“Floor Area Equivalent” Court Yards, Patios, Decks (See ...

33
14 FT. AREAS ARE EXEMPT IF CUMULATIVE AREA IS 100 SQ.FT. OR LESS OR FACE A PUBLIC STREET. “Floor Area Equivalent” Court Yards, Patios, Decks (All Zones. Zoning Graphic No. 1, 1-17-06) (See CMC 86.04.307)

Transcript of “Floor Area Equivalent” Court Yards, Patios, Decks (See ...

14 FT.

AREAS ARE EXEMPT IF CUMULATIVE AREA IS 100 SQ.FT. OR LESS OR FACE A PUBLIC STREET.

“Floor Area Equivalent”Court Yards, Patios, Decks

(All Zones. Zoning Graphic No. 1, 1-17-06)(See CMC 86.04.307)

“Floor Area Equivalent”Covered Porches, Court Yards, Decks

Both are counted as “Floor Area Equivalent” since neither the roof is 65% or more permanently open to the passage of light and air to the sky nor at least 50% of the surrounding walls are 65% or more permanently open to the passage of light and air.

(All Zones. Zoning Graphic No. 2, 1-17-06)(See CMC 86.04.307)

“Floor Area Equivalent”Covered Porches, Court Yards, Decks

None of these examples are counted as “Floor Area Equivalent” since each roof is 65% or more permanently open to the passage of light and air to the sky or at least 50% of the surrounding walls are 65% or more permanently open to the passage of light and air.

(All Zones. Zoning Graphic No. 3, 1-17-06)(See CMC 86.04.307)

14’

Phantom Floor

“Floor Area Equivalent”Attics, Phantom Floors, Mezzanines

Mezzanine or Balcony

(See CMC 86.04.307)

An attic is considered as “Floor Area Equivalent” IF an attic is accessible by permanent stairs AND contains an exterior door or roof dormer open to the attic or another opening in the roof surface that admits light into the attic or provides exterior access to or from the attic. The amount of attic area to be included as floor area equivalent = 50% of the “gross floor area” of the floor below the attic.

Phantom floors above 14’ and interior mezzanines or balconies are also counted as “Floor Area Equivalent”

(All Zones. Zoning Graphic No. 4, 11-03-16)

“Story” Definition

An attic is not considered a “Story” so long as:1. The roof above has a 3:12 or greater pitch;2. The roof rafters or roof trusses are adjacent to or attached to the ceiling joists of the floor below and to the double top plate; and3. No walls are placed between the double top plate or the ceiling joists of the floor below and the roof rafters or roof trusses.

(All Zones. Zoning Graphic No. 5, 1-17-06)(See CMC 86.04.740)

Height limit as allowed for accessory buildings. Roof decks and balconies are prohibited.

Garage

40% of lot depth for lots which are greater than 110 ft. in depth.

30% of lot depth for lots which are 110 ft. or less in depth.

20% of lot depth for reverse corner lots.

Second Story Rear Yard Setback(All Single Family Zones, Except R-1A(BF) Sub-Zone. Zoning Graphic No. 6, Effective 11-03-16)

(See CMC 86.08.050, 86.08.070, 86.10.050 & 86.10.070)

“Architectural Projection”Side Yard Exception

MAX.

“Architectural Projections”, “Bay, bow, or garden windows”, chimneys, etc.: Max. 8’ each, Min. 10’ separation, & Max. cumulative length of the lesser of 20% of the façade length or 16’ (excluding window and door sills and awnings, cornices, roof eaves and gutters, and architectural features projecting a max. of 4”).(roof eaves are not limited to 24”)

(All Zones. Zoning Graphic No. 7, 11-03-06)(See CMC 86.04.094 & 86.56.580)

(All Single Family & R-3 Zones. Zoning Graphic No.8, Effective 11-03-16)

Roof Dormers(See CMC 86.08.080, 86.09.110, 86.10.080,

86.14.085 & 86.56.130)

