FLEXIBLE - Nader Pardaz Co. | شرکت مهندسی نادرپرداز BATTERY BOX BTS AC DIESEL...

16

Transcript of FLEXIBLE - Nader Pardaz Co. | شرکت مهندسی نادرپرداز BATTERY BOX BTS AC DIESEL...

Page 1: FLEXIBLE - Nader Pardaz Co. | شرکت مهندسی نادرپرداز BATTERY BOX BTS AC DIESEL GENSET RECTIFIER BATTERY BOX BTS TELECOM TOWER A B C LAYOUT OF TYPICAL TELECOM SITE
Page 2: FLEXIBLE - Nader Pardaz Co. | شرکت مهندسی نادرپرداز BATTERY BOX BTS AC DIESEL GENSET RECTIFIER BATTERY BOX BTS TELECOM TOWER A B C LAYOUT OF TYPICAL TELECOM SITE

FLEXIBLE ENERGY SOLUTION FORTELECOM OPERATORS

PARTNER

Page 3: FLEXIBLE - Nader Pardaz Co. | شرکت مهندسی نادرپرداز BATTERY BOX BTS AC DIESEL GENSET RECTIFIER BATTERY BOX BTS TELECOM TOWER A B C LAYOUT OF TYPICAL TELECOM SITE

2 41 ACGENERATORS

3 DC-HPUHYBRID POWER

GREENSOLUTIONS

DCGENERATORS

2G 3G LTE FEMTO

TELECOM POWER SOLUTIONSTELECOM POWER SOLUTIONS

Our developed Power Solutions are the result of a tight co-operation of the Ascot LAB team with the most important Telecom Operators.

ASCOT LAB DEVELOPS YOUR TELECOM SOLUTIONSAS

COT

LAB

TEAM

EVOLUTION OF ASCOT PRODUCTS & TELECOM TECHNOLOGIES

PRODUCTSDESIGNEDTO REDUCECAPEX & OPEX

of FLEXIBLE and MODULAR ENERGY SOLUTIONS that properly fit to the telecom industry needs. SIMPLICITY and EASY TO OPERATE are the Principles that inspire all the design of the Ascot products built as smart and flexible power solution to save CAPEX and OPEX .

With more than 15th years of experience, working closely with telecom operators, the Ascot “Research and Development Team” has developed a special skills and attitude in understanding the customers needs COMING FROM the field, that permits a continuous development

Page 4: FLEXIBLE - Nader Pardaz Co. | شرکت مهندسی نادرپرداز BATTERY BOX BTS AC DIESEL GENSET RECTIFIER BATTERY BOX BTS TELECOM TOWER A B C LAYOUT OF TYPICAL TELECOM SITE

A B

E

C D

1 ACGENERATORS

TELECOM PACKAGE

2GR

ECTI

FIER

BAT

TERY

BO

X

BTS

AC DIESEL GENSETRECTIFIERBATTERY BOX BTSTELECOM TOWER

ABC

LAYOUT OF TYPICAL TELECOM SITEdirect connection to BTS

DE

Page 5: FLEXIBLE - Nader Pardaz Co. | شرکت مهندسی نادرپرداز BATTERY BOX BTS AC DIESEL GENSET RECTIFIER BATTERY BOX BTS TELECOM TOWER A B C LAYOUT OF TYPICAL TELECOM SITE

AC DIESEL GENERATING SETSAC DIESEL GENERATING SETS

This Power range Solution,

is today considered

inefficient in terms of

OPEX comparing to the

new proposed solutions; it

remains primarily indicated

to power the traditional

telecom site, indoor or

outdoor, when the Mains

(local grid) has a stable

presence (80-95%) and the

AC Generators are used

only in Emergency case.

RANGE7-40 KVA TELECOM

USED AS STANDBY TO THE MAINS

This Power range Solution, is

still today a valid compromise

as back up to the Mains and

Particularly indicated to power

Switching/Data/Core Centres

that are sensitive part of the

Telecom Industry.

RANGE250 - 2000 KVA FOR SWITCH CENTER

USED AS STANDBY or CONTINUOUS DUTY IN EMERGENCIES TO THE MAINS

SINGLE DUAL 1+1

Page 6: FLEXIBLE - Nader Pardaz Co. | شرکت مهندسی نادرپرداز BATTERY BOX BTS AC DIESEL GENSET RECTIFIER BATTERY BOX BTS TELECOM TOWER A B C LAYOUT OF TYPICAL TELECOM SITE

2 DCGENERATORS

A C

D

B

TELECOM PACKAGE

DC GENERATORASCOT BATTERY BOXBTSTELECOM TOWER

ABC

LAYOUT OF TYPICAL TELECOM SITEdirect connection to BTS

D

3G

BTS

Page 7: FLEXIBLE - Nader Pardaz Co. | شرکت مهندسی نادرپرداز BATTERY BOX BTS AC DIESEL GENSET RECTIFIER BATTERY BOX BTS TELECOM TOWER A B C LAYOUT OF TYPICAL TELECOM SITE

DC GENERATORDC GENERATORS

DC Generator is the most economical solution to supply direct DC current to telecom site. Thanks to the PMG technology the system is ligth and easy to carry to the unreachable site. Because of its lightness it is mainly indicated for temporarily site.

