FLUSH GLAZE SERIES 3000 THERMAL MULTIPLANE...

74
*AC 119 1 *AC-108-1 PART #: 6533 11/32" 1-1/4" F *AC-119-1 PART #: 6295 *AC-119-1 PART #: 6295 TYP. #25 TAP HOLE ROLL PIN *AC-108-1 PART #: 6533 11/32" 1-1/4" 1-1/4" 11/32" 7/16" 7/16" ROLL PIN FS-7 FS-6 FS-6 29/32" TYP. *AC-108-1 PART #: 6533 FG-3103 *AC-119-1 PART #: 6295 *AC-119-1 PART #: 6295 TYP. #25 TAP HOLE ROLL PIN *AC-108-1 PART #: 6533 11/32" 1-3/4" 1-1/4" 1-1/4" 11/32" 7/16" 7/16" ROLL PIN TYP. FG-3142-S FG-3161-S FS-6 11/32" TYP. FS-7 FS-6 33 FG-3142-S FG-3161-S FS-6 FS-7 FS-6 F L U S H G L A Z E S E R I E S 3 0 0 0 & S E R I E S 3 0 0 0 T H E R M A L M U L T I P L A N E I N S T A L L A T I O N I N S T R U C T I O N M A N U A L January 2005

Transcript of FLUSH GLAZE SERIES 3000 THERMAL MULTIPLANE...

*AC 119 1

*AC-108-1 PART #: 6533

11/32"

1-1/4"

F

*AC-119-1 PART #: 6295

*AC-119-1 PART #: 6295

TYP. #25TAP HOLE

ROLLPIN

*AC-108-1 PART #: 6533

11/32"

1-3/4"

1-1/4"

1-1/4"

11/32"

7/16"

7/16"

ROLLPIN

TYP.

FS-7FS-6

FS-629/32"

TYP.

*AC-108-1 PART #: 6533

FG-3103

*AC-119-1 PART #: 6295

*AC-119-1 PART #: 6295

TYP. #25TAP HOLE

ROLLPIN

*AC-108-1 PART #: 6533

11/32"

1-3/4"

1-1/4"

1-1/4"

11/32"

7/16"

7/16"

ROLLPIN

TYP.

FG-3142-S

FG-3161-S

FS-6

11/32"TYP.

FS-7FS-6

33

FG-3142-S

FG-3161-S

FS-6

FS-7FS-6

F L U S H G L A Z E

S E R I E S 3 0 0 0

&

S E R I E S 3 0 0 0

T H E R M A L

M U L T I P L A N E

I N S T A L L A T I O N

I N S T R U C T I O N

M A N U A L

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

1January 2005

General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 2 – 4

Outside Glaze

Non Thermal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 5 – 11

Thermal Slot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 12 – 18

Thermal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 19 – 27

Inside Glaze Screw Spline

Non Thermal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 28 – 33

Thermal Slot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 34 – 40

Thermal Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 41 – 45

Stack System Outside Glaze . . . . . . . . . . . . . . . . . . . . . .Page 46 – 51

FG-3000 Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 52 – 57

Multi-Plane Outside Glaze . . . . . . . . . . . . . . . . . . . . . . . .Page 58 – 63

Multi-Plane Inside Glaze . . . . . . . . . . . . . . . . . . . . . . . . .Page 64 – 67

Multi-Plane Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 68 – 72

Infill Thickness Options Chart . . . . . . . . . . . . . . . . . . . . . . . . . .Page 72

CONTENT

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

2

GENERAL INFORMATION

January 05

The Vistawall Series 3000 (2 x 4 1/2) system represents the latest in productdevelopment technology complemented by dealer on-the-job input and expe-rience. Proper use of these systems will assure optimum results in erectionand long term performance

Vistawall does not control the application nor selection of its product configurations, sealant or glazing materials and assumes no responsibilitythereof. It is the responsibility of the owner, architect and installer to makethese selections in strict compliance with applicable laws and building codes.

PROTECTION AND STORAGE:

Handle the material carefully. Do not drop from the truck. Stack with ade-quate separation so that the material will not rub together. Store material offthe ground. Protect against the elements and other construction hazards byusing a well ventilated covering. Remove material from package if it is wet oris located in a damp area.

CHECK MATERIAL:

Check all material upon arrival for quality and to assure against shipping damage. Any visible damage must be noted on the freight bill at the time ofreceipt. If a claim is required, then the receiving party must process a claimwith the freight company.

Completely check construction which will receive your materials against con-tract documents. Notify the general contractor by letter of any discrepanciesbefore proceeding with the work. Failure to do so constitutes acceptance ofwork by other trades.

Check shop drawings and installation instructions to become familiar with theproject. The shop drawings take precedence and include specific details forthe project. The installation instructions are of a general nature and cover themost common conditions. Due to varying job conditions, all sealants usedshould be approved by the sealant manufacture, to insure they will functionfor conditions shown on instructions and shop drawings. They must be com-patible with all surfaces in which adhesion is required, including other sealantsurfaces. Use primers where directed by manufacturer of sealants. Be sureto properly store sealants at recommended temperatures and check sealantfor remainder of shelf life before using.

FIELD CONDITIONS:

• Do not install wall if there is a walk way with a downslope towards anentrance or a storefront

• All materials to be installed plumb, level, and true. Aluminum to be placedin direct contact with the masonry or incompatible materials, should be iso-lated with a heavy coat of zinc-chromate or bituminous paint.

• After sealant is set and a representative amount of the wall has beenglazed (250 square feet or more), run a water hose to check installation. Onlarge jobs, hose test should be repeated during glazing operation. Testshould be conducted in accordance with AAMA 501.2 specifications.

• Coordinate protection of installed materials with general contractors andother trades.

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

3

GENERAL INFORMATION CONT.

January 2005

CLEANING MATERIALS:

Cement, plaster, terrazzo, alkaline and acid based materials used to cleanmasonry are very harmful to finishes and should be removed with water anda mild soap immediately or permanent staining will occur. A spot test is rec-ommended before any cleaning agent is used.

Over the years many components were added to our flush glaze systems.Items like FG-1135 flashing and the two piece MO-244 and MO-242/243head can are not shown in this manual but remain in the detail catalog andprice book. There are many ways to install store front products. This manualrepresents recommendations for best results.

EXPANSION JOINTS:

Expansion joints and perimeter seals shown in these instructions and in theshop drawings are shown at normal size. Actual dimensions may vary due toperimeter conditions and/or differences in metal temperature between thetime of fabrication and time of installation. For example, a 12 foot unre-strained length of aluminum extrusion can expand or contract 3/32 of an inchover a 50° F change. Any movement potential should be accounted for at thetime of the installation.

THERMAL IMPROVEMENT SUGGESTIONS:

To maintain or improve your wall installation, the following items should beconsidered:

A. Blinds or drapes prevent warm air from washing the window.

B. Warm air ventilators too far from the window will not adequately washthe window with air to prevent condensation.

C. In extreme conditions, the fan of the heating system should not cycleon and off but should run continuously.

D. Some heating systems have a water injection feature that can raisehumidity levels. The higher the humidity level the more likely conden-sation or frost will form. Raising the temperature and reducing thehumidity will usually solve the problem.

E. On rare occasions, an extremely cold storm may cause frost to appearon the glass or framing. A space heater and electric fan blowing alongthe plane of the window wall can reduce or eliminate this temporarycondition.

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

4 January 2005

X

NOT ENOUGH METAL EXPOSED TO INTERIOR AT X.

NOT RECOMMENDED PREFERRED

TO DERIVE THE GREATEST BENEFIT FROM YOUR STOREFRONTINSTALLATION, WE RECOMMEND YOU REVIEW THE FOLLOWING.

SHIM & AIR SPACE.MIN. 1/4" THICK.

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

5

OUTSIDE GLAZENON THERMAL SCREW SPLINE FRAME ASSEMBLY

January 2005

SCHNEE-MOORHEADSM-5601 1/8"X1/2" TACKY TAPE.VW PART # 4666 (OR EQUAL)NOTE: KEEP TAPE AWAY FROMSCREW SPLINES.

FS-8(TYP.)

PART #: 10223

(TYP.)

2-11/16"

(TYP.)

1-3/4"

FG-3102

FG-3100

1/4"

1-3/4"

1-3/4"

1/4"

FG-3103

FG-3142

FG-3161

TOP 0FHORIZONTAL

SEALANTEXTERIOR ONLY

"F" (.257 DIA)DRILL THRU TYP.

NOTE: USE RAZOR KNIFE TOTRIM EXCESS SEALANT TAPE.DO NOT PULL TAPE TO TRIM.

29/32"

DJ-5 DRILL FIXTURE PART # 4562 IS ALSO AVAILABLE TO AID FABRICATION FOR SCREW SPLINE FRAME ASSEMBLY.FOR FASTER, MORE ACCURATE HOLE FABRICATION, WE RECOMMEND THE VISTAWALL EZ PUNCH FABRICATION TOOL.TM

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

6

OUTSIDE GLAZENON THERMAL SHEAR BLOCK FRAME ASSEMBLY

29/32"

*AC-119-1 PART #: 6295

*AC-119-1 PART #: 6295

TYP. #25TAP HOLE

ROLLPIN

*AC-108-1 PART #: 6533

9/16"

11/32"

1-3/4"

1-1/4"

1-1/4"

11/32"

7/16"

7/16"

ROLLPIN

TOP 0FHORIZONTAL

2-11/16"

TYP.

NOTE: USE RAZOR KNIFE TOTRIM EXCESS SEALANT TAPE.DO NOT PULL TAPE TO TRIM.

*PACKAGE INCLUDES SCREWSAND ROLL PIN

SCHNEE-MOORHEADSM-5601 1/8"X1/2" TACKY TAPE.VW PART # 4666 (OR EQUAL)NOTE: KEEP TAPE AWAY FROMSCREW SPLINES.

TYP. #11 CLEAR HOLE

FG-3103

FG-3142

FG-3161

FG-3107

.250 DIA. TYP.FOR ROLL PIN

#11 TAPHOLE TYP.

FS-7FS-6

FS-629/32"

1/4"

TYP.

DJ-6 DRILL FIXTURE PART # 4563 IS ALSO AVAILABLE TO AID FABRICATION FOR SCREW SPLINE FRAME ASSEMBLY.

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

7

OUTSIDE GLAZENON THERMAL SILL FLASHING INSTALLATION

SEAL WITH A NON-SKINNING,NON-HARDENING SEALANT.FILL BREAK IN FLASHINGAND SEAL UNDER SPLICE.

SEALANT

FG-2169

FG-2000-FP-7 PART #: 7968

1/4" NOM.

FG-2000-FP-4PART #: 7949

FLASHING ANCHORS MUSTBE CAP SEALED.

SHIM FLASHING ATLOW SPOTS ONLY.

NOTE: SILL FLASHINGSHOULD BE LEVEL ANDMAKE SURE IT IS NOT TILTEDTOWARD THE INTERIOR.

SILL SPLICE

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

8

OUTSIDE GLAZENON THERMAL FRAME INSTALLATION

FG-1122 X 4" LONG(PART SOLD IN STOCK LENGTHS.)

1. ASSEMBLY WITHOUT FLASHING IS NOT RECOMMENDED.2. DO NOT ANCHOR WALL THRU VERTICAL LEG OF FLASHING.

SEALANT

ACCESS HOLE AT ALL ANCHOR LOCATIONS.(SIZE DETERMINED BY ANCHOR.)

DRILL CLEAR HOLE IN FLASHING THOUGHANCHOR CLIP. THEN INJECT SEALANT INTOHOLE IN FLASHING AND UNDER ANCHOR CLIP.

ANCHOR SIZE AND FREQUENCY SHOULD BE DETERMINED BY STRUCTURAL REQUIREMENTS. SILL ANCHOR FG-2000-FP-3 AND HEAD ANCHOR FG-2122 SHOULD BE LOCATED SO THATTHE ANCHOR IS NOT MORE THAN 4" FROM EACH SIDE OF THE MULLION.

