Page 1: FIRE FIGHTING Introduction Fighting fire is not a tasking for RCM-SAR. However knowledge of how to deal with a fire is important, should there be a fire.

FIRE FIGHTING

Page 2: FIRE FIGHTING Introduction Fighting fire is not a tasking for RCM-SAR. However knowledge of how to deal with a fire is important, should there be a fire.

Introduction

• Fighting fire is not a tasking for RCM-SAR.

• However knowledge of how to deal with a fire is important, should there be a fire on the rescue vessel, or the rescue vessel is called upon to rescue survivors from a vessel on fire.

Page 3: FIRE FIGHTING Introduction Fighting fire is not a tasking for RCM-SAR. However knowledge of how to deal with a fire is important, should there be a fire.

Fire

Page 4: FIRE FIGHTING Introduction Fighting fire is not a tasking for RCM-SAR. However knowledge of how to deal with a fire is important, should there be a fire.

Fire Tetrahedron

• Most fires need at least four components to survive. These are :

1. Heat

2. Fuel

3. Oxygen

4. Chain reaction• Fire extinguishing is based on removing or

interfering with at least one of these items

Page 5: FIRE FIGHTING Introduction Fighting fire is not a tasking for RCM-SAR. However knowledge of how to deal with a fire is important, should there be a fire.

Fire Tetrahedron

For example:

Remove the air by using a fire blanket or by putting a layer of foam.

Remove the heat by using water to reduce the temperature.

Remove the fuel, by turning off the fuel valve, or pulling combustibles away so there is nothing less to burn

Page 6: FIRE FIGHTING Introduction Fighting fire is not a tasking for RCM-SAR. However knowledge of how to deal with a fire is important, should there be a fire.

Fire Tetrahedron

• There is a fourth section which is where a extinguishing chemical such as halon can interfere with the chemistry of combustion, and this produces the “fire tetrahedron”.

Page 7: FIRE FIGHTING Introduction Fighting fire is not a tasking for RCM-SAR. However knowledge of how to deal with a fire is important, should there be a fire.

Fire Tetrahedron

Page 8: FIRE FIGHTING Introduction Fighting fire is not a tasking for RCM-SAR. However knowledge of how to deal with a fire is important, should there be a fire.

In Case of Smoke or Fire

• FIND - the fire, location and size• INFORM - inform everyone on board - make

distress call to other vessels • RESTRICT - stop air supply by closing doors,

hatches, windows, air ventilation, fuel cocks, turn off batteries, and turn vessel to blow smoke and flames over the side

• EXTINGUISH - use appropriate fire fighting system available.

Page 9: FIRE FIGHTING Introduction Fighting fire is not a tasking for RCM-SAR. However knowledge of how to deal with a fire is important, should there be a fire.

Fire Extinguishers

Page 10: FIRE FIGHTING Introduction Fighting fire is not a tasking for RCM-SAR. However knowledge of how to deal with a fire is important, should there be a fire.

Fire Extinguishers

Page 11: FIRE FIGHTING Introduction Fighting fire is not a tasking for RCM-SAR. However knowledge of how to deal with a fire is important, should there be a fire.

Objectives

• IDENTIFY 3 common classes of fires

• SELECT the proper type of extinguisher

• EVALUATE when it is safe to

fight an “early-stage” fire, and;

• APPLY the “P.A.S.S. method to operate a portable extinguisher.

Page 12: FIRE FIGHTING Introduction Fighting fire is not a tasking for RCM-SAR. However knowledge of how to deal with a fire is important, should there be a fire.

Untrained People cannot use a fire extinguisher safely because

they are:

• UNABLE to evaluate a fire

• UNAWARE of DANGER due to...

• LACKING JUDGEMENT regarding:

– Safe and correct use of, and

– Limitations of portable extinguishers

Page 13: FIRE FIGHTING Introduction Fighting fire is not a tasking for RCM-SAR. However knowledge of how to deal with a fire is important, should there be a fire.

Why Untrained PeopleCan’t use a fire extinguisher safely

(continued):

INEXPERIENCED• Don’t know about the proper

type of extinguisher • Don’t know how to make a

“Fight or Flight” analysis• Unfamiliar with the “P.A.S.S.

method”

Page 14: FIRE FIGHTING Introduction Fighting fire is not a tasking for RCM-SAR. However knowledge of how to deal with a fire is important, should there be a fire.

Fire Classifications

“Ordinary” combustibles Paper, wood, rubber, plastics

and textiles.

