Fiber Polishing Fiber Testing - connectworld.neteia/tia 568a specifications. certified to 100 mhz....

24
F A X T H A T P I N O U T 1 5 7 3 2 4 3 1 3 6 5 Hand Soldering Copper Testing 281 LOTUS DRIVE • JACKSON, MO 63755 YOUR DATA, VOICE, LAN & WAN SOURCE FOR NOW AND THE FUTURE! Fiber Testing Fiber Polishing Major Custom Cable 1-800-455-6224 MCC # 03/01

Transcript of Fiber Polishing Fiber Testing - connectworld.neteia/tia 568a specifications. certified to 100 mhz....

  • FAX

    THAT

    PIN

    OUT

    1•573•243•1365

    Hand Soldering

    Copper Testing

    281 LOTUS DRIVE • JACKSON, MO 63755

    YOUR DATA,VOICE, LAN & WAN

    SOURCEFOR NOW

    AND THE FUTURE!

    Fiber Testing

    Fiber Polishing

    MajorCustomCable

    1-800-455-6224MCC # 03/01

  • 2

    YOUR CUSTOM CABLE SPECIALISTS!INDEX

    Jacket Color Code 3Custom Imprinting & Custom Lengths 3Media Twist & Lanmark 1000 3Data Twist 350 & Lanmark 350 4Category 5 Patch Cords 4Category 3, 5 & 5E Solid Jumper Cables 5110 Patch Cords 5Telco & Power Sum Assemblies 6T1 Assemblies 7DS-3/4 Coaxial Cables 7Ethernet Assemblies 8Twinaxial & Token Ring Assemblies 9EMC 300 MHz Data Assemblies 9Fiber Optics 10, 13Cisco Router Cable Assemblies 14, 16SCSI Cable Assemblies 17V.35 & Null Modem Assemblies 18DB & RS 232 Assemblies 19VGA Monitor & SVHS Assemblies 20Coaxial Cables RG59 21RGB Coaxial Cables 21Keyboard & Enhanced Parallel Printer Cables 22Hydra and Octopus Assemblies 23

    Service...We pride ourselves on understanding your business as

    well as our own. You will find our staff understands the value ofcorrect information and critical deadlines. Our systems are setup for automatic blind drop shipping to insure customerconfidentiality.

    Sales Staff...Our sales force is on site at our Jackson, Missouri facility. We handle the majority of our

    business by phone, with periodic personal visits. We feel this method is the most effective way foryour people and ours to partner on quotes and bids. The manufacturing information, schedulingand special shipping arrangements can be easily handled to win the various project business for bothof our companies.

    We Have No Order Takers...Our sales staff is trained and updated on the latest product and specification information in

    this ever changing industry. They are trained to be the liaison between your purchasing personneland our production staff; helping our customers choose the proper cable for the application.Our engineers are on site to help with requirements or specification issues.

    RETURNSIf one of our assemblies is found to be defective we will be glad to replace it at no charge. We must be notified within 30days of invoice and before returning any product, a Return Material Authorization (RMA) number must be issued on themerchandise. RMA numbers are valid for 20 days. Please return with the RMA number posted on the outside of eachshipping package. Orders for Custom manufactured products are non-cancelable and non-refundable. This includesproducts with custom lengths, configurations or customer supplied prints or specifications. If you or your customer havea mistake on a custom product, we will be glad to rework the assembly at a nominal charge.

    PRODUCT WARRANTYA Life-Time workmanship Warranty is provided on all products manufactured by MCC. Warranty is limited to repairing orreplacing products which prove to be defective upon inspection. Some products provided by (but not manufactured by)MCC are covered by the warranty of their respective manufacturers. Abuse, alteration, or misuse voids all warranties.

  • 31-800-455-6224 • FAX: 1-573-243-1365

    CHECK LIST:1. CONNECTORS (RJ45 or BLUNT)?2. WIRE CODE (568A, 568B, ...etc.)?3. LENGTH (STOCK 3, 5, 7, 14, 20 & 25 FEET)?4. COLOR?5. BOOTS?6. CUSTOM IMPRINTING?

    Category 6 Patch Cords (1000 Mbps)UTP Cables Supporting ...• Meets Proposed Category 6 Specifications• 10 Base T, Token Ring, 100 Base T, FDDI/TP - PMD,

    155/622 ATM and GigaBit Ethernet• Analog Audio, Analog Video, AES/EBU Digital

    Audio, Digital Video, Serial Digital Video to Mbps(135 Mhz) and Beyond

    • Analog Broadcast to Channel 45 (354 Mhz) and ashigh as Channel 70 (500 Mhz)

    Berk-TekLanmark 1000

    ASSEMBLY #

    PVC STRANDEDM64CBPA?????

    M64CBPA??B???

    STANDARDWIRE CODES

    (E) = RJ45 568A(P) = RJ45 568B (PDS, AT&T, 258A)

    (V) = 568A or 568B CROSSOVER

    NOTSHOWN

    BeldenMedia Twist

    ASSEMBLY #

    PVC STRANDED*M64CAPA?????M64CAPA??B???

    (E) 568ASpecial

    Order Only

    * PART # EXAMPLE (M64CAPA??B???)M (Modular) 6 (Category 6) 4 (Pair) C (Stranded) A (Belden) P (568B) A (Mod to Mod) ?? (Color) B (Boots) ??? (Footage)

    Custom Imprinting!

    Custom Lengths!WE WILL CUT YOUR CABLES TO ANY LENGTH

    WITHIN ENGINEERING SPECIFICATIONS FOR THETYPE OF CABLE THAT YOU REQUIRE.

    CUSTOM IMPRINTED CABLESWILL ALLOW YOU TO OFFER THE COMBINATION OF

    HIGH QUALITY AND YOUR PERSONALIZEDCOMPANY IDENTIFICATION.

    Patch Cord & JumperCable Colors

    Subject to AvailabilityJacket and Boot Color Code

    BE - BEIGE (DEC GRAY)BK - BLACKBL - BLUEGY - GRAY (CHROME)GN - GREENHP - HOT PINK

    OR - ORANGEPR - PURPLERD - REDWT - WHITEYL - YELLOW

    Cable ManufacturerA = Belden

    B = Berk-Tek

    PLEASECALL FOR

    STOCKCOLORS

    PLEASECALL FOR

    STOCKCOLORS

    100%TESTED! PLEASE

    CALL FORSOLID PVCor PLENUM

  • 4 1-800-455-6224 • FAX: 1-573-243-1365

    CHECK LIST:

    1. CONNECTORS (RJ45 or BLUNT)?2. CABLE (STRANDED PVC, SOLID PVC or PLENUM)?3. NUMBER OF PAIRS (2 or 4)?4. WIRE CODE (568A, 568B, etc...)?5. LENGTH (STOCK 3, 5, 7, 14, 20 & 25 FEET)?6. COLOR?7. BOOTS?8. CUSTOM IMPRINTING?

