Fire Alarm Panel JAY JE 190 - Synopsys...

2
Synopsys A001, Fre Mumbai4 Fire A JAY Salien T T T T T B T fo Tech Pvt. Ltd essia CHS LTD 400068. Tel. 0 Alarm P JE190 nt Featu he panel he panel he panel he panel he panel Battery ba he panel or fault a d. D, Baburao Ra 0222890450 Panel 0 ures :- l ranges l compli l has sep l also ha l compri ackup is l is equip and fire. anade Marg, O 00/6800/6500 from 2 t ies with parate fir as separa ises of a s provide pped wit Off. L.M. Roa 0 Email :info to 64 zon IS 2189 re and fa ate fire an 2Amp p ed along th a 24V d, Behind Ban o@synopsyste nes. specific ault indic nd comm power su with the VdC piez nk of India, D ech.com cation. cations. mon faul upply un e AC sup zoelectric ahisar West, lt relay. nit. pply. c buzzer r

Transcript of Fire Alarm Panel JAY JE 190 - Synopsys...

Page 1: Fire Alarm Panel JAY JE 190 - Synopsys Techsynopsystech.com/products/FAP/FAP_Datasheet/FAP190_Datasheet.pdf · Synopsys A‐001, Fre Mumbai‐4 Fire A JAY Salien • T • T • T

 

Synopsys A‐001, FreMumbai‐4 

Fire A

JAY Salien

• T• T• T• T• T• B• T

fo

Tech Pvt. Ltdessia CHS LTD400068. Tel. 0

Alarm P

 JE‐190

nt Featu

he panelhe panelhe panelhe panelhe panel

Battery bahe panel

or fault a

d.  D, Baburao Ra022‐2890450

Panel     

ures :- 

l ranges l complil has sepl also hal compriackup isl is equipand fire.

anade Marg, O00/6800/6500

             

from 2 ties with parate firas separaises of a s providepped wit

Off. L.M. Roa0 Email :‐ info

      

to 64 zonIS 2189 re and faate fire an

2Amp ped along th a 24V

d, Behind Bano@synopsyste

nes. specific

ault indicnd commpower suwith the

VdC piez

nk of India, Dech.com 

cation. cations. mon faulupply une AC supzoelectric

ahisar West, 

 

lt relay.nit. pply. c buzzer

         

r

Page 2: Fire Alarm Panel JAY JE 190 - Synopsys Techsynopsystech.com/products/FAP/FAP_Datasheet/FAP190_Datasheet.pdf · Synopsys A‐001, Fre Mumbai‐4 Fire A JAY Salien • T • T • T

 

Synopsys Tech Pvt. Ltd.  A‐001, Fressia CHS LTD, Baburao Ranade Marg, Off. L.M. Road, Behind Bank of India, Dahisar West, Mumbai‐400068. Tel. 022‐28904500/6800/6500 Email :‐ [email protected]  

Technical Specifications:- INTERNAL POWER SUPPLY UNIT • Constant potential battery charger 27.5V DC Adjustable • Output Current limited to 2 A • Low battery voltage monitored at 18 V DC Adjustable • Battery charger monitoring for failure • Mains supply monitoring for failure • Mains supply input voltage range 230V AC + or – 10 %, 50 Hz • Total panel quiescent current 50mA nominal • Approx. Standby time 4.5 Ah Batt. 36 hrs. • Battery recharge time from discharge 1 Hr. approx.

INTERNAL RELAY CONTACT RATING • Fire Relay 5 Amp. S.P. 240 V DC • Common fault relay 5 Amp. S.P. 240 V DC • Aux. Fire relay 5 Amp. S.P. 240 V AC

Panel Indications:-

• System ON Green LED - System normal • Common Fault Amber LED – Internal buzzer will sound intermittently • Common Fire Red LED - Detector activated • Zone fault Amber LED – Indicates zone wiring and detector faults • Zone fire Red LED – indicates zone where fire has been detected • AC fail Amber LED – Indicates loss of mains • DC fail Amber LED – Indicates battery fault • Batt. Low Amber LED – Indicates battery supply below 18V DC

EXTERNAL CONTROLS:- • Sound - To sound external as well as internal sounders. • Silence -To silence external as well as internal sounders. • Reset -Lamp test & resets the panels. • Isolate -the zone to add/clean detectors. • Test -International standard walk test.