Firestone Building Products EPDM Training – Base Tie-in and Roof Edge.
-
Upload
amice-mcbride -
Category
Documents
-
view
219 -
download
0
Transcript of Firestone Building Products EPDM Training – Base Tie-in and Roof Edge.
![Page 1: Firestone Building Products EPDM Training – Base Tie-in and Roof Edge.](https://reader035.fdocuments.net/reader035/viewer/2022062519/5697c0041a28abf838cc410b/html5/thumbnails/1.jpg)
Firestone Building Products
EPDM Training – Base Tie-in and Roof Edge
![Page 2: Firestone Building Products EPDM Training – Base Tie-in and Roof Edge.](https://reader035.fdocuments.net/reader035/viewer/2022062519/5697c0041a28abf838cc410b/html5/thumbnails/2.jpg)
Details: Base Tie-In – RPF Strip, 2” plates to deck
![Page 3: Firestone Building Products EPDM Training – Base Tie-in and Roof Edge.](https://reader035.fdocuments.net/reader035/viewer/2022062519/5697c0041a28abf838cc410b/html5/thumbnails/3.jpg)
Details: Base Tie-In – RPF Strip, 2” plates to wall.
![Page 4: Firestone Building Products EPDM Training – Base Tie-in and Roof Edge.](https://reader035.fdocuments.net/reader035/viewer/2022062519/5697c0041a28abf838cc410b/html5/thumbnails/4.jpg)
Details: Base Tie-In – RPF Strip, Batten to deck
![Page 5: Firestone Building Products EPDM Training – Base Tie-in and Roof Edge.](https://reader035.fdocuments.net/reader035/viewer/2022062519/5697c0041a28abf838cc410b/html5/thumbnails/5.jpg)
Details: Base Tie-In – RPF Strip, Batten to wall.
![Page 6: Firestone Building Products EPDM Training – Base Tie-in and Roof Edge.](https://reader035.fdocuments.net/reader035/viewer/2022062519/5697c0041a28abf838cc410b/html5/thumbnails/6.jpg)
Details: Base Tie-In – 2” plates
![Page 7: Firestone Building Products EPDM Training – Base Tie-in and Roof Edge.](https://reader035.fdocuments.net/reader035/viewer/2022062519/5697c0041a28abf838cc410b/html5/thumbnails/7.jpg)
Details: Base Tie-In – 2” plates to wall/curb
![Page 8: Firestone Building Products EPDM Training – Base Tie-in and Roof Edge.](https://reader035.fdocuments.net/reader035/viewer/2022062519/5697c0041a28abf838cc410b/html5/thumbnails/8.jpg)
Details: Base Tie-InImproper Application
![Page 9: Firestone Building Products EPDM Training – Base Tie-in and Roof Edge.](https://reader035.fdocuments.net/reader035/viewer/2022062519/5697c0041a28abf838cc410b/html5/thumbnails/9.jpg)
Details: Base Tie-InProper Application
![Page 10: Firestone Building Products EPDM Training – Base Tie-in and Roof Edge.](https://reader035.fdocuments.net/reader035/viewer/2022062519/5697c0041a28abf838cc410b/html5/thumbnails/10.jpg)
Base Tie-In Tips• Base tie-in should have the proper fastening rate per roof design. • Base tie-ins can be made to either the deck or into the approved adjacent vertical surface. • Do not over-drive plates and fasteners.• Be sure to prime all mating surfaces within the base tie-in. • Use caution when rolling in the base tie-in areas. • If a deck obstruction occurs, base tie-ins can be moved a maximum of 6” from the wall or parapet.
![Page 11: Firestone Building Products EPDM Training – Base Tie-in and Roof Edge.](https://reader035.fdocuments.net/reader035/viewer/2022062519/5697c0041a28abf838cc410b/html5/thumbnails/11.jpg)
Details: Roof Edge Corner w/ T-Joint
![Page 12: Firestone Building Products EPDM Training – Base Tie-in and Roof Edge.](https://reader035.fdocuments.net/reader035/viewer/2022062519/5697c0041a28abf838cc410b/html5/thumbnails/12.jpg)
Details: Roof Edge w/ QS endlap splice overlap
![Page 13: Firestone Building Products EPDM Training – Base Tie-in and Roof Edge.](https://reader035.fdocuments.net/reader035/viewer/2022062519/5697c0041a28abf838cc410b/html5/thumbnails/13.jpg)
Details: Roof Edge w/ Field Seam
![Page 14: Firestone Building Products EPDM Training – Base Tie-in and Roof Edge.](https://reader035.fdocuments.net/reader035/viewer/2022062519/5697c0041a28abf838cc410b/html5/thumbnails/14.jpg)
Details: Roof Edge w/ Field Seam
Missing T-Joint Cover
![Page 15: Firestone Building Products EPDM Training – Base Tie-in and Roof Edge.](https://reader035.fdocuments.net/reader035/viewer/2022062519/5697c0041a28abf838cc410b/html5/thumbnails/15.jpg)
Details: Roof Edge w/ Field Seam
Missing T-Joint Cover
![Page 16: Firestone Building Products EPDM Training – Base Tie-in and Roof Edge.](https://reader035.fdocuments.net/reader035/viewer/2022062519/5697c0041a28abf838cc410b/html5/thumbnails/16.jpg)
Details: Roof Edge Splice
![Page 17: Firestone Building Products EPDM Training – Base Tie-in and Roof Edge.](https://reader035.fdocuments.net/reader035/viewer/2022062519/5697c0041a28abf838cc410b/html5/thumbnails/17.jpg)
Details: Roof Edge Metal Splice
![Page 18: Firestone Building Products EPDM Training – Base Tie-in and Roof Edge.](https://reader035.fdocuments.net/reader035/viewer/2022062519/5697c0041a28abf838cc410b/html5/thumbnails/18.jpg)
Roof Edge Tips• Wood nailers must be installed to meet applicable building codes or 200lbs per linear foot minimum in any given direction. • Metal flanges must be fully supported by wood and terminated at least ½” from the edge of the wood. • Metal flanges covering the wood nailer must be fastened every 4” o.c.• Lap sealant is required on the entire upslop edge of the QuickSeam Flashing. • When stripping in the edge with 5” QuickSeam Flashing be sure to center the edge metal nails underneath the flashing.