Filament & Heater Repair A9 - Irida Ibérica · 2013. 1. 24. · Thermo* OWA, 3200, 5100 Filament...
Transcript of Filament & Heater Repair A9 - Irida Ibérica · 2013. 1. 24. · Thermo* OWA, 3200, 5100 Filament...
-
A9Filament & Heater Repair
M ost mass spectrometer filaments and heaters can berepaired and restored to a like-new condition byproper cleaning methods and by the replacement ofthe filament ribbon or wire and heater coils. Scientific lnstrumentServices, Inc.™ repairs all of the filaments shown in the followingpages plus many others not shown or listed in the tables.
Filament and Heater RepairsWe take pride in our workmanship and con-
stantly strive to improve the quality and per-formance of our repaired filaments. We appreci-ate any feedback and suggestions from our customers. Scientific Instrument Services,Inc.™ has been repairing filaments for all mod-els of mass spectrometers commercially for 30years. In that time we have rebuilt tens of thou-sands of filaments. We are constantly improvingour techniques and adding new equipment, ten-sioning and alignment jigs, and methodology toour shops to provide the best possible filamentrepair. In the following pages the descriptions ofthe repair services we provide on various man-ufacturers’ filaments are described. See ourweb site for complete details.
NEW FlLAMENTS: Using our experience inrepairing different types of mass spectrometer filaments,Scientific lnstrument Services, Inc.™ has redesigned many ofthese filaments to provide filaments that are less expensive,more durable, longer lasting, and are easier to rebuild and clean.These filaments are fully described in the section of this catalogimmediately following the filament repairs.
OTHER FILAMENT REPAIRS: In addition to the filamentsdescribed herein, we can repair many other filaments. If your fil-ament is not described in this catalog, give us a call. In thesecases, any information that you can provide such as a descriptionof the filament design or construction, composition and size of thefilament material, or drawings of the filament would be greatlyappreciated. If possible, send us a filament for repair with at leasta small piece of the original filament material intact. We will needsome of this filament material to determine its dimensions andcomposition. Normal delivery on these special requests is 3 to 4weeks when done for the first time. Subsequent deliveries will be2 to 3 weeks.
NEW - YTTRIA AND THORIA COATED FILAMENTS: SIS cannow coat your repaired filament with either Thoria or Yttria.Several manufacturers have used these filaments with anticipat-ed increase in filament emission at lower filament temperaturesresulting in longer filament life. If you would like to experimentwith these styles of filaments in your mass spectrometers, we cancoat most styles of filaments. An application note on Yttria andThoria coated filaments is on our web site at:http://www.sisweb.com/reference/applnote/app-92.htm
Return Authorization Numbers Are NotRequired
EMERGENCYREP AIRS: Emergency repairs can be completed and shipped out within 24 hours of receipt of yourparts and purchase order. Parts can be shipped via FederalExpress, if required. Rush charges may be incurred.
SHIPPING INSTRUCTIONS: Most glass parts and ceramic insulators are very fragile and are easily damaged during shipment. Therefore, please package all filaments carefully toavoid damage during shipment. We recommend that you package the filaments personally. Filaments should be packagedin a box at least 6 inches square using packing peanuts or bubble pack as cushioning. We recommend shipping by UPS orFederal Express for best handling.
PRICES FOR FILAMENT REPAIRS: All filament and heaterprices are listed in the table above. Scientific Instrument Servicescontinues to offer superior quality repairs at low prices. We havecontinued to expand our shop facilities and strive to improve ourmethods, techniques and materials. For the best prices, ship filaments to us in larger lots. This reduces the cost of handlingand processing orders, thereby allowing us to pass the savingson to you. Filaments and heaters from various manufacturers canbe combined to obtain the best prices. Other repairs of parts forthe various mass spectrometers are described in the sections ofthis catalog on the Thermo, Agilent Technologies, and Varianparts and service.
Repair of Mass Spectrometer Filaments & Heaters
• Inspected upon arrival at our facilities• Filaments are thoroughly cleaned• Damaged or broken parts repaired or
replaced• New filament aligned & spotwelded in
place• This is not an exchange program. Your
filaments are repaired and returned to you.