Roof Decks & Balconies 14 ft. or Greater Above Grade(See CMC 86.08.090, 86.09.120, 86.10.085 86.14.090 & 86.56.140) (All Zones. Zoning Graphic No. 9, Effective 11-03-16)

1. Design Review Commission approval shall be required;

2. Access to decks or balconies shall not be enclosed or covered unless the access is incorporated into the roof of the building, shall not be through a roof dormer, and shall not have the appearance of a separate structure;

3. No portion of decks or balconies shall be covered and shall be 100 percent permanently open;

4. No portion of decks or balconies or the top of structures or equipment placed on said decks or balconies (e.g. fireplaces and associated chimneys, spas, barbecues, storage cabinets, mechanical equipment, or similar) shall project beyond the daylight plane or exceed the allowable building height limit;

5. Design Review Commission approval shall not be required if:a) The deck does not exceed 40 sq. ft.;b) Is solely for mechanical equipment;c) Is located below the daylight plane and

building height limit;d) Is screened by the building architecture,

not a free-standing wall and positioned a minimum of two feet from an exterior façade;

e) Is not accessed by permanent stairs or a permanent ladder;

f) Is not covered and is 100 percent permanently open to the sky.

Carriage House only for single-familyzoned lots with both street and alley access

* The second story of the main dwelling may encroach into the 50 percent setback a maximum of five percent of the lot depth for no more than half of the rear facade width, provided there is an equal or greater volume of building set back the same distance beyond the 50 percent setback line.

*

(All Single Family Zones, Except R-1A(BF). Zoning Graphic No. 10. Effective 4-18-08)(See CMC 86.04.197, 86.08.030C, 86.10.030C & 86.56.110)

CARRIAGEHOUSE

Carriage House

“Grade" is the preexisting or proposed finished ground level, whichever is lower, excluding underground basements or underground parking garages and driveways to said garages, in ground swimming pools, or other unusual topographical features which are not consistent with the natural topography of the site.

For portions of the site covered by a structure, "grade" underlying the structure shall be an assumed plane connecting "grade" at each point on the structures perimeter.

(All Zones. Zoning Graphic No. 11, 1-17-06)(See CMC 86.04.318) “Grade”

Average Front Yard Setback( All Zones. Zoning Graphic No. 12, 1-17-06)

Lot A B C D E G H

F

Lot A B D F G H

80'

GARAGE

PORCHIF VACANTOR TO BE

DEMOLISHED)

IF LESS THAN ONE-HALF OF REQUIRED

(See CMC 86.56.630)

HEIGHT LIMIT EXCEPTIONS(All Zones. Zoning Graphic No. 13, 1-17-06)(See CMC 86.56.050)

Max. 1' width & 1 sq. ft.

4' width & 16 sq. ft.

10' width & 100 sq. ft.

6' width & 36 sq. ft.

“Grade”

25’, 30’, 40’

28’, 33’, 43’

33’, 38’, 48’

35’, 40’, 50’

Max. architectural feature height for single family or duplex developments in all zones except the R-1A(BF), multi family or non-residential in the R-3 Zone, and multi family or non-residential in the R-4 or non-residential Zones, respectively.

(All Single Family Zones. Zoning Graphic No. 14. Effective 6-18-09)(See CMC 86.04.617, 86.08.035.B, 86.09.050.B & 86.10.035.B)

F.A.R. Design Feature – Front Porch

A MIN. OF TWO CORNER POSTS ARE REQUIRED

65%

(All Zones, Except R-4. Zoning Graphic No. 15. Effective 11-03-16)(See CMC 86.04.307.F & 86.56.600.C)

Covered Balcony Above Front Porch

ANY 2ND OR 3RD STORY ENCLOSED OR COVERED DECK PROJECTING GREATER THAN 8 FT. FROM THE FAÇADE SHALL BE COUNTED AS “FLOOR AREA EQUIVALENT”.

