FILLING PATTERN MEASUREMENTS AT ALBA USING TIME CORRELATED ... · Time Correlated Single Photon...

4
ACDIV-2014-03 June, 2014 FILLING PATTERN MEASUREMENTS AT ALBA USING TIME CORRELATED SINGLE PHOTON COUNTING L. Torino and U. Iriso Abstract: At the ALBA synchrotron light source, the filling pattern is measured using a Fast Current Transformer (FCT). Applying a data analysis the filling pattern is measured with a dynamic range in the order of 10 2 , limited by the electronic noise in the device. A new experimental set- up for filling pattern measurements was implemented using the Time Correlated Single Photon Counting. The technique consists in the measurements of the temporal distribution of the produced synchrotron radiation using Electro-Optical devices, from where the filling pattern is inferred. Two different photomultipliers are used to perform the measurement and results are compared. A further comparison between results from the photomultipliers and the FCT is performed to verify the accuracy of the results. Accelerator Division Alba Synchrotron Light Source Ctra. BP 1413 Km. 3,3 08290 Cerdanyola del Valles, Spain

Transcript of FILLING PATTERN MEASUREMENTS AT ALBA USING TIME CORRELATED ... · Time Correlated Single Photon...

Page 1: FILLING PATTERN MEASUREMENTS AT ALBA USING TIME CORRELATED ... · Time Correlated Single Photon Counting. The technique consists in the measurements of the temporal distribution of

ACDIV-2014-03

June, 2014

FILLING PATTERN MEASUREMENTS AT ALBA USING TIME

CORRELATED SINGLE PHOTON COUNTING

L. Torino and U. Iriso

Abstract: At the ALBA synchrotron light source, the filling pattern is measured using a Fast Current Transformer (FCT). Applying a data analysis the filling pattern is measured with a dynamic range in the order of 102, limited by the electronic noise in the device. A new experimental set-up for filling pattern measurements was implemented using the Time Correlated Single Photon Counting. The technique consists in the measurements of the temporal distribution of the produced synchrotron radiation using Electro-Optical devices, from where the filling pattern is inferred. Two different photomultipliers are used to perform the measurement and results are compared. A further comparison between results from the photomultipliers and the FCT is performed to verify the accuracy of the results.

Accelerator Division Alba Synchrotron Light Source

Ctra. BP 1413 Km. 3,3 08290 Cerdanyola del Valles, Spain