5/8" Lengths Communicating Mullion
FRAME TECHNICAL DATANovember, 2004ASSA ABLOY, the global leader
in door opening solutions
L
10'6-5/8" (3216.3)
MULLION - CLOSED SECTIONCOMBINATION RAILALL STANDARDDOOR HEIGHTS.
DOUBLE HINGE, DOUBLESTRIKE OR HINGE ANDSTRIKE COMBINATIONS.
6'8" (2032) LOCATION 3 HINGES & STRIKE C.C.W. 457'0" (2133.6) LOCATION 3 HINGES & STRIKE C.C.W. 467'2" (2184.4) LOCATION 3 HINGES & STRIKE C.C.W. 477'10" (2387.6) LOCATION 4 HINGES & STRIKE C.C.W. 838'0" (2438.4) LOCATION 4 HINGES & STRIKE C.C.W. 849'0" (2743.2) LOCATION 4 HINGES & STRIKE C.C.W. 13510'0" (3048) LOCATION OF 4 HINGES & STRIKE C.C.W. 136DOUBLE STRIKE MULLION C.C.W. 85NOTE: WHEN ORDERING CCW 85 SPECIFY DOOR HEIGHT.6'8" (2032) LOCATION 3 (DOUBLE HINGES) C.C.W. 867'0" (2133.6) LOCATION 3 (DOUBLE HINGES) C.C.W. 877'2" (2184.4) LOCATION 3 (DOUBLE HINGES) C.C.W. 887'10" (2387.6) LOCATION 4 (DOUBLE HINGES) C.C.W. 898'0" (2438.4) LOCATION 4 (DOUBLE HINGES) C.C.W. 909'0" (2743.2) LOCATION 4 (DOUBLE HINGES) C.C.W. 13710'0" (3048) LOCATION OF 4 (DOUBLE HINGES) C.C.W. 138
NOTE: WHEN ORDERING COMBINATION MULLION DOUBLE HINGE, DOUBLE STRIKE, OR HINGE AND STRIKE, PROVIDE SECTION DETAIL OF DOOR RABBETLOCATION.
EXAMPLE
12 GAUGE FRAMES ARE CCW
112CCW Sills - CCW 28, 139, 140, 48, 49, 55 - 10'6-5/8" LengthsFRAME TECHNICAL DATANovember, 2004 ASSA ABLOY, the global leader
in door opening solutions
L
4" (101.6)6" (152.4)8" (203.2)
JAMBDEPTH
FULL JAMB DEPTH 4" (101.6) FACE OR LESS C.C.W. 28FULL JAMB DEPTH 6" (152.4) FACE OR LESS C.C.W. 139FULL JAMB DEPTH 8" (203.2) FACE OR LESS C.C.W. 140
6-13/16" (173)
JAMBDEPTH
FULL JAMB DEPTH 6-13/16" (173) FACE C.C.W. 55
4" (101.6)6" (152.4)8" (203.2)
5/8" (15.9)
1-9/16" (39.7)
SPECIAL 1-9/16" (39.7) THICK C.C.W. 48
4" (101.6)6" (152.4)8" (203.2)
5/8" (15.9)
1-15/16" (49.2)
SPECIAL 1-15/16" (49.2) THICK C.C.W. 49
10'6-5/8" (3216.3)
12 GAUGE FRAMES ARE CCW
113CCW - Plain Mullion CCW 16, 17, 18, 50 - 10'6-5/8" Lengths
FRAME TECHNICAL DATANovember, 2004ASSA ABLOY, the global leader
in door opening solutions
L
10'6-5/8" (3216.3) 2" (50.8) FACE
JAMB DEPTH
PLAIN MULLION 2" (50.8) FACE C.C.W. 16
4" (101.6) FACE
JAMB DEPTH
PLAIN MULLION 4" (101.6) FACE C.C.W. 17
6" (152.4) FACE