FILAMENT AND HEATER REPAIR PRICES
Part No. Description Quantity Price
FILREP Standard Filament Repair 1
FILREPY† Filament Repair with Yttria Coating 1
FILREPT*† Filament Repair with Thoria Coating 1
FILREPX X-Ray Generator Filaments for 1Rigaku and Siemens
FILREP44S Heater Repair for MAT 44S 1
FILREPQ Perkin Elmer Q-Mass Filament Repair 1
*Note: Thoria coated filaments must be handled carefully, since thorium oxide is considered to be hazardous. Do not inhale or ingest the dust or fumes from these filaments. Wash hands thoroughly after handling these filaments.
When “Thermo” is indicated, it is intended to imply “Thermo Fisher Scientific Corp”
-
Filament & Heater RepairA10
The Agilent Technologies filaments can be repaired. We will completelyclean the assembly and replace the rhenium filament wire or coil.
Agilent Technologies FILAMENT REPAIR
NEW Agilent Technologies FILAMENTS
HPF4 - 5970 Filament
Ignitor Assembly Filament
HPF2 - 5989 Engine Filament
HPF3 FilamentHPF1 Filament
5972/5973 Filament
5975 Filament
5971/GCD Filament
5973 CI Filament
For New Filaments, See Pg.A21
Filaments are aligned andspotwelded into place
The low cost of these filaments makesthem not repairable. They are only avail-able as new replacement filaments. SeeAgilent section for pricing. For other newAgilent filaments see our new filamentsection of this catalog.(A21-A22)
-
A11Filament & Heater Repair
3200 Heater
8200 DCI Filament
HT5100 Heater
4500/TSQ Heater
Varian 1200 Filament
Varian 0393161001 Filament
DEP FilamentSSQ 7000 / DSQ/GCQ Filament
SIS 3200 Filament
4000 Filament(40004-60070)
4500, 4600 Filament(40005-60140)
8200 Filament(44691)
8200 DCI FilamentDEP FilamentGCQ FilamentDSQ Filament
OWA®, 5100 Filament(30004-60020)
TSQ70 FilamentTSQ46 FilamentTSQ700 Filament
INCOS 50B, 500, XL FilamentIon Trap, ITMS, ITS40 Filament
Magnum Filament SSQ 7000 Filament
Varian 1200 FilamentVarian 0393161001 Filament
1015 Filament(30004-60020)1020 Filament (30004-60020)
3000, 3100 Filament(30004-60020)
3000, 3100 Heater(01554-20180)
3200, 3300 Filament(30004-60020)
3200, 3300 Heater(01554-20180)
Thermo Filaments Repaired
OWA® is a registered trademark of Thermo Corp.
SIS 5100 Ceramic Filament
Thermo*
OWA, 3200, 5100 Filament
Thermo 4000 Filament
Ion Trap Magnum Filament
4500, TSQ Filament
Ion Trap Old Dual Filament
Incos 50 B Filament
S.I.S. 4000 Filament MAT 4000 Lens HeaterREP43
MAT 4000 Lens HeaterREP44
MAT 95 Heater
TSQ70 Ion Source Heater
When “Thermo” is indicated, it isintended to imply “Thermo FisherScientific Corp.”
-
Filament & Heater RepairA12
MAT 271 Filament
MAT CH7 FilamentMAT 8200 Filament
MAT 251 Filament- RibbonMAT 252 Filament- Wire
MAT Delta S Filament
MAT 250 Filament MAT311A Filament- Ribbon
MAT CH5 HeaterMAT 900 Heater
MAT 90 HeaterMAT 44S Heater*
MAT 112S Heater MAT CH7 HeaterMAT 311A Heater
Part No. PriceFILREP44S
*MAT 44S Heater Repair
44 Filament (18597)44S Heater
111 Filament (91975)112 Filament (16839)
112 Collector112S Filament (44691) 112S Heater (44692)
212, 271 Filament (18597)212S Filament (91999)
250/251/252 Filament, Tungsten 311 Filament (91962)
311A Filament (18597) 311A Heater
312 Filament (18597)711 Filament (91999
731 Filament 8200 Filament (44691)
CH4 Filament (90099) & (91102) CH4 Heater
CH4 Pressure Measuring CH5 Filament (491555)
CH5 Pressure Measuring (491327)
CH5, CH7, 44 HeatersCH7 Filament (491490)
Delta S FilamentElectron Gun 981-1215, 981-2454MAT 90, 900 Filament & Heater
MAT 95S FilamentGD150 FilamentEM600 FilamentFTMS Filament
FILAMENTS REPAIRED
MAT 95S Filament
Varian GD150 Filament FTMS Filament
MAT 90 Filament
Varian EM600 Filament
Thermo/MAT*
When “Thermo” is indicated, it is intended to imply “Thermo Fisher Scientific Corp.”
