FLUSH MOUNTED CORNER GUARDS
24FMCG
IMPORTANT NOTES
1. ALL MATERIAL TO BE SUPPLIED IN STOCK LENGTHS. ALUMINUM RETAINER AND ACROVYN COVERS IN LENGTHS UP TO 20'-0".
THIS MATERIAL IS TO BE FIELD CUT USING QUALITY EQUIPMENT TO ENSURE THAT ALL CUTS ARE SQUARE. WHEN CUTTING
MATERIAL SECTIONS, CS RECOMMENDS USING AN 80-100 TOOTH CARBIDE TIPPED SAW BLADE OR EQUIVALENT, TO MINIMIZE
CHIPPING AND MAINTAIN JOINT ALIGNMENT.
2. ALL DIMENSIONS ARE TYPICAL.
3. FOR DRYWALL/PLASTER WALL CONSTRUCTION, IT IS RECOMMENDED FOR FASTENERS TO BE ENGAGED INTO METAL/WOOD
STUDS TO MAINTAIN MAXIMUM PULLOUT STRENGTH. IF DURING INSTALLATION YOU ENCOUNTER SPECIAL WALL CONDITIONS
THAT DO NOT ALLOW FOR DIRECT ATTACHMENT TO THE STUDS PLEASE CONSULT THE LOCAL AUTHORITY HAVING
JURISDICTION.
4. MATERIAL MUST REACH 65°F MIN. TO 75°F MAX. 24 HOURS PRIOR TO INSTALLATION. THIS IS ESSENTIAL TO MINIMIZE EXPANSION
AND CONTRACTION OF MATERIAL.
5. DUE TO 1 1/4" [31.8mm] NOSE RADIUS IT IS NOT RECOMMENDED TO INSTALL FS-10N, FS-10MN, OR SFS-10N AT PARTIAL HEIGHT.
6. FOR MORE INFORMATION ON FLUSH MOUNTED CORNER GUARDS SEE OUR WEBSITE AT www.c-sgroup.com.
SECTIONAL VIEW
PLEASE READ
PLEASE READ THESE INSTRUCTIONS THOROUGHLY
PRIOR TO BEGINNING THE FLUSH MOUNTED
CORNER GUARD INSTALLATION!
THIS INSTRUCTION SHEET IS INTENDED TO PROVIDE A
SPECIFIC GUIDE TO FOLLOW FOR THE INSTALLATION
OF THIS FLUSH MOUNTED CORNER GUARD.
CONTAINED WITHIN IS THE TECHNICAL INFORMATION
AND INSTALLATION TECHNIQUES REQUIRED TO
COMPLETE AN EFFICIENT, NEAT AND LONG-LASTING
INSTALLATION.
INSPECT ALL MATERIALS FOR DAMAGE OR MISSING
PARTS. IF YOU DISCOVER DAMAGED OR MISSING
MATERIALS, IN THE USA PLEASE NOTIFY THE FACTORY
AT (800) 233-8493, AND IN CANADA (888) 895-8955 FOR
CUSTOMER SERVICE.
FLUSH MOUNTED CORNER GUARD MUST BE
INSTALLED IN ACCORDANCE WITH THESE
INSTRUCTIONS! FAILURE TO FOLLOW THESE
INSTRUCTIONS MAY VOID ANY PRODUCT WARRANTIES
AND RESULT IN AN UNSUCCESSFUL INSTALLATION.
FOR SPECIFIC QUESTIONS REGARDING THE
INSTALLATION OF THIS FLUSH MOUNTED CORNER
GUARD PLEASE CALL THE FACTORY IN THE USA AT
(800) 233-8493 OR EMAIL
[email protected]. IN CANADA CALL
(888) 895-8955.
G.W.B (BY OTHERS)
FEATHERED
JOINT CEMENT
LEG
LENGTH
LEG
LENGTH
R1/4"
[R6.3mm]
Doc#: II-24FMCG Issue Date: 01/01/99 Rev Date: 10/12/16
FS-20NFS-10N
FS-10MN
SFS-10N SFS-20N
FS-10N MOD
-RETAINER IS SPLIT FOR ANGLES LESS THAN 78°
OR GREATER THAN 154°
- RETAINER IS FACTORY MODIFIED FOR ALL OTHER
ANGLES (EXCLUDING 90°)
FLUSH MOUNTED CORNER GUARDS
SECTIONAL VIEW
24FMCG
G.W.B (BY OTHERS)
3"
[76.6mm]
3"
[76.6mm]
STEEL/WOOD STUD
(BY OTHERS)
2"
[51.2mm]
FOAM TAPE
2"
[51.2mm]
G.W.B.
(BY OTHERS)
135°
3"
[76.2mm]
3"
[76.2mm]
R1"
[R25.4mm]
R1/4"
[R6.4mm]
R1/4"
[R6.4mm]
R1 1/4"
[R31.8mm]
R1 1/4"
[R31.8mm]
R1 1/4"
[R31.8mm]
STEEL/WOOD
STUD (BY OTHERS)
G.W.B.
