Folder Comercial_English - AMBAR. Adhesive System for Enamel and Dentin

12
Adhesive System for Enamel and Dentin

description

Ambar FGM is a two-step conventional adhesive system (5th generation), which formula was developed to assure the adequate penetration of the monomers into the collagen fibers of demineralized dentin. Depois de polimerizado, After polymerization, Ambar generates a stable and resistant adhesive film, contributing to its clinical longevity. The presence of nanoparticles in the composition contributes to the increase of the mechanical resistance and chemical stability of the polymerized adhesive film. In addition, the chemical characteristics of Ambar warrant adequate polymerization of the product on wet surfaces, such as dentin. AMBAR GATHERS ALL QUALITIES OF A DIFFERENTIATED ADHESIVE.

Transcript of Folder Comercial_English - AMBAR. Adhesive System for Enamel and Dentin

Page 1: Folder Comercial_English - AMBAR. Adhesive System for Enamel and Dentin

Adhesive System for Enamel and Dentin

Page 2: Folder Comercial_English - AMBAR. Adhesive System for Enamel and Dentin

A m b a r, s i n c e a n c i e n t t i m e s , h a s b e w i t c h e d a n d c o n t i n u e s

t o b e w i t c h p e o p l e l i k e a r a r e j e w e l . I n n a t u r e , a m b a r i s a

f o s s i l i z e d t r e e r e s i n . Tr e e s t h a t p r o d u c e d a m b a r l i v e d m i l l i o n s

o f y e a r s a g o . T h e r e s i n t h a t t h e s e t r e e s p r o d u c e d w o r k e d a s

p r o t e c t i o n a g a i n s t b a c t e r i a a n d a g a i n s t b u g s t h a t p e r f o r a t e d

t h e i r w o o d . A s t i m e w e n t b y, t h i s r e s i n s t a r t e d t o l o s e w a t e r

a n d a i r, a n d t h e o r g a n i c s u b s t a n c e s t h a t c o n s t i t u t e d i t w e n t

t h r o u g h w h a t c h e m i s t s c a l l p o l y m e r i z a t i o n . R e s i n h a r d e n e d

a n d c h a n g e d i n t o w h a t w e k n o w a s a m b a r.

A M B A R I S T H E B E S T E X A M P L E O F T H E S TA B I L I T Y

A N D L O N G E V I T Y O F A P O LY M E R .

Page 3: Folder Comercial_English - AMBAR. Adhesive System for Enamel and Dentin

Ambar FGM is a two-step conventional adhesive system (5th

generation), which formula was developed to assure the adequate

penetration of the monomers into the collagen fibers of demineralized

dentin. Depois de polimerizado, After polymerization, Ambar generates

a stable and resistant adhesive film, contributing to its clinical longevity.

The presence of nanoparticles in the composition contributes to the

increase of the mechanical resistance and chemical stability of the

polymerized adhesive film. In addition, the chemical characteristics of

Ambar warrant adequate polymerization of the product on wet surfaces,

such as dentin.

AMBAR GATHERS ALL QUALITIES OF A DIFFERENTIATED ADHESIVE.

Page 4: Folder Comercial_English - AMBAR. Adhesive System for Enamel and Dentin

INDICATIONS

PRESENTATION

• All classes of direct restorations with composites (class I, II, III, IV and V).

• Adhesive cementation (jointly with resin cements) of prosthetic pieces (intracanal pins/

cores, crowns, onlays/inlays, veneers, etc.) in fiberglass, ceromer, ceramics, resin and

metal.

• Adhesive repairs in ceramics and composites.

AMBAR. THE ADHESIVE FOR ALL CLINICAL APPLICATIONS.

Flask containing 6 ml of product with instructions to the professionals.

Dosing tip that prevents waste.Dosing tip that prevents waste.