FG-2000-FP-3PART #: 7944

FG-2188PVC PROFILE

USED TO IMPROVEINSTALLATION OFBACKER ROD AND

PERIMETER SEALANT.(OPTIONAL)

CLEAR HOLE(SIZE DETERMIMED BY ANCHOR.)

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

9

OUTSIDE GLAZE NON THERMAL SILL FLASHINGINSTALLATION AND PERIMETER SEAL

APPLY SEALANT ALONG LENGTH OF SUB SILLAT AREAS A & B.

LAY FLASHING ON SLAB AND SHIM ONLY AT LOWAREAS. RESEAL AT SHIM AREAS.

SPACE BETWEEN SILL AND FLASHING (C) TO BECONTINUOUSLY SEALED EXCEPT FOR 1/2"-3/4" SPACE UNDER VERTICAL MULLIONS FOR WEEPAGE.PRIOR TO INSTALLING FRAME, APPLY SEALANTCONTINUOUSLY ALONG SILL FLASHING (D).THIS WILL PROVIDE CONTINUOUS SEALBETWEEN SILL AND SILL FLASHING.

THE QUALITY OF THE INSIDE AND OUTSIDEPERIMETER SEALS (C AND E) MAY BE IMPROVEDBY USING FG-2188 RIGID PVC FILLER.THE PART MAY BE USED IN FULL LENGTHS OR CUTINTO PIECES. ITS PURPOSE IS TO PROVIDESUPPORT FOR THE BACKER ROD REGARDLESSOF JOINT OR SIZE. PERIMETED SEAL (F) IS FORCOSMETIC PURPOSES AND IS OPTIONAL.

FG-2000-FP-3 PART #: 7944

D

A

C

B

F

NOTE: 1/2"-3/4" WEEP HOLEREQUIRED IN SEALANT ATFLASHING (C)AT CENTERLINE OF MULLION.

E

E E

E

FG-21224" LONG

(PARTS SOLD INSTOCK LENGTHS.)

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

10

OUTSIDE GLAZESEALANT PROCEDURE FOR DOOR FRAME AT FLASHING

LEAVE FRONT OF DOOR JAMB CLEAR OFSEALANT FOR DRAINAGE PURPOSES.

*USE SHEAR BLOCKS AS SHOWN ON PAGE 6 TO SECURE TO TUBULAR FRAME.

DOOR FRAME IS ANCHORED BY FASTENERS THROUGH THRESHOLDAND THROUGH DOOR FRAME HEADER.

DO NOT FABRICATE 2 PIECE DOOR FRAMES WITH POUR & DEBRIDGE PROFILES.

FLASHING IS BED INSEALANT AT DOOR JAMB.

RUN SEALANT ONE INCHABOVE FLASHING.

FG-3156

FG-3155

FG-2145

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

11

OUTSIDE GLAZENON THERMAL GLAZING PROCEDURE

NOTE:FIRST, WETBOTTOM OF SETTINGBLOCKS WITH SOAPYWATER. ONCE GLASS IS SET,PUSH AGAINST GASKET ATSETTING BLOCK AREA.FAILURE TO DO SO MAY CAUSEDIAGONAL CRACKS TOWARDSSETTING BLOCKS DUE TO GLASSBENDING WHILE INSTALLINGGASKET(S) IN CORNERS.

VERTICAL GASKETSRUN THRU.

FG-1133PART #: 364

MITER HORIZONTAL GASKETTO FIT VERTICAL GASKET.

150

FG-3146PART #: 6471FG-3144

FG-1000-FP-2PART #: 6887SET IN PLACEWITH SEALANT.

GLAZING INSTALLATION INSTRUCTIONS GLASS SIZE7/8" OVER DAY LIGHT OPENING SETTING BLOCKSET AT 1/4 POINT OR 1/8 POINT OF HORIZONTAL LENGTHDEPENDING ON LITE SIZE. WATER DIVERTERSGLAZE FROM BOTTOM TO TOP. INSTALL WATER DIVERTERS INHORIZONTAL ABOVE, AFTER LITE BELOW IS IN POSITION. GLAZING GASKETGASKET MAY BE INSTALLED ON ONE OR BOTH SIDESSIMULTANEOUSLY. PROVIDE 3/8" ADDITIONAL GASKETFOR EACH FOOT OF DAYLIGHT OPENING TO PROVIDEADEQUATE COMPRESSION FOR THE GLAZING INFILL.NOTE: CLEAN GASKET WITH ISOPROPYL ALCOHOL PRIOR TOSEALING CORNERS.

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

12

OUTSIDE GLAZETHERMAL SLOT™ SCREW SPLINE FRAME ASSEMBLY

1-3/4"

FS-8(TYP.)

PART #: 10223

(TYP.)(TYP.)

2-11/16"

SCHNEE-MOORHEADSM-5601 1/8"X1/2" TACKY TAPE.VW PART # 4666 (OR EQUAL)NOTE: KEEP TAPE AWAY FROMSCREW SPLINES.

TOP 0FHORIZONTAL

SEALANTEXTERIOR ONLY

"F" (.257 DIA)DRILL THRU TYP.

FG-3102-S

FG-3100-S

FG-3103-S

FG-3142-S

FG-3161-S

1/4"

1-3/4"

1-3/4"

1/4"

NOTE: USE RAZOR KNIFE TOTRIM EXCESS SEALANT TAPE.DO NOT PULL TAPE TO TRIM.

29/32"

DJ-5 DRILL FIXTURE PART # 4562 IS ALSO AVAILABLE TO AID FABRICATION FOR SCREW SPLINE FRAME ASSEMBLY.FOR FASTER, MORE ACCURATE HOLE FABRICATION, WE RECOMMEND THE VISTAWALL EZ PUNCH FABRICATION TOOL.TM

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

13

OUTSIDE GLAZETHERMAL SLOT™ SHEAR BLOCK FRAME ASSEMBLY

*AC-119-1 PART #: 6295

*AC-119-1 PART #: 6295

TYP. #25TAP HOLE

ROLLPIN

*AC-108-1 PART #: 6533

9/16"

11/32"

1-3/4"

1-1/4"

1-1/4"

11/32"

7/16"

7/16"

ROLLPIN

TOP 0FHORIZONTAL

2-11/16"

TYP.

NOTE: USE RAZOR KNIFE TOTRIM EXCESS SEALANT TAPE.DO NOT PULL TAPE TO TRIM.

SCHNEE-MOORHEADSM-5601 1/8"X1/2" TACKY TAPE.VW PART # 4666 (OR EQUAL)NOTE: KEEP TAPE AWAY FROMSCREW SPLINES.

TYP. #11 CLEAR HOLE

FG-3103-S

FG-3142-S

FG-3161-S

FG-3107-S

.250 DIA. TYP.FOR ROLL PIN

#11 TAPHOLE TYP.

FS-6

11/32"

29/32"

TYP.

TYP.

FS-7FS-6

*PACKAGE INCLUDES SCREWSAND ROLL PIN

29/32"

DJ-6 DRILL FIXTURE PART # 4563 IS ALSO AVAILABLE TO AID FABRICATION FOR SCREW SPLINE FRAME ASSEMBLY.

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

14

OUTSIDE GLAZETHERMAL SLOT™ SILL FLASHING INSTALLATION

SEAL WITH A NON-SKINNING,NON-HARDENING SEALANT.FILL BREAK IN FLASHINGAND UNDER SPLICE.

FG-3000-FP-14PART #: 6984

A SHIM UNDER FLASHINGIS THE PREFERRED METHODFOR BEST THERMAL RESULTS.

SEALANT

FG-3223

FG-3000-FP-4PART #: 7947

FLASHING ANCHORSMUST BE CAP SEALED.

FG-3000-FP-9/10 PART #: 7960

1/4" NOM.

NOTE: SILL FLASHINGSHOULD BE LEVEL ANDMAKE SURE IT IS NOT TILTEDTOWARD THE INTERIOR.

SILL SPLICE

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

15

OUTSIDE GLAZETHERMAL SLOT™ FRAME INSTALLATION

FG-3000-FP-14PART #: 6984

FS-62 PER ANCHOR#25 TAP HOLE

11/32"

ANCHOR SIZE AND FREQUENCY SHOULD BE DETERMINED BY STRUCTURAL REQUIREMENTS. SILL ANCHOR FG-3000-FP-14 AND HEAD ANCHOR FG-2122 SHOULD BE LOCATED SO THATTHE ANCHOR IS NOT MORE THAN 4" FROM EACH SIDE OF THE MULLION.

FG-2188PVC PROFILE

USED TO IMPROVEINSTALLATION OFBACKER ROD AND

PERIMETER SEALANT.(OPTIONAL)

FG-2122 X 4" LONG(PART SOLD IN STOCK LENGTHS.)

CLEAR HOLE(SIZE DETERMIMED BY ANCHOR.)

1. ASSEMBLY WITHOUT FLASHING IS NOT RECOMMENDED.2. DO NOT ANCHOR WALL THRU VERTICAL LEG OF FLASHING.

NOTE: PRIOR TO INSTALLING FRAME, APPLY SEALANT CONTINUOUSLY ALONG SILL FLASHING. THIS WILL PROVIDE CONTINUOUS SEAL BETWEEN SILL AND SILL FLASHING.

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

16

OUTSIDE GLAZE THERMAL SLOT™ FLASHING INSTALLATION AND PERIMETER SEAL

C

C

FG-21224" LONG

(PARTS SOLD INSTOCK LENGTHS.)

C C

APPLY SEALANT ALONG LENGTH OF SUB SILLAT POINT A.

PRIOR TO INSTALLING FRAME, APPLY SEALANTCONTINUOUSLY ALONG SILL FLASHING (B).THIS WILL PROVIDE CONTINUOUS SEALBETWEEN SILL AND SILL FLASHING.

THE QUALITY OF THE INSIDE AND OUTSIDEPERIMETER SEALS (C ) MAY BE IMPROVED BYUSING FG-2188 RIGID PVC FILLER.THE PART MAY BE USED IN FULL LENGTHS OR CUTINTO PIECES. ITS PURPOSE IS TO PROVIDESUPPORT FOR THE BACKER ROD REGARDLESSOF JOINT OR SIZE. PERIMETED SEAL (D) IS FORCOSMETIC PURPOSES AND IS OPTIONAL.

B

B

D

FG-3000-FP-14PART #: 6984

A

E

NOTE: 1/4" WEEP HOLEREQUIRED IN FLASHING (E)AT MID-LITE.

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

17

OUTSIDE GLAZE THERMAL SLOT™ SEALANT PROCEDURE FOR DOOR FRAME AT FLASHING

FG-3155

FG-3156

FG-2145

LEAVE FRONT OF DOOR JAMB CLEAR OFSEALANT FOR DRAINAGE PURPOSES.

*USE SHEAR BLOCKS AS SHOWN ON PAGE 13 TO SECURE TO TUBULAR FRAME.

DOOR FRAME IS ANCHORED BY FASTENERS THROUGH THRESHOLDAND THROUGH DOOR FRAME HEADER.

DO NOT FABRICATE 2 PIECE DOOR FRAMES WITH POUR & DEBRIDGE PROFILES.

FLASHING IS BED INSEALANT AT DOOR JAMB.

RUN SEALANT ONE INCHABOVE FLASHING.

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

18

OUTSIDE GLAZETHERMAL SLOT™ GLAZING PROCEDURE

NOTE:FIRST, WETBOTTOM OF SETTINGBLOCKS WITH SOAPYWATER. ONCE GLASS IS SET,PUSH AGAINST GASKET ATSETTING BLOCK AREA.FAILURE TO DO SO MAY CAUSEDIAGONAL CRACKS TOWARDSSETTING BLOCKS DUE TO GLASSBENDING WHILE INSTALLINGGASKET(S) IN CORNERS.

VERTICAL GASKETSRUN THRU.

MITER HORIZONTAL GASKETTO FIT VERTICAL GASKET.

