FIBER OPTICPATCHCORD
&PIGTAIL
turksat.com.tr |
MM Multi Mode• 50/125 OM2• 50/125 OM3• 50/125 OM3+/OM4• Giga optimized for 1310nm transmission
1000Base-LX do 2000 m• 62.5/125 OM1
SM Single Mode• G652D Fiber with low water peak• G655 NZDS fiber for CWDW and DWDM
transmissions• G656 NZDS fiber for CWDW and DWDM
transmissions• G657A Fiber with low bending radius for
FTTH Networks,compatible with G652 • G657B Fiber with low bending radius for FTTH
Networks
PATCHCORDS
Automatic process of components preparation as well as connectors polishing have influence on final product parameters.Restrictive quality and measurement verification process based on:• Visual connectors’ inspection through a Westover microscope,automatic scratches and surface
detection program• Attenuation measurement of insertion Loss IL and Return Loss RL EXFO• Geometrical connectors measurement Interferometer SHUTTLE X
A fiber-optic patchcord connects two distance fiber optic ends and uses the same type of fiber and connections as the tips of the respective fibers it connects.In the context of optogenetics experiments with the rotary joint, a fiber optic patchcord is needed to connect the light source and the rotary joint and yet another patch cord to connect the rotary joint and the fiber optic cannula.
FIBER OPTIC PATCHCORDS
PATCHCORDS
turksat.com.tr |
PATCHCORDS
STANDART TYPE PATCHCORDS
Attenuation Of random taken connections dBAcc. IEC 61300-3-34
Attenuation Towards reference connector dBAcc. IEC 61300-3-4 Acc. IEC61300-3-6
Connectors SM: ST, SC, FC, LC, E2000, MU, DIN
Connectors SM: MTRJ
Connectors SM MT: MTP, MPO
Connectors SM APC: SC/APC, FC/APC, LC/APC, E2000/APC, MU/APC, DIN/APC
Connectors MM: ST, SC, FC, LC, E2000, MU
Connectors MM: MTRJ
Connectors MM MT: MTP, MTPO
IL conn.-conn.97%≤0,6 dBAverage ≤ 0,20 dB
IL conn.-conn.95%≤0,6 dBAverage ≤ 0,30 dB
IL conn.-conn.97%≤0,70 dBAverage ≤ 0,35 dB
IL conn.-conn.97%≤0,45 dBAverage ≤ 0,20 dB
IL conn.-conn.97%≤0,70 dBAverage ≤ 0,35 dB
IL conn.-conn.97%≤0,75 dBAverage ≤ 0,50 dB
IL conn.-conn.97%≤ 1 dBAverage ≤ 0,50 dB
IL max.≤0,30 dB
IL max.≤0,75 dB
IL max.≤0,30 dB
RL PC > 45RL UPC >50
RL PC > 35
RL PC > 55
RL APC > 65
RL PC > 30
RL PC > 26
RL PC > 26
TECHNICAL DATA, PARAMETERS
Connectors andAdapters, Assemblies, Termination Kitsand Tooling.
» Terminations: FC, SC, ST, MU, LC, D4, DIN, E2000, MT-RJ, MPO, SMA, E2000, FDDI, and ESCON
» Fiber diameter (mm): Φ 0.9, φ 2.0, Φ 3.0 and customized size » Fiber type: Single mode (G. 652, G655), multimode (50/125) /
(62.5/125), OM3, OM4 » Types: single mode, multimode » Insertion Loss (dB): less than 0.30 (PC and UPC) » Return Loss (dB): more than 0.45 (PC and UPC) » Exchangeability: less than 0.20 dB » Tensile Strength: less than 0.3 dB (0 to15 kgf ) » Temp. Range: (- 20 to +60 degree centigrade) » Types: PC, UPC, APC » Radius of Curvature: 10 to 25 mm, 5 to 15 mm » Apex O�set: ≤50 um; ≤100 um » Fiber Spherical Height: -90 nm, +50 nm » Angular O�set: 8°± 0.5°C (APC)
APPLICATIONS
turksat.com.tr |
PATCHCORDS
PREMIUM TYPE PATCHCORDS
Attenuation Of random taken connections dBAcc. IEC 61300-3-34
Attenuation Towards reference connector dBAcc. IEC 61300-3-4 Acc. IEC61300-3-6
Connectors SM: ST, SC, FC, LC, E2000, MU, DIN
Connectors SM APC: SC/APC, FC/APC, LC/APC, E2000/APC, MU/APC, DIN/APC