-
VG MM 602 Filament
VG MD800 TrapVG MD800 Filament
A13Filament & Heater Repair
VG DCI Filament VG Autospec DCI Filament
VG 70-70, 5 Coil Filament VG GCT FilamentVG 70-70, 3 Coil Filament VG Autospec, GCT, &Quattro Micro Filament
VG 70-70, Ribbon Filament
VG RGA Filament VG SK200 FilamentVG 5400 Filament
VG Platform Filament
VG Platform DCI Filament
VG MM3000 FilamentVG Nobel Gas Filament
VG Ion Gauge Fil.
Waters GCT Probe Tip Fil. AG6 Filament
Waters MassDetector Fil.
VG/FISONS/MICROMASS/WATERS
SHIMADZUQP5000 Filament QP2000 HeaterQP2000 FilamentQP1000 Filament QP2010 FilamentPS5000 Filament
-
Filament & Heater RepairA14
Kratos MS 30 Filament
Kratos 84-199R Ion GaugeFilament
Kratos ESCA Filament
Kratos MS 25 Trap
Kratos Ion Gun Filament
Kratos XSAM 800 Filament
Kratos MS 80 Trap
Kratos Ion Gauge Filament
Kratos MS 25 Filament
Kratos MS 50 Filament
Kratos MS 80 Filament
Kratos MS 50 Trap
Kratos MS 9 Filament
Kratos MS 80 DCI Filament
Kratos MS 10/20 Filament
Kratos Concept Filament
A ll types of filaments and trapsfor the AEI/Kratos instru-ments can be repaired asdescribed in this catalog. The ceramicparts of filaments such as the MS80 arethoroughly cleaned by sandblasting toremove all carbon residues and thenrepaired with high purity rhenium wire.In addition, S.I.S.™ manufactures newfilaments and traps for the MS80 instru-ment as described in subsequentpages.
Concept FilamentESCA Dual FilamentHV Ion GaugeFilament Ion Gun FilamentMS 9 FilamentMS 10 Filament MS 12 Filament MS 20 Filament MS 25Q FilamentMS 25Q Trap MS
MS 30 Filament (58-452)MS 50 Filament (58-009)MS 50 Trap MS 80 Filament (58-825)MS 80 Trap (58-826)MS 80 DCI
MS 902 Filament XSAM 800 Fil84-199R Ion GaugeFilamentX-RayMonochrometerFilament
FILAMENTS REPAIRED
KRATOS
Kratos X-RayMonochrometer Fil
-
A15Filament & Heater Repair
PERKIN ELMER/HITACHI MGA-1100 Filament Turbomass Rhenium Fil. Turbomass Tungsten Fil.Q-Mass Source
RMU-2 Filament
P.E.1600 Filament
P.E. Filament
DP 21-620 FilamentDP 21-490 Filament
Extrel Filament041-1 Filament
DP 21-490 Heater DP 21-620 HeaterDP 21-615 Filament
DP 21-110 FilamentDP 21-102 Filament DP 21-102 Heater DP 21-120A FilamentDP 21-103 Filament
RMU-6 Heater
ELQ400 Filament Benchmark Filament
RMU-6 Filament
Questar 4 Filament
Part No. Description PriceFILREPQ Q-Mass Source*
EXTREL
DUPONT/CEC
-
Filament & Heater RepairA16
OTHER FILAMENT REPAIRS In addition to the filaments described on the previous pages, S.I.S.™ can repair filaments for many other mass spectrometers. If your
filament is not listed here, give us a call and we will discuss its repair.
