Portable, stand alone Gas Conditioning System 100% corrosion resistance of the gas pathways No condensation on the way from the gas extraction point due to heated sampling line* Temperatur regulation to protect the physical condition of the ue gas sample More than 99% efficiency guaranteed Condensation of the ue gas humidity in the heat exchanger at 5° C Indication of the outlet dew point temperature on the front panel of the unit Individually adjustable dew point temperature High quality flue gas conditioning guarantees highly accurate measuring results. Condensation of the flue gas sample must be avoided in the pathway from the point of gas extraction to the flue gas analyzer. None of the target substances must be lost due to condensation. The gas conditioning system protects the analyzer against humidity and dust particles. Thus, long term measuring over a period of several hours becomes possible. MRU - over 30 years of innovative gas analysis Technical Data MRU 600 *Option Cooling capacity 100 kJ/h Inlet dew point 40°C up to 65°C max. (depending on flow rate) Outlet dew point + 5°C, Alarm at deviation of ± 3°C Cooler type Peltier controlled heat exchanger Flow volume 50 … 150l/h or 50 … 250l/h (w/ double heat exchanger) Power consumption 120W max. Ambient temperature +5°C up to +50°C Warm-up time appr. 5 minutes Power supply 230V 50/60 Hz Dimensions 410x360x210 mm (WxHxD) Weight 10 kg

Transcript of FLYER MRU600 · FLYER_MRU600.cdr Author: Seegräber;Martin Created Date: 12/4/2018 12:11:39 PM ...

Page 1: FLYER MRU600 · FLYER_MRU600.cdr Author: Seegräber;Martin Created Date: 12/4/2018 12:11:39 PM ...

Portable, stand alone Gas Conditioning System

100% corrosion resistance of the gas pathways

No condensation on the way from the gas extraction point due to heated sampling line*

Temperatur regulation to protect thephysical condition of the �ue gas sample

More than 99% efficiency guaranteed

Condensation of the �ue gas humidityin the heat exchanger at 5° C

Indication of the outlet dew point temperatureon the front panel of the unit

Individually adjustable dew point temperature

High quality flue gas conditioning guaranteeshighly accurate measuring results. Condensationof the flue gas sample must be avoided in thepathway from the point of gas extraction to theflue gas analyzer. None of the target substancesmust be lost due to condensation. The gasconditioning system protects the analyzer againsthumidity and dust particles. Thus, long termmeasuring over a period of several hours becomespossible.

MRU - over 30 years of innovative gas analysis

Technical Data

MRU 600

*Option

Cooling capacity 100 kJ/hInlet dew point 40°C up to 65°C max. (depending on flow rate)Outlet dew point + 5°C, Alarm at deviation of ± 3°CCooler type Peltier controlled heat exchangerFlow volume 50 … 150l/h or 50 … 250l/h (w/ double heat exchanger)Power consumption 120W max. Ambient temperature +5°C up to +50°CWarm-up time appr. 5 minutesPower supply 230V 50/60 HzDimensions 410x360x210 mm (WxHxD)Weight 10 kg