Frame 9e Gas Turbine Plant2

12
For Further Information, please contact GTI: www.GTI-Power.com Stan Green Larry Rayman [email protected] [email protected] Tele: +1-312-371-9999 Tele: +1-561-414-9696 Two GE Frame 9E Power Plants 2 EACH GE FRAME 9E, PG9161, MS9001 Take advantage of our current availability Financing can be arranged Priced at a fraction of new Gas Turbines International, LLC. (GTI) is offering for sale 2 each GE PG9161 Frame 9E Power Packages. 50 HZ, 116.4 MW, each Dual Fuel, Low Hours, Complete BOP, & Includes 2 Transformers. GTI’s Power Generation Services: •Complete Power Plant Installations •Supply, Install and Commission •Operation & Maintenance •Specialist Agreement for Gas Turbine and Balance of Plant •Plant Rehabilitation & Relocation •Training •Complete Engineering & Design Capabilities Financial Strength •OEM Support •Refurbished and Warranted •Turnkey Visit us on our website: www.GTI-Power.com Date of Manufacture- 1992 Total Hours Fired- 15,000 Total Starts- 800

Transcript of Frame 9e Gas Turbine Plant2

Page 1: Frame 9e Gas Turbine Plant2

For Further Information, please contact GTI: www.GTI-Power.com

Stan Green Larry Rayman

[email protected] [email protected]

Tele: +1-312-371-9999 Tele: +1-561-414-9696

Two GE Frame 9E Power Plants 2 EACH GE FRAME 9E, PG9161, MS9001

Take advantage of our current availability

Financing can be arranged

Priced at a fraction of new

Gas Turbines International, LLC. (GTI) is offering for sale 2 each GE PG9161

Frame 9E Power Packages. 50 HZ, 116.4 MW, each Dual Fuel, Low Hours,

Complete BOP, & Includes 2 Transformers.

GTI’s Power Generation Services: •Complete Power Plant Installations •Supply, Install and Commission •Operation & Maintenance •Specialist Agreement for Gas Turbine and Balance of Plant •Plant Rehabilitation & Relocation •Training •Complete Engineering & Design Capabilities •Financial Strength •OEM Support •Refurbished and Warranted

•Turnkey

Visit us on our website: www.GTI-Power.com

Date of Manufacture- 1992 Total Hours Fired- 15,000 Total Starts- 800

Page 2: Frame 9e Gas Turbine Plant2

For Further Information, please contact GTI: www.GTI-Power.com

Stan Green Larry Rayman [email protected] [email protected] Tele: +1-312-371-9999 Tele: +1-561-414-9696

GE Frame 9E Gas Turbine Plant 2 EACH GE FRAME 9E, PG9161, MS9001

Rated Output (Generator Terminals) MW 116.4 per Unit

MS9001 RATINGS NATURAL GAS DISTILLATE BASE PEAK BASE PEAK OUTPUT- MW 116.4 125.7 114.2 123.3 HEAT RATE-Kcal/kWh (LHV) 2608 2598 2631 2621 HEAT RATE- Btu/kWh (LHV) 10350 10310 10440 10400

SCOPE OF SUPPLY Gas Turbine with essential auxiliaries, Gas Turbine Control System Generator, Starter Device and all auxiliary equipment Excitation and excitation control equipment Gas Supply line and valves from gas receiving station Gas Emergency stop valve, governor valve and actuators Gas Vent stack, Distillate supply pipeline and valves for connecting into overland supply Lubricating oil main pump AC driven pump, DC Driven pump, Jacking oil pump Lubricating oil tanks, filters, coolers and purifiers Clean oil tank and pipe work All pipework and valves for lube system Cooling water system including pumps, filters, coolers, fans, pipework and valves Air intake filters, silencer, ductwork and ancillary equipment Exhaust gas ductwork and silencer Exhaust stack, Auxiliary drive gear unit Automatic barring and inching gear Control oil supply including pumps, filters, valves, actuators and pipework Gas Generator protection equipment Plant supervisory and condition monitoring equipment Pressure, temperature, vibration and flow measuring instrumentation Local instruments, gauges, controls and panels Gas Turbine enclosure and ventilation equipment Gas Detectors and display panel Special maintenance tooling Full set of Manuals Plant drawings

Page 3: Frame 9e Gas Turbine Plant2

For Further Information, please contact GTI: www.GTI-Power.com

Stan Green Larry Rayman [email protected] [email protected] Tele: +1-312-371-9999 Tele: +1-561-414-9696