JAMB DEPTH
PLAIN MULLION 6" (152.4) FACE C.C.W. 18
8" (203.2) FACE
JAMB DEPTH
PLAIN MULLION 8" (203.2) FACE C.C.W. 50
12 GAUGE FRAMES ARE CCW
114CCW - Plain Rail CCW 21, 23, 115, 117 - 10'6-5/8" LengthsFRAME TECHNICAL DATANovember, 2004 ASSA ABLOY, the global leader
in door opening solutions
L
10'6-5/8" (3216.3)2" (50.8) FACE
JAMB DEPTH
PLAIN RAIL 2" (50.8) FACE C.C.W. 21
JAMB DEPTH
PLAIN RAIL 4" (101.6) FACE C.C.W. 23
JAMB DEPTH
PLAIN RAIL 6" (152.4) FACE C.C.W. 115
4" (101.6) FACE
6" (152.4) FACE
JAMB DEPTH
PLAIN RAIL 8" (203.2) FACE C.C.W. 117
8" (203.2) FACE
12 GAUGE FRAMES ARE CCW
115Sill Reinforcement
FRAME TECHNICAL DATAAugust, 2003ASSA ABLOY, the global leader
in door opening solutions
LANCHOR PART NUMBER: P320
LOCATED EVERY 18" OF SILL LENGTH WHEN FACE EXCEEDS 5".PROVIDES ADDITIONAL SUPPORT TO PROFILE FACE.
2" (50.8)
1-1/2" (38.1)
12 GA. (2.6)
ONE STIFFENER EVERY 18" OFLENGTH ON FACE DIMENSIONS5" TO 9" FACE DIMENSIONS 9"THRU 16" MAX. REQUIRE TWOSTIFFENERS PER 18" OF LENGTH.
116CCW - Misc. Rail CCW 19, 27, 22, 29 - 10'6-5/8" LengthsFRAME TECHNICAL DATANovember, 2004 ASSA ABLOY, the global leader
in door opening solutions
L
JAMB DEPTH
COVER PLATECORNER OR FLAT
10'6-5/8" (3216.3)
C.C.W. 19
FILLER PLATE WITHOUT STOP
C.C.W. 27
FILLER PLATE WITH STOP
C.C.W. 22
HEAD CAP
C.C.W. 29
JAMB DEPTH
JAMB DEPTH
JAMB DEPTH
OR
CORNER
FLAT
12 GAUGE FRAMES ARE CCW
117CCW - Misc. Rail CCW 91, 92, 40 - 10'6-5/8" Lengths
FRAME TECHNICAL DATANovember, 2004ASSA ABLOY, the global leader
in door opening solutions
L
10'6-5/8" (3216.3)
JAMB DEPTH
JAMB DEPTH
JAMB DEPTH
CHANNEL HEAD REINF.
C.C.W. 91
FULL WIDTH HEAD REINF.
C.C.W. 92
CASED OPENING PLAIN RAILCASED OPENING PLAIN RAIL 4" (101.6)
C.C.W. 40 2" FACEC.C.W. 20 4" FACE
12 GAUGE FRAMES ARE CCW
118CCW - Corners CCW 51, 52, 53, 54, 10'6-5/8"FRAME TECHNICAL DATANovember, 2004 ASSA ABLOY, the global leader
in door opening solutions
L
JAMB DEPTH
1-15/16"(49.2)
1-9/16"(39.7)
2 WAY CORNER1-9/16" (39.7) OUTSIDE
C.C.W. 51
JAMB DEPTH
1-15/16"(49.2)
1-9/16"(39.7)
JAMB DEPTH
1-15/16"(49.2)
1-9/16"(39.7)
2 WAY CORNER1-15/16" (49.2) OUTSIDE
C.C.W. 52
JAMB DEPTH
1-15/16"(49.2)
1-9/16"(39.7)
JAMB DEPTH
1-15/16"(49.2)
1-9/16"(39.7)
3 WAY CORNER1-9/16" (39.7) OUTSIDE