    Category 5e Patch Cords (350 Mhz)The 350 Mhz Enhanced Patch Cords ...

    • Provide 350 Mhz performance, exceeding theEIA/TIA 568A Category 5 requirements (100 Mhz)

    • Supports the 155 Mbps transmission raterequired for ATM (Asynchronous Transfer Mode).

    • Supports high speed network applications requiringspectral bandwidths that may extend to 350 Mhz.

    BeldenData Twist 350

    ASSEMBLY #

    PVC STRANDEDME4CA?A?????

    WITH BOOTSME4CA?A??B???

    NOTSHOWN

    Berk-TekLanmark 350

    ASSEMBLY #

    PVC STRANDEDME4CB?A?????WITH BOOTS

    ME4CB?A??B???

    Cable ManufacturerA = Belden

    B = Berk-Tek

    Category 5 Patch Cords (100 Mhz)

    100%TESTED!

    * PART # EXAMPLE (M54CBPA??B???)M (Modular) 5 (Category 5) 4 (Pair) C (Stranded) B (Berk-Tek) P (568B) A (Mod to Mod) ?? (Color) B (Boots) ??? (Footage)

    24 AWG.4 Pair Stranded

    PVC UTPASSEMBLY #

    With Boots*M54CBPA??B???

    Without BootsM54CBPA?????

    Cable ManufacturerB = Berk-Tek

    OUR CATEGORY 5PATCH CORD ASSEMBLIES ARE

    100% TESTED AND VERIFIED TO MEETEIA/TIA 568A SPECIFICATIONS.

    CERTIFIED TO 100 Mhz.

    STANDARDWIRE CODES

    (E) = RJ45 568A(P) = RJ45 568B (PDS, AT&T, 258A)

    (V) = 568A or 568B CROSSOVER

    24 AWG.4 Pair Solid

    UTPASSEMBLY #

    PVCM54AMPA??B???M54AMPA?????

    PLENUMM54BMPA??B???M54BMPA?????

    Cable ManufacturerM = Mohawk

    PLEASECALL FOR

    STOCKCOLORS

    PLEASECALL FOR

    STOCKCOLORS

    STANDARDWIRE CODES

    (E) = RJ45 568A(P) = RJ45 568B (PDS, AT&T, 258A)

    (V) = 568A or 568B CROSSOVER

    PLEASECALL FORSOLID PVCor PLENUM

    PLEASECALL FORSOLID PVCor PLENUM

  • 51-800-455-6224 • FAX: 1-573-243-1365

    CHECK LIST: 1. CATEGORY (3, 5 or 5e) 2. CONNECTORS (RJ11, MMP, RJ45 or BLUNT)? 3. CABLE (SOLID PVC or PLENUM)? 4. NUMBER OF PAIRS (2, 3 or 4)? 5. WIRE CODE (568A, 568B, USOC ...etc.)? 6. LENGTH? 7. BOOTS (RJ45 ONLY)? 8. CUSTOM IMPRINTING?

    Category 5e4 Pair (RJ45/RJ45)Solid • UTP

    ASSEMBLY #

    PVCME4A?EA?????ME4A?PA?????ME4A?VA?????

    PLENUMME4B?EA?????ME4B?PA?????ME4B?VA?????

    Category 3, 5, 5e Solid Jumper Cables

    100%TESTED!

    CHECK LIST:

    1. NUMBER of PAIRS on CABLE (1, 2, 3 or 4)?2. CONNECTORS (110 or RJ45)?3. NUMBER of PAIRS on 110 CONNECTOR (1, 2, 3 or 4)?4. WIRE CODE (110 to RJ45) (USOC, 568A, 568B, or 10 BASE T)?5. COLOR?6. LENGTH?

    Category 52 Pair (RJ11/RJ11)Solid • UTP

    ASSEMBLY #

    PVCM52A?AA?????M52A?BA?????

    PLENUMM52B?AA?????M52B?AB?????

    STANDARDWIRE CODES

    (A) = USOC FLIPPED(B) = USOC ST THRU

    100%TESTED!

    Category 5110 Patch Cords

    4 Pair

    ASSEMBLY #110/110

    AT54C-??-??110/RJ45

    ATM54C45B-??-??ATM54C45E-??-??ATM54C45P-??-??

    CATEGORY 3SOLID JUMPER CABLES

    NOT SHOWN

    PLEASECALL FOR

    QUOTES

    ASSEMBLY #

    PVCM53A?FA?????M53A?GA?????M53A?HA?????

    PLENUMM53B?FA?????M53B?GA?????M53B?HA?????

    ASSEMBLY #

    PVCM54A?EA?????M54A?PA?????M54A?VA?????

    PLENUMM54B?EA?????M54B?PA?????M54B?VA?????

    Category 53 Pair (DEC Assemblies)

    Solid • UTP

    Category 54 Pair (RJ45/RJ45)Solid • UTP

    STANDARD WIRE CODES(B) = USOC(E) = 568A(P) = 568B

    2 Pair

    ASSEMBLY #110/110

    AT52C-??-??110/RJ45

    ATM52C45B-??-??ATM52C45T-??-??

    STANDARD WIRE CODES(B) = USOC

    (T) = 10 BASE T

    STANDARD WIRE CODES(E) = RJ45 568A

    (P) = RJ45 568B (PDS, AT&T, 258A)(V) = 568A or 568B CROSSOVER

    STANDARD WIRE CODES(F) = DEC FLIPPED(G) = DEC ST THRU

    (H) = DEC CONVERSION (RJ11/MMP)

    PLEASECALL FOR

    STOCKCOLORS

    PLEASECALL FOR

    STOCKCOLORS

  • 6 1-800-455-6224 • FAX: 1-573-243-1365

    Telco 25 Pair Assemblies

    PART # EXAMPLE (T3AMS9SFS9S)T (TELCO) 3 (Category 3) A (PVC Solid)

    MS9 (First Connector [90° Male]) S {Standard Exit)FS9 (Second Connector [90° Female]) S {Standard Exit)

    Category 3(Male or Female) 24 AWG. UTP

    ASSEMBLY #

    PVCT3AMS9SMS9S-???T3AMS9SFS9S-???T3AFS9SFS9S-???

