FlexWave ® Active Integration Panel Installation and Configuration Guide FWPP-518-01 February 2017 BIU-1 BIU-2 BIU-3 BIU-4 BIU-5 BIU-6 BIU-7 BIU-8 QMA-1 QMA-2 QMA-3 QMA-4 QMA-5 QMA-6 QMA-7 QMA-8 - UL - - DL - AIP-CSU Status Power EXPANSION1 EXPANSION2 CRAFT ADMIN/LAN 48 V 5 A, max + AIP-ACU Status Power AIP-BIU BTS Tx/Rx Sample Port Status Power AIP-BIU BTS Tx/Rx Sample Port Status Power AIP-BIU BTS Tx/Rx Sample Port Status Power AIP-BIU BTS Tx/Rx Sample Port Status Power AIP-BIU BTS Tx/Rx Sample Port Status Power AIP-BIU BTS Tx/Rx Sample Port Status Power AIP-BIU BTS Tx/Rx Sample Port Status Power AIP-BIU BTS Tx/Rx Sample Port

Transcript of FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power...

Page 1: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

FlexWave® Active Integration Panel

Installation and Configuration Guide • FWPP-518-01 • February 2017

BIU-1 BIU-2 BIU-3 BIU-4 BIU-5 BIU-6 BIU-7 BIU-8

QMA-1 QMA-2 QMA-3 QMA-4 QMA-5 QMA-6 QMA-7 QMA-8

- UL -

- DL -AIP-CSU

Status

Power

EXPANSION1

EXPANSION2

CRAFT

ADMIN/LAN

48 V5 A, max

+

AIP-ACU

Status

Power

AIP-BIU

BTSTx/Rx

Sample Port

Status

Power

AIP-BIU

BTSTx/Rx

Sample Port

Status

Power

AIP-BIU

BTSTx/Rx

Sample Port

Status

Power

AIP-BIU

BTSTx/Rx

Sample Port

Status

Power

AIP-BIU

BTSTx/Rx

Sample Port

Status

Power

AIP-BIU

BTSTx/Rx

Sample Port

Status

Power

AIP-BIU

BTSTx/Rx

Sample Port

Status

Power

AIP-BIU

BTSTx/Rx

Sample Port

Page 2: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

DISCLAIMERThisdocumenthasbeendevelopedbyCommScope,andisintendedfortheuseofitscustomersandcustomersupportpersonnel.Theinformationinthisdocumentissubjecttochangewithoutnotice.Whileeveryefforthasbeenmadetoeliminateerrors,CommScopedisclaimsliabilityforanydifficultiesarisingfromtheinterpretationoftheinformationcontainedherein.Theinformationcontainedhereindoesnotclaimtocoveralldetailsorvariationsinequipment,nortoprovideforeverypossibleincidenttobemetinconnectionwithinstallation,operation,ormaintenance.Thisdocumentdescribestheperformanceoftheproductunderthedefinedoperationalconditionsanddoesnotcovertheperformanceunderadverseordisturbedconditions.Shouldfurtherinformationbedesired,orshouldparticularproblemsarisewhicharenotcoveredsufficientlyforthepurchaser'spurposes,contactCommScope.CommScopereservestherighttochangeallhardwareandsoftwarecharacteristicswithoutnotice.COPYRIGHT©2017CommScope,Inc.AllRightsReserved.Alltrademarksidentifiedby®or™areregisteredtrademarksortrademarks,respectively,ofCommScope,Inc.Thisdocumentisprotectedbycopyright.Nopartofthisdocumentmaybereproduced,storedinaretrievalsystem,ortransmitted,inanyformorbyanymeans,electronic,mechanicalphotocopying,recording,orotherwisewithoutthepriorwrittenpermissionofCommScope.OTHER TRADEMARKSNamesofotherproductsmentionedhereinareusedforidentificationpurposesonlyandmaybetrademarksand/orregisteredtrademarksoftheirrespectivecompanies.

Page 3: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

TABLE OF CONTENTS

1 Using this Document _______________________________________________________________________________________ 1Document Revision History ........................................................................................................................................................................................2Document Cautions and Notes ..................................................................................................................................................................................3Document Fonts .........................................................................................................................................................................................................4

2 ACTIVE INTEGRATION PANEL OVERVIEW_______________________________________________________________________ 5Product Overview.......................................................................................................................................................................................................6AIP Components.........................................................................................................................................................................................................7

AIP Control Unit..................................................................................................................................................................................................8Base Station Interface Units ...............................................................................................................................................................................9Combiner/Splitter Unit.....................................................................................................................................................................................10Mapping the CSU and BIU Installation and Connections .................................................................................................................................11Fan Modules .....................................................................................................................................................................................................13

3 Installing the AIP _________________________________________________________________________________________ 15Prepare for Installation ............................................................................................................................................................................................16

Install the AIP Safely .........................................................................................................................................................................................16Guard against Damage from Electro-Static Discharge .....................................................................................................................................16Unpack and Inspect the AIP Chassis and Modules ...........................................................................................................................................16

Install the AIP Chassis in an Equipment Rack ...........................................................................................................................................................17Determine the Mounting Method....................................................................................................................................................................17Removing the Factory Installed Mounting Ears ...............................................................................................................................................18Mounting the AIP in a Two-Post Rack ..............................................................................................................................................................19Mounting the AIP in a Four-Post Rack..............................................................................................................................................................21Securing the AIP Chassis to the Equipment Rack .............................................................................................................................................22

Ground the AIP Chassis ............................................................................................................................................................................................23Install Power Wiring .................................................................................................................................................................................................24Install the CSU Tray ..................................................................................................................................................................................................26Install the BIU(s) .......................................................................................................................................................................................................27Connect the BIU to the BTS ......................................................................................................................................................................................28Connect the CSU.......................................................................................................................................................................................................29

Connect the CSU to a Prism/Spectrum Host Unit ............................................................................................................................................29Connect the CSU to a Fusion Main Hub ...........................................................................................................................................................31

4 USING THE AIP ELEMENT MANAGEMENT SOFTWARE ___________________________________________________________ 33Following the EMS Procedures in this Guide............................................................................................................................................................35Using the GUI Components ......................................................................................................................................................................................36

Tab Frame.........................................................................................................................................................................................................37System Tree......................................................................................................................................................................................................38

Web Browser Requirements and Setup ...................................................................................................................................................................39Access the AIP EMS for the First Time......................................................................................................................................................................43Set the Network Connections ..................................................................................................................................................................................45

Set Network Connections Automatically..........................................................................................................................................................45Set Network Connections Manually .................................................................................................................................................................47

Synchronize AIP Date and Time with an NTP Server ................................................................................................................................................48Set the System Information......................................................................................................................................................................................49

Set the System Name .......................................................................................................................................................................................49Configure an AIP...............................................................................................................................................................................................50Label an Individual Main or Secondary AIP ......................................................................................................................................................51

Label an AIP Option 1 ...............................................................................................................................................................................51Label an AIP Option 2 ...............................................................................................................................................................................52

Label an ACU ....................................................................................................................................................................................................52Label an ACU Option 1..............................................................................................................................................................................52Label an ACU Option 2..............................................................................................................................................................................53

Label a CSU .......................................................................................................................................................................................................53Label a CSU Option 1 ................................................................................................................................................................................54Label a CSU Option 2 ................................................................................................................................................................................54

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page iii

Page 4: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Table of Contents

Set Up SNMP ............................................................................................................................................................................................................55Set Up SNMP Trap Managers ...................................................................................................................................................................................56Deleting an SNMP Trap Manager .............................................................................................................................................................................59Modifying an SNMP Trap Manager ..........................................................................................................................................................................61Calibrate the CSU with the BIUs ...............................................................................................................................................................................62Managing BIUs .........................................................................................................................................................................................................67

Getting BIU Information ...................................................................................................................................................................................67Getting Information about Bands ....................................................................................................................................................................68Configuring BIUs ...............................................................................................................................................................................................69

Changing the Configuration of a BIU ........................................................................................................................................................70BIU Configuration Parameters..................................................................................................................................................................72

Using Diagnostic Tones.....................................................................................................................................................................................75Backing up BIU Configurations .........................................................................................................................................................................77Restoring a Backed Up BIU Configuration ........................................................................................................................................................78Exporting a BIU Configuration File to a PC .......................................................................................................................................................80Importing and Restoring a BIU Backup File from a PC .....................................................................................................................................82Deleting a Backed Up BIU Configuration..........................................................................................................................................................83Deleting a BIU from the AIP System Setup.......................................................................................................................................................85

Option 1: Deleting a BIU from the AIP System Setup...............................................................................................................................85Option 2: Deleting a BIU from the AIP System Setup...............................................................................................................................86

Resetting AIP Components to Factory Default Settings ...................................................................................................................................87Getting System Information.....................................................................................................................................................................................89

Get System Information for All AIPs.................................................................................................................................................................89Get ACU Information........................................................................................................................................................................................91Get CSU Information ........................................................................................................................................................................................92

Rebooting an ACU ....................................................................................................................................................................................................93Troubleshooting NTP Server Errors..........................................................................................................................................................................94Running a Self Mapping Test on a CSU.....................................................................................................................................................................96Viewing Alarms.........................................................................................................................................................................................................97

Alarm Indicators ...............................................................................................................................................................................................97Viewing Alarm Details on an ACU or CSU Get Information Page .....................................................................................................................98Viewing BIU Alarm Details..............................................................................................................................................................................100View Current Alarms ......................................................................................................................................................................................102View an Alarm History....................................................................................................................................................................................104

Filtering the View History Table .............................................................................................................................................................105Exporting an Alarm History ....................................................................................................................................................................107

Clearing the Alarm History .............................................................................................................................................................................110Clearing Disconnect Alarms....................................................................................................................................................................................111Upgrading an AIP System .......................................................................................................................................................................................112Using a Static IP Address for the Main AIP Craft Port ............................................................................................................................................113Managing Users......................................................................................................................................................................................................116

Viewing Users .................................................................................................................................................................................................116Add a New User..............................................................................................................................................................................................117Delete a User ..................................................................................................................................................................................................119Change the Password of another User...........................................................................................................................................................120Changing Your Own Password........................................................................................................................................................................121

Viewing the AIP EMS Release Information.............................................................................................................................................................122Logging Out of the AIP............................................................................................................................................................................................123Alarm Reference.....................................................................................................................................................................................................124

5 WORKING WITH CASCADED AIPs ___________________________________________________________________________ 127Install the AIPs........................................................................................................................................................................................................128Verify the AIP EMS Release on each AIP ................................................................................................................................................................129Establish the Main AIP............................................................................................................................................................................................130Designate Cascaded AIPs as Secondary Units in the AIP EMS................................................................................................................................131Physically Cascade the AIPs....................................................................................................................................................................................133Managing Cascaded AIPs........................................................................................................................................................................................134Troubleshooting Secondary Units ..........................................................................................................................................................................135

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page iv ©February 2017 CommScope, Inc.

Page 5: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Table of Contents

A Using an External Combiner/Splitter Shelf ___________________________________________________________________ 137External Combiner/Splitter Shelf Product Overview..............................................................................................................................................138

Combiner/Splitter Module for the External Combiner/Splitter Shelf ............................................................................................................139Deployment Examples for the External Combiner/Splitter Shelf...................................................................................................................140

Two Sectors, Each Sector Split into Two Zones ......................................................................................................................................141One Sector Split into Four Zones............................................................................................................................................................142Four Sectors with One Zone per Sector..................................................................................................................................................143

Installing an ECSS....................................................................................................................................................................................................144Install the AIP .................................................................................................................................................................................................144Install the ECSS into the Equipment Rack.......................................................................................................................................................144Connect the AIP CSU to the ECSS ...................................................................................................................................................................145Connect the ECSS to the DAS .........................................................................................................................................................................145

Connect the ECSS to a Prism/Spectrum Host Unit .................................................................................................................................145Connect the ECSS to a Fusion Main Hub ................................................................................................................................................147

B Specifications___________________________________________________________________________________________ 149RF Performance......................................................................................................................................................................................................150Technical Specifications .........................................................................................................................................................................................151

AIP Chassis......................................................................................................................................................................................................151AIP BIUs ..........................................................................................................................................................................................................151AIP CSU ...........................................................................................................................................................................................................152External Combiner/Splitter Shelf (ECSS).........................................................................................................................................................152

Standards Certification...........................................................................................................................................................................................153

C DCCS Global Technical Support_____________________________________________________________________________ 155Contacting Global Technical Support .....................................................................................................................................................................156

Telephone Helplines.......................................................................................................................................................................................156Online Support ...............................................................................................................................................................................................156

DCCS Technical Training .........................................................................................................................................................................................157Accessing User Documentation..............................................................................................................................................................................158

Accessing Prism User Documentation............................................................................................................................................................158Accessing Spectrum User Documentation .....................................................................................................................................................158Accessing InterReach Fusion User Documentation........................................................................................................................................159

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page v

Page 6: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Table of Contents

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page vi ©February 2017 CommScope, Inc.

Page 7: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Chapter Topics Page

Document Revision History ........................................................................................................................................................................................1Document Cautions and Notes ..................................................................................................................................................................................1Document Fonts .........................................................................................................................................................................................................2

TheFlexWave®userdocumentationisintendedforsystemadministrators,engineersandinstallersresponsibleforplanning,administering,configuring,andmaintainingCommScopeFlexWavesystems.ForinformationonhowtodownloadacopyofaCommScopeDCCSuserdocument,goto"AccessingInterReachFusionUserDocumentation”onpage 159.Forinformationspecifictousingthisdocument,refertothesectionsbelow.

USING THIS DOCUMENT1

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 1

Page 8: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Document Revision History

DOCUMENT REVISION HISTORY

CommScopehasacquiredTEConnectivity'stelecom,enterpriseandwirelessbusiness,whichincludestheFlexWaveActiveIntegrationPanel(AIP)productline;CommScopedocumentFWPP-518-01replacesTEdocumentTECP-77-227.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 2 ©February 2017 CommScope, Inc.

Page 9: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Document Cautions and Notes

DOCUMENT CAUTIONS AND NOTES

Twotypesofmessages,identifiedbelow,appearinthetext:CAUTION! Caution text indicates operations or steps that could cause personal injury, induce a safety problem in

a managed device, destroy or corrupt information, or interrupt or stop services.

NOTE: Note text contains information about special circumstances.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 3

Page 10: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Document Fonts

DOCUMENT FONTS

Youwillfindthefollowingfontconventionsinusethroughoutthedocument.• This fontrepresentsareferencetoaAdminBrowserdialogbox,menuitem,configurationoption,orotherparameter.• <This Font>inanglebracketsrepresentsareferencetoaAdminBrowserdialogbox,menuitem,configurationoption,orotherparameterthatisavariable.Thetextwithintheanglebracketschangesaccordingtoagetorsetcommand.Forexample:

– ThePassword for <username> has been changed messagedisplays.– ThePassword for JohnSmith has been changed messagedisplays.

• This fontrepresentsnon-variabletextthatyoutypeataprompt.• THIS FONTrepresentskeysthatyouneedtopressonyourkeyboard.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 4 ©February 2017 CommScope, Inc.

Page 11: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Chapter Topics Page

Product Overview.......................................................................................................................................................................................................4AIP Components.........................................................................................................................................................................................................5

AIP Control Unit..................................................................................................................................................................................................6Base Station Interface Units ...............................................................................................................................................................................7Combiner/Splitter Unit.......................................................................................................................................................................................8Mapping the CSU and BIU Installation and Connections ...................................................................................................................................9Fan Modules .....................................................................................................................................................................................................11

ThismanualprovidesinstructionsonhowtoinstallandconfigureaCommScopeActiveIntegrationPanel(AIP)anditsoptionalExternalCombiner/SplitterShelf(ECSS).Table 2-1liststheAIPchassisandcorrespondingmodules,andExternalCombiner/Splittershelfsthatthisinstallationguidesupports.

ACTIVE INTEGRATION PANEL OVERVIEW 2

Table 2-1. Products Supported in this Installation Guide

Part Number Description

Active Integration PanelAIP-HU-1 Chassis

AIP-CU-1 AIP Control Unit (ACU)

AIP-CSU-1 Split/Comb Tray, Config1

AIP-CSU-2 Split/Comb Tray, Config2

AIP-CSU-3 Split/Comb Tray, Config3

AIP-CSU-4 Split/Comb Tray, Config4

AIP-BIU700ABC-1 RF Module, 700ABC

AIP-BIU700UC-1 RF Module, 700UC

AIP-BIU800-1 RF Module, 800MHz

AIP-BIU850-1 RF Module, 850MHz

AIP-BIU1900-1 RF Module, 1900MHz

AIP-BIUAWS-1 RF Module, 2100MHz

AIP-BIU2300-1 RF Module, 2300 MHz

AIP-BIU2500-1 RF Module, 2500 TDD

AIP-BIUTERM-1 RF Module, Termination

AIP-BIUBLANK-1 RF Module, Blank

External Combiner/Splitter ShelfAIP-ESC-1 External Shelf, Chassis

AIP-ESM-1 External Shelf, Module

AIP-ESBLANK-1 External Shelf, Blank Cover

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 5

Page 12: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Product Overview

PRODUCT OVERVIEW

TheCommScopeActiveIntegrationPanel(AIP)providesastructuredcomponentinterfacebetweentheRFsourceandDAShostunits.AsingleAIPsupportsuptoeightBaseStationTX/RXinputs.TheAIPcontainsallrequiredRFcomponents,thusreducinginstallationcomplexityandlaborcosts.TheAIP:• canaddressupto32chassiswithoneIPaddress• providesaninternalpre-configuredCombiner/Splittertray• providesadiagnostictoneforcommissioningandtroubleshooting• meetsNEBScarriergradelevel1requirements• supports:

– upto8BaseStationTX/RXInputs– ALCinDLpathwithuserconfiguredalarmthresholdandautomaticattenuation– anInputRangeof0.25Wto100W– remotecontrolandmonitoringviaweb– UL&DLpowerlevelmonitoring– IPv4andIPv6networkingprotocol

• iscompatiblewiththefollowingCommScopeproductlines– InterReachFusion– FlexWavePrism– FlexWaveSpectrum

NOTE: For information about the optional External Combiner/Splitter Shelf (ECSS), which provides further flexibility to the standard AIP configurations, see "Using an External Combiner/Splitter Shelf” on page 137.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 6 ©February 2017 CommScope, Inc.

Page 13: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

AIP Components

AIP COMPONENTS

TheAIPchassis(showninFigure 2-1,withoutthemountingbrackets)comprisesthefollowingcomponents:• oneAIPControlUnit(ACU)• uptoeightBaseStationInterfaceUnits(BIUs)• oneCombiner/SplitterUnit(CSU).

Figure 2-1. Fully Loaded AIP Chassis

BIU-1 BIU-2 BIU-3 BIU-4 BIU-5 BIU-6 BIU-7 BIU-8

QMA-1 QMA-2 QMA-3 QMA-4 QMA-5 QMA-6 QMA-7 QMA-8

- UL -

- DL -AIP-CSU

Status

Power

EXPANSION1

EXPANSION2

CRAFT

ADMIN/LAN

48 V5 A, max

+

AIP-ACU

Status

Power

AIP-BIU

BTSTx/Rx

Sample Port

Status

Power

AIP-BIU

BTSTx/Rx

Sample Port

Status

Power

AIP-BIU

BTSTx/Rx

Sample Port

Status

Power

AIP-BIU

BTSTx/Rx

Sample Port

Status

Power

AIP-BIU

BTSTx/Rx

Sample Port

Status

Power

AIP-BIU

BTSTx/Rx

Sample Port

Status

Power

AIP-BIU

BTSTx/Rx

Sample Port

Status

Power

AIP-BIU

BTSTx/Rx

Sample Port

ACU Eight BIUs (RF Modules)

CSU

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 7

Page 14: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

AIP Components

AIP Control UnitTheAIPControlUnit(ACU)providestherequiredsystemmanagementandcontrolfortheAIP.TheACUcontrolsandmonitorstheAIPBIUsandprovidestheabilitytomonitorandmodifythesystemRFperformance.TheACUconnectsdirectlytoanexternal48VdcpowersourceanddistributesthepowertotheAIPChassis.Ref # Component Function

3, 4 Expansion/cascade ports Allows the AIP to be cascaded to another AIP Unit, a maximum of 32 AIPs can cascade to a single IP address.

5 Craft port Acts as a Craft port for local access.

6 Network Access port Provides access to the Ethernet LAN.

7 48 Vdc Power Connector Connects to external 48 Vdc power source.

Ref # LED LED Color Description

1 Status• Green • ACU does not have an alarm.• Yellow • ACU has a minor alarm.• Red • ACU has a major alarm.

2 Power

• Green • Power to the ACU is on and the output voltage is normal.

• Red • Power to the ACU is on and the output voltage is abnormal.

• Off • Power to the ACU is off.

12

3

7

4

5

6

Status

Power

EXPANSION1

EXPANSION2

CRAFT

ADMIN/LAN

48 V5 A, max

+

AIP-ACU

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 8 ©February 2017 CommScope, Inc.