9225 FilamentFR571 Filament
JEOLGC MATEDX 303 / SX102A GC MATE II Canon FAB
AIRCO ALCATEL AMD
GOW-MAC
Intecra FilamentASM 110 Turbo CL Intecra HeaterIntecra DCI Filament
AMATEK BALZER
EAIQuadrupole Filament
HIDENRGA Filament
LC-50 Leak Detector Fil.
MS CubeQMG 311 RGA FilamentClosed Source RGARGA Filament
Leak Detector Filament
CONSOLIDATED ELECTRONICS ENRAF NONIUS
-
A17Filament & Heater Repair
QX2000 Filament
Leak Detector Filament Hapsite Filament
CIS Filament EA11 Filament
JEOLCanon GunDCI FilamentHeater
LEYBOLD INFICON LKB9000 Filament
9000 Heater
2091 Filament
MILTON ROYPro Spec 2000
Datum “K” Filament
IQ-200 RGA Fil
MARQUETTE MATTSONGalaxy 620 FTIR411405-003 Fil.
-
Filament & Heater RepairA18
NUCLIDEPHYSICALELECTRONICS RIBER SARA
SPECTRUM TREMETRICSCIS Filament
ULVAC
UTI VACUUMETRICS VEECO
RGA Filament
SPECTROMASSVIAS RGA Filament
100 Quadrupole
Turbo Filament
Kratos XSAM 800 FilamentKratos ESCA FilamentRGA Filament RGA Filament
R10-10 Filament
Kratos MS 25 Filament
9225 Filament 850/950ES Filament
Automass Fil.
Hall Reactor Heater
Ion Gun Filament
DCI FilamentNERMAG NICOLET
1000 Filament
MAAS 6-60 Filament
-
D4892V3. EP1 Filament CN4892S2 Filament
CN4892T1 Filament
Filaments for the x-ray generators manufactured by Rigaku, Siemens and Elliot can be repaired by Scientific InstrumentServices™. These instruments, which are used in crystallography, utilize coiled tungsten filaments. S.I.S.™ can repair these fila-ments at a large savings over the cost of replacement filaments from the manufacturer. The repaired filaments have demon-strated performances at least equal to the original filaments supplied by the manufacturers. Various shapes and sizes of coils are avail-able, a few of which are shown on the heater coil page.
CN4892V1 Filament CN4892V2 Filament
CN4894B106 Filament TXRF (B) Filament AP6 Filament
CN4892X2 Filament CN4893C1 Filament CN4894A115 FilamentCN4893D1 Filament
CN4894A111 FilamentCN4893B1 Filament
FILAMENT REPAIR PRICES X-Ray Generator Filaments - Part No. FILREPX
for Rigaku and Siemens1 ..........................................
6 or more ........................5% discount
Siemens 12 coil Filament Siemens 18 coil Filament Siemens 22 coil Vertical FilamentSiemens 22 coil FilamentSIEMENS/BRUKER
A19X-Ray Generator Filament & Heater Repair
RIGAKU
-
New Mass Spec Filaments by S.I.S.™A20
VG Filaments (also Vestec)
Part No. Description Price / ea.VGFAB Single Slanted Probe Tip
10 or moreVGFB2 Single Straight Probe Tip
10 or moreVGFB3 Double Probe Tip
10 or more
Part No. Description Price / ea.VG90 Vespel DCI Probe Tip for
VG TRIO 1000, 2000VG91 DCI Probe Tip filament for VG TRIO 1000VG92 DCI Probe Tip filament for VG TRIO 2000FILREP Repair of SIS designed DCI Tip Filament
VG-FAB Probe Tips Scientific Instrument Services manufactures VG-FAB probe
tips. These new probe tips are similar in construction to the orig-inal FAB tips but with a slightly larger and stronger ceramic base.This results in a much more durable probe tip.
Three styles are available: the slanted design used on themajority of instruments (VG-FAB), the new straight design, (VG-FB2), and the dual design (VG-FB3) used on some of the newerinstruments.
