Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...
Transcript of Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...
![Page 1: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/1.jpg)
Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint Samplers for Detection of Metals in Sediment Pore Water, Ashland and Clinton, Massachusetts, 2003
By Marc J. Zimmerman, Don A. Vroblesky, Kimberly W. Campo, Andrew J. Massey, and Walter Scheible
In cooperation with the U.S. Environmental Protection Agency Measurement and Monitoring for the 21st Century Initiative
Scientific Investigations Report 2005-5155
U.S. Department of the InteriorU.S. Geological Survey
![Page 2: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/2.jpg)
U.S. Department of the InteriorGale A. Norton, Secretary
U.S. Geological SurveyP. Patrick Leahy, Acting Director
U.S. Geological Survey, Reston, Virginia: 2005
For sale by U.S. Geological Survey, Information Services Box 25286, Denver Federal Center Denver, CO 80225
For more information about the USGS and its products: Telephone: 1-888-ASK-USGS World Wide Web: http://www.usgs.gov/
Any use of trade, product, or firm names in this publication is for descriptive purposes only and does not imply endorsement by the U.S. Government.
Suggested citation:Zimmerman, M.J., Vroblesky, D.A., Campo, K.W., Massey, A.J., and Scheible, Walter, 2005, Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint Samplers for Detection of Metals in Sediment Pore Water, Ashland and Clinton, Massachusetts, 2003: U.S. Geological Survey Scientific Investigations Report 2005-5155, 51 p.
![Page 3: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/3.jpg)
iii
Contents
Abstract ……………………………………………………………………………………… 1Introduction …………………………………………………………………………………… 2Study Areas …………………………………………………………………………………… 3Study Design ………………………………………………………………………………… 6Preliminary Laboratory Testing and Analysis ………………………………………………… 6
Sampler Equilibration …………………………………………………………………… 6Equipment Blanks ……………………………………………………………………… 7
Sediment Pore Water Field-Sampling Techniques …………………………………………… 11Nylon-Screen Diffusion Samplers ……………………………………………………… 11Pushpoint Samplers ……………………………………………………………………… 12Site Selections …………………………………………………………………………… 13Quality-Control Sampling and Results …………………………………………………… 13
Comparison of Metal Concentrations in Pore Water Collected with Nylon-Screen Diffusion and Pushpoint Samplers …………………………………………………… 15
Time Series of Nylon-Screen Diffusion Sampler Data …………………………………… 16Comparison of all Nylon-Screen Diffusion Samples and Pushpoint Samples by Site …… 17
Summary and Conclusions …………………………………………………………………… 18Acknowledgments …………………………………………………………………………… 19References Cited ……………………………………………………………………………… 19
Figures 1–3. Photographs showing: 1. The 125-milliliter nylon-screen diffusion sampler ……………………………… 2 2. PVC shovel for inserting nylon-screen diffusion sampler into sediments ……… 3 3. A, The 91-centimeter PushPoint Extreme Sampler; and B, Detail of tip ……… 3 4. Map showing locations of study areas: A, Mill Pond, Sudbury River, Ashland,
Massachusetts; and B, Rigby Brook, Clinton, Massachusetts ……………………… 4 5, 6. Graphs showing: 5. Comparisons of A, concentrations; and B, relative percent differences
between water samples obtained from the test container and from nylon-screen diffusion samplers after 4 days of equilibration ………………… 7
6. Laboratory quality-control data for A, barium; and B, zinc for components of sampling equipment ………………………………………………………… 10
7. Photograph showing collection of a field sample from nylon-screen diffusion sampler by using syringe, filter, and hypodermic …………………………………… 12
8. Schematic showing distribution of sampling sites at the A, Nyanza study area, Ashland; and B, Rigby Brook study area, Clinton …………………………………… 14
![Page 4: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/4.jpg)
iv
9, 10. Boxplots showing: 9. Selected metals concentrations in 25 samples collected with nylon-
screen diffusion samplers and 35 samples collected with pushpoint samplers at the Nyanza study area, Ashland, May 2003 ……………………… 16
10. Selected metals concentrations in 24 samples collected with nylon- screen diffusion samplers and 34 samples collected with pushpoint samplers at the Rigby Brook study area, Clinton, May to June 2003 ………… 17
11–14. Graphs showing: 11. Time series data for A, aluminum; B, arsenic; C, barium; D, cobalt; E, iron;
F, manganese; and G, zinc at the Nyanza study area, Ashland, May 2003 …… 21 12. Time series data for A, aluminum; B, arsenic; C, barium; D, cobalt; E, iron;
F, manganese; and G, zinc at the Rigby Brook study area, Clinton, May to June 2003 ……………………………………………………………………… 25
13. Results for final round of sampling with nylon-screen diffusion samplers and pushpoint samplers for A, aluminum; B, barium; C, cobalt; D, iron; E, manganese; and F, zinc at all Nyanza study-area sampling sites, Ashland, May 2003 …………………………………………………………… 29
14. Results for final round of sampling with nylon-screen diffusion samplers and pushpoint samplers for A, aluminum; B, barium; C, cobalt; D, iron; E, manganese; and F, zinc at all Rigby Brook study-area sampling sites, Clinton, June 2003 ……………………………………………………………… 35
Tables 1. Concentrations of solutes in water collected from bucket by using peristaltic
pump and from 125-micron-mesh nylon-screen diffusion samplers immersed in the bucket, November 2000 ……………………………………………………… 6
2. Concentrations of metals detected during quality-control testing of the sampling process …………………………………………………………………… 8
3. Target analytes, their project action limits, and minimum reporting levels used for this study ………………………………………………………………………… 9
4. Medians of paired relative percent-difference values for individual metals in nylon-screen diffusion samples and pushpoint samples collected at the Nyanza study area, Ashland, Massachusetts, and at the Rigby Brook study area, Clinton, Massachusetts …………………………………………………………… 15
5. Concentrations of metals detected in ground water 20 cm below sediment surface at selected well locations for the Nyanza Superfund Site, Ashland, June 2001 …………………………………………………………………………… 18
6. Concentrations of metals in quality-control samples during field studies at the Nyanza study area, Ashland, and the Rigby Brook study area, Clinton ………… 41
7. Concentrations of metals detected in samples from the Nyanza study area, Ashland …………………………………………………………………………… 46
8. Concentrations of metals detected in samples from Rigby Brook study area, Clinton ……………………………………………………………………………… 49
![Page 5: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/5.jpg)
v
Conversion Factors, Datum, and Abbreviations
Multiply By To obtain
centimeter (cm) 0.3937 inch (in.)
liter (L) 0.2642 gallon (gal)
meter (m) 1.094 yard (yd)
micron (µ) 0.00003937 inch (in.)
milliliter (mL) 61,020 cubic inch (in3)
millimeter (mm) 0.03937 inch (in.)
Horizontal coordinate information is referenced to the North American Datum of 1983 (NAD 83).
Specific conductance is given in microsiemens per centimeter at 25 degrees Celsius (µS/cm at 25°C).
Concentrations of chemical constituents in water are given either in milligrams per liter (mg/L) or micrograms per liter (µg/L).
Ag silver Al aluminum As arsenic Ba barium Be beryllium Cd cadmium Co cobalt Cr chromium Cu copper Fe iron Hg mercury Mn manganese Mo molybdenum Ni nickel Pb lead Sb antimony V vanadium Zn zinc DO dissolved oxygen ICP-MS inductively coupled plasma—mass spectrometry NSDS nylon-screen diffusion sampler PAL project action limit PPS pushpoint sampler RPD relative percent difference USEPA U.S. Environmental Protection Agency USGS U.S. Geological Survey VOC volatile organic compound
![Page 6: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/6.jpg)
Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint Samplers for Detection of Metals in Sediment Pore Water, Ashland and Clinton, Massachusetts, 2003
By Marc J. Zimmerman1, Don A. Vroblesky2, Kimberly W. Campo1, Andrew J. Massey1, and Walter Scheible3
AbstractEfficient and economical screening methods are needed
to detect and to determine the approximate concentrations of potentially toxic trace-element metals in shallow ground-water-discharge areas (pore water) where the metals may pose threats to aquatic organisms; such areas are likely to be near hazardous-waste sites. Pushpoint and nylon-screen diffusion samplers are two complementary options for use in such environments.
The pushpoint sampler, a simple well point, is easy to insert manually and to use. Only 1 day is required to collect samples. The nylon-screen diffusion sampler is well suited for use in sediments that do not allow a pump to draw water into a pushpoint sampler. In this study, both types of devices were used in sediments suitable for the use of the pushpoint sampler. Sampling with the nylon-screen diffusion sampler requires at least two site visits: one to deploy the samplers in the sediment, and a second to retrieve the samplers and collect the samples after a predetermined equilibration period.
Extensive laboratory quality-control studies, field testing, and laboratory analysis of samples collected at the Nyanza Chemical Waste Dump Superfund site along the Sudbury River in Ashland, Massachusetts, and at a Superfund site-assessment location on Rigby Brook in Clinton, Massachusetts, indicate that these two devices yield com-parable results for most metals and should be effective tools
for pore-water studies. The nylon-screen diffusion samplers equilibrated within 1–2 days in homogeneous, controlled conditions in the laboratory. Nylon-screen diffusion samplers that were not purged of dissolved oxygen prior to deployment yielded results similar to those that were purged. Further test-ing of the nylon-screen diffusion samplers in homogeneous media would help to resolve any ambiguities about the data variability from the field studies.
Comparison of data from replicate samples taken in both study areas shows that even samples taken from sites within a half-meter radius of one another have distinct differ-ences in pore-water trace-element concentrations. Sequential replicate samples collected with the pushpoint sampler yield consistent results; moving the pushpoint sampler even 5 to 10 centimeters, however, generally produces a second set of data that differs enough from the first set of data to indicate a heterogeneous environment. High concentration biases for barium and zinc in laboratory and field samples collected with nylon-screen diffusion samplers, however, may make their use inappropriate for studies of these metals.
Analyzing samples with high iron concentrations required sample dilution by factors of 2 or 10. Because these dilutions caused increases in the reporting levels by the same proportion, a substantial fraction of the data was censored. The results from undiluted samples, however, indicate that both devices should be useful for sampling ground water with metal concentrations close to reporting limits.
1U.S. Geological Survey, Northborough, Massachusetts.2U.S. Geological Survey, Columbia, South Carolina.3Columbia Analytical Services, Rochester, New York.
Abstract 1
![Page 7: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/7.jpg)
IntroductionMetal-enriched ground water may pose threats to aquatic
organisms in ground-water discharge areas in many environ-mental settings, particularly near hazardous-waste sites. The development of efficient and economical screening devices to detect metal-enriched ground water in streambed sediments near the ground-water/surface-water interface would enable investigators to assess potential threats to aquatic organisms and to identify areas of contaminated ground-water discharge. The data obtained from such reconnaissance-level sampling would then provide a basis for intensive site investigations. Because of this need for reconnaissance-level sampling devices, the U.S. Geological Survey (USGS), in coopera-tion of the U.S. Environmental Protection Agency (USEPA), through the Measurement and Monitoring for the 21st Century Initiative (21M2), conducted an investigation of the effective-ness during 2003 of the stainless-steel push-point sampler (PPS) and the nylon-screen diffusion sampler (NSDS). This Office of Solid Waste and Emergency Response (OSWER) ini-tiative is designed to identify and encourage the use of promis-ing measurement and monitoring technologies in response to waste-management and site-cleanup program needs by matching existing and emerging technologies with OSWER program and client needs. The investigation was carried out at two study areas with previously reported contamination: the Nyanza Chemical Waste Dump Superfund site (Campbell and others, 2002) along the Sudbury River in Ashland, MA, and at a Superfund site-assessment location along Rigby Brook in Clinton, MA. In particular, screening with these devices was intended to determine whether trace-metal concentra-tions exceeded guidelines (Project Action Limits, or PALs, also known as Surface Water Benchmarks, including Ambient Water Quality Criteria; Bart Hoskins, Ecological Risk Assessor, U.S. Environmental Protection Agency, written com-mun., 2002) intended to protect aquatic life, not to determine whether drinking-water criteria were exceeded or to detect these metals at trace-level concentrations.
The report includes results of laboratory-based quality-control studies. The chemical analyses for this investigation include results for 21 metals; however, the report focuses on the few metals that were most frequently detected.
The NSDS consists of a 63-mm diameter, 125-mL polypropylene jar (Thomas Scientific) with the center of the cap removed, and with only a screw-on rim for securing a piece of 120-µ nylon-screen mesh (Small Parts, Inc.). The mesh, approximately 10 cm by 10 cm, is placed over the jar’s mouth and secured by screwing the rim back onto the jar (fig. 1). The 125-mL volume of the NSDS is sufficient to meet the USEPA laboratory’s 100-mL sample-volume requirement. In practice, the NSDS is filled with deionized water, buried in the sediment and allowed to equilibrate with its environment. To minimize the possibility of contaminating the site with a metal shovel when inserting the NSDS into the sediment, a
shovel-like device constructed from 10-cm polyvinyl chloride (PVC) pipe (with 6.4-mm wall thickness) is used for sam-pler deployment (fig. 2). Beveled edges enable this shovel to penetrate even the coarsest sediments to a depth of at least 20 cm. Preliminary tests showed that concentrations of inor-ganic constituents in well water and arsenic (As) in streambed sediments in samples collected by NSDSs compared favorably with concentrations measured in samples collected by other methods (Vroblesky and others, 2002).
A PPS is designed to sample sediment pore water with minimal disturbance to the site. The PushPoint Extreme Sampler (fig. 3), the commercially produced model used in this study, consists of a 6.4-mm diameter, stainless-steel tube with a machined point and 4-cm-long slotted screen (0.635-mm slots) near the tip (Henry, 2001); this study used a 91-cm-long version of the sampler. An internal guard rod positioned within the bore adds rigidity to the sampler during insertion.
Filter
Hypodermic needle
MeshJar rim
Jar
Nylonelectrical tie
Figure 1. The 125-milliliter nylon-screen diffusion sampler.
2 Field Tests of Samplers for Detection of Metals in Sediment Pore Water, Ashland and Clinton, MA, 2003
![Page 8: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/8.jpg)
The PPS has been used to collect water for analysis of volatile organic compounds (VOCs) (Henry, 2001; Church and others, 2002; Zimmerman and others, 2005), but has not been tested for characterization of metals in pore water. Although USGS manuals recommend against using metal sampling devices to collect samples for metal analysis (Wilde and others 1999), that guidance is intended for sampling to determine low-level concentrations near detection levels, not the higher concentrations usually associated with contamination.
Not all sediments have physical characteristics that allow water to be drawn in readily through the PPS; fine organic material, silt, and clay may block the openings (Zimmerman and others, 2005). In these situations, the NSDS, which can be left buried in the sediments for any length of time, may prove more appropriate. Therefore, the efficacy of both tools was examined in this study.
Study AreasThe study areas (fig. 4) were selected because the com-
position and texture of their sediments differ from one another and may affect the efficacy of the two sampling devices. According to a previous study (Roy F. Weston, Inc., 2001), the Nyanza study area is within a zone affected by a ground-water plume that includes organic contaminants and metals such as As, beryllium (Be), chromium (Cr), cobalt (Co), manganese (Mn), and mercury (Hg). The local hydrogeologic setting includes glacial lake deposits, till, and fractured granite. The surficial streambed sediments at the Nyanza site contain decayed and living plant material.
Figure 2. PVC shovel for inserting nylon-screen diffusion sampler into sediments.
Figure 3. A, The 91-centimeter PushPoint Extreme Sampler; and B, Detail of tip. Screen is 4 centime-ters long and tube diameter is 6.4 millimeters.
A.
B.
4 cm
4 centimeters (cm)
Study Areas 3
![Page 9: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/9.jpg)
Figu
re 4
. Lo
catio
ns o
f stu
dy a
reas
: A, M
ill P
ond,
Sud
bury
Riv
er, A
shla
nd, M
assa
chus
etts
; and
B, R
igby
Bro
ok, C
linto
n, M
assa
chus
etts
.
4 Field Tests of Samplers for Detection of Metals in Sediment Pore Water, Ashland and Clinton, MA, 2003
![Page 10: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/10.jpg)
The Rigby Brook study area, which was the subject of a Superfund site-assessment investigation (Forest Lyford, U.S. Geological Survey, oral commun., 2002), is impounded by a beaver dam. An abandoned manufacturing plant and a former waste dump adjacent to the impounded area on Rigby Road were thought to be sources of contamination, prompting the
site assessment. The sediments of flooded areas of the Rigby Brook study area contained the remnants of plant matter, but many sampling sites there were primarily silty or sandy in nature. The coarse, sandy sediments of the Rigby Brook study area contrasted with the fine-grained sediments of the Nyanza study area.
42˚30'
0 50 KILOMETERS
0 50 MILES
73˚00' 72˚00'71˚00'
70˚00'
41˚30'
MASSACHUSETTSCLINTON
71˚42'30" 71˚42' 71˚41'30"
42˚25'
42˚25'30"
0
1000
300 600 FEET
200 METERS
STUDY AREA SHOWN IN SCHEMATIC IN FIGURE 8B
EXPLANATION
Base from Massachusetts Executive Office of Environmental Affairs, MassGIS, 1:24,000, 2004Polyconic projection, 1983 North American DatumMassachusetts coordinate system mainland zone
RIGBY BROOK STUDY AREA, CLINTON, MASSACHUSETTS4B.
Mossy Pond
62
Rigby
Bro
okFitch Road
Railroad Trackway
Railroad Trackway
Rai
lroa
d T
rack
way
WoodlawnCemetary
Brook Street Rigby Road
NORTHBOROUGH
BOYLSTON
LANCASTER
CLINTON
WESTBOYLSTON
PRINCETON STERLING
HOLDEN
BERLIN
MARLBOROUGH
SOUTHBOROUGH
BOLTON
HUDSON
BOX IN YELLOW SHOWN BELOW
Wachusett Reservoir
Wachusett Reservoir
Figure 4—Continued. Locations of study areas: A, Mill Pond, Sudbury River, Ashland, Massachusetts; and B, Rigby Brook, Clinton, Massachusetts.
Study Areas 5
![Page 11: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/11.jpg)
Study DesignThe study was divided into two distinct phases. First,
the equilibration time for the NSDS units was determined. Equilibration was tested at the USGS’s South Carolina Water Science Center in Columbia, SC, and at Columbia Analytical Services in Rochester, NY. Quality-control testing was done at the MA-RI Water Science Center in Northborough, MA, to determine whether the NSDSs, PPSs, or other equipment used introduced unacceptable contamination to samples. A com-mercial laboratory in South Carolina and Columbia Analytical Services analyzed the equilibration samples; the USEPA Region I Laboratory in Chelmsford, MA, used inductively coupled plasma-mass spectrometry (ICP-MS) to analyze the quality-control and field samples for dissolved metals.
The field investigation with the two types of sampling devices constituted the second phase of the study. The NSDS units were deployed for up to 2 weeks at 15 sites in each study area. One to five NSDSs were left at each site. Samples were collected at intermediate times at five sites in each study area. At the end of the 2-week period, the remaining NSDS and PPS samples were collected.
