FloTHERM 10 1 New Functionality - 易富迪科技 · PDF fileFloTHERM New Functionality,...
Transcript of FloTHERM 10 1 New Functionality - 易富迪科技 · PDF fileFloTHERM New Functionality,...
FloTHERM® New Functionality
Software Version fth10.1
July 2014
2014 Mentor Graphics Corporation All rights reserved.
This document contains information that is proprietary to Mentor Graphics Corporation. The original recipient of this document may duplicate this document in whole or in part for internal business purposes only, provided that this entire notice appears in all copies. In duplicating any part of this document, the recipient agrees to make every reasonable effort to prevent the unauthorized use and distribution of the proprietary information.
This document is for information and instruction purposes. Mentor Graphics reserves the right to make changes in specifications and other information contained in this publication without prior notice, and the reader should, in all cases, consult Mentor Graphics to determine whether any changes have been made.
The terms and conditions governing the sale and licensing of Mentor Graphics products are set forth in written agreements between Mentor Graphics and its customers. No representation or other affirmation of fact contained in this publication shall be deemed to be a warranty or give rise to any liability of Mentor Graphics whatsoever.
MENTOR GRAPHICS MAKES NO WARRANTY OF ANY KIND WITH REGARD TO THIS MATERIAL INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
MENTOR GRAPHICS SHALL NOT BE LIABLE FOR ANY INCIDENTAL, INDIRECT, SPECIAL, OR CONSEQUENTIAL DAMAGES WHATSOEVER (INCLUDING BUT NOT LIMITED TO LOST PROFITS) ARISING OUT OF OR RELATED TO THIS PUBLICATION OR THE INFORMATION CONTAINED IN IT, EVEN IF MENTOR GRAPHICS CORPORATION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
RESTRICTED RIGHTS LEGEND 03/97
U.S. Government Restricted Rights. The SOFTWARE and documentation have been developed entirely at private expense and are commercial computer software provided with restricted rights. Use, duplication or disclosure by the U.S. Government or a U.S. Government subcontractor is subject to the restrictions set forth in the license agreement provided with the software pursuant to DFARS 227.7202- 3(a) or as set forth in subparagraph (c)(1) and (2) of the Commercial Computer Software - Restricted Rights clause at FAR 52.227-19, as applicable.
Contractor/manufacturer is: Mentor Graphics Corporation
8005 S.W. Boeckman Road, Wilsonville, Oregon 97070-7777. Telephone: 503.685.7000
Toll-Free Telephone: 800.592.2210 Website: www.mentor.com
SupportNet: supportnet.mentor.com/ Send Feedback on Documentation: supportnet.mentor.com/user/feedback_form.cfm
TRADEMARKS: The trademarks, logos and service marks ("Marks") used herein are the property of Mentor Graphics Corporation or other third parties. No one is permitted to use these Marks without the prior written consent of Mentor Graphics or the respective third-party owner. The use herein of a third- party Mark is not an attempt to indicate Mentor Graphics as a source of a product, but is intended to indicate a product from, or associated with, a particular third party. A current list of Mentor Graphics’ trademarks may be viewed at: www.mentor.com/terms_conditions/trademarks.cfm.
End-User License Agreement: You can print a copy of the End-User License Agreement from: www.mentor.com/terms_conditions/enduser.cfm.
FloTHERM New Functionality, fth10.1 1 June 2014
Detailed Change Description This document provides an overview of the changes available in FloTHERM fth10.1.
Combined Project Manager and Drawing Board Application Windows
Ref. Title Description
1.1 Undockable Drawing
Board graphics area
The Drawing Board area may be optionally undocked from (and re-
docked with) the Project Manager node tree via the [Window] menu or
toolbar icon.
The undocked Drawing Board can then be moved over to a second
monitor display.
1.2 Stored Number of
Drawing Board
Views
The last number of Drawing Board views used in a FloTHERM session
is now saved and restored when restarting FloTHERM.
2 FloTHERM New Functionality, fth10.1 June 2014
Ref. Title Description
1.3 Project Manager IDF
Preferences
The default and filtering settings used when using the Project Manager
IDF import feature are available in the User Preferences dialog. These
are shown only if the ‘Configure IDF’ box is checked.
Note that these settings only apply to Project Manager IDF import (via
the right-click assembly import). IDF import through FloEDA Bridge
is handled seperately.