    T3AMS9SB-???T3AFS9SB-???

    Power Sum 300 MHz Telco AssembliesLUCENT (Part #'s)

    TPLALM1LM1 180 Degree HoodTPLALM2SLM2S 120 Degree HoodTPLALM9SLM9S 90 Degree Hood

    TPLALF9SLF9S 90 Degree Hood Female

    AMP (Part #'s)TPSAAM1AM1 180 Degree Hood

    TPSAAM2SAM2S 120 Degree HoodTPSAAM9SAM9S 90 Degree Hood

    This cable is only to be used withAMP Power Sum equipment.

    The wire configuration is not the same asstandard Category 1, 3, 4 or 5

    Telco Assemblies!AVAILABLE with PVC or PLENUM JACKET

    Standard RJ21XLucent offers Power Sum cables with full forward and backward compatibility

    for seamless Category 3, 4 and 5 connectivity with your equipment.AVAILABLE with PVC JACKET

    LUCENT PLENUM JACKET CUSTOM

    CHECK LIST:

    1. CATEGORY (1, 3, 5 or POWER SUM)?2. JACKET (PVC or PLENUM)?3. SINGLE or DOUBLE ENDED?4. GENDER (MALE or FEMALE)?5. HOOD DEGREE (90, 120 or 180 DEGREE)?6. 90 and 120 DEGREE HOOD (STANDARD or OPPOSITE EXIT)?7. LATCH TYPE (SCREW, or BAIL LOCK)?8. LENGTH?

    100%TESTED!

    AVAILABLE UPON REQUEST

    • SHIELDED TELCO ASSEMBLIES with 180° SHIELDED HOODS • INTEGRAL LATCHES (FEMALE ONLY)

    CUSTOMLENGTHS

    AVAILABLE

    CONNECTOR TYPEMS1 = MALE SCREW 180°MS2 = MALE SCREW 120°MS9 = MALE SCREW 90° (STANDARD)MB1 = MALE BAIL LOCK 180°MB2 = MALE BAIL LOCK 120°MB9 = MALE BAIL LOCK 90°FS1 = FEMALE SCREW 180°FS2 = FEMALE SCREW 120°FS9 = FEMALE SCREW 90° (STANDARD)FB1 = FEMALE BAIL LOCK 180°FB2 = FEMALE BAIL LOCK 120°FB9 = FEMALE BAIL LOCK 90°B = BLUNT

    Our assemblies exceed theEIA/TIA SP-2840 Power Sum

    crosstalk performance forCategory 5 applications.

    ASSEMBLY #

    PLENUMT3BMS9SMS9S-???T3BMS9SFS9S-???T3BFS9SFS9S-???

    T3BMS9SB-???T3BFS9SB-???

  • 71-800-455-6224 • FAX: 1-573-243-1365

    T1 Assemblies CHECK LIST: 1. CABLE (SOLID or STRANDED)? 2. JACKET (PVC or PLENUM)? 3. CONNECTORS (RJ45, DB15 or BLUNT)? 4. GENDER (MALE or FEMALE)? 5. LENGTH?

    DB15 to DB15(DB15 Male or Female)

    ASSEMBLY #

    STRANDED PVCT1C15M15M-???T1C15M15F-???T1C15F15F-???

    SOLID PLENUMT1B15M15M-???T1B15M15F-???T1B15F15F-???

    DB15 to RJ45(DB15 Male or Female)

    ASSEMBLY #

    STRANDED PVCT1C15M45-???

    RJ45 to RJ45

    ASSEMBLY #

    STRANDED PVCT1C4545-???

    SOLID PLENUMT1B4545-???

    DS-3/4 Coaxial Cables

    CHECK LIST: 1. JACKET (PVC or PLENUM)? 2. NUMBER OF COAX (1, 2, 3, 6, 8, 9, 12, etc...)? 3. WITH OR WITHOUT TRACER? 4. CONNECTORS (BNC, WECO, etc...)? 5. LENGTH (FEET or METERS)?

    Each DS-3 will carry up to 672 voice channels multiplexed to-gether and each DS-4 will carry up to 4032 voice channels.

    DS-3/4 cables are used in the telecommunications networks tointerconnect Transmission Equipment and Digital Cross Con-

    nect (DSX) systems together. DSX to Multiplexer, DSX toLightwave Systems or Digital Radio to Multiplexer.

    CUSTOMLENGTHS

    AVAILABLE

    DS3/4 735A1 COAX - SOLID COPPER

    BNC to BNC

    ASSEMBLY #

    DS73501ABB-???MULTICOAX

    AVALIABLE

    100%TESTED!

    PLEASECALL FORCUSTOMLENGTHS

    100%TESTED!

    STRANDEDASSEMBLIES

    ARE AVAILABLEIN PVC ONLY

    DS3/4 734A1 COAX - SOLID COPPER

    BNC to BNC

    ASSEMBLY #

    DS73401ABB-???SILVERPLATEDCOPPER

    AVAILABLE

  • 8 1-800-455-6224 • FAX: 1-573-243-1365

    Ethernet Assemblies

    MCC'sEthernet Assemblies

    are fullyIEEE 802.3 compliant.

    AUI ASSEMBLIES with90° HOODS

    Available upon Request

    100%TESTED!

    CHECK LIST:

    1. ASSEMBLY TYPE (TRUNK, THINNET, AUI or OFFICE AUI)?2. AUI HOODS (STRAIGHT or CUSTOM 90° RIGHT ANGLE)?3. CONNECTORS (MALE or FEMALE)?4. JACKET (PVC or PLENUM)?5. LENGTH?

    Trunk Cable(Backbone) - (Solid)

    ASSEMBLY #

    PVCETNA-???

    PLENUMETNB-???

    MAXIMUMLENGTH

    1,650 FEET(500 METERS)

    CUSTOMLENGTHS

    AVAILABLE

    Office Transceiver Cable(AUI Cable) - (Straight Hoods)(Male to Female) - (PVC only)

    ASSEMBLY #

    PVCEAUIOM1F1-???