Built by Ascot with PMG technology and running at variable speed between 2000-2900 rpm, it guarantees a concrete saving in OPEX.

DC GENERATOR PMG 7-10 KW

TO SUPPLY DC ENERGY FOR YOUR UNREACHABLE SITE

DC GENERATOR DIODE 7-20 KW

FOR CUSTOMIZED HYBRID SOLUTION (BEST BENEFIT WHEN THE MAINS IS NOT PRESENT)

Comparing to the AC Generators, the DC Generators are more efficient because, in the chain of the power supply, permit to:

Reduce the CAPEX in terms of acquisition cost of the Rectifier; Have more reliability because it has one less component; A consistent saving in terms of maintenance OPEX having one less element.

Built by Ascot with DIODE technology and running at variable speed between 1400-1800 rpm, it guarantees a concrete saving in OPEX.

Page 8: FLEXIBLE - Nader Pardaz Co. | شرکت مهندسی نادرپرداز BATTERY BOX BTS AC DIESEL GENSET RECTIFIER BATTERY BOX BTS TELECOM TOWER A B C LAYOUT OF TYPICAL TELECOM SITE

3 DC-HPUHYBRID POWER

A B

C

TELECOM PACKAGE

LTE

BTS

DC-HPUBTSTELECOM TOWER

ABC

LAYOUT OF TYPICAL TELECOM SITEdirect connection to BTS

Page 9: FLEXIBLE - Nader Pardaz Co. | شرکت مهندسی نادرپرداز BATTERY BOX BTS AC DIESEL GENSET RECTIFIER BATTERY BOX BTS TELECOM TOWER A B C LAYOUT OF TYPICAL TELECOM SITE

MODULAR DC-HPU FOR 1-3 OPERATORS

DC-HPU HYBRID POWER UNITDC-HPU HYBRID POWER UNIT

68% reduction in fuel consumption

81% saving in running hours

8 months free maintenance

Designed in different models to accommodate all needs of telecom operators

The INNOVATIVE & PATENTED

DC-HPU is an INTEGRATED

PLUG & PLAY PACKAGE

designed to be directly

plugged @48Vdc to the

TELECOMMUNICATION SITE .

FOR LOAD 100-10.000 W

BEST BENEFIT WHEN THE MAINS IS NOT PRESENT or AVAILABE less then 12 hours

FLEXIBLE SOLUTION FORINDEPENDENT TOWER OPERATORS

Unique savings up to:

An integration of technical elements remotely controlled by Ascot Remote Control

The Principle behind the

solution is based on a smart

flexible power solution with

MINIMUM INITIAL CAPEX ,

capable TO BE EXPANDED

GRADUALLY in conjunction

with the acquisition of the

tenancy agreement.

Max Fuel Consumption at 100 %

Max Running Hours at 100 %

Service Interval

Interval Fuel Refuelling*

19 Lt/day

4 hours/day

8 months

100 days

37 Lt/day 51 Lt/day

6 hours/day 8 hours/day

6 months 4 months

50 days 36 days

Modular DC-HPU 48/24KW 1-3 OPERATORS

* based on 2000 litres tank

Page 10: FLEXIBLE - Nader Pardaz Co. | شرکت مهندسی نادرپرداز BATTERY BOX BTS AC DIESEL GENSET RECTIFIER BATTERY BOX BTS TELECOM TOWER A B C LAYOUT OF TYPICAL TELECOM SITE

4 GREENSOLUTIONS

FEMTO

Renewable energy is derived from natural resources, such as solar energy, wind energy and water resources, including wave power and geothermal heat. In 2006 approximately 18% of final energy consumption on a global level was derived from renewable energy sources, with 13% coming from biomass material and 3% from water power. As regards generating electrical energy, about 18% comes from renewable sources, with 15%

coming from water power and 3.4% from other renewable sources.

It is part of Ascot’s philosophy to contribute to the development of clean and sustainable energy in protecting and preserving the global environment.

Ascot is totally committed to the development of new solutions to challenges which can offer the prospect of a better life to people the world over.