S.I.S. has redesigned the DCI Probe Tip for VG TRIO 1000and 2000 instruments. The new design incorporates a VespelDCI Probe Tip Base which plugs into the tip of your existingprobe. Then the replaceable Probe Tip Filaments are pluggedinto this new Vespel Probe Tip Base. Once the Vespel Probe TipBase is purchased, the cost of repairing or replacing the probefilaments is much less than those available from the manufactur-er. This new DCI probe tip was designed for and tested by sev-eral of our customers. The DCI filaments performed the same asthose originally used but the replacement cost is much less.
* Custom styles available on special request. Other coil sizes and shapes available on request.
Replaceable Probe Tip FilamentSlanted VGFAB Straight VGFB2 Dual VGFB3Vespel Probe
Tip Base
Scientific Instrument Services™ man-
ufactures replacements for the VGfilaments which are similar in
design to the original. This new design is adirect retrofit and incorporates a glass frit tohold the posts in place. Seven styles areavailable: the standard five coil design(#VGF-1 ) used on most instruments, thethree coil design (#VGF-2) used in high sen-sitivity applications, the ribbon design(#VGF3), the Autospec design (VGF4), thefilament used on the MD800 (VGF5), thePlatform filament (VGF6) and the MicromassGCT filament (VGF7).Filament Repairs - see page A13
VG Autospec, GCT,Quattro Micro
VGF4
VGMD800VGF5
VG PlatformVGF6
VG70703 CoilVGF2
VG7070, Quattro 5Coil
VGF1
VG70705 andVestec Ribbon
VGF3
Price ea.Part No. Description Price ea. 6 or moreVGF1 SIS VG-7070 filament, 5 coil VGF2 SIS VG 7070 filament, 3 coil VGF3 SIS VG 7070 and Vestec filament, ribbonVGF4 SIS VG Autospec, GCT,
Quattro Micro filamentVGF5 SIS VG MD800 filamentVGF6 SIS VG PlatformVGF7 SIS VG Micromass GCT filament
VG Micromass GCTVGF7
New DCI Probe Tip Design for theVG TRIO Mass Spectrometers
-
A21New Mass Spec Filaments by S.I.S.™
Scientific Instrument Services™ manufactures the
filaments for the Agilent Technologies MSD seriesmass spectrometer (Agilent Models 5992, 5992A,
5992B, 5993, 5993B, 5995, 5970, 5970A, etc.)* These fil-aments are exact retrofits for the original AgilentTechnologies filaments (#05990-60084). Strict quality con-trol is adhered to when manufacturing these filaments.Distance between filament posts is accurate to within0.001". Each rhenium wire filament is accurately tensionedand aligned on an Agilent source block. The filament wireis accurately positioned over the ion source slit to assureoptimum performance.
Agilent Technologies 5989 Filaments S.I.S. manufactures the strap or band style filaments for the Agilent Technologies 5989
and other 5980 series mass spectrometers (Agilent #05985-60179). The rhenium filament wire is accurately positioned, tensioned, and spot welded to the metal strap. Themetal strap contains the pre-punched holes for easy installation.
Agilent Technologies Wire Filaments and Support Wires
S.I.S. manufactures both the rhenium filament wires with looped ends (Agilent #05980-60089) and the tungsten support wires on hooks (Agilent #05980-20396)for the Agilent Technologies 5980 series mass spectrometers.
MSD® is a registered trademark of Agilent Technologies Co.
Part No. Agilent Part # Description Price/ea. HPF4 (Agilent #05990-60084) SIS-Agilent 5992/5970 Filament
6 or more
Part No. Agilent Part # Description Price/ea. HPF2 (Agilent #05985-60179) Agilent Strap Filament
6 or more
Part No. Agilent Part # Description Price/ea. HPF1 (Agilent #05980-60089) Looped Filament Wire
6 or moreHPF3 (Agilent #05980-20396) Filament Support Wire
6 or more
Filament alignment on source alignment block
HPF3
HPF1
HPF-2
HPF4Filament
Every filament is precisionaligned for optimum performance.
Filaments for Agilent Technologies 5970 MSD®and 599X Mass Spectrometers
-
New Mass Spec Filaments by AgilentA22
Filaments for Agilent Technologies 5971 and GCD Mass Spectrometers
Filaments for Agilent 5972, 5973, and 5975 Inert Mass Spectrometers
Part No. Description Price/ea. 05971-60140 Agilent GCD/5971 Filament
Part No. Description Price/ea. G2590-60053 Agilent 5975/5973 Inert Filament
These Agilent original filaments are now available from S.I.S.™ These filaments are manufactured by Agilent Technologies.
