An Evaluation Of The Second Generation Consolidation Monitoring Device Final Report Project HR-1013 January 1984 Highway Division Iowa Department ----- of Transportation

Transcript of Final Report Project HR-1013 - Iowapublications.iowa.gov/19872/1/IADOT_hr_1013_Second... · final...

Page 1: Final Report Project HR-1013 - Iowapublications.iowa.gov/19872/1/IADOT_hr_1013_Second... · final report for iowa department of transportation research project hr-1013 conducted for

An Evaluation Of The

Second Generation Consolidation Monitoring

Device Final Report

Project HR-1013

January 1984 Highway Division

~tlA Iowa Department ----- ~'l of Transportation

Page 2: Final Report Project HR-1013 - Iowapublications.iowa.gov/19872/1/IADOT_hr_1013_Second... · final report for iowa department of transportation research project hr-1013 conducted for

AN EVALUATION OF THE SECOND GENERATION

CONSOLIDATION MONITORING DEVICE

FINAL REPORT FOR

IOWA DEPARTMENT OF TRANSPORTATION RESEARCH PROJECT HR-1013

CONDUCTED FOR THE U.S. DEPARTMENT OF TRANSPORTATION

FEDERAL HIGHWAY ADMINISTRATION

UNDER -J)lf.J{lthl.::5&=-H\"'4'17'

BY RICHARD M, REISNER

HIGHWAY ENGINEER TRAINEE

UNDER THE DIRECTION OF VERNON J, MARKS

RESEARCH ENGINEER (515) 239-1447

OFFICE OF MATERIALS HIGHWAY DIVISION

IOWA DEPARTMENT OF TRANSPORTATION AMES, IOWA 50010

JANUARY 4, 1984

Page 3: Final Report Project HR-1013 - Iowapublications.iowa.gov/19872/1/IADOT_hr_1013_Second... · final report for iowa department of transportation research project hr-1013 conducted for

INTRODUCTION

The Consolidation Monitoring Device (CMD) was developed for the Federal

Highway Administration (FHWA) to continuously monitor the density of

plastic portland cement concrete immediately following placement by a ·~~~,.,,.

paving machine. The device is attached to the rear of a paving machine.

As the strength, chemical resistance, and life of PC concrete are affected

by the density, it would be very beneficial to know the density of t~~---1

) ,

plastic concrete. If y.e concrete were @ut of{;-;;;;W;;;~-c·~;:;-~;t ion"}· ~(;,s '1'1 .,J) ' ~CY

of the prob 1 em would be more economical while the concrete was in the 1,li' ~,,.~'

plastic state.

The prototype CMD was field tested in Iowa in 1978. It was concluded that

the impossible task of maintaining the necessary one-inch air gap was the

probable cause for the poor field correlation with core densities.

To overcome the air gap problem, a method to electronically compensate the

density reading for air gap variation was developed and added to the

system. The second generation CMD was ready for field testing and in July

of 1983, Iowa was again selected as a test site.

OBJECTIVE

The objective was to evaluate the usefulness, accuracy, precision, and

reproducibility of the second generation CMD for PC concrete under

production conditions.

,·. 1'i('''

Page 4: Final Report Project HR-1013 - Iowapublications.iowa.gov/19872/1/IADOT_hr_1013_Second... · final report for iowa department of transportation research project hr-1013 conducted for

SYSTEM DESCRIPTION

The second generation CMD was developed for the FHWA by Foster-Miller,

Inc. of Waltham, Massachusetts. The system consists of a control and

readout unit; a radioactive source and a photomultiplier (PMD) tube which

are placed in a lead shield carrier (source-sensor unit); a flat

capacitance distance transducer; traversing mechanism; and associated

cables.

The control and readout unit contains the circuitry, battery, controls,

and meters for operating the CMD. A chart recorder is also enclosed in

the same case (Fig. 1).

A hinged guide beam is mounted on the rear of the paver. The hinged

mounting allows the beam to follow the cross-section of the pavement. The

source-sensor unit containing the radioactive source, PMD tube and the

flat capacitance distance transducer are placed in a motor driven

carriage. The carriage can traverse at variable speeds or be held in a

stationary position on the guide beam.