(BY OTHERS)
STEEL/WOOD
STUD (BY OTHERS)
G.W.B (BY OTHERS)
G.W.B (BY OTHERS)
G.W.B (BY OTHERS)
STEEL/WOOD STUD
(BY OTHERS)
STEEL/WOOD STUD
(BY OTHERS)
STEEL/WOOD STUD
(BY OTHERS)
Doc#: II-24FMCG Issue Date: 01/01/99 Rev Date: 10/12/16
FLUSH MOUNTED CORNER GUARDS
COMPONENTS & WALL FASTENERS
24FMCG
FS-10N/FS-10MN ACROVYN COVER
(24U130xxx)
ACROVYN CHAMELEON COVER
(24U963xxx)
FS-20N ACROVYN COVER
(24U002xxx)
ACROVYN CHAMELEON COVER
(24U634xxx)
FS-10N/FS-20N
ALUMINUM RETAINER
1/2" DRYWALL (24A159000)
5/8" DRYWALL (24A166000)
FS-10MN
ALUMINUM RETAINER
1/2" DRYWALL (24A162000)
5/8" DRYWALL (24A168000)
(SEE SECTION ON PAGE 2 IF WALL IS
AN ANGLE OTHER THAN 135°)
SFS-10N ACROVYN COVER
(24U007xxx)
ACROVYN CHAMELEON COVER
(24U676xxx)
SFS-20N ACROVYN COVER
(24U004xxx)
ACROVYN CHAMELEON COVER
(24U622xxx)
WALL CONDITION SPECIFIED FASTENER
DRILL DIAMETERS
CS PART
NUMBER
WALL RETAINER
STEEL STUD/GYPSUM WALL
WOOD STUD/GYPSUM WALL
#6 X 1 5/8" BUGLE HEAD SMS N/A N/A 90H079002
SFS-10N/SFS-20N
ALUMINUM RETAINER
1/2" DRYWALL (24A160000)
5/8" DRYWALL (24A167000)
4" ALUMINUM BASE
(24F008000-FS10N )
(24F010000-FS10MN)
(24F009000-FS20N)
(24F011000-SFS10N)
(24F012000-SFS20N)
1" ALUMINUM
CLOSURE CAP
(24F094000-FS10N)
(24F096000-FS10MN)
(24F062000-FS20N)
(24F093000-SFS10N)
(24F063000-SFS20N)
GASKET
(24M009000-FS10N)
(24M018000-FS10MN)
(24M010000-FS20N)
(24M011000-SFS10N)
(24M012000-SFS20N)
6" ALUMINUM BASE
(24F145000-FS10N)
(24F149000-FS10MN)
(24F146000-FS20N)
(24F147000-SFS10N)
(24F144000-SFS20N)
3/4" FOAM TAPE
**SFS-10N ONLY**
(90M008002C)
Doc#: II-24FMCG Issue Date: 01/01/99 Rev Date: 10/12/16
NOTE:
DUE TO THE NOSE RADIUS, IT IS NOT
RECOMMENDED TO INSTALL FS-10N, FS-10MN,
OR SFS-10N AT PARTIAL HEIGHT.
FULL HEIGHT PARTIAL HEIGHT
STANDARD DEDUCTIONS
FLUSH MOUNTED CORNER GUARDS
LAYOUT VIEW
24FMCG
RETAINER
LENGTH
EQUALS
CEILING
HEIGHT
PLUS 2"
[50.8mm]
2"
[50.8mm]
BASE
HEIGHT
1/16" [1.6mm]
GASKET
COVER
LENGTH
EQUALS
RETAINER
LENGTH
MINUS
BASE
HEIGHT
AND
1/16"
[1.6mm]
FINISH CEILING
ALUMINUM RETAINER
FINISH FLOOR
RETAINER
HEIGHT
EQUALS
FINISH
HEIGHT
PLUS
1" [25.4mm]
BASE
HEIGHT
1/16" [1.6mm]
GASKET
COVER
LENGTH
EQUALS
FINISH
HEIGHT
MINUS
BASE
HEIGHT
AND
1/8" [3.2mm]
1/16" [1.6mm]
GASKET
1"
[25.4mm]
ALUMINUM CLOSURE
CAP
ALUMINUM
RETAINER
CEILING
HEIGHT
Doc#: II-24FMCG Issue Date: 01/01/99 Rev Date: 10/12/16
FULL HEIGHT PARTIAL HEIGHT
FLUSH MOUNTED CORNER GUARDS
TYPICAL ASSEMBLY
24FMCG
DRYWALL SETBACK CHART
FS-10N FS-10MN FS-20N SFS-10N SFS-20N
1/2" DRYWALL
2 11/16"
[68.3mm]
2 13/16"
[71.4mm]
2 11/16"
[68.3mm]
1 3/4"
[43.8mm]
1 3/4"
[43.8mm]
5/8" DRYWALL
2 5/8"
[66.7mm]
2 13/16"
[71.4mm]
2 5/8"
[66.7mm]
1 5/8"
[41.3mm]
1 5/8"
[41.3mm]
DRYWALL/
PLASTER
STEEL/WOOD
STUD
DRYWALL SETBACK
(REF. CHART BELOW)
SPECIFIED FASTENER
PRE-PUNCHED
HOLES
18"
[457.2mm]
MAX.
