PowerPoint Presentation

Fixed Ladders - Roof Ladders Caged Ladders: OSHA, ANSI Design Criteria and ApplicationsPartial list of Design Criteria and Code Considerations contained in slides.

4188 East Andrew Johnson HighwayMorristown, TN 37814800-225-7814info@precisionladders.comFL Series Fixed Ladders - Roof Ladders - Caged Ladders (left)SL Series Ships Ladder (right) Precision Ladders 2015

1

There are 3 Types of Fixed Vertical Ladders:

To a Hatch To a Walk-Thru Side Exit = Overshoot

.2

Ladder Terminates at Exit

3

Fixed Ladders with Walk-Thrus Walk-thru = Roof-over or Side Rail Extension Exits = straight ahead / between the side rails Access = intermediate level above Access = catwalk

4

Fixed Ladders with Walk-Thrus for Platforms and Landings Platform to cross over parapet walls Return ladder on the backside if necessary 6 above wall height

5

Ladder Extensions at Exits

6

Applicable Codes andCode Provisions Partial list of Design Criteria and Code Considerations contained in slides.

Fixed Ladders

7

Applicable Codes for Fixed Ladders OSHA-Occupational Safety & Health Admin. ANSI-American National Standards Institute

OSHA and ANSI code are similar. The more stringent code element in each is used as a guideline in this presentation.

National codes OSHA 1910.27 www.OSHA.gov ANSI A14.3www.ANSI.org

Websites offer easy code reference

Note: Some states may have special code requirements

8

Applicable Codes for Fixed LaddersOSHA refers to ANSI but alters its version of the code.Best Practice:Select a manufacturer who builds to the more stringent of the two codes or the overlap of the two codes.Some states may have special code requirements.Manufactures will advise you on exact requirements.

9

Safety Cages (OSHA) Cages provided on ladders more than 20 Recommended on shorter ladders in dangerous locations Cages extend past exit point Cages start between 7 and 8 above ground Cage sizes and shapes set by code

10

Safety Cages (ANSI) Cages provided on ladders more than 24 Recommended on shorter ladders in dangerous locations Cages extend past exit point Cages start between 7 and 8 above ground Cage sizes and shapes are set by code

11

Landing Platforms Landings provided for each 30 of height except where no cage, well, or ladder safety device is provided Rest platforms offset at each level Rest platforms have handrails and toe boards on all exposed sides Landing minimum 48 length and 30 width Ladder accessing landing have rung level with platform

12

Fixed Ladders - Roof Ladders Caged Ladders: OSHA, ANSI Design Criteria and ApplicationsPartial list of Design Criteria and Code Considerations contained in slides.4188 East Andrew Johnson HighwayMorristown, TN 37814800-225-7814info@precisionladders.comFL Series Fixed Ladders - Roof Ladders - Caged Ladders (left)SL Series Ships Ladder (right) Precision Ladders 2015