Fig. 1 - Control & Readout Unit

Page 5: Final Report Project HR-1013 - Iowapublications.iowa.gov/19872/1/IADOT_hr_1013_Second... · final report for iowa department of transportation research project hr-1013 conducted for

Gamma rays from the Cesium 137 radioactive source are emitted downward

into the concrete (Fig 2). The number of gamma rays reflected and

detected by the PMD tube are dependent upon the density of the concrete.

,The result is converted to density and read as lbs/cu ft on a meter and

recorded on the strip chart.

SOURCE

SENSOR

+ I I A IR GAP \ '---i:::::::::P::RO::B:::E =:ii'

I

L AIR GAP r ---· 4 • • • • . ~. . ~ ' " .

..) " • D • t) • • ' . ' . ·"' .

~ "' • r . , • ! L' • ,.. " • I ... { I . -· .. I . ' . I . ,, .. · . J. ' . 1,: () . --0 . l

.l·---··· r...r -, • . • ' . ' ' r·

Fig. 2 - Typical Gamma Ray Path

The air gap between the source-sensor unit and the pavement surface was a

critical factor on the first generation CMD. An air gap probe on the

second generation CMD measures the air gap by means of changes in

capacitance between the probe and concrete surface. The density reading

is compensated to a one-inch air gap. The compensated air gap range is

one inch ± 0.4 inch. If the air gap leaves this range, the recorded

density will not be correct.

Page 6: Final Report Project HR-1013 - Iowapublications.iowa.gov/19872/1/IADOT_hr_1013_Second... · final report for iowa department of transportation research project hr-1013 conducted for

Laboratory Evaluation

The laboratory testing consisted of:

1. Determining the radiation emission from the radioactive source in the source-sensor unit.

2. Calibrating the CMD according to the instruction manual~~?PcN~';.X A-) p

3.

4.

5.

Comparing the CMD with a

Determining the depth of

Determining the area of

6. Determining the effects gap probe.

7. Determining the effects

Radiation Exposure

commercial nuclear gauge.

influence of the CMD.

influence of th~ CMD (edge effects).

of changes in air gap without the air

of varying the time constant.

Radiation exposure is the first concern when operating radioactive

devices. To determine radiation exposure, the source-sensor unit was

placed on the calibration block in the operating mode and measurements AT

were made at six different distances (Fig. 3).v Two feet from the

source-sensor unit the radiation exposure is 0.7 mr/hr and at three

feet the radiation exposure is 0.5 mr/hr.

Personnel working with the CMD were required to wear film badges to

monitor radiation exposure. The film badges of two people that were

associated with the CMD part time showed zero radiation exposure. The

person involved full time with the CMD received a total of 60 millirem

during a two-month period (Appendix B).

Page 7: Final Report Project HR-1013 - Iowapublications.iowa.gov/19872/1/IADOT_hr_1013_Second... · final report for iowa department of transportation research project hr-1013 conducted for

10.0,

'9.0,

:a.o . .

---: 7.0

2.0\

i 1.0'

-- _____ fie,--· 3~------ ·-- - --i RADIATION EXPOSURE i : IN THE OPERATING MODE i

.o:+.,.......,r--r.::;:~::;=;i=i'------­-°-~ :1_~1~f-'4. 011-61;-·nriru--eu·10L-.-----

Distance From Source In Source/Sensor Unit, Feet I '--1····. - , -· --

The exposure limit for radiation workers for sensitive regions (whole

body, gonads, eyes, skull) is 96 millirem per week. Some typical

radiation exposures are: 2

chest x-ray tooth x-ray jet flight NY-SF background in Iowa (avg.)

100 mi 11 i rem 10-30 mi 11 i rem 3 mi 11 i rem 0.33 millirem/day

A leak test was performed before evaluation and prior to shipment to

Texas. No leakage was measured in either test indicating the CMD is

safe when properly used.

l J__ tn·structional Manual MC-1 Simultest Compaction Gauge, Campbell ~£'ific Nuclear Cor., Pachico, CA, 11/76, pp 3, pink section. -

Page 8: Final Report Project HR-1013 - Iowapublications.iowa.gov/19872/1/IADOT_hr_1013_Second... · final report for iowa department of transportation research project hr-1013 conducted for

Laboratory Calibration

The laboratory calibration consisted of three steps. The first step

was to calibrate the CMD on fresh concrete samples using the same

aggregates and mix (Appendix C) as used in the paving project. This ~-

~to negate the effects of aggregate composition on the CMD

readings. Densities were measured with the CMD (Fig. 4) and a

Campbell Pacific nuclear gauge (Fig. 5). Three concrete samples (high

density-low air, normal, and low density-high air) were prepared to

calibrate the CMD. The calculated densities were 154.1 lbs./cu.ft.

for the high density mix, 143.7 lbs./cu.ft. for the normal mix, and

137.0 lbs./cu.ft. for the low density mix. The CMD was adjusted to

correspond with the above calculated densities. The range was

sufficient to cover densities of concrete placed during field testing.