Page 5: Folder Comercial_English - AMBAR. Adhesive System for Enamel and Dentin

IMMEDIATE AND AFTER AGING BOND STRENGTHIMMEDIATE AND AFTER AGING BOND STRENGTHIMMEDIATE AND AFTER AGING BOND STRENGTHIMMEDIATE AND AFTER AGING BOND STRENGTHIMMEDIATE AND AFTER AGING BOND STRENGTHIMMEDIATE AND AFTER AGING BOND STRENGTHIMMEDIATE AND AFTER AGING BOND STRENGTHIMMEDIATE AND AFTER AGING BOND STRENGTHIMMEDIATE AND AFTER AGING BOND STRENGTHIMMEDIATE AND AFTER AGING BOND STRENGTHIMMEDIATE AND AFTER AGING BOND STRENGTHIMMEDIATE AND AFTER AGING BOND STRENGTHIMMEDIATE AND AFTER AGING BOND STRENGTHIMMEDIATE AND AFTER AGING BOND STRENGTHIMMEDIATE AND AFTER AGING IMMEDIATE AND AFTER AGING IMMEDIATE AND AFTER AGING IMMEDIATE AND AFTER AGING IMMEDIATE AND AFTER AGING BOND STRENGTHIMMEDIATE AND AFTER AGING BOND STRENGTHIMMEDIATE AND AFTER AGING BOND STRENGTHIMMEDIATE AND AFTER AGING BOND STRENGTHIMMEDIATE AND AFTER AGING BOND STRENGTHIMMEDIATE AND AFTER AGING BOND STRENGTHIMMEDIATE AND AFTER AGING BOND STRENGTHIMMEDIATE AND AFTER AGING BOND STRENGTHIMMEDIATE AND AFTER AGING BOND STRENGTHIMMEDIATE AND AFTER AGING BOND STRENGTHIMMEDIATE AND AFTER AGING BOND STRENGTHIMMEDIATE AND AFTER AGING BOND STRENGTHIMMEDIATE AND AFTER AGING BOND STRENGTHIMMEDIATE AND AFTER AGING BOND STRENGTHIMMEDIATE AND AFTER AGING BOND STRENGTHIMMEDIATE AND AFTER AGING BOND STRENGTHIMMEDIATE AND AFTER AGING BOND STRENGTH

AMBAR, SAFETY AND LONGEVITY FOR YOUR RESTORATIONS.

HIGH BOND STRENGTH.Comparable to the best adhesive

systems on the market.

EFFECTIVE CURE.Even in damp environment, providing

resistance and longevity to the adhesion.

TESTED POST- OPERATORY SENSIBILITY.

Clinical evaluations performed by

several dental surgeons report

absence of post-operatory

sensitivity.

SOLVENT: ETHANOL.It has a composition of balanced

monomers and solvent, conferring

high affinity by the dentin and

perfect formation of hybrid layer.

EASY TO APPLY.Adequate viscosity and clinically

visible adhesive film.

TESTED AND VALIDATEDIN THE LABORATORYAND CLINICALLY.

Contains NANOPARTICLESof silica that confer best sealing

capability and cohesive resistance

to the adhesive film.

Microtensile Bond Strength

(MPA) of different adhesives on

human dentin: immediate data

and after 20,000 thermal cycles.

Courtesy of Dr. Jorge Perdigão,

University of Minnesota – USA,

2009 (averages with the same

letter do not present statistical

difference (p<0.05)).

AMBAR PRESENTS EXCELLENT BOND STRENGTH, immediately and after aging, indicating the stability and longetivity of the adhesion.

GOOD REASONS FOR YOU TO USE AMBAR:

othersImmediate

20.000x thermal cycled

FGMImmediate

20.000x thermal cycled

aa

aa

c

b

Ambar(FGM)

Adper Single Bond 2(3M ESPE)

Excite(Ivoclar - Vivadent)

Bo

nd S

tren

gth

(M

PA

)

0

80

70

60

50

40

30

20

10

Page 6: Folder Comercial_English - AMBAR. Adhesive System for Enamel and Dentin

AMBAR, QUALITY IN NUMBERS AND IMAGES

Note the long tags formed by Ambar, denoting high affinity by the dentin.Courtesy of Dr. Jorge Perdigão,

University of Minnesota – USA.