These Agilent original filaments are now available from S.I.S. These filaments are manufactured by Agilent Technologies.
These Agilent original filaments are now available from S.I.S. These filaments are manufactured by Agilent Technologies.
05971-60140
G1099-80053
Filament Repairs - See Page A10.
Filament Repairs - See Page A10.
Filament Repairs - See Page A10.
G2590-60053
CI Filaments for Agilent 5972 and Agilent 5973 Mass Spectrometers
Part No. Description Price/pk. G1099-80053 Agilent 5973 CI Filament, 2 pk
-
A23New Mass Spec Filaments
Thermo DEP Filaments Direct Exposure Probe filaments for use on the Thermo 4000 and 4500 mass specs are available from Scientific Instrument Services™.
These filaments are direct retrofits for the original plug-in filament. Standard sample loop is 0.016" diameter.S.I.S. also offers a variety of other filament designs for use on the Thermo probe. FINDEP1 has a larger loop diameter of .031". FIND-
EP2 is a glass encapsulated loop. This provides a metal-free surface for your samples. FINDEP3 utilizes a filament ribbon for easy sam-ple loading. Give us a call if you would like to try something different FINDEP7000 is for use on the Thermo TSQ7000 mass spec.
The Thermo TRACE™ FilamentsFilaments for the Thermo TRACE mass spec is available from SIS. This is a direct replacement
for the one supplied by Thermo.
Part No. Thermo No. Description Price ea.FF50B 55000-60080 Incos 50B Filament
6 or more
New Thermo Incos™ FilamentThe Incos filament is available from S.I.S and consists of a ceramic body press with connectors for inserting the 0.040" diameter lead
wires. For Incos 50B, 500 and XL.
Part No. Thermo No. Description Price ea. FIN-DEP 40060-98006 SIS DEP Filament
6 or moreFIN-DEP1 Large Loop DEP FilamentFIN-DEP2 Glass Encapsulated FilamentFIN-DEP3 Ribbon FilamentFINDEP7000 DEP Filament for 7000
Part No. Description Price ea. VGF5 SIS TRACE Filament
FF50B Filament
FINDEP
VGF5 Filament
FINDEP 2
FINDEP 3
Incos™ is a registered trademark of Thermo
The plug-in style filaments for the Thermo and Varian Ion Trap instruments are available from S.I.S.™ These are direct replace-
ments for those supplied by Thermo, Varian, Perkin-Elmer, Teledyne and Hitachi. S.I.S. also repairs these filaments as well asthe original filaments which were mounted on a flange.
Part No. Thermo No. Description Price ea. FF700 94011-60090 ITD Filament
6 or moreIon Trap® is a registered trademark of Thermo.
Part No. Thermo No. Description Price ea. FF4500 40005-60140 SIS 4500 Filament
6 or more
FF700 Filament
FF4500 Filament
Thermo Ion Trap®, Varian Saturn, Teledyne 3DQ™and Hitachi Filaments
- Filament Repairs - See Page A11.
The Thermo SSQ™/TSQ™, 70 and 700, 4500 FilamentsThis new design incorporates stronger, round filament posts, which do not bend, instead of the straps used by Thermo.
Bending would cause the filament to sag, lose sensitivity, and short out against the shield. In addition, we have lowered the shield approx-imately 0.25 mm. This also delays a sagging filament from shorting out. (Thermo #40005-60140)
When “Thermo” is indicated, it is intended to imply “Thermo Fisher Scientific Corp.”
-
New Mass Spec FilamentsA24
The metal filament shown on the right is a filament similar to the original Thermo filament for those users who prefer this style filament. However, sev-eral design improvements have been made for better performance. The filamentshield is constructed from a heavier gauge stainless steel material and is much stronger. Thefilament posts have been shortened and are constructed of a heavier gauge metal to help elim-inate filament sagging.