Fig. 4 - Laboratory Calibration of the CMD

Page 9: Final Report Project HR-1013 - Iowapublications.iowa.gov/19872/1/IADOT_hr_1013_Second... · final report for iowa department of transportation research project hr-1013 conducted for

Fig. 5 - Laboratory Correlation with a Campbell Pacific Nuclear Gauge

The second step involved the magnesium-aluminum calibration block.

Immediately after calibration on fresh concrete, the source-sensor

unit was placed on the calibration block and 136 lbs/cu ft were

indicated. A steel insert was then placed on the calibration block

giving a second density reading of 161 lbs/cu ft.

The calibration block readings are recorded for field calibration.

Each morning before field testing the CMD was placed on the

calibration block and adjusted, if needed, to the above values. This

was to eliminate day-to-day drift in the electronics.

Page 10: Final Report Project HR-1013 - Iowapublications.iowa.gov/19872/1/IADOT_hr_1013_Second... · final report for iowa department of transportation research project hr-1013 conducted for

The last step is to correct any electronic drift during testing. A

function switch that has the positions of cal high and cal low allows

the testing personnel to check the electronics for variations while on {\[.,

. . l d 1" is s1mu ate d ··\ the paver. In the "cal" positions a density signal ,.. I, ,.(. ,.

within the control and readout unit. t \' ~.

( }. ,\ .~~ t,.r' check'.;> the ~e ,r1t,. ., ',' \

I ·' ,. .. · . .,,".' ',. (

.· \; \ '.>)' \ 1)

I ' 1 V\,

~t. After calibration on the calibration block, the function

switch is turned to cal high and cal low and the density readings

recorded, in this case 159 lbs/cu ft and 137 lbs/cu ft were indicated

respectively. During field testing if cal high or cal low are outside

the designated reading by more than 2.0 lbs/cu ft, the CMD should be

adjusted to the original calibration values. After calibration, very

little adjustment was needed.

Depth of Influence

The CMD, being a radiation backscatter device, has limitations to the I !'I (t.. l·!f. !IC/;.

depth of H.~~::n;::o:tkJS. To determine this depth, various thicknesses

of concrete having a density of 148 lbs/cu ft were placed over a steel

plate having a density of 484 lbs/cu ft and the density readings

recorded. Density on concrete of thicknesses less than 2-1/2" could

not be recorded as the readings were off the scale. To obtain more

data, 1/2'' and l" thick pieces of neoprene, density of 79.2 lbs/cu ft

and 83.5 lbs/cu ft respectively, were placed over a standard granite

block, density of 165.5 lbs/cu ft, and the density readings

recorded. A depth of influence graph was developed (Fig. 6). The

surface of the concrete has the greatest influence over the density

reading and the influence decreases rapidly with depth. i eorl\

percent of the density reading is ~m4R~ the top f 1? ·.'.Jr,..\_

and 85% Jiff the top 2".

Seventy

l" of concrete

,./ 11 0 ' v .~: f (\'

'.}

Page 11: Final Report Project HR-1013 - Iowapublications.iowa.gov/19872/1/IADOT_hr_1013_Second... · final report for iowa department of transportation research project hr-1013 conducted for

100

'eo'

so'

70

: 0>'

'.s "O

' "' ' QJ a: 0

50 QJ '

~L c 40

30,

20.

___ £t<l. ~ . ·------·--. DEPTH OF INFLUENCE I

c.c. o.993291 I STANDARD ERROR 2.14060 t

rl 4/ . 5---! Dept~,_lnches i

Areas of Influence (Edge Effects)

All nuclear gauges become innacurate as the area of influence

intercepts a vertical edge. A test conducted on a fresh concrete

sample determined that 7" from the source to the edge are required to

eliminate the edge effect. During field testing, the CMD could not

traverse closer than six feet to the pavement edge because a paver

brace limited the carriage traverse.