    MAXIMUMLENGTH

    16.4 FEET(5 METERS)

    Transceiver Cable(AUI Drop Cable) - (Straight Hoods)

    ASSEMBLY #

    PVCEAUICM1F1-???

    PLENUMEAUIDM1F1-???

    MAXIMUMLENGTH164 FEET

    (50 METERS)

    MII Cable(100 Base T)

    ASSEMBLY #

    PVCEMIICMF-???

    MAXIMUMLENGTH

    19.6 INCHES(.5 METERS)

    NOTSHOWN

    Thinnet Cable(ThinWire) - (Stranded)

    ASSEMBLY #

    PVCETHC-???

    PLENUMETHD-???

    MAXIMUMLENGTH

    607 FEET(200 METERS)

    BOOTS Availableupon Request

  • 91-800-455-6224 • FAX: 1-573-243-1365

    Twinaxial Direct(Data to Twinaxial) - (Type 6)

    ASSEMBLY #

    TR6D4T-???

    Twinaxial to Twinaxial(100 ohm Twinaxial Cable)

    ASSEMBLY #

    PVCCTXATT-???

    PLENUMCTXBTT-???

    Twinaxial Assemblies

    CHECK LIST: 1. CONNECTORS (DATA, TWINAXIAL, ...etc.)? 2. JACKET (PVC or PLENUM)? 3. LENGTH?

    CHECK LIST:

    1. ASSEMBLY TYPE (PATCH, PC ADAPTER, ...etc.)? 2. CONNECTORS (DATA, DB9M or SHIELDED RJ45)? 3. GENDER (MALE or FEMALE)? 4. JACKET (PVC or PLENUM)? 5. LENGTH?

    Token Ring AssembliesToken Ring

    Adapter Cable(DB9 to Shielded RJ45)

    (Type 6)

    ASSEMBLY #

    10 BASE TTR69FMTR69MM

    TOKEN RINGTR69FMTTR69MMT

    EMC 300 MHz Data Assemblies

    100%TESTED!

    PLEASECALL FORCUSTOMLENGTHS

    100%TESTED!

    The EMC (Electro-Magnetic Control) Data Connector, from AMP,is STP-A performance tested perEIA/TIA 568A specifications. It is bandwidth specified through 300 MHz and is easily identified by itscompact design (1/2 inch shorter) and color (Pearl White). The EMC connector interface itself has notbeen changed making it compatible with ALL other data connectors!

    Patch Cable(Data to Data) - (Type 6)

    ASSEMBLY #

    TR6D4D4-???

    TYPE 9 AND OTHERIBM EQUIVALENT

    TOKEN RING ASSEMBLIES

    PLEASECALL FOR

    QUOTES

    PCAdapter Cable

    (DB9 to Data) - (Type 6)

    ASSEMBLY #

    TR69MD4-???TR69FD4-???

    100%TESTED!

    AVAILABLE IN ANY COMBINATION OF CONNECTORS SHOWN

  • 10 1-800-455-6224 • FAX: 1-573-243-1365

    Fiber Optic MultimodeMCC'S MULTIMODE FIBER ASSEMBLIES

    ARE LOSS GUARANTEED TO(-.5 dB) OR LESS PER MATED PAIR.

    100%TESTED!

    CHECK LIST:

    1. SIMPLEX or DUPLEX2. MODE (MULTIMODE 62.5/125, 50/125 or 100/140)?3. CONNECTOR TYPE (SC, FDDI, ST ...etc.)?4. CONNECTORS (Composite Polymer or Ceramic)?5. JACKET (PVC or PLENUM)?6. LENGTH (ALL LENGTHS IN FEET or METERS)?

    FC, MINI BNC, SCSMA 905, SMA 906, &

    STAINLESS STEEL ST CONNECTORS

    50/125, 100/140MULTIMODE ASSEMBLIES

    Please call forany Fiber

    Assembliesnot shown.

    AVAILABLE

    UPONREQUEST

    ST to ST Simplex

    ASSEMBLY #

    PVCFCS6ASTC-???

    PLENUMFCS6BSTC-???

    ST to ST DuplexASSEMBLY #

    PVCFCD6ASTC-???

    PLENUMFCD6BSTC-???

    SC to SC Simplex SC to SC Duplex

    ASSEMBLY #

    PVCFCS6ASCC-???

    PLENUMFCS6BSCC-???

    ASSEMBLY #

    PVCFCD6ASCC-???

    PLENUMFCD6BSCC-???

    Corning Cable Systems (Siecor)662.5/125

    Multimode Assemblies

    STII+ to STII+Simplex

    ASSEMBLY #

    PVCFLS6AST-???

    PLENUMFLS6BST-???

    ASSEMBLY #

    PVCFLD6AST-???

    PLENUMFLD6BST-???

    STII+ to STII+Duplex

    SC to SCSimplex

    SC to SCDuplexASSEMBLY #

    PVCFLD6ASC-???

    PLENUMFLD6BSC-???

    ASSEMBLY #

    PVCFLS6ASC-???

    PLENUMFLS6BSC-???

    LUCENT662.5/125

    Multimode Assemblies

  • 111-800-455-6224 • FAX: 1-573-243-1365

    LUCENTSingle-Mode Assemblies

    Corning Cable Systems (Siecor)Single-Mode Assemblies

    CHECK LIST:

    1. SIMPLEX or DUPLEX 2. CONNECTORS (SC, FDDI, ST ...etc.)? 3. SINGLE MODE POLISH (STANDARD, APC, UPC or SPC)? 4. JACKET (PVC or PLENUM)? 5. LENGTH (ALL LENGTHS IN FEET or METERS)?

    Fiber Optic Single-ModeMCC'S SINGLE-MODE FIBER ASSEMBLIES

    ARE LOSS GUARANTEED TO(-.5 dB) OR LESS PER MATED PAIR.

    SINGLE-MODE SPECIAL POLISHES

    • APC (ANGLE PHYSICAL CONTACT) (-65 dB LOSS)(SC and FC CONNECTORS ONLY)

    • SPC (SUPER PHYSICAL CONTACT) (-40 dB LOSS)• UPC (ULTRA PHYSICAL CONTACT) (-55 dB LOSS)

    AVAILABLE

    UPONREQUEST

    100%TESTED!

    STII+ to STII+SimplexASSEMBLY #

    PVCFLSSAST-???

    PLENUMFLSSBST-???

    STII+ to STII+DuplexASSEMBLY #

    PVCFLDSAST-???

    PLENUMFLDSBST-???