The field-study design, which included the insertion of multiple NSDS units at the same sites, was based on the implicit assumption of a homogeneous sedimentary envi-ronment. Coarse, and occasionally impenetrable, substrate, however, made it difficult to place samplers within 20 cm of each other. In practice, multiple samplers were deployed within about a 0.5-m radius. In addition, the PPSs were expected to capture the same pore water as the NSDSs dur-ing the same time intervals. Nonetheless, variability among the NSDS samples, in particular, and between the NSDS and PPS samples was expected. Replicate PPS samples collected without removing and reinserting the PPSs were expected to produce the most consistent results; replicate PPS samples collected from the same site after removing and reinserting the PPS 5 to 20 cm away from the original position were expected to demonstrate more variability than the other replicate PPS samples.
Preliminary Laboratory Testing and Analysis
Before deployment and sampling, the samplers were subjected to a series of laboratory quality-control tests. These tests determined the rate at which water inside the NSDS units equilibrated with the external environment and whether either the equipment or the sampling process could provide a source of sample contamination.
Sampler Equilibration
To determine the minimum time required for equilibra-tion with the external medium, various NSDS units were filled with deionized water and placed in a bucket of water contain-ing arsenic and chloride at concentrations of about 230 µg/L and 265 mg/L, respectively. On the first and fourth days of equilibration, one NSDS unit was removed from the bucket to provide a water sample for analysis. On the seventh day, two NSDS units were removed to provide duplicate water samples. On each of these days, water also was pumped from the test bucket for analysis. Arsenic and chloride concentra-tions in the NSDS units had equilibrated with concentrations in the test-bucket water by the first day (table 1). In a separate test, NSDSs were filled with deionized water and allowed to equilibrate in test containers holding solutions of 16 dissolved metals. Once a day, during a 4-day period, one NSDS was removed and samples from the NSDS and the test container were analyzed. After 4 days, concentrations of all but one metal in water from the samplers corresponded closely to con-centrations in the test solution (fig. 5). Only the results for Ag had a high relative percent difference (RPD); this difference probably was a result of decreased analytical accuracy because the Ag concentration was lower than that of the other analytes.
Table 1. Concentrations of solutes in water collected from bucket by using peristaltic pump and from 125-micron-mesh nylon-screen diffusion samplers immersed in the bucket, Novem-ber 2000.
[NS, not sampled; NSDS, nylon-screen diffusion samplers]
Day
Arsenic, in micrograms per liter
Chloride, in milligrams per liter
Sample pumped
from bucket
Sample from NSDS
Sample pumped
from bucket
Sample from NSDS
0 NS 0 NS 01 240 240 260 2704 240 250 270 2607 240 250 270 2607 230 240 270 270
6 Field Tests of Samplers for Detection of Metals in Sediment Pore Water, Ashland and Clinton, MA, 2003
![Page 12: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/12.jpg)
Equipment Blanks
NSDS parts, PPSs, and other pieces of sampling equip-ment were subjected to a series of equipment-blank tests in triplicate under controlled laboratory conditions. These tests were designed to determine if the equipment would release metals in concentrations high enough to interfere with the interpretation of analytical results from field-sampling applications.
Various NSDS units were separated into their constituent parts and soaked in 5 percent HCl in 19-L acid-cleaned plastic buckets for 3 days. The units were then rinsed with tap water and deionized water before soaking for 7 days in 4 L of deion-ized water obtained from the USEPA Region I Laboratory. Samples were collected from all of the containers and acidi-fied to pH 2 with Ultrex-grade nitric acid, as were all samples in this study. All samples were analyzed by the USEPA. The
data (table 2) indicate that, over the 7-day period, the plas-tic components did not release metals in concentrations that would compromise an investigation of a contaminated site. Three metals were detected: Barium (Ba), Copper (Cu), and Zinc (Zn). Ba was detected at the reporting level of 0.2 µg/L in a single sample; Cu was detected in two samples at con-centrations slightly higher than the reporting level of 1.0 µg/L (according to the official USEPA laboratory-data reports, the low-level Cu concentrations detected were caused by labora-tory or trip-blank contamination); and only one set of samples (the water from the bucket containing the plastic NSDS jar bottoms and nylon mesh) yielded consistent indications of a metal leaching from the sampler components; these samples had a mean (n=3, where n is the number of samples) Zn con-centration of 15 µg/L, approximately 12.5 percent of the PAL (table 3).
Ars
enic
Ber
ylliu
m
Cad
miu
m
Cal
cium
Chr
omiu
m
Cop
per
Iron
Lead
Nic
kel
Pot
assi
um
Sel
eniu
m
Silv
er
Sod
ium
Tha
llium
Zin
c
Ant
imon
y
Ars
enic
Ber
ylliu
m
Cad
miu
m
Cal
cium
Chr
omiu
m
Cop
per
Iron
Lead
Nic
kel
Pot
assi
um
Sel
eniu
m
Silv
er
Sod
ium
Tha
llium
Zin
c
Ant
imon
y
RE
LAT
IVE
PE
RC
EN
TD
IFF
ER
EN
CE
CO
NC
EN
TR
ATIO
N,
IN M
ILLI
GR
AM
S P
ER
LIT
ER
100
10
1
0.1
0.01
0
10
20
30
40
50
60
70
A.
B.
Test container
Nylon-screen diffusion sampler
Figure 5. Comparisons of A, concentrations; and B, relative percent differences between water samples obtained from the test container and from nylon-screen diffusion samplers after 4 days of equilibration.
Preliminary Laboratory Testing and Analysis 7
![Page 13: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/13.jpg)
Table 2. Concentrations of metals detected during quality-control testing of the sampling process.—Continued
[All laboratory (lab) blank water was obtained from the U.S. Environmental Protection Agency. Concentrations in micrograms per liter (parts per billion); NSDS, nylon-screen diffusion sampler; nd, not detected; PPS, pushpoint sampler; SS, stainless steel]
Quality-control sample Barium Calcium Copper Chromium Lead Manganese Nickel Zinc
Soaking NSDS Components
Lab blank water nd nd nd nd nd nd nd ndLab blank water nd nd nd nd nd nd nd ndLab blank water nd nd nd nd nd nd nd nd
Lab blank water collected from bucket 0.20 nd 1.2 nd nd nd nd 8.3Lab blank water collected from bucket nd nd 1.1 nd nd nd nd 7.2Lab blank water collected from bucket nd nd nd nd nd nd nd 7.1
Lab blank water from bucket with plastic jars and nylon mesh
nd nd nd nd nd nd nd 16
Lab blank water from bucket with plastic jars and nylon mesh
nd nd nd nd nd nd nd 14
Lab blank water from bucket with plastic jars and nylon mesh
nd nd nd nd nd nd nd 14
Lab blank water from bucket with plastic jar caps nd nd nd nd nd nd nd ndLab blank water from bucket with plastic jar caps nd nd nd nd nd nd nd ndLab blank water from bucket with plastic jar caps nd nd nd nd nd nd nd nd
NSDS Sampling Procedure
Lab blank poured from NSDS that was assembled then disassembled
nd 100 nd nd nd nd nd 29
Lab blank poured from NSDS that was assembled then disassembled
nd nd nd nd nd nd nd nd
Lab blank poured from NSDS that was assembled then disassembled
nd nd nd nd nd nd nd 5.8
Lab blank from NSDS using syringe only nd nd nd nd nd 0.21 nd 13Lab blank from NSDS using syringe only nd nd nd nd nd nd nd 11Lab blank from NSDS using syringe only nd nd nd nd nd nd nd 10
Lab blank from NSDS using syringe and SS hypodermic
0.23 nd 1.0 nd nd nd nd 16
Lab blank from NSDS using syringe and SS hypodermic
.26 nd 2.0 nd 1.2 nd 0.5 23
Lab blank from NSDS using syringe and SS hypodermic
nd nd 2.0 nd 1.1 nd nd 15
Lab blank from NSDS using syringe, SS hypodermic, and filter
23 nd 2.0 nd nd nd nd 5.5
Lab blank from NSDS using syringe, SS hypodermic, and filter
30 nd nd nd nd nd nd nd
Lab blank from NSDS using syringe, SS hypodermic, and filter
51 nd 1.0 nd nd nd nd 17
8 Field Tests of Samplers for Detection of Metals in Sediment Pore Water, Ashland and Clinton, MA, 2003
![Page 14: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/14.jpg)
Table 2. Concentrations of metals detected during quality-control testing of the sampling process.—Continued
[All laboratory (lab) blank water was obtained from the U.S. Environmental Protection Agency. Concentrations in micrograms per liter (parts per billion); NSDS, nylon-screen diffusion sampler; nd, not detected; PPS, pushpoint sampler; SS, stainless steel]
Quality-control sample Barium Calcium Copper Chromium Lead Manganese Nickel Zinc
PPS Sampling Procedure
PPS external rinse water nd nd 2.0 2.8 nd 1.9 2.7 41PPS external rinse water nd nd nd .73 nd 1.1 .76 16PPS external rinse water nd nd 1.0 1.9 nd 1.0 2.4 29
Peristaltic pump and tubing nd nd nd nd nd nd nd 7.8Peristaltic pump and tubing nd nd nd nd nd nd nd 7.3Peristaltic pump and tubing nd nd nd nd nd nd nd 8.1
Peristaltic pump, tubing, and PPS nd nd nd nd nd 10 .75 12Peristaltic pump, tubing, and PPS nd nd nd nd nd 9.5 .45 11Peristaltic pump, tubing, and PPS 6.3 nd nd nd nd 12 .54 11
Peristaltic pump, tubing, PPS, and filter nd nd nd nd nd 11 .7 ndPeristaltic pump, tubing, PPS, and filter 16 nd nd nd nd .61 nd ndPeristaltic pump, tubing, PPS, and filter 10 nd nd nd nd .34 nd nd
Table 3. Target analytes, their project action limits, and mini-mum reporting levels used for this study.
[na, not available]
AnalyteProject action limit
(micrograms per liter)
Reporting level (micrograms
per liter)
Aluminum (Al) 87 5Antimony (Sb) 30 .5Arsenic (As) 150 .5Barium (Ba) 4 .2Beryllium (Be) .66 .2
Cadmium (Cd) 2.2 .2Calcium (Ca) 116,000 100Chromium (Cr) 74 .5Cobalt (Co) 23 .2Copper (Cu) 9 .2
Iron (Fe) 1,000 50Lead (Pb) 2.5 .2Magnesium (Mg) 82,000 100Manganese (Mn) 120 .2Molybdenum (Mo) na .5
Nickel (Ni) 52 .2Selenium (Se) 5 1.0Silver (Ag) .36 .2Thallium (Tl) 12 .5Vanadium (V) 20 .2Zinc (Zn) 120 5
Preliminary Laboratory Testing and Analysis 9
![Page 15: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/15.jpg)
In addition, a second series of quality-control tests assessed the capacity for the sampling process to contaminate samples (table 2). Samples of deionized water were collected as components were sequentially added to the sampling appa-ratus. For example, an NSDS sample was first collected with only a syringe; next, a sample was collected with a syringe and a hypodermic needle; finally, a sample was collected after a 0.45-µ Millipore HPF Millex-HN filter unit was added to the syringe and hypodermic needle. Zn was detected in most of the samples; the highest average Zn concentration, 18 µg/L (n=3), or 15 percent of the PAL, was associated with the use of the stainless-steel hypodermic needle to collect the sample. Ba, at an average concentration (n=3) of 35 µg/L, was detected in association with the filter apparatus; this concentration exceeds the PAL (4 µg/L). On the other hand, use of the filter may have decreased the Zn concentrations in the samples. Detections of Cu were ascribed by the laboratory analytical data report to lab-blank or trip-blank contamination, not to the samples themselves. Other analytes were detected sporadically and at concentrations below their respective PALs.
A similar series of tests was performed on the PPS sam-pling components. Some Ba contamination was again detected in association with the filter. Cu, Cr, Mn, nickel (Ni), and Zn were detected in the external rinse water (fig. 6). The highest concentrations of Zn, the only commonly detected metal in these tests, was found in external rinse-water samples from the PPS at 41 µg/L, substantially less than the PAL of 120 µg/L. Cu was once more ascribed to lab or trip-blank contamina-tion. The concentrations of Cr, Mn, and Ni were also substan-tially less than their PALs of 74 µg/L, 120 µg/L, and 52 µg/L, respectively.
As stated previously, this process generally showed that maximum detected analyte concentrations were lower than the PALs. Ba exceeded its PAL in these quality-control tests only when the filter unit was included. Thus, if appropriate quality-control samples are collected, it is reasonable to assume that contamination from these devices is unlikely to affect data interpretations when investigating suspected sites of possible high contamination.
Bucke
t
Bucke
t, ca
ps
Bucke
t, jar
s, ny
lon m
esh
Blank w
ater
carb
oy
NSDS
NSDS (syr
inge)
NSDS (syr
inge,
hyp
oder
mic)
NSDS (syr
inge,
hyp
oder
mic,
filte
r)
PPS rins
ate
PPS, pum
p ho
se
PPS, pum
p ho
se, f
ilter
Pump
hose
0
10
20
30
40
50
60
BA
RIU
M C
ON
CE
NT
RA
TIO
N, I
N M
ICR
OG
RA
MS
PE
R L
ITE
R
Sample 1Sample 2Sample 3
A.
COMPONENT
Figure 6. Laboratory quality-control data for A, barium; and B, zinc for components of sampling equipment. (NSDS, nylon-screen diffusion sampler; PPS, pushpoint sampler)
10 Field Tests of Samplers for Detection of Metals in Sediment Pore Water, Ashland and Clinton, MA, 2003
![Page 16: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/16.jpg)
Sediment Pore Water Field-Sampling Techniques
Field work was done during May and June 2003. Field activities consisted of the deployment and retrieval of NSDSs and the collection of water samples from the NSDSs and the PPSs.
Nylon-Screen Diffusion Samplers
The NSDS units were assembled in the laboratory prior to transport to the study areas. Preliminary testing during a previous investigation indicated that deployment of sam-plers containing oxygenated water might affect the measured concentrations of contaminants (Forest P. Lyford, Hydrologist, U.S. Geological Survey, oral commun., 2003); there was con-cern that iron hydroxides could precipitate on the mesh screen and prevent dissolved metals from diffusing into the NSDS. To prevent this precipitation, the NSDS units were assembled in water that had been purged of dissolved oxygen (DO) by
sparging with nitrogen for at least 1 hour. Nitrogen was con-tinuously bubbled through the 19-L buckets in which the sam-plers were being prepared. These samplers were transported to the field sites in the buckets under a nitrogen atmosphere that was maintained by keeping the buckets covered except during the removal of a sampler. Because maintaining low DO con-centrations proved difficult, several NSDS units were prepared and deployed with deionized water that had not been purged of DO to determine whether deoxygenating made an appreciable difference in the results.
To deploy, or insert, the NSDSs into the sediment, the PVC shovel was pushed into the sediment and used to create a hole that would allow the sampler to be buried approximately 20 cm below the sediment surface. Each NSDS was covered with sediment after the shovel was removed. Samplers were placed on their sides to decrease the danger of puncturing the mesh during insertion and retrieval. To locate the samplers for retrieval, each NSDS unit was wrapped tightly with a nylon electrical tie attached to nylon monofilament and a brightly colored fishing bobber. During the study period, two bobbers were lost; because the monofilaments remained attached to
COMPONENT
Bucke
t
Bucke
t, ca
ps
Bucke
t, jar
s, ny
lon m
esh
Blank w
ater
carb
oy
NSDS
NSDS (syr
inge)
NSDS (syr
inge,
hyp
oder
mic)
NSDS (syr
inge,
hyp
oder
mic,
filte
r)
PPS rins
ate
PPS, pum
p ho
se
PPS, pum
p ho
se, f
ilter
Pump
hose
ZIN
C C
ON
CE
NT
RA
TIO
N, I
N M
ICR
OG
RA
MS
PE
R L
ITE
R
Sample 1Sample 2Sample 3
0
10
20
30
40
50B.
Figure 6—Continued. Laboratory quality-control data for A, barium; and B, zinc for components of sampling equipment. (NSDS, nylon-screen diffusion sampler; PPS, pushpoint sampler)
Sediment Pore Water Field-Sampling Techniques 11
![Page 17: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/17.jpg)
the samplers, however, they were all retrieved. Although some force was occasionally required to pull an NSDS loose from the sediment, it was usually possible to remove a sampler by gently gripping its sides. Any sediment covering the mesh usually fell off while the NSDS was being lifted through the overlying water. When it was necessary to use a gloved finger-tip to flick off a small amount of retained sediment, negligible loss of water from the sampler resulted.
NSDS samples were collected by using a 60-mL disposable syringe with a 13-gage, 8.9-cm hypodermic needle and a 25-mm, 0.45-µm filter unit (Millipore HPF Millex-HN) mounted between the syringe and hypodermic. After the NSDS was retrieved, the sharp tip of the hypodermic was thrust through the nylon mesh to extract the sample (fig. 7). Two withdrawals were required to retrieve a volume (100 mL) sufficient for analysis. Occasionally, more than one filter unit was required because of the build-up of solids on the filter membrane.
Pushpoint Samplers
During this study, a peristaltic pump was used to draw samples through the PPS. Approximately 2 m of silicone tubing connected the pump directly to the PPS. One of the Millipore filter units was attached to the opposite end of the tubing where the sample flowed into the 125-mL, high-density-polyethylene sample container before being acidified with Ultrex-grade nitric acid. After setting the PPS in the sediment at the desired depth, the guard rod was removed and samples were drawn with a peristaltic pump. During the flush-ing of the PPS and tubing prior to the collection of an envi-ronmental sample, specific conductance was monitored with a multiprobe meter to ensure that the PPS samples represented pore water and not infiltrating surface water.
Figure 7. Collecting a field sample from nylon-screen diffusion sampler by using syringe, filter, and hypodermic.
12 Field Tests of Samplers for Detection of Metals in Sediment Pore Water, Ashland and Clinton, MA, 2003
![Page 18: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/18.jpg)
Site Selections
On May 12, 2003, 15 sites were selected approximately 0.5 to 1.5 m from shore in the Sudbury River (fig. 8A) at the Nyanza study area in Ashland. Samplers were inserted about 20 cm below the sediment surface in water 15 to 30 cm deep and were retrieved on May 13, 15, 19, 27, and 28, 2003.
On May 20, on either side of Rigby Road, Clinton, 15 sites (fig. 8B) were selected in sediments at the bottom of ditches or a beaver-dammed impoundment. All sampling sites remained submerged during the sampling period. As at the Nyanza study area, samplers were inserted about 20 cm below the sediment surface. Samples were collected on May 21, 23, 28, June 4, and June 5, 2003.
Quality-Control Sampling and Results
Field quality-control sampling for the NSDS units consisted of retrieving duplicate samplers deployed in close proximity to each other at some of the 15 sites. Quality-control sampling for the PPSs included equipment blanks, sequential replicate samples from the same site without removal of the PPS, and replicate samples from a nearby spot at the same site. NSDS and PPS replicate sample results are discussed with the other field data.
After the PPS had been flushed out and its exterior rinsed with deionized water supplied by the USEPA laboratory, equipment blanks were collected. Approximately 1 L of deion-ized water was pumped from a Pyrex 1-L beaker through the PPS before a sample was collected. This volume was approxi-mately the same volume of water that was used to flush the sampling system before routine sample collection.
