Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of...

45
Fire in Timber Structures Roberto Tomasi 11.05.2017 Roberto Tomasi Fire in Timber Structures 11.05.2017 1 / 45

Transcript of Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of...

Page 1: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

Fire in Timber Structures

Roberto Tomasi

11.05.2017

Roberto Tomasi Fire in Timber Structures 11.05.2017 1 / 45

Page 2: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

Overview

1 Introduction and fire safety

2 Timber Fire Behaviour

3 Timber fire design standard methods

Roberto Tomasi Fire in Timber Structures 11.05.2017 2 / 45

Page 3: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

The Great Fear of Fire

Myths and fallacies of timber engineeringSmall pieces of wood burn well...

Roberto Tomasi Fire in Timber Structures 11.05.2017 3 / 45

Page 4: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

The Great Fear of Fire

Myths and fallacies of timber engineering. . . but a timber structure with an appropriate design can offer equal ormore fire resistance than the usual structures made with steel or concrete.

Roberto Tomasi Fire in Timber Structures 11.05.2017 4 / 45

Page 5: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

References

Roberto Tomasi Fire in Timber Structures 11.05.2017 5 / 45

Page 6: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

Introduction and fire safety

Process of Fire Development

Combustion Reaction

Flashover is the transition in the burning period, it can be estimatedhaving T ∼= 400÷ 600◦ C

Roberto Tomasi Fire in Timber Structures 11.05.2017 6 / 45

Page 7: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

Introduction and fire safety

Design Concepts of Fire Prevention

There must be a number of active and passive provisions against fire.

Active Provisions refer to control of fire through actions taken by personsor by automatic devices, e.g.: automatic detection,emergency exit, active control of smoke (by fans or otherdevices), fire extinguishers, automatic sprinkler systems, firealarm, firefighters etc.

The structural performance of a structure vs Fire is defined in terms ofTIME, e.g. R60 means that the resistance is guaranteed until 60 minutes.

Roberto Tomasi Fire in Timber Structures 11.05.2017 7 / 45

Page 8: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

Introduction and fire safety

Design Concepts of Fire Prevention

There must be a number of active and passive provisions against fire.

Passive Provisions refer to control by systems built into the structure,not requiring any operation by people or by automaticcontrols e.g. selection of materials, fire resistance ofstructures, containment of fire (preventing fire spread), partywalls, compartment

The structural performance of a structure vs Fire is defined in terms ofTIME, e.g. R60 means that the resistance is guaranteed until 60 minutes.

Roberto Tomasi Fire in Timber Structures 11.05.2017 8 / 45

Page 9: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

Introduction and fire safety

Design Concepts of Fire Prevention

Simplifying, passiveprovisions follow astructural approach,active provisions arebased on fireMonitoring and all fireextinguisher systems.

Roberto Tomasi Fire in Timber Structures 11.05.2017 9 / 45

Page 10: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

Introduction and fire safety

Fire safety and current regulations

Fire safety involves prevention, detection, evacuation, containment, andextinguishment.

Fire prevention basically means preventing the sustained ignition ofcombustible materials by controlling either the source of heat or thecombustible materials.

Two main categories can be:material requirements include such things as combustibility, flame

spread, and fire resistance.building requirements include area and height limitations, firestops and

draftstops, doors and other exits, automatic sprinklers, firedetectors.

Code officials should be consulted early in the design of a building becausethe codes offer alternatives.Adherence to codes will result in improved fire safety (?)

Roberto Tomasi Fire in Timber Structures 11.05.2017 10 / 45

Page 11: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

Introduction and fire safety

Fire safety and current regulations

Construction Products Regulation (305/2011/EU - CPR)Subject to normal maintenance, construction works must satisfy these basicrequirements for construction works for an economically reasonable working life.

The Construction Products Regulation (EU) No 305/2011 (CPR), which repeals theConstruction Products Directive (EU) No 89/106/EEC, was adopted on 9 March 2011.Its validity started July 2013.