F.A.R. Design Feature #18(All Single Family Zones Except R-1A(BF). Zoning Graphic No. 16, Effective 01-06-11)(See CMC 86.04.447, 86.04.467,

86.08.035B18, & 86.10.035B18)

#18A

SOUTHERLY SIDE PROPERTY LINE

NORTHERLY SIDEPROPERTY LINE.

Side

Yar

d Se

tbac

k

Side

Yard

Setb

ack

BuildingEnvelope

HeightLimit

LOT WIDTH

Daylight Plane - 1(Applicable to Main Buildings in all Single Family Zones, Except R-1A(BF) Sub-Zone. Zoning Graphic No. 17, Effective 11-03-16)(See CMC 86.04.245, 86.04.153, 86.08.030 & 86.10.030)

“Daylight Plane” is intended to provide for light and air, and to limit the impacts of bulk and mass on adjacentproperties. The daylight plane restriction when combined with the maximum height limit, defines the “buildingenvelope” within which all new structures or additions must be contained. The daylight plane is an inclined plane,beginning at 18 feet above grade at the side property line, and extending into the site at 45 degrees from the verticalup to the maximum height limit. Main buildings shall not contain more than two stories and shall comply with theheight limits and daylight plane restrictions.

Daylight Plane - 2(Applicable to Main Buildings in all Single Family Zones, Except R-1A(BF) Sub-Zone. Zoning Graphic No. 18, Effective 11-03-16)(See CMC 86.04.245, 86.04.153, 86.08.030 & 86.10.030)

The following are exempt from the Daylight Plane requirements:a. The 45 degree off-set shall not be required along a side

property line which is adjoining and parallel to a public street, public alley or public open space.

b. The following features may extend beyond the daylight plane provided they are below the height limit:

i. Dormers, gables, cupolas, domes, skylights, parapet walls or similar architectural features provided that such features shall not exceed the height limit and the sum of the actual or implied volume of such features which project beyond the daylight plane shall not exceed a maximum of 100 cubic feet when both sides are combined *. Furthermore, no one side shall exceed 50 cubic feet except when along a “southerly side lot line” which shall be allowed a maximum of 100 cubic feet. The area of parapet walls, roof decks behind parapet walls and similar design features, shall include the volume bounded by the daylight plane, the vertical face of the parapet wall and a level plane at the top of the parapet;

ii. Cornices, eaves, and similar architectural features provided such features do not extend past the daylight plane more than 2 feet (flat roofs, flat eaves, continuous walls or enclosures of usable interior space are prohibited to extend past the daylight plane except as permitted above).

c. Chimneys and flues that do not exceed 5 feet in width, provided that chimneys do not extend past the required daylight plane a distance exceeding the minimum required by building codes.

d. Architectural features permitted by CMC Section 86.56.050.C.1.a-d.

e. Antennas.

* Volume of gable roof projecting beyond daylight plane = V

V in Cubic Feet = [Base(ft.)/2 X Ridge Length(ft.) ² ] 3

Base = horizontal width (ft.) of gable end along side façade

Base

Ridge

Page 1 of 2

CIT

Y O

F C

OR

ON

AD

O

CO

MM

UN

ITY

DE

VE

LO

PM

EN

T

Novem

ber 3, 2016

1825 STRAN

D W

AY C

OR

ON

ADO

, CALIFO

RN

IA 92118

WW

W.C

OR

ON

ADO

.CA.U

S

PRO

JEC

TS W

ITH

NO

NC

ON

FOR

MIN

G

SET

BA

CK

S

CITY HALL

PHO

NE: (619) 522-7326

FAX: (619) 522-2418

This handout is provided to architects, designers, contractors and hom

eowners w

ho are involved w

ith a remodel project involving a structure w

ith nonconforming setbacks or other

structural nonconformities. It is im

portant that you review this m

aterial prior to initiating a rem

odel project so that you understand how the C

omm

unity Developm

ent Departm

ent adm

inisters and applies regulations pertaining to nonconformities.