150

GLAZING INSTALLATION INSTRUCTIONS GLASS SIZE7/8" OVER DAY LIGHT OPENING SETTING BLOCKSET AT 1/4 POINT OR 1/8 POINT OF HORIZONTAL LENGTHDEPENDING ON LITE SIZE. WATER DIVERTERSGLAZE FROM BOTTOM TO TOP. INSTALL WATER DIVERTERS INHORIZONTAL ABOVE, AFTER LITE BELOW IS IN POSITION. GLAZING GASKETGASKET MAY BE INSTALLED ON ONE OR BOTH SIDESSIMULTANEOUSLY. PROVIDE 3/8" ADDITIONAL GASKETFOR EACH FOOT OF DAYLIGHT OPENING TO PROVIDEADEQUATE COMPRESSION FOR THE GLAZING INFILL.NOTE: CLEAN GASKET WITH ISOPROPYL ALCOHOL PRIOR TOSEALING CORNERS. *HORIZONTAL TAPECLEAN SURFACE AND APPLY TAPE FIRMLY BEFORE INSTALLINGWATER DIVERTERS.

FG-1133PART #: 364

FG-3146PART #: 6471

FG-1000-FP-2PART #: 6887SET IN PLACEWITH SEALANT.

*4516-1 TAPEPART #: 207

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

19

OUTSIDE GLAZEPOUR & DEBRIDGE SCREW SPLINE FRAME ASSEMBLY

SCHNEE-MOORHEADSM-5601 1/8"X1/2" TACKY TAPE.VW PART #: 4666 (OR EQUAL)NOTE: KEEP TAPE AWAY FROMSCREW SPLINES.

FS-8(TYP.)

PART #: 10223

(TYP.)

2-11/16"

(TYP.)

1-3/4"

FG-3232

FG-3231

1-3/4"

FG-3197

FG-3198

FG-3231

1-3/4"

TOP 0FHORIZONTAL

SEALANTEXTERIOR ONLY

"F" (.257 DIA)DRILL THRU TYP.

1/4"

NOTE: USE RAZOR KNIFE TOTRIM EXCESS SEALANT TAPE.DO NOT PULL TAPE TO TRIM.

29/32"

DJ-5 DRILL FIXTURE PART # 4562 IS ALSO AVAILABLE TO AID FABRICATION FOR SCREW SPLINE FRAME ASSEMBLY.FOR FASTER, MORE ACCURATE HOLE FABRICATION, WE RECOMMEND THE VISTAWALL EZ PUNCH FABRICATION TOOL.TM

1/4"

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

20

OUTSIDE GLAZEPOUR & DEBRIDGE SHEAR BLOCK FRAME ASSEMBLY

11/16"2-11/16"

SCHNEE-MOORHEADSM-5601 1/8"X1/2" TACKY TAPE.VW PART #: 4666 (OR EQUAL)NOTE: KEEP TAPE AWAY FROMSCREW SPLINES.

#11 TAPHOLE TYP.

*AC-108-1 PART #: 6533

TYP. #11 CLEAR HOLE

FG-3231

*AC-119-1 PART #: 6533

1-3/4"

1-1/4"

7/16"

ROLLPIN

TYP.

FG-3197

FS-7FS-6

1-1/4"

11/32"

7/16"

11/32"

29/32"

TYP.

TYP.

*AC-119-1 PART #: 6533

TYP. #25TAP HOLE

ROLLPIN

NOTE: USE RAZOR KNIFE TOTRIM EXCESS SEALANT TAPE.DO NOT PULL TAPE TO TRIM.

FG-3198

FS-6

*PACKAGE INCLUDES SCREWSAND ROLL PIN

TOP 0FHORIZONTAL

DRILL (.250)DIA. HOLE FOR

ROLL PIN

29/32"

11/32"

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

21

OUTSIDE GLAZEPOUR & DEBRIDGE SILL FLASHING INSTALLATION

1/4" NOM.

FG-3000-FP-15PART # 637

A SHIM UNDER FLASHINGIS THE PREFERRED METHODFOR BEST THERMAL RESULTS.

SEALANT

FG-3223

FG-3000-FP-4PART #: 7947

FLASHING ANCHORSMUST BE CAP SEALED.

NOTE: SILL FLASHINGSHOULD BE LEVEL ANDMAKE SURE IT IS NOT TILTEDTOWARD THE INTERIOR. FG-3000-FP-9/10

PART #: 7960

SEAL WITH A NON-SKINNING,NON-HARDENING SEALANT.FILL BREAK IN FLASHINGAND UNDER SPLICE.

SILL SPLICE

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

22

SUPPLEMENTAL INSTALLATION INSTRUCTIONS FORFG-3413 SILL RECEPTOR

FG-3413 SILL RECEPTOR

ANCHOR FLASHING WITH 4" FROM EITHERSIDE OF INTERMEDIATE MULLIONS ANCHOR

SIZE AND FREQUENCY SHOULD BEDETERMINED BY STRUCTURAL REQUIREMENTS.

CAP SEAL FLASHING ANCHORS AS SHOWN.

NOTE: IF A TWO PIECE HEAD RECEPTORIS NOT USED, A 1/4” MINIMUM CLEARANCEIS REQUIRED AT THE HEAD CONDITION TOALLOW FRAME INSTALLATION.

NOTE: THE FG-3413 SILL RECEPTOR ISDESIGNED TO WITHSTAND A MAXIMUMEND REACTION OF 600 LBS.

SEAL END DAM TOSILL RECEPTOR.

SHIM UNDERSILL RECEPTOR.

FG-3413 SILL RECEPTOR

NOTE: INSTALL SILL RECEPTOR LEVEL

FG3000-FP-47

1/4" NOMINAL

SEAL WITH A NON-SKINNINGNON-HARDENING SEALANT.FILL BREAK IN FLASHINGAND UNDER SPLICE.

FG3000-FP-46

SEAL SILL RECEPTORVERTICAL SPLICE JOINT

INSTALL SPLICE SLEEVE

INSTALL SILL RECEPTOR & END DAM

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

23

SUPPLEMENTAL INSTALLATION INSTRUCTIONS FORFG-3413 SILL RECEPTOR

JUST PRIOR TO FRAME INSTALLATION, APPLYCONTINUOUS SEALANT ALONG GROOVE IN FRONTAND BACK LEGS OF SILL RECEPTOR AND AROUNDJOINT AS SHOWN. IMMEDIATELY INSTALL FRAMEINTO SILL.

SET FRONT OF FRAME INSILL RECE

1/4" WEEP HOLE REQUIREDAT MID-LITE

PTOR AND TILTBACK INTO PLACE.

SEAL SILL RECEPTOR SPLICE JOINTSUP VERTICAL LEG OF RECEPTOR ANDMARRY INTO PERIMETER SEAL.

CLEAN EXCESSSEALANT AWAY.

INTERIOR PERIMETER SEALAT SILL IS OPTIONAL AND FORCOSMETIC PURPOSES ONLY.

INSTALL FRAME & INTERIORSPLICE SEAL

INSTALL SILL RECEPTOR TO FRAME INTERIOR SEAL

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

24

OUTSIDE GLAZEPOUR & DEBRIDGE FRAME INSTALLATION

9 /32"

FS-62 PER ANCHOR#25 TAP HOLE

FG-3000-FP-15PART #: 637

FG-3223

ANCHOR SIZE AND FREQUENCY SHOULD BE DETERMINED BY STRUCTURAL REQUIREMENTS. SILL ANCHOR FG-3000-FP-14 AND HEAD ANCHOR FG-2122 SHOULD BE LOCATED SO THATTHE ANCHOR IS NOT MORE THAN 4"AWAY FROM EACH SIDE OF THE MULLION.

FG-2188PVC PROFILE

USED TO IMPROVEINSTALLATION OFBACKER ROD AND

PERIMETER SEALANT.(OPTIONAL)

FG-2122 X 4" LONG(PART SOLD IN STOCK LENGTHS.)

CLEAR HOLE(SIZE DETERMIMED BY ANCHOR.)

1. ASSEMBLY WITHOUT FLASHING IS NOT RECOMMENDED.2. DO NOT ANCHOR WALL THRU VERTICAL LEG OF FLASHING.

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

25

OUTSIDE GLAZE POUR & DEBRIDGE SILL FLASHINGINSTALLATION AND PERIMETER SEAL

C C

D

FG-3000-FP-15PART #: 637

A

E

C

C

FG-21224" LONG

(PARTS SOLD INSTOCK LENGTHS.)

APPLY SEALANT ALONG LENGTH OF SUB SILLAT POINT A.

PRIOR TO INSTALLING FRAME, APPLY SEALANTCONTINUOUSLY ALONG SILL FLASHING (B).THIS WILL PROVIDE CONTINUOUS SEALBETWEEN SILL AND SILL FLASHING.

THE QUALITY OF THE INSIDE AND OUTSIDEPERIMETER SEALS (C ) MAY BE IMPROVED BYUSING FG-2188 RIGID PVC FILLER.THE PART MAY BE USED IN FULL LENGTHS OR CUTINTO PIECES. ITS PURPOSE IS TO PROVIDESUPPORT FOR THE BACKER ROD REGARDLESSOF JOINT OR SIZE. PERIMETED SEAL (D) IS FORCOSMETIC PURPOSES AND IS OPTIONAL.

NOTE: 1/4" WEEP HOLEREQUIRED IN FLASHING (E)AT MID-LITE.

B

B

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

26

OUTSIDE GLAZE POUR & DEBRIDGE SEALANT PROCEDURE FOR DOOR FRAME AT FLASHING

FG-3155

FG-2145

LEAVE FRONT OF DOOR JAMB CLEAR OFSEALANT FOR DRAINAGE PURPOSES.

*USE SHEAR BLOCKS AS SHOWN ON PAGE 13 TO SECURE TO TUBULAR FRAME.

DOOR FRAME IS ANCHORED BY FASTENERS THROUGH THRESHOLDAND THROUGH DOOR FRAME HEADER.

DO NOT FABRICATE 2 PIECE DOOR FRAMES WITH POUR & DEBRIDGE PROFILES.

FLASHING IS BED INSEALANT AT DOOR JAMB.

RUN SEALANT ONE INCHABOVE FLASHING.

FG-3156

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

27

OUTSIDE GLAZEPOUR & DEBRIDGE GLAZING PROCEDURE

VERTICAL GASKETSRUN THRU.

MITER HORIZONTAL GASKETTO FIT VERTICAL GASKET.

150

NOTE:FIRST, WETBOTTOM OF SETTINGBLOCKS WITH SOAPYWATER. ONCE GLASS IS SET,PUSH AGAINST GASKET ATSETTING BLOCK AREA.FAILURE TO DO SO MAY CAUSEDIAGONAL CRACKS TOWARDSSETTING BLOCKS DUE TO GLASSBENDING WHILE INSTALLINGGASKET(S) IN CORNERS.

FG-1133PART #: 364

FG-3220PART #: 1122

FG-3144

FG-1000-FP-2PART #: 6887SET IN PLACEWITH SEALANT.GLAZING INSTALLATION INSTRUCTIONS

GLASS SIZE7/8" OVER DAY LIGHT OPENING SETTING BLOCKSET AT 1/4 POINT OR 1/8 POINT OF HORIZONTAL LENGTHDEPENDING ON LITE SIZE. WATER DIVERTERSGLAZE FROM BOTTOM TO TOP. INSTALL WATER DIVERTERS INHORIZONTAL ABOVE, AFTER LITE BELOW IS IN POSITION. GLAZING GASKETGASKET MAY BE INSTALLED ON ONE OR BOTH SIDESSIMULTANEOUSLY. PROVIDE 3/8" ADDITIONAL GASKETFOR EACH FOOT OF DAYLIGHT OPENING TO PROVIDEADEQUATE COMPRESSION FOR THE GLAZING INFILL.NOTE: CLEAN GASKET WITH ISOPROPYL ALCOHOL PRIOR TOSEALING CORNERS.

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

28

FG-3000 SERIES ONLY,INSIDE GLAZE, SCREW SPLINE FRAME ASSEMBLY

MIN. CLEARANCE

5/16" CLEARANCE MIN. CLEARANCE

1/8" SPACE7/16"

3/8"

Most of the extrusions in this system are the same, only thesill and its anchors are different. Note that the tapes usedfor sealing the horizontals to mullions are located in a differ-ent manner.

