Fiber Optic Cables 2018

144
Fiber Opc Cables 2018 Reichle & De-Massari Czech Republic a.s. R&M offers a broad range of fiber opc cables for applicaons in Local Area Networks, Data Centers and Telecom. 030.5943

Transcript of Fiber Optic Cables 2018

Page 1: Fiber Optic Cables 2018

Fiber Optic Cables 2018Reichle & De-Massari Czech Republic a.s. R&M offers a broad range of fiber optic cables for applications in Local Area Networks, Data Centers and Telecom.

030.

5943

Page 2: Fiber Optic Cables 2018

2

R&M generates added value. Connectivity that matters.

Our motto: Experience – Quality – Flexibility!

Experience We have carefully selected staff with long time experience at designing and manufacturing of fibre optic cables.

Quality All used materials are subjected to input con-trol. Every production process is finished by measurement of each fibre, complete cables then by complex output-control documented always by Final Test Protocol, which is integral part of each supplied cable.

FlexibilityWe are prepared to offer cables according to your needs in the shortest possible term, of course.

We are focussed on manufacture of flame-re-tardant to EN 60332-3 and fire-resistant to EN 60331-25 loose-tube constructions tested in accordance with IEC 60794-1-2 standard.

Loose-tube cables can contain either one single tube with coloured optical fibres (central-loose-tube = CLT), either multiple tubes (Multi Loose Tube = MLT). We use either FRLSZH (Fire-Re-tardant, Low-Smoke, Zero-Halogen) jacketing compounds for indoor or universal (indoor/outdoor) installation either PE (Polyethylene) compounds for outdoor installation as well as other special compounds.

Reichle & De-Massari Czech Republic a.s. offers range of cable constructions with increased resistance to mechanical damage (like Steel-Wire-Armoured or Corrugated-Steel-Tape armoured) suitable for direct burial installation.

Production of Fibre Optic Cables

Page 3: Fiber Optic Cables 2018

3

Reichle & De-Massari Czech Republic a.s.

Sales Support

František MaczákSales Manager – FOC+420 737 220 [email protected]

Zuzana MichalscakovaInside Sales Manager – FOC+420 412 548 [email protected]

Reichle & De-Massari Czech Republic a.s.Vítězství 67405 02 Děčín 33 – Nebočadywww.rdm-czech.com

Product Management

Lars ZuelligProduct Manager – FOC+41 44 933 84 [email protected]

Reichle & De-Massari AG – HeadquartersBinzstrasse 328620 Wetzikon – Switzerlandwww.rdm.com

About us

Transportkabel-DIXI Inc. has been founded in 1996 as a supplier of technologies and machinery for the cable manufacturing and cable handling. The Company processes his own construction, engineer-ing and manufacturing capacities including his own production and testing line. The Company is also closely cooperating with cable manufacturing plants.

In beginning of 2018 Reichle & De-Massari (R&M), the Swiss developer and provider of connectivity systems for network infra-structure has acquired Transportkabel – DIXI (TK DIXI) in order to enhance its end-to-end fibre optic cable offering. Founded more than 20 years ago, R&M develops and manufactures fibre optic and metallic cables for power and communication applications in data centres, broadband networks, enterprise buildings and other infrastructure projects.

Page 4: Fiber Optic Cables 2018

4

Content. Fiber Optic cable assortment.

030.5912

Page 5: Fiber Optic Cables 2018

5

Central Loose Tube Cables – CLT 6Overview 8

Microcables 12

All-dielectric Duct Cables 20

All-dielectric Duct Cables with improved rodent protection 28

Steel Wire Armoured Cables – SWA 36

Corrugated Steel Tape Armoured Cables – CSTA 42

Fiber Reinforced Plastic Rod Armoured Cables – FRPA 52

Fire Resistant Cables – All-dielectric Non-armoured 56

Fire Resistant Cables – Corrugated Steel Tape Armoured 60

Fire Resistant Cables – Steel Wire Armoured Cables 64

Multi Loose Tube Cables – MLT 70Overview 72

Microcables 76

All-dielectric Duct Cables 82

All-dielectric Duct Cables with improved rodent protection 90

Steel Wire Armoured Cables – SWA 98

Corrugated Steel Tape Armoured Cables – CSTA 102

Fire Resistant Cables – All-dielectric Non-armoured 110

Fire Resistant Cables – Corrugated Steel Tape Armoured 112

Fire Resistant Cables – Steel Wire Armoured Cables 114

FTTx Constructions 116Overview 118

Microcables 120

Flat self-supporting cables 122

Non-metallic drop cables 126

Sensor Cables 130

Explanations 134Fiber specifications 135

DIN/VDE 0888 cable coding 136

Color codes 137

Coding of FOC constructions 138

CPR 140

Page 6: Fiber Optic Cables 2018

6

R&M generates added value. Connectivity that matters.Central Loose Tube Cables. CLT.

Page 8: Fiber Optic Cables 2018

8

R&M generates added value. Connectivity that matters.

Central Loose Tube Cables Overview

Microcables

MT1H 12 MT1H xx.yy.zz.c outdoor 12 fibers HDPE

MX1H 14 MX1H xx.yy.zz.c outdoor 24 fibers HDPE

MT1F 16 MT1F xx.yy.zz.c indoor/outdoor 12 fibers FRLSZH

MX1F 18 MX1F xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH

All-dielectric duct cables with standard rodent protection

OT1EL 20 OT1EL xx.yy.zz.c outdoor 12 fibers LDPE

OX1EL 22 OX1EL xx.yy.zz.c outdoor 24 fibers LDPE

UT1EF 24 UT1EF xx.yy.zz.c indoor/outdoor 12 fibers FRLSZH

UX1EF 26 UX1EF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH

All-dielectric duct cables with improved rodent protection

OT1GL 28 OT1GL xx.yy.zz.c outdoor 12 fibers LDPE

OX1GL 30 OX1GL xx.yy.zz.c outdoor 24 fibers LDPE

UT1GF 32 UT1GF xx.yy.zz.c indoor/outdoor 12 fibers FRLSZH

UX1GF 34 UX1GF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH

Steel wire armoured cables – SWA

OX1ELWH 36 OX1ELWH xx.yy.zz.c outdoor 24 fibers HDPE

UX1ELWF 38 UX1ELWF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH

UX1EFWF 40 UX1EFWF xx.yy.zz.c indoor/outdoor

Corrugated steel tape armoured cables, single jacketed – CSTA

OX1ECH 42 OX1ECH xx.yy.zz.c outdoor 24 fibers HDPE

UX1ECF 44 UX1ECF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH

Corrugated steel tape armoured cables, double jacketed – CSTA

OX1ELCH 46 OX1ELCH xx.yy.zz.c outdoor 24 fibers HDPE

UX1ELCF 48 UX1ELCF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH

UX1EFCF 50 UX1EFCF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH

Cable type Construction Page Construction code Application Fiber count Jacket material Euro classification to CPR

Nominal cable Ø [mm]

Cable weight [kg/km]

Tensile performance [N]

Crush [N/100mm]

Temperatur range in operation

Fire resistance – EN 60331-25

Page 9: Fiber Optic Cables 2018

9

Microcables

MT1H 12 MT1H xx.yy.zz.c outdoor 12 fibers HDPE

MX1H 14 MX1H xx.yy.zz.c outdoor 24 fibers HDPE

MT1F 16 MT1F xx.yy.zz.c indoor/outdoor 12 fibers FRLSZH

MX1F 18 MX1F xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH

All-dielectric duct cables with standard rodent protection

OT1EL 20 OT1EL xx.yy.zz.c outdoor 12 fibers LDPE

OX1EL 22 OX1EL xx.yy.zz.c outdoor 24 fibers LDPE

UT1EF 24 UT1EF xx.yy.zz.c indoor/outdoor 12 fibers FRLSZH

UX1EF 26 UX1EF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH

All-dielectric duct cables with improved rodent protection

OT1GL 28 OT1GL xx.yy.zz.c outdoor 12 fibers LDPE

OX1GL 30 OX1GL xx.yy.zz.c outdoor 24 fibers LDPE

UT1GF 32 UT1GF xx.yy.zz.c indoor/outdoor 12 fibers FRLSZH

UX1GF 34 UX1GF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH

Steel wire armoured cables – SWA

OX1ELWH 36 OX1ELWH xx.yy.zz.c outdoor 24 fibers HDPE

UX1ELWF 38 UX1ELWF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH

UX1EFWF 40 UX1EFWF xx.yy.zz.c indoor/outdoor

Corrugated steel tape armoured cables, single jacketed – CSTA

OX1ECH 42 OX1ECH xx.yy.zz.c outdoor 24 fibers HDPE

UX1ECF 44 UX1ECF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH

Corrugated steel tape armoured cables, double jacketed – CSTA

OX1ELCH 46 OX1ELCH xx.yy.zz.c outdoor 24 fibers HDPE

UX1ELCF 48 UX1ELCF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH

UX1EFCF 50 UX1EFCF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH

3.0 8.0 50 500 -20°C to 70°C

4.0 14.0 50 500 -20°C to 70°C

Fca 3.0 10.0 50 500 -30°C to 70°C

Fca 4.0 17.0 50 500 -30°C to 70°C

5.8 29.0 1'000 2'000 -20°C to 70°C

6.5 37.0 1'000 2'000 -20°C to 70°C

Dca-s2,d1,a1 5.2 33.0 1'000 2'000 -30°C to 70°C

Dca-s2,d1,a1 5.8 41.0 1'000 2'000 -30°C to 70°C

6.5 37.0 1'800 2'000 -20°C to 70°C

7.4 50.0 2'000 2'000 -20°C to 70°C

Dca-s2,d1,a1 6.2 45.0 1'800 2'000 -30°C to 70°C

Dca-s2,d1,a1 7.2 58.0 2'000 2'000 -30°C to 70°C

9.9 150.0 4'500 4'000 -20°C to 70°C

Fca 9.9 170.0 4'500 4'000 -20°C to 70°C

Dca-s2,d2,a1 9.9 180.0 4'500 4'000 -30°C to 70°C

7.7 70.0 1'500 5'000 -20°C to 70°C

Dca-s2,d2,a1 7.7 84.0 1'500 5'000 -30°C to 70°C

10.0 100.0 1'500 5'000 -20°C to 70°C

Fca 10.0 115.0 1'500 5'000 -30°C to 70°C

Cca-s1,d0,a1 10.0 125.0 1'500 5'000 -30°C to 70°C

Cable type Construction Page Construction code Application Fiber count Jacket material Euro classification to CPR

Nominal cable Ø [mm]

Cable weight [kg/km]

Tensile performance [N]

Crush [N/100mm]

Temperatur range in operation

Fire resistance – EN 60331-25

Page 10: Fiber Optic Cables 2018

10

R&M generates added value. Connectivity that matters.

Central Loose Tube Cables Overview

Fiber reinforced plastic rod armoured cables – FRPA

OX1PH 52 OX1PH xx.yy.zz.c outdoor 24 fibers HDPE

UX1PF 54 UX1PF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH

Fire resistant cables – All-dielectric, non-armoured

QT1GF 56 QT1GF xx.yy.zz.c indoor/outdoor 12 fibers FRLSZH

QX1GF 58 QX1GF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH

Fire resistant cables – Corrugated steel tape armoured – CST

QX1ECF 60 QX1ECF xx.yy.zz.c indoor/outdoor 12 fibers FRLSZH

QX1EFCF 62 QX1EFCF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH

Fire resistant cables – Steel wire armoured cables – SWA

QX1EFWF 64 QX1EFWF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH

QX1ELWF 66 QX1ELWF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH

QX1EFWFc 68 QX1EFWFc xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH

Cable type Construction Page Construction code Application Fiber count Jacket material Euro classification to CPR

Nominal cable Ø [mm]

Cable weight [kg/km]

Tensile performance [N]

Crush [N/100mm]

Temperatur range in operation

Fire resistance – EN 60331-25

Page 11: Fiber Optic Cables 2018

11

7.4 52.0 2'500 3'000 -20°C to 70°C

Fca 7.4 65.0 2'500 3'000 -30°C to 70°C

Dca-s1,d1,a1 7.0 58.0 2'000 2'000 -30°C to 70°C 180 min at 750°C

Dca-s2,d1,a1 7.8 68.0 2'000 2'000 -30°C to 70°C 180 min at 750°C

Fca 8.0 90.0 1'500 5'000 -30°C to 70°C 180 min at 750°C

Fca 11.0 150.0 1'500 5'000 -30°C to 70°C 180 min at 750°C

Fca 10.1 185.0 4'500 4'000 -20°C to 70°C 180 min at 750°C

Fca 10.1 185.0 4'500 4'000 -20°C to 70°C 180 min at 750°C

Fca 10.1 185.0 4'500 4'000 -20°C to 70°C 180 min at 750°C

Fiber reinforced plastic rod armoured cables – FRPA

OX1PH 52 OX1PH xx.yy.zz.c outdoor 24 fibers HDPE

UX1PF 54 UX1PF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH

Fire resistant cables – All-dielectric, non-armoured

QT1GF 56 QT1GF xx.yy.zz.c indoor/outdoor 12 fibers FRLSZH

QX1GF 58 QX1GF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH

Fire resistant cables – Corrugated steel tape armoured – CST

QX1ECF 60 QX1ECF xx.yy.zz.c indoor/outdoor 12 fibers FRLSZH

QX1EFCF 62 QX1EFCF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH

Fire resistant cables – Steel wire armoured cables – SWA

QX1EFWF 64 QX1EFWF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH

QX1ELWF 66 QX1ELWF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH

QX1EFWFc 68 QX1EFWFc xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH

Cable type Construction Page Construction code Application Fiber count Jacket material Euro classification to CPR

Nominal cable Ø [mm]

Cable weight [kg/km]

Tensile performance [N]

Crush [N/100mm]

Temperatur range in operation

Fire resistance – EN 60331-25

Page 12: Fiber Optic Cables 2018

12

R&M generates added value. Connectivity that matters.Cable construction code DIN code

MT1H xx.yy.zz.c A-D2Y

1. Gel filled PBT loose tube with optical fibers2. HDPE UV stable outer jacket

Cable general description

Max. 12 fiber uni-tube non-metallic micro-cable for outdoor installation to micro-tubes.

Construction and dimensions

Loose tube nominal diameter 2,0 mm

Outer jacket nominal thickness 0,5 mm

Cable nominal outer diameter 3,0 mm

Cable informative weight 8 kg/km

Standard put-up length 2100/4100 m ± 5%

Outer jacket

Material UV stable HDPE

Jacket colour Black

Sheath marking Ink-Jet, white

Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

Microcables MT1H

Page 13: Fiber Optic Cables 2018

13

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1 50 N (short term) Δα ≤ 0,05 dB after test

Crush EN 60794-1-21:E3A 500 N/100mm (short term) Δα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 1 Nm, 3 impacts, d=20 mm,R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R = 40 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Kink EN 60794-1-21:E10 d = 40 x cable diameter no damage

Bend no tension EN 60794-1-21:E11A R=40 x cable diameter, 4 turns,3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -20°C ÷ 70°C-30°C ÷ 70°C

Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible

Temperature range of use

-5°C ÷ 50°C-20°C ÷ 70°C-30°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage

* EN 60794-5-10 Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1

MT1H Ø 3,0

4 01.04.M3.B 01.04.M4.B 01.04.M5.B 01.04.S2.B 01.04.S7.B

6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B

8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B

12 01.12.M3.B 01.12.M4.B 01.12.M5.B R848278 01.12.S7.B

Order code e.g.: MT1H 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Central Loose Tube Cables

Page 14: Fiber Optic Cables 2018

14

R&M generates added value. Connectivity that matters.Cable construction code DIN code

MX1H xx.yy.zz.c A-D2Y

1. Gel filled PBT loose tube with optical fibers2. HDPE UV stable outer jacket

Cable general description

Max. 24 fiber uni-tube non-metallic micro-cable for outdoor installation to micro-tubes.

Construction and dimensions

Loose tube nominal diameter 3,0 mm

Outer jacket nominal thickness 0,5 mm

Cable nominal outer diameter 4,0 mm

Cable informative weight 14 kg/km

Standard put-up length 2100/4100 m ± 5%

Outer jacket

Material UV stable HDPE

Jacket colour Black

Sheath marking Ink-Jet, white

Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

Microcables MX1H

Page 15: Fiber Optic Cables 2018

15

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1 50 N (short term) Δα ≤ 0,05 dB after test

Crush EN 60794-1-21:E3A 500 N/100mm (short term) Δα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 1 Nm, 3 impacts, d=20 mm,R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R = 40 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Kink EN 60794-1-21:E10 d = 40 x cable diameter no damage

Bend no tension EN 60794-1-21:E11A R=40 x cable diameter, 4 turns,3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -20°C ÷ 70°C-30°C ÷ 70°C

Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible

Temperature range of use

-5°C ÷ 50°C-20°C ÷ 70°C-30°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage

* EN 60794-5-10 Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1

MX1H Ø 4,0

16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B

20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B

24 01.24.M3.B 01.24.M4.B 01.24.M5.B R848279 01.24.S7.B

Order code e.g.: MX1H 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Central Loose Tube Cables

Page 16: Fiber Optic Cables 2018

16

R&M generates added value. Connectivity that matters.Cable construction code DIN code

MT1F xx.yy.zz.c J/A-DH

1. Gel filled PBT loose tube with optical fibers2. FRLSZH UV stable outer jacket

Cable general description

Max. 12 fiber uni-tube non-metallic micro-cable for indoor or outdoor installation to micro-tubes.

Construction and dimensions

Loose tube nominal diameter 2,0 mm

Outer jacket nominal thickness 0,5 mm

Cable nominal outer diameter 3,0 mm

Cable informative weight 10 kg/km

Standard put-up length 2100/4100 m ± 5%

Outer jacket

Material UV stable FRLSZH

Jacket colour Black. Other colours available on request

Sheath marking Ink-Jet, white or black depending on the jacket colour

Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

Microcables MT1F

Page 17: Fiber Optic Cables 2018

17

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1 50 N (short term) Δα ≤ 0,05 dB after test

Crush EN 60794-1-21:E3A 500 N/100mm (short term) Δα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 1 Nm, 3 impacts, d=20 mm,R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R = 40 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Kink EN 60794-1-21:E10 d = 40 x cable diameter no damage

Bend no tension EN 60794-1-21:E11A R=40 x cable diameter, 4 turns,3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -30°C ÷ 70°C-35°C ÷ 70°C

Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible

Temperature range of use

-5°C ÷ 50°C-30°C ÷ 70°C-35°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage

* EN 60794-5-10

Fire performance

Euro classification to CPR EN 50575, EN 13501-6 Fca

Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1

MT1F Ø 3,0 Fca

4 01.04.M3.B 01.04.M4.B 01.04.M5.B 01.04.S2.B 01.04.S7.B

6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B

8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B

12 01.12.M3.B R848280 01.12.M5.B 01.12.S2.B R848281

Order code e.g.: MT1F 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Central Loose Tube Cables

Page 18: Fiber Optic Cables 2018

18

R&M generates added value. Connectivity that matters.Cable construction code DIN code

MX1F xx.yy.zz.c J/A-DH

1. Gel filled PBT loose tube with optical fibers2. FRLSZH UV stable outer jacket

Cable general description

Max. 24 fiber uni-tube non-metallic micro-cable for indoor or outdoor installation to micro-tubes.