Analysis of the PPS field-equipment blanks (table 6, at back of report) indicated that neither sampling equipment nor procedure introduced contamination to the field samples sufficient to qualify the use of the samplers in detecting con-tamination near or above PALs. Only two metals, As and Ba, were detected in the samples: As detected once at 0.71 µg/L and Ba at an average concentration of 3.3 µg/L (n=5). (Cu was detected in the laboratory analysis, but these detections were ascribed to contamination of laboratory blanks.) Ba likely came from the filter unit, as observed during lab quality-control studies.
High concentrations of iron (Fe) and Mn in the envi-ronmental samples required the analysts to dilute samples to minimize interferences affecting the analyses. Diluting the samples increased reporting levels for all metals by the same factor. Field-blank samples were not all segregated from envi-ronmental samples during analysis, however, and, thus, some were diluted by the laboratory. The dilution increased their reporting levels and effectively censored some of the data. In particular, the field blanks from Nyanza were all diluted 10:1 and the Rigby Brook field blanks were undiluted.
Variability in the results by method at each study area was calculated by using the medians of Relative Percent Difference (RPD) (table 4); reporting levels were substi-tuted for nondetects. In this case, this substitution may have diminished the RPD values. A comparison of the nitrogen-sparged NSDS units and those that were not sparged (NSDSX in tables 4; 6–8, at back of report) yields ambiguous results. Reporting levels in the Nyanza samples higher than in the Rigby Brook samples make the Nyanza results appear less variable than those from Rigby Brook. In reality, the concen-trations of numerous nondetects among the metals at Nyanza were replaced by reporting-level concentrations for the RPD calculations. The large number of 0.0 median RPD values (As, Co, lead (Pb), Ni, and V) at the Nyanza site reflects this situation. Because the lower number of nondetects at the Rigby Brook site allowed calculations to be based on real measured concentrations, the median RPD values were higher. Overall, the median RPD calculations indicate a high variability between the NSDS and NSDSX units. The differ-ences between the units may be exaggerated because there are fewer NSDSX than NSDS samples. If the NSDS is to become a common field-sampling device, additional testing in more homogeneous media may be useful.
Sequential replicate samples collected at the same loca-tion with the PPSs (PP1 in tables 4, 6–8) generally exhibit low median RPD values. Only the results for Zn are higher than for other metals. The higher median RPD values for PP2 samples (replicate samples collected from sites within a 0.5-m radius of one another) at both study areas further demonstrate substan-tial environmental variability over short distances.
Sediment Pore Water Field-Sampling Techniques 13
![Page 19: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/19.jpg)
1415
1312
1110
98
76
54
32
1 05
1015
2025
30D
ISTA
NC
E A
LO
NG
SH
OR
EL
INE
, IN
ME
TE
RS
SUD
BU
RY
RIV
ER
A.
Sam
plin
g s
ite
nu
mb
ers
and
dis
tan
ces
alo
ng
th
e sh
ore
line
of
the
Nya
nza
stu
dy
area
, Ash
lan
d
B.
Sam
plin
g s
ite
nu
mb
ers
and
dis
tan
ces
alo
ng
Rig
by R
oad
, Clin
ton
Sch
emat
ic o
nly,
dis
tanc
es fr
om s
hore
not
to s
cale
Cop
ied
from
fiel
d no
tebo
ok; d
raw
ing
is n
ot to
sca
le
EX
PL
AN
AT
ION
SA
MP
LIN
G S
ITE
AN
D N
UM
BE
R
XXXXXX
XXXXXXR
IGB
Y R
OA
D, D
ISTA
NC
E IN
ME
TE
RS
0
XX
XX
Bea
ver
Dam
Bea
ver
Dam
s
Po
nd
ed A
rea
Po
nd
edA
rea
12
34
78
56
910
1112
1314
15
1.80
3.60
20.6
26.6
34.5
38.7
41.8
46.0
66.0
70.0
107
7.0
13.0
22.0
28.0
6
Cul
vert
Woo
ded
wet
land
Figu
re 8
. Di
strib
utio
n of
sam
plin
g si
tes
at th
e A,
Nya
nza
stud
y ar
ea, A
shla
nd, M
assa
chus
etts
; and
B, R
igby
Bro
ok s
tudy
are
a, C
linto
n, M
assa
chus
etts
.
14 Field Tests of Samplers for Detection of Metals in Sediment Pore Water, Ashland and Clinton, MA, 2003
![Page 20: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/20.jpg)
Comparison of Metal Concentrations in Pore Water Collected with Nylon-Screen Diffusion and Pushpoint Samplers
The distribution, frequency of detection, and concentra-tions of metals differed at sampling sites within each of the Nyanza and Rigby Brook study areas (tables 7 and 8). Some of these differences may reflect matrix interferences that, in all but the first eight samples from the Nyanza study area, made it necessary for the analyst to dilute the sample by a factor of 10; this dilution effectively raised the reporting level by the same factor, and probably caused a decrease in the frequency of low-level detections in these samples. Similarly, 46 of 78 sam-ples from the Rigby Brook site required 2:1 dilution because of interference caused by the high concentrations of Fe in the samples. Thus, differences in the extent of matrix interference between samples from the Nyanza and Rigby Brook study areas may account more for concentration differences in As, Cr, Pb, Mo, V, and Zn than differences between the physical characteristics of the study areas (tables 7 and 8; figs. 9 and 10). These decreases in analytical method sensitivities to low concentrations of metals, however, should not be considered as affecting the capacity of the two types of sampling devices to provide acceptable data from highly contaminated environ-ments.
Although the Nyanza and Rigby Brook sampling areas were expected to yield detections of a large number of metals in concentrations substantially exceeding their PALs and, therefore, classifying the concentrations as toxic, this result
did not prove to be the case. At Nyanza, only aluminum (Al), Ba, Fe, and Mn were detected frequently at concentrations higher than their PALs. These elements are not generally classified with the trace elements or contaminants of concern As, cadmium (Cd), Cr, Cu, Hg, Pb, and Ni. These results con-trast with findings from a Nyanza Chemical Dump Superfund Site monitoring study (ICF Consulting, 2003) conducted in June 2001 (table 5). Single water samples collected from 20-cm sediment depths in three monitoring wells in the vicinity of the present study site (fig. 4) and analyzed by ICP-MS yielded data with relatively high concentrations of metals; the con-centrations of Al, As, Cr, Pb, V, and Zn were particularly high in comparison with the concentrations detected during this study. The differences were generally consistent irrespective of whether the Superfund monitoring well was located within the plume zone (wells MP-03A-03 and MP-003-01) or outside the zone (well UR-002).
At Rigby Brook, concentrations of As, Ba, Fe, Mn, and Zn frequently exceeded their PALs. For these reasons, comparisons are limited primarily to these frequently detected trace metals (Al, As, Ba, Co, Fe, Mn, and Zn). The low concentrations and relatively infrequent detections reported for antimony (Sb), Cu, Cr, Pb, molybdenum (Mo), Ni, and V, however, show that even the metallic PPS can collect samples yielding barely detectable concentrations of these metals.
Boxplots noting the actual reporting levels and substitut-ing these reporting levels for nondetects (figs. 9 and 10) are useful in comparing the results for the two devices at the two study areas. This substitution may create an overestimation in the concentration distribution of frequently detected metals, but the inclusion of the reporting levels provides perspective and shows how the different reporting levels affect the data.
Table 4. Medians of paired relative percent-difference values for individual metals in nylon-screen diffusion samples and pushpoint samples collected at the Nyanza study area, Ashland, Massachusetts, and at the Rigby Brook study area, Clinton, Massachusetts.
[For these calculations, values for censored data were set at the reporting level (table 3). NSDS, nylon-screen diffusion sampler; NSDSX, nylon-screen diffusion sampler inserted without nitrogen sparging; PP1, pushpoint sampler—sequential replicate-sample pairs collected without moving sampler; PP2, pushpoint sampler—discrete sample pairs collected from nearby, but separate, locations]
Sampler type Aluminum Arsenic Barium Cobalt Iron Lead Manganese Nickel Vanadium Zinc
Nyanza
NSDS only 26.1 0.0 7.1 4.3 40.0 0.0 7.2 0.0 0.0 22.2NSDS and NSDSX 16.5 .0 6.5 .0 54.9 .0 18.2 .0 .0 48.5PP1 only 2.3 .0 6.4 .0 .0 .8 2.1 .0 1.4 25.4PP1 and PP2 12.8 .0 6.7 20.3 17.8 .0 6.1 23.9 .0 18.2
Rigby
NSDS only 44.3 25.4 12.1 29.2 33.1 40.0 7.9 21.3 24.2 5.1NSDS and NSDSX 58.3 32.5 8.1 26.1 39.8 68.8 46.6 55.8 29.1 4.4PP1 only 2.3 .0 6.4 .0 .0 .8 2.1 .0 1.4 25.4PP1 and PP2 16.2 16.2 10.4 40.5 18.2 27.3 12.2 23.0 22.2 40.0
Comparison of Metal Concentrations in Pore Water Collected with Nylon-Screen Diffusion and Pushpoint Samplers 15
![Page 21: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/21.jpg)
For most of the metals depicted in the boxplots for the Nyanza study area (fig. 9), the reporting level was 2.0 µ/L; the exceptions were Al, 50 µ/L; As, 5 µ/L; Fe, 500 µ/L; and Zn, 50 µ/L. Medians for As, Pb, and V for both devices did not exceed the reporting level; that is, most of the data were censored. At the Rigby Brook study area, the reporting level was generally 0.4 µ/L, with the result that most of the data that appear in the boxplots were uncensored (fig.10).
For the uncensored data, the boxplots show that the ranges of concentrations for the two devices are comparable (figs. 9 and 10). For the most part, the median concentrations for the two devices lie within each other’s interquartile ranges. Only Al and Ba at the Nyanza study area and Ba and Zn at the Rigby Brook study area do not conform to this pattern; in these cases, except for the Al comparison, the median concen-trations associated with the NSDS samples were higher than the median concentrations for the PPS samples. Therefore, for a general screening study in an area where conditions were unfavorable for the use of the PPS, the NSDS could serve as an adequate alternative method, if these concerns are adequately considered.
Time Series of Nylon-Screen Diffusion Sampler Data
In general, the metal concentrations from the NSDS units increased slightly after 1 day or remained approximately the same (figs. 11 and 12, at back of report). If the unit is used, 1 week would seem to suffice for the water inside NSDS units in sediments comparable to those studied here to reach concentrations comparable with concentrations in the outside water. Notable differences in metal concentrations among specific locations further indicate the environmental hetero-geneity of the two study areas. Fe, Mn, and Zn concentrations at Nyanza site 12 were highest early in the study period, and then gradually decreased (fig. 11). Some of the changes in concentrations reflected variations in reporting levels between sampling dates. This situation was most apparent for As and Zn in the Nyanza time series. With the need for dilution, the As reporting level changed from 0.5 µg/L on the first sampling date to 5.0 µg/L for the remainder of the samples; thus, As was detected at first, but not thereafter. Similarly, the reporting
LOG
CO
NC
EN
TR
AT
ION
, IN
MIC
RO
GR
AM
S P
ER
LIT
ER
x
oooooooooooooooooooooooooooooo ooooooooooooooooooooooooo
xxoo
o
xxo
xx
x
o
ooooooooooooooooooooooooooooo ooooooooooooooooooooooooo
xxxxxx
x
oooooooooooooooooooooooooooooo ooooooooooooooooooooooooo
ooo
ooo
o
x
Aluminu
m, P
PS
Aluminu
m, N
SDS
Arsen
ic, P
PS
Arsen
ic, N
SDS
Barium
, PPS
Barium
, NSDS
Cobalt
, PPS
Cobalt
, NSDS
Iron,
PPS
Iron,
NSDS
Lead
, PPS
Lead
, NSDS
Man
gane
se, P
PS
Man
gane
se, N
SDS
Nickel,
PPS
Nickel,
NSDS
Vanad
ium, P
PS
Vanad
ium, N
SDS
Zinc, P
PS
Zinc, N
SDS
30 25 30 25 30 25 30 25 30 25 30 25 30 25 30 25 30 25 30 25
30 NUMBER OF SAMPLES
EXPLANATION
x
x
o
o
HIGHEST DATA POINTWITHIN 1.5 TIMES THEINTERQUARTILE RANGEABOVE THE BOX
LOWEST DATA POINTWITHIN 1.5 TIMES THEINTERQUARTILE RANGEBELOW THE BOX
THIRD QUARTILE
MEDIAN
FIRST QUARTILE
OUTLIER GREATER THAN3.0 TIMES INTERQUARTILE RANGE ABOVE THE BOX
OUTLIER GREATER THAN3.0 TIMES INTERQUARTILE RANGE BELOW THE BOX
OUTLIER BETWEEN 1.5AND 3.0 TIMES THE INTERQUARTILE RANGEABOVE THE BOX
OUTLIER BETWEEN 1.5AND 3.0 TIMES THE INTERQUARTILE RANGEBELOW THE BOX
PPS -- Pushpoint Sampler
NSDS -- Nylon-Screen Diffusion Sampler
1
10
100
1,000
10,000
100,000
Detection Limit = 2
Detection Limit = 5
Detection Limit = 50
Detection Limit = 500
Figure 9. Selected metals concentrations in 25 samples collected with nylon-screen diffusion samplers and 35 samples collected with pushpoint samplers at the Nyanza study area, Ashland, Massachusetts, May 2003.
16 Field Tests of Samplers for Detection of Metals in Sediment Pore Water, Ashland and Clinton, MA, 2003
![Page 22: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/22.jpg)
level for Zn changed from 5.0 to 50 µg/L, which likely caused the nondetects or censored values at sites 3, 9, and 15 on and after May 19.
At the Rigby Brook study area, most of the concentration patterns for individual metals during the 2-week period were similar among the stations (fig. 12). In general, the final con-centrations of Co, Fe, Mn, and Zn were relatively high (com-pared to all sites) at sites 12 and 15 on the edge of the beaver-dam impoundment. Most of the initial and final concentrations did not differ substantially.
Comparison of all Nylon-Screen Diffusion Samples and Pushpoint Samples by Site
Comparing the results from samples collected from all sites at both study areas (figs. 13 and 14, at back of report) after the 2-week study period provides more insight into the relative usefulness of the two sample-collection devices. Because of the differences in detection frequencies and reporting levels (tables 6 and 7) between study areas, compar-
ing results for the same sets of metals is not practical. For example, the detections of Zn were infrequent at Nyanza, but frequent at Rigby Brook (figs. 11G and 12F).
The differences at the Nyanza sites for the NSDS and PPS results for Al were striking (fig. 13A). At sites 1 through 9 and 15, the PPS samples had higher Al concentrations than the NSDS samples. The mean Al concentration in the PPS samples was 519 µg/L, but 103 µg/L in the NSDS samples; the PPS sample concentrations were generally 300 µg/L or greater, whereas the NSDS sample concentrations were generally less than 200 µg/L. For sites 10 through 14, the concentrations of Al were approximately equal, but low. The similarity of values at these sites suggests that a local environmental difference, pH, for example, may have affected the chemical form in which Al occurred and retarded the diffusion of Al into the NSDS units at sites 1 through 9, but did not affect passage through the openings of the PPS. The similarities in Al con-centrations for both methods at Rigby Brook further support this hypothesis (fig. 14A).
x
xxxxx
x xx
xx
oo
o
-10
1
10
100
1,000
10,000
100,000
1,000,00034 24 34 24 34 24 34 24 34 24 34 24 34 24 34 24 34 24 34 24
30 NUMBER OF SAMPLES
EXPLANATION
x
x
o
o
HIGHEST DATA POINTWITHIN 1.5 TIMES THEINTERQUARTILE RANGEABOVE THE BOX
LOWEST DATA POINTWITHIN 1.5 TIMES THEINTERQUARTILE RANGEBELOW THE BOX
THIRD QUARTILE
MEDIAN
FIRST QUARTILE
OUTLIER GREATER THAN3.0 TIMES INTERQUARTILE RANGE ABOVE THE BOX
OUTLIER GREATER THAN3.0 TIMES INTERQUARTILE RANGE BELOW THE BOX
OUTLIER BETWEEN 1.5AND 3.0 TIMES THE INTERQUARTILE RANGEABOVE THE BOX
OUTLIER BETWEEN 1.5AND 3.0 TIMES THE INTERQUARTILE RANGEBELOW THE BOX
PPS -- Pushpoint Sampler
NSDS -- Nylon-Screen Diffusion SamplerAlum
inum
, PPS
Aluminu
m, N
SDS
Arsen
ic, P
PS
Arsen
ic, N
SDS
Barium
, PPS
Barium
, NSDS
Cobalt
, PPS
Cobalt
, NSDS
Iron,
PPS
Iron,
NSDS
Lead
, PPS
Lead
, NSDS
Man
gane
se, P
PS
Man
gane
se, N
SDS
Nickel,
PPS
Nickel,
NSDS
Vanad
ium, P
PS
Vanad
ium, N
SDS
Zinc, P
PS
Zinc, N
SDS
LOG
CO
NC
EN
TR
AT
ION
, IN
MIC
RO
GR
AM
S P
ER
LIT
ER
Detection Limit = 0.4
Detection Limit = 1
Detection Limit = 10
Detection Limit = 100
Figure 10. Selected metals concentrations in 24 samples collected with nylon-screen diffusion samplers and 34 samples collected with pushpoint samplers at the Rigby Brook study area, Clinton, Massachusetts, May to June 2003.
Comparison of Metal Concentrations in Pore Water Collected with Nylon-Screen Diffusion and Pushpoint Samplers 17
![Page 23: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/23.jpg)
With the exceptions of site 10 at Nyanza and site 11 at Rigby Brook, Ba concentrations in the NSDS samples at both study areas were generally two to three times higher than in the collocated PPS samples (figs. 13B and 14C). The Ba concentrations had a smaller range in the NSDS samples at Nyanza than those at Rigby Brook, but the ratio between the concentrations of Ba measured in the NSDS and PPS samples was approximately the same for the two study areas. Because there is no reason to expect the environmental concentra-tions of Ba in the NSDS samples to exceed those in the PPS samples, it seems reasonable to assume that Ba came either from the plastic containers or the filter units. The concentra-tions of As in samples taken by the PPS and NSDS at Rigby Brook (fig. 14B) did not indicate any systematic differences. Moreover, the concentrations of As in duplicate NSDS and PPS samples hardly differed.
Co concentrations in the Nyanza study-area samples (fig. 13C) were generally less than 40 µg/L, but differed sys-tematically between the PPS and NSDS. In a manner similar to that for Al, a local environmental condition may be respon-sible for the differences in Co concentrations between the PPS and NSDS. The PPS concentrations are generally higher than
the NSDS sample concentrations. The mean Co concentration in PPS samples was 37 µg/L, but 27 µg/L in the NSDS sam-ples. The differences were most obvious for sites 3 through 9, where all concentrations ranged from about 10 to 75 µg/L.
Fe and Mn concentrations from Nyanza showed similar distribution patterns at all sites (figs. 13D and 13E). At sites 1 through 9, the concentrations were lowest and varied little. At sites 10 through 14, the concentrations increased markedly as did their variations. At site 15, the concentrations converged again. There was no pattern of difference in concentrations between the two types of samplers for the Nyanza or Rigby Brook study areas (figs. 14D and 14E). At Rigby Brook sites 1 through 12 and 15, the concentrations of Fe and Mn were highest and most variable. At sites 13 and 14, Fe concentra-tions were lowest and varied only slightly; Mn concentrations were slightly lower at sites 13 and 14, but generally consistent between the samplers.