Coronado M

unicipal Code Section 86.50.070 Prohibition on increasing a nonconform

ity states: “Except as otherw

ise provided in this chapter, neither a nonconforming use nor a

structural nonconformity shall be enlarged, extended, expanded or in any other m

anner changed to increase its inconsistency w

ith the current zoning restrictions.” Section 86.50.090 A

lteration of structures with nonconform

ing setbacks or height: A building or structure w

hich does not conform to the yard or height regulations applicable to the

land on which such building or structure is located m

ay be structurally altered, added to, or enlarged, only w

hen: A. The alteration, addition or enlargem

ent does not increase the nonconformity and the

“proposed gross floor area” is less than 150 percent of the existing “gross floor area”; or B. The alteration, addition or enlargem

ent causes the building or structure to conform w

ith the general regulations of this title; or C

. A nonconforming accessory building m

ay be attached to a main building, if said

attachment does not increase the nonconform

ity. Section 86.50.105 V

oluntarily destroyed, damaged or altered buildings w

ith structural or floor area ratio nonconform

ities: A. Any building w

ith a “structural nonconformity” or “floor area ratio nonconform

ity” that is proposed to be structurally altered or dem

olished where m

ore than 50 percent of the exterior w

alls are removed shall be required to conform

to all City regulations as contained

herein, upon completion of any restoration or reconstruction project.

B. Any building with one or m

ore “structural nonconformity” or “floor area ratio

nonconformity” that is proposed to be enlarged w

here the proposed “gross floor area” is 150 percent or greater than the existing building “gross floor area” shall be required to conform

to all City regulations in effect at the tim

e of building permit issuance.

The following are exceptions to this requirem

ent:

Page 2 of 2

1. Approval from the D

esign Review C

omm

ission or Historic Resource C

omm

ission (if a designated historic resource); provided, that:

a. The existing architectural style shall be preserved and applied to the enlarged building; and b. The existing front facade shall be preserved in place.

Planning Departm

ent Guidelines:

1. Setbacks from

property lines shall be shown for all rem

aining walls and projections.

Measurem

ents are to be shown on a survey plat from

a Licensed Surveyor or Civil

Engineer. 2.

Each detached main or accessory building is treated individually and separately

calculated. 3.

If an alteration, addition or enlargement is planned w

here the proposed “gross floor area” is 150%

or more of the existing gross floor area then all elem

ents of the existing and proposed structure shall be required to conform

to all City regulations in effect at the tim

e of building perm

it issuance unless the project qualifies for an exemption under C

MC

Section 86.50.105.B

.1. 4.

If an alteration is planned where the proposed “gross floor area” is less than 150%

of the existing gross floor area then the follow

ing guidelines are applied: a.

Plans shall detail all proposed revisions to remaining w

alls. b.

The length, height or surface area of a nonconforming w

all cannot be increased. c.

A nonconform

ing wall cannot be rem

oved and reconstructed in kind. d.

If more than 50%

of a building's perimeter w

alls are removed, then the structure is

required to be modified to com

ply with all C

ity regulations in effect at the time of

building permit issuance.

e. M

ore than 50% of a building's 1st floor perim

eter walls shall rem

ain. f.

More than 50%

of a building's 2nd floor perimeter w

alls shall remain.

g. A

ll of the remaining w

alls shall retain a minim

um of 50%

or more of the original

studs and top and bottom plates.

h. Each floor is treated separately and each floor m

ust retain more than 50%

of its exterior perim

eter walls.

i. The w

all is considered to be the bare studs (skeleton) of the building structure, including existing top and bottom

plates. j.

The roof of a nonconforming structure m

ay be removed. The roof includes the

exterior material and roof fram

ing e.g. trusses. k.