Construction and dimensions

Loose tube nominal diameter 3,0 mm

Outer jacket nominal thickness 0,5 mm

Cable nominal outer diameter 4,0 mm

Cable informative weight 17 kg/km

Standard put-up length 2100/4100 m ± 5%

Outer jacket

Material UV stable FRLSZH

Jacket colour Black. Other colours available on request

Sheath marking Ink-Jet, white or black depending on the jacket colour

Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

Microcables MX1F

Page 19: Fiber Optic Cables 2018

19

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1 50 N (short term) Δα ≤ 0,05 dB after test

Crush EN 60794-1-21:E3A 500 N/100mm (short term) Δα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 1 Nm, 3 impacts, d=20 mm,R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R = 40 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Kink EN 60794-1-21:E10 d = 40 x cable diameter no damage

Bend no tension EN 60794-1-21:E11A R=40 x cable diameter, 4 turns,3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -30°C ÷ 70°C-35°C ÷ 70°C

Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible

Temperature range of use

-5°C ÷ 50°C-30°C ÷ 70°C-35°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage

* EN 60794-5-10

Fire performance

Euro classification to CPR EN 50575, EN 13501-6 Fca

Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1

MX1F Ø 4,0 Fca

16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B

20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B

24 01.24.M3.B R848282 01.24.M5.B 01.24.S2.B R848283

Order code e.g.: MX1F 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Central Loose Tube Cables

Page 20: Fiber Optic Cables 2018

20

R&M generates added value. Connectivity that matters.Cable construction code DIN code

OT1EL xx.yy.zz.c A-DQ(ZN)2Y wbg

1. Gel filled PBT loose tube with optical fibers2. Water-blocking e-glass yarn3. LDPE UV stable outer jacket

Cable general description

Max. 12 fiber uni-tube non-metallic cable with standard level of rodent protection for outdoor duct installation.

Construction and dimensions

Loose tube nominal diameter 2,8 mm

Outer jacket nominal thickness 1,0 mm

Cable nominal outer diameter 5,8 mm

Cable informative weight 29 kg/km

Standard put-up length 2100/4100 m ± 5%

Outer jacket

Material UV stable LDPE

Jacket colour Black

Sheath marking Ink-Jet, white

Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

All-dielectric Duct Cables OT1EL

Page 21: Fiber Optic Cables 2018

21

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1 300 N (long term) 1000 N (short term)

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

Crush EN 60794-1-21:E3A 1000 N/100mm (long term)2000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 10 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -20°C ÷ 70°C-25°C ÷ 70°C

Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible

Temperature range of use

-5°C ÷ 50°C-20°C ÷ 70°C-25°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage

* EN 60794-3-10, EN 60794-3-11 Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1

OT1EL Ø 5,8

4 01.04.M3.B 01.04.M4.B 01.04.M5.B 01.04.S2.B 01.04.S7.B

6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B

8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B

12 01.12.M3.B 01.12.M4.B 01.12.M5.B R848284 01.12.S7.B

Order code e.g.: OT1EL 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Central Loose Tube Cables

Page 22: Fiber Optic Cables 2018

22

R&M generates added value. Connectivity that matters.Cable construction code DIN code

OX1EL xx.yy.zz.c A-DQ(ZN)2Y wbg

1. Gel filled PBT loose tube with optical fibers2. Water-blocking e-glass yarn3. LDPE UV stable outer jacket

Cable general description

Max. 24 fiber uni-tube non-metallic cable with standard level of rodent protection for outdoor duct installation.

Construction and dimensions

Loose tube nominal diameter 3,5 mm

Outer jacket nominal thickness 1,1 mm

Cable nominal outer diameter 6,5 mm

Cable informative weight 37 kg/km

Standard put-up length 2100/4100 m ± 5%

Outer jacket

Material UV stable LDPE

Jacket colour Black

Sheath marking Ink-Jet, white

Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

All-dielectric Duct Cables OX1EL

Page 23: Fiber Optic Cables 2018

23

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1 300 N (long term) 1000 N (short term)

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

Crush EN 60794-1-21:E3A 1000 N/100mm (long term)2000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 10 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -20°C ÷ 70°C-25°C ÷ 70°C

Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible

Temperature range of use

-5°C ÷ 50°C-20°C ÷ 70°C-25°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage

* EN 60794-3-10, EN 60794-3-11 Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1

OT1EL Ø 6,5

16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B

20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B

24 01.24.M3.B 01.24.M4.B 01.24.M5.B R848285 01.24.S7.B

Order code e.g.: OT1EL 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Central Loose Tube Cables

Page 24: Fiber Optic Cables 2018

24

R&M generates added value. Connectivity that matters.Cable construction code DIN code

UT1EF xx.yy.zz.c J/A-DQ(ZN)H wbg

1. Gel filled PBT loose tube with optical fibers2. Water-blocking e-glass yarn3. FRLSZH UV stable outer jacket

Cable general description

Max. 12 fibre uni-tube non-metallic cable with standard rodent protection for indoor or outdoor duct installation.

Construction and dimensions

Loose tube nominal diameter 2,3 mm

Outer jacket nominal thickness 1,0 mm

Cable nominal outer diameter 5,2 mm

Cable informative weight 33 kg/km

Standard put-up length 2100/4100 m ± 5%

Outer jacket

Material UV stable FRLSZH

Jacket colour Black. Other colours available on request

Sheath marking Ink-Jet, white or black depending on the jacket colour

Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

All-dielectric Duct Cables UT1EF

Page 25: Fiber Optic Cables 2018

25

Order information

Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1

UT1EF Ø 5,2 Dca-s2,d1,a1

4 01.04.M3.B R848286 01.04.M5.B 01.04.S2.B 01.04.S7.B

6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B

8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B

12 01.12.M3.B R848287 01.12.M5.B R848288 R848289

Order code e.g.: UT1EF 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1 300 N (long term) 1000 N (short term)

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

Crush EN 60794-1-21:E3A 1000 N/100mm (long term)2000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 10 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -30°C ÷ 70°C-35°C ÷ 70°C

Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible

Temperature range of use

-5°C ÷ 50°C-30°C ÷ 70°C-35°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage

* EN 60794-3-10, EN 60794-3-11

Fire performance

Flammability - cable bundle EN 60332-3-22 (cat.A) Pass

Smoke density EN 61034-1, EN 61034-2 Pass

Halogen Free, Acid gases EN 60754-2 Pass

Euro classification to CPR EN 50575, EN 13501-6 Dca-s2,d1,a1

Cable expected lifetime / min. 30 years

Central Loose Tube Cables

Page 26: Fiber Optic Cables 2018

26

R&M generates added value. Connectivity that matters.Cable construction code DIN code

UX1EF xx.yy.zz.c J/A-DQ(ZN)H wbg

1. Gel filled PBT loose tube with optical fibers2. Water-blocking e-glass yarn3. FRLSZH UV stable outer jacket

Cable general description

Max. 24 fibre uni-tube non-metallic cable with standard rodent protection for indoor or outdoor duct installation.

Construction and dimensions

Loose tube nominal diameter 3,0 mm

Outer jacket nominal thickness 1,1 mm

Cable nominal outer diameter 5,8 mm

Cable informative weight 41 kg/km

Standard put-up length 2100/4100 m ± 5%

Outer jacket

Material UV stable FRLSZH

Jacket colour Black. Other colours available on request

Sheath marking Ink-Jet, white or black depending on the jacket colour

Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

All-dielectric Duct Cables UX1EF

Page 27: Fiber Optic Cables 2018

27

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1 300 N (long term) 1000 N (short term)

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

Crush EN 60794-1-21:E3A 1000 N/100mm (long term)2000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 10 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -30°C ÷ 70°C-35°C ÷ 70°C

Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible

Temperature range of use

-5°C ÷ 50°C-30°C ÷ 70°C-35°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage

* EN 60794-3-10, EN 60794-3-11

Fire performance

Flammability - cable bundle EN 60332-3-22 (cat.A) Pass

Smoke density EN 61034-1, EN 61034-2 Pass

Halogen Free, Acid gases EN 60754-2 Pass

Euro classification to CPR EN 50575, EN 13501-6 Dca-s2,d1,a1

Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1

UX1EF Ø 5,8 Dca-s2,d1,a1

16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B

20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B

24 01.24.M3.B R848290 01.24.M5.B R848352 R848353

Order code e.g.: UX1EF 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Central Loose Tube Cables

Page 28: Fiber Optic Cables 2018

28

R&M generates added value. Connectivity that matters.Cable construction code DIN code

OT1GL xx.yy.zz.c A-DQ(BN)2Y wbg

1. Gel filled PBT loose tube with optical fibers2. Water-blocking e-glass yarn3. LDPE UV stable outer jacket

Cable general description

Max. 12 fiber uni-tube non-metallic cable with improved level of rodent protection for outdoor duct installation.

Construction and dimensions

Loose tube nominal diameter 2,8 mm

Outer jacket nominal thickness 1,1 mm

Cable nominal outer diameter 6,5 mm

Cable informative weight 37 kg/km

Standard put-up length 2100/4100 m ± 5%

Outer jacket

Material UV stable LDPE

Jacket colour Black

Sheath marking Ink-Jet, white

Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

All-dielectric Duct Cables with improved rodent protection

OT1GL

Page 29: Fiber Optic Cables 2018

29

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1 600 N (long term) 1800 N (short term)

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

Crush EN 60794-1-21:E3A 1000 N/100mm (long term)2000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 10 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -20°C ÷ 70°C-25°C ÷ 70°C

Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible

Temperature range of use

-5°C ÷ 50°C-20°C ÷ 70°C-25°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage

* EN 60794-3-10, EN 60794-3-11 Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1

OT1GL Ø 6,5

4 01.04.M3.B 01.04.M4.B 01.04.M5.B 01.04.S2.B 01.04.S7.B

6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B

8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B

12 01.12.M3.B 01.12.M4.B 01.12.M5.B R848354 01.12.S7.B

Order code e.g.: OT1GL 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Central Loose Tube Cables

Page 30: Fiber Optic Cables 2018

30

R&M generates added value. Connectivity that matters.Cable construction code DIN code

OX1GL xx.yy.zz.c A-DQ(BN)2Y wbg

1. Gel filled PBT loose tube with optical fibers2. Water-blocking e-glass yarn3. LDPE UV stable outer jacket

Cable general description

Max. 24 fiber uni-tube non-metallic cable with improved level of rodent protection for outdoor duct installation.

Construction and dimensions

Loose tube nominal diameter 3,5 mm

Outer jacket nominal thickness 1,2 mm

Cable nominal outer diameter 7,4 mm

Cable informative weight 50 kg/km

Standard put-up length 2100/4100 m ± 5%

Outer jacket

Material UV stable LDPE

Jacket colour Black

Sheath marking Ink-Jet, white

Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

All-dielectric Duct Cables with improved rodent protection

OX1GL

Page 31: Fiber Optic Cables 2018

31

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1 600 N (long term) 2000 N (short term)

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

Crush EN 60794-1-21:E3A 1000 N/100mm (long term)2000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 10 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -20°C ÷ 70°C-25°C ÷ 70°C

Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible

Temperature range of use

-5°C ÷ 50°C-20°C ÷ 70°C-25°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage

* EN 60794-3-10, EN 60794-3-11 Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1

OX1GL Ø 7,4

16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B

20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B

24 01.24.M3.B 01.24.M4.B 01.24.M5.B R848355 01.24.S7.B

Order code e.g.: OX1GL 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Central Loose Tube Cables

Page 32: Fiber Optic Cables 2018

32

R&M generates added value. Connectivity that matters.Cable construction code DIN code

UT1GF xx.yy.zz.c J/A-DQ(BN)H wbg

1. Gel filled PBT loose tube with optical fibers2. Water-blocking e-glass yarn3. FRLSZH UV stable outer jacket

Cable general description

Max. 12 fiber uni-tube non-metallic cable with improved rodent protection for indoor or outdoor duct installation.

Construction and dimensions

Loose tube nominal diameter 2,3 mm

Outer jacket nominal thickness 1,1 mm

Cable nominal outer diameter 6,2 mm

Cable informative weight 45 kg/km

Standard put-up length 2100/4100 m ± 5%

Outer jacket

Material UV stable FRLSZH

Jacket colour Black. Other colours available on request

Sheath marking Ink-Jet, white or black depending on the jacket colour

Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

All-dielectric Duct Cables with improved rodent protection

UT1GF

Page 33: Fiber Optic Cables 2018

33

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1 600 N (long term) 1800 N (short term)

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

Crush EN 60794-1-21:E3A 1000 N/100mm (long term)2000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 10 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -30°C ÷ 70°C-35°C ÷ 70°C

Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible

Temperature range of use

-5°C ÷ 50°C-30°C ÷ 70°C-35°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage

* EN 60794-3-10, EN 60794-3-11

Fire performance

Flammability - cable bundle EN 60332-3-22 (cat.A) Pass

Smoke density EN 61034-1, EN 61034-2 Pass

Halogen Free, Acid gases EN 60754-2 Pass

Euro classification to CPR EN 50575, EN 13501-6 Dca-s2,d1,a1

Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1

UT1GF Ø 6,2 Dca-s2,d1,a1

4 01.04.M3.B R848356 01.04.M5.B 01.04.S2.B 01.04.S7.B

6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B

8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B

12 01.12.M3.B R848357 01.12.M5.B R848358 01.12.S7.B

Order code e.g.: UT1GF 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Central Loose Tube Cables

Page 34: Fiber Optic Cables 2018

34

R&M generates added value. Connectivity that matters.Cable construction code DIN code

UX1GF xx.yy.zz.c J/A-DQ(BN)H wbg

1. Gel filled PBT loose tube with optical fibers2. Water-blocking e-glass yarn3. FRLSZH UV stable outer jacket

Cable general description

Max. 24 fiber uni-tube non-metallic cable with improved rodent protection for indoor or outdoor duct installation.

Construction and dimensions

Loose tube nominal diameter 3,0 mm

Outer jacket nominal thickness 1,2 mm

Cable nominal outer diameter 7,2 mm

Cable informative weight 58 kg/km

Standard put-up length 2100/4100 m ± 5%

Outer jacket

Material UV stable FRLSZH

Jacket colour Black. Other colours available on request

Sheath marking Ink-Jet, white or black depending on the jacket colour

Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

All-dielectric Duct Cables with improved rodent protection

UX1GF

Page 35: Fiber Optic Cables 2018

35

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1 800 N (long term) 2000 N (short term)

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

Crush EN 60794-1-21:E3A 1000 N/100mm (long term)2000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 10 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -30°C ÷ 70°C-35°C ÷ 70°C

Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible

Temperature range of use

-5°C ÷ 50°C-30°C ÷ 70°C-35°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage

* EN 60794-3-10, EN 60794-3-11

Fire performance

Flammability - cable bundle EN 60332-3-22 (cat.A) Pass

Smoke density EN 61034-1, EN 61034-2 Pass

Halogen Free, Acid gases EN 60754-2 Pass

Euro classification to CPR EN 50575, EN 13501-6 Dca-s2,d1,a1

Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1

UX1GF Ø 7,2 Dca-s2,d1,a1

16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B

20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B

24 01.24.M3.B 01.24.M4.B 01.24.M5.B R848359 01.24.S7.B

Order code e.g.: UX1GF 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Central Loose Tube Cables

Page 36: Fiber Optic Cables 2018

36

R&M generates added value. Connectivity that matters.Cable construction code DIN code

OX1ELWH xx.yy.zz.c A-DQ(ZN)2YB2Y wbg (R 0,63vzk)

1. Gel filled PBT loose tube with optical fibers2. Water-blocking e-glass yarn3. LDPE UV stable inner jacket4. Zn galvanized steel wire armour fixed by PET tape5. Rip-cord6. HDPE UV stable outer jacket

Cable general description

Max. 24 fiber uni-tube steel wire armoured cable with two jackets for outdoor duct or direct buried installation. This cable construction offers excellent mechanical and full rodent protection.

Construction and dimensions

Loose tube nominal diameter 3,1 mm

Inner jacket nominal thickness 1,1 mm

Steel wire nominal diameter 0,63 mm

Outer jacket nominal thickness 1,3 mm

Cable nominal outer diameter 9,9 mm

Cable informative weight 150 kg/km

Standard put-up length 2100/4100 m ± 5%

Outer jacket

Material UV stable HDPE

Jacket colour Black

Sheath marking Ink-Jet, white

Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

Steel Wire Armoured Cables SWA

OX1ELWH

Page 37: Fiber Optic Cables 2018

37

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1 n.a. (long term) 4500 N (short term)

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

Crush EN 60794-1-21:E3A 2000 N/100mm (long term)4000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 20 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -20°C ÷ 70°C-25°C ÷ 70°C

Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible

Temperature range of use

-5°C ÷ 50°C-20°C ÷ 70°C-25°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage

* EN 60794-3-10, EN 60794-3-11 Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1

OX1EL Ø 9,9

4 01.04.M3.B 01.04.M4.B 01.04.M5.B 01.04.S2.B 01.04.S7.B

6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B

8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B

12 01.12.M3.B 01.12.M4.B 01.12.M5.B 01.12.S2.B 01.12.S7.B

16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B

20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B

24 01.24.M3.B 01.24.M4.B 01.24.M5.B R848360 01.24.S7.B

Order code e.g.: OX1ELWH 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Central Loose Tube Cables

Page 38: Fiber Optic Cables 2018

38

R&M generates added value. Connectivity that matters.Cable construction code DIN code

UX1ELWF xx.yy.zz.c J/A-DQ(ZN)2YBH wbg (R 0,63vzk)

1. Gel filled PBT loose tube with optical fibers2. Water-blocking e-glass yarn3. LDPE UV stable inner jacket4. Zn galvanized steel wire armour fixed by PET tape5. Rip-cord6. FRLSZH UV stable outer jacket

Cable general description

Max. 24 fiber uni-tube steel wire armoured cable with two jackets for indoor or outdoor duct or direct buried installation. This cable construction offers excellent mechanical and full rodent protection.

Construction and dimensions

Loose tube nominal diameter 3,0 mm

Inner jacket nominal thickness 1,1 mm

Steel wire nominal diameter 0,63 mm

Outer jacket nominal thickness 1,3 mm

Cable nominal outer diameter 9,9 mm

Cable informative weight 170 kg/km

Standard put-up length 2100/4100 m ± 5%

Outer jacket

Material UV stable FRLSZH

Jacket colour Black. Other colours available on request

Sheath marking Ink-Jet, white or black depending on the jacket colour

Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

Steel Wire Armoured Cables SWA

UX1ELWF

Page 39: Fiber Optic Cables 2018

39

Order information

Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1

UX1ELWF Ø 9,9 Fca

4 01.04.M3.B 01.04.M4.B 01.04.M5.B 01.04.S2.B 01.04.S7.B

6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B

8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B

12 01.12.M3.B 01.12.M4.B 01.12.M5.B 01.12.S2.B 01.12.S7.B

16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B

20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B

24 01.24.M3.B 01.24.M4.B 01.24.M5.B R848361 01.24.S7.B

Order code e.g.: UX1ELWF 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1 n.a. (long term) 4500 N (short term)

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

Crush EN 60794-1-21:E3A 2000 N/100mm (long term)4000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 20 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -20°C ÷ 70°C-30°C ÷ 70°C

Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible

Temperature range of use

-5°C ÷ 50°C-20°C ÷ 70°C-30°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage under inner sheath

* EN 60794-3-10, EN 60794-3-11

Fire performance

Flammability - cable bundle EN 60332-3-22 (cat.A) Pass

Smoke density EN 61034-1, EN 61034-2 Pass

Halogen Free, Acid gases EN 60754-2 Pass

Euro classification to CPR EN 50575, EN 13501-6 Fca

Cable expected lifetime / min. 30 years

Central Loose Tube Cables

Page 40: Fiber Optic Cables 2018

40

R&M generates added value. Connectivity that matters.Cable construction code DIN code

UX1EFWF xx.yy.zz.c J/A-DQ(ZN)HBH wbg (R 0,63vzk)

1. Gel filled PBT loose tube with optical fibers2. Water-blocking e-glass yarn3. FRLSZH UV stable inner jacket4. Zn galvanized steel wire armour fixed by PET tape5. Rip-cord6. FRLSZH UV stable outer jacket

Cable general description

Max. 24 fiber uni-tube steel wire armoured cable with two jackets for indoor or outdoor duct or direct buried installation. This cable construction offers excellent mechanical and full rodent protection.

