The Part List of water filter
▪ 2 Way High Pressure Solenoid Valve-------------------------------------P2
▪ 2 Way Low Pressure Solenoid Valve--------------------------------------P3
▪ 2 Way High Pressure Solenoid Valve-------------------------------------P4
▪ 3 Way Out Changable Solenoid Valve------------------------------------P5
▪ 3 Way Low Pressure Solenoid Valve--------------------------------------P6
▪ Restrictor-------------------------------------------------------------------P7
▪ Regulator------------------------------------------------------------------P8
▪ Dust filter------------------------------------------------------------------P10
▪ Check Valve----------------------------------------------------------------P11
▪ Bulkhead-------------------------------------------------------------------P12
▪ Ball top--------------------------------------------------------------------P13
2
▣ 2 Way High Pressure Solenoid Valve
Model No. 2WHP-TB1-N6N6
Using Control to shut the water flow on and off
Power AC 110V, 220V, DC 12V, 24V
Working pressure Under 10kgf/cm2
Size of In and Out Nipple type 6.4mm, 8.0mm, 9.5mm
Fitting type 6.4mm
3
▣ 2 Way Low Pressure Solenoid Valve
Model No. 2WHP-TB1-N6N6
Using Control to shut the water flow on and off
Power DC 12V, 24V
Working pressure 50cm/H2O
Water flow 200cc/5sec at 20cm/H2O
4
▣ 2 Way High Pressure Solenoid Valve
Model No. 3WHP-TB2-N8N8
Using Control to shut the water flow on and off for 1 input and 2 output
Power AC 110V, 220V, DC 12V, 24V
Working pressure 0.2kgf/cm2 ~ 10kgf/cm2
5
▣ 3 Way Out Changable Solenoid Valve
Model No. 3WHS-T1-N6N6
Using Change the flow way to out1 and out2 by the controlling the bobbin.
Power DC 12V, 24V
Working pressure 0.5kgf/cm2 ~ 3.0kgf/cm2
Water flow over 1.5 liter / min at 3kgf/cm2
6
▣ 3 Way Low Pressure Solenoid Valve Model No 3WLD-TB2-N8N8
Using Control the one input to 2 output at the same time.
Power AC 110V, 220V DC 12V, 24V
Working Pressure 50cm/H2O
7
▣ Restrictor This restrictor controls flow rate of waste water for RO filter.
Model ID(input) OD(output) cc/min
FRD-F6F6-250 1/4” 1/4” 250
FRD-F6F6-350 1/4” 1/4” 350
FRD-F6F6-500 1/4” 1/4” 500
FRD-F6F6-800 1/4” 1/4” 800
8
▣ Regulator
REC-F6N6
Purpose of using
- To make stable and regular water follow pressure
Specification
Using pressure
1. Maximum : 10 kgf / cm2
2. General : 3kgf / cm2
9
Model ID(input) OD(output) L1 L2 L3
REC-N6N6 1/4” 1/4” 38.0 62.0 50.4
REC-N6F6 1/4” 1/4” 38.0 59.6 50.4
REC-F6N6 1/4” 1/4” 38.0 59.6 50.4
REC-F6F6 1/4” 1/4” 38.0 57.2 50.4
REC-N8N8 5/16” 5/16” 38.0 62.0 50.4
REC-N8F8 5/16” 5/16” 38.0 59.6 50.4
REC-F8N8 5/16” 5/16” 38.0 59.6 50.4
REC-F8F8 5/16” 5/16” 38.0 57.2 50.4
10
▣ Dust Filter
This filter removes the dust before ball top.
Mesh inch / 100mesh
Working pressure 0.2kgf/cm2~10kgf/cm2
11
▣ Check Valve
- This valve allows the water to flow through it in only one direction.
- Working pressure : 0.2kgf/cm2~7kgf/cm2
12
▣ BulkHead
13
▣ Ball top
- This valve shut off and one the water service tube by the buoyancy of plastic ball.
- Maximum water pressure 7kgf/cm2
- Flow rate 1.5liter / min (at 3kgf/cm2)