    SC to SCSimplexASSEMBLY #

    PVCFLSSASC-???

    PLENUMFLSSBSC-???

    SC to SCDuplexASSEMBLY #

    PVCFLDSASC-???

    PLENUMFLDSBSC-???

    SC to SC Simplex

    ASSEMBLY #

    PVCFCSSASC-???

    PLENUMFCSSBSC-???

    SC to SC Duplex

    ASSEMBLY #

    PVCFCDSASC-???

    PLENUMFCDSBSC-???

    ST to ST Simplex

    ASSEMBLY #

    PVCFCSSAST-???

    PLENUMFCSSBST-???

    ST to ST Duplex

    ASSEMBLY #

    PVCFCDSAST-???

    PLENUMFCDSBST-???

  • 12 1-800-455-6224 • FAX: 1-573-243-1365

    Multi Fiber Assemblies

    NON-BREAKOUT

    62.5/125 Breakout AssembliesBREAKOUT

    CHECK LIST:

    1. NON-BREAKOUT or BREAKOUT2. NUMBER OF FIBERS (2 thru 144)3. MODE (SINGLE-MODE or [MULTIMODE 62.5/125, 50/125 or 100/140])?4. CONNECTORS (SC, ST ...etc.)?5. JACKET (PVC or PLENUM)?6. LENGTH (FEET or METERS)?7. FURCATION TUBING (NON-BREAKOUT ONLY)?8. PULLING EYE FOR EASE OF INSTALLATION?

    100%TESTED!

    SC, SMA, POLYMER ST,FC, ESCON, &

    STAINLESS STEEL ST CONNECTORS

    SINGLE-MODE ASSEMBLIES &50/125, 100/140

    MULTIMODE ASSEMBLIES

    AVAILABLEUPONREQUEST

    62.5/125 Non-Breakout Assemblies

    CALLFOR

    CUSTOMQUOTES

    ASSEMBLY #

    FB604BST-?-???FB606BST-?-???FB608BST-?-???FB610BST-?-???FB612BST-?-???

    # OFFIBERS

    4681012

    ST to ST (Plenum)

    ST to ST (PVC)

    ASSEMBLY #

    FB602AST-?-???FB604AST-?-???FB606AST-?-???FB608AST-?-???FB610AST-?-???FB612AST-?-???FB618AST-?-???FB624AST-?-???FB636AST-?-???

    # OFFIBERS

    24681012182436

    ST to ST (PVC)ASSEMBLY #

    FN602AST-?-???FN604AST-?-???FN606AST-?-???FN608AST-?-???FN612AST-?-???

    # OFFIBERS

    246812

    ST to ST (Plenum)

    ASSEMBLY #

    FN604BST-?-???FN606BST-?-???FN608BST-?-???FN612BST-?-???

    # OFFIBERS

    46812

  • 131-800-455-6224 • FAX: 1-573-243-1365

    MTRJFiber Patch Cords

    • The MTRJ performs equally well for multimode and single-mode appli-cations. Performance is compliant with ISO/IEC 11801 and EIA/TIA 568A.The MT ferrule is a field proven technology with over a seven year track

    record and millions of installed parts.

    • The LC Solution is Bellcore, ANSI/EIA/TIA and IEC compliantand SYSTIMAX-SCS approved. For 900 Micron and 1.6 MM fi-

    ber both Simplex and Duplex.LC Duplex Multimode PVC

    using 1.6 MM Fiber

    • The OPTI-JACK is fully compliant with the fiber optic performancerequirements as specified in EIA/TIA 568A.

    OPTI-JACK/PLUGFiber Patch Cords

    High Density Fiber Optic Patch Cords 100%TESTED!

    PVC ASSEMBLY #

    FD6AMTN-???FD6AMTNSC-???FD6AMTNST-???

    PVC ASSEMBLY #

    FLD6ALCD-???FLD6ALCDSC-???FLD6ALCDST-???

    MTRJ CHECK LIST:

    1. MODE (MULTIMODE 62.5/125, 50/125, SINGLE MODE)?2. SECOND CONNECTOR TYPE (SC, ST, ...etc.)?3. SECOND CONNECTORS (Composite Polymer or Ceramic)?4. JACKET (PVC or PLENUM)?5. LENGTH (ALL LENGTHS IN FEET or METERS)?

    LC CHECK LIST:

    1. MODE (MULTIMODE 62.5/125, SINGLE MODE)?2. SECOND CONNECTOR TYPE (SC, ST, ...etc.)?3. JACKET (PVC or PLENUM)?4. LENGTH (ALL LENGTHS IN FEET or METERS)?

    PVC ASSEMBLY #

    FD6AOJ-???FD6AOJSC-???FD6AOJST-???

    OPTI-JACK CHECK LIST:

    1. MODE (MULTIMODE 62.5/125, 50/125, SINGLE MODE)?2. OPTI-JACK or PLUG?3. SECOND CONNECTOR TYPE (SC, ST, ...etc.)?4. SECOND CONNECTORS (Composite Polymer or Ceramic)?5. JACKET (PVC or PLENUM)?6. LENGTH (ALL LENGTHS IN FEET or METERS)?

    StandardPatch Cord Fiber

    MTRJ usingRibbon Fiber

    LCFiber Patch Cords

  • 14 1-800-455-6224 • FAX: 1-573-243-1365

    Cisco Router Cable Assemblies

    This is only a partial listing.Please call for

    price and availability ofunlisted cables.

    RS-232(HD60 Male to DB25 Male or Female)

    DCE ASSEMBLIES

    PVCCAB-232MC-???CAB-232FC-???

    PLENUMCAB-232MCP-???CAB-232FCP-???

    DTE ASSEMBLIES

    PVCCAB-232MT-???CAB-232FT-???

    PLENUMCAB-232MTP-???CAB-232FTP-???

    RS-530(HD60 Male to DB25 Male or Female)

    DTE ASSEMBLIES ONLY

    PVCCAB-530MT-???CAB-530FT-???

    PLENUMCAB-530MTP-???CAB-530FTP-???

    CHECK LIST:

    1. CISCO PART NUMBER?2. ROUTER MODEL (AGS, 2500, ...etc.)?3. ROUTER TYPE (DCE or DTE)?4. STANDARD SUPPORTED (V.35, RS232, ...etc.)?5. JACKET (PVC or PLENUM)?6. CONNECTOR TYPE (DB25, V.35, ...etc.)?7. CONNECTOR GENDER (MALE or FEMALE)?8. LENGTH?