Fundamental difference between CPR 305/2011 and CPD 89/106/EEC

The Declaration of Performance (DoP) is the key concept in the Construction ProductsRegulation (CPR).

The DoP gives the manufacturer the opportunity to deliver the information about theessential characteristics of his product he wants to deliver to the market. Themanufacturer shall draw up a Declaration of Performance when a product covered by aharmonised standard (hEN) or a European Technical Assessment (ETA) is placed on themarket.

The manufacturer, by drawing up his DoP, assumes the responsibility for the conformityof the construction product with the declared performance.

Roberto Tomasi Fire in Timber Structures 11.05.2017 11 / 45

Page 12: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

Introduction and fire safety

Fire safety and current regulations

Role and Importance of a Standard FireThe standard temperature-time curve for direct testing in furnace given inEN 1363-1 is the so-called ISO 834 curve: Tt = 345 log(8t + 1) + 20

EN 1363-2 specifies alternativeheating conditions, to be usedunder special circumstances.As said, Standard Fire allowsto:

• determine Fire resistance

• determine MaterialCharacteristics as afunction of Temperature(for concrete, masonry,steel . . . )

. . . on a Standardized basis!

Roberto Tomasi Fire in Timber Structures 11.05.2017 12 / 45

Page 13: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

Introduction and fire safety

Fire safety and current regulations

Terms and Definitions

Reaction to fire refers to material behaviour, the product shall beclassified on the basis of its reaction-to-fire performance,including such things as combustibility, flame spread etc.,having regard to the classification system based on class ofreaction-to-fire

Fire resistance refers to structure behaviour, the load-bearing functionmust be maintained during the required time of fire exposure,therefore it is specified in terms of minutes

Roberto Tomasi Fire in Timber Structures 11.05.2017 13 / 45

Page 14: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

Introduction and fire safety

Fire safety and current regulations

Terms and Definitions

The classification of performance of building elements is achieved withcodes:

R-EI-REI (labels) + 30-60-90-... (Resistance in minutes)

ex. R30; EI90; REI60

Label Definition

R Load Bearing: ability to sustain the applied load at some pointduring fire

E Integrity: ability to stop the passage of flame or hot gasesI Insulation: ability to restrict the temperature rise of the

unexposed face of the element to below specified levels.

Roberto Tomasi Fire in Timber Structures 11.05.2017 14 / 45

Page 15: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

Introduction and fire safety

Fire safety and current regulations

Terms and Definitions

Label Definition Fire surfaces 1D Elements 2D Elements

R Load bearing elements,without "compartment"function

1, 2, 3

EI Non-Load bea-ring elements, with"compartment" function

1 -

REI Load bearing elements,with "compartment"function

1 -

Roberto Tomasi Fire in Timber Structures 11.05.2017 15 / 45

Page 16: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

Timber Fire Behaviour

Thermal degradation of wood

Complete combustion requires adequate oxygen and the 3 T’s:Time, Temperature, Turbulence

Roberto Tomasi Fire in Timber Structures 11.05.2017 16 / 45

Page 17: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

Timber Fire Behaviour

Thermal degradation of wood

Sequence of combustion phenomenaScheme of the temperature sequence of the involved phenomena.

Temperature Phenomena

20 ◦C Sample temperature before ignition100 ◦C Water Loss120 ◦C Decay begins (lignin plasticization)170 ◦C Pyrolysis begins

Over 170 ◦C Pyrolysis products combustion

300 ◦C EC5 Isotherm of not returning point

Eurocode 5 fixes another not return point, where it places the charringtheoretical line on the 300 ◦C isotherm inside the wood mass: from thisline the strength and modulus of wood must be taken as zero value.

Roberto Tomasi Fire in Timber Structures 11.05.2017 17 / 45

Page 18: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

Timber Fire Behaviour

Thermal degradation of wood

Aspects of thermal decay

Phenomena involved in the charring processmodified from Dinwoodie, (1981),

Timber, its nature and behaviour, E and FN SPON,London

The combustion (and thermaldemolition) of wood proceeds fromits exposed outer surface towards theinside of its mass with adetermined finite rate, so theprocess is not instantaneous. Thisvelocity depends mainly on thewood species, while, amongenvironmental factors,temperature, heat contributionand ventilation are determining.Among the material conditions, themost significant ones are moisturecontent and treatments that thematerial may have undergone.

