Fire Rated I-Joists

4
WEBSHIELD PROTECTED I-JOIST GUIDE FRI 20, FRI 23, FRI 35+, FRI 40, FRI 50 USA Fire Rated I-Joists for Unfinished Basements TM

Transcript of Fire Rated I-Joists

Page 1: Fire Rated I-Joists

WEBSHIELD PROTECTED I-JOIST GUIDE FRI 20, FRI 23, FRI 35+, FRI 40, FRI 50 USA

Fire Rated I-Joistsfor Unfinished Basements

TM

Page 2: Fire Rated I-Joists

Member of

WHY ARE BUILDERS DEMANDING WEBSHIELD PROTECTED FRI JOISTS IN THEIR HOUSES?1. Meets 2012 IRC 501.3 exception 4 and 2015 IRC 302.13 Code Requirements.2. FRI WebSHIELD protection, applied to standard PKI joists, provides superior fire performance when

compared to other products.3. Pinkwood Ltd. produces a wide range of FRI WebSHIELD protected I-Joist series and depths 11-7/8” to

16” to satisfy all builder requirements.4. Framers prefer working with FRI Joists for ease of handling, wide-flange nailing, and side nailing capabilities.5. By utilizing standard PKI joists, mechanical, electrical and plumbing penetrations are made with ease.6. Home owners enjoy Pinkwood’s FRI WebSHIELD protected joists for the peace of mind offered by the

added fire protection.7. Pinkwood contributes a portion of all WebSHIELD sales to breast cancer research.

PKI becomes FRI SERIESFRI Joists series are manufactured utilizing standard PKI joists with either 2x3” (PKI 20, 23 or 2x4” (PKI 35+, 40, 50 flanges which have a specific proprietary lumber grade. Having only two flange sizes results in simplified selection of hangers and fasteners and thereby reduces the number of component SKU’s required by the dealer.

Features Benefits

Wide Nailing Easy diaphragm nailing

Side Nailing No structural issues regarding bridging elements, sprinkler attachments, pot lights etc

End Nailing Rim attachment at sill plate, three nails in close proximity can cause issues with LVL flange

Fire Rated Code Approved: Meets 2012 IRC Section R501.3 exception 4 and 2015 IRC Section 302.13

Holmes Approved Mike Holmes actively promoting protected EWP

Socially Responsible Supporting breast cancer research

FRI 23 SERIESDepth: 11-7/8" thru 16"Flange: 2-1/2" x 1-1/2"Web: 7/16" OSB

FRI 35+ SERIESDepth: 11-7/8" thru 16"Flange: 3-1/2" x 1-1/2"Web: 3/8" OSB

FRI 40 SERIESDepth: 11-7/8" thru 16" Flange: 3-1/2" x 1-1/2" Web: 3/8" OSB

FRI 50 SERIESDepth: 11-7/8" thru 16" Flange: 3-1/2" x 1-1/2" Web: 7/16" OSB

FRI 20 SERIESDepth: 11-7/8" thru 14"Flange: 2-1/2" x 1-1/2"Web: 3/8" OSB

Standard PKI Joists Readily available PKI Joists become FRI Fire Rated with the addition of the WebSHIELD

Wide range of FRI Joists With 5 series and 7 depths any floor system can be optimized for cost

Easy Hole Cutting Unprotected joists sections can be cut as standard i-joists

TM

Page 3: Fire Rated I-Joists

WebSHIELD FRI

Joist Type

Simple/Multiple Spans (ft-in)

O/C SPACING

12” 16” 19.2” 24”

11 7/8”

FRI 20 22’- 0” 19’- 8” 18’- 0” 16' - 1”

FRI 23 22’- 5” 20’- 1” 18’- 4” 16’- 6”

FRI 35Plus 23’- 3” 20’- 9” 19’- 0” 17’- 3”

FRI 40 25’- 7” 23’- 4” 22’- 1” 20’- 7”

FRI 50 25’- 8” 23’- 5” 22’- 3” 20’- 8”

14”

FRI 20 24’- 5” 21’- 3” 19’- 5” 17- 5”

FRI 23 25’- 0” 21’- 9” 20’- 0” 18’- 9”

FRI 35Plus 25’- 10” 22’- 6” 20’- 8” 19’- 1”

FRI 40 28’- 11” 26’- 5” 24’- 11” 23’- 3”

FRI 50 29’- 1” 26’- 7” 25’- 0” 23’- 5”

16”

FRI 20 26’- 2” 22’- 9” 20’- 9” 18’- 8”

FRI 23 26’- 8” 23’- 4” 22’- 1” 20’- 7”

FRI 35Plus 27’- 8” 24’- 2” 22’- 9” 19’- 4”

FRI 40 31’- 11” 29’- 2” 27’- 6” 25’- 7”

FRI 50 32’- 1” 29’- 4” 27’- 8” 25’- 9”

40 PSF LL/ 10 PSF DL (L/480) - 23/32” SHEATHING GLUED & NAILED

a. Allowable design span applicable to simple and multiple-span residential floor construction with loads as indicated in the above table. The live load deflection is limited to span/480. Verify span capacities in accordance with latest version of CSD software.

b. Spans are based on a composite floor with glued-nailed sheathing meeting the requirements for APA Rated Sheathing or APA Rated STURD-I-FLOOR conforming to PS 1, PS 2, CSA O325, or CSA O437. Adhesive shall meet ASTM D3498 or APA Specification AFG-01.

c. Minimum end bearing length shall be 1-1/2 inches for 11-7/8” to 16” deep I-joists.

d. When WebSHIELD panels fall directly over bearing, web stiffeners may be omitted when WebSHIELD length is a minimum of 3-1/2".

e. Bearing stiffeners are not required for end bearings when I-joists are used with the spans and spacings given in this table, except as required by hanger manufacturers.

f. For multiple spans, underlined spans require 3-1/2” intermediate bearing with web stiffener, all other span require 3-1/2” intermediate bearing without web stiffener.