C.C.W. 53
JAMB DEPTH
1-15/16"(49.2)
1-9/16"(39.7)
1-15/16"(49.2)
1-9/16"(39.7)
JAMB DEPTH
1-15/16"(49.2)
1-9/16"(39.7)
3 WAY CORNER1-15/16" (49.2) OUTSIDE
C.C.W. 54
JAMB DEPTH
1-15/16"(49.2)
1-9/16"(39.7)
1-15/16"(49.2)
1-9/16"(39.7)
12 GAUGE FRAMES ARE CCW
119CCW - Glass Stop
FRAME TECHNICAL DATANovember 15, 2004ASSA ABLOY, the global leader
in door opening solutions
L
CCW# HEIGHT X WIDTH DESCRIPTION93 5/8" (15.9) X 5/8" (15.9) PRIME PAINT - PUNCHED 12" (304.8) ON CENTER97 5/8" (15.9) X 5/8" (15.9) PRIME PAINT - BLANK101 5/8" (15.9) X 5/8" (15.9) NO PAINT - BLANK105 5/8" (15.9) X 5/8" (15.9) NO PAINT - PUNCHED 12" (304.8) ON CENTER
94 5/8" (15.9) X 1" (25.4) PRIME PAINT - PUNCHED 12" (304.8) ON CENTER98 5/8" (15.9) X 1" (25.4) PRIME PAINT - BLANK102 5/8" (15.9) X 1" (25.4) NO PAINT - BLANK106 5/8" (15.9) X 1" (25.4) NO PAINT - PUNCHED 12" (304.8) ON CENTER
95 3/4" (19) x 5/8" (15.9) PRIME PAINT - PUNCHED 12" (304.8) ON CENTER99 3/4" (19) x 5/8" (15.9) PRIME PAINT - BLANK103 3/4" (19) x 5/8" (15.9) NO PAINT - BLANK107 3/4" (19) x 5/8" (15.9) NO PAINT - PUNCHED 12" (304.8) ON CENTER
96 3/4" (19) X 1" (25.4) PRIME PAINT PUNCHED 6" (152.4) ON CENTER100 3/4" (19) X 1" (25.4) PRIME PAINT - BLANK104 3/4" (19) X 1" (25.4) NO PAINT - BLANK108 3/4" (19) X 1" (25.4) NO PAINT - PUNCHED 6" (152.4) ON CENTER
143 1" (25.4) X 1" (25.4) - PRIME PAINT - PUNCHED 6" (152.4) ON CENTER
GLASS STOP IS MANUFACTURED FROM GALVANEALED STEEL. PAINT IS CURRIES STANDARD GRAY PRIME. PUNCHING IS FOR OVAL HEAD SCREWS SIZE #8.
NOTE: HOLE PUNCHING ON GLASS STOP IS STANDARD 12" (304.8) ON CENTER. IF STOP IS TO BE USED FOR LABEL FRAME APPLICATIONS YOU MUST SPECIFY ON ORDER THAT HOLES ARE TO BE 6" (152.4) ON CENTER.
ALL GLASS STOP AND SOFFIT STOP MATERIAL COME IN 10'6" (3200.4) LENGTHS
STAINLESS STEEL GLASS STOP IS 16 GA. (1.4)
5/8"(15.9)
5/8"(15.9)
5/8"(15.9)
1"(25.4)
3/4"(19)
5/8"(15.9)
3/4"(19)
1"(25.4)
1"(25.4)
1"(25.4)
9/32" (7.1)
16 GA.
16 GA.
16 GA.
18 GA.
18 GA.
120CCW - Shipping Spreader Bar CCW 111 - 10'6-5/8"FRAME TECHNICAL DATAApril 1, 2002 ASSA ABLOY, the global leader
in door opening solutions
L
TACK WELD SHIPPING SPREADER BAR TO BOTTOM OFFRAME RABBET INSIDE NOMINAL FRAME OPENING.