GE Frame 9E Gas Turbine Plant 2 EACH GE FRAME 9E, PG9161, MS9001

TECHNICAL PARTICULARS GAS TURBINE GENERAL DATA

Gas Turbine Model PG9161

Power Output (Generator Terminals MW 116.4

Efficiency (Referred to Generator Terminals) % 33

Rotor Speed RPM 3000

Direction of Rotation (looking From Generator) CLOCKWISE

Number of Compressor Stages 17

Temperature at Air Intake °C 15

Atmospheric Pressure bar 1.013

Pressure Drop up to Compressor Inlet mbar 10

Compressor Pressure Ratio 11.6

Compressor Exhaust Temperature °C 343

Compressor Efficiency % PROPRIETARY

Variable Geometry Stages 1

Air Bleed-off Stages 2

Number of Combustion Chambers 14

Dual Fuel System Yes

Fuel Nozzles/ Combustor 1

Ignition System Spark Plug

Combustion Wall Temperature °C PROPRIETARY

Fuel Consumption Kg/S 11.4

Method of NOx Reduction (Alternative Offer) WATER INJECTION

Number of Turbine Stages 3

Date of Manufacture 1992

Total Fired Hours 15,000

Total Starts 800

Page 4: Frame 9e Gas Turbine Plant2

For Further Information, please contact GTI: www.GTI-Power.com

Stan Green Larry Rayman [email protected] [email protected] Tele: +1-312-371-9999 Tele: +1-561-414-9696

GE Frame 9E Gas Turbine Plant 2 EACH GE FRAME 9E, PG9161, MS9001

Page 5: Frame 9e Gas Turbine Plant2

For Further Information, please contact GTI: www.GTI-Power.com

Stan Green Larry Rayman [email protected] [email protected] Tele: +1-312-371-9999 Tele: +1-561-414-9696

GE Frame 9E Gas Turbine Plant 2 EACH GE FRAME 9E, PG9161, MS9001

Page 6: Frame 9e Gas Turbine Plant2

For Further Information, please contact GTI: www.GTI-Power.com

Stan Green Larry Rayman [email protected] [email protected] Tele: +1-312-371-9999 Tele: +1-561-414-9696

GE Frame 9E Gas Turbine Plant 2 EACH GE FRAME 9E, PG9161, MS9001

Page 7: Frame 9e Gas Turbine Plant2

For Further Information, please contact GTI: www.GTI-Power.com

Stan Green Larry Rayman [email protected] [email protected] Tele: +1-312-371-9999 Tele: +1-561-414-9696

GE Frame 9E Gas Turbine Plant

2 EACH GE FRAME 9E, PG9161, MS9001

OUTPUT: KVA 150625 TYPE: BRUSH TURBO-GENERRATOR

R/MIN: 3000 FRAME: BDAX9-450PRH

VOLTS: 14000 MACHINE NO: 37694A-1G

AMPS: 6211 RATING: CONTINUOUS

P.F: 0.800 SPEC: BS 5000 PT II

PHASES/HZ: 3/50 AMBIENT TEMP: 15.0°C

PHASE CONN: STAR ALTITUDE: UP TO 1000 M

EXCITER VOLTS: 180 COOLANT: WATER AT 24°C

EXCITER AMPS: 1540 ROTOR INSULATION: CLASS F

DATE: 1990 STATOR INSULATION: CLASS F

1. Distillate inlet. Sale will include tanks if wanted. 2. Gas termination at fire shut off valve on the upstream side (fuel gas meters are not included). 3. Air inlets are included 4. Gas exhaust includes the chimneys. 5. Electrical termination.

A) 132/14KV Transformer on 132KV bushing. This allows synch on 3GO/4GO with Generator Transformer back energised.

B) Essential Services Boards 1 and 2 remain allowing purchaser to take Essential Services Boards 3 & 4.

C) Station Boards 1 and 2 remain allowing purchaser to take Unit Boards 3 and 4 D) Unit Transformers 3 and 4 are included in the sale.

E) Generator Transformers 3 and 4 are included in the sale

Page 8: Frame 9e Gas Turbine Plant2

For Further Information, please contact GTI: www.GTI-Power.com

Stan Green Larry Rayman [email protected] [email protected] Tele: +1-312-371-9999 Tele: +1-561-414-9696

ESTIMATED PERFORMANCE

GE FRAME 9E GAS TURBINE, PG9161, MS9001

BASE LOAD FUEL: NATURAL GAS ALTITUDE A- SEA LEVEL

MODE: SIMPLE CYCLE B-500m

INLET LOSS: 8.89cm H₂O C-1,000m

EXHAUST LOSS: 12.7cm H₂O D-1,500m

90

80

100

110

120

130

140

A

B

C

D

POWER OUTPUT, MEGAWATTS

50 40 30 20 10 0 -10

AMBIENT TEMPERATURE, deg C.

