Performance Based ProductsBGC Fire-Resistant Plasterboard Installation Design Guide
Fire-Resistant PlasterboardPartition Systems
MANUALBGC PB-FR 203 SEPTEMBER 2004
PlasterboardFibre Cement
Head Office Perth WALot 80, Bushmead Road, Hazelmere, Western Australia, 6055
Telephone: (08) 9374 2900 Facsimile: (08) 9374 2901Postal Address: P.O. Box 1994, Midland DC, Western Australia 6936
Adelaide978 Port Road, Albert Park, South Australia, 5014
Telephone: (08) 8347 0844 Facsimile: (08) 8347 3122
Melbourne200 - 238 Maidstone Street, Altona, Victoria 3018
Telephone: (03) 9392 9444 Facsimile: (03) 9392 9404
Sydney32 - 34 Pine Road, Yennora, New South Wales 2161
Telephone: (02) 9632 2100 Facsimile: (02) 9632 2144
Brisbane39 Gardens Drive, Willawong Queensland 4110
Telephone (07) 3711 4744, Facsimile (07) 3711 4666
WarrantyBGC warrants its products to be free from defects caused by faultymanufacture or materials. If any of its products are so defective theCompany will at its option, repair or replace them, supply equivalent
replacement or reimburse the purchase price.
This warranty shall not apply to any loss or consequential loss sufferedthrough or resulting from defects caused by faulty manufacture or materials.
The propriety joint and coating systems are outside the control of BGC,therefore the independent joint and coating manufacturers must give all
warranties for the jointing system performance.
For More InformationBGC Branch Officeswww.bgcplasterboard.com.au
Produced by BGC Plasterboard ABN 62 005 736 005 020
™ Denotes a trademark owned by BGC Australia Pty Ltd.
Supersedes all previous publications.
A Product of Advanced TechnologyAustralian Owned
& Manufactured
Page 15
Fixing Specifications
First Layer
Fastener Spacing Location
Nails or Screws600mm max. centres
Centre of the Board
Nails or Screws600mm max. centres
Recessed Edges
Nails or Screws600mm max. centresin staggered pattern
Fastener Spacing Location
2 Nails 50mm apart at300mm max. centres
1 screw at 200mmmax. centres
At Each Stud
Nails at 150mm max.centres
Screws at 200mmmax. centres
Nails at 150mm max.centres
Screws at 300mmmax. centres
Centre of the Board
Recessed Edges
Butt Joints
Corners & Openings
Second Layer
Butt Joints
BGC 16mm FireResistant PlasterboardFix Two (2) Layers (1st
Vertical - 2nd Horizontal)In Staggered Lay-out
to Each Face of Frame
75 x 45 Top Plate
Caulk Perimeter with Fire-Rated Mastic
Nog
ging
at
1350
mm
Max
. Cen
tres
Studs at 600mm Max Centres
300m
m M
ax
Nails at 150mm Max Centres
Figure 13 CFS Timber FramedConstruction Fire ResistantPlasterboard Double Layer InstallationFirst Layer and Second Layer Horizontal
Page 2
BGC PlasterboardBefore commissioning a Plasterboard plant in Australia, BGC researched the world's foremost plasterboard
manufacturing countries, in order to adopt the most advanced production techniques, available today.
BGC Plasterboard is purpose designed as a complete wall and ceiling lining system that conforms to the stringentdemands of regulatory bodies throughout Australia and overseas.
Our highly professional team of engineers and skilled personnel maintain world class plant and equipment at ourWestern Australian factory premises and, together with the Company's pursuance of manufacturing excellence,
assures the specifying and building industry of quality BGC Plasterboard products.
As a wholly owned, privately operated Australian company, BGC recognises the importance of product Research andDevelopment programmes. Continued investment into this discipline ensures BGC will remain a leader in the
manufacturing and supply of quality building products and materials.