Note the excellent quality of the hybrid layer, even after challenge by thermocycling (20,000 thermal cycles). Courtesy of Dr. Jorge Perdigão,

University of Minnesota – USA.

Expanded imaged: note the capacity of Ambar to fill even

the anatomosis.Courtesy of Dr. Jorge Perdigão,

University of Minnesota – USA.

Images of MEV on the hybrid layer formed by Ambar on human tooth, before and after

challenge by thermocycling (20,000 cycles, 5 ºC – 55 ºC):

HIGH AFFINITY BY THE DENTINE

STABILITY OF THE HYBRID LAYER

EXCELLENT FILLING

Page 7: Folder Comercial_English - AMBAR. Adhesive System for Enamel and Dentin

AMBAR: CLINICAL SAFETY,NO FEAR OF NANOLEAKAGEAMBAR: CLINICAL SAFETY,NO FEAR OF NANOLEAKAGEAMBAR: CLINICAL SAFETY,NO FEAR OF NANOLEAKAGEAMBAR: CLINICAL SAFETY,NO FEAR OF NANOLEAKAGEAMBAR: CLINICAL SAFETY,NO FEAR OF NANOLEAKAGEAMBAR: CLINICAL SAFETY,NO FEAR OF NANOLEAKAGEAMBAR: CLINICAL SAFETY,NO FEAR OF NANOLEAKAGEAMBAR: CLINICAL SAFETY,NO FEAR OF NANOLEAKAGEAMBAR: CLINICAL SAFETY,NO FEAR OF NANOLEAKAGEAMBAR: CLINICAL SAFETY,NO FEAR OF NANOLEAKAGEAMBAR: CLINICAL SAFETY,NO FEAR OF NANOLEAKAGEAMBAR: CLINICAL SAFETY,NO FEAR OF NANOLEAKAGEAMBAR: CLINICAL SAFETY,NO FEAR OF NANOLEAKAGEAMBAR: CLINICAL SAFETY,AMBAR: CLINICAL SAFETY,AMBAR: CLINICAL SAFETY,AMBAR: CLINICAL SAFETY,NO FEAR OF NANOLEAKAGEAMBAR: CLINICAL SAFETY,NO FEAR OF NANOLEAKAGEAMBAR: CLINICAL SAFETY,NO FEAR OF NANOLEAKAGEAMBAR: CLINICAL SAFETY,NO FEAR OF NANOLEAKAGEAMBAR: CLINICAL SAFETY,NO FEAR OF NANOLEAKAGEAMBAR: CLINICAL SAFETY,NO FEAR OF NANOLEAKAGEAMBAR: CLINICAL SAFETY,NO FEAR OF NANOLEAKAGEAMBAR: CLINICAL SAFETY,NO FEAR OF NANOLEAKAGEAMBAR: CLINICAL SAFETY,NO FEAR OF NANOLEAKAGEAMBAR: CLINICAL SAFETY,NO FEAR OF NANOLEAKAGEAMBAR: CLINICAL SAFETY,NO FEAR OF NANOLEAKAGEAMBAR: CLINICAL SAFETY,NO FEAR OF NANOLEAKAGEAMBAR: CLINICAL SAFETY,NO FEAR OF NANOLEAKAGEAMBAR: CLINICAL SAFETY,NO FEAR OF NANOLEAKAGEAMBAR: CLINICAL SAFETY,NO FEAR OF NANOLEAKAGEAMBAR: CLINICAL SAFETY,NO FEAR OF NANOLEAKAGEAMBAR: CLINICAL SAFETY,NO FEAR OF NANOLEAKAGEAMBAR: CLINICAL SAFETY,NO FEAR OF NANOLEAKAGE

Resin

HybridLayer

HybridDentin

See the absence of nanoin� ltration on the adhesive layer generated by Ambar.Courtesy of Dr. Jorge Perdigão,

University of Minnesota – USA.