Construction and dimensions

Loose tube nominal diameter 3,0 mm

Inner jacket nominal thickness 1,1 mm

Steel wire nominal diameter 0,63 mm

Outer jacket nominal thickness 1,3 mm

Cable nominal outer diameter 9,9 mm

Cable informative weight 180 kg/km

Standard put-up length 2100/4100 m ± 5%

Outer jacket

Material UV stable FRLSZH

Jacket colour Black. Other colours available on request

Sheath marking Ink-Jet, white or black depending on the jacket colour

Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

Steel Wire Armoured Cables SWA

UX1EFWF

Page 41: Fiber Optic Cables 2018

41

Order information

Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1

UX1EFWF Ø 9,9 Dca-s2,d2,a1

4 01.04.M3.B 01.04.M4.B 01.04.M5.B 01.04.S2.B 01.04.S7.B

6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B

8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B

12 01.12.M3.B 01.12.M4.B 01.12.M5.B 01.12.S2.B 01.12.S7.B

16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B

20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B

24 01.24.M3.B 01.24.M4.B 01.24.M5.B R848362 01.24.S7.B

Order code e.g.: UX1EFWF 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1 n.a. (long term) 4500 N (short term)

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

Crush EN 60794-1-21:E3A 2000 N/100mm (long term)4000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 20 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -30°C ÷ 70°C-35°C ÷ 70°C

Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible

Temperature range of use

-5°C ÷ 50°C-30°C ÷ 70°C-35°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage under inner sheath

* EN 60794-3-10, EN 60794-3-11

Fire performance

Flammability - cable bundle EN 60332-3-22 (cat.A) Pass

Smoke density EN 61034-1, EN 61034-2 Pass

Halogen Free, Acid gases EN 60754-2 Pass

Euro classification to CPR EN 50575, EN 13501-6 Dca-s2,d2,a1

Cable expected lifetime / min. 30 years

Central Loose Tube Cables

Page 42: Fiber Optic Cables 2018

42

R&M generates added value. Connectivity that matters.Cable construction code DIN code

OX1ECH xx.yy.zz.c A-DQ(ZN)(SR)2Y wbg

1. Gel filled PBT loose tube with optical fibers2. Water-blocking e-glass yarn3. Rip-cord4. Corrugated steel tape armour5. HDPE UV stable outer jacket

Cable general description

Max. 24 fiber uni-tube steel wire armoured cable with two jackets for outdoor duct or direct buried installation. This cable construction offers excellent mechanical and full rodent protection.

Construction and dimensions

Loose tube nominal diameter 3,0 mm

Inner jacket nominal thickness 1,2 mm

Cable nominal outer diameter 7,7 mm

Cable informative weight 70 kg/km

Standard put-up length 2100/4100 m ± 5%

Outer jacket

Material UV stable LDPE

Jacket colour Black

Sheath marking Ink-Jet, white

Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

Corrugated Steel Tape Armoured Cables CSTA

OX1ECH

Page 43: Fiber Optic Cables 2018

43

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1 500 N (long term)1500 N (short term)

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

Crush EN 60794-1-21:E3A 2500 N/100mm (long term)5000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 20 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -20°C ÷ 70°C-30°C ÷ 70°C

Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible

Temperature range of use

-5°C ÷ 50°C-20°C ÷ 70°C-30°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage

* EN 60794-3-10, EN 60794-3-11 Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1

OX1ECH Ø 7,7

4 01.04.M3.B 01.04.M4.B 01.04.M5.B 01.04.S2.B 01.04.S7.B

6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B

8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B

12 01.12.M3.B 01.12.M4.B 01.12.M5.B 01.12.S2.B 01.12.S7.B

16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B

20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B

24 01.24.M3.B 01.24.M4.B 01.24.M5.B R851112 01.24.S7.B

Order code e.g.: OX1ECH 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Central Loose Tube Cables

Page 44: Fiber Optic Cables 2018

44

R&M generates added value. Connectivity that matters.Cable construction code DIN code

UX1ECF xx.yy.zz.c J/A-DQ(ZN)(SR)H wbg

1. Gel filled PBT loose tube with optical fibers2. Water-blocking e-glass yarn3. Rip-cord4. Corrugated steel tape armour5. FRLSZH UV stable outer jacket

Cable general description

Max. 24 fiber uni-tube corrugated steel tape armoured cable for indoor or outdoor duct or direct buried installation. This cable construction offers good mechanical and full rodent protection.

Construction and dimensions

Loose tube nominal diameter 3,0 mm

Inner jacket nominal thickness 1,2 mm

Cable nominal outer diameter 7,7 mm

Cable informative weight 84 kg/km

Standard put-up length 2100/4100 m ± 5%

Outer jacket

Material UV stable FRLSZH

Jacket colour Black. Other colours available on request

Sheath marking Ink-Jet, white or black depending on the jacket colour

Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

Corrugated Steel Tape Armoured Cables CSTA

UX1ECF

Page 45: Fiber Optic Cables 2018

45

Order information

Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1

UX1ECF Ø 7,7 Dca-s2,d2,a1

4 01.04.M3.B 01.04.M4.B 01.04.M5.B 01.04.S2.B 01.04.S7.B

6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B

8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B

12 01.12.M3.B 01.12.M4.B 01.12.M5.B 01.12.S2.B 01.12.S7.B

16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B

20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B

24 01.24.M3.B 01.24.M4.B 01.24.M5.B R848363 01.24.S7.B

Order code e.g.: UX1ECF 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1 500 N (long term)1500 N (short term)

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

Crush EN 60794-1-21:E3A 2500 N/100mm (long term)5000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 20 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -30°C ÷ 70°C-35°C ÷ 70°C

Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible

Temperature range of use

-5°C ÷ 50°C-30°C ÷ 70°C-35°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage

* EN 60794-3-10, EN 60794-3-11

Fire performance

Flammability - cable bundle EN 60332-3-22 (cat.A) Pass

Smoke density EN 61034-1, EN 61034-2 Pass

Halogen Free, Acid gases EN 60754-2 Pass

Euro classification to CPR EN 50575, EN 13501-6 Dca-s2,d2,a1

Cable expected lifetime / min. 30 years

Central Loose Tube Cables

Page 46: Fiber Optic Cables 2018

46

R&M generates added value. Connectivity that matters.Cable construction code DIN code

OX1ELCH xx.yy.zz.c A-DQ(ZN)2Y(SR)2Y wbg

1. Gel filled PBT loose tube with optical fibers2. Water-blocking e-glass yarn3. LDPE UV stable inner jacket4. Rip-cord5. Corrugated steel tape armour6. HDPE UV stable outer jacket

Cable general description

Max. 24 fiber uni-tube corrugated steel tape armoured cable with two jackets for outdoor duct or direct buriedinstallation. This cable construction offers excellent mechanical and full rodent protection.

Construction and dimensions

Loose tube nominal diameter 3,1 mm

Inner jacket nominal thickness 0,8 mm

Outer jacket nominal thickness 1,2 mm

Cable nominal outer diameter 10,0 mm

Cable informative weight 100 kg/km

Standard put-up length 2100/4100 m ± 5%

Outer jacket

Material UV stable LDPE

Jacket colour Black

Sheath marking Ink-Jet, white

Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

Corrugated Steel Tape Armoured Cables CSTA

OX1ELCH

Page 47: Fiber Optic Cables 2018

47

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1 500 N (long term)1500 N (short term)

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

Crush EN 60794-1-21:E3A 2500 N/100mm (long term)5000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 20 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -20°C ÷ 70°C-25°C ÷ 70°C

Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible

Temperature range of use

-5°C ÷ 50°C-20°C ÷ 70°C-25°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage under inner sheath

* EN 60794-3-10, EN 60794-3-11 Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1

OX1ELCH Ø 10,0

4 01.04.M3.B 01.04.M4.B 01.04.M5.B 01.04.S2.B 01.04.S7.B

6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B

8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B

12 01.12.M3.B 01.12.M4.B 01.12.M5.B 01.12.S2.B 01.12.S7.B

16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B

20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B

24 01.24.M3.B 01.24.M4.B 01.24.M5.B R848364 01.24.S7.B

Order code e.g.: OX1ELCH 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Central Loose Tube Cables

Page 48: Fiber Optic Cables 2018

48

R&M generates added value. Connectivity that matters.Cable construction code DIN code

UX1ELCF xx.yy.zz.c J/A-DQ(ZN)2Y(SR)H wbg

1. Gel filled PBT loose tube with optical fibers2. Water-blocking e-glass yarn3. LDPE UV stable inner jacket4. Rip-cord5. Corrugated steel tape armour6. FRLSZH UV stable outer jacket

Cable general description

Max. 24 fiber uni-tube corrugated steel tape armoured cable with two jackets for indoor or outdoor duct or direct buried installation. This cable construction offers excellent mechanical and full rodent protection.

Construction and dimensions

Loose tube nominal diameter 3,0 mm

Inner jacket nominal thickness 0,8 mm

Outer jacket nominal thickness 1,2 mm

Cable nominal outer diameter 10,0 mm

Cable informative weight 115 kg/km

Standard put-up length 2100/4100 m ± 5%

Outer jacket

Material UV stable FRLSZH

Jacket colour Black. Other colours available on request

Sheath marking Ink-Jet, white or black depending on the jacket colour

Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

Corrugated Steel Tape Armoured Cables CSTA

UX1ELCF

Page 49: Fiber Optic Cables 2018

49

Order information

Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1

UX1ELCF Ø 10,0 Fca

4 01.04.M3.B 01.04.M4.B 01.04.M5.B 01.04.S2.B 01.04.S7.B

6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B

8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B

12 01.12.M3.B 01.12.M4.B 01.12.M5.B 01.12.S2.B 01.12.S7.B

16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B

20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B

24 01.24.M3.B 01.24.M4.B 01.24.M5.B R848365 01.24.S7.B

Order code e.g.: UX1ELCF 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1 500 N (long term)1500 N (short term)

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

Crush EN 60794-1-21:E3A 2500 N/100mm (long term)5000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 20 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -20°C ÷ 70°C-30°C ÷ 70°C

Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible

Temperature range of use

-5°C ÷ 50°C-20°C ÷ 70°C-30°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage under inner sheath

* EN 60794-3-10, EN 60794-3-11

Fire performance

Flammability - cable bundle EN 60332-3-22 (cat.A) Pass

Smoke density EN 61034-1, EN 61034-2 Pass

Halogen Free, Acid gases EN 60754-2 Pass

Euro classification to CPR EN 50575, EN 13501-6 Fca

Cable expected lifetime / min. 30 years

Central Loose Tube Cables

Page 50: Fiber Optic Cables 2018

50

R&M generates added value. Connectivity that matters.Cable construction code DIN code

UX1EFCF xx.yy.zz.c J/A-DQ(ZN)H(SR)H wbg

1. Gel filled PBT loose tube with optical fibers2. Water-blocking e-glass yarn3. FRLSZH UV stable inner jacket4. Rip-cord5. Corrugated steel tape armour6. FRLSZH UV stable outer jacket

Cable general description

Max. 24 fiber uni-tube corrugated steel tape armoured cable with two jackets for indoor or outdoor duct or direct buried installation. This cable construction offers excellent mechanical and full rodent protection.

Construction and dimensions

Loose tube nominal diameter 3,0 mm

Inner jacket nominal thickness 0,8 mm

Outer jacket nominal thickness 1,2 mm

Cable nominal outer diameter 10,0 mm

Cable informative weight 125 kg/km

Standard put-up length 2100/4100 m ± 5%

Outer jacket

Material UV stable FRLSZH

Jacket colour Black. Other colours available on request

Sheath marking Ink-Jet, white or black depending on the jacket colour

Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

Corrugated Steel Tape Armoured Cables CSTA

UX1EFCF

Page 51: Fiber Optic Cables 2018

51

Order information

Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1

UX1EFCF Ø 10,0 Cca-s1,d0,a1

4 01.04.M3.B 01.04.M4.B 01.04.M5.B 01.04.S2.B 01.04.S7.B

6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B

8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B

12 01.12.M3.B 01.12.M4.B 01.12.M5.B 01.12.S2.B 01.12.S7.B

16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B

20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B

24 01.24.M3.B 01.24.M4.B 01.24.M5.B R849571 01.24.S7.B

Order code e.g.: UX1EFCF 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1 500 N (long term)1500 N (short term)

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

Crush EN 60794-1-21:E3A 2500 N/100mm (long term)5000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 20 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -30°C ÷ 70°C-35°C ÷ 70°C

Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible

Temperature range of use

-5°C ÷ 50°C-30°C ÷ 70°C-35°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage under inner sheath

* EN 60794-3-10, EN 60794-3-11

Fire performance

Flammability - cable bundle EN 60332-3-22 (cat.A) Pass

Smoke density EN 61034-1, EN 61034-2 Pass

Halogen Free, Acid gases EN 60754-2 Pass

Euro classification to CPR EN 50575, EN 13501-6 Cca-s1,d0,a1

Cable expected lifetime / min. 30 years

Central Loose Tube Cables

Page 52: Fiber Optic Cables 2018

52

R&M generates added value. Connectivity that matters.Cable construction code DIN code

OX1PH xx.yy.zz.c A-DQ(ZN)B2Y (FRP 1,0)

1. Gel filled PBT loose tube with optical fibers2. Water swellable yarn3. Armour of FRP rods fixed by PET tape4. Rip-cord5. HDPE UV stable outer jacket

Cable general description

Max. 24 fiber uni-tube corrugated steel tape armoured cable with two jackets for outdoor duct or direct buriedinstallation. This cable construction offers excellent mechanical and full rodent protection.

Construction and dimensions

Loose tube nominal diameter 3,0 mm

Outer jacket nominal thickness 1,2 mm

Cable nominal outer diameter 7,4 mm

Cable informative weight 52 kg/km

Standard put-up length 2100/4100 m ± 5%

Outer jacket

Material UV stable LDPE

Jacket colour Black

Sheath marking Ink-Jet, white

Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

Fiber Reinforced Plastic Rod Armoured Cables FRPA

OX1PH

Page 53: Fiber Optic Cables 2018

53

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1 800 N (long term) 2500 N (short term)

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

Crush EN 60794-1-21:E3A 1500 N/100mm (long term)3000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 20 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -20°C ÷ 70°C-30°C ÷ 70°C

Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible

Temperature range of use

-5°C ÷ 50°C-20°C ÷ 70°C-30°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage

* EN 60794-3-10, EN 60794-3-11 Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1

OX1PH Ø 7,4

4 01.04.M3.B 01.04.M4.B 01.04.M5.B 01.04.S2.B 01.04.S7.B

6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B

8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B

12 01.12.M3.B 01.12.M4.B 01.12.M5.B 01.12.S2.B 01.12.S7.B

16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B

20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B

24 01.24.M3.B 01.24.M4.B 01.24.M5.B R849572 01.24.S7.B

Order code e.g.: OX1PH 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Central Loose Tube Cables

Page 54: Fiber Optic Cables 2018

54

R&M generates added value. Connectivity that matters.Cable construction code DIN code

UX1PF xx.yy.zz.c J/A-DQ(ZN)BH (FRP 1,0)

1. Gel filled PBT loose tube with optical fibers2. Water swellable yarn3. Armour of FRP rods4. Rip-cord5. FRLSZH UV stable outer jacket

Cable general description

Max. 24 fiber uni-tube non-metallic FRP rods armoured cable for indoor or outdoor duct or direct buried installation. This cable construction offers good mechanical and full rodent protection.

Construction and dimensions

Loose tube nominal diameter 3,0 mm

Outer jacket nominal thickness 1,2 mm

Cable nominal outer diameter 7,4 mm

Cable informative weight 65 kg/km

Standard put-up length 2100/4100 m ± 5%

Outer jacket

Material UV stable FRLSZH

Jacket colour Black. Other colours available on request

Sheath marking Ink-Jet, white or black depending on the jacket colour

Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

Fiber Reinforced Plastic Rod Armoured Cables FRPA

UX1PF

Page 55: Fiber Optic Cables 2018

55

Order information

Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1

UX1PF Ø 7,4 Fca

4 01.04.M3.B 01.04.M4.B 01.04.M5.B 01.04.S2.B 01.04.S7.B

6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B

8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B

12 01.12.M3.B 01.12.M4.B 01.12.M5.B 01.12.S2.B 01.12.S7.B

16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B

20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B

24 01.24.M3.B 01.24.M4.B 01.24.M5.B R849573 01.24.S7.B

Order code e.g.: UX1PF 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1 800 N (long term) 2500 N (short term)

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

Crush EN 60794-1-21:E3A 1500 N/100mm (long term)3000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 20 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -30°C ÷ 70°C-35°C ÷ 70°C

Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible

Temperature range of use

-5°C ÷ 50°C-30°C ÷ 70°C-35°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage under inner sheath

* EN 60794-3-10, EN 60794-3-11

Fire performance

Flammability - cable bundle EN 60332-3-22 (cat.A) Pass

Smoke density EN 61034-1, EN 61034-2 Pass

Halogen Free, Acid gases EN 60754-2 Pass

Euro classification to CPR EN 50575, EN 13501-6 Fca

Cable expected lifetime / min. 30 years

Central Loose Tube Cables

Page 56: Fiber Optic Cables 2018

56

R&M generates added value. Connectivity that matters.Cable construction code DIN code

QT1GF xx.yy.zz.c J/A-DQ(BN)H wbg fr

1. Gel filled PBT loose tube with optical fibers2. Fire-resistant tape3. Water-blocking e-glass yarn4. FRLSZH UV stable outer jacket

Cable general description

Max. 12 fiber uni-tube non-metallic fire-resistant cable for indoor or outdoor duct installation. This cable construction offers improved rodent protection.

Construction and dimensions

Loose tube nominal diameter 2,3 mm

Outer jacket nominal thickness 1,3 mm

Cable nominal outer diameter 7,0 mm

Cable informative weight 58 kg/km

Standard put-up length 2100/4100 m ± 5%

Outer jacket

Material UV stable FRLSZH

Jacket colour Black. Other colours available on request

Sheath marking Ink-Jet, white or black depending on the jacket colour

Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

Fire Resistant Cables All-dielectric Non-armoured

QT1GF

Page 57: Fiber Optic Cables 2018

57

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1 800 N (long term) 2000 N (short term)

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

Crush EN 60794-1-21:E3A 1000 N/100mm (long term)2000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 10 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -30°C ÷ 70°C-35°C ÷ 70°C

Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible

Temperature range of use

-5°C ÷ 50°C-30°C ÷ 70°C -35°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage

* EN 60794-3-10, EN 60794-3-11

Fire performance

Fire resistance EN 60331-25 (180 min at 750°C) Pass

Flammability - cable bundle EN 60332-3-22 (cat.A) Pass

Smoke density EN 61034-1, EN 61034-2 Pass

Halogen Free, Acid gases EN 60754-2 Pass

Euro classification to CPR EN 50575, EN 13501-6 Dca-s1,d1,a1

Cable expected lifetime / min. 30 years

Central Loose Tube Cables

Order information

Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1

QT1GF Ø 7,0 Dca-s1,d1,a1

4 01.04.M3.B 01.04.M4.B 01.04.M5.B 01.04.S2.B 01.04.S7.B

6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B

8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B

12 01.12.M3.B 01.12.M4.B 01.12.M5.B R849574 01.12.S7.B

Order code e.g.: UT1EF 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Page 58: Fiber Optic Cables 2018

58

R&M generates added value. Connectivity that matters.Cable construction code DIN code

QX1GF xx.yy.zz.c J/A-DQ(BN)H wbg fr

1. Gel filled PBT loose tube with optical fibers2. Fire-resistant tape3. Water-blocking e-glass yarn4. FRLSZH UV stable outer jacket

Cable general description

Max. 24 fiber uni-tube non-metallic fire-resistant cable for indoor or outdoor duct installation. This cable construction offers improved rodent protection.