The foundation should remain but m

ay be replaced in kind to comply w

ith latest structural codes. The building can be lifted to accom

plish the replacement. The

footprint of the nonconforming foundation cannot be increased.

l. The ability to retain a nonconform

ing setback wall is considered a privilege. A

n architect or structural engineer m

ust certify that the nonconforming w

all(s) and foundation of a nonconform

ing structure to be retained are for the majority, in

acceptable condition. This certification shall be provided as part of the building perm

it application. m

. The ceiling height or rooms located in a setback cannot be increased, and cripple

walls are not allow

ed above the existing top plates of nonconforming w

alls. See C

hapter 86.50 of the Municipal C

ode for additional information.

i:\comm

unity development\building\bldg\handouts\projects w

ith nonconforming setbacks.docx

CITY O

F CORO

NADO

DEPARTM

ENT O

F COM

MU

NITY DEVELO

PMEN

T BU

ILDING

DIVISION

1825 STRAN

D WAY, CO

RON

ADO, CA 92118

(619) 522-7331 / (619) 522-2418 (FAX) CO

MM

DEV@CO

RON

ADO.CA.U

S

HANDO

UT

111 N

OV 2016

COU

RTESY NO

TICE D

emolition, Excavation, Shoring, N

ew Construction

PURPO

SE: To inform

adjacent residents that construction activity on a subject property will com

mence in the near future.

AU

THORITY:

Coronado Municipal Code 86.08.150, 86.09.190, 86.10.140, 86.14.150 and 86.56.632

“No building or dem

olition permit for the dem

olition or new construction of 200 square feet or m

ore, in any

residential zone, except R-5, R-PCD and R-SCD zones, shall be approved unless the adjacent residents are notified in

advance of the permitted w

ork comm

encing.”

2013 California Building Code – Section 3307 Protection of Adjoining Property

“3307.1 Protection Required. Adjoining public and private property shall be protected from dam

age during construction, remodeling and

demolition w

ork. Protection shall be provided for footings, foundations, party walls, chim

neys, skylights and roofs. Provisions shall be made to

control water runoff and erosion during construction or dem

olition activities. The person making or causing an excavation to be m

ade shall

provide w

ritten notice to the owners of adjoining buildings advising them

that the excavation is to be made and that the adjoining buildings

should be protected. Said notification shall be delivered not less than 10 days prior to the scheduled starting date of the excavation.” N

OTES:

1. A permit to proceed w

ith demolition or construction w

ill not be issued for a minim

um of 10 calendar days from

the date of this notice.

2. Applicant must subm

it envelopes prepared with the applicant’s return address, the recipient’s address (as listed

below), and proper postage to the Building Division for m

ailing of the Courtesy Notice by the City of Coronado.

Enclose 1 copy of this Courtesy Notice in each envelope.

3. Envelopes shall be addressed: Resident At (Parcel Address)

Coronado, CA 92118

4. Applicant must subm

it a listing of addresses to which the Courtesy N

otice has been sent. The Applicant may

request a listing of addresses requiring this Courtesy Notice from

the Building Division.

DATA:

1. Application Date :________________ Project Address:_______________________________________________

2. Project Description: ___________________________________________________________________________

____________________________________________________________________________________________

3. � Demolition � Excavation � Shoring � N

ew Construction (CHECK ALL THAT APPLY)

4. Property Ow

ner: _____________________________________________________________________________

(N

ame)

(Address)

_____________________________________________________________________________

(Phone #)

(E-Mail)

5. Contractor: _____________________________________________________________________________

(Nam

e)

(Address)

_____________________________________________________________________________

(Phone #) (E-M

ail) RECIPIEN

T: As recipient of this Courtesy N

otice, you may w

ant to contact the Ow

ner or Contractor to learn the details of the

project or w

hen actual construction activities will com

mence so you can take appropriate m

easures to minim

ize

dust, noise or other im

pacts on your property. Construction plans may be available for your review

at the Building

Division O

ffice in City Hall. Please call (619) 522-7331 to ensure that plans have actually been submitted.

i:\comm

unity development\building\bldg\w

ebsite docs\word versions\handout #111 courtesy notice.doc

I:\Bldg\H

ANDOUTS\H

ANDOUT #15 - L

ot B

ldg Cert R

equire

ments.d

oc

Community Development Departm

ent

City of Coronado Public H

andout #15

LOT AND BUILDING CERTIFICATION REQUIREMENTS FOR ALL

PROPERTY UNDER THE JURISDICTION OF THE CITY OF

CORONADO EXCEPT THE CORONADO CAYS

Effectiv

e July 22, 2005. R

evised

June 18, 2009.