Page 12: Final Report Project HR-1013 - Iowapublications.iowa.gov/19872/1/IADOT_hr_1013_Second... · final report for iowa department of transportation research project hr-1013 conducted for

Air Gap Characteristics

--;:::: I ;:J --

• ~ ' 155.01

<nl·-­.D I -- -;, I __ -_ ~ i 154.ol c, --· Q) I

oi '

152.0'

The major problem of the first generation CMD was keeping a constant

l" t 1/16" air gap. If the air gap deviated from this range, the

density reading was dramatically affected. The second generation CMD

air gap characteristics were investigated. Varying the air gap 0.05"

will change the non-compensated density reading 0.62 lbst1curtt·~ (Fig.

7). With the air gap compensation of the second generation CMD, very

few adjustments were necessary to maintain the required air gap during

field testing.

151.0'-t---:ir---.--r---r--...----.---.----..----..::::0.-.1... .

.so: .85' .90. .95i 1.00 1.05 1.10 1.15 ! 1:20: ..:.. . .:.-~. --- -·-·"---

Air Gap, Inches

J )

Page 13: Final Report Project HR-1013 - Iowapublications.iowa.gov/19872/1/IADOT_hr_1013_Second... · final report for iowa department of transportation research project hr-1013 conducted for

Time Constant Characteristics

A time constant switch on the control and readout unit having three

positions -- 2, 3, and 5 seconds, averages the density signal over the

designated time. The constant has a direct relationship to the

density trace recorded on the strip chart. A longer time constant

evaluates a larger area of pavement tending to give a smoother

trace. The time constant for field testing was five seconds._\ The v<f1'4'\t-CR\I j

density trace of the second generation CMD has greate~lariations than

the first generation CMD when comparing both at the same time constant

setting. The characteristics for the different time constants are

shown be l ow(F l<.r <g-/.l) .'

tWiiiiiiiillil:t F 16 $ ..!J?race auring Q. 5 second ~-ngJf- of:°

tzlk'i-1- eJ.tst•¥'f-ZS r1Qe&o+:;fuJ'' D DFNsrry 77r;acc OF TY-£ FIRS'/ 6--F/Vt:R/4-7zo# CIM /) ~ T O<) ~~

.// · s·Eco;V'() S:/I::r;t7.-V(7-

Page 14: Final Report Project HR-1013 - Iowapublications.iowa.gov/19872/1/IADOT_hr_1013_Second... · final report for iowa department of transportation research project hr-1013 conducted for

Fhel!s g Fl6-/0

tJ1;: ;US? 'f'Y'"'-''i£~,~;q(;fii'} 1c1J tf1- 'TlfE 'f::7esr 6-r/V.e.e /4''121Ytr

C/IVI (J fJ.:r T/;11£ :(§- '}i: colfp 'S'ET/71Y6-

12

Page 15: Final Report Project HR-1013 - Iowapublications.iowa.gov/19872/1/IADOT_hr_1013_Second... · final report for iowa department of transportation research project hr-1013 conducted for

:;

~' .. "' ....

·7.

.. -...

-

' ....... ,_ -,.,, .. '-· : _. ....

. :,!.•.' -; :• .. -

'·'·"'- '.: ... :• , ..

·-l•l-!l an 1H~

, .. .. -. l:C''Y f ~ ·' "t .. 1fV .

, .. ,_ .... I··•; - ,_,, ......

... ' ._, .. ,_

-- '. '"· 1fh : ; : ·'·:: · .. · . . T '' X

'

.. .· ::· I •:: .: .. :.::: "•" ; . "' --<i> ... ... ·-

' .. · .. , .. , .. .:•••c " , __ .. ,. I" ..,, ... ....

.

....

~.:.:1 ·::;; .:

-- • ...L......L..