    V.35(HD60 Male to V.35 Male or Female)

    DCE ASSEMBLIES

    PVCCAB-V35MC-???CAB-V35FC-???

    PLENUMCAB-V35MCP-???CAB-V35FCP-???

    DTE ASSEMBLIES

    PVCCAB-V35MT-???CAB-V35FT-???

    PLENUMCAB-V35MTP-???CAB-V35FTP-???

    X.21(HD60 Male to DB15 Male or Female)

    DCE ASSEMBLIES

    PVCCAB-X21MC-???CAB-X21FC-???

    PLENUMCAB-X21MCP-???CAB-X21FCP-???

    DTE ASSEMBLIES

    PVCCAB-X21MT-???CAB-X21FT-???

    PLENUMCAB-X21MTP-???CAB-X21FTP-???

    RS-449(HD60 Male to DB37 Male or Female)

    DCE ASSEMBLIES

    PVCCAB-449MC-???CAB-449FC-???

    PLENUMCAB-449MCP-???CAB-449FCP-???

    DTE ASSEMBLIES

    PVCCAB-449MT-???CAB-449FT-???

    PLENUMCAB-449MTP-???CAB-449FTP-???

    100%TESTED!

    For Cisco Router Models 7000, 2500 & 4000-NP-4T

    BE SURE OFROUTER TYPE

    DCE or DTE

  • 151-800-455-6224 • FAX: 1-573-243-1365

    CHECK LIST: 1. FOR AYSNC w/ ADAPTERS (DCE, DTE or MODEM)? 2. CONNECTOR GENDER (DB25 only MALE or FEMALE)? 3. LENGTH?

    Cisco Router Cable Assemblies continuedFor

    Cisco Router ModelsAGS+ & ASM-CS

    V.35(HD26 Male to V.35 Male or Female)

    DTE ASSEMBLIES

    PVCCAB-VTM-???CAB-VTF-???

    PLENUMCAB-VTMP-???CAB-VTFP-???

    Cisco Octal Cable Assemblies

    ASYNC(HD68 Male to 8 RJ45s)

    CAB-OCTAL-ASYNC

    ASYNC w/DB25 Adapters(HD68 Male to 8 DB25 Adapters Male or Female)

    DCECAB-OCTAL-FDCE or MDCE

    DTECAB-OCTAL-FDTE or MDTE

    MODEMCAB-OCTAL-FMOD or MMOD

    MODEM(HD68 Male to 8 DB25 Males)

    CAB-OCTAL-MODEM

    For Cisco Router Models 2509 thru 2512 • PVC Jacket

    100%TESTED!

    HSSI(High Speed Serial Interface)

    (MODEL 7000 ONLY)

    HSSI(MD50 Male to MD50 Male)

    DTE ASSEMBLIES ONLY

    PVCCAB-HSI1-???CAB-HNUL-???

    Maximum Length20 Feet (6 Meters)

    ForCisco Router Model

    7000 Only

  • 16 1-800-455-6224 • FAX: 1-573-243-1365

    Cisco Router Cable Assemblies continued

    For Cisco Router 7000 Series

    STANDARD LENGTH10 Feet

    Maximum Length20 Feet (6 Meters)

    We make Cisco Router Cable Assemblies for each Series Listed below.Universal Access Server

    7000 • 4000 • 3800 • 3600 • 2600 • 2500 • 1600 • 1500 • CS500Smart Serial Cables for Cisco 2600 Series.

    For Cisco Catalyst Switches Telco to RJ45

    TPL25ACATALYST(Catalyst 5000)Telco to RJ45

    Cable assemblies that far exceed theCategory 5 Power-Sum

    requirements.This assembly is designed to be

    used with 10 Base-T and 100 Base-TRJ45 Ethernet Switching ModulesWS-x5010. WS-x5013.WS-x5224,WS-x5213A,WS-x5223,WS-x5203

    and standard 10/100 Base-T patch panel.

    CAB-OCT-232MT(LFH 200M to DB25M)

    232 DTE

    CAB-OCT-V35MT(LFH 200M to V.35M)

    V.35 DTE

    CAB-OCT-X21MT(LFH 200M to DB15M)

    X.21 DTE

    100%TESTED!

  • 171-800-455-6224 • FAX: 1-573-243-1365

    SCSI 1(Centronics 50 Male to

    DB50 Male)ASSEMBLY #

    SZCC50D50-N-BKSZCC50D50-N-GY

    CHECK LIST:

    1. CONNECTOR TYPE (CENTRONICS, MICRO D 50, ...etc.)? 2. GENDER (MALE or FEMALE)? 3. LATCH TYPE (THUMB SCREW or SPRING LATCH)? 4. JACKET COLOR (BLACK or GRAY) 5. LENGTH?

    SCSI Cable Assemblies

    100%TESTED!

    28 AWG. STRANDED TWISTED PAIRPVC LOW CAPACITANCE

    DOUBLE SHIELDED FOIL W/BRAIDSHIELDED HOODS

    INTERNAL SCSI CABLESALSO AVAILABLE

    SCSI 2(DB50 Male to

    Micro D50 Male)

    ASSEMBLY #

    SZCD50M5L-N-BKSZCD50M5L-N-GY

    SCSI 2(Micro D50 Male toMicro D50 Male)

    ASSEMBLY #

    SZCM5LM5L-N-BKSZCM5LM5L-N-GY

    SCSI 1 to SCSI 3(Centronics 50 Male to

    Micro D68 Male)

    ASSEMBLY #

    SZCC50M6S-?-BKSZCC50M6S-?-GY

    Micro D68 AlsoAvailable

    with Latches

    SCSI 1 to SCSI 2(Centronics 50 Male to

    Micro D50 Male)

    ASSEMBLY #

    SZCC50M5L-N-BKSZCC50M5L-N-GY

    SCSI 3(Micro D68 Male toMicro D68 Male)

    ASSEMBLY #

    SZCM6SM6S-N-GYSZCM6SM6S-N-BK

    Micro D68swith

    Thumb Screws

    PLEASECALL FOR

    QUOTES

    Must know ifDIFFERENTIAL

    orSINGLE ENDED

    If you cannot find thecable you require, please

    call us.