In acco

rdance w

ith sectio

n 86.56.635 of th

e Coronado M

unicip

al Code, th

e follo

wing Lot an

d B

uild

ing

Certificatio

n Requirem

ents are n

ecessary:

86.56.635

Lot and building certifica

tion req

uired

.

A.

All co

nstru

ction plan

s for n

ew or rep

lacement b

uild

ings o

r the ad

ditio

n of n

ew sq

uare fo

otag

e to

existin

g build

ings, w

here an

y portio

n of th

e new

or rep

lacement b

uild

ing or b

uild

ing ad

ditio

n is

over 5

00 sq

uare feet, sh

all inclu

de:

1.

The fo

llowing provided by a C

alifornia licen

sed lan

d su

rveyor o

r civil en

gineer:

a. Lot lin

e distan

ces;

b.

Gross lo

t area;

c. Descrip

tion an

d lo

cation of all co

rner m

onuments; an

d

d.

Existin

g and proposed

grad

e, which

ever

is lower,

with

one-fo

ot contour lin

es

shown with

the b

enchmark

locatio

n an

d data id

entified

.

2.

Corner m

onuments, if n

ot cu

rrently

set, shall b

e set, mapped an

d certified

by a C

alifornia

licensed

land su

rveyor o

r civil en

gineer.

B.

Prio

r to a fo

undatio

n an

d fram

ing in

spectio

n by a b

uild

ing in

specto

r and upon co

mpletio

n of

exterio

r framing fo

r new

or rep

lacement b

uild

ings o

r the fo

undatio

n or fram

ing fo

r the ad

ditio

n of

new

square fo

otag

e to ex

isting build

ings w

here an

y portio

n of th

e new

or rep

lacement b

uild

ing or

build

ing additio

n is

over

500 square

feet or more

than 14 feet

in heig

ht,

certification by a

Califo

rnia

licensed

lan

d surveyor or civ

il engineer

shall

be

provided to the

Community

Develo

pment D

epartm

ent certify

ing th

at the fo

llowing co

mply with

the ap

proved plan

s:

1.

Foundatio

n and build

ing heig

ht fro

m grad

e usin

g the

same

benchmark

identified

in

subsectio

n (A

)(1)(d

) of th

is section;

2.

Foundatio

n an

d build

ing setb

ack distan

ces from all p

roperty

lines; an

d

3.

Foundatio

n an

d build

ing arch

itectural p

rojectio

ns fro

m all setb

ack lin

es.

C.

Notw

ithstan

ding su

bsectio

ns A

or B

of th

is section an

d due to

unique lo

t or site co

nditio

ns, th

e

Directo

r of C

ommunity

Develo

pment is h

ereby au

thorized

to req

uire a p

roperty

owner to

provide th

e inform

ation called

for in

subsectio

ns A

and B of th

is section as n

eeded to

assure

new

develo

pment is co

nsisten

t with

zoning reg

ulatio

ns.

FEN

CE

S, WA

LL

S, & H

ED

GE

S ZO

NIN

G R

EST

RIC

TIO

NS

Municipal C

ode Title 86 N

ovember 3, 2016

Note:

The following regulations are excerpts; additional ordinances in other chapters m

ay apply. 86.04.295

Fences, walls and hedges, height of. "H

eight of fences, walls and hedges" m

eans the vertical distance from

"grade" or the ground level of public property closest to the property line on w

hich the fence, wall or hedge is located; w

hichever is lower, to the highest point on the fence, w

all or hedge. The height of a fence, w

all or hedge separating private property shall mean the vertical distance

from "grade" to the highest point on the fence, w

all, or hedge. Where a property line separates

property having unequal ground levels, the lower "grade" shall be used to m

easure the vertical distance of the fence, w

all, or hedge. (Ord. 1971 § 2, 2005)