TOP VIEW LOOKING DOWN
3/8" (9.5)
1" (25.4)
NOTE: CURRIES HOLLOW METAL FRAMES HAVE DOUBLE SHIPPING SPREADERBARS WELDED ON THE BOTTOM. THE SPREADER BARS MUST BE REMOVED AND ASETTING SPREADER USED FOR FINAL INSTALLATION. A COLD CHISEL AND HAMMER ARE RECOMMENDED TOOLS TO USE TO REMOVE THESE. THE FRAMEINSTALLER ASSUMES ALL RESPONSIBILITY FOR PLUMB FRAME INSTALLATION.
121Custom Frame Profiles
FRAME TECHNICAL DATAOctober, 2003ASSA ABLOY, the global leader
in door opening solutions
LCONTACT FACTORY FOR CAPABILITIES
3/4" (19.1)MINIMUM
1" (25.4)MINIMUM
3/8" (9.5)MINIMUM
289 3/4" (19.1)MINIMUM
1" (25.4)MINIMUM
1/2" (12.7)MINIMUM
B
3/8" (9.5)MINIMUM
VARIES
VARIES
1/8" (3.2) 16 GA. (1.4)MINIMUM
F
5/32" (4) 14 GA. (1.9)MINIMUM
NOTE: FOR 12 GA. (2.6) CONTACT FACTORY
122Custom Frame ProfilesFRAME TECHNICAL DATAJuly 1, 2003 ASSA ABLOY, the global leader
in door opening solutions
L
3/4" (19.1)MINIMUM
1-1/2" (38.1)MINIMUM
2" (50.8)MAXIMUM
H
JAMBDEPTH
1/2" (12.7)MINIMUM
NOTE THROAT OPENINGWHEN ORDERING
1/2" (12.7) RADIUS ONLY
1/2" (12.7)
3/4" (19.1)MINIMUM
1" (25.4)MINIMUM
2" (50.8)MAXIMUM
L
1/2" (12.7)MINIMUM
1/2" (12.7)
3/8" (9.5)MINIMUM
3/4" (19.1)MINIMUM
1" (25.4)MINIMUM
1/8" (3.2) 16 GA. (1.4)3/16" (4.8) 14 GA. (1.9)
I
NOT 12 GA. (2.6)
16 GA. ONLY
1/2" (12.7)ONLY
1/2" RADIUS
1/4" (6.4)ONLY
275
16 GA. ONLY3-1/2" MIN. (88.9)14" MAX. (355.6)
125StormPro® 361 Frame Construction
FRAME TECHNICAL DATAMay, 2007
L
ASSA ABLOY, the global leaderin door opening solutions
SINGLE
A
B
B
B
A
C
DOUBLE
2" (50.8)or 4" (101.6)
1/2" (12.7)1/2" (12.7)
2" (50.8)
5-3/4"(146)
OUTSWINGONLY
OUTSWING
ONLY
OU
TSWIN
G
ON
LY
2" (50.8)
1/2" (12.7)1/2" (12.7)
FRAMES ARE 16 GAUGE (1.4) A60, KD ORFACE WELDED CORNER CONSTRUCTION
SARGENT HC980 MULLION REQUIRED ONPAIRS OF DOORS
B
BA
5-3/4" (146) MIN.14" (355.6) MAX.
5-3/4" (146) MIN.14" (355.6) MAX.
FRAMES MUST BE INSTALLED ANDANCHORED PER SHOP DRAWINGS.WALLS CONSTRUCTED AS DESCRIBED INFEMA 361 (DESIGN AND CONSTRUCTIONGUIDANCE FOR COMMUNITY SHELTER)
126Steel Channel Anchor Installation - Drywall Return FrameFRAME TECHNICAL DATAAugust 1, 2002
L
ASSA ABLOY, the global leaderin door opening solutions
TWIST 45˚ TOCLEAR THE RETURNS.
TWIST THE ANCHORUPRIGHT.
ROTATE THEANCHOR CLOCKWISE TOTIGHTEN IN THEPROFILE.
ROTATE TO GET THEANCHOR LEGSUNDER THE PROFILE RETURNS.
ROTATE ANCHOR 45˚TO CLEAR RETURNS.SLIDE INTO PROFILE.