FloTHERM New Functionality, fth10.1 3 June 2014
Ref. Title Description
1.4 Display of Axis on
Selected Objects
Drawing Board display of the local coordinate system axis on selected
objects can be controlled via the ‘Drawing Board’ tab in the [Edit/User
Preferences…] dialog
4 FloTHERM New Functionality, fth10.1 June 2014
Ref. Title Description
1.5 Display of the
Solution Domain
Drawing Board display of the Solution domain can be controlled via
the ‘Drawing Board’ tab in the [Edit/User Preferences…] dialog
FloTHERM New Functionality, fth10.1 5 June 2014
Ref. Title Description
1.6 Display of
Workplane Outline
Drawing Board display of the Workplane can be controlled via the
‘Drawing Board’ tab in the [Edit/User Preferences…] dialog.
This setting will show or hide the workplane outline, but the display of
grid cells is independent of this setting.
6 FloTHERM New Functionality, fth10.1 June 2014
Ref. Title Description
1.7 De-keypointed
Indication Tolerance
Whether an object is indicated as having one or more faces de-
keypointed in the Summary Columns can now be controlled via a %
tolerance value in the ‘Summary’ tab in the [Edit/User Preferences…]
dialog
Objects that resize less than this amount, in the direction that has a de-
keypointed face, will NOT be indicated as being de-keypointed
FloTHERM New Functionality, fth10.1 7 June 2014
Ref. Title Description
1.8 Configurable display
of Integrated
Summary Columns
What summary columns are displayed next to the Project Manager
node tree can be controlled via the ‘Summary’ tab in the [Edit/User
Preferences…] dialog
8 FloTHERM New Functionality, fth10.1 June 2014
Ref. Title Description
1.9 Mirror Geometry When one or more objects are selected, a Mirror function enables those
objects to be mirrored about the workplane of the active viewport.
Either by the Mirror icon or [Geometry/Mirror] menu entry.
1.10 Workplane Location The exact location of the workplane can now be defined in the
Workplane toolbar.
FloTHERM New Functionality, fth10.1 9 June 2014
Ref. Title Description
1.11 Rotate View [Viewer\Rotate View] command added to enable full control of
viewing angle. The view can be rotated about either the model axes or
the current viewing angle.
10 FloTHERM New Functionality, fth10.1 June 2014
Ref. Title Description
1.12 Extended Measure
Tool
The measure tool has been extended to allow:
• Any number of objects to be selected
• Edge selections, in addition to vertex selection.
1.13 Find Command Find command extended to have two tabs:
1. Quick Criteria. This is the simpler Find command previously
available in v9.3 and earlier.
2. Extended Criteria. This is the query based Find command
introduced in FloTHERM v10.0.
FloTHERM New Functionality, fth10.1 11 June 2014
Ref. Title Description
1.14 Property Sheet
Sizing
All property sheets will be sized automatically upon object or attribute
selection to ensure the entire contents of all property sheet tabs are
visible.
1.15 Right-Click object
access to Property
Sheet Tabs
The Project Manager node tree supports right-click access to a list of
property sheet tabs. When a tab name is selected, the property sheet
active tab will update accordingly.
1.16 Multiple apply for
Compact
Components
Multiple apply is now supported for more Compact Component data:
• ‘General Model’ Power Definition
• ‘2-Resistor’ Model Thermal Resistances
12 FloTHERM New Functionality, fth10.1 June 2014
Ref. Title Description
1.17 Recently Used
Projects List in
different solution
directories
Selecting a project from the ‘Recently Opened List’ under the Project
menu that resides in a different solution directory will automatically
change to that solution directory and load the model.
FloTHERM New Functionality, fth10.1 13 June 2014
Ref. Title Description
1.18 Auxiliary Variables Flow Angle and Total Pressure auxiliary variables can be calculated via
the ‘Model Setup’ tab.
Once calculated they can be displayed in the Visual Editor
1.19 Zoom-In Model
Creation
Zoom-In Models can be created via a right-click option for valid
Volume Region objects.
14 FloTHERM New Functionality, fth10.1 June 2014
Ref. Title Description
1.20 Apply All to Initial
Variables
In the Solver Control tab, the Initial Variables section now has two
settings:
• All Initial Values:
o Used to make a setting that applies to all variables
• Initial Value
o Used to change the setting for the active variable.
If the Initial Value setting every variable is not identical, then the All
Initial Variables field will display ‘Set Individually’.
FloTHERM New Functionality, fth10.1 15 June 2014
Ref. Title Description
1.21 Initial Sub-Domains Initial Sub-Domains can be defined. Initial values of solved variables
can be set in these volumes whereupon they will be used as a starting
condition for a steady state or transient solution.