The sill is designed so that sill anchors may be cap sealedbefore the frame is installed. The frame is installed over thethe sill with twist-in anchors. This prevents any additionalscrews from penetrating the sill and causing leaks under thesill.

Multiple units require the use of split mullions. A minimum of7/16" clearance between the jamb and sill end dam must beprovided. This will allow a minimum of 3/8" clearance tomove first unit sideways so the second unit with the sameclearance will clear the interlocking legs of the expansionmull. Adjust frame locations before running perimeter seals.Vistawall recommends using FG-2188 vinyl filler to improvethe perimeter seal.

Vistawall does not recommend the shear block or stackmethod of assembly for inside glazing.

1. Shear block joining does not provide as rigid of an assem-bly as screw spline. This makes the joint assemblies moresusceptible to sealant failure during the unit installation

process.

2. The nature of the stack system, see page 42-43, especiallyas inverted horizontal cannot be sealed with confidence forlong term performance.

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

29

INSIDE GLAZE,NON THERMAL SCREW SPLINE, FRAME ASSEMBLY

SCHNEE-MOORHEADSM-5601 1/8"X1/2" TACKY TAPE.VW PART # 4666 (OR EQUAL)NOTE: KEEP TAPE AWAY FROMSCREW SPLINES.

(TYP.)(TYP.)

2-11/16"

29/32"FS-8

(TYP.)

PART #: 10223

1-3/4"

1/4"

FG-3102

TOP 0FHORIZONTAL

SEALANTEXTERIOR ONLY

"F" (.257 DIA)DRILL THRU TYP.

1-3/4"

1-3/4"FG-3100

FG-3161

FG-3142

FG-3103

NOTE: USE RAZOR KNIFE TOTRIM EXCESS SEALANT TAPE.DO NOT PULL TAPE TO TRIM.

DJ-5 DRILL FIXTURE PART # 4562 IS ALSO AVAILABLE TO AID FABRICATION FOR SCREW SPLINE FRAME ASSEMBLY.FOR FASTER, MORE ACCURATE HOLE FABRICATION, WE RECOMMEND THE VISTAWALL EZ PUNCH FABRICATION TOOL.TM

1/4"

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

30

INSIDE GLAZE,NON THERMAL SILL FLASHING INSTALLATION

1. ANCHORS DESIGNED TO TWIST IN.2. SPACE ANCHORS MAX. 4" FROM EACH SIDE OF MULLION.3. BENT LEG ALWAYS TO EXTERIOR.4. NOTE: STAKE ANCHORS TO PREVENT HORIZONTAL MOVEMENT. ANCHORS MUST FACE EXTERIOR AS SHOWN.

INTERIOR

A SHIM UNDER FLASHINGIS THE PREFERRED METHODFOR BEST THERMAL RESULTS.

FLASHING ANCHORS MUSTBE CAP SEALED.

SEALANT

FG-3217

FG-3000-FP-4PART #: 7947

FG-3000-FP-3PART #: 7948

FG-3000-FP-11PART #: 7979

1/4" NOM.

SEAL WITH A NON-SKINNING,NON-HARDENING SEALANT.FILL BREAK IN FLASHINGAND UNDER SPLICE.

NOTE: SILL FLASHINGSHOULD BE LEVEL ANDMAKE SURE IT IS NOT TILTEDTOWARD THE INTERIOR.

SILL SPLICE

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

31

INSIDE GLAZE,NON THERMAL FRAME INSTALLATION

FG-3000-FP-3PART #: 7948

FG-3217

FG-2188PVC PROFILE

USED TO IMPROVEINSTALLATION OFBACKER ROD AND

PERIMETER SEALANT.(OPTIONAL)

FG-2122 X 4" LONG(PART SOLD IN STOCK LENGTHS.)

CLEAR HOLE(SIZE DETERMIMED BY ANCHOR.)

ANCHOR SIZE AND FREQUENCY SHOULD BE DETERMINED BY STRUCTURAL REQUIREMENTS. SILL ANCHOR FG-3000-FP-3 AND HEAD ANCHOR FG-2122 SHOULD BE LOCATEDSO THAT THE ANCHOR SCREW IS NOT MORE THAN 4" FROM EACH SIDE OF THE MULLION.

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

32

INSIDE GLAZE, NON THERMAL SILL FLASHINGINSTALLATION AND PERIMETER SEAL

APPLY SEALANT ALONG LENGTH OF SUB SILLAT AREA A.

PRIOR TO INSTALLING FRAME, APPLY SEALANTCONTINUOUSLY ALONG SILL FLASHING (B).THIS WILL PROVIDE CONTINUOUS SEALBETWEEN SILL AND SILL FLASHING.

THE QUALITY OF THE INSIDE AND OUTSIDEPERIMETER SEALS (C ) MAY BE IMPROVED BYUSING FG-2188 RIGID PVC FILLER.THE PART MAY BE USED IN FULL LENGTHS OR CUTINTO PIECES. ITS PURPOSE IS TO PROVIDESUPPORT FOR THE BACKER ROD REGARDLESSOF JOINT OR SIZE. PERIMETED SEAL (D) IS FORCOSMETIC PURPOSES AND IS OPTIONAL.

FG-3000-FP-3PART #: 7948

FG-3210

CC

C

C

E

A

D

FG-21224" LONG

(PARTS SOLD INSTOCK LENGTHS.)

THIS LEG MUST BETO EXTERIOR.

NOTE: 1/4" WEEP HOLEREQUIRED IN FLASHING (E)AT MID-LITE.

B

B

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

33

INSIDE GLAZE,NON THERMAL GLAZING PROCEDURE

MITER HORIZONTAL GASKETTO FIT VERTICAL GASKET.

150

NOTE:FIRST, WETBOTTOM OF SETTINGBLOCKS WITH SOAPYWATER. ONCE GLASS IS SET,PUSH AGAINST GASKET ATSETTING BLOCK AREA.FAILURE TO DO SO MAY CAUSEDIAGONAL CRACKS TOWARDSSETTING BLOCKS DUE TO GLASSBENDING WHILE INSTALLINGGASKET(S) IN CORNERS.

VERTICAL GASKETSRUN THRU.

HP-17PART #: 10267

FG-1133PART #: 364

FG-1000-FP-2PART #: 6887SET IN PLACEWITH SEALANT.

GLAZING INSTALLATION INSTRUCTIONS GLASS SIZE7/8" OVER DAY LIGHT OPENING SETTING BLOCKSET AT 1/4 POINT OR 1/8 POINT OF HORIZONTAL LENGTHDEPENDING ON LITE SIZE. WATER DIVERTERSGLAZE FROM BOTTOM TO TOP. INSTALL WATER DIVERTERS INHORIZONTAL ABOVE, AFTER LITE BELOW IS IN POSITION. GLAZING GASKETGASKET MAY BE INSTALLED ON ONE OR BOTH SIDESSIMULTANEOUSLY. PROVIDE 3/8" ADDITIONAL GASKETFOR EACH FOOT OF DAYLIGHT OPENING TO PROVIDEADEQUATE COMPRESSION FOR THE GLAZING INFILL.NOTE: CLEAN GASKET WITH ISOPROPYL ALCOHOL PRIOR TOSEALING CORNERS.

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

34

INSIDE GLAZE,THERMAL SLOT™ SCREW SPLINE FRAME ASSEMBLY

(TYP.)(TYP.)

2-11/16"

FS-8(TYP.)

PART #: 10223

FG-3102-S

"F" (.257 DIA)DRILL THRU TYP.

SCHNEE-MOORHEADSM-5601 1/8"X1/2" TACKY TAPE.VW PART #: 4666 (OR EQUAL)NOTE: KEEP TAPE AWAY FROMSCREW SPLINES.

TOP 0FHORIZONTAL

SEALANTEXTERIOR ONLY

FG-3161-S

FG-3142-S

FG-3103-S

1-3/4"

1-3/4"FG-3100-S

NOTE: USE RAZOR KNIFE TOTRIM EXCESS SEALANT TAPE.DO NOT PULL TAPE TO TRIM.

29/32"

DJ-5 DRILL FIXTURE PART # 4562 IS ALSO AVAILABLE TO AID FABRICATION FOR SCREW SPLINE FRAME ASSEMBLY.FOR FASTER, MORE ACCURATE HOLE FABRICATION, WE RECOMMEND THE VISTAWALL EZ PUNCH FABRICATION TOOL.TM

1-3/4"

1/4"

1/4"

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

35

INSIDE GLAZE,THERMAL SLOT™ SILL FLASHING INSTALLATION

1/4" NOM.

SEAL WITH A NON-SKINNING,NON-HARDENING SEALANT.FILL BREAK IN FLASHINGAND UNDER SPLICE.

FG-3000-FP-9/10 PART #: 7960

NOTE: SILL FLASHINGSHOULD BE LEVEL ANDMAKE SURE IT IS NOT TILTEDTOWARD THE INTERIOR.

FG-3000-FP-13PART #: 6986

A SHIM UNDER FLASHINGIS THE PREFERRED METHODFOR BEST THERMAL RESULTS.

FG-3223

FLASHING ANCHORSMUST BE CAP SEALED.

FG-3000-FP-4PART #: 7947

SEALANT

SILL SPLICE

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

36

INSIDE GLAZE,THERMAL SLOT™ FRAME INSTALLATION

FG-3000-FP-13PART #: 6986

ANCHOR SIZE AND FREQUENCY SHOULD BE DETERMINED BY STRUCTURAL REQUIREMENTS. SILL ANCHOR FG-3000-FP-13 AND HEAD ANCHOR FG-2122 SHOULD BE LOCATED SO THATTHE ANCHOR SCREW IS NOT MORE THAN 4" FROM EACH SIDE OF THE MULLION.

FG-2188PVC PROFILE

USED TO IMPROVEINSTALLATION OFBACKER ROD AND

PERIMETER SEALANT.(OPTIONAL)

FG-2122 X 4" LONG(PART SOLD IN STOCK LENGTHS.)

CLEAR HOLE(SIZE DETERMIMED BY ANCHOR.)

1. ASSEMBLY WITHOUT FLASHING IS NOT RECOMMENDED.2. DO NOT ANCHOR WALL THRU VERTICAL LEG OF FLASHING.

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

37

INSIDE GLAZE, THERMAL SLOT™ SILL FLASHINGINSTALLATION AND PERIMETER SEAL

C

C

FG-21224" LONG

(PARTS SOLD INSTOCK LENGTHS.)

APPLY SEALANT ALONG LENGTH OF SUB SILLAT POINT A.

PRIOR TO INSTALLING FRAME, APPLY SEALANTCONTINUOUSLY ALONG SILL FLASHING (B).THIS WILL PROVIDE CONTINUOUS SEALBETWEEN SILL AND SILL FLASHING.

THE QUALITY OF THE INSIDE AND OUTSIDEPERIMETER SEALS (C ) MAY BE IMPROVED BYUSING FG-2188 RIGID PVC FILLER.THE PART MAY BE USED IN FULL LENGTHS OR CUTINTO PIECES. ITS PURPOSE IS TO PROVIDESUPPORT FOR THE BACKER ROD REGARDLESSOF JOINT OR SIZE. PERIMETED SEAL (D) IS FORCOSMETIC PURPOSES AND IS OPTIONAL.

D

A

FG-3000-FP-13PART #: 6986

E

NOTE: 1/4" WEEP HOLEREQUIRED IN FLASHING (E)AT MID-LITE.

FG-3210

CC

B

B

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

38

INSIDE GLAZE,THERMAL SLOT™ GLAZING PROCEDURE

NOTE:FIRST, WETBOTTOM OF SETTINGBLOCKS WITH SOAPYWATER. ONCE GLASS IS SET,PUSH AGAINST GASKET ATSETTING BLOCK AREA.FAILURE TO DO SO MAY CAUSEDIAGONAL CRACKS TOWARDSSETTING BLOCKS DUE TO GLASSBENDING WHILE INSTALLINGGASKET(S) IN CORNERS.