Page 15: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

AIP Components

Base Station Interface UnitsBaseStationInterfaceUnits(BIUs)providetheRadioFrequencyinterfacebetweentheBaseStationandtheCSU.EachBIUisbandspecificandsupportsoneoftheRFfrequencieslistedbelow(seealso"RFPerformance”onpage 150).• Band4—2100AWS• Band5—850Cell• Band12—700ABC• Band13—700UC• Band25—1900PCS• Band27—800ESMR/iDEN• Band30—2300WCS• Band41—2500TDD.

Ref # Component Function

3 BTS Tx/Rx port Connects to the Base Station via 7/16 DIN female connector; acts as a duplex connection through the BIU, which is routed to the backplane.

4 Sample Port QMA female port that acts as an uplink Sample/Simplex port.

Ref # LED LED Color Description

1 Status• Green • BIU does not have an alarm.• Yellow • BIU has a minor alarm.• Red • BIU has a major alarm.

2 Power

• Green • Power to the BIU is on and the output voltage is normal.

• Red • Power to the BIU is on and the output voltage is abnormal.

• Off • Power to the BIU is off.

Status

Power

AIP-BIU

BTSTx/Rx

Sample Port

12

3

4

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 9

Page 16: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

AIP Components

Combiner/Splitter UnitTheCombiner/SplitterUnit(CSU)isapull-outdrawerthathousespassivecombinersandcomespre-configuredwithfourstandardconfigurations(seeFigure 2-2onpage 12).TheCSUistheprimaryRFinterfacebetweentheAIPandtheRFnetwork.

NOTE: Although the CSU Modules ship with all eight DL ports populated, you must connect the DL ports according to the diagram on each CSU Module faceplate; these diagrams show the only valid DL connections you can make that work with the four pre-configured, standard CSU configurations.

Ref # Component Function

1

UL RF QMA ports Connect to the REV RF OUT port on a Prism/Spectrum Host Unit DART.

AIP-CSU-1 UL ports 1, 2, 3, 4, 5, 6, 7, and 8 are populated.

AIP-CSU-2 UL ports 1, 2, 3, 4, 5, and 6 are populated,

AIP-CSU-3 UL ports 1, 2, 5, and 6 are populated,

AIP-CSU-4 UL ports 1, 2, 3, 4, and 5 are populated,

2

DL RF QMA ports Connect to the FWD RF IN port on a Prism/Spectrum Host Unit DART.

AIP-CSU-1 DL ports 1, 2, 3, 4, 5, 6, 7, and 8 are populated.

AIP-CSU-2 DL ports 1, 2, 3, 4, 5, 6, 7, and 8 are populated.

AIP-CSU-3 DL ports 1, 2, 3, 4, 5, 6, 7, and 8 are populated.

AIP-CSU-4 DL ports 1, 2, 3, 4, 5, 6, 7, and 8 are populated.

BIU-1 BIU-2 BIU-3 BIU-4 BIU-5 BIU-6 BIU-7 BIU-8

QMA-1 QMA-2 QMA-3 QMA-4 QMA-5 QMA-6 QMA-7 QMA-8

- UL -

- DL -AIP-CSU

AIP-CSU-1

1

2

BIU-1 BIU-2 BIU-3 BIU-4 BIU-5 BIU-6 BIU-7 BIU-8

QMA-1 QMA-2 QMA-3 QMA-4 QMA-5 QMA-6 QMA-7 QMA-8

- UL -

- DL -AIP-CSU

AIP-CSU-2

2x1 2x1 1

2

BIU-1 BIU-2 BIU-3 BIU-4 BIU-5 BIU-6 BIU-7 BIU-8

QMA-1 QMA-2 QMA-3 QMA-4 QMA-5 QMA-6 QMA-7 QMA-8

- UL -

- DL -AIP-CSU

AIP-CSU-3

3x1 3x1 1

2

BIU-1 BIU-2 BIU-3 BIU-4 BIU-5 BIU-6 BIU-7 BIU-8

QMA-1 QMA-2 QMA-3 QMA-4 QMA-5 QMA-6 QMA-7 QMA-8

- UL -

- DL -AIP-CSU

AIP-CSU-4

4x1 1

2

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 10 ©February 2017 CommScope, Inc.

Page 17: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

AIP Components

Mapping the CSU and BIU Installation and ConnectionsTheCSUispre-configuredatthefactorytomeetDASintegrationrequirements.TheBIUsmustbeinstalledintheslotsthatsupporttheCSUconfiguration.Figure 2-2onpage 12illustratesthefourCSUtraypre-configurations.• Configuration1(AIP-CSU-1)providesastraightthroughpathfortheBIUoutputtotheCSUoutputwithoutanycombining.AtypicalapplicationforthisconfigurationiswhennocombiningofBaseStationfeedsisrequiredorwhereexternalcombiningisdesired.Thisconfigurationprovidesflexibilitytouseexternalcomponentsforcombiningandsplitting.• Configuration2(AIP-CSU-2)containsa2x1powerdividerforBIUslots5and6,andasecond2x1powerdividerforBIUslots7and8.Slots1through4arestraight-throughconnections.The2x1powerdividercombinestheBIUoutputinthedownlinkdirectionandsplitstheBIUinputsignalsintheuplinkdirection.Atypicalapplicationforthisconfigurationiswheninternalcombiningisdesiredtosaverackspaceandflexibilityisnotrequired.ThepowerdividersallowforthecombinationoftwosetsofBaseStationfeedsofthesamefrequency.Asanexample,youcancombinea1900MHzUMTSNodeBwitha1900MHzGSMBaseStation.However,itisimportanttonotethatanycombiningmustbeimplementedwithfrequencyspecificBIUs,asthecombinedsignalsarefedtoabandspecificDAS.Youcanusetheremainingstraight-throughconnectionsforports1through4forcaseswherecombiningisnotrequired.Asanexample,youcandeploy700MIMOinthesamespacewherecombiningofmultiplecarriersisnotrequired.• Configuration3(AIP-CSU-3)containsone3x1powerdividerforBIUports3through5,andasecond3x1powerdividerforports6through8;ports1and2arestraight-thoughconnections.AtypicalapplicationforthisconfigurationissimilartoConfiguration2,withtheexceptionbeingthecombiningofthreeBaseStationfeeds.• Configuration4(AIP-CSU-4)containsjustone4x1powerdividerforcombiningBIUports5through8,whileBIUports1through4remainasstraight-throughconnections.ThistypicalapplicationissimilartoConfiguration2andConfiguration3.CAUTION! For configurations 2, 3, and 4, any combining must be implemented with band specific BIUs. Also, for

any power divider port not used with a BIU slot, this slot must be filled with a Termination BIU Module that contains a 50 Ohm termination. All power divider ports must be terminated either with a band-specific BIU or a Termination BIU Module for optimal performance.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 11

Page 18: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

AIP Components

Figure 2-2. CSU Tray Configurations

Configura�on 1 (AIP-CSU-1) Configura�on 2 (AIP-CSU-2)

Configura�on 3 (AIP-CSU-3) Configura�on 4 (AIP-CSU-4)

Terminated

Terminated

Terminated

Terminated

Terminated

Terminated

Terminated

Terminated

Terminated

2x1

2x1

4x13x1

3x1

Port 8Port 7Port 6

Port 5

Port 4Port 3Port 2Port 1

Port 8Port 7Port 6

Port 5

Port 4Port 3Port 2Port 1

Port 8Port 7

Port 6

Port 5

Port 4Port 3Port 2Port 1

Port 8Port 7

Port 6

Port 5

Port 4Port 3Port 2Port 1

Slot 8Slot 7Slot 6

Slot 5

Slot 4Slot 3Slot 2Slot 1

Slot 8Slot 7

Slot 6

Slot 5

Slot 4Slot 3Slot 2Slot 1

Slot 8Slot 7Slot 6

Slot 5

Slot 4Slot 3Slot 2Slot 1

Slot 8Slot 7

Slot 6

Slot 5

Slot 4Slot 3Slot 2Slot 1

BIU(RF Module)Slot #s

CSU UL/DLPort #s

CSU UL/DLPort #s

CSU UL/DLPort #s

CSU UL/DLPort #s

QMA QMA

QMA QMA

BIU(RF Module)Slot #s

BIU(RF Module)Slot #s

BIU(RF Module)Slot #s

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 12 ©February 2017 CommScope, Inc.

Page 19: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

AIP Components

Figure 2-3showshowtheBIUslotsandtheCSUQMAportsarenumbered.

Figure 2-3. BIU Slot and CSU QMA Port Numbering Scheme

Fan ModulesTheAIPfansystemhasfourfansthatprovideforced-airventilationtotheAIPchassisandallinstalledunits.Airflowisfromthefrontofthechassistotherear.

CSUQMAPort 1

CSUQMAPort 8

BIUSlot 1

BIUSlot 8

BIU-1 BIU-2 BIU-3 BIU-4 BIU-5 BIU-6 BIU-7 BIU-8

QMA-1 QMA-2 QMA-3 QMA-4 QMA-5 QMA-6 QMA-7 QMA-8

- UL -

- DL -AIP-CSU-01

Status

Power

EXPANSION1

EXPANSION2

CRAFT

ADMIN/LAN

48 V5 A, max

+

AIP-ACU

Status

Power

AIP-BIU

BTSTx/Rx

Sample Port

Status

Power

AIP-BIU

BTSTx/Rx

Sample Port

Status

Power

AIP-BIU

BTSTx/Rx

Sample Port

Status

Power

AIP-BIU

BTSTx/Rx

Sample Port

Status

Power

AIP-BIU

BTSTx/Rx

Sample Port

Status

Power

AIP-BIU

BTSTx/Rx

Sample Port

Status

Power

AIP-BIU

BTSTx/Rx

Sample Port

Status

Power

AIP-BIU

BTSTx/Rx

Sample Port

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 13

Page 20: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

AIP Components

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 14 ©February 2017 CommScope, Inc.

Page 21: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Chapter Topics Page

Prepare for Installation ............................................................................................................................................................................................14Install the AIP Safely .........................................................................................................................................................................................14Guard against Damage from Electro-Static Discharge .....................................................................................................................................14Unpack and Inspect the AIP Chassis and Modules ...........................................................................................................................................14

Install the AIP Chassis in an Equipment Rack ...........................................................................................................................................................15Determine the Mounting Method....................................................................................................................................................................15Removing the Factory Installed Mounting Ears ...............................................................................................................................................16Mounting the AIP in a Two-Post Rack ..............................................................................................................................................................17Mounting the AIP in a Four-Post Rack..............................................................................................................................................................19Securing the AIP Chassis to the Equipment Rack .............................................................................................................................................20

Ground the AIP Chassis ............................................................................................................................................................................................21Install Power Wiring .................................................................................................................................................................................................22Install the CSU Tray ..................................................................................................................................................................................................24Install the BIU(s) .......................................................................................................................................................................................................25Connect the BIU to the BTS ......................................................................................................................................................................................26Connect the CSU.......................................................................................................................................................................................................27

Connect the CSU to a Prism/Spectrum Host Unit ............................................................................................................................................27Connect the CSU to a Fusion Main Hub ...........................................................................................................................................................29

ThischaptertellsyouhowtoinstalltheAIPintoanequipmentrack,installtheAIPACU,BIU,andCSUmodules,wiretheAIPforpower,andconnecttheAIPfortransmittingandreceivingRF.NOTE: This chapter describes how to install a basic AIP. If you are installing an AIP with an External Combiner/

Splitter Shelf (ECSS), follow the steps in "Using an External Combiner/Splitter Shelf” on page 137.

INSTALLING THE AIP 3

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 15

Page 22: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Prepare for Installation

PREPARE FOR INSTALLATION

Install the AIP Safely

CAUTION! This is restricted access equipment. You should only install an AIP in a Network Telecommunications Facility, and only qualified service personnel should service and operate this equipment using appropriate tools.

CAUTION! Wet conditions increase the potential for receiving an electrical shock when installing or using electrically powered equipment. To prevent electrical shock, never install or use electrical equipment in a wet location or during a lightning storm.

CAUTION! The maximum ambient temperature for the AIP is 50° C (122° F).

Guard against Damage from Electro-Static Discharge

CAUTION! Electro-Static Discharge (ESD) can damage electronic components. To prevent ESD damage, always wear an ESD wrist strap when working with this unit or when handling any of its components. Connect the ground wire on the ESD wrist strap to an earth ground source before touching this unit or any of its components. Wear the wrist strap the entire time that you work with the unit and its components.

CAUTION! Place unit components in anti-static packing material when transporting or storing them.

Unpack and Inspect the AIP Chassis and Modules1 Opentheshippingcartonandcarefullyunpackthepartsfromtheirprotectivepackaging.NOTE: The AIP-HU-1 Chassis and AIP-CU-1 Control Unit ship together in a master box. The AIP-CU-1 unit is in

an individual box within the master box to protect it from damage.

2 Checktheunitforbrokenormissingparts.Ifthereareanydamages,contactCommScopeforanRMA(ReturnMaterialAuthorization)andtoreorderifreplacementisrequired(see"ContactingGlobalTechnicalSupport”onpage 156).

Table 3-1. AIP Parts List

NAME DESCRIPTION QTY

AIP-HU-1 Chassis 1

Mounting Ear 1.5mm thick, cold rolled steel mounting ear 2

M4x5 screw Stainless steel M4x5 304 flat-head screws 4

Rack Screw, 10-32x3/4” Truss head rack screws 16

Copper Ground Lug Two-hole copper ground lug, standard barrel 1

AIP-CU-1 Control Unit 1

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 16 ©February 2017 CommScope, Inc.

Page 23: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Install the AIP Chassis in an Equipment Rack

INSTALL THE AIP CHASSIS IN AN EQUIPMENT RACK

TheAIPchassisrequires6RUofspace,andrequiresatleast3"ofcablespaceaboveorbelowthechassistoprovidefortheroutingofcoaxialcablestotheBIU.CAUTION! A fully loaded AIP can weigh more than 100 pounds; install the AIP chassis into the equipment rack

before installing its modules.

CAUTION! When loading the AIP in a rack, make sure the mechanical loading of the rack is even to avoid a hazardous condition such as an unbalanced rack.

CAUTION! The rack should safely support the combined weight of all the equipment it holds.

Determine the Mounting MethodUsetheinformationonthechassis’weightanddimensionsin"TechnicalSpecifications”onpage 151todeterminethebestmountingoptionforyoursite.Mountingoptionsareasfollows:• MountingtheAIPinaTwo-PostRack—tomounttheAIPinatwo-postrack,youuseonesetofmountingearsinthemidposition.Themountingearscanbeforwardorrearfacing.• MountingtheAIPinaFour-PostRack—therearetwooptionsformountingtheAIPinafour-postrack.

– Youcaninstallfront-to-backhorizontalrailsintheequipmentrackanduseonesetofmountingearsinthefrontposition.Themountingearscanbeforwardorrearfacing.– Youcaninstallatelescopingshelfintheequipmentrackanduseonesetofmountingearsinthefrontposition.Themountingearscanbeforwardorrearfacing.

NOTE: The AIP chassis requires 6 RU of space. A telescoping rack adds an additional 1 RU to the AIP installation, for a total of 7 RU of space.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 17

Page 24: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Install the AIP Chassis in an Equipment Rack

Removing the Factory Installed Mounting EarsYouonlyneedtoremovethefactoryinstalledmountingearsifyouneedtofliptheearsintoarear-facingpositionoriftheinstallationrequiresthemountingearstobeinthemiddlepositionoftheAIPchassis.1 Removethefivescrewsthatsecureeachpre-installedmountingeartotheAIP.

2 RemovethetwoscrewsthatsecuretheAIPhandletothechassis,andthenremovetheAIPhandle.

Two M4x5 flat-head screwsThree M4x10 screws

Moun�ng ear in front posi�on, forward facing

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 18 ©February 2017 CommScope, Inc.

Page 25: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Install the AIP Chassis in an Equipment Rack

Mounting the AIP in a Two-Post Rack1 Followthestepsin"RemovingtheFactoryInstalledMountingEars”onpage 18.2 RemovethreeM4x10screwsfromtheAIPchassisasshownbelow;savethescrewsforreuse.

Three M4x10 head screws

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 19

Page 26: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Install the AIP Chassis in an Equipment Rack

3 UsethefollowingillustrationtoseethetypeandquantityofscrewsrequiredtoattachamountingbrackettothemiddlepositionoftheAIPchassis.ThemountingearscanfacethefrontortherearoftheAIPchassis.

4 Followthestepsin"SecuringtheAIPChassistotheEquipmentRack”onpage 22.

Three M4x10 screws Two M4x5 flat-head screws

Moun�ng ear, shown in rear-facing posi�on

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 20 ©February 2017 CommScope, Inc.

Page 27: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Install the AIP Chassis in an Equipment Rack

Mounting the AIP in a Four-Post Rack1 InstalloneofthefollowingintheequipmentrackinthelocationinwhichyouwillinstalltheAIP:

• twohorizontalrails,fromthefrontrailtothebackrailoftheequipmentrack,sotheywillrunalongeachsideoftheAIPchassis• atelescopingracktosupporttheweightoftheAIPchassis.

NOTE: The AIP chassis requires 6 RU of space. A telescoping rack adds an additional 1 RU to the AIP installation, for a total of 7 RU of space.

2 Ifthemountingbracketsneedtoberearfacing,completethestepsin"RemovingtheFactoryInstalledMountingEars”onpage 18.3 UsethefollowingillustrationtoseethetypeandquantityofscrewsrequiredtoattachmountingbracketstothefrontpositionoftheAIPchassis.ThemountingearscanfacethefrontortherearoftheAIPchassis.

4 Followthestepsin"SecuringtheAIPChassistotheEquipmentRack”onpage 22.

Two M4x5 flat-head screwsThree M4x10 screws

Moun�ng ear in front posi�on, forward facing

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 21

Page 28: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Install the AIP Chassis in an Equipment Rack

Securing the AIP Chassis to the Equipment Rack1 PositiontheAIPinanavailablespaceintherack;allowforatleast3"ofcablespaceaboveorbelowtheAIPchassistoprovidefortheroutingofcoaxialcablestotheBIU.2 Useeight10-32x3/4”TrussheadrackscrewsthatshippedwiththeAIPchassistoattachtheAIPtotheequipmentrack(fourscrewsoneachside).Thefollowingillustrationshowsthelocationoftherack-mountingholesforthefrontandmiddlemountingpositions.

Rack-moun�ng holes on moun�ng brackets

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 22 ©February 2017 CommScope, Inc.

Page 29: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Ground the AIP Chassis

GROUND THE AIP CHASSIS CAUTION! Maintain reliable grounding. Pay particular attention to ground source connections. Route the

grounding wire to an approved earth ground source.

CAUTION! The AIP must be bonded to an Isolated Bonding Network (IBN).

NOTE: The chassis ground stud is the only connection point on the AIP that is on the back of the AIP chassis.

1 Locatethetwo-holecoppergroundlugthatshippedwiththeAIP.2 Obtainalengthof#8AWG(3.26mm)insulatedstrandedcopperwireforuseasachassisgroundingwire.3 Terminateoneendofthewirewiththetwo-holelugthatshippedwiththeAIPchassis.4 LocatethechassisgroundstudsattherearoftheAIP.5 Asshowntotheright,dothefollowing:

• Placeastarwasheroverbothstuds.• Loopthetwo-holelugoverthechassisgroundstuds.• Placeasecondstarwasheroverbothstuds,ontopofthetwo-holelug.• Placeahexnutoverbothstarwashers,andthenhandtighten.

6 Routethefreeendofthechassisgroundingwiretoanapprovedearthgroundsource(perlocalcodeorpractice).

Rear of AIP

Chassis-groundstuds

Starwashers

Hexnuts

Ground wire

Two-hole lug

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 23

Page 30: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Install Power Wiring

INSTALL POWER WIRING

TheAIPispoweredbynominal48Vdc(OperatingRangeis40-56V),whichisfedtotheAIPthroughafourpositionterminalblocklocatedontheAIPACUfaceplate.PowertotheAIPcanbesuppliedthroughafusepanel,suchasthe20positionPowerWorxGMTFusePanel(availableseparately).CAUTION! Protect each AIP with a separate fuse.

CAUTION! Protect the power with a 5-AMP GMT fuse for 48 Vdc.

CAUTION! Terminate the input power return as DC-I (Isolated).Table3-2liststheAIPpowerconsumptionforafullyloadedAIPchassis,andTable 3-3liststheacceptable48Vdcwiresizes.

DothefollowingtoconnecttheAIPtoafusepanel:1 Obtaintheitemslistedbelow:

• Wirestripperandscrewdriver• Wire,#18AWG(1.00mm)redandblackinsulatedcopperwire.Recommendedwiresizeforthepowerleads,whenfusedinthesamebay.

2 Connectthewirestothedesignatedterminalsonthefusepanel.3 Dressandsecurethewirestotherackfollowinglocalpractice.Routewiringawayfromsharpedgesandsecureinplacetopreventchaffingandprovidestrainrelief.NOTE: Secure wires to the relay rack with lacing cord per local practice, ensuring to wrap protective covering

such as fish paper where lacing cord is used.