The concentrations of Zn in the NSDS samples from Rigby Brook were approximately an order of magnitude greater than those in the PPS samples (fig. 14F); generally, the concentration ranges were from 150 to 300 µg/L and from 10 to 25 µg/L for the NSDS and PPS samples, respectively. Only at site 11 were both PPS sample concentrations higher than those from the NSDS. Because Zn was commonly detected in the laboratory-blank samples from plastics, it is possible that leaching of Zn from the NSDS units was a source of the elevated concentrations.
Summary and ConclusionsTo assist investigators of environmental hazards in mak-
ing reconnaissance surveys of the sources and distribution of potentially hazardous metal concentrations, simple and economical devices are needed. The USGS, in cooperation with the USEPA, tested nylon-screen diffusion samplers and stainless-steel pushpoint samplers to determine and compare their efficacies in sampling shallow pore water for metal con-taminants. The investigation was carried out at two study sites with previously reported contamination: the Nyanza Chemical Waste Dump Superfund site along the Sudbury River in Ashland, MA, and a Superfund site-assessment location along Rigby Brook in Clinton, MA.
Clearly, nylon-screen diffusion samplers and pushpoint samplers can serve as field screening tools for most metals. Laboratory quality-control samples indicate that some low-concentration detections result from the use of either type of sampling device or from laboratory or field procedures. The results from the field studies indicate that metal concentrations in the PPS samples seem less affected by the sampler itself than those in the NSDS samples. With the exceptions of data that indicate leaching of Ba and Zn from the plastic NSDS, the
Table 5. Concentrations of metals detected in ground water 20 cm below sediment surface at selected well locations for the Nyanza Superfund Site, Ashland, Massachusetts, June 2001.
[Data from ICF Consulting, 2003. Concentrations in micrograms per liter; --, not detected]
MetalMonitoring wells
UR-002 MP-03A-03 MP-003-01
Aluminum 22,300 98,900 1,610Antimony 3.7 -- --Arsenic 20.8 43.6 4.5Barium 169 396 48.4
Beryllium 2.2 17.4 --Cadmium 2.4 6.4 .5Calcium 15,500 141,000 13,700Chromium 46.4 165 --
Cobalt 31.3 58.3 5.9Copper 45.4 103 --Iron 29,500 128,000 4,100Lead 192 191 28.2
Magnesium 6,380 50,800 3,660Manganese 1,210 30,500 673Nickel 20.7 59.1 --Silver -- 4.1 --
Vanadium 57.3 246 --Zinc 995 2,630 --
18 Field Tests of Samplers for Detection of Metals in Sediment Pore Water, Ashland and Clinton, MA, 2003
![Page 24: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/24.jpg)
differences in concentrations and frequencies of detection of the other metals among sites appear to be real, not artifacts of the devices used. The general comparability among the data from the PPS and NSDS samples show that the NSDS should prove effective at sites where the physical characteristics of the substrate might interfere with PPS use. The PPS is simpler and more convenient to use than the NSDS, however, because the NSDS requires assembly, preparation, insertion, and two site visits. In contrast, only one site visit is required to collect a sample with the PPS. Although NSDS units were left in place for 2 weeks during this study, the time-series data indicate that 1 week would have allowed adequate time to obtain a repre-sentative sample given the environmental heterogeneity that contributes to substantial variation in concentrations.
Most of the samples prepared for analysis were diluted by factors of 2 or 10 because of interferences affecting the analytical equipment. These dilutions raised the reporting levels for the metals by the same proportion and caused more analyses of the diluted samples than of undiluted samples to be reported as nondetects. The dilutions made it impossible to compare all sample concentrations with the lowest possible detection limits.
The data from samples from sparged and unsparged NSDS units analyzed for this report do not indicate that the use of the unsparged NSDS units would seriously affect the outcome of a screening survey of a contaminated site. Additional testing of NSDS units at sites with a greater variety of detectable metals could provide further support for this conclusion. Although demonstrating the use of the stainless-steel PPS for detecting low-level concentrations of trace-ele-ment metals was not an objective of this study, the results from undiluted samples indicate that the PPS may be useful in studies where low concentrations of trace metals are expected. With adequate quality-control sampling, scientifically sound results can be obtained for many applications.
AcknowledgmentsForest P. Lyford, Hydrologist, U.S. Geological Survey,
and Richard Willey, Hydrologist, U.S. Environmental Protection Agency, proposed this study and developed its ini-tial framework. The support and cooperation of Sharon Hayes, Remedial Program Manager, U.S. Environmental Protection Agency, is greatly appreciated. The authors would particularly like to recognize the field and office assistance provided by student aid Vicki-Rose Siegel. The authors gratefully acknowl-edge the residents and property owners who provided access to the study areas. Suggestions made by USGS colleague review-ers Matthew Petkewich and Kathryn M. Hess substantially improved this report.
References Cited
Campbell, J.P., Lyford, F.P., and Willey, R.E., 2002, Comparison of vapor concentrations of volatile organic compounds with ground-water concentrations of selected contaminants in sediments beneath the Sudbury River, Ashland, Massachusetts, 2000: U.S. Geological Survey Open-File Report 02-143, 33 p.
Church, P.E., Lyford, F.P., and Clifford, Scott, 2002, Volatile organic compounds, specific conductance, and tem-perature in the bottom sediments of Mill Pond, Ashland, Massachusetts, April 2001: U.S. Geological Survey Open-File Report 02-35, 10 p.
Henry, M.H., 2001, PushPoint Sampler Operators Manual and Applications Guide, last accessed on June 15, 2004, at http://www-personal.engin.umich.edu/~markhen/ MHE-instructions-ver-2.00.doc
ICF Consulting, 2003, Semi-annual ground water monitor-ing report—Spring 2003: Ashland, MA, Nyanza Chemical Waste Dump Superfund Site Operable Unit II, variously paged.
Roy F. Weston, Inc., 1999, Evaluation of contamination, Nyanza Chemical Waste Dump Superfund Site, Ashland, Massachusetts: Manchester, NH, variously paged.
Roy F. Weston, Inc., 2001, Draft groundwater toxicity evalua-tion report, Nyanza Chemical Waste Dump Superfund Site, Ashland, Massachusetts: Manchester, NH, variously paged.
Vroblesky, D.A., Petkewich, M.D., and Campbell, T.R., 2002, Field tests of diffusion samplers for inorganic constitu-ents in wells and at a ground-water-discharge zone: U.S. Geological Survey Water-Resources Investigations Report 02-4031, 24 p.
Wilde, F.D., Radtke, D.B., Gibs, J., Iwatsubo, R.T., 1999, Processing of water samples, in Wilde, F.D., Radtke, D.B., Gibs, J., and Iwatsubo, R.T., eds., National Field Manual for the Collection of Water-Quality Data: U.S. Geological Survey Techniques of Water-Resources Investigations, Book 9, chap A5, variously paged.
Zimmerman, M.J., Massey, A.J., and Campo, K.W., 2005, Pushpoint sampling for defining spatial and temporal variations of contaminant concentrations in sediment pore water near the ground-water/surface-water interface: U.S. Geological Survey Scientific Investigations Report 2005-5036, 70 p.
References Cited 19
![Page 25: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/25.jpg)
Figures 11–14 and Tables 6–8
20 Field Tests of Samplers for Detection of Metals in Sediment Pore Water, Ashland and Clinton, MA, 2003
![Page 26: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/26.jpg)
0
50
100
150 A
LUM
INU
M C
ON
CE
NT
RA
TIO
N,
IN M
ICR
OG
RA
MS
PE
R L
ITE
R
Site 3Site 6Site 9Site 12Site 15
Mean of Two Values
Reporting Level = 50Reporting Level = 5.0
A.
5/13
/200
3
5/15
/200
3
5/17
/200
3
5/19
/200
3
5/21
/200
3
5/23
/200
3
5/25
/200
3
5/27
/200
3
5/29
/200
3
DATE
0
0.5
1.0
1.5
2.0
2.5
AR
SE
NIC
CO
NC
EN
TR
AT
ION
,IN
MIC
RO
GR
AM
S P
ER
LIT
ER
Site 3Site 6Site 9Site 12Site 15
Mean of Two Values
Reporting Level = 2.0Reporting Level = 0.20
Not detected in any samples after 5/13/2003
B.
Figure 11. Time series data for A, aluminum; B, arsenic; C, barium; D, cobalt; E, iron; F, manganese; and G, zinc at the Nyanza study area, Ashland, Massachusetts, May 2003. Site locations are shown in figure 8.
Figures 11–14 21
![Page 27: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/27.jpg)
0
50
100
150
200
250
300
350
BA
RIU
M C
ON
CE
NT
RA
TIO
N,
IN M
ICR
OG
RA
MS
PE
R L
ITE
R
Site 3Site 6Site 9Site 12Site 15
Mean of Two Values
Reporting Level = 2.0Reporting Level = 0.2
5/13
/200
3
5/15
/200
3
5/17
/200
3
5/19
/200
3
5/21
/200
3
5/23
/200
3
5/25
/200
3
5/27
/200
3
5/29
/200
30
5
10
15
20
25
30
CO
BA
LT C
ON
CE
NT
RA
TIO
N,
IN M
ICR
OG
RA
MS
PE
R L
ITE
R
Site 3Site 6Site 9Site 12Site 15
Mean of Two Values
Reporting Level = 2.0Reporting Level = 0.2
DATE
D.
C.
Figure 11—Continued. Time series data for A, aluminum; B, arsenic; C, barium; D, cobalt; E, iron; F, manganese; and G, zinc at the Nyanza study area, Ashland, Massachusetts, May 2003. Site locations are shown in figure 8.
22 Field Tests of Samplers for Detection of Metals in Sediment Pore Water, Ashland and Clinton, MA, 2003
![Page 28: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/28.jpg)
IRO
N C
ON
CE
NT
RA
TIO
N,
IN M
ICR
OG
RA
MS
PE
R L
ITE
R
Site 3Site 6Site 9Site 12Site 15
Mean of Two Values
Reporting Level = 500Reporting Level = 50
0
5,000
10,000
15,000
20,000
25,000
30,000
35,000
40,000
E.
5/13
/200
3
5/15
/200
3
5/17
/200
3
5/19
/200
3
5/21
/200
3
5/23
/200
3
5/25
/200
3
5/27
/200
3
5/29
/200
3
MA
NG
AN
ES
E C
ON
CE
NT
RA
TIO
N,
IN M
ICR
OG
RA
MS
PE
R L
ITE
R
Site 3Site 6Site 9Site 12Site 15
Mean of Two ValuesReporting Level = 2.0Reporting Level = 0.2
DATE
0
100
200
300
400
500
600
700
800
900
1,000
1,100
1,200
F.
Figure 11—Continued. Time series data for A, aluminum; B, arsenic; C, barium; D, cobalt; E, iron; F, manganese; and G, zinc at the Nyanza study area, Ashland, Massachusetts, May 2003. Site locations are shown in figure 8.
Figures 11–14 23
![Page 29: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/29.jpg)
5/13
/200
3
5/15
/200
3
5/17
/200
3
5/19
/200
3
5/21
/200
3
5/23
/200
3
5/25
/200
3
5/27
/200
3
5/29
/200
30
50
100
150
200
ZIN
C C
ON
CE
NT
RA
TIO
N,
IN M
ICR
OG
RA
MS
PE
R L
ITE
R
Site 3Site 6Site 9Site 12Site 15
Mean of Two ValuesReporting Level = 50Reporting Level = 5.0
DATE
G.
Figure 11—Continued. Time series data for A, aluminum; B, arsenic; C, barium; D, cobalt; E, iron; F, manganese; and G, zinc at the Nyanza study area, Ashland, Massachusetts, May 2003. Site locations are shown in figure 8.
24 Field Tests of Samplers for Detection of Metals in Sediment Pore Water, Ashland and Clinton, MA, 2003
![Page 30: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/30.jpg)
0
30
15
45
60
90
120
135
105
180
ALU
MIN
UM
CO
NC
EN
TR
AT
ION
, IN
MIC
RO
GR
AM
S P
ER
LIT
ER
Site 3Site 6Site 9Site 12Site 15
Mean of Two ValuesReporting Level = 10Reporting Level = 5
75
150
165
5/21
/200
3
5/23
/200
3
5/25
/200
3
5/27
/200
3
5/29
/200
3
5/31
/200
3
6/2/
2003
6/4/
2003
6/6/
2003
0
100
200
300
400
500
600
AR
SE
NIC
CO
NC
EN
TR
AT
ION
, IN
MIC
RO
GR
AM
S P
ER
LIT
ER
Site 3Site 6Site 9Site 12Site 15
Mean of Two ValuesReporting Level = 1.0Reporting Level = 0.5
DATE
B.
A.
Figure 12. Time series data for A, aluminum; B, arsenic; C, barium; D, cobalt; E, iron; F, manganese; and G, zinc at the Rigby Brook study area, Clinton, Massachusetts, May to June 2003. Site locations are shown in figure 8.
Figures 11–14 25
![Page 31: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/31.jpg)
0
100
200
300
400
500
BA
RIU
M C
ON
CE
NT
RA
TIO
N,
IN M
ICR
OG
RA
MS
PE
R L
ITE
R
Site 3Site 6Site 9Site 12Site 15
Mean of Two Values
Reporting Level = 0.4Reporting Level = 0.2
C.
5/22
/200
3
5/24
/200
3
5/26
/200
3
5/28
/200
3
5/30
/200
3
6/1/
2003
6/3/
2003
6/6/
2003
0
5
10
15
20
CO
BA
LT C
ON
CE
NT
RA
TIO
N,
IN M
ICR
OG
RA
MS
PE
R L
ITE
R
Site 3Site 6Site 9Site 12Site 15
Mean of Two ValuesReporting Level = 0.4Reporting Level = 0.2
D.
DATE
Figure 12—Continued. Time series data for A, aluminum; B, arsenic; C, barium; D, cobalt; E, iron; F, manganese; and G, zinc at the Rigby Brook study area, Clinton, Massachusetts, May to June 2003. Site locations are shown in figure 8.
26 Field Tests of Samplers for Detection of Metals in Sediment Pore Water, Ashland and Clinton, MA, 2003
![Page 32: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/32.jpg)
IRO
N C
ON
CE
NT
RA
TIO
N,
IN M
ICR
OG
RA
MS
PE
R L
ITE
R
Site 3Site 6Site 9Site 12Site 15
Mean of Two ValuesReporting Level = 100Reporting Level = 50
0
40,000
80,000
120,000
160,000
E.
5/22
/200
3
5/24
/200
3
5/26
/200
3
5/28
/200
3
5/30
/200
3
6/1/
2003
6/3/
2003
6/6/
2003
0
500
1,000
1,500
2,000
2,500
3,000
MA
NG
AN
ES
E C
ON
CE
NT
RA
TIO
N,
IN M
ICR
OG
RA
MS
PE
R L
ITE
R
Site 3Site 6Site 9Site 12Site 15
Mean of Two ValuesReporting Level = 0.4Reporting Level = 0.2
DATE
F.
Figure 12—Continued. Time series data for A, aluminum; B, arsenic; C, barium; D, cobalt; E, iron; F, manganese; and G, zinc at the Rigby Brook study area, Clinton, Massachusetts, May to June 2003. Site locations are shown in figure 8.
Figures 11–14 27
![Page 33: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/33.jpg)
5/22
/200
3
5/24
/200
3
5/26
/200
3
5/28
/200
3
5/30
/200
3
6/1/
2003
6/3/
2003
6/6/
2003
0
50
100
150
200
250
300
ZIN
C C
ON
CE
NT
RA
TIO
N,
IN M
ICR
OG
RA
MS
PE
R L
ITE
R
Site 3Site 6Site 9Site 12Site 15
Mean of Two ValuesReporting Level = 10Reporting Level = 5
DATE
G.
Figure 12—Continued. Time series data for A, aluminum; B, arsenic; C, barium; D, cobalt; E, iron; F, manganese; and G, zinc at the Rigby Brook study area, Clinton, Massachusetts, May to June 2003. Site locations are shown in figure 8.
28 Field Tests of Samplers for Detection of Metals in Sediment Pore Water, Ashland and Clinton, MA, 2003
![Page 34: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/34.jpg)
SITE
0
200
400
600
800
1,000
1,200
1,400
ALU
MIN
UM
CO
NC
EN
TR
AT
ION
, IN
MIC
RO
GR
AM
S P
ER
LIT
ER
NSDSNSDSXPP1PP2
10 155 20 25 300
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
DISTANCE FROM REFERENCE STARTING POINT, IN METERSA.
Figure 13. Results for final round of sampling with nylon-screen diffusion samplers and pushpoint samplers for A, aluminum; B, barium; C, cobalt; D, iron; E, manganese; and F, zinc at all Nyanza study-area sampling sites, Ashland, Massachusetts, May 2003. NSDS, nylon-screen diffusion sampler; NSDSX, nylon-screen diffusion sampler initially filled with aerated deionized water; PP1, sample from first pushpoint-sampling location; PP2, sample from second pushpoint-sampling location. Site locations are shown in figure 8.
Figures 11–14 29
![Page 35: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/35.jpg)
SITE
0
100
200
300
400
BA
RIU
M C
ON
CE
NT
RA
TIO
N, I
N M
ICR
OG
RA
MS
PE
R L
ITE
R
NSDSNSDSXPP1PP2
1050 15 20 25 30
DISTANCE FROM REFERENCE STARTING POINT, IN METERS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
B.
Figure 13—Continued. Results for final round of sampling with nylon-screen diffusion samplers and pushpoint sam-plers for A, aluminum; B, barium; C, cobalt; D, iron; E, manganese; and F, zinc at all Nyanza study-area sampling sites, Ashland, Massachusetts, May 2003. NSDS, nylon-screen diffusion sampler; NSDSX, nylon-screen diffusion sampler initially filled with aerated deionized water; PP1, sample from first pushpoint-sampling location; PP2, sample from second pushpoint-sampling location. Site locations are shown in figure 8.
30 Field Tests of Samplers for Detection of Metals in Sediment Pore Water, Ashland and Clinton, MA, 2003
![Page 36: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/36.jpg)
Figure 13—Continued. Results for final round of sampling with nylon-screen diffusion samplers and pushpoint sam-plers for A, aluminum; B, barium; C, cobalt; D, iron; E, manganese; and F, zinc at all Nyanza study-area sampling sites, Ashland, Massachusetts, May 2003. NSDS, nylon-screen diffusion sampler; NSDSX, nylon-screen diffusion sampler ini-tially filled with aerated deionized water; PP1, sample from first pushpoint-sampling location; PP2, sample from second pushpoint-sampling location. Site locations are shown in figure 8.
SITE
0
20
40
60
80
CO
BA
LT C
ON
CE
NT
RA
TIO
N, I
N M
ICR
OG
RA
MS
PE
R L
ITE
R
NSDSNSDSXPP1PP2
DISTANCE FROM REFERENCE STARTING POINT, IN METERS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
1050 15 20 25 30
C.