86.56.160 Fences, walls or hedges – H

eight limit, side or rear yard. A

ny fences, walls or hedges

located in Residential Zones shall not exceed eight feet in height in a required side or rear yard and six

feet in the area between the front or side lot line and the nearest building located on the lot w

hen no front or side yard is required. (O

rd. 1971 § 2, 2005) 86.56.165 Fences, w

alls or hedges – Height lim

it, front yard. A

. Fences, walls, or hedges located w

ithin the required front yard shall not exceed four feet in height. The follow

ing are exceptions to this requirement:

1. A fence or w

all up to six feet in height may be located along the side property lines, w

ithin the front yard, and project into the front yard eight feet. Said six foot fence or w

all shall extend no closer than 10 feet to the front property line;

2. Those lots which front solely on an alley or the follow

ing streets may enclose 100 percent of

their front yards with an eight-foot w

all, fence, or hedge: Third Street between A

Avenue and

Alam

eda Boulevard, all of Fourth Street, A

lameda B

oulevard between Third and Fourth Street

and Pomona A

venue between Third and Fourth Street. W

here walls or fences are perm

itted to be over four feet in height and adjoin public rights-of-w

ay, said wall or fence shall be buffered

with landscaping to soften the fence or w

all. The proposed landscaping shall be approved by the C

ity of Coronado prior to installation. W

alls or fences over four feet in height, adjacent to an alley, are not required to be buffered w

ith landscaping. (Ord. 2062 § 2 (Exh. A

), 2016) 86.56.170 Fences, w

alls or hedges – Height lim

it, street side yard. Fences, walls, or hedges shall

not exceed six feet in height in any required street side yard required on any corner lot. Exception: Those lots w

hich are located along the following streets m

ay construct a fence, wall, or

hedge not to exceed eight feet in height along the street side yard: Third Street between A

Avenue and

Alam

eda Boulevard, all of Fourth Street, A

lameda B

oulevard between Third and Fourth Street and

Pomona A

venue between Third and Fourth Street. W

here walls or fences are perm

itted to be over four feet in height in the street side yard, said fences or w

alls shall not be located within the sight triangle

required in CM

C 86.56.175. (O

rd. 1971 § 2, 2005) 86.56.175 V

ertical barriers – Fences, walls or hedges – H

eight limit, sight triangle for residential

corner lot. In the case of corner lots in Residential Zones, vertical barriers, including fences, w

alls and hedges, shall not exceed three feet in height in a triangle area created by a line connecting points along the street curb lines w

hich are established 50 feet in distance from the intersection of such curb

lines at the corner of a block. Exception: Single stem plants or trees w

ithout foliage between a height

of three and eight feet may be planted and m

aintained within the corner triangular area and shall be

measured from

the established curb grade. (Ord. 1971 § 2, 2005) (N

OTE: See diagram

#1) i:\com

munity developm

ent\building\bldg\handouts\handout #3 - fence zoning.doc

DIA

GR

AM

#1 SIT

E T

RIA

NG

LE

FOR

CO

RN

ER

LO

TS.

RE

STR

ICT

ED

FEN

CE

, WA

LL

, & H

ED

GE

HE

IGH

T

Fences, Walls, H

edges M

ax. 3 ft. in Height

City of C

oronado Public Handout #12

SLO

PED

DR

IVE

WA

YS

Novem

ber 3, 2016 Purpose:

Relate m

inimum

construction specifications for sloped driveways leading to subterranean

parking garages on private property.

R

elate requirements for H

ydrology Studies necessitated by subterranean parking garages. A

ttachment: C

ity of Coronado Engineering Services letter and sloped drivew

ay diagram

Diagram

s: 1.

Sloped driveway w

/transitions

N

otes: 1.

Primary ram

ps shall have a 20% m

aximum

slope and a minim

um eight foot

horizontal run. 2.