ALUMINUM
RETAINER
BLACK
ACROVYN
GASKET
ALUMINUM BASE
ACROVYN
COVER
DRYWALL/
PLASTER
STEEL/WOOD
STUD
ALUMINUM CLOSURE CAP
REQUIRED AT PARTIAL
HEIGHT APPLICATIONS
BLACK ACROVYN
GASKET
18"
[457.2mm]
MAX.
SPECIFIED
FASTENER
PRE-PUNCHED
HOLES
ALUMINUM
RETAINER
ACROVYN
COVER
BLACK
ACROVYN
GASKET
ALUMINUM BASE
Doc#: II-24FMCG Issue Date: 01/01/99 Rev Date: 10/12/16
1. WHEN INSTALLING THE GYPSUM BOARD OR PLASTER, CONSULT
THE CHART ON PAGE 5 TO DETERMINE THE SETBACK DISTANCE
TO PROVIDE A SNUG FIT WHEN THE RETAINER IS INSTALLED.
NOTE: FOR ODD-ANGLE CONDITIONS DRY FIT ALUMINUM BASE WITH
ALUMINUM RETAINERS TO AID IN DETERMINING DRYWALL SETBACK
AND PROPERLY POSITION RETAINERS ON CORNER OF WALL. IF WALL
IS LESS THAN 78° OR GREATER THAN 154°, ALUMINUM RETAINERS ARE
SPLIT INTO (2) PIECES.
2. ALIGN EACH RETAINER WITH THE CORNER AND SECURE EACH
LEG THROUGH THE WALL INTO METAL/WOOD STUDS USING THE
SPECIFIED FASTENERS. MAKE SURE THE RETAINER REMAINS
PLUMB WITH THE FINISH FLOOR.
3. INSERT ALUMINUM BASE CLOSURE AT THE BASE OF THE
RETAINER AND SECURE THE ACROVYN GASKET ON TOP BY
REMOVING THE PROTECTIVE COVERING TO EXPOSE THE
TRANSFER ADHESIVE. ALIGN GASKET WITH OUTSIDE EDGE.
NOTE: GASKETS FOR FS-10N MOD CORNER GUARDS ARE TO BE FIELD
MITERED.
4. A 1" [25.4mm] CLOSURE CAP IS TO BE INSTALLED AT TOP OF
RETAINER ON PARTIAL HEIGHT GUARDS FOLLOWING
PROCEDURES SIMILAR TO STEP 3.
5. APPLY 2" [50.8mm] JOINT TAPE ALONG THE EDGE OF THE DRYWALL
AND THE ALUMINUM RETAINER WITH INTEGRATED CORNER BEAD.
FINISH THE INSTALLATION BY APPLYING A UNIFORM FEATHERED
JOINT AT THIS LOCATION AS PER STANDARD CONSTRUCTION
PRACTICES. ALLOW TO DRY AND THEN SAND AS REQUIRED.
APPLY ADDITIONAL COATS, AS REQUIRED, TO PROVIDE A
UNIFORM AND NEAT FINISH. APPLY THE PROCEDURE TO ANY
"CLOSURE" CAPS USED ON PARTIAL HEIGHT INSTALLATIONS.
6. FINISH WALL SURFACE AS SPECIFIED. BE SURE THAT THE
SELECTED FINISH IS APPLIED TO THE INSIDE SURFACE OF THE
REAR "CONTOURED" PORTION OF THE ALUMINUM RETAINER.
NOTE: ON MODEL SFS-10N: APPLY NEOPRENE TAPE TO NOSE OF THE
RETAINER.
7. FINISH INSTALLATION BY SNAPPING THE ACROVYN COVER ONTO
THE RETAINER.
FLUSH MOUNTED CORNER GUARDS
TYPICAL ASSEMBLY
24FMCG
This document is the property of Construction Specialties, Inc. and contains CONFIDENTIAL PROPRIETARY INFORMATION
that is not to be disclosed to third parties and is not to be used without approval in writing from Construction Specialties, Inc.
Muncy, Pennsylvania ● (800) 233-8493 ● Fax (570) 546-5169
Mississauga Ontario ● (888) 895-8955 ● Fax (905) 274-6241
www.c-sgroup.com
DRYWALL
TAPE
FEATHERED
JOINT
WALL FINISH
MATERIAL
COVE BASE
(BY OTHERS)
BLACK ACROVYN
GASKET
WALL
FINISH
MATERIAL
FEATHERED
JOINT
ACROVYN
COVER
DRYWALL
SETBACK
(REF. CHART
ON PAGE 5)
WALL FINISH
MATERIAL
Doc#: II-24FMCG Issue Date: 01/01/99 Rev Date: 10/12/16