Page 9: Frame 9e Gas Turbine Plant2

For Further Information, please contact GTI: www.GTI-Power.com

Stan Green Larry Rayman [email protected] [email protected] Tele: +1-312-371-9999 Tele: +1-561-414-9696

ESTIMATED PERFORMANCE

GE FRAME 9E GAS TURBINE, PG9161, MS9001

BASE LOAD FUEL: NATURAL GAS ALTITUDE A- SEA LEVEL

MODE: SIMPLE CYCLE B-500m

INLET LOSS: 8.89cm H₂O C-1,000m

EXHAUST LOSS: 12.7cm H₂O D-1,500m

900

50 40 30 20 10 0 -10

1000

1100

1200

1300

1400

1500

HEAT CONSUMPTION,

KJ/HR X 10⁶(LHV)

AMBIENT TEMPERATURE, deg C.

A

B

C

D

Page 10: Frame 9e Gas Turbine Plant2

For Further Information, please contact GTI: www.GTI-Power.com

Stan Green Larry Rayman [email protected] [email protected] Tele: +1-312-371-9999 Tele: +1-561-414-9696

ESTIMATED PERFORMANCE

GE FRAME 9E GAS TURBINE, PG9161, MS9001

BASE LOAD FUEL: DISTILLATE ALTITUDE A- SEA LEVEL

MODE: SIMPLE CYCLE B-500m

INLET LOSS: 8.89cm H₂O C-1,000m

EXHAUST LOSS: 12.7cm H₂O D-1,500m

80

90

100

110

120

130

140

POWER OUTPUT, MEGAWATTS

A

B

C

D

50 40 30 20 10 0 -10

AMBIENT TEMPERATURE, deg C.

Page 11: Frame 9e Gas Turbine Plant2

For Further Information, please contact GTI: www.GTI-Power.com

Stan Green Larry Rayman [email protected] [email protected] Tele: +1-312-371-9999 Tele: +1-561-414-9696

ESTIMATED PERFORMANCE

GE FRAME 9E GAS TURBINE, PG9161, MS9001

BASE LOAD FUEL: DISTILLATE ALTITUDE A- SEA LEVEL

MODE: SIMPLE CYCLE B-500m

INLET LOSS: 8.89cm H₂O C-1,000m

EXHAUST LOSS: 12.7cm H₂O D-1,500m

9002

2 50 40 30 20 10 0 -10

1000

1100

1200

1300

1400

1500

HEAT CONSUMPTION,

KJ/HR X 10⁶(LHV)

AMBIENT TEMPERATURE, deg C.

A

B

C

D

Page 12: Frame 9e Gas Turbine Plant2

For Further Information, please contact GTI: www.GTI-Power.com

Stan Green Larry Rayman [email protected] [email protected] Tele: +1-312-371-9999 Tele: +1-561-414-9696

FRAME SIZE: BDAX.9-450 PRH ENCLOSURE: CACW

1. RATING

Output MVA 150.625 at 34°C cooling air

Power Factor 0.8

Voltage kV 14

Frequency Hz 50

Speed rpm 3000

Specification BS5000 Pt.2 & IEC 34.3

2. REACTANCES to a base of 150.625MVA (Calculated)

Synchronous Reactance Xdi 230%

Transient Reactance X'dr 22%

Sub-Translent Reactance X''dr 13.4%

Negative Sequence Reactance X2i 16.25%

3. CURVES Issue

Output/Coolant Temperature H.E.P. 7033 2

Reactive Capability Diagram H.E.P. 7381 1

Open Circuit/Short Circuit H.E.P. 7695 1

Efficiency H.E.P. 4512 5

Negative Sequence Capability H.E.P. 7694 1

4. RECOMMENDED ALARM AND TRIP SETTINGS

Alarm Trip Alarm Trip

Stator Winding Temp °C 150 160 Exciter Air Outlet Temp °C 105 -

Bearing Oil Outlet Temp °C 87 90 Bearing Housing mm/sec *Vibration Peak Velocity inches/sec

Peak to Peak Displacement mm

9 0.35 0.1

19 0.75 0.15 T.P.J. Metal Temp °C 105 110

Generator Air Outlet Temp °C 105 - Shaft Relative Vibration inches X10¯³ 4 6

*If vibration is measured in terms of amplitude:

Zero to peak amplitude (µm)= peak velocity (mm/sec) X 9550

R.P.M.