Page 3
ContentsIntroduction 3
Early Fire Hazard Indices 3
Availability 3
Application 3
Installation 4
Fire-Rated Wall Cold-Formed-Section Steel FramedConstruction-Non Load Bearing 5
Fire-Rated Wall Timber Framed Construction-Non Load Bearing 6
Plasterboard and Fibre Cement Fire and Acoustic Rated Walls 8
Penetrations 11
Steel Frame Installation Details 12
Timber Frame Installation Details 14
BGC Fire-Resistant (FR)Plasterboard Partition Systems
IntroductionBGC Plasterboards Fire-Rated Systems, consist ofsingle or multiple layers of BGC FR Plasterboardsheets, screw-fixed to steel framing and nail or screwfixed to timber stud framing.
BGC FR Plasterboard is manufactured to therequirements of Australian Standards AS/NZS2588:1998 - “Gypsum plasterboard” and must beinstalled in accordance with the Australian StandardsAS/NZS 2589.1:1997 - “Gypsum linings in residentialand light commercial construction-application andfinishing. Part 1: Gypsum plasterboard”.
BGC FR Plasterboard Fire Rated Systems have beentested AS/NZS 3837: 1998 and AS/NZS 1530.4:1997, by NATA accredited testing laboratories.
Test reports and letters of opinion are available onrequest from BGC Plasterboard.
BGC FR Plasterboard has a light-pink facing paper-board for easy identification and is available in 13mmand 16mm thicknesses with recessed edges, ready fortaping and jointing with proprietary stopping andsetting compounds.
Early Fire Hazard IndicesBGC FR Plasterboard complies with the Building Codeof Australia (BCA) Material Group NumberClassification and Deemed to Satisfy Provisions, asdetermined by AS/NZS 3837: 1998 tests.
l Material Classification: Group 1. (BCA) Specification A2.4)
l Suitability as Wall and Ceiling Lining In Fire-Isolated Exits, Public Corridors, Specified and Other Areas. (BCA Specification C1.10a Section 3(c) and Table 2: Wall and Ceiling Linings Material Groups Permitted.
CSIRO BCE Certificate No 482
AvailabilityBGC FR Plasterboard is available in 13mm and 16mmthicknesses, 1200mm wide and in various lengths.
BGC Plasterboard ensures that the range of stocksheet sizes listed, are available however, variations mayoccur in some states, Refer Table 1.
Table 1
ApplicationBGC FR Plasterboard wall systems are suitable forindustrial, commercial and residential applications,both in the new construction and renovation sectors.
Load bearing and non-load bearing walls and partitionscan be clad with single or multiple layers of BGC FRPlasterboard, with or without cavity infill insulation, toachieve the required results for fire resistance: FRLand acoustic properties: RW.
Non-Load Bearing WallsThe maximum wall heights for non-load bearing firerated walls, in this Installation Guide are for laterallyloaded walls of 0.25 kPa, as set out in Tables 2 and 3.
The maximum stud height is based H/240 or 30mmmaximum deflection, to comply with BCA 2004Specification 1.8 Clause 3.4.