Construction and dimensions

Loose tube nominal diameter 3,0 mm

Outer jacket nominal thickness 1,3 mm

Cable nominal outer diameter 7,8 mm

Cable informative weight 68 kg/km

Standard put-up length 2100/4100 m ± 5%

Outer jacket

Material UV stable FRLSZH

Jacket colour Black. Other colours available on request

Sheath marking Ink-Jet, white or black depending on the jacket colour

Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

Fire Resistant Cables All-dielectric Non-armoured

QX1GF

Page 59: Fiber Optic Cables 2018

59

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1 800 N (long term) 2000 N (short term)

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

Crush EN 60794-1-21:E3A 1000 N/100mm (long term)2000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 10 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -30°C ÷ 70°C-35°C ÷ 70°C

Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible

Temperature range of use

-5°C ÷ 50°C-30°C ÷ 70°C-35°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage

* EN 60794-3-10, EN 60794-3-11

Fire performance

Fire resistance EN 60331-25 (180 min at 750°C) Pass

Flammability - cable bundle EN 60332-3-22 (cat.A) Pass

Smoke density EN 61034-1, EN 61034-2 Pass

Halogen Free, Acid gases EN 60754-2 Pass

Euro classification to CPR EN 50575, EN 13501-6 Dca-s2,d1,a1

Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1

QX1GF Ø 7,8 Dca-s2,d1,a1

16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B

20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B

24 01.24.M3.B 01.24.M4.B 01.24.M5.B R849575 01.24.S7.B

Order code e.g.: QX1GF 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Central Loose Tube Cables

Page 60: Fiber Optic Cables 2018

60

R&M generates added value. Connectivity that matters.Cable construction code DIN code

QX1ECF xx.yy.zz.c J/A-DQ(ZN)(SR)H wbg fr

1. Gel filled PBT loose tube with optical fibers2. Fire-resistant tape3. Water-blocking e-glass yarn4. Rip-cord5. Corrugated steel tape armour6. FRLSZH UV stable outer jacket

Cable general description

Max. 24 fiber uni-tube fire-resistant corrugated steel tape armoured cable for indoor or outdoor duct or direct buried installation. This cable construction offers good mechanical and full rodent protection.

Construction and dimensions

Loose tube nominal diameter 3,0 mm

Outer jacket nominal thickness 1,3 mm

Cable nominal outer diameter 8,0 mm

Cable informative weight 90 kg/km

Standard put-up length 2100/4100 m ± 5%

Outer jacket

Material UV stable FRLSZH

Jacket colour Black. Other colours available on request

Sheath marking Ink-Jet, white or black depending on the jacket colour

Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

Fire Resistant Cables Corrugated Steel Tape Armoured

QX1ECF

Page 61: Fiber Optic Cables 2018

61

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1 500 N (long term) 1500 N (short term)

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

Crush EN 60794-1-21:E3A 2500 N/100mm (long term)5000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 20 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -30°C ÷ 70°C-35°C ÷ 70°C

Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible

Temperature range of use

-5°C ÷ 50°C-30°C ÷ 70°C-35°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage

* EN 60794-3-10, EN 60794-3-11

Fire performance

Fire resistance EN 60331-25 (180 min at 750°C) Pass

Flammability - cable bundle EN 60332-3-22 (cat.A) Pass

Smoke density EN 61034-1, EN 61034-2 Pass

Halogen Free, Acid gases EN 60754-2 Pass

Euro classification to CPR EN 50575, EN 13501-6 Fca

Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1

QX1ECF Ø 8,0 Fca

4 01.04.M3.B 01.04.M4.B 01.04.M5.B 01.04.S2.B 01.04.S7.B

6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B

8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B

12 01.12.M3.B 01.12.M4.B 01.12.M5.B 01.12.S2.B 01.12.S7.B

16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B

20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B

24 01.24.M3.B 01.24.M4.B 01.24.M5.B R849576 01.24.S7.B

Order code e.g.: QX1ECF 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Central Loose Tube Cables

Page 62: Fiber Optic Cables 2018

62

R&M generates added value. Connectivity that matters.Cable construction code DIN code

QX1EFCF xx.yy.zz.c J/A-DQ(ZN)H(SR)H wbg fr

1. Gel filled PBT loose tube with optical fibers2. Fire-resistant tape3. Water-blocking e-glass yarn4. FRLSZH UV stable inner jacket5. Rip-cord6. Corrugated steel tape armour7. FRLSZH UV stable outer jacket

Cable general description

Max. 24 fiber uni-tube fire-resistant corrugated steel tape armoured cable with two jackets for indoor or outdoor duct or direct buried installation. This cable construction offers excellent mechanical and full rodent protection.

Construction and dimensions

Loose tube nominal diameter 3,0 mm

Inner jacket nominal thickness 1,0 mm

Outer jacket nominal thickness 1,2 mm

Cable nominal outer diameter 11,0 mm

Cable informative weight 150 kg/km

Standard put-up length 2100/4100 m ± 5%

Outer jacket

Material UV stable FRLSZH

Jacket colour Black. Other colours available on request

Sheath marking Ink-Jet, white or black depending on the jacket colour

Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

Fire Resistant Cables Corrugated Steel Tape Armoured

QX1EFCF

Page 63: Fiber Optic Cables 2018

63

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1 500 N (long term) 1500 N (short term)

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

Crush EN 60794-1-21:E3A 2500 N/100mm (long term)5000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 20 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -30°C ÷ 70°C-35°C ÷ 70°C

Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible

Temperature range of use

-5°C ÷ 50°C-30°C ÷ 70°C-35°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage under inner sheath

* EN 60794-3-10, EN 60794-3-11

Fire performance

Fire resistance EN 60331-25 (180 min at 750°C) Pass

Flammability - cable bundle EN 60332-3-22 (cat.A) Pass

Smoke density EN 61034-1, EN 61034-2 Pass

Halogen Free, Acid gases EN 60754-2 Pass

Euro classification to CPR EN 50575, EN 13501-6 Fca

Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1

QX1EFCF Ø 11,0 Fca

4 01.04.M3.B 01.04.M4.B 01.04.M5.B 01.04.S2.B 01.04.S7.B

6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B

8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B

12 01.12.M3.B 01.12.M4.B 01.12.M5.B 01.12.S2.B 01.12.S7.B

16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B

20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B

24 01.24.M3.B 01.24.M4.B 01.24.M5.B R849577 01.24.S7.B

Order code e.g.: QX1EFCF 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Central Loose Tube Cables

Page 64: Fiber Optic Cables 2018

64

R&M generates added value. Connectivity that matters.Cable construction code DIN code

QX1EFWF xx.yy.zz.c J/A-DQ(ZN)HBH wbg (R 0,63vzk) fr

1. Gel filled PBT loose tube with optical fibers2. Fire-resistant tape3. Water-blocking e-glass yarn4. FRLSZH UV stable inner jacket5. Zn galvanized steel wire armour fixed by PET tape6. Rip-cord7. FRLSZH UV stable outer jacket

Cable general description

Max. 24 fiber uni-tube fire-resistant steel wire armoured cable with two jackets for indoor or outdoor duct or direct buried installation. This cable construction offers excellent mechanical and full rodent protection.

Construction and dimensions

Loose tube nominal diameter 3,0 mm

Inner jacket nominal thickness 1,0 mm

Steel wire nominal diameter 0,63 mm

Outer jacket nominal thickness 1,3 mm

Cable nominal outer diameter 10,1 mm

Cable informative weight 185 kg/km

Standard put-up length 2100/4100 m ± 5%

Outer jacket

Material UV stable FRLSZH

Jacket colour Black. Other colours available on request

Sheath marking Ink-Jet, white or black depending on the jacket colour

Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

Fire Resistant Cables Steel Wire Armoured Cables

QX1EFWF

Page 65: Fiber Optic Cables 2018

65

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1 n.a. (long term) 4500 N (short term)

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

Crush EN 60794-1-21:E3A 2000 N/100mm (long term)4000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 20 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -30°C ÷ 70°C-35°C ÷ 70°C

Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible

Temperature range of use

-5°C ÷ 50°C-20°C ÷ 70°C-35°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage under inner sheath

* EN 60794-3-10, EN 60794-3-11

Fire performance

Fire resistance EN 60331-25 (180 min at 750°C) Pass

Flammability - cable bundle EN 60332-3-22 (cat.A) Pass

Smoke density EN 61034-1, EN 61034-2 Pass

Halogen Free, Acid gases EN 60754-2 Pass

Euro classification to CPR EN 50575, EN 13501-6 Fca

Circuit integrity maintenance of cable systems under fire conditions

ČSN 73 0895, DIN 4102-12 (< 0,3 dB/m*) P90-R

* ČSN EN 50582 - Procedure to assess the circuit integrity of optical fibers in a cable under resistance to fire testing determines the maximum increase in attenuation 1,0 dB/m

Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1

QX1EFWF Ø 10,1 Fca

4 01.04.M3.B 01.04.M4.B 01.04.M5.B 01.04.S2.B 01.04.S7.B

6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B

8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B

12 01.12.M3.B 01.12.M4.B 01.12.M5.B 01.12.S2.B 01.12.S7.B

16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B

20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B

24 01.24.M3.B 01.24.M4.B 01.24.M5.B R849578 01.24.S7.B

Order code e.g.: QX1EFWF 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Central Loose Tube Cables

Page 66: Fiber Optic Cables 2018

66

R&M generates added value. Connectivity that matters.Cable construction code DIN code

QX1ELWF xx.yy.zz.c J/A-DQ(ZN)2YBH wbg (R 0,63vzk) fr

1. Gel filled PBT loose tube with optical fibers2. Fire-resistant tape3. Water-blocking e-glass yarn4. LDPE UV stable inner jacket5. Zn galvanized steel wire armour fixed by PET tape6. Rip-cord7. FRLSZH UV stable outer jacket

Cable general description

Max. 24 fiber uni-tube fire-resistant steel wire armoured cable with two jackets for indoor or outdoor duct or direct buried installation. This cable construction offers excellent mechanical and full rodent protection.

Construction and dimensions

Loose tube nominal diameter 3,1 mm

Inner jacket nominal thickness 1,0 mm

Steel wire nominal diameter 0,63 mm

Outer jacket nominal thickness 1,3 mm

Cable nominal outer diameter 10,1 mm

Cable informative weight 185 kg/km

Standard put-up length 2100/4100 m ± 5%

Outer jacket

Material UV stable FRLSZH

Jacket colour Black. Other colours available on request

Sheath marking Ink-Jet, white or black depending on the jacket colour

Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

Fire Resistant Cables Steel Wire Armoured Cables

QX1ELWF

Page 67: Fiber Optic Cables 2018

67

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1 n.a. (long term) 4500 N (short term)

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

Crush EN 60794-1-21:E3A 2000 N/100mm (long term)4000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 20 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -20°C ÷ 70°C-25°C ÷ 70°C

Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible

Temperature range of use

-5°C ÷ 50°C-20°C ÷ 70°C-25°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage under inner sheath

* EN 60794-3-10, EN 60794-3-11

Fire performance

Fire resistance EN 60331-25 (180 min at 750°C) Pass

Flammability - cable bundle EN 60332-3-22 (cat.A) Pass

Smoke density EN 61034-1, EN 61034-2 Pass

Halogen Free, Acid gases EN 60754-2 Pass

Euro classification to CPR EN 50575, EN 13501-6 Fca

Cable expected lifetime / min. 30 years

Central Loose Tube Cables

Order information

Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1

QX1ELWF Ø 10,1 Fca

4 01.04.M3.B 01.04.M4.B 01.04.M5.B 01.04.S2.B 01.04.S7.B

6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B

8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B

12 01.12.M3.B 01.12.M4.B 01.12.M5.B 01.12.S2.B 01.12.S7.B

16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B

20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B

24 01.24.M3.B 01.24.M4.B 01.24.M5.B R849579 01.24.S7.B

Order code e.g.: QX1ELWF 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Page 68: Fiber Optic Cables 2018

68

R&M generates added value. Connectivity that matters.Cable construction code DIN code

QX1EFWFc xx.yy.zz.c J/A-DQ(ZN)HBHx wbg (R 0,63vzk) fr

1. Gel filled PBT loose tube with optical fibers2. Fire-resistant tape3. Water-blocking e-glass yarn4. LDPE UV stable inner jacket5. Zn galvanized steel wire armour fixed by PET tape6. Rip-cord7. XL-FRLSZH UV stable outer jacket

Cable general description

Max. 24 fiber uni-tube fire-resistant steel wire armoured cable with two jackets for indoor or outdoor duct or direct buried installation. This cable construction offers excellent mechanical and full rodent protection.

Construction and dimensions

Loose tube nominal diameter 3,1 mm

Inner jacket nominal thickness 1,0 mm

Steel wire nominal diameter 0,63 mm

Outer jacket nominal thickness 1,3 mm

Cable nominal outer diameter 10,1 mm

Cable informative weight 185 kg/km

Standard put-up length 2100/4100 m ± 5%

Outer jacket

Material UV stable Cross-Linked FRLSZH

Jacket colour Black. Other colours available on request

Sheath marking Ink-Jet, white or black depending on the jacket colour

Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

Fire Resistant Cables Steel Wire Armoured Cables

QX1EFWFc

Page 69: Fiber Optic Cables 2018

69

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1 n.a. (long term) 4500 N (short term)

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

Crush EN 60794-1-21:E3A 2000 N/100mm (long term)4000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 20 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -30°C ÷ 70°C-35°C ÷ 70°C

Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible

Temperature range of use

-5°C ÷ 50°C-30°C ÷ 70°C-35°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage under inner sheath

* EN 60794-3-10, EN 60794-3-11

Fire performance

Fire resistance EN 60331-25 (180 min at 750°C) Pass

Flammability - cable bundle EN 60332-3-22 (cat.A) Pass

Smoke density EN 61034-1, EN 61034-2 Pass

Halogen Free, Acid gases EN 60754-2 Pass

Euro classification to CPR EN 50575, EN 13501-6 Fca

Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1

QX1EFWFc Ø 10,1 Fca

4 01.04.M3.B 01.04.M4.B 01.04.M5.B 01.04.S2.B 01.04.S7.B

6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B

8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B

12 01.12.M3.B 01.12.M4.B 01.12.M5.B 01.12.S2.B 01.12.S7.B

16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B

20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B

24 01.24.M3.B 01.24.M4.B 01.24.M5.B R851111 01.24.S7.B

Order code e.g.: QX1EFWFc 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Central Loose Tube Cables

Page 70: Fiber Optic Cables 2018

70

R&M generates added value. Connectivity that matters.Multi Loose Tube Cables. MLT.

Page 72: Fiber Optic Cables 2018

72

R&M generates added value. Connectivity that matters.

Multi Loose Tube Cables Overview

Microcables

MT6x1,5AH

76 MT.x1,5AH xx.yy.zz.c outdoor

72 fibers 6

1.55MT8x1,5AH 96 fibers 8

MT3x1,5AH 144 fibers 12

MT9x1,5AH 216 fibers 6 + 12 (18)

MT6x1,5AF

78 MT.x1,5AF xx.yy.zz.c indoor/outdoor

72 fibers 6

1.55MT8x1,5AF 96 fibers 8

MT3x1,5AF 144 fibers 12

MT3x1,5AHs 80 MT3x1,5AHs xx.yy.zz.c outdoor 144 fibers 12 1.55

All-dielectric Duct Cables

OT6x1,7H

82 OT.x1,7H xx.yy.zz.c outdoor

72 fibers 6

1.7 OT8x1,7H 96 fibers 8

OT3x1,7H 144 fibers 12

OT9x1,7H 216 fibers 6 + 12 (18)

UT6x1,7F

84 UT.x1,7F xx.yy.zz.c indoor/outdoor

72 fibers 6

1.7 UT8x1,7F 96 fibers 8

UT3x1,7F 144 fibers 12

UT9x1,7F 216 fibers 6 + 12 (18)

OT6x1,5AH

86 OT.x2,3EH xx.yy.zz.c outdoor

72 fibers 6

2.3 OT8x1,5AH 96 fibers 8

OT3x1,5AH 144 fibers 12

OT9x1,5AH 216 fibers 6 + 12 (18)

UT6x2,3EF

88 UT.x2,3EF xx.yy.zz.c indoor/outdoor

72 fibers 6

2.3 UT8x2,3EF 96 fibers 8

UT3x2,3EF 144 fibers 12

UT9x2,3EF 216 fibers 6 + 12 (18)

All-dielectric Duct Cables with improved rodent protection

OT6x1,7GH

90 OT.x1,7GH xx.yy.zz.c outdoor

72 fibers 6

1.7 OT8x1,7GH 96 fibers 8

OT3x1,7GH 144 fibers 12

OT9x1,7GH 216 fibers 6 + 12 (18)

UT6x1,7GF

92 UT.x1,7GF xx.yy.zz.c indoor/outdoor

72 fibers 6

1.7 UT8x1,7GF 96 fibers 8

UT3x1,7GF 144 fibers 12

UT9x1,7GF 216 fibers 6 + 12 (18)

OT6x2,3GH

94 OT.x2,3GH xx.yy.zz.c outdoor

72 fibers 6

2.3 OT8x2,3GH 96 fibers 8

OT3x2,3GH 144 fibers 12

OT9x2,3GH 216 fibers 6 + 12 (18)

UT6x2,3GF

96 UT.x2,3GF xx.yy.zz.c indoor/outdoor

72 fibers 6

2.3 UT8x2,3GF 96 fibers 8

UT3x2,3GF 144 fibers 12

UT9x2,3GF 216 fibers 6 + 12 (18)

Cable type Construction Page Construction code ApplicationFiber count[fibers]

Loose tubes count

Loose tube nominal Ø [mm]

Jacket material

Euro classification to CPR

Nominal cable Ø [mm]

Cable weight [kg/km]

Tensile performance [N]

Crush [N/100mm]

Temperatur range in operation

Fire resistance – EN 60331-25

Page 73: Fiber Optic Cables 2018

73

Microcables

MT6x1,5AH

76 MT.x1,5AH xx.yy.zz.c outdoor

72 fibers 6

1.55MT8x1,5AH 96 fibers 8

MT3x1,5AH 144 fibers 12

MT9x1,5AH 216 fibers 6 + 12 (18)

MT6x1,5AF

78 MT.x1,5AF xx.yy.zz.c indoor/outdoor

72 fibers 6

1.55MT8x1,5AF 96 fibers 8

MT3x1,5AF 144 fibers 12

MT3x1,5AHs 80 MT3x1,5AHs xx.yy.zz.c outdoor 144 fibers 12 1.55

All-dielectric Duct Cables

OT6x1,7H

82 OT.x1,7H xx.yy.zz.c outdoor

72 fibers 6

1.7 OT8x1,7H 96 fibers 8

OT3x1,7H 144 fibers 12

OT9x1,7H 216 fibers 6 + 12 (18)

UT6x1,7F

84 UT.x1,7F xx.yy.zz.c indoor/outdoor

72 fibers 6

1.7 UT8x1,7F 96 fibers 8

UT3x1,7F 144 fibers 12

UT9x1,7F 216 fibers 6 + 12 (18)

OT6x1,5AH

86 OT.x2,3EH xx.yy.zz.c outdoor

72 fibers 6

2.3 OT8x1,5AH 96 fibers 8

OT3x1,5AH 144 fibers 12

OT9x1,5AH 216 fibers 6 + 12 (18)

UT6x2,3EF

88 UT.x2,3EF xx.yy.zz.c indoor/outdoor

72 fibers 6

2.3 UT8x2,3EF 96 fibers 8

UT3x2,3EF 144 fibers 12

UT9x2,3EF 216 fibers 6 + 12 (18)