Figures 11–14 31
![Page 37: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/37.jpg)
Figure 13—Continued. Results for final round of sampling with nylon-screen diffusion samplers and pushpoint samplers for A, aluminum; B, barium; C, cobalt; D, iron; E, manganese; and F, zinc at all Nyanza study-area sampling sites, Ashland, Massachusetts, May 2003. NSDS, nylon-screen diffusion sampler; NSDSX, nylon-screen diffusion sampler initially filled with aerated deionized water; PP1, sample from first pushpoint-sampling location; PP2, sample from second pushpoint-sampling location. Site locations are shown in figure 8.
0
20,000
40,000
60,000
80,000
IRO
N C
ON
CE
NT
RA
TIO
N, I
N M
ICR
OG
RA
MS
PE
R L
ITE
R
NSDSNSDSXPP1PP2
DISTANCE FROM REFERENCE STARTING POINT, IN METERS
SITE
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
1050 15 20 25 30
D.
32 Field Tests of Samplers for Detection of Metals in Sediment Pore Water, Ashland and Clinton, MA, 2003
![Page 38: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/38.jpg)
Figure 13—Continued. Results for final round of sampling with nylon-screen diffusion samplers and pushpoint samplers for A, aluminum; B, barium; C, cobalt; D, iron; E, manganese; and F, zinc at all Nyanza study-area sampling sites, Ashland, Massachusetts, May 2003. NSDS, nylon-screen diffusion sampler; NSDSX, nylon-screen diffusion sampler initially filled with aerated deionized water; PP1, sample from first pushpoint-sampling location; PP2, sample from second pushpoint-sampling location. Site locations are shown in figure 8.
0
500
1,000
1,500
2,000
MA
NG
AN
ES
E C
ON
CE
NT
RA
TIO
N,
IN M
ICR
OG
RA
MS
PE
R L
ITE
R
NSDSNSDSXPP1PP2
DISTANCE FROM REFERENCE STARTING POINT, IN METERS
SITE
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
1050 15 20 25 30
E.
Figures 11–14 33
![Page 39: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/39.jpg)
Figure 13—Continued. Results for final round of sampling with nylon-screen diffusion samplers and pushpoint samplers for A, aluminum; B, barium; C, cobalt; D, iron; E, manganese; and F, zinc at all Nyanza study-area sampling sites, Ashland, Massachusetts, May 2003. NSDS, nylon-screen diffusion sampler; NSDSX, nylon-screen diffusion sampler initially filled with aerated deionized water; PP1, sample from first pushpoint-sampling location; PP2, sample from second pushpoint-sampling location. Site locations are shown in figure 8.
SITE
0
200
400
600
800
ZIN
C C
ON
CE
NT
RA
TIO
N, I
N M
ICR
OG
RA
MS
PE
R L
ITE
R
NSDSNSDSXPP1PP2
0 10 20 30 40 50 60 70 80 90 100 110
DISTANCE FROM REFERENCE STARTING POINT, IN METERSF.
111 2 3333 44 56 777 8 9 10 11 12 13 14 15
34 Field Tests of Samplers for Detection of Metals in Sediment Pore Water, Ashland and Clinton, MA, 2003
![Page 40: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/40.jpg)
SITE
0
50
100
150
200
ALU
MIN
UM
CO
NC
EN
TR
AT
ION
, IN
MIC
RO
GR
AM
S P
ER
LIT
ER
NSDSNSDSXPP1PP2
0 10 20 30 40 50 60 70 80 90 100 110
DISTANCE FROM REFERENCE STARTING POINT, IN METERSA.
111 2 3333 44 56 777 8 9 10 11 12 13 14 15
Figure 14. Results for final round of sampling with nylon-screen diffusion samplers and pushpoint samplers for A, aluminum; B, arsenic; C, barium; D, iron; E, manganese; and F, zinc at all Rigby Brook study-area sampling sites, Clinton, Massachusetts, June 2003. NSDS, nylon-screen diffusion sampler; NSDSX, nylon-screen diffusion sampler initially filled with aerated deionized water; PP1, sample from first pushpoint-sampling location; PP2, sample from second pushpoint-sampling location. Site locations are shown in figure 8.
Figures 11–14 35
![Page 41: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/41.jpg)
SITE
AR
SE
NIC
CO
NC
EN
TR
AT
ION
, IN
MIC
RO
GR
AM
S P
ER
LIT
ER
NSDSNSDSXPP1PP2
0 10 20 30 40 50 60 70 80 90 100 110
DISTANCE FROM REFERENCE STARTING POINT, IN METERSB.
111 2 3333 44 56 777 8 9 10 11 12 13 14 150
200
400
600
800
1,000
1,200
Figure 14—Continued. Results for final round of sampling with nylon-screen diffusion samplers and pushpoint samplers for A, aluminum; B, arsenic; C, barium; D, iron; E, manganese; and F, zinc at all Rigby Brook study-area sampling sites, Clinton, Massachusetts, June 2003. NSDS, nylon-screen diffusion sampler; NSDSX, nylon-screen diffusion sampler ini-tially filled with aerated deionized water; PP1, sample from first pushpoint-sampling location; PP2, sample from second pushpoint-sampling location. Site locations are shown in figure 8.
36 Field Tests of Samplers for Detection of Metals in Sediment Pore Water, Ashland and Clinton, MA, 2003
![Page 42: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/42.jpg)
Figure 14—Continued. Results for final round of sampling with nylon-screen diffusion samplers and pushpoint sam-plers for A, aluminum; B, arsenic; C, barium; D, iron; E, manganese; and F, zinc at all Rigby Brook study-area sampling sites, Clinton, Massachusetts, June 2003. NSDS, nylon-screen diffusion sampler; NSDSX, nylon-screen diffusion sampler initially filled with aerated deionized water; PP1, sample from first pushpoint-sampling location; PP2, sample from second pushpoint-sampling location. Site locations are shown in figure 8.
SITE
0
100
200
300
400
500
BA
RIU
M C
ON
CE
NT
RA
TIO
N, I
N M
ICR
OG
RA
MS
PE
R L
ITE
R
NSDSNSDSXPP1PP2
0 10 20 30 40 50 60 70 80 90 100 110
DISTANCE FROM REFERENCE STARTING POINT, IN METERSC.
111 2 3333 44 56 777 8 9 10 11 12 13 14 15
Figures 11–14 37
![Page 43: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/43.jpg)
Figure 14—Continued. Results for final round of sampling with nylon-screen diffusion samplers and pushpoint samplers for A, aluminum; B, arsenic; C, barium; D, iron; E, manganese; and F, zinc at all Rigby Brook study-area sampling sites, Clinton, Massachusetts, June 2003. NSDS, nylon-screen diffusion sampler; NSDSX, nylon-screen diffusion sampler ini-tially filled with aerated deionized water; PP1, sample from first pushpoint-sampling location; PP2, sample from second pushpoint-sampling location. Site locations are shown in figure 8.
SITE
0
50,000
100,000
150,000
200,000
250,000
IRO
N C
ON
CE
NT
RA
TIO
N, I
N M
ICR
OG
RA
MS
PE
R L
ITE
R
NSDSNSDSXPP1PP2
0 10 20 30 40 50 60 70 80 90 100 110
DISTANCE FROM REFERENCE STARTING POINT, IN METERSD.
111 2 3333 44 56 777 8 9 10 11 12 13 14 15
38 Field Tests of Samplers for Detection of Metals in Sediment Pore Water, Ashland and Clinton, MA, 2003
![Page 44: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/44.jpg)
Figure 14—Continued. Results for final round of sampling with nylon-screen diffusion samplers and pushpoint samplers for A, aluminum; B, arsenic; C, barium; D, iron; E, manganese; and F, zinc at all Rigby Brook study-area sampling sites, Clinton, Massachusetts, June 2003. NSDS, nylon-screen diffusion sampler; NSDSX, nylon-screen diffusion sampler initially filled with aerated deionized water; PP1, sample from first pushpoint-sampling location; PP2, sample from second pushpoint-sampling location. Site locations are shown in figure 8.
SITE
0
1,000
2,000
3,000
4,000
MA
NG
AN
ES
E C
ON
CE
NT
RA
TIO
N,
IN M
ICR
OG
RA
MS
PE
R L
ITE
R
NSDSNSDSXPP1PP2
0 10 20 30 40 50 60 70 80 90 100 110
DISTANCE FROM REFERENCE STARTING POINT, IN METERSE.
111 2 3333 44 56 777 8 9 10 11 12 13 14 15
Figures 11–14 39
![Page 45: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/45.jpg)
1111 222 333333 444444 55566666666 7777788888 999999 10101010 111111 1212121212121212 1313131313 14141414 1515151515151515
SITE
0
200
400
600
800NSDSNSDSXPP1PP2
0 10 20 30 40 50 60 70 80 90 100 110
DISTANCE FROM REFERENCE STARTING POINT, IN METERSF.
ZIN
C C
ON
CE
NT
RA
TIO
N, I
N M
ICR
OG
RA
MS
PE
R L
ITE
R
Figure 14—Continued. Results for final round of sampling with nylon-screen diffusion samplers and pushpoint sam-plers for A, aluminum; B, arsenic; C, barium; D, iron; E, manganese; and F, zinc at all Rigby Brook study-area sampling sites, Clinton, Massachusetts, June 2003. NSDS, nylon-screen diffusion sampler; NSDSX, nylon-screen diffusion sampler initially filled with aerated deionized water; PP1, sample from first pushpoint-sampling location; PP2, sample from second pushpoint-sampling location. Site locations are shown in figure 8.
40 Field Tests of Samplers for Detection of Metals in Sediment Pore Water, Ashland and Clinton, MA, 2003
![Page 46: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/46.jpg)
Tabl
e 6.
Co
ncen
tratio
ns o
f met
als
in q
ualit
y-co
ntro
l sam
ples
dur
ing
field
stu
dies
at t
he N
yanz
a st
udy
area
, Ash
land
, Mas
sach
uset
ts, a
nd th
e Ri
gby
Broo
k st
udy
area
, Clin
ton,
M
assa
chus
etts
.—Co
ntin
ued
[See
tabl
e 3
for
defi
nitio
ns o
f at
omic
sym
bols
(an
alyt
es).
Rep
ortin
g le
vel f
or b
old
data
was
10
times
the
nom
inal
rep
ortin
g le
vel (
tabl
e 3)
; rep
ortin
g le
vel f
or s
hade
d da
ta w
as tw
ice
the
nom
inal
rep
ortin
g le
vel.
All
conc
entr
atio
ns a
re in
mic
rogr
ams
per
liter
, exc
ept f
or c
alci
um a
nd m
agne
sium
, whi
ch a
re in
mill
igra
ms
per
liter
. Sam
ple
iden
tifie
rs a
nd s
ite n
umbe
rs p
rece
ded
by th
e le
tter
R a
re a
ssoc
iate
d w
ith th
e R
igby
B
rook
stu
dy a
rea;
oth
ers
are
from
the
Nya
nza
stud
y ar
ea. N
SDS,
nyl
on-s
cree
n di
ffus
ion
sam
pler
; NSD
SX, n
ylon
-scr
een
diff
usio
n sa
mpl
er in
itial
ly f
illed
with
aer
ated
dei
oniz
ed w
ater
; PP1
, sam
ple
from
fir
st
push
poin
t-sa
mpl
ing
loca
tion;
PP2
, sam
ple
from
sec
ond
push
poin
t-sa
mpl
ing
loca
tion;
nd,
not
det
ecte
d]
Sam
ple
iden
t-
ifier
Site
nu
mbe
r (fi
g. 8
)D
ate
Tim
e Sa
mpl
er
type
Al
SbA
sB
aB
eCd
CaCr
CoCu
FePb
Mg
Mn
Mo
Ni
VZn
NSD
S D
uplic
ates
181
5-27
-200
310
25N
SDS
100
ndnd
260
ndnd
29nd
nd4.
85,
000
nd2.
475
0nd
ndnd
6519
15-
27-2
003
1035
NSD
S13
0nd
nd26
0nd
nd31
nd5.
03.
059
0nd
3.0
710
ndnd
nd67
284
5-27
-200
312
10N
SDS
90nd
nd29
0nd
nd34
nd17
.04.
01,
500
nd2.
572
0nd
5.2
ndnd
294
5-27
-200
312
20N
SDS
nd28
nd27
0nd
nd32
ndnd
7.0
8,70
0nd
2.4
670
nd5.
0nd
nd
325
5-27
-200
301
10N
SDS
93nd
nd29
0nd
nd31
nd23
.029
.01,
800
nd2.
366
0nd
8.4
ndnd
335
5-27
-200
301
25N
SDS
110
ndnd
270
ndnd
31nd
25.0
6.0
1,30
0nd
2.3
690
nd8.
5nd
nd34
55-
27-2
003
0135
NSD
SX21
0nd
nd30
0nd
nd31
nd17
.08.
074
0nd
2.3
690
nd8.
3nd
82
376
5-27
-200
314
20N
SDS
110
ndnd
280
ndnd
32nd
43.0
4.0
1,40
0nd
2.3
750
nd18
.0nd
6538
65-
27-2
003
1430
NSD
S62
ndnd
280
ndnd
28nd
13.0
4.0
5,90
0nd
2.1
640
nd6.
5nd
nd
427
5-27
-200
303
15N
SDS
55nd
nd27
0nd
nd28
ndnd
4.8
1,80
0nd
2.1
620
nd2.
9nd
nd43
75-
27-2
003
0325
NSD
SXnd
ndnd
260
ndnd
28nd
nd4.
03,
500
nd2.
263
0nd
ndnd
nd
468
5-27
-200
304
00N
SDS
ndnd
nd31
0nd
nd25
nd4.
811
.02,
000
nd1.
955
0nd
4.0
ndnd
478
5-27
-200
304
15N
SDS
65nd
nd27
0nd
nd25
nd4.
64.
02,
100
nd2.
057
0nd
4.3
ndnd
5310
5-27
-200
305
40N
SDS
nd31
nd30
0nd
nd31
ndnd
11.0
18,0
00nd
1.7
1,00
0nd
ndnd
120
5410
5-27
-200
306
00N
SDS
65nd
nd28
0nd
nd29
ndnd
18.0
24,0
00nd
1.8
770
ndnd
nd15
0
5711
5-28
-200
309
40N
SDS
78nd
nd36
0nd
nd21
ndnd
5.2
31,0
00nd
1.6
570
ndnd
nd28
058
115-
28-2
003
1000
NSD
S 64
ndnd
290
ndnd
34nd
nd6.
645
,000
nd2.
41,
100
ndnd
nd16
059
115-
28-2
003
1010
NSD
SX73
ndnd
290
ndnd
27nd
nd24
.031
,000
nd1.
978
0nd
ndnd
170
6212
5-28
-200
310
45N
SDS
84nd
nd28
0nd
nd22
ndnd
4.0
11,0
00nd
1.1
650
ndnd
nd82
6312
5-28
-200
311
00N
SDS
150
ndnd
240
ndnd
26nd
nd12
.025
,000
nd1.
269
0nd
ndnd
120
6713
5-28
-200
311
30N
SDS
59nd
nd25
0nd
nd29
ndnd
7.0
30,0
00nd
1.5
1,20
0nd
ndnd
140
6813
5-28
-200
311
37N
SDS
180
ndnd
320
ndnd
31nd
nd9.
020
,000
nd1.
71,
300
ndnd
nd66
6913
5-28
-200
311
42N
SDSX
ndnd
nd30
0nd
nd34
ndnd
24.0
15,0
00nd
2.7
1,00
0nd
ndnd
76
R29
R4
6-4-
2003
1205
NSD
S30
nd15
919
0nd
nd20
2.30
2.40
3.0
60,0
00nd
3.20
1,55
0nd
1.6
1.10
152
R30
R4
6-4-
2003
1209
NSD
S50
nd21
624
0nd
nd26
4.40
2.80
3.3
70,0
000.
443.
701,
720
nd1.
401.
7016
4R
31R
46-
4-20
0313
07N
SDSX
15nd
111
28nd
nd13
.52
4.60
1.0
23,5
00.8
52.
4073
0nd
.74
.79
15
Tables 6–8 41
![Page 47: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/47.jpg)
Tabl
e 6.
Co
ncen
tratio
ns o
f met
als
in q
ualit
y-co
ntro
l sam
ples
dur
ing
field
stu
dies
at t
he N
yanz
a st
udy
area
, Ash
land
, Mas
sach
uset
ts, a
nd th
e Ri
gby
Broo
k st
udy
area
, Clin
ton,
M
assa
chus
etts
.—Co
ntin
ued
[See
tabl
e 3
for
defi
nitio
ns o
f at
omic
sym
bols
(an
alyt
es).
Rep
ortin
g le
vel f
or b
old
data
was
10
times
the
nom
inal
rep
ortin
g le
vel (
tabl
e 3)
; rep
ortin
g le
vel f
or s
hade
d da
ta w
as tw
ice
the
nom
inal
rep
ortin
g le
vel.
All
conc
entr
atio
ns a
re in
mic
rogr
ams
per
liter
, exc
ept f
or c
alci
um a
nd m
agne
sium
, whi
ch a
re in
mill
igra
ms
per
liter
. Sam
ple
iden
tifie
rs a
nd s
ite n
umbe
rs p
rece
ded
by th
e le
tter
R a
re a
ssoc
iate
d w
ith th
e R
igby
B
rook
stu
dy a
rea;
oth
ers
are
from
the
Nya
nza
stud
y ar
ea. N
SDS,
nyl
on-s
cree
n di
ffus
ion
sam
pler
; NSD
SX, n
ylon
-scr
een
diff
usio
n sa
mpl
er in
itial
ly f
illed
with
aer
ated
dei
oniz
ed w
ater
; PP1
, sam
ple
from
fir
st
push
poin
t-sa
mpl
ing
loca
tion;
PP2
, sam
ple
from
sec
ond
push
poin
t-sa
mpl
ing
loca
tion;
nd,
not
det
ecte
d]
Sam
ple
iden
t-
ifier
Site
nu
mbe
r (fi
g. 8
)D
ate
Tim
e Sa
mpl
er
type
Al
SbA
sB
aB
eCd
CaCr
CoCu
FePb
Mg
Mn
Mo
Ni
VZn
NSD
S D
uplic
ates
—Co
ntin
ued
R37
R6
6-4-
2003
1419
NSD
S9.
6nd
4819
4nd
nd14
nd5.
102.
030
,700
3.7
1.90
1,22
02.
72.
700.
8816
3R
38R
66-
4-20
0314
30N
SDS
7.7
nd60
219
ndnd
200.
503.
802.
034
,700
1.7
2.70
1,32
02.
11.
60.6
916
1R
39R
66-
4-20
0314
40N
SDSX
16nd
4319
3nd
nd12
nd3.
602.
021
,800
5.3
1.60
789
2.0
4.50
.89
157
R43
R7
6-4-
2003
1527
NSD
S91
nd24
030
0nd
nd35
1.80
6.40
8.0
120,
000
nd5.
103,
100
nd1.
801.
6015
0R
44R
76-
4-20
0315
37N
SDS
58nd
280
240
ndnd
201.
602.
705.
084
,000
nd3.
102,
100
nd1.
101.
3015
0
R47
R8
6-4-
2003
1625
NSD
S66
nd26
029
0nd
nd18
1.50
4.20
5.0
88,0
001.
73.
102,
100
nd1.
201.
