FireClass Overview 2 - tfppemea.comtfppemea.com/en/_layouts/fsassets/Docs/Detection_FireClass... ·...
-
Upload
nguyendien -
Category
Documents
-
view
222 -
download
0
Transcript of FireClass Overview 2 - tfppemea.comtfppemea.com/en/_layouts/fsassets/Docs/Detection_FireClass... ·...
FireClass Overview 2
Tyco Heritage and Experience
• World leading fire and security company
• Over 50 years of technological expertise
• Driving innovative technology
• First triple sensing technology
• First with Carbon Monoxide technology
• Global network of engineers in 15 R&D facilities worldwide
• Creating solutions tailored to local markets and customer needs
• Sharing technology knowledge and ideas
Tyco R&D Centres of Excellence
FireClass Overview
• FireClass is a revolutionary new class of
commercial fire detection system
• Out-of-the-box, digital open-protocol
solution, that is easy to install
• FireClass is designed to appeal to both the
end user and installer
• Easy to install
• Part of Tyco International, the world leader
in fire and security solutions
• Tyco Heritage – specialising in control
equipment for the last 50 years
• Designed and engineered in Europe
What is FireClass?
3
FireClass Overview
• Open Protocol – Openly available
- Freedom of choice
• Out of the Box – complete solution • Easy to install and configure
• One provider - One stop shop solution
• Proven technology – over 50 year Heritage
• Extensive product range
• Comprehensive back-up and support
• Unrivalled Customer Service
• Approved to all Major European Standards
Benefits of FireClass
4
FireClass Overview 5
Who needs FireClass ?
• Who need to
know about
the latest
fire detection
technology to
specify including:
• Easy to design
• Flexible
• Open Protocol
• Covers a wide
range of risks
• Comprehensive
range
Engineers Consultants Installers
• Who want an
easy to
procure and
easy to install
system including:
• Complete fire
solution from
a single provider
• Open Protocol
• Products for
all risks and
applications
End - Users
• Who need a cost
effective, reliable,
False Alarm free
Fire Detection
System including:
• Open Protocol
• Easy and flexible
to maintain
• Meets regulations
• Minimal false alarms
• Flexible
• Future proof
FireClass Overview
FireClass product range gives the flexibility and versatility for most applications
Versatile and Flexible
6
Hotels Restaurants
Schools
Hospitals
Retail
Warehouse
Nursing homes
Offices
Special Hazards
FireClass Conventional Products
• Comprehensive range
• Low Cost 2 Zone to Multiple Zone applications
• 2 Wire variants available
• Fully approved to EN54 and CPD
• Easy to install
• Proven technology
• Full range of repeater options available
• Surface and Flush mounting variants
Conventional Range
8
General Features
FireClass Conventional Products
• 2,4 & 8 Zone versions
• Easy to install, program and use.
Key operated controls
• Panels can be surface or semi flush mounted
• 20mm cable gland breakouts
• Low standby power consumption.
• 4 Sounder circuits 4 & 8 zone, 2 on
2 zone panel. Zonal & Alert sounder
options configurable
Conventional Control Panel - Duo-Cel
9
• 1.5A switched mode power supply with
temperature compensated battery charging
• 8 Zone repeaters available with 24V or mains
operation (suitable for 4 & 8 zone panels only)
• Short circuit zone activation option (Global)
• End of Line zone resistor option
for retrofitting (Global)
General Features
FireClass Conventional Products
Conventional Control Panel - Precept EN
10
General Features
• From 2 to 32 zones
• EN54-2 / CPD approval (BSi)
• 4 alarm circuits as standard
(4 zone panel and above)
• Up to 5 fully-functional repeaters
- 2-wire RS485
• Extensive configurable facilities
for the engineer via DIL switches
• Zonal one-man test feature.