All-dielectric Duct Cables with improved rodent protection

OT6x1,7GH

90 OT.x1,7GH xx.yy.zz.c outdoor

72 fibers 6

1.7 OT8x1,7GH 96 fibers 8

OT3x1,7GH 144 fibers 12

OT9x1,7GH 216 fibers 6 + 12 (18)

UT6x1,7GF

92 UT.x1,7GF xx.yy.zz.c indoor/outdoor

72 fibers 6

1.7 UT8x1,7GF 96 fibers 8

UT3x1,7GF 144 fibers 12

UT9x1,7GF 216 fibers 6 + 12 (18)

OT6x2,3GH

94 OT.x2,3GH xx.yy.zz.c outdoor

72 fibers 6

2.3 OT8x2,3GH 96 fibers 8

OT3x2,3GH 144 fibers 12

OT9x2,3GH 216 fibers 6 + 12 (18)

UT6x2,3GF

96 UT.x2,3GF xx.yy.zz.c indoor/outdoor

72 fibers 6

2.3 UT8x2,3GF 96 fibers 8

UT3x2,3GF 144 fibers 12

UT9x2,3GF 216 fibers 6 + 12 (18)

HDPE

5.7 30.0 600

1'000 -40°C to 70°C

6.6 40.0 1'200

8.6 64.0 1'200

8.9 64.0 800

FRLSZH Fca

6.8 50.0 600

1'000 -40°C to 70°C

7.6 64.0 1'200

9.6 95.0 1'400

HDPE 7.6 44.0 400 500 -40°C to 70°C

HDPE

7.5 55.0

2'000 2'000 -40°C to 70°C

9.5 70.0

11.7 105.0

11.8 110.0

FRLSZH Eca

7.5 70.0

2'000 2'000 -40°C to 70°C

9.5 90.0

11.7 130.0

11.8 135.0

HDPE

10.0 80.0 2'000

2'000 -40°C to 70°C

11.4 110.0 2'700

14.2 170.0 3'000

14.6 170.0 3'000

FRLSZH Eca

10.0 100.0 2'000

2'000 -40°C to 70°C

11.4 130.0 2'700

14.2 190.0 3'000

14.6 195.0 3'000

HDPE

9.0 70.0 2'700

2'000 -40°C to 70°C

10.0 90.0 4'000

12.2 130.0 4'500

12.7 135.0 4'500

FRLSZH Eca

9.0 90.0 2'700

2'000 -40°C to 70°C

10.0 115.0 4'000

12.2 155.0 4'500

12.7 160.0 4'500

HDPE

11.0 100.0 3'500

2'000 -40°C to 70°C

12.5 130.0 4'000

15.3 190.0 5'000

15.7 195.0 5'000

FRLSZH Eca

11.0 120.0 3'500

2'000 -40°C to 70°C

12.5 150.0 4'000

15.3 220.0 5'000

15.7 230.0 5'000

Cable type Construction Page Construction code ApplicationFiber count[fibers]

Loose tubes count

Loose tube nominal Ø [mm]

Jacket material

Euro classification to CPR

Nominal cable Ø [mm]

Cable weight [kg/km]

Tensile performance [N]

Crush [N/100mm]

Temperatur range in operation

Fire resistance – EN 60331-25

Page 74: Fiber Optic Cables 2018

74

R&M generates added value. Connectivity that matters.

Steel Wire Armoured Cables – SWA

OT6x2,3LWH

98 OT.x2,3LWH xx.yy.zz.c outdoor

72 fibers 6

2.3 OT8x2,3LWH 96 fibers 8

OT3x2,3LWH 144 fibers 12

UT6x2,3FWF

100 UT.x2,3FWF xx.yy.zz.c indoor/outdoor

72 fibers 6

2.3 UT8x2,3FWF 96 fibers 8

UT3x2,3FWF 144 fibers 12

Corrugated Steel Tape Armoured Cables – CSTA

OT6x1,7ECH

102 OT.x1,7ECH xx.yy.zz.c outdoor

72 fibers 6

1.7 OT8x1,7ECH 96 fibers 8

OT3x1,7ECH 144 fibers 12

OT9x1,7ECH 216 fibers 6 + 12 (18)

UT6x1,7ECF

104 UT.x1,7ECF xx.yy.zz.c indoor/outdoor

72 fibers 6

1.7 UT8x1,7ECF 96 fibers 8

UT3x1,7ECF 144 fibers 12

UT9x1,7ECF 216 fibers 6 + 12 (18)

OT6x1,7ELCH

106 OT.x1,7ELCH xx.yy.zz.c outdoor

72 fibers 6

1.7 OT8x1,7ELCH 96 fibers 8

OT3x1,7ELCH 144 fibers 12

OT9x1,7ELCH 216 fibers 6 + 12 (18)

UT6x1,7EFCF

108 UT.x1,7EFCF xx.yy.zz.c indoor/outdoor

72 fibers 6

1.7UT8x1,7EFCF 96 fibers 8

UT3x1,7EFCF 144 fibers 12

UT9x1,7EFCF 216 fibers 6 + 12 (18)

Fire Resistant Cables – All-dielectric Non-armoured

QT6x2,3GF

110 QT.x2,3GF xx.yy.zz.c indoor/outdoor

72 fibers 6

2.3 QT8x2,3GF 96 fibers 8

QT3x2,3GF 144 fibers 12

Fire Resistant Cables – Corrugated Steel Tape Armoured

QT6x2,3EFCF

112 QT.x2,3EFCF xx.yy.zz.c indoor/outdoor

72 fibers 6

2.3 QT8x2,3EFCF 96 fibers 8

QT3x2,3EFCF 144 fibers 12

Fire Resistant Cables – Steel Wire Armoured Cables

QT6x2,3FWF

114 QT.x2,3FWF xx.yy.zz.c indoor/outdoor

72 fibers 6

2.3 QT8x2,3FWF 96 fibers 8

QT3x2,3FWF 144 fibers 12

Cable type Construction Page Construction code ApplicationFiber count[fibers]

Loose tubes count

Loose tube nominal Ø [mm]

Jacket material

Euro classification to CPR

Nominal cable Ø [mm]

Cable weight [kg/km]

Tensile performance [N]

Crush [N/100mm]

Temperatur range in operation

Fire resistance – EN 60331-25

Multi Loose Tube Cables Overview

Page 75: Fiber Optic Cables 2018

75

Steel Wire Armoured Cables – SWA

OT6x2,3LWH

98 OT.x2,3LWH xx.yy.zz.c outdoor

72 fibers 6

2.3 OT8x2,3LWH 96 fibers 8

OT3x2,3LWH 144 fibers 12

UT6x2,3FWF

100 UT.x2,3FWF xx.yy.zz.c indoor/outdoor

72 fibers 6

2.3 UT8x2,3FWF 96 fibers 8

UT3x2,3FWF 144 fibers 12

Corrugated Steel Tape Armoured Cables – CSTA

OT6x1,7ECH

102 OT.x1,7ECH xx.yy.zz.c outdoor

72 fibers 6

1.7 OT8x1,7ECH 96 fibers 8

OT3x1,7ECH 144 fibers 12

OT9x1,7ECH 216 fibers 6 + 12 (18)

UT6x1,7ECF

104 UT.x1,7ECF xx.yy.zz.c indoor/outdoor

72 fibers 6

1.7 UT8x1,7ECF 96 fibers 8

UT3x1,7ECF 144 fibers 12

UT9x1,7ECF 216 fibers 6 + 12 (18)

OT6x1,7ELCH

106 OT.x1,7ELCH xx.yy.zz.c outdoor

72 fibers 6

1.7 OT8x1,7ELCH 96 fibers 8

OT3x1,7ELCH 144 fibers 12

OT9x1,7ELCH 216 fibers 6 + 12 (18)

UT6x1,7EFCF

108 UT.x1,7EFCF xx.yy.zz.c indoor/outdoor

72 fibers 6

1.7UT8x1,7EFCF 96 fibers 8

UT3x1,7EFCF 144 fibers 12

UT9x1,7EFCF 216 fibers 6 + 12 (18)

Fire Resistant Cables – All-dielectric Non-armoured

QT6x2,3GF

110 QT.x2,3GF xx.yy.zz.c indoor/outdoor

72 fibers 6

2.3 QT8x2,3GF 96 fibers 8

QT3x2,3GF 144 fibers 12

Fire Resistant Cables – Corrugated Steel Tape Armoured

QT6x2,3EFCF

112 QT.x2,3EFCF xx.yy.zz.c indoor/outdoor

72 fibers 6

2.3 QT8x2,3EFCF 96 fibers 8

QT3x2,3EFCF 144 fibers 12

Fire Resistant Cables – Steel Wire Armoured Cables

QT6x2,3FWF

114 QT.x2,3FWF xx.yy.zz.c indoor/outdoor

72 fibers 6

2.3 QT8x2,3FWF 96 fibers 8

QT3x2,3FWF 144 fibers 12

HDPE

14.5 330.0 5'000

4'000 -40°C to 70°C 15.8 385.0 6'000

19.4 610.0 8'000

FRLSZH Fca

14.5 370.0 5'000

4'000 -40°C to 70°C 15.8 430.0 6'000

19.4 670.0 8'000

HDPE

11.0 115.0 2'500

5'000 -40°C to 70°C 12.0 140.0 4'000

14.0 185.0 4'000

14.0 185.0 3'500

FRLSZH Fca

11.0 135.0 2'500

5'000 -40°C to 70°C 12.0 165.0 4'000

14.0 210.0 4'000

14.0 210.0 3'500

HDPE

12.1 145.0 2'500

5'000 -40°C to 70°C 13.1 175.0 4'000

15.1 220.0 4'000

16.1 240.0 4'000

FRLSZH Fca

12.1 180.0 2'500

5'000 -40°C to 70°C 13.1 210.0 4'000

15.1 270.0 4'000

16.1 290.0 4'000

FRLSZH Fca

13.0 180.0 4'500

2'000 -40°C to 70°C 180 min at 750°C14.6 225.0 4'500

18.0 340.0 6'000

FRLSZH Fca

16.5 300.0 3'000

5'000 -40°C to 70°C 180 min at 750°C17.5 350.0 3'000

21.5 500.0 3'500

FRLSZH Fca

15.6 440.0 5'000

4'000 -40°C to 70°C 180 min at 750°C17.7 570.0 8'000

21.1 800.0 10'000

Cable type Construction Page Construction code ApplicationFiber count[fibers]

Loose tubes count

Loose tube nominal Ø [mm]

Jacket material

Euro classification to CPR

Nominal cable Ø [mm]

Cable weight [kg/km]

Tensile performance [N]

Crush [N/100mm]

Temperatur range in operation

Fire resistance – EN 60331-25

Page 76: Fiber Optic Cables 2018

76

R&M generates added value. Connectivity that matters.Cable construction code DIN code

MT.x1,5AH xx.yy.zz.c A-DQ(ZN)2Y nx1,5

1. FRP central strength member2. Water swellable yarn3. Gel filled PBT loose tube with optical fibers4. Water swellable aramid yarn5. Rip-cord6. HDPE UV stable outer jacket

Cable general description

Multi Loose Tube non-metallic micro-cable for outdoor installation to micro-tubes.

Construction and dimensions MT6x1,5AH MT8x1,5AH H MT3x1,5AH MT9x1,5AH

Max. fiber count (12 fibers/tube) 72 96 144 216

Loose-tubes count 6 8 12 18(6+12)-two layers

Loose tube nominal diameter (mm) 1,55 1,55 1,55 1,55

FRP/coat. CSM nominal thickness (mm) 1,7 2,5 2,5 / 4,5 1,7

Outer jacket nominal thickness (mm) 0,5 0,5 0,5 0,5

Cable nominal outer diameter (mm) 5,7 6,6 8,6 8,9

Cable informative weight (kg/km) 30 40 64 64

Standard put-up length (m) 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5%

Outer jacket

Material UV stable HDPE

Jacket colour Black

Sheath marking Ink-Jet, white

Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink

Loose-tube colour coding 1.red, 2.green (in each layer), rest of tubes white (fillers uncoloured or black)

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

MicrocablesMT.x1,5AH

Page 77: Fiber Optic Cables 2018

77

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1

MT6x.. MT8x.. MT3x.. MT9x..

Δα ≤ 0,05 dB after testshortterm

600 N

1200 N

1200 N

800N

Crush EN 60794-1-21:E3A 1000 N/100mm (short term) Δα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 5 Nm, 3 impacts, d = 20 mm, R = 300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R = 40 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Kink EN 60794-1-21:E10 d = 40 x cable diameter no damage

Bend no tension EN 60794-1-21:E11A R = 40 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -40°C ÷ 70°C Δα ≤ 0,05 dB

Temperature range of use

-5°C ÷ 50°C-40°C ÷ 70°C-40°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage

* EN 60794-5-10 Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count OM3 OM4 G652.D G657.A1

MT6x1,5AH Ø 5,7

4 x 8f 32f 04.08.M3.B 04.08.M4.B 04.08.S2.B 04.08.S7.B

4 x 12f 48f 04.12.M3.B 04.12.M4.B 04.12.S2.B 04.12.S7.B

6 x 6f 36f 06.06.M3.B 06.06.M4.B 06.06.S2.B 06.06.S7.B

6 x 8f 48f 06.08.M3.B 06.08.M4.B 06.08.S2.B 06.08.S7.B

6 x 12f 72f 06.12.M3.B 06.12.M4.B R851113 06.12.S7.B

MT8x1,5AH Ø 6,68 x 8f 64f 08.08.M3.B 08.08.M4.B 08.08.S2.B 08.08.S7.B

8 x 12f 96f 08.12.M3.B 08.12.M4.B 08.12.S2.B 08.12.S7.B

MT3x1,5AH Ø 8,612 x 8f 96f 12.08.M3.B 12.08.M4.B 12.08.S2.B 12.08.S7.B

12 x 12f 144f 12.12.M3.B 12.12.M4.B R851114 12.12.S7.B

MT9x1,5AH Ø 8,9

18 x 6f 108f 18.06.M3.B 18.06.M4.B 18.06.S2.B 18.06.S7.B

18 x 8f 144f 18.08.M3.B 18.08.M4.B 18.08.S2.B 18.08.S7.B

18 x 12f 216f 18.12.M3.B 18.12.M4.B 18.12.S2.B 18.12.S7.B

Order code e.g.: MT9x1,5AH 18.06.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Multi Loose Tube Cables

Page 78: Fiber Optic Cables 2018

78

R&M generates added value. Connectivity that matters.Cable construction code DIN code

MT.x1,5AF xx.yy.zz.c J/A-DQ(ZN)H nx1,5

1. FRP central strength member2. Water swellable yarn3. Gel filled PBT loose tube with optical fibers4. Water swellable aramid yarn5. Rip-cord6. FRLSZH UV stable outer jacket

Cable general description

Multi Loose Tube non-metallic micro-cable for indoor or outdoor installation to micro-tubes.

Construction and dimensions MT6x1,5AF MT8x1,5AF MT3x1,5AF

Max. fiber count (12 fibers/tube) 72 96 144

Loose-tubes count 6 8 12

Loose tube nominal diameter (mm) 1,55 1,55 1,55

FRP/coat. CSM nominal thickness (mm) 1,7 2,5 2,5 / 4,5

Outer jacket nominal thickness (mm) 1,0 1,0 1,0

Cable nominal outer diameter (mm) 6,8 7,6 9,6

Cable informative weight (kg/km) 50 64 95

Standard put-up length (m) 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5%

Outer jacket

Material UV stable FRLSZH

Jacket colour Black. Other colours available on request

Sheath marking Ink-Jet, white or black depending on the jacket colour

Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink

Loose-tube colour coding 1.red, 2.green, rest of tubes white (fillers uncoloured or black)

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

MicrocablesMT.x1,5AF

Page 79: Fiber Optic Cables 2018

79

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1

MT6x.. MT8x.. MT3x..

Δα ≤ 0,05 dB after testshortterm

600 N

1200 N

1400 N

Crush EN 60794-1-21:E3A 1000 N/100mm (short term) Δα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 5 Nm, 3 impacts, d = 20 mm, R = 300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R = 40 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Kink EN 60794-1-21:E10 d = 40 x cable diameter no damage

Bend no tension EN 60794-1-21:E11A R = 40 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -40°C ÷ 70°C Δα ≤ 0,05 dB

Temperature range of use

-5°C ÷ 50°C-40°C ÷ 70°C-40°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage

* EN 60794-5-10

Fire performance

Flammability - cable bundle EN 60332-3-22 (cat.A) Pass

Smoke density EN 61034-1, EN 61034-2 Pass

Halogen Free, Acid gases EN 50575, EN 13501-6 Pass

Euro classification to CPR Fca

Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count OM3 OM4 G652.D G657.A1

MT6x1,5AF Ø 6,8

4 x 8f 32f 04.08.M3.B 04.08.M4.B 04.08.S2.B 04.08.S7.B

4 x 12f 48f 04.12.M3.B 04.12.M4.B 04.12.S2.B 04.12.S7.B

6 x 6f 36f 06.06.M3.B 06.06.M4.B 06.06.S2.B 06.06.S7.B

6 x 8f 48f 06.08.M3.B 06.08.M4.B 06.08.S2.B 06.08.S7.B

6 x 12f 72f 06.12.M3.B 06.12.M4.B R851115 06.12.S7.B

MT8x1,5AF Ø 7,68 x 8f 64f 08.08.M3.B 08.08.M4.B 08.08.S2.B 08.08.S7.B

8 x 12f 96f 08.12.M3.B 08.12.M4.B 08.12.S2.B 08.12.S7.B

MT3x1,5AF Ø 9,612 x 8f 96f 12.08.M3.B 12.08.M4.B 12.08.S2.B 12.08.S7.B

12 x 12f 144f 12.12.M3.B 12.12.M4.B R851116 12.12.S7.B

Order code e.g.: MT3x1,5AF 12.08.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Multi Loose Tube Cables

Page 80: Fiber Optic Cables 2018

80

R&M generates added value. Connectivity that matters.Cable construction code DIN code

MT3x1,5AHs xx.yy.zz.c A-DQ(ZN)2Y 12x1,5

1. FRP central strength member2. Water swellable yarn3. Gel filled PBT loose tube with optical fibers4. Water swellable aramid yarn5. Rip-cord6. HDPE UV stable outer jacket

Cable general description

Multi Loose Tube non-metallic micro-cable for outdoor installation to micro-tubes. The cable contains max. 144 fibers in 12 loose-tubes SZ stranded in two layers.

Construction and dimensions

Loose tube nominal diameter 1,55 mm

Outer jacket nominal thickness 0,5 mm

Cable nominal outer diameter 7,6 mm

Cable informative weight 44 kg/km

Standard put-up length 2100/4100 m ± 5%

Outer jacket

Material UV stable HDPE

Jacket colour Black

Sheath marking Ink-Jet, white

Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink

Loose-tube colour coding 1.red, 2.green (in each layer), rest of tubes white (fillers uncoloured or black)

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

MicrocablesMT3x1,5AHs

Page 81: Fiber Optic Cables 2018

81

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1 400 N (short term) Δα ≤ 0,05 dB after test

Crush EN 60794-1-21:E3A 500 N/100mm (short term) Δα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 1 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=40 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Kink EN 60794-1-21:E10 d = 40 x cable diameter no damage

Bend no tension EN 60794-1-21:E11A R = 40 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -40°C ÷ 70°C Δα ≤ 0,05 dB

Temperature range of use

-5°C ÷ 50°C-40°C ÷ 70°C-40°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage

* EN 60794-5-10 Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count OM3 OM4 G652.D G657.A1

MT3x1,5AHs Ø 7,6

12 x 6f 72f 12.06.M3.B 12.06.M4.B 12.06.S2.B 12.06.S7.B

12 x 8f 96f 12.08.M3.B 12.08.M4.B 12.08.S2.B 12.08.S7.B

12 x 12f 144f 12.12.M3.B 12.12.M4.B R851117 12.12.S7.B

Order code e.g.: MT3x1,5AHs 12.06.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Multi Loose Tube Cables

Page 82: Fiber Optic Cables 2018

82

R&M generates added value. Connectivity that matters.Cable construction code DIN code

OT.x1,7H xx.yy.zz.c A-DQ(ZN)2Y nx1,7

1. FRP central strength member2. Water swellable yarn3. Gel filled PBT loose tube with optical fibers4. Water swellable tape or e-glass yarn5. Rip-cord6. HDPE UV stable outer jacket

Cable general description

Multi Loose Tube non-metallic cable for outdoor duct installation.