9020
0R
48R
86-
4-20
0316
31N
SDS
41nd
210
270
ndnd
15nd
3.10
4.0
63,0
00nd
2.20
1,40
0nd
1.10
.86
190
R49
R8
6-4-
2003
1640
NSD
SX56
nd29
028
0nd
nd17
1.20
3.70
4.0
84,0
00.8
62.
901,
700
nd1.
201.
9019
0
R55
R10
6-4-
2003
1822
NSD
Snd
nd93
240
ndnd
14nd
4.80
3.0
56,0
001.
21.
801,
300
2.7
2.00
.56
160
R56
R10
6-4-
2003
1825
NSD
Snd
nd12
025
0nd
nd17
nd4.
606.
071
,000
1.6
2.10
1,40
04.
01.
80.7
716
0
R63
R12
6-5-
2003
1045
NSD
S35
nd33
038
0nd
nd18
nd15
.00
4.0
110,
000
7.3
2.50
1,60
03.
46.
601.
2028
0R
64R
126-
5-20
0310
50N
SDS
19nd
850
480
ndnd
23nd
11.0
05.
018
0,00
01.
22.
801,
500
3.8
4.10
1.00
280
R68
R13
6-5-
2003
1145
NSD
S33
nd56
290
ndnd
6.6
nd1.
403.
012
,000
1.2
1.40
810
nd.8
3nd
170
R69
R13
6-5-
2003
1150
NSD
S32
nd40
260
ndnd
7.8
nd1.
302.
011
,000
.91
1.50
980
nd.6
7.4
812
0
R72
R14
6-5-
2003
1220
NSD
S47
nd49
250
ndnd
8.4
nd1.
705.
013
,000
2.8
1.60
1,40
0nd
.86
.95
150
R73
R14
6-5-
2003
1230
NSD
S32
nd96
210
ndnd
9.6
nd1.
603.
019
,000
1.7
2.00
1,30
0nd
.85
1.20
160
R77
R15
6-5-
2003
1325
NSD
S79
1.3
140
340
ndnd
18nd
14.0
05.
011
0,00
03.
82.
902,
400
nd3.
301.
5023
0R
78R
156-
5-20
0313
35N
SDS
160
3.3
170
350
ndnd
113.
7019
.00
5.0
190,
000
5.7
3.10
2,50
01.
26.
604.
1021
0
PPS
Fiel
d B
lank
s
212
5-27
-200
310
55nd
ndnd
2.5
ndnd
ndnd
nd2.
0nd
ndnd
ndnd
ndnd
nd39
75-
27-2
003
1445
ndnd
nd5.
6nd
ndnd
ndnd
6.0
ndnd
ndnd
ndnd
ndnd
6413
5-28
-200
311
10nd
ndnd
3nd
ndnd
ndnd
12.0
ndnd
ndnd
ndnd
ndnd
R27
46-
4-20
0311
40nd
ndnd
1.5
ndnd
ndnd
nd.3
ndnd
ndnd
ndnd
ndnd
R61
126-
5-20
0310
15nd
nd0.
714
ndnd
ndnd
nd.2
ndnd
ndnd
ndnd
ndnd
42 Field Tests of Samplers for Detection of Metals in Sediment Pore Water, Ashland and Clinton, MA, 2003
![Page 48: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/48.jpg)
Tabl
e 6.
Co
ncen
tratio
ns o
f met
als
in q
ualit
y-co
ntro
l sam
ples
dur
ing
field
stu
dies
at t
he N
yanz
a st
udy
area
, Ash
land
, Mas
sach
uset
ts, a
nd th
e Ri
gby
Broo
k st
udy
area
, Clin
ton,
M
assa
chus
etts
.—Co
ntin
ued
[See
tabl
e 3
for
defi
nitio
ns o
f at
omic
sym
bols
(an
alyt
es).
Rep
ortin
g le
vel f
or b
old
data
was
10
times
the
nom
inal
rep
ortin
g le
vel (
tabl
e 3)
; rep
ortin
g le
vel f
or s
hade
d da
ta w
as tw
ice
the
nom
inal
rep
ortin
g le
vel.
All
conc
entr
atio
ns a
re in
mic
rogr
ams
per
liter
, exc
ept f
or c
alci
um a
nd m
agne
sium
, whi
ch a
re in
mill
igra
ms
per
liter
. Sam
ple
iden
tifie
rs a
nd s
ite n
umbe
rs p
rece
ded
by th
e le
tter
R a
re a
ssoc
iate
d w
ith th
e R
igby
B
rook
stu
dy a
rea;
oth
ers
are
from
the
Nya
nza
stud
y ar
ea. N
SDS,
nyl
on-s
cree
n di
ffus
ion
sam
pler
; NSD
SX, n
ylon
-scr
een
diff
usio
n sa
mpl
er in
itial
ly f
illed
with
aer
ated
dei
oniz
ed w
ater
; PP1
, sam
ple
from
fir
st
push
poin
t-sa
mpl
ing
loca
tion;
PP2
, sam
ple
from
sec
ond
push
poin
t-sa
mpl
ing
loca
tion;
nd,
not
det
ecte
d]
Sam
ple
iden
t-
ifier
Site
nu
mbe
r (fi
g. 8
)D
ate
Tim
e Sa
mpl
er
type
Al
SbA
sB
aB
eCd
CaCr
CoCu
FePb
Mg
Mn
Mo
Ni
VZn
PPS
Sequ
entia
l and
Dup
licat
e Sa
mpl
es
Nya
nza
161
5-27
-200
310
00P
P1
130
ndnd
85nd
nd29
nd2.
913
.03,
700
nd2.
660
0nd
3.3
ndnd
171
5-27
-200
310
10P
P2
450
ndnd
77nd
nd32
nd4.
325
0.0
1,10
0nd
2.4
730
nd3.
7nd
nd
202
5-27
-200
310
45P
P1
300
ndnd
86nd
nd35
nd5.
07.
62,
600
nd2.
887
0nd
4.3
ndnd
222
5-27
-200
311
05P
P2
290
ndnd
90nd
nd38
nd7.
860
.02,
800
nd3.
086
0nd
4.9
ndnd
305
5-27
-200
312
30P
P1
850
ndnd
94nd
nd30
nd53
.09.
0nd
nd2.
162
0nd
41.0
nd16
031
55-
27-2
003
1250
PP
251
0nd
nd10
0nd
nd31
nd45
.05.
052
0nd
2.2
680
nd23
.0nd
nd
356
5-27
-200
314
00P
P1
630
ndnd
91nd
nd31
nd41
.03.
0nd
nd2.
368
0nd
25.0
ndnd
366
5-27
-200
314
10P
P2
600
6.2
nd93
ndnd
32nd
74.0
19.0
5,20
0nd
2.3
740
nd65
.0nd
140
407
5-27
-200
314
50P
P1
420
ndnd
96nd
nd31
nd29
.06.
0nd
nd2.
365
0nd
18.0
ndnd
417
5-27
-200
303
05P
P2
220
ndnd
94nd
nd30
nd11
.03.
065
0nd
2.1
640
nd6.
8nd
nd
448
5-27
-200
303
35P
P1
1,20
0nd
nd90
nd5.
030
nd44
.04.
0nd
110
2.1
630
nd32
.0nd
110
458
5-27
-200
303
45P
P2
970
ndnd
87nd
nd30
nd40
.013
0.0
ndnd
2.0
640
nd34
.0nd
71
489
5-27
-200
304
25P
P1
670
ndnd
100
ndnd
29nd
27.0
3.0
1,00
0nd
2.0
730
nd17
.0nd
5349
95-
27-2
003
0435
PP
278
0nd
nd90
ndnd
30nd
31.0
11.0
1,10
0nd
2.1
740
nd22
.0nd
nd
5110
5-27
-200
305
00P
P1
ndnd
nd29
0nd
nd35
ndnd
5.3
43,0
00nd
1.9
1,60
0nd
ndnd
nd52
105-
27-2
003
0520
PP
2nd
ndnd
270
ndnd
33nd
nd5.
962
,000
nd2.
01,
700
ndnd
nd77
5511
5-28
-200
309
15P
P1
90nd
nd12
0nd
nd35
nd4.
74.
012
,000
nd2.
685
0nd
3.5
ndnd
5611
5-28
-200
309
25P
P2
84nd
nd11
0nd
nd35
nd4.
64.
912
,000
nd2.
683
0nd
2.8
ndnd
6012
5-28
-200
310
25P
P1
ndnd
nd12
0nd
nd33
ndnd
4.6
16,0
00nd
1.3
1,10
0nd
ndnd
nd61
125-
28-2
003
1035
PP
255
ndnd
110
ndnd
31nd
10.0
13.0
4,50
0nd
1.9
780
nd4.
0nd
68
6513
5-28
-200
311
20P
P1
51nd
nd21
0nd
nd35
ndnd
3.0
23,0
00nd
2.2
1,50
0nd
ndnd
nd66
135-
28-2
003
1122
PP
167
11nd
210
ndnd
35nd
nd12
.023
,000
nd2.
21,
500
ndnd
ndnd
7014
5-28
-200
311
55P
P1
81nd
nd10
0nd
nd33
ndnd
4.0
13,0
00nd
2.3
730
ndnd
ndnd
7114
5-28
-200
312
00P
P1
80nd
nd10
0nd
nd32
ndnd
5.0
13,0
00nd
2.3
710
ndnd
ndnd
7214
5-28
-200
312
10P
P2
90nd
nd11
0nd
nd33
ndnd
38.0
12,0
00nd
2.8
520
ndnd
ndnd
7515
5-28
-200
312
40P
P1
490
ndnd
84nd
nd28
nd12
.012
.01,
700
nd2.
164
0nd
9.5
nd14
076
155-
28-2
003
1255
PP
224
0nd
nd85
ndnd
30nd
9.4
18.0
4,90
0nd
2.0
680
nd6.
6nd
nd
Tables 6–8 43
![Page 49: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/49.jpg)
Tabl
e 6.
Co
ncen
tratio
ns o
f met
als
in q
ualit
y-co
ntro
l sam
ples
dur
ing
field
stu
dies
at t
he N
yanz
a st
udy
area
, Ash
land
, Mas
sach
uset
ts, a
nd th
e Ri
gby
Broo
k st
udy
area
, Clin
ton,
M
assa
chus
etts
.—Co
ntin
ued
[See
tabl
e 3
for
defi
nitio
ns o
f at
omic
sym
bols
(an
alyt
es).
Rep
ortin
g le
vel f
or b
old
data
was
10
times
the
nom
inal
rep
ortin
g le
vel (
tabl
e 3)
; rep
ortin
g le
vel f
or s
hade
d da
ta w
as tw
ice
the
nom
inal
rep
ortin
g le
vel.
All
conc
entr
atio
ns a
re in
mic
rogr
ams
per
liter
, exc
ept f
or c
alci
um a
nd m
agne
sium
, whi
ch a
re in
mill
igra
ms
per
liter
. Sam
ple
iden
tifie
rs a
nd s
ite n
umbe
rs p
rece
ded
by th
e le
tter
R a
re a
ssoc
iate
d w
ith th
e R
igby
B
rook
stu
dy a
rea;
oth
ers
are
from
the
Nya
nza
stud
y ar
ea. N
SDS,
nyl
on-s
cree
n di
ffus
ion
sam
pler
; NSD
SX, n
ylon
-scr
een
diff
usio
n sa
mpl
er in
itial
ly f
illed
with
aer
ated
dei
oniz
ed w
ater
; PP1
, sam
ple
from
fir
st
push
poin
t-sa
mpl
ing
loca
tion;
PP2
, sam
ple
from
sec
ond
push
poin
t-sa
mpl
ing
loca
tion;
nd,
not
det
ecte
d]
Sam
ple
iden
t-
ifier
Site
nu
mbe
r (fi
g. 8
)D
ate
Tim
e Sa
mpl
er
type
Al
SbA
sB
aB
eCd
CaCr
CoCu
FePb
Mg
Mn
Mo
Ni
VZn
PPS
Sequ
entia
l and
Dup
licat
e Sa
mpl
es—
Cont
inue
d
Rigb
yR
161
6-4-
2003
0902
PP1
30nd
267
30nd
nd18
nd0.
341.
029
,800
0.71
2.40
1,51
0nd
0.65
0.73
18R
171
6-4-
2003
0920
PP1
310.
5426
636
ndnd
18nd
.35
1.0
29,7
00.6
42.
501,
490
nd.8
0.7
526
R18
16-
4-20
0306
44PP
228
nd23
625
ndnd
17nd
.65
1.0
27,9
00.6
32.
301,
380
nd.9
0.8
319
R20
26-
4-20
0310
05PP
125
nd22
724
ndnd
18nd
.97
.533
,400
.22.
301,
300
nd.6
9.6
512
R21
26-
4-20
0310
17PP
221
nd21
324
ndnd
170.
80.6
1.7
26,0
00.8
32.
0093
0nd
.79
.83
13
R23
36-
4-20
0310
50PP
151
nd68
54nd
nd18
1.60
.76
2.0
31,5
00nd
2.50
1,21
0nd
1.30
.90
20R
243
6-4-
2003
1107
PP2
44nd
8064
ndnd
212.
50.7
81.
034
,400
nd2.
901,
480
nd1.
501.
1024
R26
46-
4-20
0311
37PP
157
nd12
666
ndnd
214.
501.
302.
041
,500
nd3.
401,
270
nd1.
501.
7015
R28
46-
4-20
0312
00PP
254
nd16
264
ndnd
224.
901.
703.
060
,100
.41
3.10
1,03
0nd
1.30
2.90
14
R32
56-
4-20
0313
22PP
145
nd21
221
1nd
nd27
2.90
3.80
4.1
76,5
00nd
4.20
1,89
0nd
1.40
1.60
130
R33
56-
4-20
0313
27PP
231
nd49
39nd
nd12
nd1.
301.
012
,800
1.4
2.10
538
nd.8
7.8
76.
1
R35
66-
4-20
0313
50PP
117
nd10
789
ndnd
201.
9010
.00
1.0
51,7
004.
52.
202,
060
5.5
4.30
1.90
106
R36
66-
4-20
0314
05PP
220
nd10
883
ndnd
191.
7011
.00
12.0
47,2
003.
72.
202,
030
5.1
5.20
2.10
60
R40
76-
4-20
0314
53PP
170
nd16
073
ndnd
202.
501.
503.
354
,600
nd3.
401,
820
nd1.
101.
5012
R41
76-
4-20
0314
57PP
170
nd16
078
ndnd
191.
001.
503.
058
,000
nd3.
001,
900
nd1.
101.
2020
R42
76-
4-20
0315
05PP
277
nd11
081
ndnd
221.
401.
304.
062
,000
nd3.
402,
000
nd1.
301.
2018
R45
86-
4-20
0315
51PP
135
nd19
069
ndnd
168.
308.
302.
047
,000
.37
3.20
2,10
0nd
.68
.97
12.0
0R
468
6-4-
2003
1615
PP2
46nd
150
58nd
nd11
nd1.
602.
038
,000
.47
2.40
1,60
0nd
.54
1.20
14
R50
96-
4-20
0317
00PP
131
nd22
092
ndnd
11nd
7.30
3.0
54,0
007.
42.
102,
000
3.2
2.30
2.00
30R
519
6-4-
2003
1717
PP2
25nd
350
110
ndnd
10nd
2.60
1.0
72,0
00.9
91.
601,
800
3.1
1.10
1.30
13
R53
106-
4-20
0317
59PP
122
nd15
010
0nd
nd11
nd9.
802.
048
,000
2.5
1.80
1,40
02.
95.
001.
1049
R54
106-
4-20
0318
10PP
217
nd13
076
ndnd
9.5
nd6.
501.
049
,000
1.9
1.50
1,40
02.
43.
10.8
018
R57
116-
5-20
0309
40PP
114
nd45
034
0nd
nd21
nd36
.00
2.0
110,
000
1.3
2.90
2,30
03.
312
.00
.69
420
R58
116-
5-20
0309
50PP
213
nd43
035
0nd
nd23
nd33
.00
2.0
120,
000
.91
3.30
2,40
04.
312
.00
.73
700
44 Field Tests of Samplers for Detection of Metals in Sediment Pore Water, Ashland and Clinton, MA, 2003
![Page 50: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/50.jpg)
Tabl
e 6.
Co
ncen
tratio
ns o
f met
als
in q
ualit
y-co
ntro
l sam
ples
dur
ing
field
stu
dies
at t
he N
yanz
a st
udy
area
, Ash
land
, Mas
sach
uset
ts, a
nd th
e Ri
gby
Broo
k st
udy
area
, Clin
ton,
M
assa
chus
etts
.—Co
ntin
ued
[See
tabl
e 3
for
defi
nitio
ns o
f at
omic
sym
bols
(an
alyt
es).
Rep
ortin
g le
vel f
or b
old
data
was
10
times
the
nom
inal
rep
ortin
g le
vel (
tabl
e 3)
; rep
ortin
g le
vel f
or s
hade
d da
ta w
as tw
ice
the
nom
inal
rep
ortin
g le
vel.
All
conc
entr
atio
ns a
re in
mic
rogr
ams
per
liter
, exc
ept f
or c
alci
um a
nd m
agne
sium
, whi
ch a
re in
mill
igra
ms
per
liter
. Sam
ple
iden
tifie
rs a
nd s
ite n
umbe
rs p
rece
ded
by th
e le
tter
R a
re a
ssoc
iate
d w
ith th
e R
igby
B
rook
stu
dy a
rea;
oth
ers
are
from
the
Nya
nza
stud
y ar
ea. N
SDS,
nyl
on-s
cree
n di
ffus
ion
sam
pler
; NSD
SX, n
ylon
-scr
een
diff
usio
n sa
mpl
er in
itial
ly f
illed
with
aer
ated
dei
oniz
ed w
ater
; PP1
, sam
ple
from
fir
st
push
poin
t-sa
mpl
ing
loca
tion;
PP2
, sam
ple
from
sec
ond
push
poin
t-sa
mpl
ing
loca
tion;
nd,
not
det
ecte
d]
Sam
ple
iden
t-
ifier
Site
nu
mbe
r (fi
g. 8
)D
ate
Tim
e Sa
mpl
er
type
Al
SbA
sB
aB
eCd
CaCr
CoCu
FePb
Mg
Mn
Mo
Ni
VZn
PPS
Sequ
entia
l and
Dup
licat
e Sa
mpl
es—
Cont
inue
d
Rigb
y—Co
ntin
ued
R60
126-
5-20
0310
05PP
115
nd67
021
0nd
nd20
nd6.
908.
013
0,00
0nd
2.80
1300
1.9
2.50
0.75
ndR
6212
6-5-
2003
1030
PP2
17nd
1,20
023
0nd
nd20
nd5.
001.
016
0,00
0nd
2.80
1200
2.5
1.60
nd11
R65
136-
5-20
0311
08PP
133
nd32
46nd
nd9.
7nd
.60
2.0
10,0
006
1.90
580
nd1.
10.6
033
R66
136-
5-20
0311
20PP
133
nd33
49nd
nd9.
9nd
.58
3.0
10,0
005.
91.
9060
0nd
1.10
.62
28R
6713
6-5-
2003
1128
PP2
38nd
2743
ndnd
7.6
nd.6
51.
011
,000
2.6
1.60
790
nd.6
1.7
512
R70
146-
5-20
0312
00PP
151
nd32
51nd
nd7.
6nd
.44
4.0
12,0
006.
21.