Roberto Tomasi Fire in Timber Structures 11.05.2017 18 / 45

Page 19: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

Timber Fire Behaviour

Thermal degradation of wood

Aspects of thermal decay

Phenomena involved in the charring processmodified from Dinwoodie, (1981),

Timber, its nature and behaviour, E and FN SPON,London

It can therefore be said that, in a fire,the depth of destroyed material isapprox. proportional to theexposure time (more exactly, to theduration of the charring process).Another important point to beremarked is that “normal wood”exhibits temperatures below 100 ◦C,except for a small layer (10÷20mm)next to the pyrolysis zone. Charringrate ∼ 0,6 ÷ 0,7 mm/min

Roberto Tomasi Fire in Timber Structures 11.05.2017 19 / 45

Page 20: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

Timber Fire Behaviour

Thermal degradation of wood

Roberto Tomasi Fire in Timber Structures 11.05.2017 20 / 45

Page 21: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

Timber Fire Behaviour

Timber vs. other construction materials

Why choose a combustible material, such as timber/glulam/CLT,for structural elements that must ensure a given level of fireresistance?Let us observe the gradual change (evolution) of the mechanical properties of somebuilding materials when exposed to a standard fire. The parameters are measured withreference to the performance of physically defined elements.For all materials but wood, the test piece size and shape do not have a significanteffect: for these materials, moreover at any time a temperature constant over the wholesection can be hypothesized, slightly lower than the environment temperature, and it istherefore correct to think that all material properties vary accordingly.In wood instead, under the charred layer, there is no significant temperature increaseand the material properties consequently remain unchanged.Wood seems therefore to feature a better pattern, but what is being observed is not thetemperature induced evolution of the material properties, but the evolution ofperformances for an element with a given (here 50 mm x 50 mm) initial cross section,that is the decrease of the resisting section during the exposure to fire. The advantage,when utilising wood, does not lie in the variation of its mechanical parameters withtemperature, but in the slow and somehow predictable mass thermal evolution.

Roberto Tomasi Fire in Timber Structures 11.05.2017 21 / 45

Page 22: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

Timber Fire Behaviour

Timber vs. other construction materials

Evolution of the mechanical properties of some building materials whenexposed to a standard fire

Roberto Tomasi Fire in Timber Structures 11.05.2017 22 / 45

Page 23: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

Timber Fire Behaviour

Thermal degradation of wood

Evolution of the mechanical properties vs temperature of wood and steel

WoodSteel

Roberto Tomasi Fire in Timber Structures 11.05.2017 23 / 45

Page 24: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

Timber Fire Behaviour

Thermal degradation of wood

Evolution of the mechanical properties vs temperature of wood and steel

Wood Steel

Roberto Tomasi Fire in Timber Structures 11.05.2017 24 / 45

Page 25: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

Timber fire design standard methods

Frame Safety Requirements

Design of Fire Resistance

1 Requirement ⇒ Definition of Rd (REI) in terms of time T (see EN1991-1-2)

REI 15 20 30 45 60 90 120 180 240 360

2 Check of fire resistance ⇒ Check t ≥ treq (see EN 1995-1-2)

Concerning the Requirement it is necessary to refer to:• fire load density (defined hereinafter), either based on measurementsor based on fire resistance requirements given in National regulations

• specific National Regulations regarding occupancies (e.g. offices,hotel, residence, manufactories . . . )