• Short Circuit to fire setting for use with older type detectors
• Panel inputs for class change, evacuate, silence alarms,
system reset
• 3 outputs for evacuate, buzzer active, disablement active
• Auxiliary supply output - monitored fuse
• Extensive expansions
• Optional timer clock/counter module
• Optional Foreign Language text inserts available
• Optional Semi-flush and fully flush mounting bezels available
FireClass Conventional Products
Gas Suppression Release - Prescient III
11
General Features
• 1st stage, 2nd stage, 3rd stage and gas
discharged outputs
• Single or double knock operation
• Pre-discharge delay adjustable from 0 to
60 seconds with visible countdown timer
• Discharged indication with or without pressure switch
• Option for rapid buzzer pulse when gas imminent
• One man zone and sounder test General Features
• From 2 to 32 zones
• EN54-2 / CPD approval (BSi)
• 4 alarm circuits as standard
(4 zone panel and above)
• Up to 5 fully-functional repeaters
- 2-wire RS485
• Extensive configurable facilities
for the engineer via DIL switches
• Zonal one-man test feature.
FireClass Conventional Products
Features SLU1 SLU2 SLU3
Two core data link between panel and status unit
Two core power connection between panel and status unit
Indication of events/status only unit
Manual Release
Auto/Manual Keyswitch
Countdown timer
Abort and hold off switch
Gas Suppression Release – Status Indicator Units
12
FireClass Conventional Products
• Extensive range for all applications and risks
• Low profile, discreet and unobtrusive
• Superior proven performance and reliability
• Designed for fast, easy installation
• Integral alarm LED
Conventional Detection
13
Model Type Description
601PH High Performance Optical Detector
Combined Smoke and Heat ideal for use with slow smouldering fires or open flaming fires.
601CH Enhanced Carbon Monoxide Detector
Provides very early warning for slow smouldering fires ideal for sleeping risks.
601P Optical Smoke Detector Ideal for use with slow burning or smouldering fires
601HR/F Heat Detector A fixed temp or rate of rise heat detector ideal for use where smoke detectors cannot be situated.
601F Infra Red Flame Detector Ideal for protecting large open areas without sacrificing speed of response to flaming fires
13
FireClass Conventional Products
• Extensive range
• Standard and Diode Bases options
• Sounder Base with Adjustable volume
• Designed for fast, easy installation
• Remote alarm LED
• Relay Base option
Conventional Detection Ancillaries
14
Model Type Description
4 B Conventional Detector Base Standard Conventional detector mounting base
4B-D Conventional Diode Base Standard Conventional Detector base with Diode.
601 SB Conventional Sounder Base Conventional Sounder base with adjustable volume.
601 SBD Conventional Sounder Base with Diode
Conventional Sounder base with Diode and Adjustable volume
MC 600 Relay Base Conventional relay base
CTA Ceiling Tile Adaptor Kit Easy fit adaptor for Ceiling tile mounting of Detectors
14 14
FireClass Conventional Products
• Surface or Flush mounting.
• Test Key for easier commissioning and maintenance
• Optional Transparent hinged cover
• Hazardous area models available
• IP67 model for external use
• 2 Wire version for use with Duo-Cel 2 wire
Conventional Sounders • Extensive range of Bells and electronic sounders
• High sound output at low current
• Adjustable volume variants available
• Easy to install – reduces installation cost
• Weatherproof variants for external use
Conventional Call points
15 15
General Features
General Features
• Digital addressable Open protocol
• 250 addresses per loop (Lite 125)
• Full EN 54 / CPD approvals.
• Easy to program
“Out of the box” simplicity
Quick Start guide.
• Fully networkable Panels
Programmable over the network.
• PC based Interactive Graphical
User Interface available.
• Extensive range of Detection
including Multi and Tri –Sensors
• Sensors approved in all
operating modes.
• Comprehensive range of Loop
Powered Sounders/Beacons.
• Full range of loop I/O modules
FireClass Addressable Range - Overview
17 17 FireClass Addressable Products
FireClass Addressable Products
• Digital Open protocol
• High resilience to electrical interference / earthing issues
• Supports wide variety of cables and installations
• Supports interrupts for priority devices eg. Callpoints
• 250 Addresses per loop ( Lite version -125)
• Full Sychronisation of loop sounders
• 500 mA loop current
• Max. 2 Km loop length
• Multiple modes of device operation
• Central processing of loop data incorporating Multiple
detection modes and Algorithms and Fuzzy logic.