Widthmm
1200
1200
Thicknessmm
13mm
16mm
Mass kg/m2
10.2
12.4
Lengths mm
2400
4
4
2700 3000
4
4
3600
4
4
Page 14
Figure 11 Fire CFS Timber Framed Construction Fire ResistantPlasterboard Single Layer Horizontal Installation
Figure 12 CFSTimber Framed ConstructionFire Resistant Plasterboard Double LayerHorizontal Installation
BGC 16mm FireResistant Plasterboard
Fixed One (1) LayerIn Staggered Lay-out
to Each Face of Frame
75 x 45 Top Plate
Caulk Perimeter with Fire-Rated Mastic Nog
ging
at
1350
mm
Max
. Cen
tres
Studs at 600mm Max Centres
Nails at 150mm Max Centres
Set Joints
Nails at Max150 mm Centres
300mmMax
2N
ails
50m
map
part
or 1
Scr
ew
BGC 16mm FireResistant Plasterboard
Fixed Two (2) LayersIn Staggered Lay-out
to Each Face of Frame
75 x 45 Top Plate
Caulk Perimeter with Fire-Rated Mastic
Nog
ging
at
1350
mm
Max
. Cen
tres
Studs at 600mm Max Centres
300m
m M
ax
2 N
ails
50m
map
part
or 1
Scr
ew
Nails at 150mm Max Centres
Fixing Specifications
Fastener Spacing Location
2 Nails 50mm apart at300mm max. centres
1 screw at 200mmmax. centres
Centre of the Board
At Each Stud Recessed Edges
Nails at 150mm max.centres
Screws at 200mmmax. centres
Butt Joints
Nails at 150mm max.centres
Screws at 200mmmax. centres
Corners & Openings
Fixing Specifications
First Layer
Fastener Spacing Location
Nails or Screws600mm max. centres
Centre of the Board
Nails or Screws600mm max. centres
Recessed Edges
Nails or Screws600mm max. centresin staggered pattern
Fastener Spacing Location
2 Nails 50mm apart at300mm max. centres
1 screw at 200mmmax. centres
At Each Stud
Nails at 150mm max.centres
Screws at 200mmmax. centres
Nails at 150mm max.centres
Screws at 300mmmax. centres
Centre of the Board
Recessed Edges
Butt Joints
Corners & Openings
Second Layer
Butt Joints
Timber Frame Installation DetailsThe installation details shown in figures 11 to 13 are suitable for single, double and staggered stud wall configurations.
Page 13
Figure 9 CFS Steel Framed ConstructionFire Resistant Plasterboard Double LayerHorizontal Installation
BGC 16mm FireResistant Plasterboard
Fixed One (1) LayersIn Staggered Lay-out
to Each Face of Frame
Caulk Perimeter with Fire-Rated Mastic Nog
ging
at
1350
mm
Max
. Cen
tres
Studs at 600mm Max Centres
Set Joints
Screws Fixings atMax 300 mm Centres
Screws Fixings Staggardat Max 200 mm Centres
75 x 45 Top Plate
BGC 16mm FireResistant Plasterboard
Fixed One (1) LayersIn Staggered Lay-out
to Each Face of Frame
Caulk Perimeter with Fire-Rated Mastic
Nog
ging
at
1350
mm
Max
. Cen
tres
Studs at 600mm Max Centres
Set Joints
Screws Fixings atMax 300 mm Centres
75 x 45 Top Plate
Fixing Specifications
First Layer
Fastener Spacing Location
600mm max. centres Centre of the Board
At Each Stud Recessed Edges
300mm max. centres Butt Joints
600mm max. centres Corners & Openings
Second Layer
300mm max. centres Centre of the Board
At Each Stud Recessed Edges
200mm max. centres Butt Joints
600mm max. centres Corners & Openings
Fixing Specifications
First Layer
Fastener Spacing Location
600mm max. centres Centre of the Board
600mm max. centres Recessed Edges
600mm max. centres Corners & Openings
Second Layer
300mm max. centres Centre of the Board
At Each Stud Recessed Edges
200mm max. centres Butt Joints
300mm max. centres Corners & Openings
Figure 10 CFS Steel FramedConstruction Fire ResistantPlasterboard Double Layer Vertical &Second Layer Horizontal Installation
Page 4
Steel Stud Wall HeightSteel stud walls above 4.2 m in height must have asingle row of noggings, at the mid-height of the wall.
Table 2 - Non-Load Bearing Steel Stud WallHeight Selection Table
Timber Stud Wall HeightNoggins in timber stud walls must be spaced at 1350mm maximum centres.
Table 3 - Non-Load Bearing Timber StudWall Height Selection Table
Load Bearing WallsLoad bearing walls in this Installation Guide must bedesigned and constructed in accordance with AS 1684and AS 1720, for timber construction and AS/NZS4600 and AS 3623 for light-weight Cold-Formed-Formed (CFS) steel construction.
Load bearing walls must be designed and constructedto take all loads without any cladding or lining.