Roberto Tomasi Fire in Timber Structures 11.05.2017 25 / 45

Page 26: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

Timber fire design standard methods

Fire Safety Requirements

RequirementsThe fire load density qf ,d used in calculations should be a design value,either based on measurements or in special cases based on fire resistancerequirements given in national regulations.The design value may be determined• from a national fire load classification of occupancies• specific for individual project by performing a fire load survey

qf ,d = δq1 · δq2 · δn · qf ,k [MJ/m2] Fire Load Density

qf ,k [MJ/m2] characteristic fire load density per unit floor areaδq1 [1÷ 2] depending on the risk due to the size of compartmentδq2 [0, 8÷ 1, 2] depending on the risk due to the type of

occupancyδn =

∏i=1÷10 δni depending on the different fire fighting measures,

with δni = [0, 6÷ 0, 9]

Roberto Tomasi Fire in Timber Structures 11.05.2017 26 / 45

Page 27: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

Timber fire design standard methods

Fire Safety Requirements

RequirementsEN 1991-1-2: different values can be found in the national annex of singleEU countries.

Factor δq1

Compartment floor area [m2] Value25 1,10250 1,502500 1,905000 2,00≥10000 2,13

Factor δq2

Ex. of occupancies ValueArtgallery, museum,

swimming pool 0,78Offices, hotel, residence 1,00Manufactory for engines

and machinery 1,22Chemical lab, painting

workshop 1,44Manufactory of fireworks

or paints 1,66

Roberto Tomasi Fire in Timber Structures 11.05.2017 27 / 45

Page 28: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

Timber fire design standard methods

Fire Safety Requirements

Requirements

δn =∏

i=1÷10

δni

Roberto Tomasi Fire in Timber Structures 11.05.2017 28 / 45

Page 29: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

Timber fire design standard methods

Fire Safety Requirements

RequirementsThe fire load can be determined either• from a fire load classification of occupancies (given by classification orcalculated for the building

• specific for individual projectThe characteristic fire load density is defined as:

Qfi ,k =∑

Mk,i · Hu,i ·Ψi =∑

Qfi ,k,i [MJ] qf ,k = Qfi ,k/A [MJ/m2]

Mk,i [kg ] amount of i-th combustible materialHu,i [MJ7kg ] net calorific value of i-th combustible material

Ψi optional factor, to take into account "protected" combustiblematerials (usually Ψi =1)

A [m2] floor area of the fire compartment

Roberto Tomasi Fire in Timber Structures 11.05.2017 29 / 45

Page 30: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

Timber fire design standard methods

Fire Safety Requirements

RequirementsExamples of standard fire load densities qf ,k [MJ/m2] for differentoccupancies.Values valid for δq,2 = 1, 0Fire loads "from the building" should be added if relevant.

Occupancy Average value 80% fractile

Dwelling 780 948Hospital (room) 230 280Hotel (room) 310 377Library 1500 1824Office 420 511Classroom of a school 285 347Shopping centre 600 730Theatre (cinema) 300 365Transport (public space) 100 122

Roberto Tomasi Fire in Timber Structures 11.05.2017 30 / 45

Page 31: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

Timber fire design standard methods

Fire Safety of Timber Structures and Standards

It is especially interesting to study a wooden structure, undergoing a fire,analysing parts of the structure, imposing the accidental action of fire andverifying that for each of them the following condition is satisfied:

Ad ,fi (t) ≤ Rd ,fi (t)

where Ad ,fi is the design value of the effect of action under fire conditions,Rd ,fi the corresponding design resistance under the same conditions, and tthe duration of fire exposure.

Roberto Tomasi Fire in Timber Structures 11.05.2017 31 / 45

Page 32: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

Timber fire design standard methods

Fire Safety of Timber Structures and Standards

For the effects of the direct actions acting on the structure, thecombination rule for the so-called exceptional combinations is adopted,that can be written as follows:

Gk + Ψ1,1 · Qk,1 +∑

i

Ψ2,1 · Qk,i

Gk characteristic value of permanent actions;Qk,1 characteristic value of variable (principal) action;Qk,i characteristic values of other variable actions;Ψ1,1 combination coefficient for the variable action assumed as

principal;Ψ2,i generic combination coefficient for other variable actions.

The values for the combination coefficients Ψ are given as functions of the differentcategories of use for the different areas in buildings (EN 1991-1-1), and usually rangebetween 0 and 0,7. Caution should be used in those cases in which the maximum actioncan be foreseen during the fire event (e.g. libraries, archives and stores).