“Flammable liquids” Oil, gasoline, solvents

“Energized circuits”

Electrical equipment and computers

Page 15: FIRE FIGHTING Introduction Fighting fire is not a tasking for RCM-SAR. However knowledge of how to deal with a fire is important, should there be a fire.

Fire Classifications

““Combustible Metals”Combustible Metals”

Certain combustible metals such as sodium, magnesium, potassium, etc. You should not generally meet this type of fire.

Page 16: FIRE FIGHTING Introduction Fighting fire is not a tasking for RCM-SAR. However knowledge of how to deal with a fire is important, should there be a fire.

How They Work:

Works by Works by cooling.cooling. Numerical rating indicates amount of agent, duration, and

range of discharge on test fires.Area of Class A fire which a “non-expert” can extinguish, Area of Class A fire which a “non-expert” can extinguish,

with proper trainingwith proper training 1-A is 1-A is equivalent on Class-A fire to five liters of waterequivalent on Class-A fire to five liters of water. . 22-A contains has -A contains has twice as muchtwice as much extinguishing agent. extinguishing agent.

Page 17: FIRE FIGHTING Introduction Fighting fire is not a tasking for RCM-SAR. However knowledge of how to deal with a fire is important, should there be a fire.

How They Work:

Works by blanketing the fuel. Works by blanketing the fuel. Interrupts chemical reaction at fuel surface.Interrupts chemical reaction at fuel surface.

Class B ratings signify the Class B ratings signify the area in square feetarea in square feet of of flammable liquid fire a unit will extinguish when used, by a flammable liquid fire a unit will extinguish when used, by a

trained, “non-expert.”trained, “non-expert.”

Page 18: FIRE FIGHTING Introduction Fighting fire is not a tasking for RCM-SAR. However knowledge of how to deal with a fire is important, should there be a fire.

How They Work:

Class “C” units have no numerical rating.A Class “C” rating doesn’t imply any capacity.

Only indicates that the extinguishing agent is Only indicates that the extinguishing agent is non-non-conductiveconductive, safe on energized equipment., safe on energized equipment.

Works by displacing oxygen, smothering fire.

Page 19: FIRE FIGHTING Introduction Fighting fire is not a tasking for RCM-SAR. However knowledge of how to deal with a fire is important, should there be a fire.

How They Work:

2A10BC

This is a comparison type of rating system and, in this case, it means that this extinguisher will put out 2 units of a class 'A' fire, 10 units of a class 'B' fire, and that it is rated for use on class 'C' fires. No value is assigned for class 'C', as it only implies that the extinguisher is safe and effective for use on live electrical fires.

Page 20: FIRE FIGHTING Introduction Fighting fire is not a tasking for RCM-SAR. However knowledge of how to deal with a fire is important, should there be a fire.

Underwriter Laboratories of Canada

All Canadian extinguishers will have the above symbol

Page 21: FIRE FIGHTING Introduction Fighting fire is not a tasking for RCM-SAR. However knowledge of how to deal with a fire is important, should there be a fire.

Portable Fire Extinguishers

LIMITED IN:

• Capacity - 1.5 to 25 lbs. of

extinguishing agent

• Range - Typically 3 to 15 feet

• Duration - Discharge their

contents in only 5 to 30

seconds!

Page 22: FIRE FIGHTING Introduction Fighting fire is not a tasking for RCM-SAR. However knowledge of how to deal with a fire is important, should there be a fire.

Extinguisher Common Features

• Locking pin• Carrying handle / operating lever • Pressure gauge• Label :

– Type (Water, C02, Dry Chemical)– Classification (A, B, C)– Capacity Rating– Instructions

• Discharge nozzle or horn

Page 23: FIRE FIGHTING Introduction Fighting fire is not a tasking for RCM-SAR. However knowledge of how to deal with a fire is important, should there be a fire.

Common Types Of Fire Extinguishers

• WATER • DRY CHEMICAL• CO2 and Halon

Page 24: FIRE FIGHTING Introduction Fighting fire is not a tasking for RCM-SAR. However knowledge of how to deal with a fire is important, should there be a fire.

Water Extinguisher

• Water + CO2 propellant

• ONLY for Class firesONLY for Class fires

– wood / paper, etc.

• Spreads burning liquids!

• DANGERDANGER of electric shock if used on on live circuits!

Page 25: FIRE FIGHTING Introduction Fighting fire is not a tasking for RCM-SAR. However knowledge of how to deal with a fire is important, should there be a fire.

Dry PowderMulti-Purpose Rated

• Best for general use:

• Reduced risk of re-ignition

• A 10 lb. unit empties in 8-10 secs.

– Effective range of 6 ft. to 15 ft.