Page 11: FLEXIBLE - Nader Pardaz Co. | شرکت مهندسی نادرپرداز BATTERY BOX BTS AC DIESEL GENSET RECTIFIER BATTERY BOX BTS TELECOM TOWER A B C LAYOUT OF TYPICAL TELECOM SITE

GREEN COMBY SOLUTIONSGREEN COMBY SOLUTIONS

COMBI: GRID/WIND/SOLAR/ DC HPU

AUTOMATICALLY SWITCH TO THE CHEAPEST SOURCE OF ENERGY DC HPU HYBRID POWER UNIT IN COMBINATION WITH GRID / SOLAR PANEL / WIND / DC GENERATORS

The “Wind /Solar/DC HPU Combi” model is a typical situation in which the Battery Bank are recharged Automatically by the cheapest Energy source.Here is a typical situation of saving based on DC HPU system that will run for 4 hours per days in Active mode (Engine ON) and 20 hours per day in Sleeping Mode (Battery ON).

Day with limited sun and no wind:• Contribution of the Solar Panel = 0 Watt / 0 hours

• Contribution of the Wind Power = 0 Watt / 0 hours

• Contribution of Active mode (engine ON) = 4 hours per day

• Contribution of Battery Bank = 20 hours per day

Fully sunny and windy day:• Contribution of the Solar Panel = between 1 and 2 hours

• Contribution of the Wind Power = 1 hours

• Contribution of Active mode (engine ON) = between 1-2 hours per day

• Contribution of Battery Bank = 20 hours per day

Page 12: FLEXIBLE - Nader Pardaz Co. | شرکت مهندسی نادرپرداز BATTERY BOX BTS AC DIESEL GENSET RECTIFIER BATTERY BOX BTS TELECOM TOWER A B C LAYOUT OF TYPICAL TELECOM SITE

NOW YOU CAN MONITOR IN REAL TIME YOUR OPEX

Page 13: FLEXIBLE - Nader Pardaz Co. | شرکت مهندسی نادرپرداز BATTERY BOX BTS AC DIESEL GENSET RECTIFIER BATTERY BOX BTS TELECOM TOWER A B C LAYOUT OF TYPICAL TELECOM SITE

Remote Control Interface for DC-HPU 48/7-600

ASCOT REMOTE CONTROL SYSTEMASCOT REMOTE CONTROL SYSTEM

NOW YOU CAN CONTROL YOUR OPEX

WHAT YOU NEED TO CONTROL YOUR SITE:

DC-HPU with installed SIM CARD

Any standard PC Connected in INTERNET to log on http://ascot-trial.dyndns.org/

Go on line and check your Opex

The control of the OPeration

EXpenses is one of the critical

issue for the telecom operators.

Experience the access to the

on-line trial of a DC-HPU

installed in Italy from your

computer and you will be

able to access to different

pages and to control HPU,

Check real time DC HPU StatusLive from site web cam

Historical trend of fuel level, Output Vdc, Output Idc, etc..

ENGINE, BATTERY, FUEL, SITE,

LOGGER, SETUP as showed

below.

Page 14: FLEXIBLE - Nader Pardaz Co. | شرکت مهندسی نادرپرداز BATTERY BOX BTS AC DIESEL GENSET RECTIFIER BATTERY BOX BTS TELECOM TOWER A B C LAYOUT OF TYPICAL TELECOM SITE
Page 15: FLEXIBLE - Nader Pardaz Co. | شرکت مهندسی نادرپرداز BATTERY BOX BTS AC DIESEL GENSET RECTIFIER BATTERY BOX BTS TELECOM TOWER A B C LAYOUT OF TYPICAL TELECOM SITE

ACGENERATORS

DC-HPUHYBRID POWER

COMPARISON DC-HPU / AC GENSETCOMPARISON DC-HPU / AC GENSET

SAVE 15 MILLIONS OF US $ OF FUEL PER YEAR*

15 MILLIONS OF US $ SAVED PER YEAR

* Based on 1000 sites. 1Lt = 1$

DC-HPU

Average load Engine Running Hours per days

(Hours/day

Engine Running Hours per days

(Hours/day

Litres saved per day

Litres saved per month

Litres saved per year

Fuel Consumption per day

(Litres/day)

Fuel Consumption per day

(Litres/day)

AC GENSET FUEL SAVING

1,2 kw2kw3kw4kw

5,26,06,26,3

24242424

12,419,429,136,5

33506775

-20,6-30,6-37,9-38,5

-619-917-1138-1154

-7535-11159-13844-14038

Page 16: FLEXIBLE - Nader Pardaz Co. | شرکت مهندسی نادرپرداز BATTERY BOX BTS AC DIESEL GENSET RECTIFIER BATTERY BOX BTS TELECOM TOWER A B C LAYOUT OF TYPICAL TELECOM SITE