Image of Scanning Electron Microscopy

(SEM) of the hybrid layer formed by Ambar

(FGM) on human dentin after thermal

challenge (20,000 cycles 5-55º C).

aa a

b

c

Ambar(FGM)

Adper Single Bond 2

(3M ESPE)

XP - Bond(Dentsply)

Tetric N-Bond

(Ivoclar Vivadent)

Stae(SDI)

Nan

ole

akag

e %

50

45

40

35

30

25

20

15

10

5

0

In a study comparing nanoleakage of the

major adhesive systems, Ambar proved

to be effective and equivalent to the best

systems in the market.

Courtesy of Dr. Alessandro Loguércio,

Dra. Alessandra Reis et al.,

State University of Ponta Grossa/PR - Brazil.

CLINICAL EVALUATION

Image shows the quality of the restoration after 6 months.Courtesy of Dr. Alessandro Loguércio,

Dra. Alessandra Reis, Dra. Letícia Ferri

and Dra. Thays Costa – State University of

Ponta Grossa/PR - Brazil.

Page 8: Folder Comercial_English - AMBAR. Adhesive System for Enamel and Dentin

CONFIRMED EFFECTIVENESS AND CLINICAL SAFETY

Tested post-operatory sensitivity: clinical evaluations of many dental surgeons report absence of post-operatory sensitivity.

SEE AMBAR’S HIGH PERFORMANCE IN CLINICAL EVALUATION:

The balance of the chemical composition of Ambar assures its excellent

polymerization, preventing the release of substances capable of causing post-

operatory sensibility, in addition to the formation of a good adhesive layer, with long

and obliterating tags, minimizing the movement of fluids to the dentin.

of restorations made with

Ambar have kept stable and

WITH NO NEED FOR REPAIR. 2,9% need only

to be polished.

97,1%of the restorations made with Adper Single Bond 2, after 6 months, kept stable and

with no need for repair.

91,4%

Results obtained after 6 months of clinical study conducted by Dr. Alessandro Loguércio, Dra. Alessandra Reis, Dra. Letícia Ferri and Dra. Thays Costa – State University of Ponta Grossa/PR - Brazil, in non-carious cervical lesions. The full study is published in Ambar Technical Profile, available at site www.fgm.ind.br.

d

c

b

a a

Ambar (FGM)

Adper Single Bond 2 (3M ESPE)

XP - Bond (Dentsply)

Tetric N-Bond (Ivoclar Vivadent)Stae (SDI)

Co

hesi

ve S

tren

gth

(M

Pa)

12

10

8

6

4

2

0

Mechanical resistance of different

adhesives in the market.

Courtesy of Dr. Alessandro Loguércio

and Dra. Alessandra Reis, UEPG/PR -

Brazil (different letters indicate statistical

difference (p<0.05)).

With these results, Ambar can be approved by ADA parameters (American Dental

Association).

Page 9: Folder Comercial_English - AMBAR. Adhesive System for Enamel and Dentin

STEP BY STEP

The product is indicated for direct and indirect adhesive restorations (aid in

adhesive cementation) and also in repair of indirect restorations.

Below, a case is presented illustrating the way of application of the adhesive on dental surface

(enamel and dentin). This application should be preceded by the steps required as per each

indication, being that each situation may have a different clinical protocol.

1a - 1b: After cleaned, both

surfaces – of enamel and dentin –

should be conditioned for 15 seconds,

with phosphoric acid (Condac 37).

5 and 6: The adhesive is then

lightcured for 10 seconds (or 20

seconds for intracanal application) by

blue light lightcuring unit with minimum

power density of 400m W/cm2.