ANCHOR PART NUMBER: PO149
127Door Silencers
FRAME TECHNICAL DATAOctober 1, 2002ASSA ABLOY, the global leader
in door opening solutions
TOP OFSTRIKE
CUTOUT
SILENCERS
8" (203.2)
10" (254)
2" (50.8)
SINGLE DOORFRAME
SILENCERS
CL
5" (127)
5" (127)
PAIR OF DOORS FRAME
ADHESIVE TYPE
ADHESIVE BACKED SILENCERSFIELD APPLIED AFTER FINISH PAINTING
PUNCH TYPE
17/64" (6.8) DIA. HOLETO ACCEPT PUSH IN
TYPE SILENCERS
17/64" (6.8) 5/8" (15.9)
ADHESIVEBACKING
128Loose Spline SleeveFRAME TECHNICAL DATASeptember, 2003 ASSA ABLOY, the global leader
in door opening solutions
JAMB DEPTH-5/16" (7.9)
4" (101.6)
PART #P20016 (1.4) GA.
4 SPOTWELDS
16 GA. (1.4)
PART #P200
L
129Recommended Erection Instructions
FRAME TECHNICAL DATAJuly 1, 2003ASSA ABLOY, the global leader
in door opening solutions
NOTE: Shipping bars should not be used asspreader. Remove shipping bar before settingframe.
Plumbing the frameThe contractor should be equipped with a car-penter level, square and spreader. Set the framein desired location and level the header. Squarejambs to header. Shim under jambs if necessary.With frame on line, set spreader and fastenjambs to floor through floor anchors.
BR
AC
ING
FRA
ME
SB
EFO
RE
WA
LLC
ON
STR
UC
TIO
NN
EW
MA
SO
NR
YC
ON
STR
UC
TIO
N
Bracing the frameBrace the frame as shown orshore to a structure above.Brace In The Direction OfIntended Wall. Plumb andsquare jambs. Install verticalbrace to support header foropenings over 4'0" wide.
SpreaderTypical wood spreader must be square and fabricatedfrom lumber no less than 1" thick. Correct length is thedoor opening width between the jambs at the header(i.e., Single Door 3'0" = 36"). Cut clearance notches forframe stops. Spreader must be nearly as wide as framedepth for proper installation.
A A
SPREADER
SECTION A-A
LEVEL
SQUARE
PLU
MB
DOOR OPNG. AT HEADER
FRA
ME
DE
PTH
1. Assemble frame.
2. Set brace and plumb frame.
3. Install anchors. Grout frame in the area of the anchors (see above)as block courses are laid up. Frames may also be supplied withanchors welded in place.
4. A second spreader isrecommended at themid point of the dooropening to maintainthe door openingdimension.
5. Continually checkplumb and square aswall progresses.
WireAnchor
“T”Anchor
90˚ 90˚
SPREADER
NOTE: Anchors in frame heads are not required.
130Recommended Erection InstructionsFRAME TECHNICAL DATAJuly 1, 2003
STE
EL
STU
DW
ALL
CO
NS
TRU
CTI
ON
WO
OD
STU
DC
ON
STR
UC
TIO
NW
OO
DS
TUD
CO
NS
TRU
CTI
ON
(STU
DS
ER
EC
TED
BE
FOR
EFR
AM
E)
Elevation1. Assemble frame.2. Install anchors. Position anchors in frame through the
throat and tap in with a hammer. Frames may also besupplied with anchors welded in place.
3. Square, brace and plumb frame as shown.4. Set spreader. Attach jambs to floor through floor anchor
or floor extension. Install jamb studs to floor and ceilingrunners and tightly against frame anchors.
5. Attach studs to frame anchors as shown.
NOTE: Drywall mustextend at least 1/2"into frame at firerated installations.
Channel type steel studPosition studs in frame throat and attach to anchors with screws orweld. If using screws, the installer should drill from the back side ofthe stud, through both the stud and anchor, then attach with (2)screws per anchor location.NOTE: When attaching header stud to jamb studs, be sure the studis above frame header. This will assure ample room for attachingplaster lath or drywall and will not interfere with installation of hardware attached to frame header. Anchors are not required inframe heads, except fire listed double egress openings.