    SCSI 1(Centronics 50 Male toCentronics 50 Male)

    ASSEMBLY #

    SZCC50C50-N-BKSZCC50C50-N-GY

  • 18 1-800-455-6224 • FAX: 1-573-243-1365

    V.35 to V.35 Assemblies

    Null Modem Assemblies

    CHECK LIST:

    1. NO HANDSHAKE or FULL HANDSHAKE2. CONNECTOR (DB9 or DB25)?2. GENDER (MALE or FEMALE)?4. HOODS (HIGH IMPACT PLASTIC, METALIZED PLASTIC or METAL)?5. JACKET (PVC or PLENUM)?6. LENGTH?

    CHECK LIST:

    1. CONDUCTORS (19 or 34)?2. GENDER (MALE or FEMALE)?3. JACKET (PVC or PLENUM)?4. LENGTH?

    100%TESTED!

    PLEASECALL FOR

    QUOTES

    DB25 to DB25(Full Handshake) (4 Pair)

    ASSEMBLY #

    PVCNMCFH25F25F-???NMCFH25F25M-???NMCFH25M25M-???

    PLENUMNMDFH25F25F-???NMDFH25F25M-???NMDFH25M25M-???

    34 ConductorFoil Shielded

    (18 1/2 Pair Low Cap)

    ASSEMBLY #

    PVCV3534CMM-???V3534CMF-???V3534CFF-???

    PLENUMV3534DMM-???V3534DMF-???V3534DFF-???

    19 ConductorFoil Shielded

    (9 Pair Low Cap)

    ASSEMBLY #

    PVCV3519CMM-???V3519CMF-???V3519CFF-???

    PLENUMV3519DMM-???V3519DMF-???V3519DFF-???

    DB25 to DB25(No Handshake) (2 Pair)

    ASSEMBLY #

    PVCNMCNH25F25F-???NMCNH25F25M-???NMCNH25M25M-???

    PLENUMNMDNH25F25F-???NMDNH25F25M-???NMDNH25M25M-???

    100%TESTED!

  • 191-800-455-6224 • FAX: 1-573-243-1365

    "D" Subminiature Assemblies CHECK LIST:

    1. PIN OUT REQUIRED (ON ASSEMBLIES NOT LISTED) 2. CONNECTORS (DB9, DB15, DB25, DB37 or DB50)? 3. HOODS (HIGH IMPACT PLASTIC, METALIZED PLASTIC or METAL)? 4. GENDER (MALE or FEMALE)? 5. JACKET (PVC or PLENUM)? 6. LENGTH?

    LOW CAP24 AWG.

    PVC or PLENUMFOIL SHIELD

    FAX THOSE PIN OUTSFOR CUSTOM QUOTES!

    RS 232 Assemblies

    DB9, DB15, DB25, DB37 and DB50 AssembliesFully Loaded Straight Through

    DB15 ASSEMBLY #

    PVCDB15CMM-???DB15CMF-???DB15CFF-???

    PLENUMDB15DMM-???DB15DMF-???DB15DFF-???

    DB25 ASSEMBLY #

    PVCDB25CMM-???DB25CMF-???DB25CFF-???

    PLENUMDB25DMM-???DB25DMF-???DB25DFF-???

    DB37 ASSEMBLY #

    PVCDB37CMM-???DB37CMF-???DB37CFF-???

    PLENUMDB37DMM-???DB37DMF-???DB37DFF-???

    DB50 ASSEMBLY #

    PVCDB50CMM-???DB50CMF-???DB50CFF-???

    PLENUMDB50DMM-???DB50DMF-???DB50DFF-???

    DB25 (4 Conductor)(Wired 1, 2, 3, 7, 20 Shield to 1)

    ASSEMBLY #

    PVCRS4CMM-???RS4CMF-???RS4CFF-???

    PLENUMRS4DMM-???RS4DMF-???RS4DFF-???

    ASSEMBLY #

    PVCRS8CMM-???RS8CMF-???RS8CFF-???

    PLENUMRS8DMM-???RS8DMF-???RS8DFF-???

    DB25 (8 Conductor)(Wired 1 - 8, 20 Shield to 1)

    DB25 (12 Conductor)(Wired 1 - 8, 15, 17, 20, 22 Shield to 1)

    ASSEMBLY #

    PVCRS12CMM-???RS12CMF-???RS12CFF-???

    PLENUMRS12DMM-???RS12DMF-???RS12DFF-???

    DB25Fully Loaded Straight Through

    ASSEMBLY #

    PVCDB25CMM-???DB25CMF-???DB25CFF-???

    PLENUMDB25DMM-???DB25DMF-???DB25DFF-???

    CHECK LIST:

    1. NUMBER of CONDUCTORS (4, 8, 12, or 25)? 2. GENDER (MALE or FEMALE.)? 3. HOODS (HIGH IMPACT PLASTIC, METALIZED PLASTIC or METAL)? 4. JACKET (PVC or PLENUM)? 5. LENGTH?

    100%TESTED!

    DB9 ASSEMBLY #

    PVCDB9CMM-???DB9CMF-???DB9CFF-???

    PLENUMDB9DMM-???DB9DMF-???DB9DFF-???

    100%TESTED!

  • 20 1-800-455-6224 • FAX: 1-573-243-1365

    CHECK LIST:

    1. MONITOR TYPE (IBM, MACINTOSH, ...etc.)?2. JACKET (PVC or PLENUM)?3. CONNECTOR TYPE (HD15 or DB15)?4. GENDER (MALE or FEMALE)?5. LENGTH? 100%

    TESTED!

    VGA Monitor Cables

    MAXIMUMLENGTH

    (50 FEET)

    HD15 to HD15(Standard)

    ASSEMBLY #

    PVCVGACH15MM-???VGACH15MF-???

    PLENUMVGADH15MM-???VGADH15MF-???

    ASSEMBLY #

    PVCVGACD15MM-???VGACD15MF-???

    PLENUMVGADD15MM-???VGADD15MF-???

    DB15 to DB15(Macintosh)

    SVHS Assemblies

    ASSEMBLY #

    ZIPSVZ4MDM4MDM-???SVZ4MDM4MDF-???SVZ4MDF4MDF-???

    SVHS(Mini Din 4 to Mini Din 4)

    MAXIMUMLENGTH

    (100 FEET)

    CHECK LIST:

    1. CABLE TYPE (ZIP Only)?2. CONNECTOR ( MINI DIN 4 or BNC)?3. GENDER (MALE or FEMALE)(NO FEMALE BNC's)?4. LENGTH?

    100%TESTED!