Table 3-2. AIP Power Consumption for a Fully Loaded AIP Chassis

Volts(V) Watts (W) Current (A)

40 120* 3

48 120* 2.5

56 120* 2.2

* 10 Watts/1 BIU; 80 Watts/8 BIUs

Table 3-3. 48 Vdc Wire Sizes

Recommended Wire Size Range

Current (A)

AWG 23~144.7~32

mm2 0.6~1.5

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 24 ©February 2017 CommScope, Inc.

Page 31: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Install Power Wiring

4 RoutethewirestotheterminalblockontheAIPACUandcutthemtolength,allowingsufficientlengthfortermination.5 Strip0.5inch(1.27cm)ofinsulationfromtheendofeachwire.6 Insertoneendofeachwireintotheterminalblock.

• Ina+48Vdcplant,thehighestpotentialisthe+48lead.Ina+48Vdcplant:– connectthe+48leadtothepositive(+)connector– connectthe0potential(groundorreturn)tothenegative(-)connector.

• Ina-48Vdcplant,thehighestpotentialisthe0(groundorreturn)lead.Ina-48Vdcplant:– connectthe0(groundorreturn)leadtothepositive(+)connector– connectthe-48Vdcleadtothenegative(-)connector.

7 Inserttheterminalblockintothe4-pinreceptacleontheAIPACU.8 Installfusesinthefusepanel.Updateofficerecordsasrequired.CAUTION! When connecting the equipment to the supply

circuit, check equipment nameplate ratings to avoid overloading circuits, which may cause damage to over-current protection devices and supply wiring.

9 CheckthattheACUPowerLEDisgreen(see"AIPControlUnit”onpage 8).CAUTION! At this time the ACU and the AIP chassis are receiving power. As you continue to install the AIP

components, continue to follow the information in"Install the AIP Safely” on page 16 and "Guard against Damage from Electro-Static Discharge” on page 16.

Status

Power

EXPANSION1

EXPANSION2

CRAFT

ADMIN/LAN

48 V5 A, max

+

AIP-ACU

Highest poten�al

Lowest poten�al

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 25

Page 32: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Install the CSU Tray

INSTALL THE CSU TRAY

1 SlidetheCSUintotheAIPchassisandseatitfirmlyinitsslot.2 TightenthetwothumbscrewsthatsecuretheCSUtotheAIPchassis.3 VerifythattheCSUPowerLEDisgreen.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 26 ©February 2017 CommScope, Inc.

Page 33: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Install the BIU(s)

INSTALL THE BIU(S)DothefollowingtoinstalltheBIU(s)intotheAIPchassis:1 ToensureyouareinstallingthecorrectBIUinthecorrectslot,referto"MappingtheCSUandBIUInstallationandConnections”onpage 11.2 UseFigure 2-2onpage 12todeterminetheslotinwhichtoinstalltheBIU.3 Ifthisisnotaninitialinstall,youmayhavetoremoveaTerminationBIUModuleorblankfaceplatefromtheslotinwhichyouwanttoinstalltheBIU.4 SlidetheBIUintotheAIPchassisandseatitfirmlyinitsslot.5 TightenthefourthumbscrewsthatsecuretheBIUtotheAIPchassis.6 RepeatthisprocedureuntilallBIUsrequiredtosupporttheCSUconfigurationareinstalled.7 Dooneofthefollowing,asapplicabletothisinstallation.

• InstallTerminationBIUModulesinanyunusedslotsfeedingintotheCSUs2x1,3x1,or4x1combiner/splittercomponent.• Installastandardblankfaceplatetosealtheemptyslots.

CAUTION! To ensure proper air flow across heatsinks and to keep debris out of the AIP chassis, you must install blank faceplates or Termination BIU Modules.

CAUTION! For configurations 2, 3, and 4, any combining must be implemented with band specific BIUs. Also, for any unused slots feeding into a CSUs 2x1, 3x1, or 4x1 combiner/splitter component, fill the unused slot with a Termination BIU Module that contains a 50 Ohm termination.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 27

Page 34: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Connect the BIU to the BTS

CONNECT THE BIU TO THE BTS1 Obtaintherequiredlengthoffeedercablewitha7/16DINconnector(fromtheAIPBIUtotheBTS).2 AttheBTS,removethedustcapfromtheTx/Rxconnector,andthecapfromthefeedercable's7/16DINconnector.3 CleantheTx/Rxconnectorandthefeedercable's7/16DINconnector(followthe7/16DINconnectorsupplier'srecommendations).4 Connectthefeedercable's7/16DINconnectortotheTx/RxconnectorontheBTS.5 RoutethefeedercablebetweentheBTSandtheAIPBIU(persystemdesignplan).AllowsufficientslackfordressingandorganizingcablesattheAIP.6 AttheAIP,removethedustcapfromtheBIUBTSTx/Rxconnector,andthecapfromthefeedercable's7/16DINconnector.7 CleantheBTSTx/Rxconnectorandthefeedercable's7/16DINconnector(followtherecommendationsofthe7/16DINconnectormanufacturer).8 Connectthefeedercable's7/16DINconnectortotheBIUTx/Rxconnector.9 DressandsecurecablestothesideoftheAIPchassis.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 28 ©February 2017 CommScope, Inc.

Page 35: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Connect the CSU

CONNECT THE CSUFollowtheprocedurethatsupportstheDASsysteminwhichyouareinstallingtheAIP:• "ConnecttheCSUtoaPrism/SpectrumHostUnit”onpage 29• "ConnecttheCSUtoaFusionMainHub”onpage 31.NOTE: If the system that you are installing requires an External Combiner/Splitter Shelf (ECSS), follow the steps

in "Using an External Combiner/Splitter Shelf” on page 137.

Connect the CSU to a Prism/Spectrum Host UnitForaPrismorSpectruminstallation,youconnecttheAIPCSUtoaPrismorSpectrumHostUnit,viatheHostUnitDART(s).TwoQMAfemaleportssupporttheRFinterfacebetweentheHostDARTModulesandtheCSU—oneforthedownlinksignal(forwardpath),andtheotherfortheuplinksignal(reversepath).1 Obtaintherequiredlengthsofhighperformance,flexible,lowloss50-ohmcoaxialcommunicationscable(RG-400orequivalent)forallcoaxialconnections.2 RouteforwardandreversepathcoaxialcablebetweentheHostUnitandtheAIPCSU(persystemdesignplan),andthencutthecabletoitsrequiredlength.AllowsufficientslackfordressingandorganizingcablesattheHostUnit.3 TerminateeachcablewithaQMA-Typemaleconnectorfollowingtheconnectorsupplier’srecommendations.4 RefertoFigure 2-2onpage 12andFigure 2-3onpage 13todeterminewhichQMAportontheCSUtoconnecttotheHostUnitDART.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 29

Page 36: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Connect the CSU

5 ForeachBIUinstalledintheAIP,connecttheforwardandreversepathcables,asdescribedbelow.a ConnecttheCSUQMAULporttotheREVRFOUTconnectoronaHostDARTfrontpanel.b ConnecttheCSUQMADLporttotheFWDRFINconnectoronaHostDARTfrontpanel.

6 DressandsecurecablestotherightsideofthePrism/SpectrumHostUnit.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 30 ©February 2017 CommScope, Inc.

Page 37: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Connect the CSU

Connect the CSU to a Fusion Main Hub1 Obtaintherequiredlengthsofhighperformance,flexible,lowloss50-ohmcoaxialcommunicationscable(RG-400orequivalent)forallcoaxialconnections.2 RouteforwardandreversepathcoaxialcablebetweentheFusionMainHubandtheAIPCSU(persystemdesignplan),andthencutthecabletoitsrequiredlength.AllowsufficientslackfordressingandorganizingcablesattheFusionMainHub.3 TerminateeachcablewithaQMA-Typemaleconnectorfollowingtheconnectorsupplier’srecommendations.4 RefertoFigure 2-2onpage 12andFigure 2-3onpage 13todeterminewhichQMAportontheCSUtoconnecttotheFusionMainHub.5 ForeachBIUinstalledintheAIP,connecttheforwardandreversepathcables,asdescribedbelow.

a ConnecttheCSUQMAULporttoanUPLINKNconnectorontheFusionMainHub.b ConnecttheCSUQMADLporttoaDOWNLINKNconnectorontheFusionMainHub.

Alarms AC Power

Band 1 Band 2 Band 3

UL1 UL2 UL3

DL1 DL2 DL3

Uplink N connectors

Downlink N connectors

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 31

Page 38: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Connect the CSU

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 32 ©February 2017 CommScope, Inc.

Page 39: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Chapter Topics Page

Following the EMS Procedures in this Guide............................................................................................................................................................33Using the GUI Components ......................................................................................................................................................................................34

Tab Frame.........................................................................................................................................................................................................35System Tree......................................................................................................................................................................................................36

Web Browser Requirements and Setup ...................................................................................................................................................................37Access the AIP EMS for the First Time......................................................................................................................................................................41Set the Network Connections ..................................................................................................................................................................................43

Set Network Connections Automatically..........................................................................................................................................................43Set Network Connections Manually .................................................................................................................................................................45

Synchronize AIP Date and Time with an NTP Server ................................................................................................................................................46Set the System Information......................................................................................................................................................................................47

Set the System Name .......................................................................................................................................................................................47Configure an AIP...............................................................................................................................................................................................48Label an Individual Main or Secondary AIP ......................................................................................................................................................49

Label an AIP Option 1 ...............................................................................................................................................................................49Label an AIP Option 2 ...............................................................................................................................................................................50

Label an ACU ....................................................................................................................................................................................................50Label an ACU Option 1..............................................................................................................................................................................50Label an ACU Option 2..............................................................................................................................................................................51

Label a CSU .......................................................................................................................................................................................................51Label a CSU Option 1 ................................................................................................................................................................................52Label a CSU Option 2 ................................................................................................................................................................................52

Set Up SNMP ............................................................................................................................................................................................................53Set Up SNMP Trap Managers ...................................................................................................................................................................................54Deleting an SNMP Trap Manager .............................................................................................................................................................................57Modifying an SNMP Trap Manager ..........................................................................................................................................................................59Calibrate the CSU with the BIUs ...............................................................................................................................................................................60Managing BIUs .........................................................................................................................................................................................................65

Getting BIU Information ...................................................................................................................................................................................65Getting Information about Bands ....................................................................................................................................................................66Configuring BIUs ...............................................................................................................................................................................................67

Changing the Configuration of a BIU ........................................................................................................................................................68BIU Configuration Parameters..................................................................................................................................................................70

Using Diagnostic Tones.....................................................................................................................................................................................73Backing up BIU Configurations .........................................................................................................................................................................75Restoring a Backed Up BIU Configuration ........................................................................................................................................................76Exporting a BIU Configuration File to a PC .......................................................................................................................................................78Importing and Restoring a BIU Backup File from a PC .....................................................................................................................................80Deleting a Backed Up BIU Configuration..........................................................................................................................................................81Deleting a BIU from the AIP System Setup.......................................................................................................................................................83

Option 1: Deleting a BIU from the AIP System Setup...............................................................................................................................83Option 2: Deleting a BIU from the AIP System Setup...............................................................................................................................84

Resetting AIP Components to Factory Default Settings ...................................................................................................................................85Getting System Information.....................................................................................................................................................................................87

Get System Information for All AIPs.................................................................................................................................................................87Get ACU Information........................................................................................................................................................................................89Get CSU Information ........................................................................................................................................................................................90

Rebooting an ACU ....................................................................................................................................................................................................91Troubleshooting NTP Server Errors..........................................................................................................................................................................92Running a Self Mapping Test on a CSU.....................................................................................................................................................................94

USING THE AIP ELEMENT MANAGEMENT SOFTWARE

4

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 33

Page 40: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Viewing Alarms.........................................................................................................................................................................................................95Alarm Indicators ...............................................................................................................................................................................................95Viewing Alarm Details on an ACU or CSU Get Information Page .....................................................................................................................96Viewing BIU Alarm Details................................................................................................................................................................................98View Current Alarms ......................................................................................................................................................................................100View an Alarm History....................................................................................................................................................................................102

Filtering the View History Table .............................................................................................................................................................103Exporting an Alarm History ....................................................................................................................................................................105

Clearing the Alarm History .............................................................................................................................................................................108Clearing Disconnect Alarms....................................................................................................................................................................................109Upgrading an AIP System .......................................................................................................................................................................................110Using a Static IP Address for the Main AIP Craft Port ............................................................................................................................................111Managing Users......................................................................................................................................................................................................114

Viewing Users .................................................................................................................................................................................................114Add a New User..............................................................................................................................................................................................115Delete a User ..................................................................................................................................................................................................117Change the Password of another User...........................................................................................................................................................118Changing Your Own Password........................................................................................................................................................................119

Viewing the AIP EMS Release Information.............................................................................................................................................................120Logging Out of the AIP............................................................................................................................................................................................121Alarm Reference.....................................................................................................................................................................................................122

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 34 ©February 2017 CommScope, Inc.

Page 41: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Following the EMS Procedures in this Guide

FOLLOWING THE EMS PROCEDURES IN THIS GUIDE

TheinformationinthischapterguidesyouthroughprovisioningaCommScopeAIPthroughitsweb-basedElementManagementSoftware(EMS).TheorderoftopicsisintheorderinwhichyoushouldprovisionanAIP.MostoftheEMSproceduresinthisdocumentassumethatyouhavealreadyloggedintotheEMSasdescribedin"AccesstheAIPEMSfortheFirstTime”onpage 43.Ingeneral,theproceduresinthisdocumentendbyhavingyouclickApplytoacceptchangesorinput.(TheApplybuttonturnsredwhenaparameterhasbeenchangedbuthasnotyetbeenapplied(executed).OnceyouclickApply,thebuttoncolorrevertstoblack.)Whenanoperationcompletes,anApply successfulmessage,suchasthemessageshowninFigure4-1,willdisplay.Ifanerrormessagedisplays,followthescreenprompts.(Thetextofthemessagecorrespondstothecommandthatwasexecuted.)

Figure 4-1. Operation Completed MessageAlso,whenaprocedurerequiresthatyouselectasequenceofmenuitems,aright-anglequote(>)separatestheitems.Forexample,inthefollowinggraphic,“clickSystem Configuration >Set Network Connections”indicatesthatintheSystemMenubaryouselectSystem Configuration,andthenintheSystem Configurationmenu,selectSet Network Connections.Youwillfindthefollowingfontconventionsinusethroughoutthischapter.• This fontrepresentsareferencetoanEMSdialogbox,menuitem,configurationoption,orotherparameter.• This fontrepresentsnon-variabletextthatyoutypeataprompt.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 35

Page 42: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Using the GUI Components

USING THE GUI COMPONENTS

YouusetheInternetExplorerwebbrowsertoaccesstheEMSGraphicalUserInterface(GUI)showninFigure 4-2anddescribedinTable 4-1.

Figure 4-2. EMS Graphical User Interface

Table 4-1. GUI Components

ID # Component Description

1 Tab Frame See "Tab Frame” on page 37.

2 Orientation links Provides links that allow you to navigate within the GUI:• Home—returns you to the Home page• Logout—logs you out of the EMS.

3 Operational buttons

• Apply—applies your configuration changes without closing the dialog. The Apply button turns red when a parameter has been changed but has not yet been applied (executed). Once you click Apply, the button color reverts to black.

• Done—closes a dialog box.• Refresh—updates status information to reflect current conditions.

4 Unit Identifier Identifies which system component is selected in the System Tree.

5 System Tree See "System Tree” on page 38.

6 System Menu bar Provides access to menus that allow you to configure or view system settings and alarms.

1

3

2

4

5

6

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 36 ©February 2017 CommScope, Inc.

Page 43: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Using the GUI Components

Tab FrameTheTabFrameprovidestheworkspaceinwhichyouaccessaAIPEMSwebpagespecifictoaunitorfunction;itprovidestheparametersandmessagesspecifictotheunitselectedintheSystemTreeandspecifictotheselectedmenu.ThenameofthetabcorrespondstotheitemselectedintheSystemMenubar.Figure 4-3describesthedifferentelementsfoundwithintheEMSTabFrame.NOTE: The Tab Frame updates its contents approximately every 20 seconds.

Figure 4-3. Elements within a Tab Frame

ID # Element Description

1 Tab Frame title The Tab Frame title corresponds to the menu path. In Figure 4-3, you would have clicked System Configuration > Set SNMP Trap to open this Tab Frame.

2 Icon buttons Click on an Icon button to access additional parameters that allow you to perform the operation associated with the name of the Icon button.

3 Table Tables organize system content into columns and rows. The table in a Tab Frame corresponds to the title of the frame.

4 Panel A panel is a grouping of fields or parameters, with the panel title in the upper-left corner.

5 Text box A text box allows you to enter custom information for the corresponding field.

6 Radio button Click on a Radio button to select or deselect an option. When a Radio button is selected, the round “button” is black (filled in). When a Radio button is deselected, it is white (not filled in).

7 Operational buttons Execute the command for which the button is labeled. When a button is grayed out, that function is not available. If the text on the Apply button is red, you have not yet applied the changes made in the open GUI page.

1

2

3

4

5

6

7

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 37

Page 44: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Using the GUI Components

System TreeTheSystemTreedisplaysanAIPanditscomponentsasuniticonswithinahierarchicaltree.YouclickonanodetonavigatetoawebpagewithintheEMSTabFramethatcorrespondstotheselectedunitormodule.Table 4-2. System Tree Icons

Icon Description

Click to refresh the System Tree.

Click to force a rediscovery of all modules in the AIP system or in a cascade.

CAUTION! Only click on this icon to recover from a major reconfiguration of the system.• If you select the top AIP icon in the System Tree and then click the Rediscovery button, the AIP is deleted

from the System Tree, and the system forces a rediscovery of all modules in the selected AIP or the cascade.

• If you select a BIU in the System Tree and then click the Rediscovery button, all BIUs will be deleted from the System Tree and the AIP will rediscover any BIUs installed in the chassis. This Rediscovery function takes several minutes to complete and there will not be any indication that this operation is occurring. CSU calibration is also lost and must be run again (see "Calibrate the CSU with the BIUs” on page 62).

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 38 ©February 2017 CommScope, Inc.

Page 45: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Web Browser Requirements and Setup

WEB BROWSER REQUIREMENTS AND SETUP

TheAIPEMSinteractiveGUIrequiresthatyouuseInternetExplorerVersion8orlaterasyourwebbrowser.TheAIPEMSwillnotworkwithotherbrowsers.DothefollowingtoprepareyourInternetExplorerbrowserforusewithanAIPsystem.1 MakesureyouhaveAdobeShockwavePlayerinstalledonyourPC.Ifnecessary,youcandownloadthisplug-inapplicationforfreefromtheAdobewebsite.2 OpenInternetExplorerVersion8orlater.3 ClickTools > Internet Options.TheInternet Options dialogopens.4 UnderBrowsing history,selectDelete browsing history on exit,andthenclickSettings.

TheTemporary Internet Files and History Settingsdialogopens.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 39

Page 46: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Web Browser Requirements and Setup

5 UnderCheck for newer version of shared pages,selectEvery time I visit the webpage,andthenclickOK.

TheTemporary Internet Files and History Settingsdialogcloses.6 Dooneofthefollowingtoturnoffthepopupblocker:

• ForInternetExplorerVersion8,clickTools > Pop-up Blocker > Turn Off Pop-Up Blocker.• ForInternetExplorerVersion9,dothefollowing,(andasshowninthegraphictotheright):

i InInternetExplorer,Tools > Internet Options.ii IntheInternet Optionsdialog,clickthePrivacytab,andthenunderPop-up Blocker,makesureTurn on Pop-up

Blockerisnotselected.iii ClickApply.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 40 ©February 2017 CommScope, Inc.

Page 47: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Web Browser Requirements and Setup

7 ClicktheSecuritytab,selectTrusted sites,andthenclickSites.

TheTrusted sitesdialogopens.

8 UnderAdd this website to the zone,addtheIPaddressfortheAIPsystem(192.168.2.1),andthenclickAdd.

9 ClickClose.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 41

Page 48: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Web Browser Requirements and Setup

10 IntheInternet Optionsdialog,clickOK;thisappliesallofthechangesmadetoInternetExplorerinthisprocedure.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 42 ©February 2017 CommScope, Inc.

Page 49: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Access the AIP EMS for the First Time

ACCESS THE AIP EMS FOR THE FIRST TIME

ThefollowinginstructionsareforaccessingaMainAIPforthefirsttime.IfyouaresettingupaSecondaryAIPwithinacascade,followthestepsin"WorkingwithCascadedAIPs”onpage 123.DothefollowingtoaccessaMainAIPforaninitialinstallation.1 Completethestepsin"WebBrowserRequirementsandSetup”onpage 39.2 UseanEthernetCAT5cable(straightorcrossover)toconnectalaptoptotheCraftportontheACU.