'"'" ,_ )-

FlfF I/

'."fi)rsJvS./T'/~ 77:.fitA~ aEJtf!litti/vii:E.~IPP~i@-Ei:?'f/b/t,477CJ/{}

c /11 !!J !!§:74~e-r #'..LPNJ;fR ~B3t:Yo/if.JJ:c;S£r

'p $If! 51 Pl: TlF!f!C:-1§: '.t:A:t?CJ F.;? .~1:S::q:;;:~:&rl:;}J"'P~ A!6'~t7,.J .s~'""rff-vw'El~fl--'&J33&'t:?7V'lli:J.ht~/l/6-. >··-

Page 16: Final Report Project HR-1013 - Iowapublications.iowa.gov/19872/1/IADOT_hr_1013_Second... · final report for iowa department of transportation research project hr-1013 conducted for

Field Evaluation

The field evaluation was conducted during the paving of Iowa 330 from

U.S. 65 to U.S. 30 in Jasper and Marshall counties in September of

1983. The contractor, Fred Carlson, Inc. of Decorah, Iowa, used an

STR REX slip form paver on which the CMD was mounted (Fig. 13).

Fig. 13 - Field Evaluation of the CMD

The hinged guide beam as received was 25 feet long, making it

impossible to mount between the 24-foot wide forms of the REX paver.

It was necessary to cut 1-1/2 feet from each end of the beam and drill

new holes for the magnetic direction change system. This was

accomplished in the Iowa DOT Materials machine shop. It was also

necessary to weld channel iron sections to the top of the extrusion

meter on the paver to support the guide beam at the required

elevation.

)

Page 17: Final Report Project HR-1013 - Iowapublications.iowa.gov/19872/1/IADOT_hr_1013_Second... · final report for iowa department of transportation research project hr-1013 conducted for

Because of the size of the source-sensor carriage, the CMD could not

traverse past the extrusion meter supports; therefore, only the middle

11-1/2 feet of pavement could be monitored. The ability of the second

generation CMD with a hinged guide beam to cross over the pavement

crown and monitor both sides of the pavement was demonstrated.

Mounting of the guide beam is not readily adaptable to all pavers as Y"0::""'"'-?

desired. Of three pavers considered for field evaluation, the STR REX

paver was the easiest to mount the guide beam, f!\1·

Project Mix Design

The original mix design was a C3WR, but was changed to a C5WR mix.

The coarse aggregate (gravel) and fine aggregate (natural sand) came

from Hallet at Clemons.

Mix Proportions for C5WR Approximate Quantities per Cubic Yard

Cement water Air (Daravair R.) Fine Aggregate Coarse Aggregate WR (WRDA/HYCOL)

Operating Procedure

618 lbs. 266 lbs. 6.57 oz. 1634 lbs. 1337 lbs. 24. 72 oz.

0.3090 ton

0.8170 ton 0.6680 ton

Field testing began on September 1, 1983, on Iowa 330. The first day

was spent becoming acquainted with the field opera ti on µi..es1'i'Elmie: The •

CMD electronics failed on the third day of field testing and repairing

took longer than a week.

I

Page 18: Final Report Project HR-1013 - Iowapublications.iowa.gov/19872/1/IADOT_hr_1013_Second... · final report for iowa department of transportation research project hr-1013 conducted for

Each morning 30 minutes were required for set-up and calibration.

Set-up consisted of installing the control and readout unit, source,

and signal cables. Calibration consisted of adjusting the CMD to the

recorded values for the calibration block. After each day of use, the

control and readout unit, source, and signal cables were removed. The

internal battery for the control and readout unit required recharging

after each day of use.

Load Transfer Devices

Achievement of adequate consolidation of the concrete around load

transfer devices was questioned by Iowa DOT personnel. No noticeable

difference in density could be detected as the CMD passed over a load

transfer device.

GMO-Campbell Pacific Nuclear Gauge Correlation

A correlation between the CMD and a Campbell Pacific Nuclear Gauge

(CPN) was determined. The correlation was done with the CPN in two

modes, backscatter and two-inch direct transmission. The results

indicate a relationship but the correlation is not as strong as

anticipated (Figs. 14 and 15).

CMD-Core Correlation

After reviewing the density strip chart, locations were chosen to

drill cores. The 4" diameter cores were cut into slices of 111, 2",

and 4" thick to check for varying densities in the core. The cores

were tested for density and percent air (Appendix D) and five cores

were tested for strength (Table 1).

/. ·,

Page 19: Final Report Project HR-1013 - Iowapublications.iowa.gov/19872/1/IADOT_hr_1013_Second... · final report for iowa department of transportation research project hr-1013 conducted for

147.0

146.0

145.0

144.0

143.0

;::: 142.0 :::l u ' <fl

:e 141.0 Ol c u ;;; 140.0 a: z a.. () 139.0

138.0

137.0

136.0

135.0

134.0 I •

CMD - CPN CORRELATION Fl6' 1</ BACKSCATTER MODE

STANDARD ERROR 1.72 lb/cu ft -------- - -. __ c_~c._Q.]'_39 _.