InstallationInstallation is to be in accordance with the BGCPlasterboard Fixing Instruction Manual: BGC PB201DEC 2003 and as set out in this manual.
Fire rated plasterboard must be fastener fixed to steeland timber framing.
Stud adhesive must not be used.
For double-layered systems all joints must bestaggered and butt joints in the outer layer may bereinforced with laminating screws.
All perimeter gaps and penetrations must be fullysealed with fire rated mastic sealant, to attain therequired FRL and RW ratings.
Table 4 - Screw Fixings for Soft WoodTimber and Lighweight Steel Framing
64 mm
76 mm
92 mm
150 mm
0.50 mm
0.75 mm
1.15 mm
0.50 mm
0.75 mm
1.15 mm
0.50 mm
0.75 mm
1.15 mm
0.75 mm
1.15 mm
Stud Gauge
BMT mm
Plasterboard Thickness mm
13 mm 16 mm
Max Wall Height m
Stud Depth
mm
3.74 m
4.16 m
4.40 m
4.16 m
5.03 m
5.23 m
4.98 m
5.52 m
5.76 m
7.01 m
7.60 m
3.78 m
4.53 m
4.32 m
4.32 m
5.26 m
5.26 m
5.21 m
5.73 m
5.94 m
7.20 m
7.80 m
70 mm
90 mm
120 mm
F5
F8
F11
F5
F8
F11
F5
F8
F11
Timber
Grade
Stud
Thickness
mm
35 mm45 mm35 mm45 mm35 mm45 mm35 mm45 mm35 mm45 mm35 mm45 mm35 mm45 mm35 mm45 mm35 mm45 mm
Stud Spacing mm
600 mm 450 mm
Max Wall Height m
Stud
Depth
mm
3.13.43.43.73.63.94.04.44.44.84.64.85.45.85.96.06.06.0
3.43.73.84.13.94.34.44.84.95.25.15.45.85.96.06.06.06.0
Soft
Wood
Timber
Lightweight
Steel up to
0.8 mm
Thick
Lightweight
Steel From
0.9 mm to
1.2 mm
Thick
13 mm
16 mm
13 mm
16 mm
13 mm
16 mm
40 mm
50 mm
25 mm
4
4
4
FR Board
Thickness
Screw
Type
No. 6Type ‘W’
4
No. 6Type ‘S’Needle Point
4
No. 6Type ‘S’
Drill Point
4
Screw Length (6-18 x mm)
First
Layer
40 mm
65 mm
45 mm
4
4
4
Second
Layer
65 mm
4
Third
Layer
Framing
Page 5
Fire-Rated Wall Cold-Formed-Section Steel Framed Construction - Non Load BearingTable 5
BGC 001
TechnicalOpinionCSIRO
FCO 2356
FRL-/60/60 Stud Depth
mm
647692
150
90102118176
22.122.222.424.0
37373841
44454648
44**454649
44**454648
44454649
42.542.642.844.4
46474749
54555657
54**555657
54**555557
54555657
26.526.626.828.4
38394042
46474850
46**474850
46**474849
46474850
Wall Depthmm
Wall Masskg/m2 Nil 50mm Fibreglass
24 kg/m375mm Fibreglass
14 - 18 kg/m375mm Polyester
8 - 10 kg/m3
Rw
Cavity Infill
One layer 13mm BGC Fire-Rated Plasterboard.
Fixed horizontally or vertically, to CFS steel stud wallframing with noggings.
50mm ‘Rockwool’60 kg/m3
BGC 002
TechnicalOpinionCSIRO
FCO 2356
FRL-/90/90 Stud Depth
mm
647692
150
116128144202
Wall Depthmm
Wall Masskg/m2 Nil 50mm Fibreglass
24 kg/m375mm Fibreglass
14 - 18 kg/m375mm Polyester
8 - 10 kg/m3
Rw
Cavity Infill
Two layers 13mm BGC Fire-Rated Plasterboard.
First layer fixed vertically, and second layer fixedhorizontally or vertically to CFS steel stud wall framing
with noggings.