» Terminations: FC, SC, ST, MU, LC, D4, DIN, E2000, MT-RJ, MPO, SMA, E2000, FDDI, and ESCON
» Fiber diameter (mm): Φ 0.9, φ 2.0, Φ 3.0 and customized size » Fiber type: Single mode (G. 652, G655), multimode (50/125) /
(62.5/125), OM3, OM4 » Types: single mode, multimode » Insertion Loss (dB): less than 0.2 (PC and UPC) » Return Loss (dB): more than 0.50 (PC and UPC) » Exchangeability: less than 0.15 dB » Tensile Strength: less than 0.2 dB (0 to15 kgf ) » Temp. Range: (- 40 to +85 degree centigrade) » Types: PC, UPC, APC » Radius of Curvature: 10 to 25 mm, 5 to 15 mm » Apex O�set: ≤50 um; ≤100 um » Fiber Spherical Height: -90 nm, +50 nm » Angular O�set: 8°± 0.5°C (APC)
» High quality and transmission parameters repeatability » Compliance with norms: EN-50173-1 EIA/TIA 568,EN 50377
& Telcordia GR-326, GR-20, IEC 60793-2-10, TIA/EIA-492CAAB Standarts
SPECIFICATIONS
CHARACTERISTICS
SM Single Mode• G652D Fiber with low water peak• G655 NZDS fiber for CWDW and
DWDM transmissions• G656 NZDS fiber for CWDW and
DWDM transmissions• G657A Fiber with low bending radius
for FTTH Networks,compatible with G652 • G657B Fiber with low bending radius
for FTTH Networks
IL conn.-conn.97%≤0,15 dBAverage ≤ 0,07 dB
IL conn.-conn.97%≤0,15 dBAverage ≤ 0,07 dB
IL max.≤0,15 dB
IL max.≤0,15 dB
RL UPC >50
RL APC > 65
TECHNICAL DATA, PARAMETERS
PATCHCORDS
TKS-FOM-30/ TKS-FOM-090601214001
TKS-FOM-31/TKS-FOM-120601214001
turksat.com.tr |
Turksat Code / TTAF Con�rmation Code TTAF Code
FO-05774AASX20001
E2000/APC-E2000/APC 9/125 SM SX L:1
Turksat Code / TTAF Con�rmation Code TTAF Code
FO-05774AASX20003
E2000/APC-E2000/APC 9/125 SM SX L:3
Turksat Code / TTAF Con�rmation Code TTAF Code
FO-05774AASX20005
E2000/APC-E2000/APC 9/125 SM SX L:5
Turksat Code / TTAF Con�rmation Code TTAF Code
FO-05774AASX20010
E2000/APC-E2000/APC 9/125 SM SX L:10
LowIns.loss
UL 94 V-0
Highquality
FIBER OPTIC PATCHCORDS9/125 SINGLE MODE SIMPLEX PATCHCORDS LS
ZH
PATCHCORDS
SC/APC-LC/APC 9/125 SM SX L:1
SC/APC-LC/APC 9/125 SM SX L:3
LC/APC-LC/APC 9/125 SM SX L:1
LC/APC-LC/APC 9/125 SM SX L:3
TKS-FOM-42 FO-05244AASX20001
TKS-FOM-44 FO-05244AASX20001
TKS-FOM-43 FO-05244AASX20001
TKS-FOM-45 FO-05244AASX20001
turksat.com.tr |
FIBER OPTIC SPECIAL PATCHCORDSARMORED & FAN-OUT PATCHCORDS
• Other than MTRJ, ESCON, FDDI any connectors can be used.
• Supressing endurance is 25times stronger than Standard patchcords.
• It is ideal for versus rodents.
• Simplex cable thickness can be reduced to 2.8mm
• Armored integrity is fully provided for duplex and fan-out applications.
With stainless steel tube inside the outher jacket to protect the central unit of the cable, the armored fiber optic patchcords are easy to use in harsh invironment, what is more, they are flexible as well, handling these armored fiber optic patch cables are as easy as handling electric cables.
Armored fiber optic patch cable retain all the features of standard patchcord, but they are much more stronger. The armored fiber optic patch cables will not get damage even it is stepped by an adult, and they are anti-rodents, when they use such armored fiber optic patchcord, people do not need to worry that the rodent animals like the rats may bite the cables and make them broken.