VERTICAL GASKETSRUN THRU.

HP-17PART #: 10267

FG-1133PART #: 364

MITER HORIZONTAL GASKETTO FIT VERTICAL GASKET.

150

FG-1000-FP-2PART #: 6887SET IN PLACEWITH SEALANT.

*4516-1 TAPEPART #: 207

GLAZING INSTALLATION INSTRUCTIONS GLASS SIZE7/8" OVER DAY LIGHT OPENING SETTING BLOCKSET AT 1/4 POINT OR 1/8 POINT OF HORIZONTAL LENGTHDEPENDING ON LITE SIZE. WATER DIVERTERSGLAZE FROM BOTTOM TO TOP. INSTALL WATER DIVERTERS INHORIZONTAL ABOVE, AFTER LITE BELOW IS IN POSITION. GLAZING GASKETGASKET MAY BE INSTALLED ON ONE OR BOTH SIDESSIMULTANEOUSLY. PROVIDE 3/8" ADDITIONAL GASKETFOR EACH FOOT OF DAYLIGHT OPENING TO PROVIDEADEQUATE COMPRESSION FOR THE GLAZING INFILL.NOTE: CLEAN GASKET WITH ISOPROPYL ALCOHOL PRIOR TOSEALING CORNERS. *HORIZONTAL TAPECLEAN SURFACE AND APPLY TAPE FIRMLY BEFORE INSTALLINGWATER DIVERTERS.

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

39

INSIDE GLAZE,POUR & DEBRIDGE SCREW SPLINE FRAME ASSEMBLY

SCHNEE-MOORHEADSM-5601 1/8"X1/2" TACKY TAPE.VW PART # 4666 (OR EQUAL)NOTE: KEEP TAPE AWAY FROMSCREW SPLINES.

(TYP.)(TYP.)

2-11/16"

29/32"FS-8

(TYP.)

PART #: 10223

1/4"

FG-3232

"F" (.257 DIA)DRILL THRU TYP.

TOP 0FHORIZONTAL

SEALANTEXTERIOR ONLY

1-3/4"

1-3/4"FG-3231

FG-3198

FG-3197

FG-3231

NOTE: USE RAZOR KNIFE TOTRIM EXCESS SEALANT TAPE.DO NOT PULL TAPE TO TRIM.

1-3/4"

1/4"

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

40

INSIDE GLAZE,POUR & DEBRIDGE SILL FLASHING INSTALLATION

1/4" NOM.

SEAL WITH A NON-SKINNING,NON-HARDENING SEALANT.FILL BREAK IN FLASHINGAND UNDER SPLICE.

FG-3000-FP-9/10 PART #: 7960

FG-3000-FP-12PART #: 6988

A SHIM UNDER FLASHINGIS THE PREFERRED METHODFOR BEST THERMAL RESULTS.

SEALANT

FG-3223

FG-3000-FP-4PART #: 7947

FLASHING ANCHORSMUST BE CAP SEALED.

NOTE: SILL FLASHINGSHOULD BE LEVEL ANDMAKE SURE IT IS NOT TILTEDTOWARD THE INTERIOR.

SILL SPLICE

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

41

INSIDE GLAZE,POUR & DEBRIDGE FRAME INSTALLATION

ANCHOR SIZE AND FREQUENCY SHOULD BE DETERMINED BY STRUCTURAL REQUIREMENTS. SILL ANCHOR FG-3000-FP-12 AND HEAD ANCHOR FG-2122 SHOULD BE LOCATED SO THATTHE ANCHOR SCREW IS NOT MORE THAN 4" FROM EACH SIDE OF THE MULLION.

FG-3000-FP-12PART #: 6988

ANCHOR SIZEDETERMINEDBY PROJECT

FG-2122 X 4" LONG(PART SOLD IN STOCK LENGTHS.)

CLEAR HOLE(SIZE DETERMIMED BY ANCHOR.)

FG-2188PVC PROFILE

USED TO IMPROVEINSTALLATION OFBACKER ROD AND

PERIMETER SEALANT.(OPTIONAL)

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

42

SUPPLEMENTAL INSTALLATION INSTRUCTIONS FORFG-3413 SILL RECEPTOR

FG-3413 SILL RECEPTOR

ANCHOR FLASHING WITH 4" FROM EITHERSIDE OF INTERMEDIATE MULLIONS ANCHOR

SIZE AND FREQUENCY SHOULD BEDETERMINED BY STRUCTURAL REQUIREMENTS.

CAP SEAL FLASHING ANCHORS AS SHOWN.

NOTE: IF A TWO PIECE HEAD RECEPTORIS NOT USED, A 1/4” MINIMUM CLEARANCEIS REQUIRED AT THE HEAD CONDITION TOALLOW FRAME INSTALLATION.

NOTE: THE FG-3413 SILL RECEPTOR ISDESIGNED TO WITHSTAND A MAXIMUMEND REACTION OF 600 LBS.

SEAL END DAM TOSILL RECEPTOR.

SHIM UNDERSILL RECEPTOR.

FG-3413 SILL RECEPTOR

NOTE: INSTALL SILL RECEPTOR LEVEL

FG3000-FP-47

1/4" NOMINAL

SEAL WITH A NON-SKINNINGNON-HARDENING SEALANT.FILL BREAK IN FLASHINGAND UNDER SPLICE.

FG3000-FP-46

SEAL SILL RECEPTORVERTICAL SPLICE JOINT

INSTALL SPLICE SLEEVE

INSTALL SILL RECEPTOR & END DAM

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

43

SUPPLEMENTAL INSTALLATION INSTRUCTIONS FORFG-3413 SILL RECEPTOR

JUST PRIOR TO FRAME INSTALLATION, APPLYCONTINUOUS SEALANT ALONG GROOVE IN FRONTAND BACK LEGS OF SILL RECEPTOR AND AROUNDJOINT AS SHOWN. IMMEDIATELY INSTALL FRAMEINTO SILL.

SET FRONT OF FRAME INSILL RECE

1/4" WEEP HOLE REQUIREDAT MID-LITE

PTOR AND TILTBACK INTO PLACE.

SEAL SILL RECEPTOR SPLICE JOINTSUP VERTICAL LEG OF RECEPTOR ANDMARRY INTO PERIMETER SEAL.

CLEAN EXCESSSEALANT AWAY.

INTERIOR PERIMETER SEALAT SILL IS OPTIONAL AND FORCOSMETIC PURPOSES ONLY.

INSTALL FRAME & INTERIORSPLICE SEAL

INSTALL SILL RECEPTOR TO FRAME INTERIOR SEAL

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

44

INSIDE GLAZE, POUR & DEBRIDGE SILL FLASHINGINSTALLATION AND PERIMETER SEAL

FG-3210

CC

APPLY SEALANT ALONG LENGTH OF SUB SILLAT POINT A.

PRIOR TO INSTALLING FRAME, APPLY SEALANTCONTINUOUSLY ALONG SILL FLASHING (B).THIS WILL PROVIDE CONTINUOUS SEALBETWEEN SILL AND SILL FLASHING.

THE QUALITY OF THE INSIDE AND OUTSIDEPERIMETER SEALS (C ) MAY BE IMPROVED BYUSING FG-2188 RIGID PVC FILLER.THE PART MAY BE USED IN FULL LENGTHS OR CUTINTO PIECES. ITS PURPOSE IS TO PROVIDESUPPORT FOR THE BACKER ROD REGARDLESSOF JOINT OR SIZE. PERIMETED SEAL (D) IS FORCOSMETIC PURPOSES AND IS OPTIONAL.

C

C

FG-21224" LONG

(PARTS SOLD INSTOCK LENGTHS.)

B

D

A FG-3000-FP-12PART #: 6988

E

NOTE: 1/4" WEEP HOLEREQUIRED IN FLASHING (E)AT MID-LITE.

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

45

INSIDE GLAZE,POUR & DEBRIDGE GLAZING PROCEDURE

NOTE:FIRST, WETBOTTOM OF SETTINGBLOCKS WITH SOAPYWATER. ONCE GLASS IS SET,PUSH AGAINST GASKET ATSETTING BLOCK AREA.FAILURE TO DO SO MAY CAUSEDIAGONAL CRACKS TOWARDSSETTING BLOCKS DUE TO GLASSBENDING WHILE INSTALLINGGASKET(S) IN CORNERS.

VERTICAL GASKETSRUN THRU.

FG-1133PART #: 364

FG-3221PART #: 7952

MITER HORIZONTAL GASKETTO FIT VERTICAL GASKET.

150

FG-1000-FP-4/5PART #: 7971SET IN PLACEWITH SEALANT.

GLAZING INSTALLATION INSTRUCTIONS GLASS SIZE7/8" OVER DAY LIGHT OPENING SETTING BLOCKSET AT 1/4 POINT OR 1/8 POINT OF HORIZONTAL LENGTHDEPENDING ON LITE SIZE. WATER DIVERTERSGLAZE FROM BOTTOM TO TOP. INSTALL WATER DIVERTERS INHORIZONTAL ABOVE, AFTER LITE BELOW IS IN POSITION. GLAZING GASKETGASKET MAY BE INSTALLED ON ONE OR BOTH SIDESSIMULTANEOUSLY. PROVIDE 3/8" ADDITIONAL GASKETFOR EACH FOOT OF DAYLIGHT OPENING TO PROVIDEADEQUATE COMPRESSION FOR THE GLAZING INFILL.NOTE: CLEAN GASKET WITH ISOPROPYL ALCOHOL PRIOR TOSEALING CORNERS.

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

46

STACK SYSTEM,FRAME ASSEMBLY AND INSTALLATION

The assembly and sealant procedures are a part of the installation sequencebecause of the stacking method.

HEAD CAN:

Anchor screws should be within 4" of each side of the intended mullion loca-tion. Head anchors AC-121-1 should be used if the height x width x designload is 500 lbs. or more for one bay at the top of the mullion. Normally oneanchor screw at the middle of the lite or 24" O.C. is adequate for securingthe header. For unusual conditions, consult the Vistawall engineering depart-ment.

SILL CAN:

Shim can a minimum 1¼4". Anchor sill can 24" O.C. and no more than 4" oneach side of intended mullion locations. Be sure weeps are located undercenter line of mullion. Sill both sides of can.

HORIZONTAL HEAD AND SILL INSERT:

Members are cut 1¼16" less than daylight opening to allow for incrementalexpansion.

JAMB MEMBERS:

Remember all horizontals are cut 1¼16" short. Do not over shim between jamband structure.

MULLIONS

Cut mullion length outside frame dimension 1 1¼8". Install mullions by slidingtop end over anchor and rotating bottom into position.

RECOMMENDATION:

Prior to glazing, fill sill cavity with water to assure that end dams and anchorsare sealed. Then, run interior sill bead.

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

47

STACK SYSTEM ANCHORING

FG-3203

FG-3205

AC-121-1PART #: 5990

MULLION ANCHOR ROTATESINTO HEAD CAN.

1/4" WEEP HOLE AT MID-LITE.

CAP SEAL ALL HEAD ANDSILL CAN ANCHORS.

-3/4"

MULLIONHEIGHT

FRAMEDIMENSION

3/8"

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

48

STACK SYSTEM, FRAME ASSEMBLY AND INSTALLATION

1-11/16"

29/32"

2-11/16"

AC-121-1PART #: 5990TWIST IN ANCHORFITS INTO VERTICAL.

FG-3107

AC-122-1PART #: 6647TOP OF

HORIZONTAL

FG-3203

FG-3204

FG-3192

FG-2000-FP-2PART #: 7165

FG-3164

FG-3191

FG-3205

5/16"

FG-3144

FG-3144

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

49

STACK SYSTEM, FRAME SEALANT PROCEDURES

CONT. SEAL

SEAL BETWEEN SHEARBLOCK AND HORIZONTAL.

AC-121-1PART #: 5990

CONT. SEAL

CONT. SEAL

SEAL BETWEEN MULLAND HORIZONTAL.

INSIDE HORIZONTAL

NOTE: THE NATURE OF THE STACK SYSTEM REQUIRES CAREWHEN APPLYING SEALANTS AS SHOWN TO ASSUREPERFORMANCE LEVELS SHOWN IN THE TEST REPORT.