NOTES:PKI SERIESJoist Depth

Joist Depth

Series SAF

Minimum Distance from Inside Face of Any Supports to Center of Hole (ft-in)

Round Hole Diameter (in.)

4 5 6 6 1/2 7 8 8 3/8 9 10 10 1/2 11 12

11 7/8”

PKI20 16.32 1’-5” 2’-8” 3’-11” 4’-3” 5’-2” 6’-8” 7’-11”

PKI23 17.52 1’-2” 2’-6” 3’-10” 4’-3” 5’-4” 6’-10” 8’-2”

PKI35Plus 17.67 2’-4” 3’-7” 4’-10” 5’-2” 6’-2” 7’-9” 9’-1”

PKI40 19.96 4’-1” 5’-6” 6’-11” 7’-3” 8’-5” 10’-1” 11’-2”

PKI50 20.08 1’-2” 2’-7” 4’-5” 4’-10” 6’-3” 8’-2” 9’-6”

14”

PKI20 17.69 1’-2” 1’-5” 2’-7” 2’-10” 3’-9” 5’-0” 5’-10” 6’-4” 7’-10” 9’-8”

PKI23 19.24 1’-2” 1’-3” 2’-2” 2’-6” 3’-6” 4’-11” 5’-10” 6’-4” 8’-0” 9’-9”

PKI35Plus 18.42 1’-3” 2’-5” 3’-7” 3’-10” 4’-9” 6’-1” 6’-11” 7’-6” 9’-4” 11’-5”

PKI40 22.63 3’-5” 4’-9” 6’-1” 6’-5” 7’-6” 8’-11” 9’-11” 10’-6” 12’-2” 13’-7”

PKI50 22.76 1’-2” 2’-4” 3’-11” 4’-4” 5’-6” 7’-3” 8’-4” 9’-0” 10’-11” 12’-5”

16”

PKI20 18.97 1’-2” 1’-3” 1’-5” 1’-8” 2’-6” 3’-8” 4’-5” 4’-10” 6’-1” 7’-1” 7’-5” 9’-3”

PKI23 19.90 1’-2” 1’-3” 1’-3” 1’-4” 1’-5” 2’-9” 3’-7” 4’-1” 5’-8” 7’-0” 7’-5” 9’-5”

PKI35Plus 18.71 1’-2” 1’-5” 2’-6” 2’-10” 3’-8” 4’-10” 5’-7” 6’-1” 7’-4” 8’-4” 8’-9” 11’-0”

PKI40 25.03 2’-3” 3’-7” 4’-10” 5’-2” 6’-2” 7’-6” 8’-5” 9’-0” 10’-6” 11’-9” 12’-2” 14’-3”

PKI50 25.17 1’-2” 2’-2” 3’-7” 3’-11” 5’-1” 6’-7” 7’-7” 8’-2” 9’-10” 11’-1” 11’-7” 13’-5”

ALLOWABLE HOLE LOCATION IN NON-WEBSHIELD SECTIONS

Page 4: Fire Rated I-Joists

A product of PinkWood Ltd. Visit us at www.PinkWood.ca5929, 6th Street NE Calgary, Alberta, Canada T2K 5R5

Pinkwood’s PKI I-Joists are available in CSD, the leading third party software suite that makes it seamless for engineers and design professionals to offer their clients the benefits of the PKI product line with minimal effort and maximum flexibility.

WebSHIELD v1.0 - 2016

DESIGN SOFTWARE

ENGINEERED FLOOR SYSTEM GUARANTEE

PinkWood joists are manufactured to meet or exceed the rigorous engineering and testing standards set by every major code approval agency in North America.

All PinkWood joist products are unconditionally guaranteed to be free of manufacturing defects. PinkWood Ltd. guarantees that its PinkWood joist products, when installed and handled as per the PKjoist installation guide, will perform in accordance with the published structural specifications.In the unlikely event that a problem occurs due to a manufacturing defect, PinkWood Ltd. shall be given a reasonable opportunity to inspect the PinkWood product on site. If this evaluation reveals a problem due to manufacturing defects, the situation shall be promptly corrected.Please feel free to contact a representative of PinkWood Ltd. for specific d etails and limitations of this guarantee.

CODE COMPLIANT

All Pinkwood FRI WebSHIELD series products have been reviewed and evaluated for code compliance and meet the minimum requirements outlined in the 2012 and 2015 IRC (International Residential Code) for use in exposed unfinished basements. See UES-0431