Ceramic Body Filament for Thermo 3000 and 3200 Series MassSpectrometer
These ceramic body filaments were designed to eliminate many of the problems associated with the Thermo metal type filaments. Our new design is strong and durable. The short metal posts hold the filament wire straight, while tension is maintained to minimizing sagging. The ceramic body eliminates shorting of the filament to the source. The filaments come complete with silver wire leadsand stainless steel mounting screws. Connections to instrument lead wires can be made with the connector listed below (requires two connectors).
Part No. Thermo No. Description Price ea.SF5100 30004-60020 Stainless body 3000 series
Filaments6 or more
*For Incos 50 only. Does not fit Incos 50B, 500 or XL.
Part No. Description Price ea.FF3200 SIS Thermo 3200/OWA Filament
6 or more SC1 Stainless Steel Connector
Thermo** 3000, 5100, 1020, OWA® and Incos™* Stainless Steel BodyFilaments Redesigned and Manufactured by S.I.S.
SF5100 Filament
FF 3200Ceramic
BodyFilament
OWA® is a registered trademark of Thermo Corp.
SC1 Stainless Steel
Connector
The posts protrude out of the middle of the filament. There is no metal in the back to short against the magnet. Also, there is no metalon the ends, which insulates the filament from shorting out in these areas as well. The 0.032" diameter leads can be cut to the desiredlength, depending on the configuration of your instrument.
These filaments can be connected to your leads with two push-on connectors (SlS Part# B11288-2) or stainless steel connectors (SISPart #SCI)
*For Incos 50 only. Does not fit Incos 50B, 500 or XL.
Thermo 5100 Ceramic Body Filament
Part No. Description Price ea.FF50 Incos 50 Filament
6 or moreSC1 Stainless Steel Connector
This filament has been specifically designed for the Thermo 5100 heated source. The 0.032" diameter filament leads protrudeout of the side to clear the source block and permit attachment with a connector (2 connectors required). Filament leads can becut to desired length before attachment of connecting leads. This ceramic body filament will eliminate shorting out problemscommon with the metal filaments and will provide improved performance over the original metal style filaments.
Incos 50* Ceramic Body Filament
Part No. Description Price ea.FF51 5100 Ceramic Body Filaments
6 or moreSC1 Stainless Steel Connector
FF51 Filament
FF50 Filament
** When “Thermo” is indicated, it is intended to imply “Thermo Fisher Scientific Corp.”
-
A25New Mass Spec Filaments
Extrel FilamentS.I.S.™ manufactures filaments for the Extrel mass spectrometer. The filament press
has been redesigned out of a high purity alumina. The five coil tungsten style filaments are precisely aligned for optimum performance..
Nermag DCI Filaments New DCI filaments for the Nermag mass spectrometers are in stock at S.I.S. These
fiIaments are constructed with a ceramic base and solid posts for sturdy performance andare ready for installation. S.I.S. also sells just the filament coils for those who wish torebuild or manufacture their own filaments.
Part No. Description Price ea.NFI1 Nermag DCI Filament
6 or moreHC8 Replacement Nermag DCI Coils
10 or more
Part No. Description Price ea. EX100 Extrel Filament
6 or more
Nermag Automass FilamentsNew filaments for the Nermag Automass mass spectrometer are in stock at S.I.S.
These filaments are direct replacements for the Nermag Originals. Also in stock are the filaments for the Unicam/Nermag updated Automass source (NFI3).
Part No. Description Price ea.NFI2 Nermag Automass Filament
6 or moreNFI3 Unicam/Nermag Automass Filament
6 or more
EX100
NFI1
NFI2
Kratos MS-80 DCI Filaments New Kratos DCI Filaments are available from S.I.S. These
are retrofits for the original filaments from Kratos. These sturdy filaments come complete with coil in place for immediate use.
Kratos MS-80 Filaments and Traps
S.I.S. manufactures filaments and traps for the Kratos MS-80 with a design and construction similar to the originals.S.I.S. also manufactures these parts using Vespel insteadof MACOR. This provides a more durable filament base at areduced cost.
Part No. Kratos No. Description Price ea.KMS1 58-825 SIS Kratos MS-80 filament KMS2 58-826 SIS Kratos MS-80 trap KMS4 Vespel MS80 TrapKMS5 Vespel MS80 Filament
KMS1 KMS2
Part No. Description Price ea.KMS3 Kratos DCI Filament
KMS3