3 ConfigureyourcomputerforDHCPnetworking.4 Logintoyourcomputer,andthenopenInternetExplorerVersion8orlater.5 IntheIEWebAddressbox,enterthefollowingURL:https://192.168.2.1NOTE: If you prefer to use a static IP, follow the steps in "Using a Static IP Address for the Main AIP Craft Port”

on page 113.

Status

Power

EXPANSION1

EXPANSION2

CRAFT

ADMIN/LAN

48 V5 A, max

+

AIP-ACU

Cra�port

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 43

Page 50: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Access the AIP EMS for the First Time

6 WhentheAIP EMS Login windowopens:a IntheUser Namebox,typetheusernameprovidedbyCommScopeorbytheNetworkAdministrator.Thedefaultusernameisadmin.b InthePasswordbox,typethepasswordprovidedbyCommScopeorbytheNetworkAdministrator.Thedefaultpasswordisadmin.

c ClickLogin.TheAIPEMSopenstotheGet Informationpage,whichisthedefaultview.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 44 ©February 2017 CommScope, Inc.

Page 51: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Set the Network Connections

SET THE NETWORK CONNECTIONS

YoucanasktheAIPEMStosetupthenetworkconnectionsautomatically,oryoucansetthemmanually.Gotothesectionthatappliestohowyouwanttosetupthenetworkconnections:• “SetNetworkConnectionsAutomatically”• “SetNetworkConnectionsManually.”

Set Network Connections Automatically1 ConnectanEthernetCAT5cable(straightorcrossover)fromtheACUADMIN/LANconnectortoyourmainnetwork.

2 IntheSystemMenubar,clickSystem Configuration > Set Network Connection.3 Selectthefollowingoptions:

• Obtain an IP address automatically• Obtain DNS server automatically

Status

Power

EXPANSION1

EXPANSION2

CRAFT

ADMIN/LAN

48 V5 A, max

+

AIP-ACU

Cra� port connected to PC

ADMIN/LAN port connectedto main network

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 45

Page 52: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Set the Network Connections

4 ClickApply.TheAIPEMSdeterminesifthisisanIPv4orIPv6setup,andthenautomaticallyassignstheIP Address,Subnet Mask,Gateway,andDNS.

NOTE: The AIP network addresses will be read-only when assigned automatically by the network.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 46 ©February 2017 CommScope, Inc.

Page 53: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Set the Network Connections

Set Network Connections Manually

CAUTION! Do not set the IP address of the ACU ADMIN/LAN port within the same subnet as the IP address for the Craft port (192.168.0.x or 192.168.2.x), as this causes the ADMIN/LAN port to stop working.

1 IntheSystemMenubar,clickSystem Configuration > Set Network Connection.2 Ifnecessary,deselectthefollowingoptions:

• Obtain an IP address automatically• Obtain DNS server automatically

3 UsethetextboxesintheSet Network ConnectionpagetoenterthenetworkconnectionsforthisAIP,entertheconnectionsinthexxx.xxx.xxx.xxxformat.SettheoptionsforeitherIPv4orIPv6,dependentonlocalpracticeorrequirements.• IPv4

– IP Address– Subnet Mask– Gateway– DNS.

• IPv6– IP address– Subnet Prefix Length(normally64,butcanbebetween48and64)– Gateway– DNS.

4 ClickApply.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 47

Page 54: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Synchronize AIP Date and Time with an NTP Server

SYNCHRONIZE AIP DATE AND TIME WITH AN NTP SERVER

TheAIPautomaticallytriestoconnecttoaNetworkTimeProtocol(NTP)Server.FollowthisproceduretosettheNTPServerwithwhichtheAIPsynchronizesitsdateandtime.1 IntheSystemMenubar,clickSystem Configuration > Set NTP Server.2 IntheNTP Serverbox,entertheURLoftheNTPserverwithwhichyouwanttheAIPtosynchronize.3 IntheNTP synchronizing intervalmenu,selecthowmanyhoursshouldpassbetweensynchronization.4 ClickApply.

ASynchronization with NTP Server was successfulmessageshoulddisplay.IftheAIPcannotsynchronizewithanNTPServer,amessagedisplayspromptingyoutosetthetimemanually.Shouldthisoccur,followthestepsin"TroubleshootingNTPServerErrors”onpage 94.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 48 ©February 2017 CommScope, Inc.

Page 55: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Set the System Information

SET THE SYSTEM INFORMATION

FollowthestepsinthefollowingsubsectionstolabelandconfiguretheAIPanditsmodules.Set the System NameTheSystem NameidentifiesanAIPsystem.ItappearsatthetopoftheSystemTreehierarchy,withindividualMainandSecondaryAIPsbeneathit.

1 IntheSystemMenubar,clickSystem Configuration > Set System Name.2 IntheSystem Namebox,enterauniquenameforthisAIPsystem.

3 ClickApply.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 49

Page 56: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Set the System Information

Configure an AIP 1 IntheSystemTree,clickontheAIPthatyouwanttoconfigure.2 IntheSystemMenubar,clickSystem Information > Get Information.3 IntheAIP Namebox,enterauniquenameforthisAIP.TheAIP NameappearsatthetopoftheSystemTreehierarchy,withindividualMainandSecondaryAIPsbeneathit.ThedefaultnameisAIP_MAIN.4 IntheSite Number box,enteranumberthatwillallowyoutoidentifywheretheAIPislocated.TheMode SettingfieldindicatestheroleoftheAIPselectedinStep1.

• Main—theAIPwillactastheMainAIPinacascade.IftheAIPissetastheMainAIP,therewillbeaSwitch to Secondarybutton.AMainAIPobtainsanIPaddressthroughitsNetworkportfromtheNetworkDHCPserverforaccesstotheGUI.TheMainAIPthenautomaticallyassignsIPaddressestoSecondaryAIPsinthecascade.(TheMainAIPCraftportprovidesaDHCPserversoanyconnectedPCcanautomaticallyobtainadynamicIPaddress.)

• Secondary—theAIPwillactasaSecondaryAIPinacascade.ASecondaryAIPCraftportonlyhasastaticIPaddress.AnyPCconnectedtothisportmustthereforebeconfiguredwithastaticIPaddress.RecommendconfigurationforthePCis:

ToaccesstheEMS,enterthefollowingURLaddressintheIEWebAddressbox:https://192.168.0.1

5 IntheEquipment Number box,enteranumberthatwillallowyoutoidentifythisAIP.

6 (InitialSetupOnly)TochangeanAIPfromMaintoSecondary,clickSwitch to Secondary.CAUTION! The Mode Setting option should be set only during initial setup. Do not try to later change the Mode

Setting option. If you set the Main AIP as a Secondary AIP after initial system setup, access to that AIP and therefore to the AIP system will be lost.

7 ClickApply.

PCIPaddress: 192.168.0.25Netmask: 255.255.255.0Gateway: 192.168.0.1

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 50 ©February 2017 CommScope, Inc.

Page 57: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Set the System Information

Label an Individual Main or Secondary AIP TherearetwowaystolabelanAIP;youcanfolloweitherprocedure:• "LabelanAIPOption1”onpage 51• "LabelanAIPOption2”onpage 52.

Label an AIP Option 11 IntheSystemTree,clickontheAIPthatyouwanttolabel.2 IntheSystemMenubar,clickSystem Information > Set Labels.3 IntheUnit Label box,enterauniquenameforthisAIP.

4 ClickApply.TheAIPdisplaysintheSystemTreewithitsnewlabel.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 51

Page 58: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Set the System Information

Label an AIP Option 21 IntheSystemMenubar,clickSystem

Information > Set Labels.2 IntheSystemTree,clickontheAIPthatyouwanttolabel.3 IntheUnit Labelbox,enterauniquenameforthisAIP.4 ClickApply.TheAIPisrenamedwiththenewlabelintheSystemTree.

Label an ACU TherearetwowaystolabelanACU;youcanfolloweitherprocedure:• "LabelanACUOption1”onpage 52• "LabelanACUOption2”onpage 53.

Label an ACU Option 11 IntheSystemTree,clickontheACUthatyouwanttolabel.2 IntheSystemMenubar,clickSystem Information > Set Labels.3 IntheUnit Label box,enterauniquenameforthisACU.4 ClickApply.TheACUdisplaysintheSystemTreewithitsnewlabel.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 52 ©February 2017 CommScope, Inc.

Page 59: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Set the System Information

Label an ACU Option 21 IntheSystemMenubar,clickSystem Information > Set Labels.2 IntheSystemTree,clickontheACUthatyouwanttolabel.3 IntheUnit Labelbox,enterauniquenameforthisACU.

4 ClickApply.TheACUisrenamedwiththenewlabelintheSystemTree.Label a CSU TherearetwowaystolabelaCSU;youcanfolloweitherprocedure:

• "LabelaCSUOption1”onpage 54• "LabelaCSUOption2”onpage 54.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 53

Page 60: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Set the System Information

Label a CSU Option 11 IntheSystemTree,clickontheCSUthatyouwanttolabel.2 IntheSystemMenubar,clickSystem Information > Set Labels.3 IntheUnit Label box,enterauniquenameforthisCSU.4 ClickApply.TheCSUdisplaysintheSystemTreewithitsnewlabel.

Label a CSU Option 21 IntheSystemMenubar,clickSystem

Information > Set Labels.2 IntheSystemTree,clickontheCSUthatyouwanttolabel.3 IntheUnit Labelbox,enterauniquenameforthisCSU.4 ClickApply.TheCSUisrenamedwiththenewlabelintheSystemTree.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 54 ©February 2017 CommScope, Inc.

Page 61: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Set Up SNMP

SET UP SNMPTheSet Up SNMPpageallowsyoutomanageSNMP(SimpleNetworkManagementProtocol)events,suchasHeartbeat Interval andInform Resend,andmodifythedefaultSNMPPortnumber.TrapsandInformsareinthesamemessageformat,butanInformrequiresanacknowledgmentandaTrapdoesnot.IfanInformisnotacknowledgedwithinthetimespecifiedontheSet Up SNMPpage,itisresentforthespecifiedmaximumnumberofresends.(IfatrapreceiverisdefinedwithInformmessageprotocolontheSet SNMP Trappage,Trapscanalsoberesent;see"SetUpSNMPTrapManagers”onpage 56).NOTE: The Event Interval and Event Hysteresis parameters in the Set Up SNMP page have not been

implemented in this release and are not supported.DothefollowingtosettheSNMPmanagementparameters:1 IntheSystemMenubar,clickSystem Configuration > Set Up SNMP.

2 UsetheSNMP Port NumberboxtoentertheSNMPportnumberforsetsandgets(defaultis161).3 IntheSNMP Event Settingspanel,setthefollowingSNMPparameters:

a SetHeartbeat IntervaltoEnabledorDisabled,andthenifEnabled,inthecorrespondingsend every _ minute(s) (1-60)box,enterhowmanyminutes(1-60)shouldpassbetweenHeartbeatIntervals.

b SetInform ResendtoEnabledorDisabled,andthenifEnabled,inthecorrespondingsend every _ second(s) (1-600)box,enterhowmanyseconds(1-600)shouldpassbetweenInformResends,andthenintheMax Resends_ times (1-10)box,enterhowmanyresendattemptsshouldbemade(1-10).

c DonotsetEvent Hysteresis,asitisnotimplementedorsupportedinthisrelease.d DonotsetEvent Interval,asitisnotimplementedorsupportedinthisrelease.

4 ClickApply.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 55

Page 62: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Set Up SNMP Trap Managers

SET UP SNMP TRAP MANAGERS

TheSet SNMP TrappageallowsyoutoaddanddeleteSNMP(SimpleNetworkManagementProtocol)TrapManagers.1 IntheSystemMenubar,clickSystem Configuration > Set SNMP Trap.TheSet SNMP TraptablewillbeemptyuntiltheSNMPtrapsaresetup.

2 ClickNew.AlltheSNMP Agent Information settings,exceptfortheServer Address,areautofilledwithdefaultsettings.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 56 ©February 2017 CommScope, Inc.

Page 63: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Set Up SNMP Trap Managers

3 IntheSNMP Agent Informationpanel,setorchangethefollowingparameters:a IntheServer Addressbox,entertheIPaddressoftheSNMPserver;usethexxx.xxx.xxx.xxxformat.b IntheServer Portbox,entertheportnumberfortheSNMPserver.Thedefaultis162.c IntheTrap Communitybox,enterthepasswordthatwillallowaccesstothedevice(usuallypublicor

private).Thedefaultispublic.d UsetheTrap VersionradiobuttonstoselectthetrapversionfortheSNMPTrapManagerthatyouareregistering:

• V1• V2.

e UsetheTrap Alarm Typeradiobuttonstosetwhichtrapsaresent:• All—theEMSsendsalltraps.• Except BIU—theEMSsendsalltraps,exceptthosethatrelatetotheBIU.• Only selected—theEMSonlysendstrapsforthosemodulesselectedintheModuleListi SelectOnly selected.ii IntheModule List,selectthemodulesforwhichyouwanttohavetrapssent.ThefollowinggraphicshowsthattheServer AddressandtheTrap Alarm Typehasbeenchanged,butApplyhasnotyetbeenclicked.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 57

Page 64: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Set Up SNMP Trap Managers

4 ClickApply.TheSet SNMP TraptabledisplaysthenewSNMPTrap.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 58 ©February 2017 CommScope, Inc.

Page 65: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Deleting an SNMP Trap Manager

DELETING AN SNMP TRAP MANAGER

1 IntheSystemMenubar,clickSystem Configuration > Set SNMP Trap.TheSet SNMP TraptablelistsallactiveSNMPTrapManagers.2 IntheSet SNMP Traptable,clickontheSNMPTrapManagerthatyouwanttodelete.3 ClickDelete.

AconfirmationwindowopensthatidentifiestheSNMPTrapManagerthattheEMSwilldelete,intheformatofServer Address <xxx.xxx.xxx.xxx>,inwhich<xxx.xxx.xxx.xxx>istheIPaddressoftheSNMPTrapManager.4 Intheconfirmationwindow,verifytheServer Address,andthenclickYes.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 59

Page 66: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Deleting an SNMP Trap Manager

AnApply successfulmessageappearsandthedeletedSNMPTrapManagernolongerappearsintheSet SNMP Traptable.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 60 ©February 2017 CommScope, Inc.

Page 67: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Modifying an SNMP Trap Manager

MODIFYING AN SNMP TRAP MANAGER

AtanytimeyoucanchangethesettingsforanSNMPTrapManager.1 IntheSystemMenubar,clickSystem Configuration > Set SNMP Trap.TheSet SNMP TraptablelistsallactiveSNMPTrapManagers.2 IfthereismorethanoneSNMPTrapManager,intheSet SNMP Traptable,selecttheSNMPTrapManagerthatyouwanttomodify.3 Changethesettingsasapplicable.

4 ClickApply.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 61

Page 68: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Calibrate the CSU with the BIUs

CALIBRATE THE CSU WITH THE BIUS

ThefollowingstepscalibratetheCSUwiththeBIUs.ThecalibrationtoneisgeneratedbytheBIU,sowhenacalibrationisperformedtheBIUresidinginaspecificslotiscalibratedtothespecificCSUportconnectedtothatBIUslot.IfyoumoveaBIUtoadifferentslotafteracalibration,youneedtorecalibratetheBIUandCSU.CAUTION! CSU Calibration interrupts RF transmission for the selected BIU ports. CSU Calibration should only be run

during a normal maintenance window.DothefollowingtocalibratetheCSUwithBIUs.1 TerminatealldownlinkCSUQMAports.2 IntheSystemTree,selecttheBIUforwhichyouwanttocalibratetheCSU.3 IntheSystemMenubar,clickSystem Information > Get Information.IfaBIUisoutofcalibrationwiththeCSU,thedataintheDL CSU Insertion Loss dBcolumnwillbeinred.Inthefollowinggraphic,alloftheBIUsrequirecalibrationwiththeCSU.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 62 ©February 2017 CommScope, Inc.

Page 69: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Calibrate the CSU with the BIUs

4 ClickCalibrate CSU.AcheckboxforeachCSUcombinationopensintheCombinercolumn(seeexampleatright).NOTE: The Calibrate CSU button becomes the Cancel Calibrating CSU button. To

stop the CSU calibration, click Cancel Calibrating CSU.

5 SelectthecheckboxofintherowoftheBIUthatcorrespondstotheBIU(s)/CSU(s)thatareoutofcalibrationandthatyouwanttocalibrate.

6 ClickStart.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 63

Page 70: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Calibrate the CSU with the BIUs

7 IntheCalibration Cautionwindowthatopens,verifywhichBIU(s)willbecalibrated,andtheclickOK.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 64 ©February 2017 CommScope, Inc.

Page 71: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Calibrate the CSU with the BIUs

ACalibration progressdialogopenswithabarthatshowsyouthestatusofthecalibration.

8 Waituntilthecalibrationcompletes,andthenclickCloseintheCalibration progressdialog.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 65

Page 72: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Calibrate the CSU with the BIUs

ThecalibrateddownlinkinsertionlossfortheaffectedCSU/BIUcombination(s)isshownintheDL CSU Insertion Loss dBcolumninblackfont.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 66 ©February 2017 CommScope, Inc.

Page 73: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Managing BIUs

MANAGING BIUS

TheAIPEMSusesanhierarchicalSystemTreethatlistseachBIUundertheAIPinwhichtheBIUisinstalled.Getting BIU Information

NOTE: The information shown in the BIU Get Information page corresponds to the installed BIU configurations. This differs from the CSU Get Information page, which corresponds to the CSU serial number that identifies how the CSU was configured.

1 IntheSystemTree,selecttheBIUiconundertheAIPforwhichyouwanttoviewinformation.2 IntheSystemMenubar,click

System Information > Get Information.TheGet InformationpagethatisspecifictoBIUsopenswithatablethatlistsallinstalledBIUsinstalledinthesameAIPandprovidesthefollowinginformationforeachBIU.• RF Slot Number—identifiesinwhichAIPslottheBIUisinstalled.• Band—identifiestheBIUbandtype.• Name—user-assignednamefortheBIU.• DL IN Composite PWR dBm—theinputcompositepowerintotheAIPfromtheBaseStation(NodeBoreNodeB).• DL OUT Composite PWR dBm—thecompositepowerattheoutputoftheCSUandinputtotheDAS.• DL CSU Insertion Loss dB—measurementofdownlinkinsertionlossindBthroughtheCSU.• CombinerandSplitters—worktogethertodisplaytheCSU’scombinerandsplitterconfigurationandhowRFslotsmaptotheCSUUL/DLports.• Output Port—asnotedabove,theOutput PortcolumnrepresentstheCSUUL/DLpairstoshowthemappingofanRFslottoaCSUUL/DLportthroughtheCSUsplitter/combinerconfiguration(see"MappingtheCSUandBIUInstallationandConnections”onpage 7).• Editbutton—see"ChangingtheConfigurationofaBIU”onpage 70.• Deletebutton—see"DeletingaBIUfromtheAIPSystemSetup”onpage 85.• Storebutton—see"BackingupBIUConfigurations”onpage 77.• Restorebutton—see"RestoringaBackedUpBIUConfiguration”onpage 78.• Calibrate CSUandStartbuttons,see"CalibratetheCSUwiththeBIUs”onpage 62

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 67

Page 74: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Managing BIUs

Getting Information about BandsOnceyouaccesstheGet InformationpagespecifictoaBIU,youcanthengetinformationaboutaspecificband.1 IntheSystemTree,selecttheBIUiconundertheAIPforwhichyouwanttoviewinformation.TheGet InformationpagethatisspecifictoBIUsopenswithatablethatlistsallinstalledBIUsinstalledinthesameAIP,asshowninthefiguretotheright.2 Forthebandforwhichyouwanttoviewmoreinformation,clickontheradiobuttonintheRF Slot

Numbercolumnthatcorrespondstotheband.3 ClickEdit.Thepagetotherightdisplays.AtthetopofthepageisinformationabouttheBIUandband,asdescribedbelow.

• Model Number—typeofBIUinstalledinthisslot.• Serial Number—uniqueserialnumberassignedtothisBIU.• Software Version—versionofsoftwareinstalledonthisBIU.• Downlink Input Power—theinputcompositepowerintotheAIPfromtheBaseStation(NodeBoreNodeB).• Downlink Output Power—thecompositepowerattheoutputoftheCSUandinputtotheDAS.• Uplink Output Power—thetotalin-bandcompositepowerfromtheDASuplinkoutputport.• Temperature Value—thetemperatureoftheselectedBIU,showninCelsius(°C)degrees.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 68 ©February 2017 CommScope, Inc.

Page 75: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Managing BIUs

• Alarm—IfthereisanAlarmfieldatthebottomofthepage(seeexampletotheright),thereisanactivealarmontheBIU.ClickthealarmnametoopenanAlarm Detailswindowthatprovidesmoreinformationonthatalarm;forfurtherinformationgoto"ViewingBIUAlarmDetails”onpage 100.