6095
0nd
.75
.82
18R
7114
6-5-
2003
1210
PP2
43nd
3233
ndnd
7.6
nd.7
53.
010
,000
2.9
1.60
820
nd.7
1.6
6nd
R74
156-
5-20
0312
55PP
113
02
160
150
ndnd
133.
5019
.00
4.0
210,
000
.73.
8026
00nd
3.90
2.50
12R
7515
6-5-
2003
1257
PP1
140
2.1
160
160
ndnd
143.
7019
.00
3.0
210,
000
.67
3.90
2600
nd3.
902.
5017
R76
156-
5-20
0313
20PP
290
nd16
015
0nd
nd23
1.20
8.60
3.0
150,
000
nd4.
2023
00nd
2.80
1.30
14
Tables 6–8 45
![Page 51: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/51.jpg)
Tabl
e 7.
Co
ncen
tratio
ns o
f met
als
dete
cted
in s
ampl
es fr
om th
e N
yanz
a st
udy
area
, Ash
land
, Mas
sach
uset
ts.—
Cont
inue
d
[See
tabl
e 3
for
defi
nitio
ns o
f at
omic
sym
bols
(an
alyt
es).
All
conc
entr
atio
ns a
re in
mic
rogr
ams
per
liter
, exc
ept f
or c
alci
um a
nd m
agne
sium
, whi
ch a
re in
mill
igra
ms
per
liter
. Con
cent
ratio
ns in
bol
d ty
pe
exce
ed th
e pr
ojec
t act
ion
limit.
Sha
ded
data
rep
rese
nt s
ampl
es th
at w
ere
dilu
ted
10:1
due
to s
ampl
er in
terf
eren
ces.
Rep
ortin
g le
vels
for
thos
e sa
mpl
es a
re 1
0 tim
es th
e no
min
al r
epor
ting
leve
ls (
tabl
e 3)
. N
SDS,
nyl
on-s
cree
n di
ffus
ion
sam
pler
; NSD
SX, n
ylon
-scr
een
diff
usio
n sa
mpl
er in
itial
ly f
illed
with
aer
ated
dei
oniz
ed w
ater
; PP1
, sam
ple
from
fir
st p
ushp
oint
-sam
plin
g lo
catio
n; P
P2, s
ampl
e fr
om s
econ
d pu
shpo
int-
sam
plin
g lo
catio
n; n
d, n
ot d
etec
ted]
Sam
ple
num
ber
Site
nu
mbe
r (fi
g. 8
)D
ate
Tim
eSa
mpl
er
type
Al
SbA
sB
aB
eCd
CaCr
CoCu
FePb
Mg
Mn
Mo
Ni
VZn
13
5-13
-200
312
05N
SDS
15nd
0.78
270
ndnd
15nd
0.3
2.0
770
0.37
1.3
290
nd1.
40.
2282
26
5-13
-200
312
25N
SDS
45nd
nd17
00.
27nd
25nd
17.0
2.0
3,30
0nd
1.9
550
nd10
.0nd
433
95-
13-2
003
1240
NSD
S17
nd.5
300
ndnd
19nd
.71.
02,
900
nd1.
541
0nd
1.7
nd78
412
5-13
-200
312
50N
SDS
38nd
.74
220
ndnd
8.8
nd.2
3.0
5,50
01.
9.7
250
nd1.
1nd
200
515
5-13
-200
313
05N
SDS
32nd
nd23
0.2
4nd
190.
802.
72.
05,
500
nd1.
651
0nd
3.2
nd88
63
5-15
-200
311
45N
SDS
14nd
nd22
0nd
nd14
nd.4
1.0
2,80
0nd
1.3
290
nd2.
0nd
327
65-
15-2
003
1155
NSD
S 14
ndnd
230
ndnd
25nd
.93.
07,
300
nd1.
758
0nd
2.4
nd48
89
5-15
-200
312
10N
SDS
12nd
nd24
0nd
nd16
nd.6
1.0
5,10
0nd
1.4
350
nd1.
9nd
529
125-
15-2
003
1220
NSD
S nd
ndnd
300
ndnd
27nd
nd2.
533
,000
nd1.
51,
100
ndnd
nd17
010
155-
15-2
003
1230
NSD
S 57
ndnd
320
ndnd
29nd
2.4
2.0
8,10
0nd
2.1
700
nd3.
4nd
80
113
5-19
-200
311
40N
SDS
ndnd
nd29
0nd
nd24
ndnd
nd3,
000
nd1.
855
0nd
ndnd
nd12
65-
19-2
003
1150
NSD
S 78
ndnd
310
ndnd
30nd
19.0
11.0
1,30
0nd
2.1
690
nd5.
9nd
6613
95-
19-2
003
1200
NSD
S nd
ndnd
270
ndnd
19nd
nd6.
73,
200
nd1.
541
0nd
ndnd
nd14
125-
19-2
003
1210
NSD
S 51
ndnd
290
ndnd
31nd
nd3.
429
,000
nd1.
499
0nd
ndnd
140
1515
5-19
-200
312
20N
SDS
ndnd
nd25
0nd
nd20
ndnd
2.4
7,50
0nd
1.4
460
ndnd
ndnd
161
5-27
-200
310
00PP
113
0nd
nd85
ndnd
29nd
2.9
13.0
3,70
0nd
2.6
600
nd3.
3nd
nd17
15-
27-2
003
1010
PP2
450
ndnd
77nd
nd32
nd4.
325
0.0
1,10
0nd
2.4
730
nd3.
7nd
nd18
15-
27-2
003
1025
NSD
S10
0nd
nd26
0nd
nd29
ndnd
4.8
5,00
0nd
2.4
750
ndnd
nd65
191
5-27
-200
310
35N
SDS
130
ndnd
260
ndnd
31nd
5.0
3.0
590
nd3.
071
0nd
ndnd
6720
25-
27-2
003
1045
PP1
300
ndnd
86nd
nd35
nd5.
07.
62,
600
nd2.
887
0nd
4.3
ndnd
212
5-27
-200
310
55B
LA
NK
ndnd
nd2.
5nd
ndnd
ndnd
2.0
ndnd
ndnd
ndnd
ndnd
222
5-27
-200
311
05PP
229
0nd
nd90
ndnd
38nd
7.8
60.0
2,80
0nd
3.0
860
nd4.
9nd
nd23
25-
27-2
003
1115
NSD
S26
0nd
nd19
0nd
nd37
nd2.
13.
093
0nd
2.9
830
nd2.
3nd
nd24
35-
27-2
003
1135
PP1
290
ndnd
88nd
nd31
nd33
.05.
03,
200
nd2.
274
0nd
19.0
nd52
253
5-27
-200
311
45N
SDS
54nd
nd27
0nd
nd31
ndnd
5.0
3,50
0nd
2.2
650
ndnd
ndnd
264
5-27
-200
311
50PP
157
0nd
nd85
ndnd
31nd
41.0
6.0
1,00
0nd
2.3
670
nd25
.0nd
nd27
45-
27-2
003
1200
PP2
460
ndnd
98nd
nd31
nd17
.021
.055
0nd
2.3
680
nd10
.0nd
nd28
45-
27-2
003
1210
NSD
S90
ndnd
290
ndnd
34nd
17.0
4.0
1,50
0nd
2.5
720
nd5.
2nd
nd29
45-
27-2
003
1220
NSD
Snd
28nd
270
ndnd
32nd
nd7.
08,
700
nd2.
467
0nd
5.0
ndnd
305
5-27
-200
312
30PP
185
0nd
nd94
ndnd
30nd
53.0
9.0
ndnd
2.1
620
nd41
.0nd
160
46 Field Tests of Samplers for Detection of Metals in Sediment Pore Water, Ashland and Clinton, MA, 2003
![Page 52: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/52.jpg)
Tabl
e 7.
Co
ncen
tratio
ns o
f met
als
dete
cted
in s
ampl
es fr
om th
e N
yanz
a st
udy
area
, Ash
land
, Mas
sach
uset
ts.—
Cont
inue
d
[See
tabl
e 3
for
defi
nitio
ns o
f at
omic
sym
bols
(an
alyt
es).
All
conc
entr
atio
ns a
re in
mic
rogr
ams
per
liter
, exc
ept f
or c
alci
um a
nd m
agne
sium
, whi
ch a
re in
mill
igra
ms
per
liter
. Con
cent
ratio
ns in
bol
d ty
pe
exce
ed th
e pr
ojec
t act
ion
limit.
Sha
ded
data
rep
rese
nt s
ampl
es th
at w
ere
dilu
ted
10:1
due
to s
ampl
er in
terf
eren
ces.
Rep
ortin
g le
vels
for
thos
e sa
mpl
es a
re 1
0 tim
es th
e no
min
al r
epor
ting
leve
ls (
tabl
e 3)
. N
SDS,
nyl
on-s
cree
n di
ffus
ion
sam
pler
; NSD
SX, n
ylon
-scr
een
diff
usio
n sa
mpl
er in
itial
ly f
illed
with
aer
ated
dei
oniz
ed w
ater
; PP1
, sam
ple
from
fir
st p
ushp
oint
-sam
plin
g lo
catio
n; P
P2, s
ampl
e fr
om s
econ
d pu
shpo
int-
sam
plin
g lo
catio
n; n
d, n
ot d
etec
ted]
Sam
ple
num
ber
Site
nu
mbe
r (fi
g. 8
)D
ate
Tim
eSa
mpl
er
type
Al
SbA
sB
aB
eCd
CaCr
CoCu
FePb
Mg
Mn
Mo
Ni
VZn
315
5-27
-200
312
50PP
251
0nd
nd10
0nd
nd31
nd45
.05.
052
0nd
2.2
680
nd23
.0nd
nd32
55-
27-2
003
110
NSD
S93
ndnd
290
ndnd
31nd
23.0
29.0
1,80
0nd
2.3
660
nd8.
4nd
nd33
55-
27-2
003
125
NSD
S11
0nd
nd27
0nd
nd31
nd25
.06.
01,
300
nd2.
369
0nd
8.5
ndnd
345
5-27
-200
313
5N
SDSX
210
ndnd
300
ndnd
31nd
17.0
8.0
740
nd2.
369
0nd
8.3
nd82
356
5-27
-200
314
00PP
163
0nd
nd91
ndnd
31nd
41.0
3.0
ndnd
2.3
680
nd25
.0nd
nd
366
5-27
-200
314
10PP
260
06.
2nd
93nd
nd32
nd74
.019
.05,
200
nd2.
374
0nd
65.0
nd14
037
65-
27-2
003
1420
NSD
S11
0nd
nd28
0nd
nd32
nd43
.04.
01,
400
nd2.
375
0nd
18.0
nd65
386
5-27
-200
314
30N
SDS
62nd
nd28
0nd
nd28
nd13
.04.
05,
900
nd2.
164
0nd
6.5
ndnd
397
5-27
-200
314
45B
LA
NK
ndnd
nd5.
6nd
ndnd
ndnd
6.0
ndnd
ndnd
ndnd
ndnd
407
5-27
-200
314
50PP
142
0nd
nd96
ndnd
31nd
29.0
6.0
ndnd
2.3
650
nd18
.0nd
nd
417
5-27
-200
330
5PP
222
0nd
nd94
ndnd
30nd
11.0
3.0
650
nd2.
164
0nd
6.8
ndnd
427
5-27
-200
331
5N
SDS
55nd
nd27
0nd
nd28
ndnd
4.8
1,80
0nd
2.1
620
nd2.
9nd
nd43
75-
27-2
003
325
NSD
SXnd
ndnd
260
ndnd
28nd
nd4.
03,
500
nd2.
263
0nd
ndnd
nd44
85-
27-2
003
335
PP1
1,20
0nd
nd90
nd5.
030
nd44
.04.
0nd
110
2.1
630
nd32
.0nd
110
458
5-27
-200
334
5PP
297
0nd
nd87
ndnd
30nd
40.0
130.
0nd
nd2.
064
0nd
34.0
nd71
468
5-27
-200
340
0N
SDS
ndnd
nd31
0nd
nd25
nd4.
811
.02,
000
nd1.
955
0nd
4.0
ndnd
478
5-27
-200
341
5N
SDS
65nd
nd27
0nd
nd25
nd4.
64.
02,
100
nd2.
057
0nd
4.3
ndnd
489
5-27
-200
342
5PP
167
0nd
nd10
0nd
nd29
nd27
.03.
010
00nd
2.0
730
nd17
.0nd
5349
95-
27-2
003
435
PP2
780
ndnd
90nd
nd30
nd31
.011
.01,
100
nd2.
174
0nd
22.0
ndnd
509
5-27
-200
344
5N
SDS
ndnd
nd24
0nd
nd17
ndnd
3.0
6,10
0nd
1.4
410
ndnd
ndnd
5110
5-27
-200
350
0PP
1nd
ndnd
290
ndnd
35nd
nd5.
343
,000
nd1.
91,
600
ndnd
ndnd
5210
5-27
-200
352
0PP
2nd
ndnd
270
ndnd
33nd
nd5.
962
,000
nd2.
01,
700
ndnd
nd77
5310
5-27
-200
354
0N
SDS
nd31
nd30
0nd
nd31
ndnd
11.0
18,0
00nd
1.7
1,00
0nd
ndnd
120
5410
5-27
-200
360
0N
SDS
65nd
nd28
0nd
nd29
ndnd
18.0
24,0
00nd
1.8
770
ndnd
nd15
055
115-
28-2
003
915
PP1
90nd
nd12
0nd
nd35
nd4.
74.
012
,000
nd2.
685
0nd
3.5
ndnd
5611
5-28
-200
392
5PP
284
ndnd
110
ndnd
35nd
4.6
4.9
12,0
00nd
2.6
830
nd2.
8nd
nd57
115-
28-2
003
940
NSD
S78
ndnd
360
ndnd
21nd
nd5.
231
,000
nd1.
657
0nd
ndnd
280
5811
5-28
-200
310
00N
SDS
64nd
nd29
0nd
nd34
ndnd
6.6
45,0
00nd
2.4
1,10
0nd
ndnd
160
5911
5-28
-200
310
10N
SDSX
73nd
nd29
0nd
nd27
ndnd
24.0
31,0
00nd
1.9
780
ndnd
nd17
060
125-
28-2
003
1025
PP1
ndnd
nd12
0nd
nd33
ndnd
4.6
16,0
00nd
1.3
1,10
0nd
ndnd
nd
Tables 6–8 47
![Page 53: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/53.jpg)
Tabl
e 7.
Co
ncen
tratio
ns o
f met
als
dete
cted
in s
ampl
es fr
om th
e N
yanz
a st
udy
area
, Ash
land
, Mas
sach
uset
ts.—
Cont
inue
d
[See
tabl
e 3
for
defi
nitio
ns o
f at
omic
sym
bols
(an
alyt
es).
All
conc
entr
atio
ns a
re in
mic
rogr
ams
per
liter
, exc
ept f
or c
alci
um a
nd m
agne
sium
, whi
ch a
re in
mill
igra
ms
per
liter
. Con
cent
ratio
ns in
bol
d ty
pe
exce
ed th
e pr
ojec
t act
ion
limit.
Sha
ded
data
rep
rese
nt s
ampl
es th
at w
ere
dilu
ted
10:1
due
to s
ampl
er in
terf
eren
ces.
Rep
ortin
g le
vels
for
thos
e sa
mpl
es a
re 1
0 tim
es th
e no
min
al r
epor
ting
leve
ls (
tabl
e 3)
. N
SDS,
nyl
on-s
cree
n di
ffus
ion
sam
pler
; NSD
SX, n
ylon
-scr
een
diff
usio
n sa
mpl
er in
itial
ly f
illed
with
aer
ated
dei
oniz
ed w
ater
; PP1
, sam
ple
from
fir
st p
ushp
oint
-sam
plin
g lo
catio
n; P
P2, s
ampl
e fr
om s
econ
d pu
shpo
int-
sam
plin
g lo
catio
n; n
d, n
ot d
etec
ted]
Sam
ple
num
ber
Site
nu
mbe
r (fi
g. 8
)D
ate
Tim
eSa
mpl
er
type
Al
SbA
sB
aB
eCd
CaCr
CoCu
FePb
Mg
Mn
Mo
Ni
VZn
6112
5-28
-200
310
35PP
255
ndnd
110
ndnd
31nd
10.0
13.0
4,50
0nd
1.9
780
nd4.
0nd
6862
125-
28-2
003
1045
NSD
S84
ndnd
280
ndnd
22nd
nd4.
011
,000
nd1.
165
0nd
ndnd
8263
125-
28-2
003
1100
NSD
S15
0nd
nd24
0nd
nd26
ndnd
12.0
25,0
00nd
1.2
690
ndnd
nd12
064
135-
28-2
003
1110
BL
AN
Knd
ndnd
3nd
ndnd
ndnd
12.0
ndnd
ndnd
ndnd
ndnd
6513
5-28
-200
311
20PP
151
ndnd
210
ndnd
35nd
nd3.
023
,000
nd2.
21,
500
ndnd
ndnd
6613
5-28
-200
311
22PP
167
11nd
210
ndnd
35nd
nd12
.023
,000
nd2.
21,
500
ndnd
ndnd
6713
5-28
-200
311
30N
SDS
59nd
nd25
0nd
nd29
ndnd
7.0
30,0
00nd
1.5
1,20
0nd
ndnd
140
6813
5-28
-200
311
37N
SDS
180
ndnd
320
ndnd
31nd
nd9.
020
,000
nd1.
71,
300
ndnd
nd66
6913
5-28
-200
311
42N
SDSX
ndnd
nd30
0nd
nd34
ndnd
24.0
15,0
00nd
2.7
1,00
0nd
ndnd
7670
145-
28-2
003
1155
PP1
81nd
nd10
0nd
nd33
ndnd
4.0
13,0
00nd
2.3
730
ndnd
ndnd
7114
5-28
-200
312
00PP
180
ndnd
100
ndnd
32nd
nd5.
013
,000
nd2.
371
0nd
ndnd
nd72
145-
28-2
003
1210
PP2
90nd
nd11
0nd
nd33
ndnd
38.0
12,0
00nd
2.8
520
ndnd
ndnd
7314
5-28
-200
312
20N
SDS
51nd
nd31
0nd
nd30
ndnd
3.0
9,90
0nd
2.1
780
ndnd
ndnd
7414
5-28
-200
312
30N
SDS
ndnd
nd29
0nd
nd29
ndnd
11.0
6,40
0nd
2.0
570
ndnd
ndnd
7515
5-28
-200
312
40PP
149
0nd
nd84
ndnd
28nd
12.0
12.0
1,70
0nd
2.1
640
nd9.
5nd
140
7615
5-28
-200
312
55PP
224
0nd
nd85
ndnd
30nd
9.4
18.0
4,90
0nd
2.0
680
nd6.
6nd
nd77
155-
28-2
003
110
NSD
S78
ndnd
310
ndnd
28nd
2.0
3.0
2,70
0nd
2.1
620
ndnd
ndnd
48 Field Tests of Samplers for Detection of Metals in Sediment Pore Water, Ashland and Clinton, MA, 2003
![Page 54: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/54.jpg)
Tabl
e 8.
Co
ncen
tratio
ns o
f met
als
dete
cted
in s
ampl
es fr
om R
igby
Bro
ok s
tudy
are
a, C
linto
n, M
assa
chus
etts
.—Co
ntin
ued
[See
tabl
e 3
for
defi
nitio
ns o
f at
omic
sym
bols
(an
alyt
es).
