Follow-Me charge stage coordination and what to expect out of multiple charge controllers.

16
Follow-Me charge stage coordination and what to expect out of multiple charge controllers. [email protected]

description

Follow-Me charge stage coordination and what to expect out of multiple charge controllers. [email protected]. Ryan, Technical Support Manager [email protected] 360-403-7207 XT151. [email protected]. - PowerPoint PPT Presentation

Transcript of Follow-Me charge stage coordination and what to expect out of multiple charge controllers.

Page 1: Follow-Me charge stage coordination and what to expect out of multiple charge controllers.

Follow-Me charge stage coordination and what to expect

out of multiple charge [email protected]

Page 2: Follow-Me charge stage coordination and what to expect out of multiple charge controllers.

Ryan, Technical Support [email protected]

360-403-7207 XT151

[email protected]

Page 3: Follow-Me charge stage coordination and what to expect out of multiple charge controllers.

*Multiple Charge controllers without Follow-Me*Multiple Charge controllers with Follow-Me*Follow-Me

[email protected]

Page 4: Follow-Me charge stage coordination and what to expect out of multiple charge controllers.

*Controllers each need a Battery temp sensor*Equalize needs to be started on each controller*Float charges not coordinated *Displays needed for each controller

[email protected]

Page 5: Follow-Me charge stage coordination and what to expect out of multiple charge controllers.

*1 battery temp sensor needed*EQ, manual or Auto can be controlled by a single controller*Going to Float is coordinated*Single display can view all Follow-Me Classic’s

[email protected]

Page 6: Follow-Me charge stage coordination and what to expect out of multiple charge controllers.
Page 7: Follow-Me charge stage coordination and what to expect out of multiple charge controllers.

Programming Follow-Me

[email protected]

Press “Main Menu” and then use the arrows to scroll to “Tweaks” and press “Enter”

Page 8: Follow-Me charge stage coordination and what to expect out of multiple charge controllers.

Programming Follow-Me

[email protected]

Press the button labeled “More” and Press it again for “More2”

Page 9: Follow-Me charge stage coordination and what to expect out of multiple charge controllers.

Programming Follow-Me

[email protected]

Press the button labeled “More3” and Press it again for “More4”

Page 10: Follow-Me charge stage coordination and what to expect out of multiple charge controllers.

Programming Follow-Me

[email protected]

*Set the number for FollowMe*Turn BTS-NET on if wanted*Enter to save*Status button to return to “Home” screen

Page 11: Follow-Me charge stage coordination and what to expect out of multiple charge controllers.

Ground fault sharing

*Enable ground fault Hardware and software on one Classic only*Enable ground fault Software on any additional Classic’s you wish to turn off on GF

[email protected]

Page 12: Follow-Me charge stage coordination and what to expect out of multiple charge controllers.

Naming the Classic

*Use the Local App to name the Classic*Name shows up on the display of each Classic making navigating multiple Classic’s easier

[email protected]

Page 13: Follow-Me charge stage coordination and what to expect out of multiple charge controllers.

Addressing each Classic for viewing on a single MNGP

*Hold Left arrow and tap up or down to change address*Find an unused address to address that Classic to and press and hold left and right arrow till saved (Classic is address 10 by default)*Use the MNGP to address any Lite’s*Hold left arrow and tap up or down arrow to view different Classics on the Follow-Me network

[email protected]

Page 14: Follow-Me charge stage coordination and what to expect out of multiple charge controllers.

Programming the Classic Lite for Follow-Me

*Use the standard Classic’s MNGP and physically plug it into each Lite and follow the steps from earlier to enable Follow-Me, Battery temp sharing and Addressing of the Lite (If wanted)*Set the MNLP to Custom and plug it in. *MNLP’s from serial # 5435 or older will not work with Follow-Me, either leave them unplugged or contact us for a replacement

[email protected]

Page 15: Follow-Me charge stage coordination and what to expect out of multiple charge controllers.

*Absorb time and voltage must be set on all*Float voltage must be set on all*EQ time and voltage must be set on all*LED1 mode gives visual indication of function*Wind Synch*Cloned settings

[email protected]

Page 16: Follow-Me charge stage coordination and what to expect out of multiple charge controllers.

[email protected]

Questions?

Ryan StankevitzMidNite Solar360-403-7207 XT [email protected]