Configuring BIUsTheBIUconfigurationparametersthatyoucansetareatthebottomoftheBIUGet Informationpage:

ThefollowingsectionsprovideyouwithanoverviewonhowtochangeaBIUparameteranddefinetheBIUparametersthatyoucanset.• "ChangingtheConfigurationofaBIU”onpage 70• "BIUConfigurationParameters”onpage 72.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 69

Page 76: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Managing BIUs

Changing the Configuration of a BIU

NOTE: If the Apply button is red, a parameter was changed but the change has not yet been applied. If you have collapsed the BIU menus on the Get Information page, expand them until you find a parameter name in red, which indicates which parameter change that clicking Apply will put into effect.ThebasicstepstoconfigureaBIUareasfollows:

1 IntheSystemTree,selecttheBIUiconundertheAIPforwhichyouwanttoconfiguretheBIUparameters.TheGet InformationpageopenswithatablethatlistsallinstalledBIUs.(ForinformationontheBIUtable,see"GettingBIUInformation”onpage 67.)2 ClickontheradiobuttonthatcorrespondstotheBIUthatyouwanttomanage,andthenclickEdit.

TheGet InformationpageexpandswithBIUparametersthatyoucannowedit.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 70 ©February 2017 CommScope, Inc.

Page 77: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Managing BIUs

3 Toeditaparameter,clickontheparametername,andthendoanyofthefollowing:• Ifamenuisshown,clickonthemenuname,andthenmaketheapplicableselectionviathelistedoptions.Inthefollowingillustration,theDownlink RF Settingparameterhasbeenclickedandthecorresponding

Downlink RF Enable/Disablemenuopened.

• Ifthereisacheckbox,selectordeselectthecheckboxtoenableordisablethesetting.TheillustrationtotheimmediaterightshowsthattheDownlink Allocated Over PoweralarmisbeingchangedfromEnabledtoDisabled.(Enabledisinredfont,andacheckmarkisnotdisplayed.)• Ifthereareoneormoretextfields,entertheappropriatesetting(s).TheillustrationtotheimmediaterightshowsthattheThresholdfortheUplink Over Poweralarmhasbeensetto

2.0 dBm.4 ClickApply.(IftheApplybuttonisblack,thennochangeshavebeenmadetoanyoftheBIUparameters.)Afterthecommandhasbeensuccessfullyexecuted,anApplysuccessfulmessagedisplays.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 71

Page 78: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Managing BIUs

BIU Configuration ParametersTheBIUconfigurationparametersaredefinedbelow.• Downlink RF Setting—allowsyoutoEnableorDisablethedownlinkRFfromthisBIU.

• Diagnostic Tone Setting

TheMHZsettingshowninparentheseswillbeapplicabletotheBIUandmaynotmatchwhatisshownintheprecedingillustration.IfDiagnostic ToneissettoEnable,adiagnostictoneisrunningonthisBIU.ForinformationonhowtousetheDiagnostic Tone Setting,see"UsingDiagnosticTones”onpage 75• Downlink AUTO Gain Setting

– Downlink Input Fully Loaded Composite Power _ dBm (25-50)allowsyoutosettheDownlinkInputAveragePower,whichmustbebetween25and50 dBm.Thedefaultsettingis30.– Downlink Output Fully Loaded Composite Power _ dBm (-25-15)allowsyoutosettheDownlinkOutputAveragePower,whichmustbebetween-25and15 dBm.Thedefaultsettingis15 dBm.– Output ALC level above Output Composite Power Level _ dB (1-5)allowsyoutosetthelevel1to5 dBabovetheusersetoutputlevelfortheDownlink Output Fully Loaded Composite Power.

Ifyouselectalevelof0 dBmout,theAIPwillsettheAIPgaintoachievethatoutput.YouthenmustsettheALCthresholdtothesettingofwhereyouwanttolimittheoutputpower. Ifyouselect1 dBabove,theAIPlimitsorauto-levelcontrols(ALC)theoutputto0+1=1dBmout.

– Downlink CSU Insertion Lossprovidesread-onlyinformationonwhatthecurrentDownlinkCSUInsertionLossisindB.– AIP Downlink Gainprovidesread-onlyinformationonwhatthecurrentAIPDownlinkGainisindB.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 72 ©February 2017 CommScope, Inc.

Page 79: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Managing BIUs

• Uplink Gain Setting

– Uplink CSU Insertion Loss—read-onlyinformationonwhatthecurrentUplinkCSUInsertionLossisindB.– Recommended Uplink DAS Gain—read-onlyinformationfortherecommendedUplinkDASGainindB.TypicallytheDASgainshouldbesetgreaterthanorequaltotheCSUlossforbestnoiseperformanceintheuplinkdirection.– BIU Uplink Gain _ dB (-31-0)—allowsyoutosetthegainoftheBIU.Thedefaultsettingis0,andwilltypicallyremain0foranoverall0dBsystemgain.

• High Temperature

– Threshold—read-onlyinformationonwhatthehigh-temperaturethresholdisfortheBIU,thatonceexceededwilltriggeranalarm.– Restore Threshold—read-onlyinformationonthetemperaturethatdetermineswhentoclearBIUHighTemperaturealarm(s).

• Downlink Major Over Power

Thismenuprovidesthefollowingread-onlyinformationonthresholdsfortheBIUDownlink Path Over Poweralarmsthatonceexceededgenerateamajoralarm:Alarm Threshold

Input Alarm Threshold 51.0 dBm

CAUTION! Power greater than +51 dBm can damage the AIP.Input Restore Threshold 50.0 dBm

Input Shutdown Threshold 53.0 dBm

Output Shutdown Threshold 25.0 dBm

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 73

Page 80: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Managing BIUs

• Downlink Allocated Over Power

– Enabledcheckbox—selecttoenabletheDownlink Path Over Poweralarm,deselecttodisablethealarm.– Threshold _ dBm (26-50)—usetosetthethreshold(indBm)fortheDownlink Path Over Poweralarm,whichonceexceededwillgeneratetheDownlink Path Over Poweralarm.– Restore Threshold _ dBm (<=n)—usetosetwhenDownlink Path Over Poweralarmsshouldclear,wherenisatleast1dBlowerthanthealarmthreshold.

• Uplink Over Power

– Enabledcheckbox—selecttoenabletheUplink Over Poweralarm,deselecttodisablethealarm.– Threshold _ dBm (>=-55)—usetosetthethreshold(indBm)fortheUplink Over Poweralarm,whichonceexceededwillgeneratetheUplink Over Poweralarm.– Restore Threshold _ (<=n)—usetosetwhenUplink Over Poweralarmsshouldclear,wherenisatleast1dBlowerthanthealarmthreshold.

• Downlink Under Power

– Enabledcheckbox—selecttoenabletheDownlink Path Under Poweralarm,deselecttodisablethealarm.– Threshold _ dBm (>=8)—usetosetthethreshold(indBm)fortheDownlink Path Under Poweralarm,whichonceexceededwillgeneratetheDownlink Path Under Poweralarm.– Restore Threshold _ dBm (>n)—usetosetwhenDownlink Path Under Poweralarmsshouldclear,wherenisatleast1dBhigherthanthealarmthreshold.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 74 ©February 2017 CommScope, Inc.

Page 81: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Managing BIUs

Using Diagnostic TonesUsetheDiagnostic Tone SettingtocommissionortroubleshoottheAIP.WhentheDiagnosticToneisEnabled,thediagnostictonewilloutputaCWsignalatalevelof0dBmreferencedtothedownlinkoutputoftheBIU;hence,thediagnostictone'slevelattheCSU'soutputwilldependontheCSUconfigurationused.Asanexample,ifaCSUwithatypicallossof4dBisused,thelevelattheCSUoutputwillbe0dBm-4dB=-4dBm.Thediagnostictoneisnon-adjustable,andanyAIPgainsettingsthatyouhaveconfiguredwillbeoverriddentoafixed0dBm.WhileEnabled,theDownlink AUTO Gain SettingwillbeDisabledandcannotbemodified.WhenthediagnostictoneisDisabled,theDownlink AUTO Gain Settingwillautomaticallyreverttotheleveltowhichyouhadconfiguredit.CAUTION! Running a diagnostic tone interrupts RF transmission for the BIU on which the diagnostic tone is being

run.Dothefollowingtorunadiagnostictone.1 IntheSystemTree,selecttheBIUiconundertheAIPforwhichyouwanttoconfiguretheBIUparameters.TheGet InformationpagethatisspecifictoBIUsopenswithatablethatlistsallinstalledBIUs.(ForinformationontheBIUtable,see"GettingBIUInformation”onpage 67.)2 ClickontheradiobuttonthatcorrespondstotheBIUforwhichyouwanttorunadiagnostictone,andthenclickEdit.

TheGet InformationpageexpandswithBIUparametersthatyoucannowedit.3 ClickDiagnostic Tone Setting.4 IntheDiagnostic Tone Frequencybox,enterthefrequencyforthediagnostictone.ThefrequencymustbewithinthefullbandsupportedbytheBIU;frequenciesthattheselectedBIUsupportsarelistedinparentheses.5 IntheDiagnostic Tonemenu,selectEnable.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 75

Page 82: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Managing BIUs

6 ClickApply.

7 IntheWarningdialog,clickOK.

AnApply Diagnostic Tone Frequencystatusbardisplays.

8 SelectDisableintheDiagnostic Tone Menutostopthediagnostictone.Ifyouskipthisstep,thediagnostictonecontinuestorunandtheRFsignaltothecorrespondingBIUwillfail.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 76 ©February 2017 CommScope, Inc.

Page 83: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Managing BIUs

Backing up BIU ConfigurationsYoucanbackuptheconfigurationofeachBIU,whichallowsyoutothenrestorethebackupconfigurationasnecessary,orapplythestoredconfigurationtoareplacementBIU.ThisprocedurebackstheBIUconfigurationupontheACU.1 IntheSystemTree,selecttheBIUiconundertheAIPforwhichyouwanttoconfiguretheBIUparameters.TheGet InformationpagethatisspecifictoBIUsopenswithatablethatlistsallinstalledBIUs.(ForinformationontheBIUtable,see"GettingBIUInformation”onpage 67.)2 ClickStore.TheStoredialogopens.3 IntheStoredialog,dothefollowing:

a DooneofthefollowingtoselectwhichBIUconfiguration(s)tobackup:• ClickthecheckboxintheheaderrowoftheStoretabletoselectalloftheBIUs.• ClickthecheckboxforeachBIUwhoseconfigurationyouwanttobackup.

b ClickStore.AprogressbardisplaystheprogressoftheStoreoperation,followedbyaStore successfulmessage.c ClickClose.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 77

Page 84: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Managing BIUs

Restoring a Backed Up BIU ConfigurationDothefollowingtorestoreabackedupconfigurationtoaBIUortoapplyabackedupconfigurationtoanewBIUthatisreplacinganolderBIUinthesameslot.1 IntheSystemTree,selecttheBIUiconundertheAIPforwhichyouwanttoconfiguretheBIUparameters.TheGet InformationpagethatisspecifictoBIUsopenswithatablethatlistsallinstalledBIUs.(ForinformationontheBIUtable,see"GettingBIUInformation”onpage 67.)2 ClickRestore.ARestoredialogopensthatlistsallBIUbackupfiles.Thebackupfilenamewillbeintheformatof:

<AIPName>_<BIU-Slot#>_<BIU Name>_YYYYMMDD_HHMMSS.ini(wheretheHHMMSSisin24-hourclockformat)Forexample:AIP_Main_BIU-S3_BIUAWS-1_S3_20140818_140712.ini

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 78 ©February 2017 CommScope, Inc.

Page 85: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Managing BIUs

3 Selecttherow(s)thatcorrespondtotheBIUconfiguration(s)thatyouwanttorestore.

4 ClickRestore.5 IntheConfirmwindow,verifythenameofthebackupfiletoberestored,andthenclickYes.

AprogressbardisplaystheprogressoftheRestoreoperation,followedbyaRestorefinishedmessage.6 IntheRestoredialog,clickClose.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 79

Page 86: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Managing BIUs

Exporting a BIU Configuration File to a PCDothefollowingtoexportaBIUbackupfiletoacomputer.1 Followthestepsin"BackingupBIUConfigurations”onpage 77tocreatebackupfilesoftheBIUconfigurationsettingsthatyouwanttobackuptoacomputer.2 IntheSystemTree,selecttheBIUiconundertheAIPforwhichyouwanttoexportbackedupBIUsettings.TheGet InformationpagethatisspecifictoBIUsopenswithatablethatlistsallinstalledBIUs.(ForinformationontheBIUtable,see"GettingBIUInformation”onpage 67.)3 ClickRestore.ARestoredialogopensthathasthefollowingcomponents:

• RF Slot Number—identifiesinwhichAIPslottheBIUisinstalled.• Name—user-assignednamefortheBIU.• RestoreFile—liststhenamesoftheBIUbackupfilesthathavebeenexported,intheformatof:

<AIPName>_<BIU-Slot#>_<BIU Name>_<Slot#>_YYYYMMDD_HHMMSS_<File#>.ini(wheretheHHMMSSisin24-hourclockformat)Forexample:AIP_Main_BIU-S2_BIU1900-1_S2_20140104_011445_006.ini

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 80 ©February 2017 CommScope, Inc.

Page 87: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Managing BIUs

4 ClickExport.AnExportconfirmationwindowopensthatliststhefilenameoftheBIUconfigurationbackupfile.

NotethatatthistimetheAIPhascompiledalloftheBIUbackupfilesintoasingletarfile.Thebackupfilenamewillbeintheformatof:<AIPName>_<BIU Name>_param_backup_YYYYMMDD_HHMMSS.tar.gz(wheretheHHMMSSisin24-hourclockformat)Forexample:AIP_Main_BIU-S_param_backup_20140104_011834.tar.gz

5 ClickExport.6 IntheSelect location for download by xxx.xxx.xxx.xxx(wherexxx.xxx.xxx.xxxistheAIPIPaddress)dialogthatopens,browsetothefolderinwhichyouwanttoexportthebackupfile.7 ClickSave.

8 Waitforthefiletoexporttothecomputer.9 IntheRestoredialog,clickClose.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 81

Page 88: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Managing BIUs

Importing and Restoring a BIU Backup File from a PCDothefollowingtoimportaBIUbackupfilefromacomputer.1 IntheSystemTree,selecttheBIUiconundertheAIPforwhichyouwanttoexportbackedupBIUsettings.TheGet InformationpagethatisspecifictoBIUsopenswithatablethatlistsallinstalledBIUs.(ForinformationontheBIUtable,see"GettingBIUInformation”onpage 67.)2 ClickRestore.ARestoredialogopensthatliststheBIUbackupconfigurationfiles.3 ClickImport.ASelect file to upload by xxx.xxx.xxx.xxx(wherexxx.xxx.xxx.xxxistheAIPIPaddress)opens.4 Browsetothefolderinwhichyouexportedthebackupfile.5 ClickontheBIUbackupfilethatyouwanttoimport.Thebackupfilenamewillbeintheformatof:

<AIPName>_<BIU Name>_param_backup_YYYYMMDD_HHMMSS.tar.gz(wheretheHHMMSSisin24-hourclockformat)Forexample:AIP_Main_BIU-S_param_backup_20140104_011834.tar.gz6 ClickOpen.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 82 ©February 2017 CommScope, Inc.

Page 89: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Managing BIUs

7 WaitforthefollowingmessagetodisplayintheRestoredialog:Import completed. Please click Restore8 IntheRestorewindow,clickRestore.9 IntheConfirmwindow,verifythenameofthebackupfiletoberestored,andthenclickYes.

AprogressbardisplaystheprogressoftheRestoreoperation,followedbyaRestore successfulmessage.

10 IntheRestoredialog,clickClose.Deleting a Backed Up BIU Configuration

1 IntheSystemTree,selecttheBIUiconundertheAIPforwhichyouwanttoexportbackedupBIUsettings.TheGet InformationpagethatisspecifictoBIUsopenswithatablethatlistsallinstalledBIUs.(ForinformationontheBIUtable,see"GettingBIUInformation”onpage 67.)2 ClickRestore.ARestoredialogopensthatliststheBIUbackupconfigurationfiles.3 ClickDelete File.4 IntheDelete Store Filewindowthatopens,clickDelete File.TheDelete Store FilewindowopenswithatablethatliststhebackupfileselectedinStep3.5 Dooneofthefollowing:

• ClickthecheckboxintheheaderrowoftheDeleteStoreFiletabletoselectallofthebackupfiles.• Clickthecheckboxforeachbackupfilethatyouwanttodelete.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 83

Page 90: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Managing BIUs

6 ClickDelete.

7 IntheInformationwindow,clickYes.

8 OncetheDelete successfulmessagedisplaysintheDelete Store Filewindow,clickClose.9 IntheRestorewindow,clickClose.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 84 ©February 2017 CommScope, Inc.

Page 91: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Managing BIUs

Deleting a BIU from the AIP System SetupTherearetwowaysthatyoucandeleteaBIUfromanAIPsystemasnotedin• "Option1:DeletingaBIUfromtheAIPSystemSetup”onpage 85• "Option2:DeletingaBIUfromtheAIPSystemSetup”onpage 86.

Option 1: Deleting a BIU from the AIP System Setup1 PhysicallyremovetheBIUfromtheAIPchassis.2 IntheSystemTree,selecttheBIUiconundertheAIPforwhichyouwanttoexportbackedupBIUsettings.TheGet InformationpagethatisspecifictoBIUsopenswithatablethatlistsallinstalledBIUs.(ForinformationontheBIUtable,see"GettingBIUInformation”onpage 67.)3 ClickontheradiobuttonthatcorrespondstotheBIUthatyouwanttodelete,andthenclickDelete.4 IntheConfirmdialog,whichidentifiestheBIUyouareabouttodelete,clickYes.

TheEMSremovestheBIUconfigurationfromtheBIUtableandfromtheEMS.NOTE: If the BIU is still in the AIP physically, after a few moments the BIU table will repopulate with its

information.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 85

Page 92: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Managing BIUs

Option 2: Deleting a BIU from the AIP System Setup1 PhysicallyremovetheBIUfromtheAIPchassis.2 IntheSystemTree,selecttheBIUiconundertheAIPforwhichyouwanttoexportbackedupBIUsettings.TheGet InformationpagethatisspecifictoBIUsopenswithatablethatlistsallinstalledBIUs.(ForinformationontheBIUtable,see"GettingBIUInformation”onpage 67.)4 ClickontheInformationiconthatcorrespondstotheBIUthatyouwanttodelete.AdialogopenswiththenameoftheselectedBIU:

5 ClickDelete Device.

6 IntheConfirmwindowthatopens,whichidentifiestheBIUyouareabouttodelete,clickYes.TheEMSremovestheBIUconfigurationfromtheBIUtableandfromtheEMS.NOTE: If the BIU is still in the AIP physically, after a few moments the BIU table will repopulate with its

information.

3 LookfortheInformationiconshowntotheright,whichindicatesthattheBIUhasbeenremovedfromthesystem.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 86 ©February 2017 CommScope, Inc.

Page 93: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Managing BIUs

Resetting AIP Components to Factory Default Settings

CAUTION! Resetting units to their factory default settings results in the following:

1 All BIU settings reset to their factory default settings.2 ACU Reset will reset the Mode Setting to Main.3 ACU Reset will reset Set Network Connection to Obtain an IP address automatically.DothefollowingtoresetanAIPcomponenttoitsfactorydefaultsettings.

1 IntheSystemTree,selecttheunitthatyouwanttoresettoitsfactorydefaultsettings.2 IntheSystemMenubar,clickSystem Configuration > Reset to Factory Default.

• IfinStep1youselectedAll AIPs,allunitsinthesystemwillbelistedintheReset to Factory Defaultpage.• IfinStep1youselectedanAIP,allunitsinthatAIPwillbelistedintheReset to Factory Defaultpage.• IfinStep1youselectedanACU,BIU,orCSU,allunitsinthecorrespondingAIPwillbelistedintheReset

to Factory Defaultpage.Allunitsthatcanberesettofactorydefaultwillbepreselected.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 87

Page 94: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Managing BIUs

3 UsethecheckboxesnexttotheAIPorunitnametoselectwhichAIP(s)orunit(s)youwanttoresettofactorydefault.Ifacheckmarkisnotinacheckbox,thatunitwillnotberestoredtofactorydefault.4 ClickReset.

5 IntheInformationwindow,clickYes.

ThecontentoftheReset to Factory Defaultpagechangestoshowtheprogressoftheunitreset.Oncetheunitresetiscomplete,anInformationwindowopenswithaReset to factory default was successfulmessage.6 IntheInformationwindow,clickOK.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 88 ©February 2017 CommScope, Inc.