Although armored fiber optic cables are strong, they are actually as flexible as standard fiber optic patchcords; they can be bend randomly without being broken. Armored fiber optic patchcord can be made similar outer diameter with the standard patchcords, this make them space saving. What is more, they can be with di�erent jacket colors and jacket types such as OFNR etc, and they are actually light weight also can be with SC, ST, FC, LC,MU,SC/APC, ST/APC, FC/APC, LC/APC etc types of terminations. TTAF’s armored fiber optic patch cables are designed for being used in harsh environment, in which the traditional standard fiber optic patch cable can not fit and can not get good perfomance. They are made with special strong connectors and armored fiber optic cables can protect the cable from damage caused by twist, pressure or rodent bite. Installation procedure and maintenance is also easy. They are ideal choice for people who is looking for fiber optic patchcords with addtional durability and protection as well as light weight.
• Si
mpl
ex a
rmor
ed c
able
OD
3.4
mm
• D
uple
x ar
mor
ed c
able
OD
2.8
mm
• 4
core
arm
ored
cab
le O
D 3
.3m
m
• Si
mpl
ex a
rmor
ed c
able
OD
2.0
mm
• Si
mpl
ex a
rmor
ed c
able
OD
2.4
mm
• D
uple
x ar
mor
ed c
able
OD
2.8
mm
• 4
core
arm
ored
tact
ical
cab
le
• Si
mpl
ex a
rmor
ed c
able
OD
2.0
mm
ALT
ERN
ATIV
E CA
BLE
TYPE
S FO
R A
RMO
RED
PAT
CHCO
RDS
Insertion LossReturn LossStorage TemperatureWorking TemperatureRepeatability of ILService Life
0.2 dB55 dB
-40 C to +90 C-40 C to +85 C
0.2 dB75 dB
-40 C to +90 C-40 C to +85 C
0.1 dB1000 mate/demate cycles
0.2 dB45 dB
-40 C to +90 C-40 C to +85 C
SINGLE MODE SINGLE MODE MULTI MODE TYPE
PATCHCORDS
turksat.com.tr |
PATCHCORDS & PIGTAILS
LowIns.loss
UL 94 V-0
Highquality
Fan-Out Patchcords
LSZH
• in all requested lenghts with SC, LC, FC etc. connectors.
• deployment and improve connection reliability.
• Field-installable cable modules easily mount on to front of the ODF’s via cable management parts.
Armored ExpandedBeam to PC
Armored Fan-outPatchcords
FIBER OPTIC SPECIAL PATCHCORDS
Turksat Code / TTAF Con�rmation Code TTAF Code
FO-05224AASX30003ZTKS-FOM-27/TKS-FOM-2706012014002
SC/APC-SC/APC 9/125 SM SX L:3 (ARMORED)Turksat Code / TTAF Con�rmation Code TTAF Code
FO-0424ASX30003ZTKS-FOM-28TKS-FOM-2806012014002
SCA/APC 9/125 SM SX L:3 PIGTAIL (ARMORED)
turksat.com.tr |
PATCHCORDS
• Gigabit Ethernet• Telecommunication Networks • Active Device Termination• Video • Industrial • Multimedia• Military• Premise Installations
Application
Features
• Manufactured by armoured optical Cable,flexible metal tube protect the Fiber optic
• High pres resistant strength,stamp Resistant and anti bite of rat ant.• Small diameter,bend resistant and Optimum flexible.• Aramid yarn reinforced optical cable Has superior elnogate resistant,and
Secured and reliable when connect it with fiber optic connector.• Can put directly at various environment• Indoor,no need for using protection Conduct, and convenient for network• Operation and maintenance.
Optical Performance
Type Single Mode (APC polish ) Multimode (PC /Flat Polish)
Insertion Loss ≤ 0.2 db ≤ 0.2 db
Return Loss PC > 45 dB UPC > 55 dB APC > 65 dB
UPC > 55 dB
Repeatability ≤ 0.1 db ≤ 0.1 db
Durability ≤ 0.2 dB -≤ 0.2 dB
Interchangeability ≤ 0.1 dB ≤ 0.1 dB
Tensile Strenght > 15 kg. > 15 kg.