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

50

STACK SYSTEM,SEALANT PROCEDURE FOR DOOR FRAME AT FLASHING

FG-3155

FG-3156

FG-2145

LEAVE FRONT OF DOOR JAMB CLEAR OFSEALANT FOR DRAINAGE PURPOSES.

*USE SHEAR BLOCKS AS SHOWN ON PAGE 44 TO SECURE TO TUBULAR FRAME.

DOOR FRAME IS ANCHORED BY FASTENERS THROUGH THRESHOLDAND THROUGH DOOR FRAME HEADER.

DO NOT FABRICATE 2 PIECE DOOR FRAMES WITH POUR & DEBRIDGE PROFILES.

FLASHING IS BED INSEALANT AT DOOR JAMB.

RUN SEALANT ONE INCHABOVE FLASHING.

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

51

STACK SYSTEM, GLAZING PROCEDURE

NOTE:FIRST, WETBOTTOM OF SETTINGBLOCKS WITH SOAPYWATER. ONCE GLASS IS SET,PUSH AGAINST GASKET ATSETTING BLOCK AREA.FAILURE TO DO SO MAY CAUSEDIAGONAL CRACKS TOWARDSSETTING BLOCKS DUE TO GLASSBENDING WHILE INSTALLINGGASKET(S) IN CORNERS.

VERTICAL GASKETSRUN THRU.

FG-1133PART #: 364

FG-3146PART #: 6417

MITER HORIZONTAL GASKETTO FIT VERTICAL GASKET.

150

FG-1000-FP-2PART #: 6887SET IN PLACEWITH SEALANT.

GLAZING INSTALLATION INSTRUCTIONS GLASS SIZE7/8" OVER DAY LIGHT OPENING SETTING BLOCKSET AT 1/4 POINT OR 1/8 POINT OF HORIZONTAL LENGTHDEPENDING ON LITE SIZE. WATER DIVERTERSGLAZE FROM BOTTOM TO TOP. INSTALL WATER DIVERTERS INHORIZONTAL ABOVE, AFTER LITE BELOW IS IN POSITION. GLAZING GASKETGASKET MAY BE INSTALLED ON ONE OR BOTH SIDESSIMULTANEOUSLY. PROVIDE 3/8" ADDITIONAL GASKETFOR EACH FOOT OF DAYLIGHT OPENING TO PROVIDEADEQUATE COMPRESSION FOR THE GLAZING INFILL.NOTE: CLEAN GASKET WITH ISOPROPYL ALCOHOL PRIOR TOSEALING CORNERS.

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

52

ITEM DESCRIPTIONLENGTH

PCS./BOXPART NO.

24'5

FG3100S_

24'3

FG3101S_

24'10

FG3102S_

24'5

FG3103S_

24'4

FG3142S_

24'4

FG3197_

24'5

FG3161S_

24'10

FG3144_

24'10

FG3210S_

24'3

FG3107S_

24'5

FG3108S_

24'5

FG3109S_

24'4

FG3110S_24'4

FG3111S_24'8

FG3223_

Open back mullion

Heavy dutyopen back mullion

Open back filler

Open backhead/mullion

Intermediate horizontal

Alternate horizontal

Sill

Glass stop forFG-3142, FG-3161

and FG-3197

Heavy glass stopfor inside glazing

Vertical mullion

Expansion mullion/jambrequires FG-3109

Expansion mullionrequires FG-3108

900 Corner(self-mating for 180 post)

900 Corner

Sub-Sill

FG-3102-S

FG-3101-S

FG-3100-S

FG-3142-S

FG-3103-S

FG-3210

FG-3144

FG-3161-S

FG-3197

FG-3107-S

FG-3111-S

FG-3110-S

FG-3109-S

FG-3108-S

FG-3223

SERIES 3000 2" X 4-1/2" THERMAL SLOTTM

ITEM DESCRIPTIONLENGTH

PCS./BOXPART NO.

24'5

FG3231_

24'10

FG3232_

24'5

FG3103S_

24'10

FG3102S_

24'4

FG3197_

24'5

FG3198_

24'10

FG3144_

24'10

FG3210_

24'8

FG3223_

24'2

FG3320_

24'5

FG3328_

24'5

FG3329_

Open backhead/jamb/mullion

Open back filler

Thermal slot open backhead/jamb/mullion

Thermal slotopen back filler

Intermediate horizontal

Sill

Glass stop forFG-3197, FG-3198

and FG-3320

Heavy glass stopfor inside glazing

Sub-sill

4-13/16" High sidelightbase use FG-3144 stop

Expansion mullionrequires FG-3329

Expansion mullionrequires FG-3328

FG-3232

FG-3231

FG-3103-S

FG-3144

FG-3198

FG-3197

FG-3102-S

FG-3223

FG-3210

FG-3329

FG-3328

FG-3320

Heavy VerticalMullion

24'2

FG3313_FG-3313

SERIES 3000 2" X 4-1/2" THERMAL CENTER SET

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

53

ITEM DESCRIPTIONLENGTH

PCS./BOXPART NO.

24'5

FG3100_

24'3

FG3101_

24'10

FG3102_

24'5

FG3103_

24'4

FG3142_

24'5

FG3161_

24'10

FG3164_

24'10

FG3144_

24'5

FG3135_

24'5

FG3108_

24'5

FG3109_

24'5

FG3180_

24'5

FG3181_24'10

FG3210_

Open back mullion

Heavy dutyopen back mullion

Open back filler

Open backhead/mullion

Intermediate horizontal

Sill(Use FG-3164 filler

for horizontal)

Open back filler

shallow pocket

maximum glass bite=3/8"

Glass stop for FG-3142and FG-3161

Open back mullion

shallow pocket

maximum glass bite=3/8"

Expansion mullion/jambrequires FG-3109

Expansion mullionrequires FG-3108

Adjustable mullion20 to 100

mates with FG-3181Adjustable mullion

20 to 100

mates with FG-3180

Heavy glass stop forinside glazing

FG-3142

FG-3102

FG-3103

FG-3101

FG-3100

FG-3144

FG-3164

FG-3161

FG-3181

FG-3180

FG-3109

FG-3108

FG-3135

FG-3210

SERIES 3000 2" X 4-1/2" SCREW SPLINE NON-SLOT

ITEM DESCRIPTIONLENGTH

PCS./BOXPART NO.

24'10

FG3164_

24'10

FG3144_

24'5

FG3100_

24'3

FG3107_

24'5

FG3203_

24'5

FG3204_

24'5

FG3191_

24'5

FG3205_

24'5

FG3192_

Horizontal filler

Stop forFG-3191 and FG-3192

Jamb

Mullion

Head receptor

Head insert

Sill Insert

Sill receptor

Open back horizontal

(Use AC-122-1)

FG-3107

FG-3203

FG-3100

FG-3164

FG-3192

FG-3205

FG-3191

FG-3204

FG-3144

SERIES 3000 2" X 4-1/2" STACK SYSTEM NON-SLOT

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

54

ITEM DESCRIPTIONLENGTH

PCS./BOXPART NO.

24'

5

FG2122_

24'

4

FG3110_

24'

4

FG3111_

24'

4

FG3201_

24'

4

FG2112_

24'

4

FG2138_

24'

10

FG3141_

24'

5

MO243_

24'

5

MO244_

24'

5

FG2139_

Open back flat filler

900 Corner (selfmating for 180 post)

900 Split corner

900 Corner w/FG-21123-Way post w/FG-3111

Corner postself mating

1350 /450 Corneruse FG-3141 orFG-3102 filler

Deep pocket filler for

FG-2138

4-1/2" Head receptorback

V-11 weatheringnot included

Head receptor face

V-11 weathering

not included

Head receptorV-11 weathering

not included

FG-3110

FG-3111

FG-2122

FG-2138

FG-2112

FG-3201

MO-244

MO-243

FG-3141

FG-2139

SERIES 3000 2" X 4-1/2"AUXILIARY EXTRUSIONS NON-SLOT

ITEM DESCRIPTIONLENGTH

PCS./BOXPART NO.

24'10

FG2169_

24'8

FG3217_

15'1

923

24'24

FG3126_

24'12

FG3194_

24'12

FG3236_

24'12

FG3237_

Sub-Sill(high back)

Sub-Sill(inside glazed)

Steel reinforcementfor FG-3135 and

FG-3164 only

Snap-in pocket filler

Pocket reducer for1/4" glass

Pocket reducer for7/16" glass

Pocket reducer for

5/8" glass

RS-1

FG-3126

FG-3194

FG-2169

FG-3217

FG-3237

FG-3236

SERIES 3000 2" X 4-1/2"AUXILIARY EXTRUSIONS NON-SLOT

ITEM DESCRIPTIONLENGTH

PCS./BOXPART NO.

24'3

FG3155_

24'3

FG3168_

24'5

FG3156_

Tubular door jamb

Tubular doubledoor jamb

Open back door jamb

FG-3156

FG-3168

FG-3155

SERIES 3000 2" X 4-1/2" DOOR FRAME COMPONENTSNON-SLOT/NON-THERMAL

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

55

SERIES 3000 2" X 4-1/2" DOOR FRAME COMPONENTSNON-SLOT/NON-THERMAL

SERIES 3000 2" X 4-1/2" DOOR FRAME COMPONENTSNON-SLOT/NON-THERMAL

ITEM DESCRIPTIONLENGTH

PCS./BOXPART NO.

24'12

FG3157_

24'12

FG3158_

24'3

FG3160_

24'3

FG3163_

24'5

FG3196_

24'10

FG1129_

24'10

FG1184_

21'-5"18

FG2145_215

Door transom glazingadaptor

Door transom glazingadaptor stop

Tube door headerfor OHCC

Door header for openback frames

Door headerfor OHCC

Snap-in filler forFG-3196 header

Snap-in filler forFG-3196 headerwith weathering

1/2" X 1-1/16"Snap-in door stopwith weathering

FG-3196

FG-3163

FG-3160

FG-3158

FG-3157

FG-2145

FG-1184

FG-1129

ITEM DESCRIPTIONLENGTH

PCS./BOXPART NO.

21'-5"18

FG2120_21524'18

DS1_24'12

DS108__

24'10

DS104_

21'-5"24

FG1123_215

24'3

FG3287_

24'12

FG3324_24'12

FG3325_

1/2" X 1-5/8"Snap-in door stopwith weathering

1/2" X 1-5/8" Door stopwith weathering(use SC-1 clip)

3/4" X 1-5/8" Door stopwith weathering(use SC-1 clip)

1 3/16" X 2" Door stopwith weathering

(use FS-201 screw)

Slide-in pocket filler

Door frame jambfor front & back set

Transom glazing adaptormates with FG-3287

Transom glazing adaptorstop mates with FG-3224

FG-1123

DS-104

DS-108

DS-1

FG-2120

FG-3325

FG-3324

FG-3287

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

56

ITEM DESCRIPTION PCS.BOX

300'

300'

300'

300'

300'

500'

250'

100'

100'

100

100

100

100

100'

ITEM DESCRIPTION PCS.BOX

Setting block forFG-3157,

FG-3293, FG-3294

Tape water diverterfor slotted system

Water diverter forcenter set outside

glazed and all frontset and back/setWater diverter for

center setinside glazed

Splice forFG-2169

Splice forFG-3127

Splice forFG-3223

End damfor FG-2169

End damfor FG-3217/

FG-3223

Joint sealant tape1/8" X 1/2"

Jamb support foranchors, slotted sys-

tem only

Vinyl filler for caulkstop 12'

Vinyl pocket filler forwindow applications

12'

200

50

50

100

10

10

10

20

20

30'