Page 95: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Getting System Information

GETTING SYSTEM INFORMATION

YouusetheGet InformationcommandintheSystem Informationmenutogetinformationaboutthesystem,unit,ormoduleselectedintheSystemTree.Get System Information for All AIPs

1 IntheSystemTree,selectAll AIPs.2 Ifnecessary,intheSystemMenubar,clickSystem Information > Get Information.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 89

Page 96: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Getting System Information

TheGet InformationpagedisplaysthefollowinginformationforallAIPsconnectedtotheIPaddressaccessedduringlogin.• ID—auniquenumericalIDassignedtotheAIPthatindicatestheorderoftheAIPinacascade,wheretheMainAIPisalways1,thefirstcascadedAIPis2,thesecondcascadedAIPis3,andsoforth.• Label—auniquenameassignedtotheAIPbytheSystemAdministrator;see"LabelanIndividualMainorSecondaryAIP”onpage 51.• Site Number—auniquenumberassignedtothesitebytheSystemAdministratorthatidentifiesthesiteinwhichthisAIPisinstalled;see"ConfigureanAIP”onpage 50.• Equipment Number—auniquenumberassignedtothisAIPbytheSystemAdministrator;see"ConfigureanAIP”onpage 50.• Mode Setting—identifiesiftheroleoftheAIPwithinthesystemismanuallyorautomaticallyset:

– Main—theAIPwasmanuallysettoactastheMainAIPinacascade– Secondary—theAIPwasmanuallysettoactasaSecondaryAIPinacascade.

• Mode—whethertheAIPisactingasaMainorSecondaryAIP.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 90 ©February 2017 CommScope, Inc.

Page 97: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Getting System Information

Get ACU Information 1 IntheSystemTree,selecttheACUforwhichyouwanttoviewinformation.2 Ifnecessary,intheSystemMenubar,clickSystem Information > Get Information.

TheEMSprovidesthefollowinginformationandoptionsfortheACUselectedintheSystemTree.• Model Number—numberassignedbyCommScopetoidentifythisACUmodeltype.• Serial Number—uniqueidentifyingnumberassignedtothisACUduringmanufacturing.• Software Version—versionofsoftwareinstalledontheACU.• Kernel Version—versionoftheLinuxsoftwareinstalledontheACU.• Self Mapping Testfield—providesinformationinwhetherandwhenaSelfMappingTestwasrun.• Setting Equipment Current Timecalendar—onlyusethisfeatureifthereisanNTPServererror;see"TroubleshootingNTPServerErrors”onpage 94.• ACU Rebootbutton—clicktoreboottheACU;see"RebootinganACU”onpage 93.• Self Mapping Testbutton—clicktoexecuteaSelfMappingTest,whichidentifieshowtheBIUsmaptotheCSU;see"RunningaSelfMappingTestonaCSU”onpage 96.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 91

Page 98: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Getting System Information

Get CSU Information

NOTE: The information shown in the CSU Get Information page corresponds to the CSU serial number, which identifies how the CSU was configured. This differs from the BIU Get Information page, which shows how the installed BIUs are configured.DothefollowingtoobtaininformationabouttheCSU:

1 IntheSystemTree,selecttheCSUforwhichyouwanttoviewinformation.2 Ifnecessary,intheSystemMenubar,clickSystem Information > Get Information

TheEMSprovidesthefollowinginformationforthesplitterandcombinerconfigurationfortheCSUselectedintheSystemTree,whichshowsinputfromtheBIUstotheconnectedUL/DLoutputportsontheCSU.• Model Number—numberassignedbyCommScopetoidentifythisCSUmodeltype.• Serial Number—uniquenumberassignedtothisCSUduringmanufacturing.• Software Version—versionofsoftwareinstalledontheCSU.• Downlink Output Power 1-Downlink Output Power 8—thecompositepowerofeachCSUDLport.• CSU Voltage Value—thenumberofvoltsthattheCSUisusing.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 92 ©February 2017 CommScope, Inc.

Page 99: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Rebooting an ACU

REBOOTING AN ACU1 IntheSystemTree,selecttheACUthatyouwanttoreboot.2 Ifnecessary,intheSystemMenubar,clickSystem Information > Get Information.3 ClickACU Reboot.AprogressbaropenstoadviseyouoftheACUrebootstatus.

4 DonotattemptanyotherconfigurationchangesuntilaftertheReboot successfulmessagedisplays.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 93

Page 100: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Troubleshooting NTP Server Errors

TROUBLESHOOTING NTP SERVER ERRORS

TheAIPautomaticallyattemptstoconnecttotheNTPserverspecifiedintheSet NTP Serverpage.IftheAIPcannotaccesstheserver,theEMSpromptsyoutosetthetimemanually,asshownbelow.

TheenvelopeintheprecedinggraphicistheMessageListicon,whichindicatesthatyouhaveasystemmessageavailable.ThenumbernexttotheMessageListicontellsyouhowmanysystemmessagesthereareinthelist.ClickontheMessageListicontoviewthesystemmessage(s),asshownbelow.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 94 ©February 2017 CommScope, Inc.

Page 101: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Troubleshooting NTP Server Errors

DothefollowingtosettheAIPtimeanddatemanually.1 IntheSystemTree,selecttheACUinstalledintheMainAIP.2 Ifnecessary,intheSystemMenubar,clickSystem Information > Get Information.3 ClicktheSetting Equipment Current Timecalendar.TheAIPwillsynchronizewiththetimeanddateofthePCtowhichitisconnected.

4 ClickApply.5 RepeatthisprocedureforeachAIPinacascadedsystem.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 95

Page 102: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Running a Self Mapping Test on a CSU

RUNNING A SELF MAPPING TEST ON A CSUIfyouselectanAIPintheSystemTreeandthenclickSystem Information > Get Information,therewillbeaSelf Mapping TestbuttonontheGet Informationpagethatopens.Thisfeatureisnolongersupportedandshouldnotbeused.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 96 ©February 2017 CommScope, Inc.

Page 103: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Viewing Alarms

VIEWING ALARMS

ThefollowingsectionsdefinehowtheAIPEMSindicatesalarmsandhowtoaccessalarminformation.Alarm IndicatorsTheEMSusescolorcodestoindicatethelevelofthealarmorevent,asdescribedinTable4-3andshowninFigure 4-4.

Figure 4-4. Understanding Alarm Indicators

Table 4-3. Alarm Indications in the EMS GUI

Alarm Type* Color Code Comments

No alarm Green There is no active major or minor alarm.

Minor* Orange A minor alarm is active.

Major Red A major alarm is active.

*If more than one alarm is active for a module or system, the indicator for the highest level alarm is shown.

1

2

1 An alarm indicator next to a module shows which module is in an alarm state, and the severity of the alarm.2 The highest level of alarm severity in the AIP is shown in by an alarm indicator next to the System Name.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 97

Page 104: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Viewing Alarms

Viewing Alarm Details on an ACU or CSU Get Information PageIntheGet InformationpageforACUsandCSUs,ifthemodulehasanactivealarm,theEMSliststhealarmatthebottomofthepage,withanalarmindicatorshowingthealarmseveritylevel,asshowninFigure 4-5.NOTE: The examples in this section show alarms for an ACU. You follow the same steps to access alarm details

for a CSU.

Figure 4-5. ACU Alarm Example

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 98 ©February 2017 CommScope, Inc.

Page 105: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Viewing Alarms

Dothefollowingtoopenanexpandedalarmview.1 Clickonthealarmname.

Anewdialogopenswithfurtherinformationonthealarm.

2 ClickClosetoclosetheexpandedalarmview.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 99
Page 106: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Viewing Alarms

Viewing BIU Alarm DetailsIntheGet InformationpageforBIUs,iftheBIUhasanactivealarm,analarmindicatorwillbenexttotheRF Slot Number,asshowninFigure 4-6,inwhichtheBIUinstalledinSlot6hasanactiveminoralarm.

Figure 4-6. BIU Alarm IndicatorDothefollowingtoviewfurtherinformationonaBIUalarm:1 SelecttheradiobuttonnexttotheRF Slot Numberforwhichyouwanttoviewthealarmdetails.2 ClickEdit.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 100 ©February 2017 CommScope, Inc.

Page 107: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Viewing Alarms

3 AftertheGet Informationpageexpands,listingtheactivealarm(s),clickonthealarmname.

AnAlarm Detailswindowopenswithfurtherinformationonthealarm,includingaRemedythattellshowtoresolvethealarm.

4 ClickClosetoclosetheexpandedalarmview.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 101

Page 108: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Viewing Alarms

View Current AlarmsToviewalarmsthatarecurrentlyactive,dooneofthefollowing:• ToviewalarmsfromthewholesystemincludinganycascadedAIPs,intheSystemMenubar,clickAlarms >

View Current Alarms,andthenintheSystemTreeselecttheAll AIPsicon.• ToviewalarmsforaspecificAIP,intheSystemMenubar,clickAlarms > View Current Alarms,andthenintheSystemTreeselecttheiconoftheAIPwhosecurrentalarmsyouwanttoview.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 102 ©February 2017 CommScope, Inc.

Page 109: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Viewing Alarms

TheView Current Alarmstableprovidesthefollowinginformation:• Severity—whetheralarmisclassifiedasMajororMinor.Notethatminoralarmswillhaveanorangecolorcode,andminoralarmswillhavearedcolorcode.• Alarm Name—descriptivenameofalarm.• Timestamp—dateandtimewhenthealarmoccurred(YYYY:MM:DD:HH:MM:SS).• Unit ID—identifiestheunitwithinthesystembyitsuse-assignedlabel.• Module—typeofmodulewithinthespecifiedunitthatisexperiencingthealarm(ACU,BIU,CSU).• Extended Info—clickontheview detailslinktoopenanAlarmDetailswindowthatprovidesextensiveinformationaboutthealarmthatincludesaremedyforthealarmedissue.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 103

Page 110: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Viewing Alarms

View an Alarm HistoryTheView Historytabledoesnotlistactivealarms.OnlythosealarmsthathavebeenclearedandarenolongeractiveappearintheView Historytable.Toviewthehistoryofclearedalarms,intheSystemMenubar,clickAlarms > View History.

TheView Historytableprovidesthefollowinginformation:• ID—auniquenumericalidentifierassignedtothealarmbytheEMS.• Severity—whetheralarmisclassifiedasMajororMinor.• Alarm Name—descriptivenameofalarm.• Timestamp—dateandtimewhenthealarmoccurred(YYYY:MM:DD:HH:MM:SS).• Unit ID—identifiestheunitwithinthesystembyitsuse-assignedlabel.• Module—typeofmodulewithinthespecifiedunitthatisexperiencingthealarm(ACU,BIU,CSU).• Clear Timestamp—dateandtimethatthealarmwascleared,ifever.ForfurtherinformationonhowtousetheView Historytable,seethefollowingsectionsofthisguide:• "FilteringtheViewHistoryTable”onpage 105• "ExportinganAlarmHistory”onpage 107.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 104 ©February 2017 CommScope, Inc.

Page 111: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Viewing Alarms

Filtering the View History Table(Optional)Dothefollowingtofilterthetimeframeforwhichyouwanttoviewanalarmhistoryand/ortofilterthenumberofalarmslisted.1 IntheSystemMenubar,clickAlarms > View History.2 ClickFiltertoopentheFilterdialog:

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 105

Page 112: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Viewing Alarms

3 Doanyofthefollowing:• Tofilterthetimerangeofdisplayedalarms,undertheTime rangeheadingselectoneofthefollowing:

Unlimited Past day Past 3 days Past week Past month Custom—IfyouselectCustom,Start dateandEnd datetextboxeswithCalendariconsdisplayinthe

Filterwindow.ClickontheCalendariconstoselectthedaterangeforwhichyouwanttofilterthealarmhistory.

• Tofilterthehowmanyalarmrecordsarelisted,undertheRecord rangeheadingselectoneofthefollowing: Unlimited The most recent 50 The most recent 100 The most recent 200 The most recent 500

4 ClickOK.TheView Historytablepopulateswithahistoryofallalarmsthatoccurredduringthespecifiedrange.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 106 ©February 2017 CommScope, Inc.

Page 113: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Viewing Alarms

Exporting an Alarm HistoryYoucanexporttheAlarmHistorytoacomputerincommaseparatedvalues(csv)formatthatcanbereadbyMicrosoftExcelorothertoolsthatcandisplayatextfile.1 Followthestepsin"ViewanAlarmHistory”onpage 104.2 ClickExport All.3 IntheAlarm Export dialog,clickExport.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 107

Page 114: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Viewing Alarms

4 IntheSelect locationdialog,browsetowhereyouwanttodownloadthereport,andthenclickSave.(ThisstepshowsdownloadingthefilethroughInternetExplorer.Ifyouareusingadifferentbrowser,followthatbrowser’spromptstodownloadthefile.)

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 108 ©February 2017 CommScope, Inc.

Page 115: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Viewing Alarms

5 Waitforthedownloadtocomplete,atwhichtimetheAlarm Export dialogclosesautomatically.ThefileissavedinCSVformat.Thefilenameisintheformatof:Almyyyymmdd_hhmmss.csv(<alarmname><year><month><date>_<hour><minutes><seconds>.csv).

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 109

Page 116: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Viewing Alarms

Clearing the Alarm History1 IntheSystemMenubar,clickAlarms > View History.2 ClickClear All.

ThecontentsoftheView Historytableisclearedandthealarmhistoryforthesystemisdeleted.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 110 ©February 2017 CommScope, Inc.

Page 117: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Clearing Disconnect Alarms

CLEARING DISCONNECT ALARMS

DothefollowingtoclearalarmsformodulesthathavebeendisconnectedorremovedfromtheAIP.1 IntheSystemMenubar,clickAlarms > View Current Alarms.2 ClickClear Disconnected Alarm.

TheEMSclearsthealarmfromtheView Current Alarms table,andamessagethatthealarmhasbeenclearedappearsatthetopofthepage.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 111

Page 118: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Upgrading an AIP System

UPGRADING AN AIP SYSTEM

ForinformationonhowtoupdatetheAIPoranyofitscomponents,refertotheAIPsoftwarereleasenotesthatcorrespondtotheAIPsoftwarereleaserunningonthissystem.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 112 ©February 2017 CommScope, Inc.

Page 119: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Using a Static IP Address for the Main AIP Craft Port

USING A STATIC IP ADDRESS FOR THE MAIN AIP CRAFT PORT

Therearetwomethods(IPAddressing)thatcanbeusedtoaccesstheCraftportontheMainAIP.• IfyouconfigureyourPCforDynamicHostConfigurationProtocol(DHCP),thenyouaccesstheAIPCraftportatthefollowingIPaddress:

https://192.168.2.1 • ToconfigureyourPCforstaticIPaddressing,usethefollowingsettings:

YouthenaccesstheAIPCraftportatthefollowingIPaddress:https://192.168.0.1 TheadvantageinusingstaticIPaddressingisthatwhenmovingbetweentheMainAIPCraftportandtheSecondaryAIPCraftport,thePCandwebbrowserEMSIPaddressingremainsthesameforbothports.Thatis,theEMSontheMainandSecondaryCraftportsisaccessedat:https://192.168.0.1

ThefollowingstepstellyouhowyoucansettheMainAIPwiththestaticIPaddressof:https://192.168.0.1.Pleasenotethatifyoufollowthesesteps,yourPCwillnotbesetupforDHCP.YoushouldonlymakethefollowingchangesifyoudonotcareifyourPCissetforDHCP.DothefollowingtochangetoastaticIPaddress.1 ConfigureyourPCforstaticnetworking,withthefollowingsettings:

2 Logintoyourcomputerandstartawebbrowser.3 IntheIEWebAddressbox,enterthefollowingURL:

https://192.168.0.1 4 ClickTools > Internet Options.TheInternet Options dialogopens.

IP address 192.168.0.25

Subnet mask 255.255.255.0

Gateway 192.168.0.1

PCIPaddress: 192.168.0.25Netmask: 255.255.255.0Gateway: 192.168.0.1

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 113

Page 120: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Using a Static IP Address for the Main AIP Craft Port

5 ClicktheSecuritytab,selectTrusted sites,andthenclickSites,asshowninthegraphictotheright.

TheTrusted sitesdialogopens.

6 UnderAdd this website to the zone,addthenewstaticIPaddressfortheAIPsystem(https://192.168.0.1),andthenclickAdd.7 ClickClose.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 114 ©February 2017 CommScope, Inc.

Page 121: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Using a Static IP Address for the Main AIP Craft Port

8 IntheInternet Optionsdialog,clickOK.

Now,wheneveryoulogontotheAIPsystem,intheIEWebAddressbox,enterthefollowingURL:https://192.168.0.1

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 115

Page 122: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Managing Users

MANAGING USERS

TheEMSprovidessecurity,whichcanbebroadlyclassifiedas:• UserAuthentication—definesthewayauserisidentifiedpriortobeingallowedtologontotheEMS.UserAuthenticationensuresthatonlyknownusershaveaccessbyprovidingamethodofidentifyingeachuserthroughauserIDandpassword.• UserAuthorization—managestheuser’sprivilegesintheAIPnetworkmanagementinfrastructurebyrestrictingsystemaccessaccordingtopredefinedusergroupprivileges.Table4-4liststhedefaultAIPEMSuseraccounts.

TheAIPEMSusestheUser Groupparametertosettheuser’sprivilegeswithintheAIPsystem:• admin—theadminuser,whocanviewandconfigureallAIPsettings.• guest—theguestuserdoesnothaveapassword.TheguestusercanonlyviewtheAIPsysteminformationandalarms,andcannotchangeanyofthesettings.

Viewing UsersIntheSystemMenubar,clickSecurity > Manage Users.

TheManage Userstableprovidesthefollowinginformation:• Login Name—theuniquenameassignedtothisuserthatidentifiestheusertotheGUIforsecurityandloginpurposes.• User Name—thenameoftheuser,whichisoftentheuser’srealnameorfunction,andmaybedifferentfromtheLogin Name.• User Group—identifiestheuser’sprivilegeswithintheAIPsystem.

Table 4-4. Default User Accounts

User Name Default Password User Group

admin admin admin

guest guest viewer

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 116 ©February 2017 CommScope, Inc.

Page 123: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Managing Users

Add a New User1 IntheSystemMenubar,clickSecurity > Manage Users.2 IntheManage Userspage,clickNew.

TheManage Userspageexpandswiththeparametersnecessarytocreateanewuser:

3 IntheLogin Namebox,enteranamethattheuserwillusetologintotheAIPEMS.4 IntheUser Namebox,entertheuser’srealnameorotheridentifyinginformation.5 IntheUser Groupmenu,selecttheaccesslevelforthisuser:adminorviewer.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 117

Page 124: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Managing Users

6 ClickApply.TheEMSaddsthenewusertotheManage Userstable.

7 (Optional)Toassignapasswordtotheuser,followthestepsin"ChangethePasswordofanotherUser”onpage 120.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 118 ©February 2017 CommScope, Inc.

Page 125: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Managing Users

Delete a User1 IntheSystemMenubar,clickSecurity > Manage Users.2 IntheManage Userstable,selecttherowthatcorrespondstotheuserthatyouwanttodelete.3 ClickDelete.

AConfirmdialogopensthatidentifiestheuserthatyouwilldeletebyhisorherUser Name.4 IntheConfirmdialog,clickYes.

TheEMSremovestheuserfromthesystemandfromtheManage Userstable.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 119

Page 126: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Managing Users

Change the Password of another User1 IntheSystemMenubar,clickSecurity > Manage Users.2 IntheManage Userstable,selecttherowthatcorrespondstotheuserwhosepasswordyouwanttochange.3 ClickChange Password.

4 DothefollowingintheChange Passworddialog:a IntheNew Passwordbox,enteranewpasswordfortheselecteduser.b IntheConfirm Passwordbox,retypethesamepasswordthatyouenteredintheNew Passwordbox.c ClickOK.

d Waitforthe Password change successfulmessage,andthenclickDone.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 120 ©February 2017 CommScope, Inc.
Page 127: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Managing Users

Changing Your Own Password1 IntheSystemMenubar,clickSecurity > Change Password.TheChange Passworddialogopens.

2 IntheOld Passwordbox,typeyourcurrentpassword.3 IntheNew Passwordbox,typeanewpassword.4 IntheConfirm Passwordbox,typeyournewpasswordexactlyasyouentereditinStep 3.

5 ClickOK.6 WaitforPassword change successfulmessage,andthenclickDone.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 121

Page 128: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Viewing the AIP EMS Release Information

VIEWING THE AIP EMS RELEASE INFORMATION

1 ToviewreleaseinformationfortheAIPEMS,intheSystemMenubar,clickHelp > About.

TheAboutdialogprovidesthefollowinginformation:• Version—versionnumberoftheEMS.• Date—datethatthisEMSsoftwarewasreleased.

2 ClickOKtoclosetheAboutdialog.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 122 ©February 2017 CommScope, Inc.

Page 129: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Logging Out of the AIP

LOGGING OUT OF THE AIPDothefollowingtologoutoftheAIPEMS:1 FromanyGUIpage,clicktheLogoutlink.