Operating Temperature -40 °C to 85 °C -40 °C to 85 °C
Storage Temperature -40 °C to 85 °C -40 °C to 85 °C
ARMOREDPATCHCORDS
turksat.com.tr |
PATCHCORDS
FIBER OPTIC SPECIAL PATCHCORDSRRU FIBER - BRANCH CABLE ( SINGLE MODE )
SPECIFICATIONS
• Jacket of Fiber: (FR) PE, LSZH• Fiber Type: G657A2B2• 2 Fiber or 4 Fiber upon request• Water and dustproof, comply with IP 67• LC, SC, MU, etc.. connector option• Tensile force > 300N• Insertion Loss: Typical 0.25 dB / km @1310 nm• Return Loss ( for single mode ) : > 50 dB for UPC, > 65 dB for APC• Working Temperature: -40 C / +85 C• Minimum installation temperature: -15 C / +60 C• Storage temperature: -40 C / +70 C
APPLICATIONS&
FEATURES
FIBER OPTIC SYSTEMS ®
• 3G 4G base station used • Equipment diagnosis • FTTA ,FTTP, FTTX,WIMAX• BBU, RRU, RRH, LTE
• The item used for outdoor RRU transmitting optical signal and remote fiber feeder etc; saftly screwing connecting ;
• Protection Level reach IP67
• Low insertion/return loss,steady optical transmitting.
9/125 SINGLE MODECable assembly intended for FTTA, for indoor and outdoor use. The cable is terminated with LC du-
black, OD=4.8±0.2mm.
RRU BRANCHCABLE
turksat.com.tr |
PATCHCORDS
LowIns.loss
UL 94 V-0
Highquality
LSZH
FO-05554PPDX70XXX DLC/DLC 9/125 SM DX 7mm. L: x meter Patchcord
FO-05254PPDX70XXX DSC/DLC 9/125 SM DX 7mm. L: x meter Patchcord
FO-05224PPDX70XXX DSC/DSC 9/125 SM DX 7mm. L: x meter Patchcord
Art No Product Description FIBER OPTIC SYSTEMS ®
CONNECTOR SPECIFICATIONS
• Insertion Loss ≤ 0.2 dB ≥ 0.2 dB• Return Loss 55 dB 55 dB• Endurance 1000 times. 1000 times.• Other parameters
meet standard GR326 GR326
CONNECTOR A CONNECTOR B
FIBER OPTIC SPECIAL PATCHCORDSRRU FIBER - BRANCH CABLE ( SINGLE MODE )
turksat.com.tr |
» SC, LC, ST, FC and E2000 connectors » UPC and APC interface » Low smoke zero halogen (LSZH) secondary bu�er » » ITU G.652.D, TIA/EIA 492CAAB » Bend insensitive ITU G.657.A1 or ITU G.657.A2 » Di�erent connector performance range for specific application » Available in standard white colour bu�er and also in standard 12
colours as per IEC 60304 » Available in standard and blister packing
» OPTICAL PERFORMANCE » IL Max/Master(Acceptance) » Ave/Master* » Ave/Random* » Return Loss
» CHARACTERISTICS » Crush » Operating Temperature » Nominal bu�er Diameter » Max Tensile Load
» CHARACTERISTICS » Attenuation (dB) / km » Chromatic Dispersion (ps/nm x km) » Polarization Mode Dispersion (ps/√km)
SINGLEMODE0,25 dB0,18dB0,18dB50/60
UNITSN/100mm°C
N
0.38 @ 1310nm / 0.25 @ 1550nm3.0 @ 1310nm / 18.0 @ 1550nm≤ 0.2
CONFORMANCEIEC 61300-3-4IEC 61300-3-4IEC 61300-3-34IEC 61300-3-6
SIMPLEX500~20 to 60900+506
FEATURES
CONNECTOR SPECIFICATION
BUFFER SPECIFICATION
Fiber SPECIFICATION
TTAF® singlemode pigtails are used in telecom, cable tv networks and also used for high speed
Telecordia standards. The singlemode pigtails are terminated with standard TTAF® connector which gives optimum optical performance.
» Telecom and datacom application » Patch panels, wall boxes, ODFs and splice cassettes » Easy strip pigtails for on site installation » Supports high speed multi channel video, data and voice
services in metropolitan and access networks » ATM, SONET and WDM
APPLICATION
FIBER OPTIC PIGTAILS
PIGTAILS
PIGTAILS
9/125 OS1 OPTICAL FIBER PIGTAILS
TKS-FOM-32-1506012014001
k