Roberto Tomasi Fire in Timber Structures 11.05.2017 32 / 45

Page 33: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

Timber fire design standard methods

Fire Safety of Timber Structures and Standards

A simplified method to calculate Ad ,fi when conditions are unchangedduring the fire is available. Starting from the fundamental combination ofactions Ad for normal temperature design, the values Ad ,fi can becalculated using the following equation:

Ad ,fi = ηfi · Ad

ηfi depends on the different safety factors γG and γQ (characteristicpermanent and variable actions), as well as on the combination factor Ψfi

for frequent values of variable actions in the fire situation, given either byΨ1,1 or Ψ2,1 (EN 1991-1-2), and it can be written as:

ηfi =Gk + Ψfi · Qk,1

γG · Gk + γQ,1 · Qk,1=

1 + Ψfi · ξγG + γQ,1 · ξ

ξ is the ratio Qk,1/Gk

Roberto Tomasi Fire in Timber Structures 11.05.2017 33 / 45

Page 34: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

Timber fire design standard methods

Fire Safety of Timber Structures and Standards

Values for ηfi as a function of permanent/variable actions ratio ξ

Diagrams ηfi as a function of ratio ξ and for different values of the combination coefficient Ψ1,1,assuming γG = 1, 35, γQ = 1, 5. Values 0,9, 0,7 and 0,5 correspond to category E (areassusceptible to accumulation of goods), C/D (meeting and shopping areas), A/B (areas fordomestic and residential activities, and office areas). High values of the ratio are usuallyfeatured by the so called "lightweight” structures, such as the wooden ones.

Roberto Tomasi Fire in Timber Structures 11.05.2017 34 / 45

Page 35: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

Timber fire design standard methods

Fire Safety of Timber Structures and Standards

The European Standard approach

Residual and effective cross section methods,

definition (EN 1995-1-2)

Thermal decay of wood as previouslydescribed justifies a standardised approachthat, however simplified, allows satisfactorydesign evaluations and verifications. Thefollowing terms will then be utilised:

• char line: transition area betweencharred layer and the residual crosssection;

• residual cross section: initial crosssection minus the thickness of thecharred layer;

• effective cross section: initial crosssection minus the thickness of thecharred layer and that of aunder-laying layer whose strength andstiffness are assumed to be zero.

Roberto Tomasi Fire in Timber Structures 11.05.2017 35 / 45

Page 36: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

Timber fire design standard methods

Fire Safety of Timber Structures and Standards

The European Standard approach

Residual and effective cross section methods,

definition (EN 1995-1-2)

In EN 1995-1-2, three different designapproaches with increasing complexity areenvisaged:

• effective cross section method;

• reduced properties method(reducedstrength and modulus) method;

• advanced calculation methods, withreference to charring models,temperature profile and moisturegradient over the cross section and towood strength and modulus variationswith temperature and moisture.

The first method entails both simplicity ofanalysis and consistency with the physicaldevelopment of the phenomenon.

Roberto Tomasi Fire in Timber Structures 11.05.2017 36 / 45

Page 37: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

Timber fire design standard methods

Fire Safety of Timber Structures and Standards

Effective cross section method

Residual and effective cross section methods,

definition (EN 1995-1-2)

In this method, an effective cross section iscalculated by subtracting from the initialcross section the thickness of an effectivecharring depth def given by:

def = dchar,n + k0 · β0

dchar,n = βn · t is the notional charring depth,βn is the notional charring rate,including the negative effects ofshakes and corner rounding

k0 is a coefficient ranging between 0 and1 (to be defined further on)

β0 = 7mm, is highest difference betweenresidual and effective cross section

Roberto Tomasi Fire in Timber Structures 11.05.2017 37 / 45

Page 38: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

Timber fire design standard methods

Fire Safety of Timber Structures and Standards

β0 and βn values for wood and wood based materials (EN 1995-1-2)