Construction and dimensions OT6x1,7H OT8x1,7H OT3x1,7H OT9x1,7H

Max. fiber count (12 fibers/tube) 72 96 144 216

Loose-tubes count 6 8 12 18(6+12)-two layers

Loose tube nominal diameter (mm) 1,7 1,7 1,7 1,7

FRP/coat. CSM nominal thickness (mm) 1,7 2,8 2,8 / 5,0 1,7

Outer jacket nominal thickness (mm) 1,2 1,2 1,2 1,2

Cable nominal outer diameter (mm) 7,5 9,5 11,7 11,8

Cable informative weight (kg/km) 55 70 105 110

Standard put-up length (m) 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5%

Outer jacket

Material UV stable HDPE

Jacket colour Black

Sheath marking Ink-Jet, white

Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink

Loose-tube colour coding 1.red, 2.green (in each layer), rest of tubes white (fillers uncoloured or black)

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

All-dielectric Duct Cables OT.x1,7H

Page 83: Fiber Optic Cables 2018

83

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1

OT6x.. OT8x.. OT3x.. OT9x..

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

longterm

800 N

800 N

800 N

800N

shortterm

2000 N

2000 N

2000 N

2000N

Crush EN 60794-1-21:E3A 1000 N/100mm (long term)2000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 10 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -40°C ÷ 70°C Δα ≤ 0,05 dB

Temperature range of use

-5°C ÷ 50°C-40°C ÷ 70°C-40°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage

* EN 60794-3-10, EN 60794-3-11 Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count OM3 OM4 G652.D G657.A1

OT6x1,7H Ø 7.5

4 x 8f 32f 04.08.M3.B 04.08.M4.B 04.08.S2.B 04.08.S7.B

4 x 12f 48f 04.12.M3.B 04.12.M4.B 04.12.S2.B 04.12.S7.B

6 x 6f 36f 06.06.M3.B 06.06.M4.B 06.06.S2.B 06.06.S7.B

6 x 8f 48f 06.08.M3.B 06.08.M4.B 06.08.S2.B 06.08.S7.B

6 x 12f 72f 06.12.M3.B 06.12.M4.B R851118 06.12.S7.B

OT8x1,7H Ø 9.5 8 x 8f 64f 08.08.M3.B 08.08.M4.B 08.08.S2.B 08.08.S7.B

8 x 12f 96f 08.12.M3.B 08.12.M4.B 08.12.S2.B 08.12.S7.B

OT3x1,7H Ø 11.7 12 x 8f 96f 12.08.M3.B 12.08.M4.B 12.08.S2.B 12.08.S7.B

12 x 12f 144f 12.12.M3.B 12.12.M4.B R851119 12.12.S7.B

OT9x1,7H Ø 11.8

18 x 6f 108f 18.06.M3.B 18.06.M4.B 18.06.S2.B 18.06.S7.B

18 x 8f 144f 18.08.M3.B 18.08.M4.B 18.08.S2.B 18.08.S7.B

18 x 12f 216f 18.12.M3.B 18.12.M4.B 18.12.S2.B 18.12.S7.B

Order code e.g.: OT6x1,7H 06.06.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Multi Loose Tube Cables

Page 84: Fiber Optic Cables 2018

84

R&M generates added value. Connectivity that matters.Cable construction code DIN code

UT.x1,7F xx.yy.zz.c J/A-DQ(ZN)H nx1,7

1. FRP central strength member2. Water swellable yarn3. Gel filled PBT loose tube with optical fibers4. Water swellable tape or yarn5. Rip-cord6. FRLSZH UV stable outer jacket

Cable general description

Multi Loose Tube non-metallic cable for indoor or outdoor duct installation.

Construction and dimensions UT6x1,7F UT8x1,7F UT3x1,7F UT9x1,7F

Max. fiber count (12 fibers/tube) 72 96 144 216

Loose-tubes count 6 8 12 18(6+12)-two layers

Loose tube nominal diameter (mm) 1,7 1,7 1,7 1,7

FRP/coat. CSM nominal thickness (mm) 1,7 2,8 2,8 / 5,0 1,7

Outer jacket nominal thickness (mm) 1,2 1,2 1,2 1,2

Cable nominal outer diameter (mm) 7,5 9,5 11,7 11,8

Cable informative weight (kg/km) 70 90 130 135

Standard put-up length (m) 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5%

Outer jacket

Material UV stable FRLSZH

Jacket colour Black. Other colours available on request

Sheath marking Ink-Jet, white or black depending on the jacket colour

Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink

Loose-tube colour coding 1.red, 2.green (in each layer), rest of tubes white (fillers uncoloured or black)

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

All-dielectric Duct Cables UT.x1,7F

Page 85: Fiber Optic Cables 2018

85

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1

UT6x.. UT8x.. UT3x.. UT9x..

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

longterm

800 N

800 N

800 N

800N

shortterm

2000 N

2000 N

2000 N

2000N

Crush EN 60794-1-21:E3A 1000 N/100mm (long term)2000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 10 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -40°C ÷ 70°C Δα ≤ 0,05 dB

Temperature range of use

-5°C ÷ 50°C-40°C ÷ 70°C-40°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage

* EN 60794-3-10, EN 60794-3-11

Fire performance

Flammability - cable bundle EN 60332-3-22 (cat.A) Pass

Smoke density EN 61034-1, EN 61034-2 Pass

Halogen Free, Acid gases EN 60754-2 Pass

Euro classification to CPR EN 50575, EN 13501-6 Eca

Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count OM3 OM4 G652.D G657.A1

UT6x1,7F Ø 7.5 Eca

4 x 8f 24f 04.08.M3.B 04.08.M4.B 04.08.S2.B 04.08.S7.B

4 x 12f 48f 04.12.M3.B 04.12.M4.B 04.12.S2.B 04.12.S7.B

6 x 6f 72f 06.06.M3.B 06.06.M4.B 06.06.S2.B 06.06.S7.B

6 x 8f 48f 06.08.M3.B 06.08.M4.B 06.08.S2.B 06.08.S7.B

6 x 12f 64f 06.12.M3.B 06.12.M4.B R851120 06.12.S7.B

UT8x1,7F Ø 9.5 Eca 8 x 8f 96f 08.08.M3.B 08.08.M4.B 08.08.S2.B 08.08.S7.B

8 x 12f 72f 08.12.M3.B 08.12.M4.B 08.12.S2.B 08.12.S7.B

UT3x1,7F Ø 11.7 Eca 12 x 8f 96f 12.08.M3.B 12.08.M4.B 12.08.S2.B 12.08.S7.B

12 x 12f 144f 12.12.M3.B 12.12.M4.B R851121 12.12.S7.B

UT9x1,7F Ø 11.8 Eca

18 x 6f 108f 18.06.M3.B 18.06.M4.B 18.06.S2.B 18.06.S7.B

18 x 8f 144f 18.08.M3.B 18.08.M4.B 18.08.S2.B 18.08.S7.B

18 x 12f 216f 18.12.M3.B 18.12.M4.B 18.12.S2.B 18.12.S7.B

Order code e.g.: UT6x1,7F 06.06.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Multi Loose Tube Cables

Page 86: Fiber Optic Cables 2018

86

R&M generates added value. Connectivity that matters.Cable construction code DIN code

OT.x2,3EH xx.yy.zz.c A-DQ(ZN)2Y wbg nx2,3

1. FRP central strength member2. Water swellable yarn3. Gel filled PBT loose tube with optical fibers4. Water swellable e-glass yarn5. Rip-cord6. HDPE UV stable outer jacket

Cable general description

Multi Loose Tube non-metallic cable with standard rodent protection for outdoor duct installation.

Construction and dimensions OT6x2,3EH OT8x2,3EH OT3x2,3EH OT9x2,3EH

Max. fiber count (12 fibers/tube) 72 96 144 216

Loose-tubes count 6 8 12 18(6+12)-two layers

Loose tube nominal diameter (mm) 2,3 2,3 2,3 2,3

FRP/coat. CSM nominal thickness (mm) 2,5 2,5 / 3,9 2,8 / 6,7 2,5

Outer jacket nominal thickness (mm) 1,2 1,2 1,2 1,2

Cable nominal outer diameter (mm) 10,0 11,4 14,2 14,6

Cable informative weight (kg/km) 80 110 170 170

Standard put-up length (m) 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5%

Outer jacket

Material UV stable HDPE

Jacket colour Black

Sheath marking Ink-Jet, white

Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink

Loose-tube colour coding 1.red, 2.green (in each layer), rest of tubes white (fillers uncoloured or black)

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

All-dielectric Duct Cables OT.x2,3EH

Page 87: Fiber Optic Cables 2018

87

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1

OT6x.. OT8x.. OT3x.. OT9x..

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

longterm

800 N

900 N

1000 N

1000N

shortterm

2000 N

2700 N

3000 N

3000N

Crush EN 60794-1-21:E3A 1000 N/100mm (long term)2000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 10 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -40°C ÷ 70°C Δα ≤ 0,05 dB

Temperature range of use

-5°C ÷ 50°C-40°C ÷ 70°C-40°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage

* EN 60794-3-10, EN 60794-3-11 Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count OM3 OM4 G652.D G657.A1

OT6x2,3EH Ø 10

4 x 8f 32f 04.08.M3.B 04.08.M4.B 04.08.S2.B 04.08.S7.B

4 x 12f 48f 04.12.M3.B 04.12.M4.B 04.12.S2.B 04.12.S7.B

6 x 6f 36f 06.06.M3.B 06.06.M4.B 06.06.S2.B 06.06.S7.B

6 x 8f 48f 06.08.M3.B 06.08.M4.B 06.08.S2.B 06.08.S7.B

6 x 12f 72f 06.12.M3.B 06.12.M4.B R851122 06.12.S7.B

OT8x2,3EH Ø 11.4 8 x 8f 64f 08.08.M3.B 08.08.M4.B 08.08.S2.B 08.08.S7.B

8 x 12f 96f 08.12.M3.B 08.12.M4.B 08.12.S2.B 08.12.S7.B

OT3x2,3EH Ø 14.2 12 x 8f 96f 12.08.M3.B 12.08.M4.B 12.08.S2.B 12.08.S7.B

12 x 12f 144f 12.12.M3.B 12.12.M4.B R851123 12.12.S7.B

OT9x2,3EH Ø 14.6

18 x 6f 108f 18.06.M3.B 18.06.M4.B 18.06.S2.B 18.06.S7.B

18 x 8f 144f 18.08.M3.B 18.08.M4.B 18.08.S2.B 18.08.S7.B

18 x 12f 216f 18.12.M3.B 18.12.M4.B 18.12.S2.B 18.12.S7.B

Order code e.g.: OT6x2,3EH 06.06.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Multi Loose Tube Cables

Page 88: Fiber Optic Cables 2018

88

R&M generates added value. Connectivity that matters.Cable construction code DIN code

UT.x2,3EF xx.yy.zz.c J/A-DQ(ZN)H wbg nx2,3

1. FRP central strength member2. Water swellable yarn3. Gel filled PBT loose tube with optical fibers4. Water swellable e-glass yarn5. Rip-cord6. FRLSZH UV stable outer jacket

Cable general description

Multi Loose Tube non-metallic cable with standard rodent protection for indoor or outdoor duct installation.

Construction and dimensions UT6x2,3EF UT8x2,3EF UT3x2,3EF UT9x2,3EF

Max. fiber count (12 fibers/tube) 72 96 144 216

Loose-tubes count 6 8 12 18(6+12)-two layers

Loose tube nominal diameter (mm) 2,3 2,3 2,3 2,3

FRP/coat. CSM nominal thickness (mm) 2,5 2,5 / 3,9 2,8 / 6,7 2,5

Outer jacket nominal thickness (mm) 1,2 1,2 1,2 1,2

Cable nominal outer diameter (mm) 10,0 11,4 14,2 14,6

Cable informative weight (kg/km) 100 130 190 195

Standard put-up length (m) 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5%

Outer jacket

Material UV stable FRLSZH

Jacket colour Black. Other colours available on request

Sheath marking Ink-Jet, white or black depending on the jacket colour

Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink

Loose-tube colour coding 1.red, 2.green (in each layer), rest of tubes white (fillers uncoloured or black)

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

All-dielectric Duct Cables UT.x2,3EF

Page 89: Fiber Optic Cables 2018

89

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1

UT6x.. UT8x.. UT3x.. UT9x..

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

longterm

800 N

900 N

1000 N

1000N

shortterm

2000 N

2700 N

3000 N

3000N

Crush EN 60794-1-21:E3A 1000 N/100mm (long term)2000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 10 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -40°C ÷ 70°C Δα ≤ 0,05 dB

Temperature range of use

-5°C ÷ 50°C-40°C ÷ 70°C-40°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage

* EN 60794-3-10, EN 60794-3-11

Fire performance

Flammability - cable bundle EN 60332-3-22 (cat.A) Pass

Smoke density EN 61034-1, EN 61034-2 Pass

Halogen Free, Acid gases EN 60754-2 Pass

Euro classification to CPR EN 50575, EN 13501-6 Eca

Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count OM3 OM4 G652.D G657.A1

UT6x2,3EF Ø 11,0 Eca

4 x 8f 32f 04.08.M3.B 04.08.M4.B 04.08.S2.B 04.08.S7.B

4 x 12f 48f 04.12.M3.B 04.12.M4.B 04.12.S2.B 04.12.S7.B

6 x 6f 36f 06.06.M3.B 06.06.M4.B 06.06.S2.B 06.06.S7.B

6 x 8f 48f 06.08.M3.B 06.08.M4.B 06.08.S2.B 06.08.S7.B

6 x 12f 72f 06.12.M3.B 06.12.M4.B R851124 06.12.S7.B

UT8x2,3EF Ø 12,5 Eca 8 x 8f 64f 08.08.M3.B 08.08.M4.B 08.08.S2.B 08.08.S7.B

8 x 12f 96f 08.12.M3.B 08.12.M4.B 08.12.S2.B 08.12.S7.B

UT3x2,3EF Ø 15,3 Eca 12 x 8f 96f 12.08.M3.B 12.08.M4.B 12.08.S2.B 12.08.S7.B

12 x 12f 144f 12.12.M3.B 12.12.M4.B R851125 12.12.S7.B

UT9x2,3EF Ø 15,7 Eca

18 x 6f 108f 18.06.M3.B 18.06.M4.B 18.06.S2.B 18.06.S7.B

18 x 8f 144f 18.08.M3.B 18.08.M4.B 18.08.S2.B 18.08.S7.B

18 x 12f 216f 18.12.M3.B 18.12.M4.B 18.12.S2.B 18.12.S7.B

Order code e.g.: UT6x2,3EF 06.06.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Multi Loose Tube Cables

Page 90: Fiber Optic Cables 2018

90

R&M generates added value. Connectivity that matters.Cable construction code DIN code

OT.x1,7GH xx.yy.zz.c A-DQ(BN)2Y wbg nx1,7

1. FRP central strength member2. Water swellable yarn3. Gel filled PBT loose tube with optical fibers4. Water swellable tape or e-glass yarn5. Rip-cord6. HDPE UV stable outer jacket

Cable general description

Multi Loose Tube non-metallic cable with improved rodent protection for outdoor duct installation.

Construction and dimensions OT6x1,7GH OT8x1,7GH OT3x1,7GH OT9x1,7GH

Max. fiber count (12 fibers/tube) 72 96 144 216

Loose-tubes count 6 8 12 18(6+12)-two layers

Loose tube nominal diameter (mm) 1,7 1,7 1,7 1,7

FRP/coat. CSM nominal thickness (mm) 1,7 2,8 2,5 / 5,0 1,7

Outer jacket nominal thickness (mm) 1,4 1,4 1,4 1,4

Cable nominal outer diameter (mm) 9,0 10,0 12,2 12,7

Cable informative weight (kg/km) 70 90 130 135

Standard put-up length (m) 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5%

Outer jacket

Material UV stable HDPE

Jacket colour Black

Sheath marking Ink-Jet, white

Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink

Loose-tube colour coding 1.red, 2.green (in each layer), rest of tubes white (fillers uncoloured or black)

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

All-dielectric Duct Cables with improved rodent protection

OT.x1,7GH

Page 91: Fiber Optic Cables 2018

91

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1

OT6x.. OT8x.. OT3x.. OT9x..

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

longterm

900 N

1200 N

1400 N

1400N

shortterm

2700 N

4000 N

4500 N

4500N

Crush EN 60794-1-21:E3A 1000 N/100mm (long term)2000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 10 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -40°C ÷ 70°C Δα ≤ 0,05 dB

Temperature range of use

-5°C ÷ 50°C-40°C ÷ 70°C-40°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage

* EN 60794-3-10, EN 60794-3-11 Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count OM3 OM4 G652.D G657.A1

OT6x1,7GH Ø 9,0

4 x 8f 32f 04.08.M3.B 04.08.M4.B 04.08.S2.B 04.08.S7.B

4 x 12f 48f 04.12.M3.B 04.12.M4.B 04.12.S2.B 04.12.S7.B

6 x 6f 36f 06.06.M3.B 06.06.M4.B 06.06.S2.B 06.06.S7.B

6 x 8f 48f 06.08.M3.B 06.08.M4.B 06.08.S2.B 06.08.S7.B

6 x 12f 72f 06.12.M3.B 06.12.M4.B 06.12.S2.B 06.12.S7.B

OT8x1,7GH Ø 10,0 8 x 8f 64f 08.08.M3.B 08.08.M4.B 08.08.S2.B 08.08.S7.B

8 x 12f 96f 08.12.M3.B 08.12.M4.B 08.12.S2.B 08.12.S7.B

OT3x1,7GH Ø 12,2 12 x 8f 96f 12.08.M3.B 12.08.M4.B 12.08.S2.B 12.08.S7.B

12 x 12f 144f 12.12.M3.B 12.12.M4.B R851126 12.12.S7.B

OT9x1,7GH Ø 12,7

18 x 6f 108f 18.06.M3.B 18.06.M4.B 18.06.S2.B 18.06.S7.B

18 x 8f 144f 18.08.M3.B 18.08.M4.B 18.08.S2.B 18.08.S7.B

18 x 12f 216f 18.12.M3.B 18.12.M4.B 18.12.S2.B 18.12.S7.B

Order code e.g.: OT6x1,7GH 06.06.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Multi Loose Tube Cables

Page 92: Fiber Optic Cables 2018

92

R&M generates added value. Connectivity that matters.Cable construction code DIN code

UT.x1,7GF xx.yy.zz.c J/A-DQ(BN)H wbg nx1,7

1. FRP central strength member2. Water swellable yarn3. Gel filled PBT loose tube with optical fibers4. Water swellable e-glass yarn5. Rip-cord6. FRLSZH UV stable outer jacket

Cable general description

Multi Loose Tube non-metallic cable with improved rodent protection for indoor or outdoor duct installation.