50mm ‘Rockwool’60 kg/m3
BGC 003
TechnicalOpinionCSIRO
FCO 2356
FRL-/60/60 Stud Depth
mm
647692
150
96108124182
Wall Depthmm
Wall Masskg/m2 Nil 50mm Fibreglass
24 kg/m375mm Fibreglass
14 - 18 kg/m375mm Polyester
8 - 10 kg/m3
Rw
Cavity Infill
One layer 16mm BGC Fire-Rated Plasterboard.
Fixed horizontally or vertically, to CFS steel stud wallframing with noggings.
50mm ‘Rockwool’60 kg/m3
Page 12
Steel Frame Installation DetailsThe installation details shown in figures 7 to 10 are suitable for single, double and staggered stud wall configurations.
Figure 7 Fire CFS Steel FramedConstruction Fire ResistantPlasterboard Single LayerHorizontal Installation
Figure 8 CFS Steel FramedConstruction Fire ResistantPlasterboard Single LayerVertical Installation
BGC 16mmFire Resistant
PlasterboardFixed One (1) Layers
In StaggeredLay-out to Each
Face of Frame
75 x 45 Top Plate
Caulk Perimeter with Fire-Rated Mastic
Nog
ging
at
1350
mm
Max
. Cen
tres
Studs at 600mm Max Centres
Screws at 300mm Max centres
Set Joints
Scre
ws F
ixing
s at
Max
300
mm
Cen
tres
Scre
ws F
ixing
s St
agga
rd a
tM
ax 2
00 m
m C
entr
es
Scre
ws F
ixing
s at
Max
300
mm
Cen
tres
75 x 45 Top Plate
BGC 16mm FireResistant Plasterboard
Fixed One (1) LayerIn Staggered Lay-out
to Each Face of Frame
Nog
ging
at
1350
mm
Max
.Cen
tres
Studs at 600mm Max Centres
Do Not Fix to Topor Bottom Track
(non load bearing)
Maintain 6mmGapBetween Sheet and Floor
Caulk Perimeter withFire-Rated Mastic
Stag
gerF
ixing
s at
Max
300
mm
cent
res
Note: All Joints Must
be Backed by Studs
Screw Fixings atMax 300 mm Centres
Fixing Specifications
Fastener Spacing Position
300mm max. centres Centre of the Board
At each stud Recessed Edges
200mm max. centres Butt Joints
300mm max. centres Corners & Openings
Fixing Specifications
Fastener Spacing Position
300mm max. centres Centre of the Board
300mm max. centres Recessed Edges
200mm max. centres Butt Joints
300mm max. centres Corners & Openings
Page 11
Penetrations (Typical)Special design considerations apply to Fire Rated wallsin order to maintain the Fire Rating (FRL) of a system.
l Electrical penetrations must not be placed back to back or more than one penetration per stud spacing.
l Proprietery Fire Rated switch boxes are to be used.
l BGC Plasterboard recommends the use of min R1.5 insulation batt be included in the wall cavity to assistin maintaining acoustic integrity.
l All penetrations shall be sealed with a Fire Rated mastic filler. See Figure 1.
l Where plumbing penetrations are required - all pipework must be self supporting.
Figure 6 - Electrical Penetration ThroughWall (Typical)Note: Do not place switch boxes back to back.