_1}3.Q-+--..----.---..----.---,.---.---,.---.---..----.---..---,..--..---,..--.,.---,..-----

1136.0 137.o 138.o ·139.o ·140.0 141.0, 1142.0 \143 .. o 14~._o 145.o .. :~46.o 147:0 :148.0 149.o ,150.0 151.0 ·152.0

CMD Readi~g: l~s/cu ft

Page 20: Final Report Project HR-1013 - Iowapublications.iowa.gov/19872/1/IADOT_hr_1013_Second... · final report for iowa department of transportation research project hr-1013 conducted for

152.0

151.0

150.0

149.0

148.0

"' () 147.0 ,,., 0

°' ::; 14G.O 0 ro Q>

a: z 145.0 Q_

(.)

144.0

143.0

142.0

141.0

140.0

vlVIU - \JS-I'll vvnn~L.M I IVl'I

2" DIRECT TRANSMISSION STANDARD ERROR 1.01 lb/cu ft

c.c. 0.743

Fl~ ''°

139.0-+~~...-~--..--~ ....... ~~..-~--,.~~""T""~~.-~.....,~~""T""~~.-~ ..... ~~...-~--.r--~~~~ 139.o 140.0 141.0 142.0 143.o 144.o 145.o. 146.o 14io: i4s.o 149:0 150.0 ,'J51.o 152.0

-- --- ·--- ~ . ----· -- ......

GMO Reading, lbs/cu ft

Page 21: Final Report Project HR-1013 - Iowapublications.iowa.gov/19872/1/IADOT_hr_1013_Second... · final report for iowa department of transportation research project hr-1013 conducted for

149.0

148.0

147.0

146.0

145.0

"; 144.0 u ~

"' J:l i 14301 • I

c (!)

0 m 142.0- I • ~

0 ()

141.0

140.0

139.0

138~0

137.0

. I

- -------Flik. . :1"

CMD - CORE CORRELATION 4" DIA., TOP 4" _

STANDARD ERROR 0.94928 lbs/cu ft 1

c.c. 0.13543

• • • • .. • • • • •

• • I • •

• • • • • • • • •

• •

136·0 L . L. J_ -L _(__ . L. _L_ _J__ _L I ___[_ ___)_ ::r:: :::J _J_ [ I j _ 136.o 137.o\ 138.o 139.o: 140.0 141.0 142.oi 143.oJ 144.oi /145-:-<\_}46,o'..J147.o\ 114s.o, 1149.o: \150.01 1:rs1.o :-152.0 1153.o

CMD Reading, lbs/cu ft I - -

Page 22: Final Report Project HR-1013 - Iowapublications.iowa.gov/19872/1/IADOT_hr_1013_Second... · final report for iowa department of transportation research project hr-1013 conducted for

151.0

150.0

149.0

148.0

147.0

146.0

~

:J

~ 145.0 :e ?:' ·~ 144.0

'" 0

143.0

142.0

141.0

140.0

139.0

138.0

137.0 • 1 '

• ••

,., I '

'' I \ I \ • I "' 1' • >,• I ',,, . . .... l ' . ~ '

0 ' )I • • • .. •

5

Fltr 1"1

10'

\

' ' \

CMD - CORE CORRELATION

,... ,\ I ,\ I

J.. /

• \ I • v ••

• • • • ••••

..

• ••• • •

• • • • • !t • • I T "' . ,,

;" ' I \ \ I l

• •

i LE-GiND _____ _ . CMD \4" DIA. CORES II FU LL 8" -------TOP 4" · • · · · · · . .

• • •

• ,•! • •

l'I• I '-•

I • 1/ ,, ' . . .

~ . . . 1 • •

\ I ~ '., I >. ........ __ ,,1 ' r . ' . .,

: ',, . ' ... ·' .. ol ol

·' . :/ \ ., \ I ,,

f

15 20 -__ ,_ -

nulj>loo di 01 Ci IC

('ORE <('IUl'f,i3EAe:

<o ,, r'T-z" 't I o

P's\

~v'~ • • • • ••

,-30

•.