Initial values set in sub-domains will overwrite the intial conditions
defined elsewhere via ‘Initial Variables’ in the ‘Solver Control’ tab
16 FloTHERM New Functionality, fth10.1 June 2014
Automation
Ref. Title Description
2.1 FloXML support of
PowerMap
SmartParts
The FloXML file format can now reference PowerMap .csv files, of the
type adhering to the format exported from HyperLynxPI.
A new spreadsheet example is provided that illustrates the use of this
new feature to create an extremely detailed model of a BGA substrate
from stack up information and black and white images of the metallic
distribution.
FloTHERM New Functionality, fth10.1 17 June 2014
FloEDA Bridge
Ref. Title Description
3.1 Network Assembly
component support
Network Assembly components originating from FloTHERM Pack or
T3Ster Master (.xCTM file format) can be added to the library and used
in the construction of FloEDA Bridge models.
3.2 Monitor points for
all Simple
components
Monitor points are now created for all Simple components during
transfer. Previously, unpowered Simple components did not have a
Monitor Point.
FloMCAD Bridge
Ref. Title Description
4.1 Stand alone
operation
FloMCAD Bridge can be operated in standalone mode as in previous
versions
18 FloTHERM New Functionality, fth10.1 June 2014
Transient Analysis
Ref. Title Description
5.1 Transient Attribute
Multiplier Hysteresis
Support
Hysteresis for transient attributes can optionally be included by
defining an ‘Increasing Curve’ and a ‘Decreasing Curve’.
Solver
Ref. Title Description
6.1 Solar calculation
performance
improvements
The solar calculation has been made more efficient, and now offers
support for multiple cores. The time required to complete the solar
calculation is now much improved with the average improvement for a
range of models shown below.
FloTHERM New Functionality, fth10.1 19 June 2014
Ref. Title Description
6.2 Abort Solver During any portion of the solution, an Abort Solver Action command is
available in the Solve menu. This will stop the calculation quickly, but
without saving results. As all solver progress is lost with this
command, a confirmation dialog will appear before the solver is
aborted.
The [Solve\Revert] command can be used after an aborted solve to
restore the previous set of results if required for either solver
initialization or post-processing.
20 FloTHERM New Functionality, fth10.1 June 2014
Ref. Title Description
6.3 Linux Batch Solve For Linux systems, a new ‘Batch Solve’ script is available that supports
the full range of FloTHERM batch solve options for PDML and
FloXML files. These include:
• Initialize from a specified solution
• Write CSV Tables data after a solution
• Create a .pack file after solution
Data Center Applications
Ref. Title Description
7.1 Capture Index
Calculations
Cold Aisle Capture Index and Hot Aisle Capture Index can be
calculated by defining ‘Cold Aisle Groups’ and ‘Hot Aisle Groups’ for
Rack, Cooler, Perforated Plate, Fixed, and Recirculation Device
SmartParts.
The Capture Index calculation is activated in the Model Set Up tab:
Objects that can participate in the Capture Index calculation will have
an additional tab used to define Cold Aisle Groups and Hot Aisle
Groups.
FloTHERM New Functionality, fth10.1 21 June 2014
Application Examples
Ref. Title Description
8.1 New Application
Examples and
FloXML Examples
There are two new Application Examples installed with FloTHERM
v10.1:
Detailed FCBGA. A high resolution approach to modeling BGA
substrates using the Powermap SmartPart.
The substrate is modeled with two objects:
1 - The 'Dielectric' cuboid
2 - The 'Detailed_Substrate' PowerMap SmartPart.
Both of these objects were automatically created by the 'Detailed-
Substrate.xlsm' spreadsheet provided in
examples\FloXML\Spreadsheets installation folder. This spreadsheet
accepts layer stackup data and bitmap images that represent the copper
distribution on each of the substrate layers.
Package on Package Hysteresis. A package on package device with
temperature controlled power dissipation on the bottom die.
The entirety of the package geometry was created with the 'Package-on-
Package' spreadsheet installed in \examples\FloXML\Spreadsheets\
The temperature control is defined with the new transient hysteresis
attribute
.
8.2 FloSCRIPT
Examples
The following new files are available in the
flotherm/examples/FloSCRIPT directory:
• Linear-relaxation.xml
• Reset_solver_controls.xml
Running the Linear-Relaxation FloSCRIPT file will set all linear
relaxation values to 0.999 so that they can be modified (Linear
Relaxation values of 1 are not displayed in v10.1).
Running the ‘Reset_solver_controls’ FloSCRIPT file will set all false
time step and termination residual values back to defaults.