Field Sampling and Your Bottom Line · 2018-02-28 · Analysis and associated calcinations are...

11
Field Sampling and Your Bottom Line

Transcript of Field Sampling and Your Bottom Line · 2018-02-28 · Analysis and associated calcinations are...

Page 1: Field Sampling and Your Bottom Line · 2018-02-28 · Analysis and associated calcinations are based on GPA 2261. GPA 2286, GPA 2145. AGA and TP-17. PROPER SAMPLING PROCEDURE; FIELD

Field Sampling and Your Bottom Line

Page 2: Field Sampling and Your Bottom Line · 2018-02-28 · Analysis and associated calcinations are based on GPA 2261. GPA 2286, GPA 2145. AGA and TP-17. PROPER SAMPLING PROCEDURE; FIELD

Operating Cost Reductions

Increase in operations moving to self sampling Things to be aware of:

•Sample containers •Field H2S determination •Impact of sampling procedures

Page 3: Field Sampling and Your Bottom Line · 2018-02-28 · Analysis and associated calcinations are based on GPA 2261. GPA 2286, GPA 2145. AGA and TP-17. PROPER SAMPLING PROCEDURE; FIELD

The “Creative” Sample Container

Page 4: Field Sampling and Your Bottom Line · 2018-02-28 · Analysis and associated calcinations are based on GPA 2261. GPA 2286, GPA 2145. AGA and TP-17. PROPER SAMPLING PROCEDURE; FIELD

Field H2S Determination

• H2S will degrade in metal cylinders • Stain tubes and Iodine have expiry dates • Have seen wells turn sour from 0 to >1000

ppm in a matter of months

Page 5: Field Sampling and Your Bottom Line · 2018-02-28 · Analysis and associated calcinations are based on GPA 2261. GPA 2286, GPA 2145. AGA and TP-17. PROPER SAMPLING PROCEDURE; FIELD

Sampling Case Study

•Same sample point •Same day •Same field staff •Two different sampling techniques

•Two cylinders taken properly (P1, P2) •Two cylinders taken improperly by purging through the cylinder (I3, I4)

Page 6: Field Sampling and Your Bottom Line · 2018-02-28 · Analysis and associated calcinations are based on GPA 2261. GPA 2286, GPA 2145. AGA and TP-17. PROPER SAMPLING PROCEDURE; FIELD

Proper Sampling Results

Page 7: Field Sampling and Your Bottom Line · 2018-02-28 · Analysis and associated calcinations are based on GPA 2261. GPA 2286, GPA 2145. AGA and TP-17. PROPER SAMPLING PROCEDURE; FIELD

Improper Sampling Results

Page 8: Field Sampling and Your Bottom Line · 2018-02-28 · Analysis and associated calcinations are based on GPA 2261. GPA 2286, GPA 2145. AGA and TP-17. PROPER SAMPLING PROCEDURE; FIELD

Compositional Summary

0.0000

0.1000

0.2000

0.3000

0.4000

0.5000

0.6000

0.7000

H2 He N2 CO2 H2S C1 C2 C3 iC4 nC4 iC5 nC5 C6 C7+

Correct 1

Incorrect 1

Correct 2

Incorrect 2

Page 9: Field Sampling and Your Bottom Line · 2018-02-28 · Analysis and associated calcinations are based on GPA 2261. GPA 2286, GPA 2145. AGA and TP-17. PROPER SAMPLING PROCEDURE; FIELD

Gas Properties

P1 P2 I3 I4 Heating Value 52.40 52.55 55.62 53.75 Gas Compressibility 0.9925 0.9925 0.9900 0.9916 Relative Density 0.882 0.883 0.934 0.900

1% RD exemption is affected by sampling in this case study

Page 10: Field Sampling and Your Bottom Line · 2018-02-28 · Analysis and associated calcinations are based on GPA 2261. GPA 2286, GPA 2145. AGA and TP-17. PROPER SAMPLING PROCEDURE; FIELD

Historical Data

Page 11: Field Sampling and Your Bottom Line · 2018-02-28 · Analysis and associated calcinations are based on GPA 2261. GPA 2286, GPA 2145. AGA and TP-17. PROPER SAMPLING PROCEDURE; FIELD

Thank You