20

10

10

V-11

FL-66

FG-3129

FG-1134

FG-1133

WP-084

D-125

CW-998

WP-083

HP-92

FG-3221

FG-3278

FG-3220

FG-3146

FG-2000-FP-7

FG-1000-FP-4/5

FG-1000-FP-2

4516-1

HP-17

SM-5601

FG-3000-FP-4

FG-2000-FP-4

FG-3000-FP-9/10

FG-3000-FP-11

FG-3218

FG-2188

FG-3046

FG3000-FP-30

Butt GlazeHorizontal

Shear BlockButt GlazeHorizontal

Water Diverter50

20

FG3000-FP-33

Butt GlazeSpacer

Heavy gasket

5/8"Glazing gasket

Light gasket

Spacer gasket for slot/non-thermal expansion mullion

& head receptors

Spacer gasket forthermal expansion

mullion

Weathering gasketfor airtight applica-

tions

Weathering fordoorstops

Weathering for dou-ble acting headers

Setting blockFG-3142 and 3161

Setting blockFG-3197, 3198 and

FG-3280

Setting block forfront & back set high

sidelite base

Inside glaze settingblock for FG-3197

Setting block forFG-3155 and 3163

stacked

250'SHP-30066

1"Glazing gasket

SERIES 3000 ACCESSORIES SERIES 3000 ACCESSORIES

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

57

ITEM DESCRIPTION PCS.BOX

Shear block forFG-3142 and FG-3161

(screws included)

Shear block forFG-3155 door header

Shear block forFG-3160 and FG-3196

door header(screws included)

Shear block forFG-3280

Shear block forFG-3291/3293/3294

Shear block forFG-3296

Shear block forFG-3103 header(screws included)Shear block for

FG-3192 horizontal(screws included)

Mullion anchor athead for FG-3190

and FG-3203

Anchor forFG-3161-S sill

Sill anchor forFG-3161

Sill anchorfor FG-3217inside glazed

Sill anchorfor FG-3223thermal slot

outside glazed slottedSill anchor for

FG-3223 thermalslot-inside glazed

20

20

20

20

20

20

20

20

20

20

20

20

20

20

ITEM DESCRIPTION PCS.BOX

Sill anchorfor FG-3223

thermal inside glazedSill anchor

for FG-3223outside glazed

Sill anchorfor FG-3280

Sill anchorisolator for

back set only

Sill anchorfor FG-3332sidelite base

Spring clip forDS-1 & DS-108

#14 X 1" H.H.S.T.S.Assembly screw

#14 X 1-3/4"P.F.H.W.S.

anchors FG thrupocket

#14 X 1"plastic plug

3/16" dia. X 7/16"Drive rivet anchors

SC-1 clip

#10 X 3/4" P.P.H.attaches sill to

sill anchorDrill fixture for screw

spline assemblyFG-3103, 3142, 3161Drill fixture for shear

block assemblyAC-119-1 & AC-108-

20

20

20

20

20

100

100

100

100

100

200

200

200

1

1

#10 X 2" PFHattachesDS-104

FS-201CLR.

FS-201BRZ.

FG-3000-FP-30

FG-3000-FP-29 FG-3000-FP-28

FG-3000-FP-27AC-107-1

FG-3000-FP-15FG-3100-FP-1

FG-3000-FP-12AC-119-1

FG-3000-FP-32

AC-108-1

FS-15

FS-12

FG-3100-FP-2

AC-121-1

AC-122-1

FG-3000-FP-31

FS-10

FS-8

SC-1

DJ-6

DJ-5

FG-3000-FP-13

FG-3000-FP-14

FG-3000-FP-3

FG-2000-FP-3 FS-201

FS-6

SERIES 3000 ACCESSORIES SERIES 3000 ACCESSORIES

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

58

F L U S H G L A Z ES E R I E S 3 0 0 0M U L T I P L A N E

I N S T A L L A T I O NM A N U A L

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

59

* FG3000-FP-27 PART#: 829

REFERENCE FG-3000 INSTALLATIONMANUAL FOR INSTRUCTIONS ONPOUR & DEBRIDGE TYPICAL SYSTEMINSTALLATION AND SEALANT DETAILS.

FG3000-FP-28PART#: 822

FG-3223

FG3000-FP-27PART#: 829

A SHIM UNDER FLASHINGIS THE PERFECT METHODFOR BEST THERMAL RESULTS.

* ANCHOR NOTE: FG3000-FP-27 ANCHOR USED TYPICAL AT ALL MULTI-PLANE FRONT AND BACK SET INSTALLATIONS. FG3000-FP-28 ISOLATOR TO BE USED ONLY AT BACK SET INSTALLATIONS.

FLASHING ANCHORSMUST BE CAP SEALED.

FG3000-FP-4PART#: 7947

POUR & DEBRIDGE SILL FLASHINGINSTALLATION FOR MULTIPLANE

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

60

SCHNEE-MOREHEADSM-5601 1/8" X 1/2" TACKY TAPE.VW PART#: 4666 (OR EQUAL)NOTE: KEEP TAPE AWAY FROMSCREW SPLINES.

FG-3296

FG-3295

FG-3294

HP-17

FG-3284FG-3295

FG-3280

FG-3220

NOTE: USE RAZOR KNIFE TOTRIM EXCESS SEALANT TAPE.DO NOT PULL TAPE TO TRIM.

FG-3283

FG-3284

1 3/4"

TOP OFHORIZONTAL

SEALANTEXTERIOR ONLY

"F" (.257 DIA)DRILL THRU TYP.

5/8"(TYP)

11/16"(TYP)

1 3/4"

(TYP)

1 1/4"

FS-8 (TYP)

PART #: 10223

(TYP)

1 1/4"

1/4"

OUTSIDE GLAZED,FRONT SET SCREW SPLINE FRAME ASSEMBLY

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

61

SCHNEE-MOREHEADSM-5601 1/8" X 1/2" TACKY TAPE.VW PART#: 4666 (OR EQUAL)NOTE: KEEP TAPE AWAY FROMSCREW SPLINES.

FS-8 (TYP)PART#: 10223

#11 (.191 )CLEAR HOLE

#11 (.191 )DRILL THRU TYP.

FG-3296

FG-3294

FG-3280

HP-17

FG-3220

FS-6 (TYP)

TYP. #25TAP HOLE

FG3000-FP-29

FG3000-FP-30

SEALANTEXTERIOR ONLY

TOP OFHORIZONTAL

FG-3283

FG-3284

1 3/8"

5/8"

1 3/8"

5/8"(TYP)

NOTE: USE RAZOR KNIFE TOTRIM EXCESS SEALANT TAPE.DO NOT PULL TAPE TO TRIM.

11/16"(TYP)

(TYP)

1 1/4"

(TYP)

1 1/4"

FG3000-FP-31

OUTSIDE GLAZED,FRONT SET SHEARBLOCK FRAME ASSEMBLY

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

62

SCHNEE-MOREHEADSM-5601 1/8" X 1/2" TACKY TAPE.VW PART#: 4666 (OR EQUAL)NOTE: KEEP TAPE AWAY FROMSCREW SPLINES.

FG-3291

FG-329O

FG-3293

HP-17

FG-3290

FG-3280

FG-3220

NOTE: USE RAZOR KNIFE TOTRIM EXCESS SEALANT TAPE.DO NOT PULL TAPE TO TRIM.

FG-3283

FG-3284

1 3/4"

TOP OFHORIZONTAL

SEALANTEXTERIOR ONLY

"F" (.257 DIA)DRILL THRU TYP.

5/8"(TYP)

11/16"(TYP)

5/8"

(TYP)

1 1/4"

FS-8 (TYP)

PART #: 10223

(TYP)

1 1/4"

1/4"

OUTSIDE GLAZED,BACK SET SCREW SPLINE FRAME ASSEMBLY

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

63

SCHNEE-MOREHEADSM-5601 1/8" X 1/2" TACKY TAPE.VW PART#: 4666 (OR EQUAL)NOTE: KEEP TAPE AWAY FROMSCREW SPLINES.

FS-8 (TYP)PART#: 10223

#11 (.191 )CLEAR HOLE

#11 (.191 )DRILL THRU TYP.

FG-3291

FG-3293

HP-17

FG-3280

FG-3220

FS-6 (TYP)

FS-6 (TYP)

TYP. #25TAP HOLE

FG3000-FP-29

FG3000-FP-30

FG3000-FP-30SEALANT

EXTERIOR ONLY

TOP OFHORIZONTAL

FG-3283

FG-3284

1 3/8"

5/8"

1/4"

5/8"(TYP)

NOTE: USE RAZOR KNIFE TOTRIM EXCESS SEALANT TAPE.DO NOT PULL TAPE TO TRIM.

11/16"(TYP)

(TYP)

1 1/4"

(TYP)

1 1/4"

OUTSIDE GLAZED,BACK SET SHEARBLOCK FRAME ASSEMBLY

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

64

SCHNEE-MOREHEADSM-5601 1/8" X 1/2" TACKY TAPE.VW PART#: 4666 (OR EQUAL)NOTE: KEEP TAPE AWAY FROMSCREW SPLINES.

FG-3291

FG-3290

FG-3293

HP-17

FG-3290

FG-3280

FG-3220

NOTE: USE RAZOR KNIFE TOTRIM EXCESS SEALANT TAPE.DO NOT PULL TAPE TO TRIM.

FG-3283

FG-3284

1 3/4"

TOP OFHORIZONTAL

SEALANTEXTERIOR ONLY

"F" (.257 DIA)DRILL THRU TYP.

5/8"(TYP)

11/16"(TYP)

5/8"

(TYP)

1 1/4"

FS-8 (TYP)

PART #: 10223(TYP)

1 1/4"

1/4"

INSIDE GLAZED,FRONT SET SCREW SPLINE FRAME ASSEMBLY

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

65

SCHNEE-MOREHEADSM-5601 1/8" X 1/2" TACKY TAPE.VW PART#: 4666 (OR EQUAL)NOTE: KEEP TAPE AWAY FROMSCREW SPLINES.

FS-8 (TYP)PART#: 10223

FG3000-FP-30

#11 (.191 )DRILL THRU TYP.

#11 (.191 )DRILL THRU TYP.

FG-3291

HP-17

FG-3280

FG-3220

FS-6 (TYP)

TYP. #25TAP HOLE

FG3000-FP-30

FG3000-FP-29

TOP OFHORIZONTAL

SEALANTEXTERIOR ONLY

FG-3283

FG-3284

1 3/8"

5/8"

1/4"

5/8"(TYP)

NOTE: USE RAZOR KNIFE TOTRIM EXCESS SEALANT TAPE.DO NOT PULL TAPE TO TRIM.

11/16"(TYP)(TYP)

1 1/4"

(TYP)

1 1/4"

INSIDE GLAZED,FRONT SET SHEARBLOCK FRAME ASSEMBLY

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

66

SCHNEE-MOREHEADSM-5601 1/8" X 1/2" TACKY TAPE.VW PART#: 4666 (OR EQUAL)NOTE: KEEP TAPE AWAY FROMSCREW SPLINES.

FG-3296

FG-3295

FG-3294HP-17

FG-3284

FG-3295

FG-3280FG-3220

NOTE: USE RAZOR KNIFE TOTRIM EXCESS SEALANT TAPE.DO NOT PULL TAPE TO TRIM.

FG-3283

FG-3284

1 3/4"

TOP OFHORIZONTAL

SEALANTEXTERIOR ONLY

"F" (.257 DIA)DRILL THRU TYP.

5/8"(TYP)

11/16"(TYP)

1 3/4"

(TYP)

1 1/4"

FS-8 (TYP)

PART #: 10223

(TYP)

1 1/4"

1/4"

INSIDE GLAZED,BACK SET SCREW SPLINE FRAME ASSEMBLY

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

67

SCHNEE-MOREHEADSM-5601 1/8" X 1/2" TACKY TAPE.VW PART#: 4666 (OR EQUAL)NOTE: KEEP TAPE AWAY FROMSCREW SPLINES.

FG-3296

FG-3295

HP-17

FG-6 (TYP)

FG-3280

FG-3220

NOTE: USE RAZOR KNIFE TOTRIM EXCESS SEALANT TAPE.DO NOT PULL TAPE TO TRIM.