Figure 1 - Pipe Penetration Through Wall(Copper)
BGC FRPlasterboard
Proprietery firerated switch box
installed tomanufacturers
recommendations
Fire rated mastic
Fire rated mastic
20mm
Fire ratedmastic fillerBacking rod
(not fire rated)
BGC FRPlasterboard
Pipework(152mmmax diam)
Figure 2 - Pipe Penetration Through Ceiling
Figure 3 - Control Joint - Wall Frame Double Layer
Wire meshflame guard
Fire rated mastic filler
15mm Min
100mm Max(copper) pipe
BGC FR Plasterboard
6mm
I.B.S. Fyreguardfoam 50 x 20
Backing rod
Additional studrequired at control joint
Rondo P53control joint
typical
BGC FR Plasterboard
20 mm min
15 mmFire rated masticMin depth 15mm
Top andbottom track isdiscontinuous
Figure 5 - Control Joint - Wall Frame
BGC Fibre Cement sheeting
Backing rod
Additional studrequired at control joint
BGC FR Plasterboard
10 mmFire rated masticMin depth 15mm
Top andbottom track isdiscontinuous
Figure 4 - Control Joint - Wall Frame Single Layer
Backing rod
BGC FR Plasterboard
15 mm min
Additional studrequired at control joint
Rondo P53control joint
typical
15 mmFire rated masticMin depth 15mm
Top andbottom track isdiscontinuous
Page 6
BGC 004
TechnicalOpinionCSIRO
FCO 2356
FRL-/120/120 Stud Depth
mm
647692
150
128140156214
Wall Depthmm
Wall Masskg/m2 Nil 50mm Fibreglass
24 kg/m375mm Fibreglass
14 - 18 kg/m375mm Polyester
8 - 10 kg/m3
Rw
Cavity Infill
Two layers 16mm BGC Fire-Rated Plasterboard.
First layer fixed vertically, and second layer fixedhorizontally or vertically to CFS steel stud wall framing
with noggings.
50mm ‘Rockwool’60 kg/m3
Fire-Rated Wall Timber Framed Construction - Non Load BearingTable 6
BGC 005
TechnicalOpinionCSIRO
FCO 2356
FRL-/60/60 Stud Depth
mm
7090
120140
96116146166
Wall Depthmm
Wall Masskg/m2 Nil 50mm Fibreglass
24 kg/m375mm Fibreglass
14 - 18 kg/m375mm Polyester
8 - 10 kg/m3
Rw
Cavity Infill
One layer 13mm BGC Fire-Rated Plasterboard.
Fixed horizontally or vertically, to CFS timber stud wallframing with noggings.
50mm ‘Rockwool’60 kg/m3
BGC 006
TechnicalOpinionCSIRO
FCO 2356
FRL-/90/90 Stud Depth
mm
7090
120140
122142172192
51.351.451.653.2
24.224.825.726.3
36373838
40414142
40**414142
40**414141
41414142
48484951
56565657
56**565757
55**565657
56565757
44.645.246.146.7
44454546
48484849
48**484849
48**484849
48484849
Wall Depthmm
Wall Masskg/m2 Nil 50mm Fibreglass
24 kg/m375mm Fibreglass
14 - 18 kg/m375mm Polyester
8 - 10 kg/m3
Rw
Cavity Infill
Two layers 13mm BGC Fire-Rated Plasterboard.
First layer fixed vertically, and second layer fixedhorizontally or vertically to CFS timber stud wall
with noggings.
50mm ‘Rockwool’60 kg/m3
Page 7
BGC 007
TechnicalOpinionCSIRO
FCO 2356
FRL-/60/60 Stud Depth
mm
7090
120140
102122152172
Wall Depthmm
Wall Masskg/m2 Nil 50mm Fibreglass
24 kg/m375mm Fibreglass
14 - 18 kg/m375mm Polyester
8 - 10 kg/m3
Rw
Cavity Infill
One layer 16mm BGC Fire-Rated Plasterboard.
Fixed horizontally or vertically, to CFS timber stud wallframing with noggings.
50mm ‘Rockwool’60 kg/m3
BGC 008
TechnicalOpinionCSIRO
FCO 2356
FRL-/120/120 Stud Depth
mm
7090
120140
134154184204
53.454.054.955.5
45464647
48484848
48**484849
48**484849
48484950
28.629.230.130.7
37383940
41414242
41**414243
41**414142
41414243
Wall Depthmm
Wall Masskg/m2 Nil 50mm Fibreglass
24 kg/m375mm Fibreglass
14 - 18 kg/m375mm Polyester
8 - 10 kg/m3
Rw
Cavity Infill
Two layers 16mm BGC Fire-Rated Plasterboard.