Then, restoration may continued or

proceeding with adhesive cementation,

etc., depending on the case.

4: The application of a slight air jet for 10 seconds

helps evaporation of the solvent and contributes

to the adhesion.

2: The acid is removed with plenty of

water and the surface is dried, leaving the

substrate slightly damp. If the surface is too

dry, a dampened cotton ball may be applied

to the tooth.

3: A drop of Ambar (FGM) should be

dispensed in micro application tips Cavibrush

(FGM). The first layer of adhesive is then

applied by rubbing it for 10 seconds. Then, a

second layer is applied for 10 seconds more,

using a new drop of adhesive.

For more information, see technical profile available for download in our site.

In case of questions, check with our technical support: [email protected] or +55 47 3441 6100.

Page 10: Folder Comercial_English - AMBAR. Adhesive System for Enamel and Dentin

THEY HAVE INVESTIGATED

DRA. ALESSANDRA REISDoctor in Dental Materials from the School of Dentistry of the University of São Paulo, SP;

Guiding Professor of the Post-Graduation Course of UEPG/PR/Brazil.

“I have followed the development of Ambar since its

preliminary stages up to the final formulation of the adhesive. I

was impressed by the laboratory and clinical results obtained

with the material, which were similar to the highly reputable

adhesives in the Brazilian and international markets. The

launch of Ambar will be a landmark in the market, showing the

Brazilian companies can formulate products with quality similar

and even above that of international products!”

DR. JORGE PERDIGÃODMD from the University of Lisbon, Portugal; Master in Dentistics (University of Iowa - USA);

Specialization in Dentistics (University of Iowa - USA); Doctor’s in Dental Materials (Catholic

University of Leuven - Belgium); Head Professor of Operatory Dentistics at the University of

Minnesota - USA.

“Ambar has resulted in an effectively filled hybrid layer.”

Page 11: Folder Comercial_English - AMBAR. Adhesive System for Enamel and Dentin

“The development of an adhesive system is always a

challenge to a company, since this situation requires many

efforts and many preliminary studies. In the case of Brazil, this

is an even higher challenge, because the domestic market

lacks good quality products manufactured here. FGM seems

to have again done its “home work”, because the lab and

clinical results with Ambar that we obtained have shown that

this adhesive is really a material of excellent quality and can

be used without any sort of suspicion by Brazilian dentists.”

Specialist and Master in Dentistics (FO-UFPEL); Doctor in Dental Materials (FO-USP/ Brazil);

Professor of Dentistry and Materials (UNOESC/Joaçaba/SC/ Brazil) and Dentistry (UEPG/PR/

Brazil).

DR. ALESSANDRO LOGUÉRCIO

DR. CARLOS EDUARDO FRANCCIGraduated from the School of Dentistry of the University of São Paulo - Brazil (FO-

USP/ Brazil); Master and Doctor in Dental Materials (FO-USP/ Brazil); Coordinator of the

Group Francci de Estudos em Estética; Coordinator of Update Courses in Dentistics at

FUNDECTO.

“Being a clinical and laboratory investigator, I received

Ambar to use in my private practice. Since I have a good

relationship with the researchers that tested Ambar and

know quite well how serious FGM is in looking into a product

exhaustively before launching it, I felt safe in using it clinically.

Immediately I could assess the post-operatory sensitivity,

which was zero in more than three months of usage. Its way

of application is similar to that of the major adhesive systems

of the same family already consecrated in the market. All

these issues warrant a smooth and safe change to the

consumers of the new national adhesive, Ambar.”

Page 12: Folder Comercial_English - AMBAR. Adhesive System for Enamel and Dentin

+55 47 3441 6100 | www.fgm.ind.br | twitter.com/fgmwhiteness | youtube.com/fgmprodutosodonto | [email protected]

Developed product with the support:

RE

V. 0

0 -

01/0

6/10