Roberto Tomasi Fire in Timber Structures 11.05.2017 38 / 45

Page 39: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

Timber fire design standard methods

Fire Safety of Timber Structures and Standards

Effective cross section method

Corner induced cross section

reduction (EN 1995-1-2)

If the corner rounding effect caused by simultaneousfire exposure on concurrent faces, the charring rateβ0 can be used. For a one-dimensional situation (e.g. a glued laminated beam), the charring depth canbe calculated referring to a 0 charring rate, close tothe results of (1-D) physical tests:

dchar,n = βn · tThe rounding radius of the corner must be assumedto be equal to the charring depth dchar,0. This isallowed as long as the minimum cross sectiondimension has a value greater than bmin, which isobtained from:

bmin =

{2 · dchar,0 + 80 if dchar,0 ≥ 13mm8, 15 · dchar,0 if dchar,0 < 13mm

If the minimum cross section dimension is orbecomes smaller than bmin, the βn values applyinstead.

Roberto Tomasi Fire in Timber Structures 11.05.2017 39 / 45

Page 40: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

Timber fire design standard methods

Fire Safety of Timber Structures and Standards

Effective cross section methodWhat is the difference taking into account or not the corner roundingeffect? The difference can be significant considering the final (reduced)cross-section, as shown in this simple example, in terms of section moduli.

Roberto Tomasi Fire in Timber Structures 11.05.2017 40 / 45

Page 41: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

Timber fire design standard methods

Fire Safety of Timber Structures and Standards

CLT ProductsGlued laminated and sawn timber (softwood and hardwood) are reported inEN 1995-1-2, but up to now CLT is not regulated within the EuropeanStandards!Is it possible to think that, if the base-material (i.e. boards) is thesame for assembling GLT and CLT, also the charring rate will bethe same?If the charring is beneath the first glue line, there is no problem (± until 30minutes), the answer is YES! If the process goes on, influencing the2nd layer, the charring rate for CLT is usually greater than for GLT.The problem is complicated by the glue usually employed by CLT producers! ThePUR-bond glue has thermal characteristics different from the ones used for GLT, as anexample the MUF glue.There are ETAs (European Technical Approval)of some producers that seem to confirm thisassumption.

Roberto Tomasi Fire in Timber Structures 11.05.2017 41 / 45

Page 42: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

Timber fire design standard methods

Fire Safety of Timber Structures and Standards

The European Standard approach: Strength and Modulus ofmaterialWhat are the values to be assumed for mechanical parameters during fire?

Roberto Tomasi Fire in Timber Structures 11.05.2017 42 / 45

Page 43: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

Timber fire design standard methods

Fire Safety of Timber Structures and Standards

Designing a fire resistant structureDesigning the protection

Wood is a fuel but it canbe protected

Wood burns with a constantcharring rate ∼ 0,7 mm/min

Timber section remainsunchanged if the protection isdesigned accordingly

Roberto Tomasi Fire in Timber Structures 11.05.2017 43 / 45

Page 44: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

Timber fire design standard methods

Fire Safety of Timber Structures and Standards

Designing a fire resistant structureDesigning the protection

Wood is a fuel but it canbe protected

Wood burns with a constantcharring rate ∼ 0,7 mm/min

Timber section is reduced,and its load carrying capacity(ULS) must be checked

Roberto Tomasi Fire in Timber Structures 11.05.2017 44 / 45

Page 45: Fire in Timber Structures - LTH · 2017-05-08 · Timberfiredesignstandardmethods Fire Safety of Timber Structures and Standards Effectivecrosssectionmethod Cornerinducedcrosssection

Timber fire design standard methods

Fire Safety of Timber Structures and Standards

Designing a fire resistant structure

Generally, a "stocky" timber structure (i.e. characterized by elements withlow values of the ratio Aexposed/Velement) is inherently better than a lighttimber structure.

This is particularly true when stability issues (Euler buckling of column,lateral-torsional buckling of beam) are involved, since the resistant crosssection decreases and the slenderness significantly increases.

Roberto Tomasi Fire in Timber Structures 11.05.2017 45 / 45