• High immunity to electrical interference.
• Interrupt processing for fast response.
FireClass Digital Open Loop Protocol Features
18 18
Fireclass Lite - Single Loop Panel
19 FireClass Addressable Products 19
• Up to 125 addresses.
• Single loop non networkable
• 640 Character Display
• 32 Zone LED’s
• Integral 2.5A Power Supply unit.
• Out of the box “Quick Start” configuration
• Displays temperature, CO level and smoke
level at point in alarm
• 3000 event log
• Manual and Automatic walk test and
reporting functions
• Automatic battery test
• Detector service functions
General Features
General Features
Addressable – One Loop FireClass 32
20 FireClass Addressable Products 20
• Up to 250 addresses.
• Single Loop Networkable (up to 24 Panels)
• EN54 Part 2&4 and CPD approved.
• 640 Character Display
• 32 Zone LED’s
• Integral 2.5A Power supply unit
• Permanently display of system status
• Displays sensors temperature, CO level and smoke
level at point in alarm
• 3000 event log
• Manual and automatic walk test and reporting functions
• Detector service functions
• Extensive I/O Expansion options
General Features
Addressable Two – Four Loop FireClass 64
21
FireClass Addressable Products 21
• Up to 1000 addresses.
• Up to 250 addresses per loop
• Multi Loop Networkable (up to 24 Panels)
• EN54 Pt 2&4 and CPD approved
• 640 Character Display
• 64 Zone LED’s
• Integral 5A Power supply unit
• Displays sensors temperature, CO level and smoke
level at point in alarm
• 3000 event log
• Manual and automatic walk test and reporting functions
• Detector service functions
• Extensive I/O Expansion options
Addressable – Two or Four Loop FireClass 240
General Features
22
FireClass Addressable Products 22
• Up to 1000 addresses.
• Up to 250 addresses per loop
• Multi Loop Networkable (up to 24 Panels)
• EN54 Pt 2&4 and CPD approved
• 640 Character Display
• 240 Zone Non-LED
• Integral 5A Power supply unit
• Displays sensors temperature, CO level and
smoke level at point in alarm
• 3000 event log
• Manual and automatic walk test and reporting functions
• Detector service functions
• Extensive I/O Expansion options
FireClass Addressable Repeater Panels
23 FireClass Addressable Products 23
General Features
• 32, 64 and 240 Zone repeaters available
• Small compact enclosure
• Up to 7 repeaters per panel
• Integral 2.5A Power Supply
• AC and DC versions available
• Comprehensive Programming Software
• Simple and Intuitive
• Fast Panel set up
• Text / Device / Zone allocation
• Cause Effect Programming
• Import of project data
• Update Panel Firmware
• Export Date to FCG Graphics System
• Upload via Serial port and Programming lead
FireClass Express Software
24 FireClass Addressable Products 24
General Features
Network Platform
Networking Platform – Utilising the TLI800EN
25
General Features
• EN54 Approved
• Fault tolerant peer to peer networking
• Up to 24 Panel Network
• Up to 24,000 points maximum
• Programming can be achieved across the Network
• Allows connection to other networked panels
• Allows connection to FireClass Graphics System
• Supports Shielded twisted pair cabling
• EN54 and CPD approved
• Wide range including Multi and Tri Sensors
• FireClass HPO detection algorithms
• FireClass CO detection technology
• Up to 250 detectors per loop
• Extended service life
• Drift Compensation
• Fire, isolate and fault LED indications
• Standard base and isolator base available
Addressable Detectors FC460
26
A combined total of 22 approved modes and sensitivities to choose from
Model Type Description
FC 60PH High Performance Optical Detector
Combined Smoke and Heat ideal for detecting slow smouldering fires or open flaming fires.