!\ • I' • • I \ • • I \ • •

I •' • I •' ', • I• '• I • \ •

I· \· I • \'

\ I• \' •\,. ,. •'f• ,. . . '• . '·

35

\ \ I •

Page 23: Final Report Project HR-1013 - Iowapublications.iowa.gov/19872/1/IADOT_hr_1013_Second... · final report for iowa department of transportation research project hr-1013 conducted for

152.0

151.0·

150.0'

149.o'

14a.o·

... ~ :147.0

1

~

i1_46.0 .... '!45.0

c ·;,;;. j

&i.144.01 o·

143.0

'142.0·

141.0'

139.0

138.0,

• • • •

• •

• .. •

• •

• .. • • • •

, ... ,

• • • • • • •• • •

Rf:r I~

CMD - CORE CORRELATION

• • 1\ • I \ '

I \ ' I \ • •

I \o ._ • I \ • • ,...,,

I \ •• ,,,,, -..., I \ ~ '

I ...... . . . ·-· • • • • •

I \ ;' ................. _,,.-I \ ; ... ...-1 "

,, ', ,, ', ------' '

., ------

LEGEND CMD 4" DIA. CORES TOP 4"------~-TOP_2"········ --------- ---------·.

• • •

,,,. I \I

I \ , , , I ,

I I I I '\\ ........-- ,

~\...--< I "';i!. ........ J

• • • • • • • •

\ . \ . \ . \ .. \ .

\ \ \ \

',

• • .... • • • •

.. •

/' ,//

., ,' ' I ',/

.. . • • .. . ,, ;'

,~----

J31 ; 33 ·~_..:~,..~~r-~-,~~.,.~~.,-~:---r-~"'."'1"""'.'~-,~~-i:::----;-:i::-:----;::~~r,:--~:i;:--~:i::----:;;;~~:,-~~~:--~;-~""ii:--~1 '137_,_Q:. (j

3: 4 ~ 6 '8 I 114 \ \15 \ 28 i17• 1191 :22 i23 i 16 ' !25 10 i :30 36 37

,(i&fl;.c:~r~U&l:-k

Page 24: Final Report Project HR-1013 - Iowapublications.iowa.gov/19872/1/IADOT_hr_1013_Second... · final report for iowa department of transportation research project hr-1013 conducted for

TABLE 1 Strength & Density of 4" Diameter 811 Long Cores

CMD Reading Core Density Strength Station Number lbs./cu.ft. lbs./cu.ft. PSI

184+36 140.0 143.5 3950 185+35 145.0 144.4 4500 188+66 147.5 144.0 4130 207+32 146.0 144.6 4820 215+00 144.0 144.6 5250

The correlation of the CMD with the 8" long cores yielded a standard

error of 0.7885 lbs/cu ft and a correlation coefficient (CC) of f

0.074651, a very low degree0correlation. Since the depth of influence

is 4-1/2", the top 4" of the cores were correlated with the CMD

(Fig. 16). The standard error was 0.94928 lbs/cu ft and a CC of

0.13543, which is better than the 8" core but still exhibits a low

degree of correlation. The top 2" of the core yielded a standard

error of 1.025 lbs/cu ft and a CC of 0.1937 which is better than the

top 4" but sti 11 a low degree of correlation. The CMD-core

correlation is not as good as anticipated. Graphing the CMD and core

density yields an insignificant, but general relationship (Figs. 17

and 18).

Reproducibility

Several tests were conducted to check the reproducibility of the

CMD. In the laboratory the CMD was placed on the calibration block

and the density varied± 1.5 lbs/cu ft (Fig. 19). During field

testing, the CMD was held in a stationary position and the density

again varied± 1.5 lbs/cu ft The density traces were compared at

locations where the paver was stationary and the CMD was traversing.

The CMD would reproduce the density trend, but would show substantial

differences in individual locations (Fig. 20).

Page 25: Final Report Project HR-1013 - Iowapublications.iowa.gov/19872/1/IADOT_hr_1013_Second... · final report for iowa department of transportation research project hr-1013 conducted for

\ '1

--· ·:---'"· """t--" -···j--­

...... 1--·-·.

l'i VAR.IA-no-.V oF DE>VSIT'-f OH ,...,.E c i'\{..16~M'\o-N ijL&C.K. ,s ~r:c:owo TIM(

···!· .•.