First layer fixed vertically, and second layer fixedhorizontally or vertically to CFS Timber stud wall
framing with noggings.
50mm ‘Rockwool’60 kg/m3
Note: RW figures marked thus; ** have 50mm insulation.
Page 10
One layer 7.5mm BGC Duratex™ sheets fixed over alayer of 16mm BGC FR Plasterboard fixed to the
outside of the timber-framed stud wall with noggings.
One layer 6mm BGC Duraliner™ sheets fixed over alayer of 16mm BGC FR Plasterboard fixed to the
inside of the timber-framed stud wall.
One layer 7.5mm BGC Duratex™ sheets fixed over alayer of 16mm BGC FR Plasterboard fixed to theoutside of the timber stud wall with noggings.
One layer 6mm BGC Duraliner™ sheets fixed over alayer of 16mm BGC FR Plasterboard fixed to the
inside of the timber stud wall.
One layer 7.5mm BGC Duratex™ sheets fixed over alayer of 13mm BGC FR Plasterboard fixed over fire-resistant building paper to the outside of the timber-
framed stud wall with noggings.
One layer 6mm BGC Duraliner™ sheets fixed over alayer of 13mm BGC FR Plasterboard fixed to the
inside of the timber stud wall.
6mm BGC Duraliner
16mm BGC FRPlasterboard
600mm max centres 7.5mmBGC DuratexBGC DT001
60/60/60
Branz TestNo. FR 2924
UDL of 9 kNper stud
Stud Depthmm
90 135.5 49.5 46* 54 55 5654
Wall Depthmm
Wall Masskg/m2 Nil 50mm Fibreglass
12 kg/m375mm Fibreglass
14 - 18 kg/m375mm Polyester
12 kg/m3
Rw
Cavity Infill
50mm ‘Rockwool’60 kg/m3
6mm BGC Duraliner
16mm BGC FRPlasterboard
600mm max centres 7.5mmBGC DuratexBGC DT002
-/90/90
Branz TestNo. FR 2924
Non-LoadBearing
Stud Depthmm
90 135.5 49.5 46* 54 55 5654
Wall Depthmm
Wall Masskg/m2 Nil 50mm Fibreglass
12 kg/m375mm Fibreglass
14 - 18 kg/m375mm Polyester
12 kg/m3
Rw
Cavity Infill
50mm ‘Rockwool’60 kg/m3
6mm BGC Duraliner
600mm max centres
7.5mmBGC Duratex
13mm BGC FRPlasterboard
Fire-Resistantbuilding paper to outer leaf
BGC DT00390/90/90
Branz Opinion
FAR 1764
UDL of 6 kNper stud
Stud Depthmm
90 129.5 45.1 45 45* 49 48 49
Wall Depthmm
Wall Masskg/m2 Nil 50mm Fibreglass
12 kg/m375mm Fibreglass
14 - 18 kg/m375mm Polyester
12 kg/m3
Rw
Cavity Infill
50mm ‘Rockwool’60 kg/m3
*The Rw values for the Duratex™ are opinions based on tests conducted by Acoustic Laboratories Australia.
Page 9Page 8
One layer 16mm BGC FR Plasterboard sheets fixedover a layer of 6mm BGC Duraliner™ fixed to
timber-framed wall with noggings.
One layer 13mm BGC FR Plasterboard sheets fixedover a layer of 6mm BGC Duraliner™ fixed to
timber-framed staggered stud wall with noggings.
One layer 6mm BGC Duraliner™ sheets fixed over alayer of 13mm BGC FR Plasterboard fixed to
timber-framed staggered stud wall with noggings.
6mm BGCDuraliner
16mm BGCFR Plasterboard
600mm max centres
BGC DL00490/90/90
BRANZTest No.