2 IntheConfirmationdialog,clickYes.

3 Closeyourwebbrowser;thisensuresatotaldisconnectfromtheAIPEMS.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 123

Page 130: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Alarm Reference

ALARM REFERENCE

ThissectionliststhealarmsthattheAIPEMScangenerate.Thealarmsarelistedinalphabeticalorderbyalarmname.ToassistyouintroubleshootinganAIPsystem,aremedyforeachalarmisalsoprovided.Alarm: ACU/Other Module Link Alarm

Affected Module: BIU/CSUCause/Impact: ThecommunicationbetweentheACUandtheBIUorCSUfailed.Remedy: Dothefollowingintheorderpresented:MakesuretheBIU/CSUispresentandseatedfirmlyintheirrespectiveslots.VerifypowertotheAIPisconnectedandpoweredon.Ifalarmpersists,contactCommScopetoreplacetheBIUorCSU.Severity: MinorAlarm: Communication Link Alarm

Affected Module: BIUCause/Impact: BIUisnotcommunicatingwiththeACU.Remedy: MakesuretheBIUispresentandseatedfirmlyinitsslot.Ifalarmpersists,contactCommScopetoreplacetheBIU.Severity: MajorAlarm: Communication Link Alarm

Affected Module: CSUCause/Impact: ThecommunicationbetweentheACUandtheCSUfailed.Remedy: Dothefollowingintheorderpresented:MakesuretheCSUisseatedfirmlyinitsslot.VerifypowertotheAIPisconnectedandpoweredon.Ifalarmpersists,contactCommScopetoreplacetheCSU.Severity: MajorAlarm: Communication Link Alarm

Affected Module: ACUCause/Impact: CAT5cableisdisconnected.Remedy: MakesuretheACUCAT5cableispresentandseatedfirmlyinthecorrectRJ45port.Ifalarmpersists,replacetheCAT5cable.Severity: Major

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 124 ©February 2017 CommScope, Inc.

Page 131: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Alarm Reference

Alarm: Disconnect Alarm

Affected Module: BIUCause/Impact: TheBIUisnotseatedfirmlyinitsslotorhasbeenremoved.Remedy: MakesuretheBIUispresentandseatedfirmlyinitsslot.Ifalarmpersists,contactCommScopetoreplacetheBIU.Severity: MinorAlarm: Disconnect Alarm

Affected Module: CSUCause/Impact: CSUisnotcommunicatingwiththeACU.Remedy: Dothefollowingintheorderpresented:MakesuretheCSUispresentandseatedfirmlyinitsslot.VerifypowertotheAIPisconnectedandpoweredon.Ifalarmpersists,contactCommScopetoreplacetheCSU.Severity: MinorAlarm: Downlink Allocated Over Power Alarm

Affected Module: BIUCause/Impact: DownlinkInputPowerhasexceededitsThresholdvalue.Remedy: ReducetheDownlinkInputPowerorraisetheThresholdvalue(BIU > System Information

> Get Information).Severity: MinorAlarm: Downlink Major Over Power Alarm

Affected Module: BIUCause/Impact: DownlinkInputPowerisover51dBm.Remedy: ReduceDownlinkInputPowerbelow50dBm(BIU > System Information > Get Information).Severity: MajorAlarm: Downlink Under Power Alarm

Affected Module: BIUCause/Impact: NodownlinkRFinputorverylowinputpower.Remedy: Dothefollowingintheorderpresented:CheckthefeedercablebetweentheBIUandtheBTS,reseatconnectorsifnecessary,orreplacebrokencable.IncreasethedownlinkinputpowertothedesiredrangeorincreasetheDownlink Under Powerthreshold(BIU > System

Information > Get Information).Severity: Minor

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 125

Page 132: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Alarm Reference

Alarm: Fan Alarm

Affected Module: FanModuleCause/Impact: OneoutoffourFanModulesintheAIPhasfailed.Remedy: ReplacewithnewFanModule.Severity: MinorAlarm: Fan Alarm

Affected Module: FanModuleCause/Impact: TwoormoreFanModulesintheAIPhavefailed.Remedy: ReplacewithnewFanModules.Severity: MajorAlarm: High Temperature Alarm

Affected Module: BIUCause/Impact: Canbeanyofthefollowingcauses(inwhichyouwillmatchtheCauseNumbertotheRemedyNumber):

1 TheDownlinkInputAveragePowerissettoohigh,whichcausedtheBIUtooverheat.2 AIPFanModulefailurecausedtheBIUtooverheat.3 BIUtemperaturesensorfailed.

Remedy: MatchtheRemedyNumbertotheCauseNumber:1 ReducetheDownlinkInputFullyLoadedCompositePowertobetween25and50dBm(BIU > System Information > Get Information).2 VerifythattheAIPintakeandexhaustventsareclearofobstructionsand/ordebris.Ifalarmpersists,replacethefailedFanModule.3 ContactCommScopetoreplacetheBIU.

Severity: MinorAlarm: Uplink Over Power Alarm

Affected Module: BIUCause/Impact: UplinkOutputPowerhasexceededitsThresholdvalue.Remedy: ReducetheUplinkGainSettingorincreasetheDownlinkAllocatedOverPowervalue(BIU

> System Information > Get Information).Severity: Minor

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 126 ©February 2017 CommScope, Inc.

Page 133: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Chapter Topics Page

Install the AIPs........................................................................................................................................................................................................126Verify the AIP EMS Release on each AIP ................................................................................................................................................................127Establish the Main AIP............................................................................................................................................................................................128Designate Cascaded AIPs as Secondary Units in the AIP EMS................................................................................................................................129Physically Cascade the AIPs....................................................................................................................................................................................131Managing Cascaded AIPs........................................................................................................................................................................................132Troubleshooting Secondary Units ..........................................................................................................................................................................133

TheinformationinthischaptertellsyouhowtocascadeAIPstogetherandhowtousetheAIPEMStoconfigurethecascadedsystem.Youwillfindthefollowingfontconventionsinusethroughoutthischapter.• This fontrepresentsareferencetoanEMSdialogbox,menuitem,configurationoption,orotherparameter.• This fontrepresentsnon-variabletextthatyoutypeataprompt.• THIS FONTrepresentskeysthatyouneedtopressonyourkeyboard.

WORKING WITH CASCADED AIPS5

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 127

Page 134: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Install the AIPs

INSTALL THE AIPS

Followthestepsin"InstallingtheAIP”onpage 11toinstalltheAIPs.CAUTION! Do not physically connect the Secondary AIPs to the Main AIP until directed to do so.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 128 ©February 2017 CommScope, Inc.

Page 135: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Verify the AIP EMS Release on each AIP

VERIFY THE AIP EMS RELEASE ON EACH AIPAllAIPsinthecascademustbeatthesameAIPEMSreleaselevel.Iftheyarenotatthesamerelease,theAIPswillnotbeabletocommunicatewithinthecascade.DothefollowingoneachAIPthatistobeaddedtothecascade:1 OpentheAIPEMSinanInternetExplorerbrowser(IEVersion8orlater).2 ToviewreleaseinformationfortheAIPEMS,intheSystemMenubar,clickHelp > About.3 Writedownthefollowinginformation:

• Version—versionnumberoftheEMS.• Date—datethatthisEMSsoftwarewasreleased.

4 ClickOKtoclosetheAboutdialog.5 IntheSystemTree,selecttheACUforwhichyouwanttoviewinformation.6 Ifnecessary,intheSystemMenubar,clickSystem Information > Get Information.7 WritedowntheSoftware VersionofthesoftwareinstalledontheACUandtheKernel VersionoftheLinuxsoftwareinstalledontheACU.8 IntheSystemTree,selecttheCSUforwhichyouwanttoviewinformation.9 Ifnecessary,intheSystemMenubar,clickSystem Information > Get Information

10 WritedowntheSoftware VersionofthesoftwareinstalledontheCSU.11 IntheSystemTree,selecttheBIUiconundertheAIPforwhichyouwanttoviewinformation.12 IntheSystemMenubar,clickSystem Information > Get Information.13 Forthebandforwhichyouwanttoviewmoreinformation,clickontheradiobuttonintheRF Slot Numbercolumnthatcorrespondstotheband.14 ClickEdit.15 WritedowntheSoftware VersionofthesoftwareinstalledontheBIU.16 ForeachBIUinstalledintheAIP,repeatStep 11throughStep 15.17 RepeatthisprocessforeachAIPthatistobeaddedtothecascade.18 Ifthesoftwareversionsofanyofthecomponents(AIPEMS,ACU,BIU(s),orCSU)isnotatthelatest(highest)softwarerelease,updatethatcomponentbeforeconnectingtheAIPsinacascade.Forinformationonhowtoperformanupdate,refertothereleasenotesthatcorrespondtothelatestsoftwarerelease.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 129

Page 136: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Establish the Main AIP

ESTABLISH THE MAIN AIPSelectoneunittoactastheMainAIPforthecascadedunits,andconfigureitasdescribedin"UsingtheAIPElementManagementSoftware”onpage 27.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 130 ©February 2017 CommScope, Inc.

Page 137: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Designate Cascaded AIPs as Secondary Units in the AIP EMS

DESIGNATE CASCADED AIPS AS SECONDARY UNITS IN THE AIP EMS

ThefollowingproceduretellsyouhowtosetthemodeofthecascadedAIP(s)toSecondary.1 Followthestepsin"WebBrowserRequirementsandSetup”onpage 33.2 UseanEthernetCAT5cable(straightorcrossover)toconnectalaptoptotheCraftportontheACUofanAIPthatistobeaSecondaryAIP.3 OnyourPC,openanIEbrowser,andintheIEWebAddressbox,enterthefollowingURL:

https://192.168.2.1 4 WhentheAIP EMS Login windowopens:

a IntheUser Namebox,typetheusernameprovidedbyCommScopeorbytheNetworkAdministrator.Thedefaultusernameisadmin.b InthePasswordbox,typethepasswordprovidedbyCommScopeorbytheNetworkAdministrator.Thedefaultpasswordisadmin.c ClickLogin.

TheAIPEMSopenstotheGet Informationpage,whichisthedefaultview.NotethatbydefaulttheAIPisdesignateasaMainAIP.

5 IntheSystemTree,clickontheAIPicon.6 IntheSystemMenubar,clickSystem Information > Get Information.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 131

Page 138: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Designate Cascaded AIPs as Secondary Units in the AIP EMS

7 ClickSwitch to Secondary.

CAUTION! The Mode Setting option should be set only during initial setup. Do not try to change the Mode Setting option later.

NOTE: Once an AIP is set as a Secondary unit, the only way to change it back to being a Main unit is to connect a PC to the Craft port, log in to the AIP EMS, click on the AIP icon, click System Information > Get Information, and then click Switch to Main. However, as noted above, the Mode Setting option should be set only during initial setup. Do not try to change the Mode Setting option later.

8 ClickApply.9 NotethatfromnowontheSecondaryAIPCraftporthasastaticIPof192.168.0.1.ThePCmustbechangedtostaticmodetoworkwiththisCraftPort.See"TroubleshootingSecondaryUnits”onpage 135fordetailsonchangingthePCtostaticIPmode.

10 LogoutoftheAIPEMS.Youdonotneedtosetotherparametersatthistime.OnceyouconnectthisAIPwiththeMainAIP,youwillbeabletosetallAIPnamesandotherparametersatonetimeviatheMainAIP.11 DisconnecttheACUfromyourPC.12 RepeatthisprocedureforeachAIPinthecascadedsystemthatistobesetasaSecondaryAIP.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 132 ©February 2017 CommScope, Inc.

Page 139: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Physically Cascade the AIPs

PHYSICALLY CASCADE THE AIPS

UseCategory5cablewithRJ45connectorstoconnectoneAIPtoanother,usingtheExpansion1andExpansion2connectorsontheACUs.Aslongasyouhaveanuplinkanddownlinkconnection,itdoesn’tmatterwhichExpansion1orExpansion2connectorsthatyouuse.Forexample,youcanmakethefollowingconnections:• MainAIPACUExpansion2connectortofirstcascadedSecondaryAIPACUExpansion1connector• FirstSecondaryAIPACUExpansion2connectortosecondcascadedAIPACUExpansion1connector

Main AIP

1st CascadedSecondary AIP

ACU Expansion2 to ACU Expansion1

ACU Expansion2 to ACU Expansion1

2nd Cascaded Secondary AIP

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 133

Page 140: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Managing Cascaded AIPs

MANAGING CASCADED AIPS

OnceyouphysicallyconnecttheAIPsinacascade,theMainAIPwillfindthecascadedAIPs,andyouwillbeabletomanageallAIPsinthesystemwhenyoulogontotheMainAIP.

NOTE: It can take from 10 to 20 minutes for the Main AIP to find all connected Secondary AIPs.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 134 ©February 2017 CommScope, Inc.

Page 141: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Troubleshooting Secondary Units

TROUBLESHOOTING SECONDARY UNITS

IfaMainAIPfailstocommunicatewithacascadedSecondaryAIPorifyouneedtotroubleshootaSecondaryAIPindependentfromotherAIPswithinasystem,followthestepsinthissection.1 Followthestepsin"WebBrowserRequirementsandSetup”onpage 33.2 UseanEthernetCAT5cable(straightorcrossover)toconnectalaptoptotheCraftportontheACUoftheSecondaryAIPthatyouneedtotroubleshoot.3 ConfigureyourcomputerforastaticIPaddress.(HowyouconfigureyourPCmaydifferfromwhatisshownbelow.FollowthestepsapplicabletoyourPC’ssoftwareplatform.)

a OnyourPC,selectControl Panel > Network and Internet > Network Connections.b SelectLocal Area Connection > Properties.c SelectInternet Protocol Version 4,andthenselectProperties.d Entertheparametersshownbelow:

4 Openawebbrowser.5 InthewebbrowserURLbox,enterthefollowingIPaddress:https://192.168.0.16 WhentheAIP EMS Login windowopens:

a IntheUser Namebox,typetheusernameprovidedbyCommScopeorbytheNetworkAdministrator.Thedefaultusernameisadmin.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 135
Page 142: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Troubleshooting Secondary Units

b InthePasswordbox,typethepasswordprovidedbyCommScopeorbytheNetworkAdministrator.Thedefaultpasswordisadmin.

c ClickLogin.TheAIPEMSopenstotheGet Informationpage,whichisthedefaultview.

7 ConfiguretheAIP,asnecessary.8 Whenfinished,disconnecttheACUfromyourPC.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 136 ©February 2017 CommScope, Inc.

Page 143: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Chapter Topics Page

External Combiner/Splitter Shelf Product Overview..............................................................................................................................................136Combiner/Splitter Module for the External Combiner/Splitter Shelf ............................................................................................................137Deployment Examples for the External Combiner/Splitter Shelf...................................................................................................................138

Two Sectors, Each Sector Split into Two Zones ......................................................................................................................................139One Sector Split into Four Zones............................................................................................................................................................140Four Sectors with One Zone per Sector..................................................................................................................................................141

Installing an ECSS....................................................................................................................................................................................................142Install the AIP .................................................................................................................................................................................................142Install the ECSS into the Equipment Rack.......................................................................................................................................................142Connect the AIP CSU to the ECSS ...................................................................................................................................................................143Connect the ECSS to the DAS .........................................................................................................................................................................143

Connect the ECSS to a Prism/Spectrum Host Unit .................................................................................................................................143Connect the ECSS to a Fusion Main Hub ................................................................................................................................................145

ThisappendixdescribestheoptionalExternalCombiner/SplitterShelf(ECSS).

USING AN EXTERNAL COMBINER/SPLITTER SHELFA

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 137

Page 144: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

External Combiner/Splitter Shelf Product Overview

EXTERNAL COMBINER/SPLITTER SHELF PRODUCT OVERVIEW

Figure A-1showstheExternalCombiner/SplitterShelf(CommScopePartNumberAIP-ESC-1),whichprovidesincreasedflexibilitytothestandardAIPCSUconfigurations.Forexample,youcaninstallanExternalCombiner/SplitterShelf(ECSS)toprovideadditionalsectoringcapabilities.

Figure A-1. Fully-Loaded External Combiner/Splitter Shelf (CommScope PN 300001783488)TheECSSprovidesamodularapproachthatsupportsuptoeight4X1Combiner/SplitterModules.TheCombine/Splittermodulesallowyouto:• takeonetofourBTSfeeds(Sectors)andsplitthefeedsintotwotofourdifferentDASinputs(Zones),withamaximumoffourSectorscombinedandamaximumoffoursplitZones• takeuptofourBTSfeeds(Sectors)andfeedthemintooneZoneperSector.YoucannotusetheAIPCSUSelfMappingtoolwiththeECSS—manualconfigurationisrequired.

Front View

Back View

UL SUM

4X1

UL 1

UL 2

UL 3

UL 4

DL SUM

4X1

DL 1

DL 2

DL 3

DL 4

UL SUM

4X1

UL 1

UL 2

UL 3

UL 4

DL SUM

4X1

DL 1

DL 2

DL 3

DL 4

UL SUM

4X1

UL 1

UL 2

UL 3

UL 4

DL SUM

4X1

DL 1

DL 2

DL 3

DL 4

UL SUM

4X1

UL 1

UL 2

UL 3

UL 4

DL SUM

4X1

DL 1

DL 2

DL 3

DL 4

UL SUM

4X1

UL 1

UL 2

UL 3

UL 4

DL SUM

4X1

DL 1

DL 2

DL 3

DL 4

UL SUM

4X1

UL 1

UL 2

UL 3

UL 4

DL SUM

4X1

DL 1

DL 2

DL 3

DL 4

UL SUM

4X1

UL 1

UL 2

UL 3

UL 4

DL SUM

4X1

DL 1

DL 2

DL 3

DL 4

UL SUM

4X1

UL 1

UL 2

UL 3

UL 4

DL SUM

4X1

DL 1

DL 2

DL 3

DL 4

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 138 ©February 2017 CommScope, Inc.

Page 145: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

External Combiner/Splitter Shelf Product Overview

Combiner/Splitter Module for the External Combiner/Splitter ShelfTheCombiner/SplitterModule(CommScopepartnumberAIP-ESM-1,withfourQMAplugterminations)isdescribedbelow.

Ref # Component Cabling if Splitting a Sector into Separate Zones

Cabling if Maintaining One Sector per Zone

1, 2 The UL SUM port works with the paired DL SUM port to sum the uplink and downlink feed from the BTS to the 4x1 Combiner/Splitter Module.

Connect to the paired UL/DL ports on the AIP CSU.

Connect to the DAS• Prism and Spectrum: REV RF OUT

and FWD RF IN connectors• Fusion: UPLINK N and DOWNLINK

N connectors.

3, 4 The four UL ports work in pairs with the corresponding four DL ports. (The UL and DL ports are QMA connectors.)

Connect to the paired UL/DL ports on the AIP CSU.

Connect to the DAS• Prism and Spectrum: REV RF OUT

and FWD RF IN connectors• Fusion: UPLINK N and DOWNLINK

N connectors.

UL SUM

4X1

UL 1

UL 2

UL 3

UL 4

DL SUM

4X1

DL 1

DL 2

DL 3

DL 4

1 2

43

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 139

Page 146: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

External Combiner/Splitter Shelf Product Overview

Deployment Examples for the External Combiner/Splitter Shelf Figure A-2showsanexampleofusingtheAIPwithanExternalShelftocreateafour-Zonesplit,inwhich• Carrier1isusingtwoSectors,witheachSectorsplitintotwoZones• Carrier2isusingoneSectorsplitintofourZones• Carrier3isusingfourSectorswithoneZoneperSector.

Figure A-2. Example of a Four-Zone SplitForclarity,Figure A-2onlyshowsthecablingforUL(uplink)ports.Inanactualinstallation,theULandDLportsonanECSSarepaired.Therefore,inFigure A-2,thecablingfortheULportwouldbereproducedonthecorrespondingDLport.ThefollowingsectionsbreakthecablingforthethreecarriersshowninFigure A-2intoseparategraphics.

AIP CSU Tray in a Straight-Through Configura�on

AIP External Shelf

Carrier 1Carrier 1S1

Carrier 3Carrier 1S2

Carrier 3Carrier 2 S1

Carrier 3Carrier 3S1

Carrier 3Carrier 3S2

Carrier 3Carrier 3S3

Carrier 3Carrier 3S4

Zone 1DAS

Zone 2DAS

Zone 3DAS

Zone 4DASUL

DL

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 140 ©February 2017 CommScope, Inc.

Page 147: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

External Combiner/Splitter Shelf Product Overview

Two Sectors, Each Sector Split into Two ZonesFigure A-3andTable A-1showtherequiredUL/DLpairedcablingforCarrier1tohavetwoSectors,witheachSectorsplitintotwoZones.

Figure A-3. Paired UL and DL Cabling for an ECSS for Two Sectors, Each Sector Split into Two Zones

Table A-1. Slot and Port Pairings for Figure A-3

AIP CSU to ECSS Port Pairings ECSS Slot andUL/DL Port Pairings

AIP External UL/DL Portto DAS Zone Pairings

From AIP CSUUL/DL Port #

To ECSSUL/DL SUM Ports

on Slot #

Slot Pairings UL/DL Port Pairings From ECSS UL/DL SUM Ports on Slot

#

To DASZoneFrom To From To

Carrier 1Sector 1 1 1

1 5 1 4 5 1

1 6 2 4 6 2

Carrier 1Sector 2 2 2

2 7 1 4 7 3

2 8 2 4 8 4

AIP CSU Tray in a Straight-Through Configura�on

Carrier 1Carrier 1S1

ULDL

Uplink cabling

Downlink cabling

AIP External Shelf withSix Combiner/Spli�erModules

Carrier 1Carrier 1S2

Zone 1DAS

Zone 2DAS

Zone 3DAS

Zone 4DAS

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 141

Page 148: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

External Combiner/Splitter Shelf Product Overview

One Sector Split into Four ZonesFigure A-4andTable A-2showtherequiredUL/DLpairedcablingforCarrier2tosplitoneSectorintofourZones.