FG-3283

FG3000-FP-29

FG3000-FP-30

FG3000-FP-31

FG-3284

1 3/8"

TOP OFHORIZONTAL

SEALANTEXTERIOR ONLY

5/8"(TYP)

11/16"(TYP) 1 3/8"

TYP. #25TAP HOLE

FS-8 (TYP)PART #: 10223

(TYP)

1 1/4"

(TYP)

1 1/4"

5/8"

#11 (.191 )CLEAR HOLE

#11 (.191 )CLEAR HOLE

INSIDE GLAZED,BACK SET SHEARBLOCK FRAME ASSEMBLY

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

68

ITEM DESCRIPTIONLENGTH

PCS./BOXPART NO.

24'5

FG3231_

24'10

FG3232_

24'5

FG3103S_

24'10

FG3102S_

24'4

FG3197_

24'5

FG3198_

24'10

FG3144_

24'10

FG3210_

24'8

FG3223_

24'2

FG3320_

24'5

FG3328_

24'5

FG3329_

Open backhead/jamb/mullion

Open back filler

Thermal slot open backhead/jamb/mullion

Thermal slotopen back filler

Intermediate horizontal

Sill

Glass stop forFG-3197, FG-3198

and FG-3320

Heavy glass stopfor inside glazing

Sub-sill

4-13/16" High sidelightbase use FG-3144 stop

Expansion mullionrequires FG-3329

Expansion mullionrequires FG-3328

FG-3232

FG-3231

FG-3103-S

FG-3144

FG-3198

FG-3197

FG-3102-S

FG-3223

FG-3210

FG-3329

FG-3328

FG-3320

Heavy VerticalMullion

24'2

FG3313_FG-3313

SERIES 3000 2" X 4-1/2" THERMAL CENTER SET

ITEM DESCRIPTIONLENGTH

PCS./BOXPART NO.

24'5

FG3280_

24'5

FG3283_

24'5

FG3297_

24'10

FG3284_

24'5

FG3296_

24'4

FG3294_

24'10

FG3295_

24'5

FG3291_

24'4

FG3293_

24'8

FG3290_

24'8

FG3223_

24'2

FG3331_

24'2

FG3332_

24'5

FG3326_

24'5

FG3327_

Open backjamb & sill

Open backmullion

Open backheavy mullion

Open back filler(mullion & horizontal)

Outside glaze head

Outside glazehorizontal

Face stop forFG-3296/FG-3294

Inside glaze head

Inside glaze horizontal

Glass stop forFG-3291, FG-3293

Sub-sill

4-5/8"side light base

mates with FG-3332

4-5/8"side light base

mates with FG-3331

Expansion mullionrequires FG-3327

Expansion mullionrequires FG-3326

FG-3280

FG-3284

FG-3297

FG-3283

FG-3294

FG-3296

FG-3223

FG-3293

FG-3290

FG-3291

FG-3295

FG-3327

FG-3326

FG-3332

FG-3331

SERIES 3000 2" X 4-1/2" THERMAL FRONT SET

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

69

ITEM DESCRIPTIONLENGTH

PCS./BOXPART NO.

24'5

FG3280_

24'5

FG3283_

24'5

FG3297_

24'10

FG3284_

24'5

FG3291_

24'4

FG3293_

24'8

FG3290_

24'5

FG3296_

24'4

FG3294_

24'10

FG3295_

24'8

FG3223_

24'2

FG3331_

24'2

FG3332_

24'5

FG3326_

24'5

FG3327_

Open backjamb & sill

Open backmullion

Open backheavy mullion

Open back filler(mullion & horizontal)

Outside glaze head

Outside glazehorizontal

Glass stop forFG-3291/FG-3293

Inside glaze head

Inside glaze horizontal

Face stop forFG-3296, FG-3294

Sub-sill

4-5/8"side light base

mates with FG-3332

4-5/8"side light base

mates with FG-3331

Expansion mullionrequires FG-3327

Expansion mullionrequires FG-3326

FG-3283

FG-3293

FG-3291

FG-3284

FG-3297

FG-3223

FG-3295

FG-3294

FG-3296

FG-3290

FG-3327

FG-3326

FG-3332

FG-3331

FG-3280

SERIES 3000 2" X 4-1/2" THERMAL BACK SET

ITEM DESCRIPTIONLENGTH

PCS./BOXPART NO.

24'5

FG3285_

24'5

FG3285_

24'5

FG3285_

24'5

FG3285_

24'8

FG3286_

24'5

FG3281_

24'5

FG3281_

24'8

FG3282_

Open backmullion center set

to back set

Open backmullion center set

to front set

Open backmullion front set

to center set

Open backmullion back set

to center set

Open backfiller for FG-3285

Open backmullion for front set

to back set

Open backmullion for back set

to front set

Open backfiller for FG-3281

FG-3286

FG-3285

FG-3285

FG-3285

FG-3285

FG-3282

FG-3281

FG-3281

SERIES 3000 2" X 4-1/2"THERMAL MULTIPLANE VERTICALS

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

70

ITEM DESCRIPTIONLENGTH

PCS./BOXPART NO.

24'5

MO678_

24'10

MO679_

24'4

FG3214_

24'4

FG3215_

24'4

FG3301_

24'4

FG3302_

24'4

FG3306_

24'4

FG3307_

24'4

FG3322_

24'4

FG3321_

24'4

FG3300_

24'4

FG3303_

24'4

FG3304_

24'4

FG3305_

Receptor

Receptor face

Center set900 corner

Center set900 corner

(self-mating 1800)

Front set outside 900

back set inside 900 corner

900 Corner(mates w/FG-3301)

Front set inside 900

back set outside 900 corner

(req. 2 each corner)

900 Corner matesw/FG-3306

(req. 2 each corner)

Center set 1350

corner

Center set 1350

corner filler(2 per corner)

Front set 1350 outside

back set 1350 inside corner

(2 per corner)

Front set 1350 insideback set 1350

outside corner

1350 corner matesw/FG-3303

1350 filler forFG-3303/3304

MO-678

FG-3302

FG-3301

FG-3215

FG-3214

MO-679

FG-3306

FG-3307

FG-3303

FG-3300

FG-3321

3322

FG-3305

FG-3304

SERIES 3000 2" X 4-1/2"THERMAL AUXILIARY EXTRUSIONS

ITEM DESCRIPTION PCS.BOX

300'

300'

300'

300'

300'

500'

250'

100'

100'

100

100

100

100

100'

V-11

FL-66

FG-3129

FG-1134

FG-1133

WP-084

D-125

CW-998

WP-083

HP-92

FG-3221

FG-3278

FG-3220

FG-3146

Butt GlazeSpacer

Heavy gasket

5/8"Glazing gasket

Light gasket

Spacer gasket for slot/non-thermal expansion mullion

& head receptors

Spacer gasket forthermal expansion

mullion

Weathering gasketfor airtight applica-

tions

Weathering fordoorstops

Weathering for dou-ble acting headers

Setting blockFG-3142 and 3161

Setting blockFG-3197, 3198 and

FG-3280

Setting block forfront & back set high

sidelite base

Inside glaze settingblock for FG-3197

Setting block forFG-3155 and 3163

stacked

250'SHP-30066

1"Glazing gasket

SERIES 3000 ACCESSORIES

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

71

ITEM DESCRIPTION PCS.BOX

Setting block forFG-3157,

FG-3293, FG-3294

Tape water diverterfor slotted system

Water diverter forcenter set outside

glazed and all frontset and back/setWater diverter for

center setinside glazed

Splice forFG-2169

Splice forFG-3127

Splice forFG-3223

End damfor FG-2169

End damfor FG-3217/

FG-3223

Joint sealant tape1/8" X 1/2"

Jamb support foranchors, slotted sys-

tem only

Vinyl filler for caulkstop 12'

Vinyl pocket filler forwindow applications

12'

200

50

50

100

10

10

10

20

20

30'

20

10

10

FG-2000-FP-7

FG-1000-FP-4/5

FG-1000-FP-2

4516-1

HP-17

SM-5601

FG-3000-FP-4

FG-2000-FP-4

FG-3000-FP-9/10

FG-3000-FP-11

FG-3218

FG-2188

FG-3046

FG3000-FP-30

Butt GlazeHorizontal

Shear BlockButt GlazeHorizontal

Water Diverter50

20

FG3000-FP-33

SERIES 3000 ACCESSORIES

ITEM DESCRIPTION PCS.BOX

Shear block forFG-3142 and FG-3161

(screws included)

Shear block forFG-3155 door header

Shear block forFG-3160 and FG-3196

door header(screws included)

Shear block forFG-3280

Shear block forFG-3291/3293/3294

Shear block forFG-3296

Shear block forFG-3103 header(screws included)Shear block for

FG-3192 horizontal(screws included)

Mullion anchor athead for FG-3190

and FG-3203

Anchor forFG-3161-S sill

Sill anchor forFG-3161

Sill anchorfor FG-3217inside glazed

Sill anchorfor FG-3223thermal slot

outside glazed slottedSill anchor for

FG-3223 thermalslot-inside glazed

20

20

20

20

20

20

20

20

20

20

20

20

20

20

FG-3000-FP-30

FG-3000-FP-29

AC-107-1

FG-3100-FP-1

AC-119-1

AC-108-1

FG-3100-FP-2

AC-121-1

AC-122-1

FG-3000-FP-31

FG-3000-FP-13

FG-3000-FP-14

FG-3000-FP-3

FG-2000-FP-3

SERIES 3000 ACCESSORIES

January 2005

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

72

ITEM DESCRIPTION PCS.BOX

Sill anchorfor FG-3223

thermal inside glazedSill anchor

for FG-3223outside glazed

Sill anchorfor FG-3280

Sill anchorisolator for

back set only

Sill anchorfor FG-3332sidelite base

Spring clip forDS-1 & DS-108

#14 X 1" H.H.S.T.S.Assembly screw

#14 X 1-3/4"P.F.H.W.S.

anchors FG thrupocket

#14 X 1"plastic plug

3/16" dia. X 7/16"Drive rivet anchors

SC-1 clip

#10 X 3/4" P.P.H.attaches sill to

sill anchorDrill fixture for screw

spline assemblyFG-3103, 3142, 3161Drill fixture for shear

block assemblyAC-119-1 & AC-108-

20

20

20

20

20

100

100

100

100

100

200

200

200

1

1

#10 X 2" PFHattachesDS-104

FS-201CLR.

FS-201BRZ.

FG-3000-FP-28

FG-3000-FP-27

FG-3000-FP-15

FG-3000-FP-12

FG-3000-FP-32

FS-15

FS-12

FS-10

FS-8

SC-1

DJ-6

DJ-5

FS-201

FS-6

SERIES 3000 ACCESSORIESGLASS SIZE ADAPTOR GASKETS

1/4" FG-3194 FG-1133 BOTH SIDES

5/16" FG-3236 FL-66 BOTH SIDES

3/8" FG-3236 FG-1133 & FL-66

7/16" FG-3236 FG-1133 BOTH SIDES

1/2" FG-3237 FL-66 BOTH SIDES

9/16" FG-3237 FG-1133 & FL-66

5/8" FG-3237 FG-1133 BOTH SIDES

11/16" FG-3237 FG-1133 & FG-1134

3/4" FG-3237 FL-1134 BOTH SIDES

13/16" N/A NOT AVAILABLE

7/8" NONE FG-66 BOTH SIDES

15/16" NONE FL-1133 & FL-66

1" NONE FG-1133 BOTH SIDES

1-1/16" NONE FG-1133 & FG-1134

1-1/8" NONE FG-1134 BOTH SIDES

INFILL THICKNESS OPTIONS

January 2005

AC-119-1 PART #: 6295

AC-119-1 PART #: 6295

*AC-108-1 PART #: 6533

FG-3103

FG-3142

FG-3161

FS-7FS-6

FS-6

*AC-119-1 PART #: 6295

*AC-119-1 PART #: 6295

TYP. #25TAP HOLE

ROLLPIN

*AC-108-1 PART #: 653

11/32"

1-3/4"

1-1/4"

1-1/4"

11/32"

7/16"

7/16"

ROLLPIN

TYP.

2"TYP.

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L

Phone: 972-551-6100Fax: 972-551-6264January 2005