Construction and dimensions OT6x1,7GF OT8x1,7GF OT3x1,7GF OT9x1,7GF

Max. fiber count (12 fibers/tube) 72 96 144 216

Loose-tubes count 6 8 12 18(6+12)-two layers

Loose tube nominal diameter (mm) 1,7 1,7 1,7 1,7

FRP/coat. CSM nominal thickness (mm) 1,7 2,8 2,5 / 5,0 1,7

Outer jacket nominal thickness (mm) 1,4 1,4 1,4 1,4

Cable nominal outer diameter (mm) 9,0 10,0 12,2 12,7

Cable informative weight (kg/km) 90 115 155 160

Standard put-up length (m) 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5%

Outer jacket

Material UV stable FRLSZH

Jacket colour Black. Other colours available on request

Sheath marking Ink-Jet, white or black depending on the jacket colour

Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink

Loose-tube colour coding 1.red, 2.green (in each layer), rest of tubes white (fillers uncoloured or black)

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

All-dielectric Duct Cables with improved rodent protection

UT.x1,7GF

Page 93: Fiber Optic Cables 2018

93

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1

UT6x.. UT8x.. UT3x.. UT9x..

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

longterm

900 N

1200 N

1400 N

1400N

shortterm

2700 N

4000 N

4500 N

4500N

Crush EN 60794-1-21:E3A 1000 N/100mm (long term)2000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 10 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -40°C ÷ 70°C Δα ≤ 0,05 dB

Temperature range of use

-5°C ÷ 50°C-40°C ÷ 70°C-40°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage

* EN 60794-3-10, EN 60794-3-11

Fire performance

Flammability - cable bundle EN 60332-3-22 (cat.A) Pass

Smoke density EN 61034-1, EN 61034-2 Pass

Halogen Free, Acid gases EN 60754-2 Pass

Euro classification to CPR EN 50575, EN 13501-6 Eca

Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count OM3 OM4 G652.D G657.A1

UT6x1,7GF Ø 9,0 Eca

4 x 8f 32f 04.08.M3.B 04.08.M4.B 04.08.S2.B 04.08.S7.B

4 x 12f 48f 04.12.M3.B 04.12.M4.B 04.12.S2.B 04.12.S7.B

6 x 6f 36f 06.06.M3.B 06.06.M4.B 06.06.S2.B 06.06.S7.B

6 x 8f 48f 06.08.M3.B 06.08.M4.B 06.08.S2.B 06.08.S7.B

6 x 12f 72f 06.12.M3.B 06.12.M4.B 06.12.S2.B 06.12.S7.B

UT8x1,7GF Ø 10,0 Eca 8 x 8f 64f 08.08.M3.B 08.08.M4.B 08.08.S2.B 08.08.S7.B

8 x 12f 96f 08.12.M3.B 08.12.M4.B 08.12.S2.B 08.12.S7.B

UT3x1,7GF Ø 12,2 Eca 12 x 8f 96f 12.08.M3.B 12.08.M4.B 12.08.S2.B 12.08.S7.B

12 x 12f 144f 12.12.M3.B 12.12.M4.B R851127 12.12.S7.B

UT9x1,7GF Ø 12,7 Eca

18 x 6f 108f 18.06.M3.B 18.06.M4.B 18.06.S2.B 18.06.S7.B

18 x 8f 144f 18.08.M3.B 18.08.M4.B 18.08.S2.B 18.08.S7.B

18 x 12f 216f 18.12.M3.B 18.12.M4.B 18.12.S2.B 18.12.S7.B

Order code e.g.: UT6x1,7GF 06.06.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Multi Loose Tube Cables

Page 94: Fiber Optic Cables 2018

94

R&M generates added value. Connectivity that matters.Cable construction code DIN code

OT.x2,3GH xx.yy.zz.c A-DQ(BN)2Y wbg nx2,3

1. FRP central strength member2. Water swellable yarn3. Gel filled PBT loose tube with optical fibers4. Water swellable e-glass yarn5. Rip-cord6. HDPE UV stable outer jacket

Cable general description

Multi Loose Tube non-metallic cable with improved rodent protection for outdoor duct installation.

Construction and dimensions OT6x2,3GH OT8x2,3GH OT3x2,3GH OT9x2,3GH

Max. fiber count (12 fibers/tube) 72 96 144 216

Loose-tubes count 6 8 12 18(6+12)-two layers

Loose tube nominal diameter (mm) 2,3 2,3 2,3 2,3

FRP/coat. CSM nominal thickness (mm) 2,5 2,5 / 3,9 2,8 / 6,7 2,5

Outer jacket nominal thickness (mm) 1,4 1,4 1,4 1,4

Cable nominal outer diameter (mm) 11,0 12,5 15,3 15,7

Cable informative weight (kg/km) 100 130 190 195

Standard put-up length (m) 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5%

Outer jacket

Material UV stable HDPE

Jacket colour Black

Sheath marking Ink-Jet, white

Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink

Loose-tube colour coding 1.red, 2.green (in each layer), rest of tubes white (fillers uncoloured or black)

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

All-dielectric Duct Cables with improved rodent protection

OT.x2,3GH

Page 95: Fiber Optic Cables 2018

95

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1

OT6x.. OT8x.. OT3x.. OT9x..

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

longterm

1100 N

1200 N

1500 N

1500N

shortterm

3500 N

4000 N

5000 N

5000N

Crush EN 60794-1-21:E3A 1000 N/100mm (long term)2000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 10 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -40°C ÷ 70°C Δα ≤ 0,05 dB

Temperature range of use

-5°C ÷ 50°C-40°C ÷ 70°C-40°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage

* EN 60794-3-10, EN 60794-3-11 Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count OM3 OM4 G652.D G657.A1

OT6x2,3GH Ø 11,0

4 x 8f 32f 04.08.M3.B 04.08.M4.B 04.08.S2.B 04.08.S7.B

4 x 12f 48f 04.12.M3.B 04.12.M4.B 04.12.S2.B 04.12.S7.B

6 x 6f 36f 06.06.M3.B 06.06.M4.B 06.06.S2.B 06.06.S7.B

6 x 8f 48f 06.08.M3.B 06.08.M4.B 06.08.S2.B 06.08.S7.B

6 x 12f 72f 06.12.M3.B 06.12.M4.B 06.12.S2.B 06.12.S7.B

OT8x2,3GH Ø 12,5 8 x 8f 64f 08.08.M3.B 08.08.M4.B 08.08.S2.B 08.08.S7.B

8 x 12f 96f 08.12.M3.B 08.12.M4.B 08.12.S2.B 08.12.S7.B

OT3x2,3GH Ø 15,3 12 x 8f 96f 12.08.M3.B 12.08.M4.B 12.08.S2.B 12.08.S7.B

12 x 12f 144f 12.12.M3.B 12.12.M4.B R851128 12.12.S7.B

OT9x2,3GH Ø 15,7

18 x 6f 108f 18.06.M3.B 18.06.M4.B 18.06.S2.B 18.06.S7.B

18 x 8f 144f 18.08.M3.B 18.08.M4.B 18.08.S2.B 18.08.S7.B

18 x 12f 216f 18.12.M3.B 18.12.M4.B 18.12.S2.B 18.12.S7.B

Order code e.g.: OT6x2,3GH 06.06.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Multi Loose Tube Cables

Page 96: Fiber Optic Cables 2018

96

R&M generates added value. Connectivity that matters.Cable construction code DIN code

UT.x2,3GF xx.yy.zz.c J/A-DQ(BN)H wbg nx2,3

1. FRP central strength member2. Water swellable yarn3. Gel filled PBT loose tube with optical fibers4. Water swellable e-glass yarn5. Rip-cord6. FRLSZH UV stable outer jacket

Cable general description

Multi Loose Tube non-metallic cable with improved rodent protection for indoor or outdoor duct installation.

Construction and dimensions OT6x2,3GF OT8x2,3GF OT3x2,3GF OT9x2,3GF

Max. fiber count (12 fibers/tube) 72 96 144 216

Loose-tubes count 6 8 12 18(6+12)-two layers

Loose tube nominal diameter (mm) 2,3 2,3 2,3 2,3

FRP/coat. CSM nominal thickness (mm) 2,5 2,5 / 3,9 2,8 / 6,7 2,5

Outer jacket nominal thickness (mm) 1,4 1,4 1,4 1,4

Cable nominal outer diameter (mm) 11,0 12,5 15,3 15,7

Cable informative weight (kg/km) 120 150 220 230

Standard put-up length (m) 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5%

Outer jacket

Material UV stable FRLSZH

Jacket colour Black. Other colours available on request

Sheath marking Ink-Jet, white or black depending on the jacket colour

Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink

Loose-tube colour coding 1.red, 2.green (in each layer), rest of tubes white (fillers uncoloured or black)

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

All-dielectric Duct Cables with improved rodent protection

UT.x2,3GF

Page 97: Fiber Optic Cables 2018

97

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1

UT6x.. UT8x.. UT3x.. UT9x..

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

longterm

1100 N

1200 N

1500 N

1500N

shortterm

3500 N

4000 N

5000 N

5000N

Crush EN 60794-1-21:E3A 1000 N/100mm (long term)2000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 10 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -40°C ÷ 70°C Δα ≤ 0,05 dB

Temperature range of use

-5°C ÷ 50°C-40°C ÷ 70°C-40°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage

* EN 60794-3-10, EN 60794-3-11

Fire performance

Flammability - cable bundle EN 60332-3-22 (cat.A) Pass

Smoke density EN 61034-1, EN 61034-2 Pass

Halogen Free, Acid gases EN 60754-2 Pass

Euro classification to CPR EN 50575, EN 13501-6 Eca

Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count OM3 OM4 G652.D G657.A1

UT6x2,3GF Ø 11,0 Eca

4 x 8f 32f 04.08.M3.B 04.08.M4.B 04.08.S2.B 04.08.S7.B

4 x 12f 48f 04.12.M3.B 04.12.M4.B 04.12.S2.B 04.12.S7.B

6 x 6f 36f 06.06.M3.B 06.06.M4.B 06.06.S2.B 06.06.S7.B

6 x 8f 48f 06.08.M3.B 06.08.M4.B 06.08.S2.B 06.08.S7.B

6 x 12f 72f 06.12.M3.B 06.12.M4.B 06.12.S2.B 06.12.S7.B

UT8x2,3GF Ø 12,5 Eca 8 x 8f 64f 08.08.M3.B 08.08.M4.B 08.08.S2.B 08.08.S7.B

8 x 12f 96f 08.12.M3.B 08.12.M4.B 08.12.S2.B 08.12.S7.B

UT3x2,3GF Ø 15,3 Eca 12 x 8f 96f 12.08.M3.B 12.08.M4.B 12.08.S2.B 12.08.S7.B

12 x 12f 144f 12.12.M3.B 12.12.M4.B R851129 12.12.S7.B

UT9x2,3GF Ø 15,7 Eca

18 x 6f 108f 18.06.M3.B 18.06.M4.B 18.06.S2.B 18.06.S7.B

18 x 8f 144f 18.08.M3.B 18.08.M4.B 18.08.S2.B 18.08.S7.B

18 x 12f 216f 18.12.M3.B 18.12.M4.B 18.12.S2.B 18.12.S7.B

Order code e.g.: UT8x2,3GF 08.08.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Multi Loose Tube Cables

Page 98: Fiber Optic Cables 2018

98

R&M generates added value. Connectivity that matters.Cable construction code DIN code

OT.x2,3LWH xx.yy.zz.c A-DQ2YB2Y (R...vzk) nx2,3

1. FRP central strength member2. Water swellable yarn3. Rip-cord4. Gel filled PBT loose tube with optical fibers5. LDPE UV stable inner jacket6. Zn galvanized steel wire armour fixed by PET tape7. HDPE UV stable outer jacket

Cable general description

Multi Loose Tube steel wire armoured cable with two jackets for outdoor duct or direct buried installation. This cable construction offers excellent mechanical and full rodent protection.

Construction and dimensions OT6x2,3LWH OT8x2,3LWH OT3x2,3LWH

Max. fiber count (12 fibers/tube) 72 96 144

Loose-tubes count 6 8 12

Loose tube nominal diameter (mm) 2,3 2,3 2,3

FRP/coat. CSM nominal thickness (mm) 2,5 2,5 / 3,8 2,5 / 6,7

Inner jacket nominal thickness (mm) 1,0 1,0 1,0

Steel wire nominal diameter (mm) 1,0 1,0 1,3

Outer jacket nominal thickness (mm) 1,3 1,3 1,3

Cable nominal outer diameter (mm) 14,5 15,8 19,4

Cable informative weight (kg/km) 330 385 610

Standard put-up length (m) 2100/4100 ± 5% 2100/4100 ± 5% 2100/4100 ± 5%

Outer jacket

Material UV stable HDPE

Jacket colour Black

Sheath marking Ink-Jet, white

Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink

Loose-tube colour coding 1.red, 2.green (in each layer), rest of tubes white (fillers uncoloured or black)

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

Steel Wire Armoured Cables SWA

OT.x2,3LWH

Page 99: Fiber Optic Cables 2018

99

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1

OT6x.. OT8x.. OT3x..

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

longterm n.a. n.a. n.a.

shortterm

5000 N

6000 N

8000 N

Crush EN 60794-1-21:E3A 2000 N/100mm (long term)4000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 25 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -40°C ÷ 70°C Δα ≤ 0,05 dB

Temperature range of use

-5°C ÷ 50°C-40°C ÷ 70°C-40°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage under inner sheath

* EN 60794-3-10, EN 60794-3-11 Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count OM3 OM4 G652.D G657.A1

OT6x2,3LWH Ø 14,5

4 x 8f 32f 04.08.M3.B 04.08.M4.B 04.08.S2.B 04.08.S7.B

4 x 12f 48f 04.12.M3.B 04.12.M4.B 04.12.S2.B 04.12.S7.B

6 x 8f 48f 06.08.M3.B 06.08.M4.B 06.08.S2.B 06.08.S7.B

6 x 12f 72f 06.12.M3.B 06.12.M4.B 06.12.S2.B 06.12.S7.B

OT8x2,3LWH Ø 15,8 8 x 8f 64f 08.08.M3.B 08.08.M4.B 08.08.S2.B 08.08.S7.B

8 x 12f 96f 08.12.M3.B 08.12.M4.B 08.12.S2.B 08.12.S7.B

OT3x2,3LWH Ø 19,4 12 x 8f 96f 12.08.M3.B 12.08.M4.B 12.08.S2.B 12.08.S7.B

12 x 12f 144f 12.12.M3.B 12.12.M4.B R851130 12.08.S7.B

Order code e.g.: OT6x2,3LWH 06.08.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Multi Loose Tube Cables

Page 100: Fiber Optic Cables 2018

100

R&M generates added value. Connectivity that matters.Cable construction code DIN code

UT.x2,3FWF xx.yy.zz.c J/A-DQHBH (R...vzk) nx2,3

1. FRP central strength member2. Water swellable yarn3. Rip-cord4. Gel filled PBT loose tube with optical fibers5. FRLSZH UV stable inner jacket6. Zn galvanized steel wire armour fixed by PET tape7. FRLSZH UV stable outer jacket

Cable general description

Multi Loose Tube steel wire armoured cable with two jackets for indoor or outdoor duct or direct buried installation.

Construction and dimensions UT6x2,3FWF UT8x2,3FWF UT3x2,3FWF

Max. fiber count (12 fibers/tube) 72 96 144

Loose-tubes count 6 8 12

Loose tube nominal diameter (mm) 2,3 2,3 2,3

FRP/coat. CSM nominal thickness (mm) 2,5 2,5 / 3,8 2,5 / 6,7

Inner jacket nominal thickness (mm) 1,0 1,0 1,0

Steel wire nominal diameter (mm) 1,0 1,0 1,3

Outer jacket nominal thickness (mm) 1,3 1,3 1,3

Cable nominal outer diameter (mm) 14,5 15,8 19,4

Cable informative weight (kg/km) 370 430 670

Standard put-up length (m) 2100/4100 ± 5% 2100/4100 ± 5% 2100/4100 ± 5%

Outer jacket

Material UV stable FRLSZH

Jacket colour Black. Other colours available on request

Sheath marking Ink-Jet, white or black depending on the jacket colour

Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink

Loose-tube colour coding 1.red, 2.green (in each layer), rest of tubes white (fillers uncoloured or black)

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

Steel Wire Armoured Cables SWA

UT.x2,3FWF

Page 101: Fiber Optic Cables 2018

101

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1

UT6x.. UT8x.. UT3x..

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

longterm n.a. n.a. n.a.

shortterm

5000 N

6000 N

8000 N

Crush EN 60794-1-21:E3A 2000 N/100mm (long term)4000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 25 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -40°C ÷ 70°C Δα ≤ 0,05 dB

Temperature range of use

-5°C ÷ 50°C-40°C ÷ 70°C-40°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage under inner sheath

* EN 60794-3-10, EN 60794-3-11

Fire performance

Flammability - cable bundle EN 60332-3-22 (cat.A) Pass

Smoke density EN 61034-1, EN 61034-2 Pass

Halogen Free, Acid gases EN 60754-2 Pass

Euro classification to CPR EN 50575, EN 13501-6 Fca

Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count OM3 OM4 G652.D G657.A1

UT6x2,3FWF Ø 14,5 Fca

4 x 8f 32f 04.08.M3.B 04.08.M4.B 04.08.S2.B 04.08.S7.B

4 x 12f 48f 04.12.M3.B 04.12.M4.B 04.12.S2.B 04.12.S7.B

6 x 8f 48f 06.08.M3.B 06.08.M4.B 06.08.S2.B 06.08.S7.B

6 x 12f 72f 06.12.M3.B 06.12.M4.B 06.12.S2.B 06.12.S7.B

UT8x2,3FWF Ø 15,8 Fca 8 x 8f 64f 08.08.M3.B 08.08.M4.B 08.08.S2.B 08.08.S7.B

8 x 12f 96f 08.12.M3.B 08.12.M4.B 08.12.S2.B 08.12.S7.B

UT3x2,3FWF Ø 19,4 Fca 12 x 8f 96f 12.08.M3.B 12.08.M4.B 12.08.S2.B 12.08.S7.B

12 x 12f 144f 12.12.M3.B 12.12.M4.B R851131 12.08.S7.B

Order code e.g.: UT6x2,3FWF 06.08.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Multi Loose Tube Cables

Page 102: Fiber Optic Cables 2018

102

R&M generates added value. Connectivity that matters.Cable construction code DIN code

OT.x1,7ECH xx.yy.zz.c A-DQ(ZN)(SR)2Y wbg nx1,7

1. FRP central strength member2. Water swellable yarn3. Gel filled PBT loose tube with optical fibers4. Water swellable e-glass yarn5. Rip-cord6. Corrugated steel tape armour7. HDPE UV stable outer jacket

Cable general description

Multi Loose Tube corrugated steel tape armoured cable for outdoor duct or direct buried installation. This cable construction offers full rodent protection.

Construction and dimensions OT6x1,7ECH OT8x1,7ECH OT3x1,7ECH OT9x1,7ECH

Max. fiber count (12 fibers/tube) 72 96 144 216

Loose-tubes count 6 8 12 18(6+12)-two layers

Loose tube nominal diameter (mm) 1,7 1,7 1,7 1,7

FRP/coat. CSM nominal thickness (mm) 1,7 2,8 2,5/5,0 1,7

Outer jacket nominal thickness (mm) 1,3 1,3 1,3 1,3

Cable nominal outer diameter (mm) 11,0 12,0 14,0 14,0

Cable informative weight (kg/km) 115 140 185 185

Standard put-up length (m) 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5%

Outer jacket

Material UV stable HDPE

Jacket colour Black

Sheath marking Ink-Jet, white

Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink

Loose-tube colour coding 1.red, 2.green (in each layer), rest of tubes white (fillers uncoloured or black)

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

Corrugated Steel Tape Armoured Cables CSTA

OT.x1,7ECH

Page 103: Fiber Optic Cables 2018

103

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1

OT6x.. OT8x.. OT3x.. OT9x..