FR 2754-1
Stud Depthmm
90 134 47 50 48
Wall Depthmm
Wall Masskg/m2 Nil 50mm Fibreglass
12 kg/m375mm Fibreglass
14 - 18 kg/m375mm Polyester
12 kg/m3
Rw
Cavity Infill
50mm ‘Rockwool’60 kg/m3
6mm BGC Duraliner
13mm BGC FRPlasterboard
300mm max centres
BGC DL00560/60/60
BRANZOPINION No.FAR 1542-1
Stud Depthmm
70 108 50 57* 55
Wall Depthmm
Wall Masskg/m2 Nil 50mm Fibreglass
12 kg/m375mm Fibreglass
14 - 18 kg/m375mm Polyester
12 kg/m3
Rw
Cavity Infill
50mm ‘Rockwool’60 kg/m3
6mm BGCDuraliner
13mm BGC FR Plasterboard
300mm max centres
BGC DL00660/60/60
BRANZOPINION No.FAR 1542-1
Stud Depthmm
90 128
48.9
45.1
46.0 48 57
50
57
57 54
48
54
54
Wall Depthmm
Wall Masskg/m2 Nil 50mm Fibreglass
12 kg/m375mm Fibreglass
14 - 18 kg/m375mm Polyester
12 kg/m3
Rw
Cavity Infill
50mm ‘Rockwool’60 kg/m3
*The Rw values for the Duratex™ are opinions based on tests conducted by Acoustic Laboratories Australia.
Plasterboard and Fibre Cement Fire and Acoustic Rated Internal WallsBGC Plasterboard in conjunction with BGC Fibre Cement has Duraliner™ and Duratex™ sheets which are suitable for
external and internal wall applications if fire and acoustic ratings are required.
The Rw Values are opinions based on tests conducted by Acoustic Laboratories Australia and computer predictedvalues using the Marshall Day Acoustics program.
*Denotes actual test carried out by ALA (Acoustic Laboratories Australia) Pty Ltd.
Table 7 - Single and Staggered Stud Construction
9mm BGC Duraliner
16mm BGC FRPlasterboard
6mm BGC Duraliner
13mm BGC FRPlasterboard
600mm max centres
6mm BGCDuraliner
13mm BGC FRPlasterboard
600mm max centres
BGC DL001120/120/120
BRANZTest No.
FR 2755-1Stud Depth
mm
64
76
92
114
126
142
48
48
49
52*
56
58
52**
57
58
56**
57
58
57
57
58
Wall Depthmm
Wall Masskg/m2 Nil 50mm Fibreglass
12 kg/m375mm Fibreglass
14 - 18 kg/m375mm Polyester
12 kg/m3
Rw
Cavity Infill
One layer 16mm BGC Fire-Rated Plasterboard fixedhorizontally or vertically over a layer of 9mm
Duraliner™ fibre cement sheets, fixed horizontally toCFS steel stud wall framing with noggings.
50mm ‘Rockwool’60 kg/m3
BGC DL00260/60/60
BRANZTest No.
FR 2752-1
Stud Depthmm
90 128 46 51 51 50 48
Wall Depthmm
Wall Masskg/m2 Nil 50mm Fibreglass
12 kg/m375mm Fibreglass
14 - 18 kg/m375mm Polyester
12 kg/m3
Rw
Cavity Infill
One layer 6mm BGC Duraliner™ fixed horizontallyover a layer of 13mm BGC Fire Rated Plasterboardsheets, fixed to timber framed wall with noggings.
50mm ‘Rockwool’60 kg/m3
BGC DL00360/60/60
BRANZTest No.
FR 2753-1
Stud Depthmm
90 128
45.5
45.6
45.8
43.8
43.8 46 51 50 50 49
Wall Depthmm
Wall Masskg/m2 Nil 50mm Fibreglass
12 kg/m375mm Fibreglass
14 - 18 kg/m375mm Polyester
12 kg/m3
Rw
Cavity Infill
One layer 13mm BGC Fire-Rated Plasterboard sheetsfixed over a layer of 6mm BGC Duraliner™ fixed to
timber-framed wall with noggings.
50mm ‘Rockwool’60 kg/m3