All
conc
entr
atio
ns a
re in
mic
rogr
ams
per
liter
, exc
ept f
or c
alci
um a
nd m
agne
sium
, whi
ch a
re in
mill
igra
ms
per
liter
. Con
cent
ratio
ns in
bol
d ty
pe
exce
ed th
e pr
ojec
t act
ion
limit.
Sha
ded
data
rep
rese
nt s
ampl
es th
at w
ere
dilu
ted
2:1
due
to s
ampl
er in
terf
eren
ces.
Rep
ortin
g le
vels
for
thos
e sa
mpl
es a
re tw
o tim
es th
e no
min
al r
epor
ting
leve
ls (
tabl
e 3)
. NSD
S,
nylo
n-sc
reen
dif
fusi
on s
ampl
er; N
SDSX
, nyl
on-s
cree
n di
ffus
ion
sam
pler
initi
ally
fill
ed w
ith a
erat
ed d
eion
ized
wat
er; P
P1, s
ampl
e fr
om f
irst
pus
hpoi
nt-s
ampl
ing
loca
tion;
PP2
, sam
ple
from
sec
ond
push
poin
t-sa
mpl
ing
loca
tion;
nd,
not
det
ecte
d]
Sam
ple
num
ber
Site
nu
mbe
r (fi
g. 8
)D
ate
Tim
e Sa
mpl
er
type
Al
SbA
sB
aB
eCd
CaCr
CoCu
FePb
Mg
Mn
Mo
Ni
VZn
R1
35-
21-2
003
1040
NSD
S23
nd33
265
ndnd
6.6
nd1.
503.
021
,900
0.84
1.00
548
nd0.
920.
2419
9R
26
5-21
-200
310
55N
SDS
39nd
1832
3nd
nd7.
3nd
2.60
4.0
12,4
0018
1.00
615
1.0
1.60
.73
283
R3
95-
21-2
003
1105
NSD
S32
nd37
371
ndnd
10nd
5.50
4.0
27,5
007.
81.
401,
400
1.6
3.00
1.00
292
R4
125-
21-2
003
1115
NSD
S36
0.52
6831
7nd
nd15
nd11
.00
4.0
44,3
009.
12.
001,
670
2.7
4.30
1.10
243
R5
155-
21-2
003
1130
NSD
S42
1.00
3225
1nd
nd3.
8nd
3.20
5.0
19,9
0011
.75
552
nd1.
70.8
522
8
R6
35-
23-2
003
1010
NSD
S14
.51
6622
5nd
nd13
nd2.
203.
054
,300
.37
1.90
1,14
0.6
.87
.38
157
R7
65-
23-2
003
1020
NSD
S43
nd30
251
ndnd
9.4
nd3.
204.
022
,100
161.
2085
72.
22.
10.8
720
7R
89
5-23
-200
310
35N
SDS
50nd
3722
8nd
nd5.
4nd
3.30
4.0
14,9
0035
.99
604
1.3
2.00
1.20
212
R9
125-
23-2
003
1045
NSD
S30
nd14
733
5nd
nd22
0.80
17.0
06.
084
,800
6.4
2.90
2,51
06.
06.
401.
6020
9R
1015
5-23
-200
310
55N
SDS
82.9
810
322
1nd
nd5.
5.6
15.
704.
042
,700
121.
1088
4.6
2.30
1.70
171
R11
35-
28-2
003
1600
NSD
S17
.710
412
0nd
nd19
nd1.
402.
066
,500
.31
2.70
1,62
0.6
.93
.43
80R
126
5-28
-200
316
15N
SDS
30nd
2514
1nd
nd16
nd5.
602.
035
,500
8.4
2.10
1,59
02.
53.
10.9
213
3R
139
5-28
-200
316
25N
SDS
63.5
154
123
ndnd
8.2
nd3.
6021
.026
,500
181.
3081
01.
72.
001.
3014
2R
1412
5-28
-200
316
35N
SDS
31nd
246
222
ndnd
19nd
14.0
02.
089
,300
7.1
2.90
1,78
03.
06.
301.
2018
8R
1515
5-28
-200
316
50N
SDS
64.8
531
016
5nd
nd18
.80
12.0
02.
098
,600
122.
602,
800
1.1
3.30
1.80
123
R16
16-
4-20
0390
2PP
130
nd26
730
ndnd
18nd
.34
1.0
29,8
00.7
12.
401,
510
nd.6
5.7
318
R17
16-
4-20
0392
0PP
131
.54
266
36nd
nd18
nd.3
51.
029
,700
.64
2.50
1,49
0nd
.80
.75
26R
181
6-4-
2003
644
PP2
28nd
236
25nd
nd17
nd.6
51.
027
,900
.63
2.30
1,38
0nd
.90
.83
19R
191
6-4-
2003
947
NSD
S29
.52
209
201
ndnd
31.5
49.
202.
068
,600
.53
3.90
2,33
02.
13.
001.
6016
2R
202
6-4-
2003
1005
PP1
25nd
227
24nd
nd18
nd.9
7.5
33,4
00.2
2.30
1,30
0nd
.69
.65
12
R21
26-
4-20
0310
17PP
221
nd21
324
ndnd
17.8
0.6
1.7
26,0
00.8
32.
0093
0nd
.79
.83
13R
222
6-4-
2003
1020
NSD
S28
nd23
815
4nd
nd17
.93
3.10
4.6
30,0
001.
52.
101,
020
nd2.
10.9
714
3R
233
6-4-
2003
1050
PP1
51nd
6854
ndnd
181.
60.7
62.
031
,500
nd2.
501,
210
nd1.
30.9
020
R24
36-
4-20
0311
07PP
244
nd80
64nd
nd21
2.50
.78
1.0
34,4
00nd
2.90
1,48
0nd
1.50
1.10
24R
253
6-4-
2003
1125
NSD
S26
nd19
520
0nd
nd24
3.60
2.70
2.0
79,3
00nd
3.40
1,84
0nd
1.40
1.50
139
R26
46-
4-20
0311
37PP
157
nd12
666
ndnd
214.
501.
302.
041
,500
nd3.
401,
270
nd1.
501.
7015
R27
46-
4-20
0311
40B
LA
NK
ndnd
nd1.
5nd
ndnd
ndnd
.3nd
ndnd
ndnd
ndnd
ndR
284
6-4-
2003
1200
PP2
54nd
162
64nd
nd22
4.90
1.70
3.0
60,1
00.4
13.
101,
030
nd1.
302.
9014
R29
46-
4-20
0312
05N
SDS
30nd
159
190
ndnd
202.
302.
403.
060
,000
nd3.
201,
550
nd1.
61.
1015
2R
304
6-4-
2003
1209
NSD
S50
nd21
624
0nd
nd26
4.40
2.80
3.3
70,0
00.4
43.
701,
720
nd1.
401.
7016
4
Tables 6–8 49
![Page 55: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/55.jpg)
Tabl
e 8.
Co
ncen
tratio
ns o
f met
als
dete
cted
in s
ampl
es fr
om R
igby
Bro
ok s
tudy
are
a, C
linto
n, M
assa
chus
etts
.—Co
ntin
ued
[See
tabl
e 3
for
defi
nitio
ns o
f at
omic
sym
bols
(an
alyt
es).
All
conc
entr
atio
ns a
re in
mic
rogr
ams
per
liter
, exc
ept f
or c
alci
um a
nd m
agne
sium
, whi
ch a
re in
mill
igra
ms
per
liter
. Con
cent
ratio
ns in
bol
d ty
pe
exce
ed th
e pr
ojec
t act
ion
limit.
Sha
ded
data
rep
rese
nt s
ampl
es th
at w
ere
dilu
ted
2:1
due
to s
ampl
er in
terf
eren
ces.
Rep
ortin
g le
vels
for
thos
e sa
mpl
es a
re tw
o tim
es th
e no
min
al r
epor
ting
leve
ls (
tabl
e 3)
. NSD
S,
nylo
n-sc
reen
dif
fusi
on s
ampl
er; N
SDSX
, nyl
on-s
cree
n di
ffus
ion
sam
pler
initi
ally
fill
ed w
ith a
erat
ed d
eion
ized
wat
er; P
P1, s
ampl
e fr
om f
irst
pus
hpoi
nt-s
ampl
ing
loca
tion;
PP2
, sam
ple
from
sec
ond
push
poin
t-sa
mpl
ing
loca
tion;
nd,
not
det
ecte
d]
Sam
ple
num
ber
Site
nu
mbe
r (fi
g. 8
)D
ate
Tim
e Sa
mpl
er
type
Al
SbA
sB
aB
eCd
CaCr
CoCu
FePb
Mg
Mn
Mo
Ni
VZn
R31
46-
4-20
0313
07N
SDSX
15nd
111
28nd
nd13
0.52
4.60
1.0
23,5
000.
852.
4073
0nd
0.74
0.79
15R
325
6-4-
2003
1322
PP1
45nd
212
211
ndnd
272.
903.
804.
176
,500
nd4.
201,
890
nd1.
401.
6013
0R
335
6-4-
2003
1327
PP2
31nd
4939
ndnd
12nd
1.30
1.0
12,8
001.
42.
1053
8nd
.87
.87
6.1
R34
56-
4-20
0313
30N
SDS
18nd
2816
4nd
nd16
nd2.
502.
07,
840
.64
2.40
583
nd1.
80.7
048
R35
66-
4-20
0313
50PP
117
nd10
789
ndnd
201.
9010
.00
1.0
51,7
004.
52.
202,
060
5.5
4.30
1.90
106
R36
66-
4-20
0314
05PP
220
nd10
883
ndnd
191.
7011
.00
12.0
47,2
003.
72.
202,
030
5.1
5.20
2.10
60R
376
6-4-
2003
1419
NSD
S9.
6nd
4819
4nd
nd14
nd5.
102.
030
,700
3.7
1.90
1,22
02.
7nd
.88
163
R38
66-
4-20
0314
30N
SDS
7.7
nd60
219
ndnd
20.5
03.
802.
034
,700
1.7
2.70
1,32
02.
11.
60.6
916
1R
396
6-4-
2003
1440
NSD
SX16
nd43
193
ndnd
12nd
3.60
2.0
21,8
005.
31.
6078
92.
04.
50.8
915
7R
407
6-4-
2003
1453
PP1
70nd
160
73nd
nd20
2.50
1.50
3.3
54,6
00nd
3.40
1,82
0nd
1.10
1.50
12
R41
76-
4-20
0314
57PP
170
nd16
078
ndnd
191.
001.
503.
058
,000
nd3.
001,
900
nd1.
101.
2020
R42
76-
4-20
0315
05PP
277
nd11
081
ndnd
221.
401.
304.
062
,000
nd3.
402,
000
nd1.
301.
2018
R43
76-
4-20
0315
27N
SDS
91nd
240
300
ndnd
351.
806.
408.
012
0,00
0nd
5.10
3,10
0nd
1.80
1.60
150
R44
76-
4-20
0315
37N
SDS
58nd
280
240
ndnd
201.
602.
705.
084
,000
nd3.
102,
100
nd1.
101.
3015
0R
458
6-4-
2003
1551
PP1
35nd
190
69nd
nd16
8.30
8.30
2.0
47,0
00.3
73.
202,
100
nd.6
8.9
712
.00
R46
86-
4-20
0316
15PP
246
nd15
058
ndnd
11nd
1.60
2.0
38,0
00.4
72.
401,
600
nd.5
41.
2014
R47
86-
4-20
0316
25N
SDS
66nd
260
290
ndnd
181.
504.
205.
088
,000
1.7
3.10
2,10
0nd
1.20
1.90
200
R48
86-
4-20
0316
31N
SDS
41nd
210
270
ndnd
15nd
3.10
4.0
63,0
00nd
2.20
1,40
0nd
1.10
.86
190
R49
86-
4-20
0316
40N
SDSX
56nd
290
280
ndnd
171.
203.
704.
084
,000
.86
2.90
1,70
0nd
1.20
1.90
190
R50
96-
4-20
0317
00PP
131
nd22
092
ndnd
11nd
7.30
3.0
54,0
007.
42.
102,
000
3.2
2.30
2.00
30
R51
96-
4-20
0317
17PP
225
nd35
011
0nd
nd10
nd2.
601.
072
,000
.99
1.60
1,80
03.
11.
101.
3013
R52
96-
4-20
0317
30N
SDS
31nd
5839
0nd
nd9.
9nd
4.70
5.0
38,0
005.
71.
601,
200
1.8
2.10
1.60
290
R53
106-
4-20
0317
59PP
122
nd15
010
0nd
nd11
nd9.
802.
048
,000
2.5
1.80
1,40
02.
95.
001.
1049
R54
106-
4-20
0318
10PP
217
nd13
076
ndnd
9.5
nd6.
501.
049
,000
1.9
1.50
1,40
02.
43.
10.8
018
R55
106-
4-20
0318
22N
SDS
ndnd
9324
0nd
nd14
nd4.
803.
056
,000
1.2
1.80
1,30
02.
72.
00.5
616
0
R56
106-
4-20
0318
25N
SDS
ndnd
120
250
ndnd
17nd
4.60
6.0
71,0
001.
62.
101,
400
4.0
1.80
.77
160
R57
116-
5-20
0394
0PP
114
nd45
034
0nd
nd21
nd36
.00
2.0
110,
000
1.3
2.90
2,30
03.
312
.00
.69
420
R58
116-
5-20
0395
0PP
213
nd43
035
0nd
nd23
nd33
.00
2.0
120,
000
.91
3.30
2,40
04.
312
.00
.73
700
R59
116-
5-20
0310
00N
SDS
15nd
220
380
ndnd
16nd
12.0
04.
075
,000
22.
201,
500
4.1
4.10
.76
260
R60
126-
5-20
0310
05PP
115
nd67
021
0nd
nd20
nd6.
908.
013
0,00
0nd
2.80
1,30
01.
92.
50.7
5nd
50 Field Tests of Samplers for Detection of Metals in Sediment Pore Water, Ashland and Clinton, MA, 2003
![Page 56: Field Tests of Nylon-Screen Diffusion Samplers and Pushpoint ...](https://reader036.fdocuments.net/reader036/viewer/2022081513/5867b6f41a28abcd408bdeaf/html5/thumbnails/56.jpg)
Tabl
e 8.
Co
ncen
tratio
ns o
f met
als
dete
cted
in s
ampl
es fr
om R
igby
Bro
ok s
tudy
are
a, C
linto
n, M
assa
chus
etts
.—Co
ntin
ued
[See
tabl
e 3
for
defi
nitio
ns o
f at
omic
sym
bols
(an
alyt
es).
All
conc
entr
atio
ns a
re in
mic
rogr
ams
per
liter
, exc
ept f
or c
alci
um a
nd m
agne
sium
, whi
ch a
re in
mill
igra
ms
per
liter
. Con
cent
ratio
ns in
bol
d ty
pe
exce
ed th
e pr
ojec
t act
ion
limit.
Sha
ded
data
rep
rese
nt s
ampl
es th
at w
ere
dilu
ted
2:1
due
to s
ampl
er in
terf
eren
ces.
Rep
ortin
g le
vels
for
thos
e sa
mpl
es a
re tw
o tim
es th
e no
min
al r
epor
ting
leve
ls (
tabl
e 3)
. NSD
S,
nylo
n-sc
reen
dif
fusi
on s
ampl
er; N
SDSX
, nyl
on-s
cree
n di
ffus
ion
sam
pler
initi
ally
fill
ed w
ith a
erat
ed d
eion
ized
wat
er; P
P1, s
ampl
e fr
om f
irst
pus
hpoi
nt-s
ampl
ing
loca
tion;
PP2
, sam
ple
from
sec
ond
push
poin
t-sa
mpl
ing
loca
tion;
nd,
not
det
ecte
d]
Sam
ple
num
ber
Site
nu
mbe
r (fi
g. 8
)D
ate
Tim
e Sa
mpl
er
type
Al
SbA
sB
aB
eCd
CaCr
CoCu
FePb
Mg
Mn
Mo
Ni
VZn
R61
126-
5-20
0310
15B
LA
NK
ndnd
0.71
4nd
ndnd
ndnd
0.2
ndnd
ndnd
ndnd
ndnd
R62
126-
5-20
0310
30PP
217
nd1,
200
230
ndnd
20nd
5.00
1.0
160,
000
nd2.
801,
200
2.5
1.60
nd11
R63
126-
5-20
0310
45N
SDS
35nd
330
380
ndnd
18nd
15.0
04.
011
0,00
07.
32.
501,
600
3.4
6.60
1.20
280
R64
126-
5-20
0310
50N
SDS
19nd
850
480
ndnd
23nd
11.0
05.
018
0,00
01.
22.
801,
500
3.8
4.10
1.00
280
R65
136-
5-20
0311
08PP
133
nd32
46nd
nd9.
7nd
.60
2.0
10,0
006
1.90
580
nd1.
10.6
033
R66
136-
5-20
0311
20PP
133
nd33
49nd
nd9.
9nd
.58
3.0
10,0
005.
91.
9060
0nd
1.10
.62
28R
6713
6-5-
2003
1128
PP2
38nd
2743
ndnd
7.6
nd.6
51.
011
,000
2.6
1.60
790
nd.6
1.7
512
R68
136-
5-20
0311
45N
SDS
33nd
5629
0nd
nd6.
6nd
1.40
3.0
12,0
001.
21.
4081
0nd
.83
nd17
0R
6913
6-5-
2003
1150
NSD
S32
nd40
260
ndnd
7.8
nd1.
302.
011
,000
.91
1.50
980
nd.6
7.4
812
0R
7014
6-5-
2003
1200
PP1
51nd
3251
ndnd
7.6
nd.4
44.
012
,000
6.2
1.60
950
nd.7
5.8
218
R71
146-
5-20
0312
10PP
243
nd32
33nd
nd7.
6nd
.75
3.0
10,0
002.
91.
6082
0nd
.71
.66
ndR
7214
6-5-
2003
1220
NSD
S47
nd49
250
ndnd
8.4
nd1.
705.
013
,000
2.8
1.60
1,40
0nd
.86
.95
150
R73
146-
5-20
0312
30N
SDS
32nd
9621
0nd
nd9.
6nd
1.60
3.0
19,0
001.
72.
001,
300
nd.8
51.
2016
0R
7415
6-5-
2003
1255
PP1
130
216
015
0nd
nd13
3.50
19.0
04.
021
0,00
0.7
3.80
2,60
0nd
3.90
2.50
12R
7515
6-5-
2003
1257
PP1
140
2.1
160
160
ndnd
143.
7019
.00
3.0
210,
000
.67
3.90
2,60
0nd
3.90
2.50
17
R76
156-
5-20
0313
20PP
290
nd16
015
0nd
nd23
1.20
8.60
3.0
150,
000
nd4.
202,
300
nd2.
801.
3014
R77
156-
5-20
0313
25N
SDS
791.
314
034
0nd
nd18
nd14
.00
5.0
110,
000
3.8
2.90
2,40
0nd
3.30
1.50
230
R78
156-
5-20
0313
35N
SDS
160
3.3
170
350
ndnd
113.
7019
.00
5.0
190,
000
5.7
3.10
2,50
01.
26.
604.
1021
0
Tables 6–8 51