Primary ram

ps over 14% slope shall have a transition ram

p of at least eight feet

(8’-0”) at each end of the primary ram

p. The transition ramp shall slope at one-half

the degree of the prim

ary ramp.

3. R

amps w

ith a slope of 14% or greater shall be surfaced w

ith asphalt or concrete w

ith a deep broom finish perpendicular to the direction of travel.

4. In all cases the design of the drivew

ay shall prevent contact of any portion a vehicle w

ith the ramp.

5. N

o required parking shall be allowed on ram

ps greater than 14%.

i:\comm

unity development\building\bldg\handouts\handout #12 - sloped drivew

ays.doc

pfait
Text Box
1.Primary ramps shall have a 20% maximum slope and a minimum eight foot horizontal run. 2.Primary ramps over 14% slope shall have a transition ramp of at least eight feet (8'-0”) at each end of the primary ramp. The transition ramp shall slope at one-half the degree of the primary ramp. 3.Ramps with a slope of 14% or greater shall be surfaced with asphalt or concrete with a deep broom finish perpendicular to the direction of travel. 4.In all cases the design of the driveway shall prevent contact of any portion a vehicle with the ramp. 5.No required parking shall be allowed on ramps greater than 14%.
pfait
Text Box
Transition ramp 1/2 slope of primary ramp. Maximum 10%
pfait
Text Box
Transition ramp 1/2 slope of primary ramp. Maximum 10%
pfait
Text Box
8' minimum

CIT

Y O

F C

OR

ON

AD

O

EN

GIN

EE

RIN

G &

PR

OJE

CT

DE

VE

LO

PM

EN

T D

EP

AR

TM

EN

T

ME

MO

RA

ND

UM

DA

TE

: June 2, 2005

TO

: B

uilders of Subterranean G

arages/Cellars

FR

OM

: Jam

es F. Benson

Director of E

ngineering & P

roject Developm

ent

SUB

JEC

T:

HY

DR

OL

OG

Y S

TU

DIE

S

It is

the C

ity of

Coronado's

policy that

the proposed

construction of

subterranean garages/cellars w

ill, as part of the design process, include a hydrology study if the driveway

or walkw

ay to the underground garage begins its descent on City property (i.e., directly

behind the sidewalk).

On m

ost streets in the City, private property begins four feet behind

the sidewalk, or sixteen feet from

the curb face. It is the C

ity of Coronado's policy that the

sidewalk w

ill not be depressed in the area of the drivew

ay crossing. If the descending

driveway is w

holly contained within private property a hydrology study w

ill not be required. H

owever, a prudent developer w

ill have a study performed to clearly define the level of risk

exposure.

The C

ity of Coronado's property slopes up from

the top of curb to the private property line at a grade of 2%

. In m

ost cases, as discussed above, this is a rise of 0.32 feet. It is intended

that the flood waters associated w

ith the 100-year design storm be contained w

ithin the public right of w

ay, including the street, gutter and parkway area, until the w

ater can be transported to the storm

drain, and finally the ocean outfall. T

his containment of the 100-

year design stormw

ater is intended to minim

ize damage to private property.

Alteration

of this containm

ent area

by sloping

a drivew

ay dow

n to

an underground

garage/cellar within the public right of w

ay may cause extensive dam

age to private property as a result of flooding.

How

ever, depending on the topography of the particular location, a hydrology study m

ay reveal that there is adequate drainage, allowing the descent to private

property to begin in the public right of way.

The hydrology study m

ust be performed and stam

ped by a California R

egistered Engineer.

The study m

ust conform to the C

ounty of San D

iego Hydrology M

anual and be based on the 100-year design storm

. If the study show

s that flooding will occur during the 100-year

design storm

, the

subterranean garage/cellar cannot be

constructed. T

here w

ill be

no exceptions.

Exam

ples of completed studies are available at the E

ngineering &

Project D

evelopment

Departm

ent, 1825 Strand W

ay, Coronado, C

A 92118. Phone:

(619) 522-7383