Figure A-4. Paired UL and DL Cabling for an ECSS for One Sector Split into Four Zones

Table A-2. Slot and Port Pairings for Figure A-4

AIP CSU to ECSS Port Pairings ECSS Slot andUL/DL Port Pairings

AIP External UL/DL Portto DAS Zone Pairings

From AIP CSUUL/DL Port #

To ECSSUL/DL SUM Ports

on Slot #

Slot Pairings UL/DL Port Pairings From ECSS UL/DL SUM Ports on Slot

#

To DASZoneFrom To From To

Carrier 2Sector 1

3 3

3 5 1 2 5 1

3 6 2 2 6 2

3 7 3 2 7 3

3 8 4 2 8 4

ULDL

AIP CSU Tray in a Straight-Through Configura�on

Carrier 3Carrier 2 S1

AIP External Shelf with Six Combiner/Spli�er Modules

Zone 1DAS

Zone 2DAS

Zone 3DAS

Zone 4DAS

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 142 ©February 2017 CommScope, Inc.

Page 149: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

External Combiner/Splitter Shelf Product Overview

Four Sectors with One Zone per SectorFigure A-4andTable A-3showtherequiredUL/DLpairedcablingforCarrier3tomaintainfourSectors,withoneZoneperSector.

Figure A-5. Paired UL and DL Cabling for an ECSS for Four Sectors with One Zone Per Sector

Table A-3. Slot and Port Pairings for Figure A-5

From AIP CSUUL/DL Port #

To ECSS Slot and UL/DL Port

AIP External UL/DL Port to DAS Zone Pairings

Slot UL/DLPort Pair

From ECSSUL/DL SUM Ports

on Slot #

To DASZone

Carrier 3 Sector 1 5 5 1 5 1

Carrier 3Sector 2 6 6 1 6 2

Carrier 3Sector 3 7 7 1 7 3

Carrier 3Sector 4 8 8 1 8 4

ULDL

AIP CSU Tray in a Straight-Through Configura�on

AIP External Shelf with Six Combiner/Spli�er Modules

Carrier 3Carrier 3S1

Carrier 3Carrier 3S2

Carrier 3Carrier 3S3

Carrier 3Carrier 3S4

Zone 1DAS

Zone 2DAS

Zone 3DAS

Zone 4DAS

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 143

Page 150: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Installing an ECSS

INSTALLING AN ECSSThissectiontellsyouhowtoaddanECSStoanAIPconfiguration.Itwillreferbacktoinstallationstepsfoundin"InstallingtheAIP”onpage 11.Foroptimalresults,followtheinstallationstepsintheorderinwhichtheyarepresented.

Install the AIPFollowthesectionsandcorrespondingstepsintheorderpresented.DonotconnecttheCSUuntiltoldtodoso.• "InstalltheAIPChassisinanEquipmentRack”onpage 13• "GroundtheAIPChassis”onpage 19• "InstallPowerWiring”onpage 20• "InstalltheCSUTray”onpage 22• "InstalltheBIU(s)”onpage 23• "ConnecttheBIUtotheBTS”onpage 24.

Install the ECSS into the Equipment RackTheAIPchassisrequires3RUofspace.USstandardandmetricmachinescrewsareincludedforrackmountingtheECSS.CAUTION! Follow the guidance in "Guard against Damage from Electro-Static Discharge” on page 12.

CAUTION! This is restricted access equipment. Only install it in a Network Telecommunications Facility. Only qualified service personnel should service and operate this equipment using appropriate tools.

CAUTION! The maximum ambient temperature for the AIP is 50º C (122º F).

CAUTION! Wet conditions increase the potential for receiving an electrical shock when installing or using electrically powered equipment. To prevent electrical shock, never install or use electrical equipment in a wet location or during a lightning storm.

CAUTION! When loading the AIP in a rack, make sure the mechanical loading of the rack is even to avoid a hazardous condition such as an unbalanced rack.

CAUTION! The rack should safely support the combined weight of all the equipment it holds.

NOTE: Vertical guides are recommended, but are not provided with the AIP. Vertical cable guide kits are available as separate items from CommScope. Contact a CommScope sales representative for further information (see "AppendixC:ContactsandUserDocumentation”onpage 151).

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 144 ©February 2017 CommScope, Inc.

Page 151: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Installing an ECSS

DothefollowingtoinstallanECSSintoanequipmentrack.1 PositiontheECSSinthespacedirectlybelowtheAIPintheequipmentrack.2 Secure(butdonottighten)theECSStotherackusingthefourmachinescrewsprovided(use#12-24orM6x10screws,whicheverisappropriate).3 Locatetwoverticalcableguides(notprovidedwiththeECSS).4 OntheECSS,backoutitsmountingscrewsjustenoughtoprovideclearanceforinstallationofthecableguides.5 Slideeachcableguideintopositionforinstallationandthensecurelytightenthecorrespondingmountingscrews.

Connect the AIP CSU to the ECSSHowyouconnecttheAIPCSUtotheECSSisdependentontheSector/Zonesplitsthatyouneedtocreate.1 Refertothe"DeploymentExamplesfortheExternalCombiner/SplitterShelf”onpage 140andyoursystemdesignplantodeterminehowyouneedtoconnecttheAIPCSUtotheECSS.2 Obtaintherequiredlengthsofhighperformance,flexible,lowloss50-ohmcoaxialcommunicationscable(RG-400orequivalent)forallcoaxialconnections.3 RoutetheuplinkanddownlinkcablesbetweentheAIPCSUandtheECSSandcuttotherequiredlength.Allowsufficientslackfordressingandorganizingcables.4 TerminateeachcablewithaQMA-Typemaleconnectorfollowingtheconnectorsupplier’srecommendations.5 ConnectapairoftheCSUULandDLportstotheappropriateULorULSUMportontheECSS.

Connect the ECSS to the DASFollowtheprocedurethatsupportstheDASsystemtowhichyouwillconnecttheECSS.• "ConnecttheECSStoaPrism/SpectrumHostUnit”onpage 145• "ConnecttheECSStoaFusionMainHub”onpage 147.

Connect the ECSS to a Prism/Spectrum Host Unit1 Refertothe"DeploymentExamplesfortheExternalCombiner/SplitterShelf”onpage 140andyoursystemdesignplantodeterminehowyouneedtoconnecttheECSStothePrism/SpectrumHostUnit.2 Obtaintherequiredlengthsofhighperformance,flexible,lowloss50-ohmcoaxialcommunicationscable(RG-400orequivalent)forallcoaxialconnections.3 RoutetheforwardandreversepathcoaxialcablesbetweenthePrism/SpectrumHostUnitandtheECSSperthesystemdesignplan,andthencuttotherequiredlength.AllowsufficientslackfordressingandorganizingcablesattheHostUnit.4 TerminateeachcablewithaQMA-Typemaleconnectorfollowingtheconnectorsupplier’srecommendations.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 145

Page 152: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Installing an ECSS

5 ConnecttheREVRFOUTconnectoronaHostDARTfrontpaneltotheappropriateULorULSUMportontheECSS.6 ConnecttheFWDRFINconnectoronaHostDARTfrontpaneltotheappropriateDLorDLSUMportontheECSS.TheDLorDLSUMportmustbethepairtotheULorULSUMportusedinStep 5onpage 146.

7 DressandsecurecablestotherightsideofthePrism/SpectrumHostUnit.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 146 ©February 2017 CommScope, Inc.

Page 153: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Installing an ECSS

Connect the ECSS to a Fusion Main Hub1 Refertothe"DeploymentExamplesfortheExternalCombiner/SplitterShelf”onpage 140andyoursystemdesignplantodeterminehowyouneedtoconnecttheECSStothePrism/SpectrumHostUnit.2 Obtaintherequiredlengthsofhighperformance,flexible,lowloss50-ohmcoaxialcommunicationscable(RG-400orequivalent)forallcoaxialconnections.3 RoutetheforwardandreversepathcoaxialcablesbetweentheFusionMainHubandtheECSS(persystemdesignplan)andcuttotherequiredlength.AllowsufficientslackfordressingandorganizingcablesattheFusionMainHub.4 TerminateeachcablewithaQMA-Typemaleconnectorfollowingtheconnectorsupplier’srecommendations.5 ConnectanUPLINKNconnectorontheFusionMainHubtotheappropriateULorULSUMportontheECSS.6 ConnectaDOWNLINKNconnectorontheFusionMainHubtotheappropriateDLorDLSUMportontheECSS.TheDLorDLSUMportmustbethepairtotheULorULSUMportusedinStep 5onpage 147.

Alarms AC Power

Band 1 Band 2 Band 3

UL1 UL2 UL3

DL1 DL2 DL3

Uplink N connectors

Downlink N connectors

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 147

Page 154: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Installing an ECSS

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 148 ©February 2017 CommScope, Inc.

Page 155: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Chapter Topics Page

RF Performance......................................................................................................................................................................................................148Technical Specifications .........................................................................................................................................................................................149

AIP Chassis......................................................................................................................................................................................................149AIP BIUs ..........................................................................................................................................................................................................149AIP CSU ...........................................................................................................................................................................................................150External Combiner/Splitter Shelf (ECSS).........................................................................................................................................................150

Standards Certification...........................................................................................................................................................................................151

SPECIFICATIONSB

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 149

Page 156: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

RF Performance

RF PERFORMANCE

Supported frequencies and bands E-UTRA Band/Other Downlink (TX)Frequency (MHz)

Uplink (RX)Frequency (MHz)

Band 4 — 2100 AWS 2110 - 2155 1710 - 1755

Band 5 — 850 Cell 869 - 894 824 - 849

Band 12 — 700 ABC 728 - 746 698 - 716

Band 13 — 700 UC 746 - 757 776 - 787

Band 25 — 1900 PCS 1930 - 1995 1850 - 1915

Band 27 — 800 ESMR/iDEN 851 - 869 806 - 824

Band 30 — 2300 WCS 2350 - 2360 2305 - 2315

Band 41 — 2500 TDD 2496 - 2690 2496 - 2690

AIP

Passband Ripple (TX and RX) <2 dB over temperature range

PIM performance -160 dBc @ 2X43 dBm (-117 dBm @ 2X43 dBm)

Input power range 0.25 to 100Watts RMS composite power

Overpower protection DAS interrupts RF path for input power >100Watts over 5 seconds

Downlink Gain range -75 to -5 dB

Power balancing Supports user configurable downlink ALC thresholds for power balancing neutral host arrangements

Uplink Gain Range -30 to 0 dB

Input Return Loss 18 dB

Output Return Loss 14 dB

AIP Downlink/Uplink Minimum Attenuation

CSU ConfigurationCSU Loss:

Uplink and Downlink (dB)

BIU DownlinkMinimum (dB)

BIU UplinkMinimum (dB)

Downlink Minimum Loss:

BIU and CSU (dB)

UplinkMinimum Loss:

BIU and CSU (dB)

Straight Through 2 5 0 7 2

2x1 5 5 0 10 5

3x1 6.7 5 0 11.7 6.7

4x1 8 5 0 13 8

External Combiner/Splitter Shelf (ECSS)

Maximum Downlink Input Power

+30 dBm

Maximum Insertion Loss 7.5 dB

Return Loss 14 dB

Maximum Flatness 1 dB from 698 to 2700 MHz, 0.25 dB for each band

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 150 ©February 2017 CommScope, Inc.

Page 157: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Technical Specifications

TECHNICAL SPECIFICATIONS

AIP Chassis

AIP BIUs

Dimensions Inches Millimeters

Width (includes mounting tabs) 19 482.6

Depth (includes fans) 20 508

Height (includes CSU) 6 RUs

Weight Pounds Kilograms<110 lbs 49.895

Electrical

Power Consumption 55 Watts

Power Supply 48 Vdc

Monitoring and Management Web and SNMP over 10/100/1000 Ethernet Network via the ACU

Environmental

Operating Temperature -5 °C to +50 °C

Storage Temperature -40 °C to +85 °C

Humidity 5% to 90%

* Weight is for a fully configured AIP, which comprises the AIP chassis, one ACU, eight BIUs, and one CSU.

Dimensions Inches Millimeters

Depth (includes handle) 18.62 47.295

Width 1.89 48

Height 7.87 200

Weight (fully loaded) Pounds Kilograms<7 lbs 3.175

Electrical

Power Consumption 7 Watts

Power Supply 48 Vdc

Environmental

Operating Temperature -5 °C to +50 °C

Storage Temperature -40 °C to +85 °C

Humidity 5% to 90%

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 151

Page 158: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Technical Specifications

AIP CSU

External Combiner/Splitter Shelf (ECSS)

Dimensions Inches Millimeters

Depth (includes handle) 18.62 47.295

Width 17.17 436

Height 2.25 57.1

Weight Pounds Kilograms<20 lbs 9.072

Electrical

Power Consumption 1 Watt

Power Supply 48 Vdc

Environmental

Operating Temperature -5 °C to +50 °C

Storage Temperature -40 °C to +85 °C

Humidity 5% to 90%

Dimensions Inches Millimeters

Width (includes mounting tabs) 19 482.6

Depth (includes fans) 20 508

Height (includes CSU) 3 RUs

Weight* Pounds Kilograms10.5 4.8

Environmental

Operating Temperature -5 °C to +50 °C

Storage Temperature -40 °C to +85 °C

Humidity 5% to 90%

* Weight is for a fully configured External Shelf with eight Combiner/Splitter Modules.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 152 ©February 2017 CommScope, Inc.

Page 159: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Standards Certification

STANDARDS CERTIFICATION

FCC:ThisequipmentcomplieswiththeapplicablesectionsofTitle47CFRPart15.IC:ThisequipmentcomplieswiththeapplicablesectionsofRSS-131.Theterm“IC:”beforetheradiocertificationnumberonlysignifiesthatIndustryCanadaTechnicalSpecificationsweremet.CAUTION! Modifications not expressly approved by the party responsible for compliance could void the user's

authority to operate the equipment.

UL/CUL:ThisequipmentcomplieswithULandCUL60950-1StandardforSafetyforInformationTechnologyEquipment,includingElectricalBusinessEquipment.EMCStandards:FCCpart15classASafetyStandards:ThisequipmentcomplieswithIEC60950-1,2NDEdition+Amendment1(CEmarked)andwithUL60950-1,2NDEdition+Amendment1(FilenumberE174166)(USAandCanada)

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 153

Page 160: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Standards Certification

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 154 ©February 2017 CommScope, Inc.

Page 161: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Chapter Topics Page

Contacting Global Technical Support .....................................................................................................................................................................154Telephone Helplines.......................................................................................................................................................................................154Online Support ...............................................................................................................................................................................................154

DCCS Technical Training .........................................................................................................................................................................................155Accessing User Documentation..............................................................................................................................................................................156

Accessing Prism User Documentation............................................................................................................................................................156Accessing Spectrum User Documentation .....................................................................................................................................................156Accessing InterReach Fusion User Documentation........................................................................................................................................157

ThischaptertellsyouhowtocontacttheCommScopeDistributedCoverageandCapacitySolutions(DCCS)TechnicalSupportteam.Supportisavailable7daysaweek,24hoursaday.

DCCS GLOBAL TECHNICAL SUPPORTC

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 155

Page 162: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Contacting Global Technical Support

CONTACTING GLOBAL TECHNICAL SUPPORT

ThischaptertellsyouhowtocontacttheCommScopeDistributedCoverageandCapacitySolutions(DCCS)TechnicalSupportteam.Supportisavailable7daysaweek,24hoursaday.TELEPHONE HELPLINESUsethefollowingHelplinetelephonenumberstogetlivesupport,24hoursaday:

ONLINE SUPPORTTogototheCommScopeDCCSSupportRequestwebsitefromwhichyoucaninitiateaTechnicalSupportticket,dooneofthefollowing:• ScantheQRCodetotheright.• IfviewingthisdocumentonlineasaPDF,clickonthefollowingURLlink:http://www.commscope.com/wisupport• EntertheprecedingURLintoyourwebbrowser,andthenpressENTERonyourkeyboard.

24x7 +1888-297-6433(TollfreeforU.S.andCanada)EMEA 8:00-17:00 (UTC +1) +80073732837(TollfreeforpartsofEMEAandAustralia)+49909969333(Tollchargeincurred)CallstoanEMEAHelplineoutsideofthe8:00to17:00timeframewillbeforwardedtothe24x7Helpline.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 156 ©February 2017 CommScope, Inc.

Page 163: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

DCCS Technical Training

DCCS TECHNICAL TRAINING 1 ToaccesstrainingontheonlineCommScopeDASandSmallCellInstitute,dooneofthefollowing:

• ScantheQRCodetotheright.• IfviewingthisdocumentonlineasaPDF,clickonthefollowingURLlink.http://www.commscopetraining.com/courses/dassc/• EntertheprecedingURLintoyourwebbrowser,andthenpressENTERonyourkeyboard.

2 Reviewthecourseslistedinseparatecoursepanels;forfurtherinformationonacourse,clickitsFull detailsbutton.Instructor-ledcoursesareconductedinNorthAmericaandEurope.Beforechoosingacourse,pleaseverifytheregion.3 Toviewthecoursescheduleandregister,clickCourse Registrationatthetopofthecoursepage;thisopensthePartner Learning Center Loginpage.

• Ifyouhaveanaccount,enteryourUsernameandPassword,andthenclickLogin.(ClickontheResetPasswordlinkifyoudonothaveyourlogininformation.)

• Ifyoudon'thaveanaccount,clickontheCreate New User AccountlinkundertheLoginbutton,andfollowtheprompts.Onceyouhaveloggedin,youwillseealistofavailableclassdates.4 ClickthedateyoupreferandselecttheEnrollorRegisterNowbuttontoenroll.Followthepromptsthroughthepaymentprocess.5 ClickeithertheAvailable TrainingorCalendartabtoviewothertrainingcourses.Fortrainingrelatedquestions,pleasecontacttheCommScopeDASandSmallCellInstituteatoneofthefollowingemails,asappropriateforyourlocation:Americas: [email protected]: [email protected]

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 157

Page 164: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Accessing User Documentation

ACCESSING USER DOCUMENTATION

ThefollowingsectionstellyouhowtoaccessuserdocumentationforCommScopeDCCSproductlines.• "AccessingPrismUserDocumentation”onpage 158• "AccessingSpectrumUserDocumentation”onpage 158• "AccessingInterReachFusionUserDocumentation”onpage 159.

Accessing Prism User Documentation 1 ToopentheCommScopeDCCSCustomerPortal,fromwhichyouaccesstheFlexWavePrismuserdocumentation,dooneofthefollowing.

• ScantheQRCodetotheright.• IfviewingthisdocumentonlineasaPDF,clickonthefollowingURLlink.https://www.mycommscope.com• EntertheprecedingURLintoyourwebbrowser,andthenpressENTERonyourkeyboard.

2 AccesstotheDCCSCustomerPortalrequiresauseraccount.OntheSign Inpage,dooneofthefollowing:• Ifyouhaveanaccount,enteryourEmail addressandPassword,andthenclickSign In.• Ifyoudon’thaveanaccount,clickNew user registration,andfollowtheprompts.

3 ClickDCCS.4 Selectyoursite,andthenclickFlexWave Prism.ThePrismuserdocumentationislistedundertheManualsandInstallation Guidesheadings.5 Clickonthetitleofanydocumenttoopenit.

Accessing Spectrum User Documentation 1 ToaccesstheFlexWaveSpectrumuserdocumentation,dooneofthefollowing:

• ScantheQRCodetotheright.• IfviewingthisdocumentonlineasaPDF,clickonthefollowingURLlink.http://www.commscope.com/collateral/FlexWave_Spectrum• EntertheprecedingURLintoyourwebbrowser,andthenpressENTERonyourkeyboard.

2 Clickonthetitleofanydocumenttoopenit.

FlexWave® Active Integration Panel Installation and Configuration Guide FWPP-518-01Page 158 ©February 2017 CommScope, Inc.

Page 165: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter

Accessing User Documentation

Accessing InterReach Fusion User DocumentationYoucanaccesstheInterReachFusionuserdocumentationontheCommScopeFusionCollateralwebsite,asdescribedbelow.1 ToaccesstheInterReachFusionuserdocumentation,dooneofthefollowing:

• ScantheQRCodetotheright.• IfviewingthisdocumentonlineasaPDF,clickonthefollowingURLlink.http://www.commscope.com/collateral/interreach_fusion• EntertheprecedingURLintoyourwebbrowser,andthenpressENTERonyourkeyboard.

2 Clickonthetitleofanydocumenttoopenit.

FWPP-518-01 FlexWave® Active Integration Panel Installation and Configuration Guide©February 2017 CommScope, Inc. Page 159

Page 166: FlexWave Active Integration Panel - commscope.com€¦ · BTS Tx/Rx Sample Port Status Power AIP-BIU BTS ... View Current Alarms ... • provides an internal pre-configured Combiner/Splitter