:· --

91 >fl; 014 :I»}"

Page 26: Final Report Project HR-1013 - Iowapublications.iowa.gov/19872/1/IADOT_hr_1013_Second... · final report for iowa department of transportation research project hr-1013 conducted for

Cores were taken from a cross section at three locations and the

densities compared. The individual densities exhibited a low

correlation with the CMD, but did exhibit a higher correlation of

density trends (Figs. 21, 22 and 23).

Electronic Problems

It is the opinion of the investigators that the electronics of the

second generation CMD are not durable enough for field operation. The

first generation CMD had no electronic malfunctions that prevented

field operation. The only problem attributed to electronic difficulty

of the first generation CMD was randomly occurring spikes on the

density strip chart (Fig. 24).

Fib. J.4

Trace displaying ''Spikes''

The electronics of the second generation as received did not function

properly. The CMD would not read density or air gap. Two switches,

an integrated circuit (that was not readily available) and one week

were necessary to repair the CMD before laboratory evaluation could

begin. There were several times the electron 1·cs lf ma unctioned and had to be repaired before continuing operation.

Page 27: Final Report Project HR-1013 - Iowapublications.iowa.gov/19872/1/IADOT_hr_1013_Second... · final report for iowa department of transportation research project hr-1013 conducted for

-:;) (.) ~

"' .0

c

147.0

146.0

145.0

·~ 144.0 ())

0

143.0

142.0

-- F:lt:r ~ ;1t I -- --· - --- ------ - -CMD - CORE CORRELATION

STATION 184+29 .TRAVERSING LEFT TO RIGHT

l!l

l!l •

• •

! LEGEND ------

1 CMD

I 4" DIA. CORES

r-- -·-· TOP 4" • _TOP2'~~

141.0-+-~~~~--.~~~~~.--~~~~-.-~~~~-..~~~~--..--~~~~..-~~~~-.-~~~~--.~~~~~~~~~~

4'L 6'L 8'L 10'L' ct i 10'R •8'R ,6'R I 4'R

Page 28: Final Report Project HR-1013 - Iowapublications.iowa.gov/19872/1/IADOT_hr_1013_Second... · final report for iowa department of transportation research project hr-1013 conducted for

147.0

146.0

;::: 145.01

.!.

•1 :J (.) -..._ <f>

~

;:;-·;;;

~ 144.01

\ .

143.0

142.0

r:1e:.- iJ.~ -! CMD - CORE CORRELATION STATION 259+50

TRAVERSING RIGHT TO LEFT

I • l!l

/ • •

\LEGEN-0 I !CMD I ' I I 4" DIA. CORES:

l~TOP4;, • ! TOP2~~ . .

141.0-...~~~~--.~~~~~.--~~-~~-.-~~~~-..~~~~~~~~~~-.-~~~~~~~~~~~~~~~~~

16'Li -er_-! 1o·fi, . ___ _ffu 6'R .4'R 4'L ···~

6'L 8'L' - ·-· ·- -

Position on Pavement

Page 29: Final Report Project HR-1013 - Iowapublications.iowa.gov/19872/1/IADOT_hr_1013_Second... · final report for iowa department of transportation research project hr-1013 conducted for

f I&- ;t3

147.0

146.0

145.0

.~

::i (.) ., <fl

.D

"'

v IVI LJ - ""v n i;;; ""v n n L. 1-1'"'\ I I 'V' l'I

STATION 265+50 : TRAVERSING RIGHT TO LEFT I

-------- --~-~-~-~

I LEGEND

, CMD --4" DIA. CORES

. . - ~· --TOP 4'~ e TOP2~~

1144.0i • [!!

143.0

• 142.0

• [!!

141.0 I '· ... . _L _{_ _L -··-- _ _ _ __ __ _ 4'L 6'L \ ' S'L. 10'L \ __ _j er. ' . ! 10'R L_ \ S'R \ • 6'R' I 4'R

.. . ! Position on Pavement \

Page 30: Final Report Project HR-1013 - Iowapublications.iowa.gov/19872/1/IADOT_hr_1013_Second... · final report for iowa department of transportation research project hr-1013 conducted for

The electronics of the second generation CMD are also susceptible to

commercial band radio waves (Fig. 25). During field operation, the

use of a commercial band radio on the paver would disrupt the CMD's

electronics. Improper functioning of the CMD would continue for a

short period after the use of the radio.