Either Or

Page 26: FIRE FIGHTING Introduction Fighting fire is not a tasking for RCM-SAR. However knowledge of how to deal with a fire is important, should there be a fire.

Carbon Dioxide - Rated

• Best on burning liquids / electrical

• SHORT range - 3 to 8 ft.

• 10- pound unit empties in 5 to 10 seconds!

– Use short spurts!

• DISPERSES QUICKLY!

– Continue applying after the fire is out!

• Unit gets VERY cold - hold properly

Page 27: FIRE FIGHTING Introduction Fighting fire is not a tasking for RCM-SAR. However knowledge of how to deal with a fire is important, should there be a fire.

Halon Extinguisher

• Best for computers / electronics

• Weight-for-weight TWICE as effective as C02

• No residue, easy clean-up

• VERY SHORT range, 3 to 6 ft.

• Like C02, Discharges QUICKLY!

• Like C02, Disperses QUICKLY!

– Continue after flames are extinguished

Page 28: FIRE FIGHTING Introduction Fighting fire is not a tasking for RCM-SAR. However knowledge of how to deal with a fire is important, should there be a fire.

P.A.S.S.

Page 29: FIRE FIGHTING Introduction Fighting fire is not a tasking for RCM-SAR. However knowledge of how to deal with a fire is important, should there be a fire.

P.A.S.S.PULL

AIM

SQUEEZE

SWEEP

Remember 1) Keep your back to a clear escape route,2) Stand back 6 to 8 feet from the fire,3) Stay low below heat,4) Then >>:

Page 30: FIRE FIGHTING Introduction Fighting fire is not a tasking for RCM-SAR. However knowledge of how to deal with a fire is important, should there be a fire.

PULL the pin

Page 31: FIRE FIGHTING Introduction Fighting fire is not a tasking for RCM-SAR. However knowledge of how to deal with a fire is important, should there be a fire.

AIMLOW at the base of the fire

Page 32: FIRE FIGHTING Introduction Fighting fire is not a tasking for RCM-SAR. However knowledge of how to deal with a fire is important, should there be a fire.

SQUEEZEthe lever

Page 33: FIRE FIGHTING Introduction Fighting fire is not a tasking for RCM-SAR. However knowledge of how to deal with a fire is important, should there be a fire.

SWEEPfrom side to side

Page 34: FIRE FIGHTING Introduction Fighting fire is not a tasking for RCM-SAR. However knowledge of how to deal with a fire is important, should there be a fire.

Servicing

• All extinguishers should be serviced annually

Page 35: FIRE FIGHTING Introduction Fighting fire is not a tasking for RCM-SAR. However knowledge of how to deal with a fire is important, should there be a fire.

Approaching a Fire

Page 36: FIRE FIGHTING Introduction Fighting fire is not a tasking for RCM-SAR. However knowledge of how to deal with a fire is important, should there be a fire.

Approaching a Fire

• Where the rescue vessel has been called to a burning vessel, conduct the Stop, Assess, Plan, looking for survivors, the source of the fire, and any items such as propane tanks, fuel tanks or diving tanks that are liable to explode.

Page 37: FIRE FIGHTING Introduction Fighting fire is not a tasking for RCM-SAR. However knowledge of how to deal with a fire is important, should there be a fire.

Approaching a Fire

Page 38: FIRE FIGHTING Introduction Fighting fire is not a tasking for RCM-SAR. However knowledge of how to deal with a fire is important, should there be a fire.

Approaching a Fire

• Always approach from windward of the casualty that is on fire, if circumstances permit, to stay out of the smoke.

• If survivors are still on board, urge them to don lifejackets, and jump off to windward to recover them from the water.

Page 39: FIRE FIGHTING Introduction Fighting fire is not a tasking for RCM-SAR. However knowledge of how to deal with a fire is important, should there be a fire.

Water Wall•It is not work of RCM-SAR to extinguish vessel fires, but to recover survivors.

•RHIBs are not designed for fire-fighting.

•If an approach has to be made to a burning vessel to recover a survivor, one use of the de-watering pump is to generate a “water wall”.

•The hose nozzle will be adjusted to form a spray pattern, also called "water wall" and will protect the tubes and the personnel from radiant heat).

Page 40: FIRE FIGHTING Introduction Fighting fire is not a tasking for RCM-SAR. However knowledge of how to deal with a fire is important, should there be a fire.

Water Wall

Page 41: FIRE FIGHTING Introduction Fighting fire is not a tasking for RCM-SAR. However knowledge of how to deal with a fire is important, should there be a fire.

• WATCH the fire area– If the fire flares up, back out immediately and call

the fire department!

OK, It’s out…Now What?