FC460P Optical Smoke Detector Ideal for detecting slow burning or smouldering fires
FC460H Heat Detector A fixed temp or rate of rise heat detector ideal for use where smoke detectors cannot be situated.
F460PC Triple Sensing Detector Smoke, Heat and Carbon Monoxide
FireClass Addressable Products 26
• Loop powered - reduced installation costs
• High sound output characteristics
• Low current consumption
• Synchronisation of Sound output
• Clean lines, modern styling
• Easy to install, low installation costs
• Multiple tones and flash rate to suit individual requirements
• Integral line isolator
Addressable Sounders / Beacon Bases
27
Model Type Description
FC430LPSB Addressable Sounder Base Loop powered Addressable Sounder base with integrated base and Loop Isolator
FC430LPASB Addressable Sounder / Beacon Base
Loop powered Addressable Sounder Beacon base with integral base and Loop Isolator.
FireClass Addressable Products 27
• Loop powered - reduced installation costs
• High sound output characteristics
• Low current consumption
• Synchronisation of sound output
• Easy to install, low installation costs
• Weather proof units for outdoor use
• Multiple tones and flash rate to suit individual requirements
• Integral line isolator
Addressable Sounders
28
Model Type Description
FC410LPSY(R/W) Loop powered Sounder Addressable Loop Powered Sounder Red (R) White (W)
FC410LPSY Weatherproof Loop Powered Sounder
IP65 Addressable loop Powered Sounder Red
FC410LPAVR Loop powered Sounder / beacon
Addressable Loop Powered Sounder Beacon Red
FC410LPAV Weatherproof Loop Powered Sounder Beacon
IP65 Addressable Loop Powered Sounder Beacon Red
FireClass Addressable Products 28
• Integral LED indicator for easy identification of operation
• Surface or Flush Mounting
• Test key facility, speeds maintenance visits
• Optional transparent hinged cover
• IP67 Waterproof models for external applications
Addressable Call Points
29
Model Type Description
FC420CP Indoor Call Point Manual Call Point – Internal use
FC421CP Outdoor Call Point Manual Call Point IP 67 – External Use
FireClass Addressable Products 29
• Loop Powered.
• Built in loop isolator.
• Standard Housing
• Detachable connectors
Addressable Quad Modules
30
Model Type Description
FC410QMO Quad Output Module 4 x monitored Outputs that can be configured for spur or loop wiring
FC410QIO Quad I/O Module 4 x Monitored Inputs and 4x Volt free relay outputs
FC410QRM Quad Relay Module 4 x Volt free relay outputs – supply to relays can be monitored
FireClass Addressable Products 30
• Wide range.
• Comprehensive input / Output functions.
• Loop Powered where applicable.
• Easy connection terminals.
• Compact enclosures.
• LED indication.
Addressable Ancillary Modules
31
Model Type Description
FC410LI Line Isolator Module Short Circuit Isolator
F410MIM Mini Input Module Single Input – from N/O or N/C contacts
FC410CIM Contact Input module 2 Inputs – From N/O or N/C contacts
FC410DIM Detector Input Module Zone Input – supports 1 Zone of Conventional Detectors
FC410SIO Single Input / Output Module 1 Input and 1 Output
FC410MIO Multiple Input / Output Module 3 Inputs and 2 Outputs
FC410BDM Beam Detector module Connects Fireray 5000 to loop
FireClass Addressable Products 31
• Fast and accurate Address programming of Detectors
• Fast and accurate programming of ancillary devices
such as Loop Powered Sounders and Interface
modules
• Verification of Detector operation and condition
• convenient backlight
• Complete with charger, batteries & programming lead
for sounders / interfaces
• Undongled - no password or expiry
Loop Service Programmer FC490ST
FireClass Addressable Products 32
General Features
• Graphical Interface with addressable
control panels and Network
• High resolution detailed map of site
linked to floor plans
• Intuitive multi layered mapping
• Interactive Control of Panels / System
• Extensive event logging and Alarm
management tools.
FireClass Graphics
33 FireClass Addressable Products 33
General Features