FRAME
CHANNELTYPEJAMBSTUDS
HEADER STUD
JAMBSTUD
SPREADER
90˚ 90˚
Erect frameAssemble frame. Stand frame up in desired loca-tion. Anchor one jamb to floor and set spreaderon floor from anchored jamb to loose jamb.Position and anchor second jamb. Plumb, leveland square frame, then brace.
NOTE: Drywall must extend at least 1/2" intoframe at fire rated installations.
1. Install anchors. Position anchors in frame throat and tap in with a hammer. Frames may also be sup-plied with anchors welded in place.
2. Set spreader.Attach jambs to floor through floor anchor or
floor extension. Install double jamb studs to floor and ceiling runners and header.
3. Bend anchor tabs around stud leaving desired clearance between frame return and stud for inserting finished wall material.
4. Square and nail top anchor to stud on ONE JAMB ONLY.Check plumb and square and continue to nail balance of anchors to stud. Repeat for opposite jamb.
5. Anchors are not required in frame heads, except fire listed double egress openings.
ANGLEBRACES
SPREADER
FRAME
WOODSTUDS
FLOORRUNNER
JAMBSTUD
HEADER STUD
SPREADER
90˚ 90˚
Rough openingBuild rough opening. Rough openingdimensions for 2" face frames should be 4-1/4" - 4-1/2" larger than door width and2-1/4" - 2-1/2" larger than door height. It isrecommended that double studs be used atjambs and headers.NOTE: Drywall must extend at least 1/2"into frame at fire rated installations.
1. Assemble frame.2. Install anchors. Position
anchors in frame throat and tap in with a hammer.Frames may also be supplied with anchors welded in place. Base anchors may also be used. If base anchor cannot be used add one anchor per jamb at bottom.
3. Place frame in rough stud opening.
4. Bend anchor tabs around stud leaving desired clearance between frame return and stud for inserting finished wall material.
5. Set spreader and level frame. Shim jambs if necessary.6. Square and nail top anchor to stud on ONE JAMB ONLY. Check plumb and
square and continue to nail balance of anchors to stud. Repeat for opposite jamb.
7. Anchors are not required in frame heads, except fire listed double egress openings.
ROUGHOPENING
DIMENSIONS
SPREADER
90˚ 90˚WOODSTUDS
FRAME
JAMB STUD
131ElectroLynxTM System LX Options
FRAME TECHNICAL DATAASSA ABLOY, the global leaderin door opening solutions
May, 2005
The CURRIES LX cable is equipped with the ElectroLynxTM System of “plug-in” connectors for fast, easy, connec-tion to similarly equipped ASSA ABLOY Hardware. The LX cable has 15 conductors of 22 gauge wire in a PVCjacket, with ElectroLynx snap connectors on the hardware prep end only.
KD FRAMES – (LX) are provided with a cover box and a conduit knockout over the electric hingeprep(s), electric strike prep, and junction box in the frame head including a 1" access knockout. ElectroLynx (LX) wiring system cable(s) are included. Conduit option is loose or by others, as specified when ordered.
FACTORY – (LX) are provided with the same cover box options listed above for KD frames, WELD FRAMES conduit is included and the LX cable is installed with the ElectroLynx system in
place as ordered. The frame head junction box has electrical knockout for building wiring, and the frame head rabbet has a 1" knockout for future installation of Door Position Switch under the cover box.
– Check anchor interference with conduit, some loose anchor styles won’t work.– Some electric preps won’t allow 1/2" drywall penetration for fire rated frames.