  • 211-800-455-6224 • FAX: 1-573-243-1365

    RG59 Coaxial CablesRG59 75 OHM COAXIAL CABLE23 AWG. 95% BARE COPPER

    &AVAILABLE IN ANY COMBINATION

    OF CONNECTORS SHOWN

    RGB Coaxial Cables

    CHECK LIST:

    1. CONNECTOR TYPE (BNC, F CONNECTOR, RCA or UHF)? 2. JACKET (PVC or PLENUM)? 3. BOOTS (BNC ONLY)? 4. LENGTH?

    CHECK LIST:

    1. NUMBER OF COAX CABLES (3, 4 or 5)? 2. CONNECTOR TYPE (BNC, HD15, ...etc.)? 3. GENDER (MALE or FEMALE)? 4. LENGTH?

    PLEASESPECIFYLENGTH

    100%TESTED!

    100%TESTED!

    BNC to BNC

    ASSEMBLY #

    C59ABB-???

    WITH BOOTSC59ABBB-???

    RCA to RCA

    ASSEMBLY #

    C59ARR-???

    UHF to UHFASSEMBLY #

    C59AUU-???

    ASSEMBLY #

    RGB3CBB-???RGB4CBB-???RGB5CBB-???

    BNC to BNC(3 to 3, 4 to 4 or 5 to 5)

    5 BNC to DB9 Male

    ASSEMBLY #

    RGB5CBD9M-???

    5 BNC to HD15 MaleASSEMBLY #

    RGB5CBH15M-???

    4 BNC to DB15 Male(MAC II 13" Monitor)

    ASSEMBLY #

    RGB4CBD15M-???Other MacintoshCables Available

    F Connector toF Connector

    ASSEMBLY #

    C59AFF-???

  • 22 1-800-455-6224 • FAX: 1-573-243-1365

    Keyboard CablesPS/2

    (Mini Din 6 to Mini Din 6)

    ASSEMBLY #

    PVCDNCM6MM6M-??DNCM6MM6F-??

    PLENUMDNDM6MM6M-??DNDM6MM6F-??

    PS/2 • PC Adapter(Din 5 Male to Mini Din 6 Female)(Din 5 Female to Mini Din 6 Male)

    ASSEMBLY #

    PVCDNC5MM6F-??DNC5FM6M-??

    PLENUMDND5MM6F-??DND5FM6M-??

    PC/AT(Din 5 to Din 5)

    ASSEMBLY #

    PVCDNC5M5M-??DNC5M5F-??

    PLENUMDND5M5M-??DND5M5F-??

    Enhanced Parallel Printer Cables (IEEE 1284)Up to 10 times faster than stan-dard parallel printer cables.Use these cables with all IEEE1284 Bi-directional compliantdevices.

    CHECK LIST:

    1. COMPUTER TYPE (PC/AT, PS/2 or MACINTOSH)?2. KEYBOARD TYPE (PC/AT or PS/2)?3. CONNECTOR TYPE (DIN 5, MINI DIN 8 ...etc.)?4. GENDER (MALE or FEMALE)?5. LENGTH?

    CHECK LIST:

    1. CONNECTOR TYPE (DB25, CENTRONICS 36 etc...)?2. GENDER (MALE or FEMALE)?3. LENGTH (MAXIMUM LENGTH 33 FEET)?

    100%TESTED!

    IEEE 1284DB25 to Centronics 36

    ASSEMBLY #

    PVCEPCD25MCN36MEPCD25MCN36FEPCD25FCN36MEPCD25FCN36F

    IEEE 1284Centronics 36/Centronics 36

    or Micro Centronics 36ASSEMBLY #

    PVCEPCCN36MCN36MEPCCN36MCN36FEPCCN36FMC36MEPCCN36MMC36M

    MAXIMUMLENGTH

    (50 FEET)

    PLEASESPECIFYLENGTH

    100%TESTED!

  • 231-800-455-6224 • FAX: 1-573-243-1365

    CHECK LIST:

    1. CATEGORY (3 or 5)? 2. NUMBER OF CONDUCTORS (2, 4, 6 or 8)? 3. CABLE (SOLID or STRANDED) 4. WIRE CODE (USOC, 568A, 568B...etc.)? 5. CONNECTOR TYPE (RJ45, RJ11 or BLUNT)? 6. TELCO HOOD DEGREE (90°,120° or 180°)? 7. 90° and 120° HOOD (STANDARD or OPPOSITE EXIT)? 8. TELCO GENDER (MALE or FEMALE)? 9. JACKET (PVC or PLENUM)? 10. NUMBER OF LEGS? 11. LENGTH? 12. SPECIAL INSTRUCTIONS (LABELING, ...etc.)?

    Octopus Assemblies

    Hydra Assemblies

    100%TESTED!

    CHECK LIST:

    1. PIN OUT REQUIRED 2. CONNECTOR TYPE (DB25, DB15, DB9, DATA, etc...)? 3. CABLE (STRANDED only) 4. GENDER (MALE or FEMALE)? 5. TELCO HOOD DEGREE (90°,120° or 180°)? 6. JACKET (PVC or PLENUM)? 7. NUMBER OF LEGS? 8. LENGTH? 9. SPECIAL INSTRUCTIONS (LABELING, ...etc.)?

    Hydra AssembliesTelco to RJ11, RJ45 or MMP

    100%TESTED!

    PIN OUTREQUIRED FOR

    THESEASSEMBLIES

    Hydra and Octopus cables are available inmany variations. As they are CustomCable Assemblies, these cables aremanufactured to meet your specific

    requirements.Please call for quotes.

  • 24 1-800-455-6224 • FAX: 1-573-243-1365

    3MAIM/CAMBRIDGE

    ALPHA PRODUCTSTYCO/AMPAMPHENOL

    AUGAT/THOMAS & BETTSBELDEN

    BERK-TEKC & M CORP.

    COMMSCOPECOMTRAN

    CORNING CABLE SYSTEMS/SIECORCOVIDFESTO

    GEI ELECTRONICSGENERAL CABLE

    HELIXHEWLETT PACKARD

    LUCENT TECHNOLOGIESMADISON

    MANHATTANMETHODEMOHAWKMOLEXMOYCO

    NORTHERN TECHNORDX CDT

    OCCPREH

    PRESTOLITESENTINELSTEWARTTELEDYNE

    TROMPETERQUABBIN

    OURFRIENDSIN THE