“Hardwiring Made Easy”
6" 6" 6"CL CL CL
SECONDELECTRICHINGE IFNEEDED
HJ SJ HJ SJ HJ SJ
132CURRIElum Emergency Egress FrameFRAME TECHNICAL DATAMarch 1, 2005 ASSA ABLOY, the global leader
in door opening solutions
2-13/16"(71.4)
MINIMUMFACE
1-3/4"(44.4)
MINIMUM
NOTE: JAMB DEPTH MUST BE 1-1/8" LARGER THAN THETHROAT OPENING OR WALL THICKNESS. A 4-3/4" WALLWILL REQUIRE A 5-7/8" JAMB DEPTH FRAME.
ELECTROLUMINECENTLAMP
RACEWAY
RACEWAYENDCAP
RACEWAY ACCESSKNOCKOUT
LITEGUIDE ELECTRICALACCESS 1-1/4" (31.7)
“KNOCKOUT”5" (127) CL AFF
HOLE PLUG4"
(101.6)
6" (152.4)
THROAT IS 1-1/8" LESSTHAN JAMB DEPTH
9/16"(14.3)
9/16"(14.3)
DRYWALL RETURNPROFILE 299
MASONRY RETURNPROFILE 301
NOTE: A FULL WIDTH JUNCTION BOX IS PROVIDEDAT THE BOTTOM OF EACH JAMB. USE OF SWING-ING DOOR HARDWARE MOUNTED IN THE BOTTOM10” OF FRAME IS NOT AVAILABLE. HOLE PLUGAND ENDCAPS ARE SHIPPED LOOSE.
ASSA ABLOY, the global leaderin door opening solutions
133Security Sidelite Door Construction
FRAME TECHNICAL DATAMarch, 2007
FEATURES:
HINGED SECURITY PANELCLOSES TO CREATE A VISUALBARRIER
GLASS POCKETS AVAILABLEFOR UP TO 1” THICK GLASS
PREPARED FOR SELF LATCH-ING DEADBOLT TO MEETPROJECT REQUIREMENTS
STANDARD 4-1/2” X .134HINGE PREPARATIONS
OPTIONS:
AVAILABLE WITH MASONRYAND STUD WALL ANCHORS
FIRE RATING:WARNOCK HERSEY3/4 HOUR RATING. (1-1/2 HOUR WITH SPECIALTYGLAZING)
USES:• CLASSROOMS• POST OFFICES• GOVERNMENT FACILITIES• AIRPORTS
16 OR 14 GA. FRAMES WITHWELDED CORNERS 6-3/4" MINIMUM DEPTH
OPERABLEPANEL
INSIDESECTIONOUTSIDE
GLASS
134Transom Frame Removable Panel InstallationFRAME TECHNICAL DATAJuly, 2007
L
ASSA ABLOY, the global leaderin door opening solutions
16 GAUGE GUIDECHANNEL
TOP OF PANELNOTCHED FOR GUIDE CHANNELS
BOTH FACE SHEETSWELDED TO VERTICAL END CHANNELS, 6"O.C.
3/8" RETAINER PINS FOR REMOVABLE PANELS:WELDED TO INSIDE OF HEAD.6" FROM ENDS 18" MAX O.C.
TAPPED FOR1/4-20 MS
1/4" STEELPLATE
HORIZONTAL EDGES OFPANEL ARE WELDED TOCONTINUOUS CHANNEL
NOMINAL 1-3/4" THICK
1/4" STEEL PLATEWITH CLEAR HOLE
16 GAUGEGUIDE (END)CHANNELSBOTH SIDES
1/4-20 FHMS (2)
JAMB
TOP OF PANELBOTTOM OF PANEL
1-9/16"
7/8"
DRILL 1/4" AND COUNTERSINK
DOOR OPENING17/32" TO BOTTOMOF PANEL & 1/8"CLEARANCE TO TOPOF DOOR FROM BOTTOM OF PANEL
48" MAX.PANELHEIGHT
HORIZONTAL ASTRAGALREQUIRED.
PANEL - STEEL STIFFENED, MINERALCORE OR HONEYCOMB.
FRAME - 3 HR MAX. RATING11'4" MAX. HEIGHT4' MAX. WIDTH SINGLE8' MAX. WIDTH PAIR