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

longterm

800 N

1200 N

1200 N

1100N

shortterm

2500 N

4000 N

4000 N

3500N

Crush EN 60794-1-21:E3A 2500 N/100mm (long term)5000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 20 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -40°C ÷ 70°C Δα ≤ 0,05 dB

Temperature range of use

-5°C ÷ 50°C-40°C ÷ 70°C-40°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage

* EN 60794-3-10, EN 60794-3-11 Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count OM3 OM4 G652.D G657.A1

OT6x1,7ECH Ø 11,0

4 x 8f 32f 04.08.M3.B 04.08.M4.B 04.08.S2.B 04.08.S7.B

4 x 12f 48f 04.12.M3.B 04.12.M4.B 04.12.S2.B 04.12.S7.B

6 x 6f 36f 06.06.M3.B 06.06.M4.B 06.06.S2.B 06.06.S7.B

6 x 8f 48f 06.08.M3.B 06.08.M4.B 06.08.S2.B 06.08.S7.B

6 x 12f 72f 06.12.M3.B 06.12.M4.B 06.12.S2.B 06.12.S7.B

OT8x1,7ECH Ø 12,0 8 x 8f 64f 08.08.M3.B 08.08.M4.B 08.08.S2.B 08.08.S7.B

8 x 12f 96f 08.12.M3.B 08.12.M4.B 08.12.S2.B 08.12.S7.B

OT3x1,7ECH Ø 14,0 12 x 8f 96f 12.08.M3.B 12.08.M4.B 12.08.S2.B 12.08.S7.B

12 x 12f 144f 12.12.M3.B 12.12.M4.B R851129 12.12.S7.B

OT9x1,7ECH Ø 14,0

18 x 6f 108f 18.06.M3.B 18.06.M4.B 18.06.S2.B 18.06.S7.B

18 x 8f 144f 18.08.M3.B 18.08.M4.B 18.08.S2.B 18.08.S7.B

18 x 12f 216f 18.12.M3.B 18.12.M4.B R851132 18.12.S7.B

Order code e.g.: OT6x1,7ECH 04.08.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Multi Loose Tube Cables

Page 104: Fiber Optic Cables 2018

104

R&M generates added value. Connectivity that matters.Cable construction code DIN code

UT.x1,7ECF xx.yy.zz.c J/A-DQ(ZN)(SR)H wbg nx1,7

1. FRP central strength member2. Water swellable yarn3. Gel filled PBT loose tube with optical fibers4. Water swellable e-glass yarn5. Rip-cord6. Corrugated steel tape armour7. FRLSZH UV stable outer jacket

Cable general description

Multi Loose Tube corrugated steel tape armoured cable for indoor or outdoor duct or direct buried installation. This cable construction offers full rodent protection.

Construction and dimensions OT6x1,7ECF OT8x1,7ECF OT3x1,7ECF OT9x1,7ECF

Max. fiber count (12 fibers/tube) 72 96 144 216

Loose-tubes count 6 8 12 18(6+12)-two layers

Loose tube nominal diameter (mm) 1,7 1,7 1,7 1,7

FRP/coat. CSM nominal thickness (mm) 1,7 2,8 2,5/5,0 1,7

Outer jacket nominal thickness (mm) 1,3 1,3 1,3 1,3

Cable nominal outer diameter (mm) 11,0 12,0 14,0 14,0

Cable informative weight (kg/km) 135 165 210 210

Standard put-up length (m) 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5%

Outer jacket

Material UV stable FRLSZH

Jacket colour Black. Other colours available on request

Sheath marking Ink-Jet, white or black depending on the jacket colour

Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink

Loose-tube colour coding 1.red, 2.green (in each layer), rest of tubes white (fillers uncoloured or black)

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

Corrugated Steel Tape Armoured Cables CSTA

UT.x1,7ECF

Page 105: Fiber Optic Cables 2018

105

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1

UT6x.. UT8x.. UT3x.. UT9x..

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

longterm

800N

1200 N

1200 N

1100N

shortterm

2500 N

4000 N

4000 N

3500N

Crush EN 60794-1-21:E3A 2500 N/100mm (long term)5000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 20 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -40°C ÷ 70°C Δα ≤ 0,05 dB

Temperature range of use

-5°C ÷ 50°C-40°C ÷ 70°C-40°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage

* EN 60794-3-10, EN 60794-3-11

Fire performance

Flammability - cable bundle EN 60332-3-22 (cat.A) Pass

Smoke density EN 61034-1, EN 61034-2 Pass

Halogen Free, Acid gases EN 60754-2 Pass

Euro classification to CPR EN 50575, EN 13501-6 Fca

Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count OM3 OM4 G652.D G657.A1

UT6x1,7ECF Ø 11,0 Fca

4 x 8f 32f 04.08.M3.B 04.08.M4.B 04.08.S2.B 04.08.S7.B

4 x 12f 48f 04.12.M3.B 04.12.M4.B 04.12.S2.B 04.12.S7.B

6 x 6f 36f 06.06.M3.B 06.06.M4.B 06.06.S2.B 06.06.S7.B

6 x 8f 48f 06.08.M3.B 06.08.M4.B 06.08.S2.B 06.08.S7.B

6 x 12f 72f 06.12.M3.B 06.12.M4.B 06.12.S2.B 06.12.S7.B

UT8x1,7ECF Ø 12,0 Fca 8 x 8f 64f 08.08.M3.B 08.08.M4.B 08.08.S2.B 08.08.S7.B

8 x 12f 96f 08.12.M3.B 08.12.M4.B 08.12.S2.B 08.12.S7.B

UT3x1,7ECF Ø 14,0 Fca 12 x 8f 96f 12.08.M3.B 12.08.M4.B 12.08.S2.B 12.08.S7.B

12 x 12f 144f 12.12.M3.B 12.12.M4.B R851129 12.12.S7.B

UT9x1,7ECF Ø 14,0 Fca

18 x 6f 108f 18.06.M3.B 18.06.M4.B 18.06.S2.B 18.06.S7.B

18 x 8f 144f 18.08.M3.B 18.08.M4.B 18.08.S2.B 18.08.S7.B

18 x 12f 216f 18.12.M3.B 18.12.M4.B R851133 18.12.S7.B

Order code e.g.: UT6x1,7ECF 06.06.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Multi Loose Tube Cables

Page 106: Fiber Optic Cables 2018

106

R&M generates added value. Connectivity that matters.Cable construction code DIN code

OT.x1,7ELCH xx.yy.zz.c A-DQ(ZN)2Y(SR)2Y wbg nx1,7

1. FRP central strength member2. Water swellable yarn3. Gel filled PBT loose tube with optical fibers4. Water swellable e-glass yarn5. Rip-cord6. LDPE UV stable inner jacket7. Corrugated steel tape armour8. HDPE UV stable outer jacket

Cable general description

Multi Loose Tube corrugated steel tape armoured cable with two jackets for outdoor duct or direct buried installation. This cable construction offers excellent mechanical and full rodent protection.

Construction and dimensions OT6x1,7ELCH OT8x1,7ELCH OT3x1,7ELCH OT9x1,7ELCH

Max. fiber count (12 fibers/tube) 72 96 144 216

Loose-tubes count 6 8 12 18(6+12)-two layers

Loose tube nominal diameter (mm) 1,7 1,7 1,7 1,7

FRP/coat. CSM nominal thickness (mm) 1,7 2,8 2,5/5,0 1,7

Inner jacket nominal thickness (mm) 0,9 0,9 0,9 0,9

Outer jacket nominal thickness (mm) 1,3 1,3 1,3 1,3

Cable nominal outer diameter (mm) 12,1 13,1 15,1 16,1

Cable informative weight (kg/km) 145 175 220 240

Standard put-up length (m) 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5%

Outer jacket

Material UV stable HDPE

Jacket colour Black

Sheath marking Ink-Jet, white

Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink

Loose-tube colour coding 1.red, 2.green (in each layer), rest of tubes white (fillers uncoloured or black)

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

Corrugated Steel Tape Armoured Cables CSTA

OT.x1,7ELCH

Page 107: Fiber Optic Cables 2018

107

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1

OT6x.. OT8x.. OT3x.. OT9x..

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

longterm

800 N

1200 N

1200 N

1200N

shortterm

2500 N

4000 N

4000 N

4000N

Crush EN 60794-1-21:E3A 2500 N/100mm (long term)5000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 25 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -40°C ÷ 70°C Δα ≤ 0,05 dB

Temperature range of use

-5°C ÷ 50°C-40°C ÷ 70°C-40°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage under inner sheath

* EN 60794-3-10, EN 60794-3-11 Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count OM3 OM4 G652.D G657.A1

OT6x1,7ELCH Ø 12,1

4 x 8f 32f 04.08.M3.B 04.08.M4.B 04.08.S2.B 04.08.S7.B

4 x 12f 48f 04.12.M3.B 04.12.M4.B 04.12.S2.B 04.12.S7.B

6 x 6f 36f 06.06.M3.B 06.06.M4.B 06.06.S2.B 06.06.S7.B

6 x 8f 48f 06.08.M3.B 06.08.M4.B 06.08.S2.B 06.08.S7.B

6 x 12f 72f 06.12.M3.B 06.12.M4.B 06.12.S2.B 06.12.S7.B

OT8x1,7ELCH Ø 13,1 8 x 8f 64f 08.08.M3.B 08.08.M4.B 08.08.S2.B 08.08.S7.B

8 x 12f 96f 08.12.M3.B 08.12.M4.B 08.12.S2.B 08.12.S7.B

OT3x1,7ELCH Ø 15,1 12 x 8f 96f 12.08.M3.B 12.08.M4.B 12.08.S2.B 12.08.S7.B

12 x 12f 144f 12.12.M3.B 12.12.M4.B R851129 12.12.S7.B

OT9x1,7ELCH Ø 16,1

18 x 6f 108f 18.06.M3.B 18.06.M4.B 18.06.S2.B 18.06.S7.B

18 x 8f 144f 18.08.M3.B 18.08.M4.B 18.08.S2.B 18.08.S7.B

18 x 12f 216f 18.12.M3.B 18.12.M4.B R851134 18.12.S7.B

Order code e.g.: OT6x1,7ELCH 18.06.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Multi Loose Tube Cables

Page 108: Fiber Optic Cables 2018

108

R&M generates added value. Connectivity that matters.Cable construction code DIN code

UT.x1,7EFCF xx.yy.zz.c J/A-DQ(ZN)H(SR)H wbg nx1,7

1. FRP central strength member2. Water swellable yarn3. Gel filled PBT loose tube with optical fibers4. Water swellable e-glass yarn5. Rip-cord6. FRLSZH UV stable inner jacket7. Corrugated steel tape armour8. FRLSZH UV stable outer jacket

Cable general description

Multi Loose Tube corrugated steel tape armoured cable with two jackets for indoor or outdoor duct or direct buried installation. This cable construction offers excellent mechanical and full rodent protection.

Construction and dimensions OT6x1,7EFCF OT8x1,7EFCF OT3x1,7EFCF OT9x1,7EFCF

Max. fiber count (12 fibers/tube) 72 96 144 216

Loose-tubes count 6 8 12 18(6+12)-two layers

Loose tube nominal diameter (mm) 1,7 1,7 1,7 1,7

FRP/coat. CSM nominal thickness (mm) 1,7 2,8 2,5/5,0 1,7

Inner jacket nominal thickness (mm) 0,9 0,9 0,9 0,9

Outer jacket nominal thickness (mm) 1,3 1,3 1,3 1,3

Cable nominal outer diameter (mm) 12,1 13,1 15,1 16,1

Cable informative weight (kg/km) 180 210 270 290

Standard put-up length (m) 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5%

Outer jacket

Material UV stable FRLSZH

Jacket colour Black. Other colours available on request

Sheath marking Ink-Jet, white or black depending on the jacket colour

Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink

Loose-tube colour coding 1.red, 2.green (in each layer), rest of tubes white (fillers uncoloured or black)

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

Corrugated Steel Tape Armoured Cables CSTA

UT.x1,7EFCF

Page 109: Fiber Optic Cables 2018

109

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1

UT6x.. UT8x.. UT3x.. UT9x..

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

longterm

800N

1200 N

1200 N

1100N

shortterm

2500 N

4000 N

4000 N

4000N

Crush EN 60794-1-21:E3A 2500 N/100mm (long term)5000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 25 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -40°C ÷ 70°C Δα ≤ 0,05 dB

Temperature range of use

-5°C ÷ 50°C-40°C ÷ 70°C-40°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage under inner sheath

* EN 60794-3-10, EN 60794-3-11

Fire performance

Flammability - cable bundle EN 60332-3-22 (cat.A) Pass

Smoke density EN 61034-1, EN 61034-2 Pass

Halogen Free, Acid gases EN 60754-2 Pass

Euro classification to CPR EN 50575, EN 13501-6 Fca

Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count OM3 OM4 G652.D G657.A1

UT6x1,7EFCF Ø 12,1 Fca

4 x 8f 32f 04.08.M3.B 04.08.M4.B 04.08.S2.B 04.08.S7.B

4 x 12f 48f 04.12.M3.B 04.12.M4.B 04.12.S2.B 04.12.S7.B

6 x 6f 36f 06.06.M3.B 06.06.M4.B 06.06.S2.B 06.06.S7.B

6 x 8f 48f 06.08.M3.B 06.08.M4.B 06.08.S2.B 06.08.S7.B

6 x 12f 72f 06.12.M3.B 06.12.M4.B 06.12.S2.B 06.12.S7.B

UT8x1,7EFCF Ø 13,1 Fca 8 x 8f 64f 08.08.M3.B 08.08.M4.B 08.08.S2.B 08.08.S7.B

8 x 12f 96f 08.12.M3.B 08.12.M4.B 08.12.S2.B 08.12.S7.B

UT3x1,7EFCF Ø 15,1 Fca 12 x 8f 96f 12.08.M3.B 12.08.M4.B 12.08.S2.B 12.08.S7.B

12 x 12f 144f 12.12.M3.B 12.12.M4.B R851129 12.12.S7.B

UT9x1,7EFCF Ø 16,1 Fca

18 x 6f 108f 18.06.M3.B 18.06.M4.B 18.06.S2.B 18.06.S7.B

18 x 8f 144f 18.08.M3.B 18.08.M4.B 18.08.S2.B 18.08.S7.B

18 x 12f 216f 18.12.M3.B 18.12.M4.B R851135 18.12.S7.B

Order code e.g.: UT3x1,7EFCF 12.08.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Multi Loose Tube Cables

Page 110: Fiber Optic Cables 2018

110

R&M generates added value. Connectivity that matters.Cable construction code DIN code

QT.x2,3GF xx.yy.zz.c J/A-DQ(BN)H wbg nx2,3 fr

1. FRP central strength member2. Water swellable yarn3. Gel filled PBT loose tube with optical fibers4. Fire-resistant tape5. Water swellable e-glass yarn6. Rip-cord7. FRLSZH UV stable outer jacket

Cable general description

Multi Loose Tube non-metallic fire-resistant cable with improved rodent protection for indoor or outdoor duct installation.

Construction and dimensions QT6x2,3GF QT8x2,3GF QT3x2,3GF

Max. fiber count (12 fibers/tube) 72 96 144

Loose-tubes count 6 8 12

Loose tube nominal diameter (mm) 2,3 2,3 2,3

FRP/coat. CSM nominal thickness (mm) 2,8 2,5 / 4,5 2,8 / 7,8

Outer jacket nominal thickness (mm) 1,8 1,8 1,8

Cable nominal outer diameter (mm) 13,0 14,6 18,0

Cable informative weight (kg/km) 180 225 340

Standard put-up length (m) 2100/4100 ± 5% 2100/4100 ± 5% 2100/4100 ± 5%

Outer jacket

Material UV stable FRLSZH

Jacket colour Black. Other colours available on request

Sheath marking Ink-Jet, white or black depending on the jacket colour

Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink

Loose-tube colour coding 1.red, 2.green (in each layer), rest of tubes white (fillers uncoloured or black)

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

Fire Resistant Cables All-dielectric Non-armoured

QT.x2,3GF

Page 111: Fiber Optic Cables 2018

111

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1

UT6x.. UT8x.. UT3x..

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

longterm

1400N

1400N

1800N

shortterm

4500 N

4500 N

6000 N

Crush EN 60794-1-21:E3A 1000 N/100mm (long term)2000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 10 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -40°C ÷ 70°C Δα ≤ 0,05 dB

Temperature range of use

-5°C ÷ 50°C-40°C ÷ 70°C-40°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage

* EN 60794-3-10, EN 60794-3-11

Fire performance

Fire resistance EN 60331-25 (180 min at 750°C) Pass

Flammability - cable bundle EN 60332-3-22 (cat.A) Pass

Smoke density EN 61034-1, EN 61034-2 Pass

Halogen Free, Acid gases EN 60754-2 Pass

Euro classification to CPR EN 50575, EN 13501-6 Fca

Cable expected lifetime / min. 30 yearsOrder information

Construction Diameter CPR Fiber count OM3 OM4 G652.D G657.A1

QT6x2,3GF Ø 13,0 Fca

4 x 8f 32f 04.08.M3.B 04.08.M4.B 04.08.S2.B 04.08.S7.B

4 x 12f 48f 04.12.M3.B 04.12.M4.B 04.12.S2.B 04.12.S7.B

6 x 8f 48f 06.08.M3.B 06.08.M4.B 06.08.S2.B 06.08.S7.B

6 x 12f 72f 06.12.M3.B 06.12.M4.B 06.12.S2.B 06.12.S7.B

QT8x2,3GF Ø 14,6 Fca 8 x 8f 64f 08.08.M3.B 08.08.M4.B 08.08.S2.B 08.08.S7.B

8 x 12f 96f 08.12.M3.B 08.12.M4.B 08.12.S2.B 08.12.S7.B

QT3x2,3GF Ø 18,0 Fca 12 x 8f 96f 12.08.M3.B 12.08.M4.B 12.08.S2.B 12.08.S7.B

12 x 12f 144f 12.12.M3.B 12.12.M4.B R851136 12.12.S7.B

Order code e.g.: QT6x2,3GF 04.08.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Multi Loose Tube Cables

Page 112: Fiber Optic Cables 2018

112

R&M generates added value. Connectivity that matters.

Fire Resistant Cables Corrugated Steel Tape Armoured

QT.x2,3EFCF

Cable construction code DIN code

QT.x2,3EFCF xx.yy.zz.c J/A-DQ(ZN)H(SR)H wbg nx2,3 fr

1. FRP central strength member2. Water swellable yarn3. Gel filled PBT loose tube with optical fibers4. Fire-resistant tape5. Water swellable e-glass yarn6. Rip-cord7. FRLSZH UV stable inner jacket8. Corrugated steel tape armour9. FRLSZH UV stable outer jacket

Cable general description

Multi Loose Tube fire resistant corrugated steel tape armoured cable with two jackets for indoor or outdoor duct or direct buried installation. This cable construction offers excellent mechanical and full rodent protection.

Construction and dimensions QT6x2,3EFCF QT8x2,3EFCF QT3x2,3EFCF

Max. fiber count (12 fibers/tube) 72 96 144

Loose-tubes count 6 8 12

Loose tube nominal diameter (mm) 2,3 2,3 2,3

FRP/coat. CSM nominal thickness (mm) 2,8 2,5 / 4,5 2,8 / 7,8

Outer jacket nominal thickness (mm) 1,0 1,0 1,0

Cable nominal outer diameter (mm) 16,5 17,5 21,5

Cable informative weight (kg/km) 300 350 500

Standard put-up length (m) 2100/4100 ± 5% 2100/4100 ± 5% 2100/4100 ± 5%

Outer jacket

Material UV stable FRLSZH

Jacket colour Black. Other colours available on request

Sheath marking Ink-Jet, white or black depending on the jacket colour

Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink

Loose-tube colour coding 1.red, 2.green (in each layer), rest of tubes white (fillers uncoloured or black)

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

Page 113: Fiber Optic Cables 2018

113

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1

QT6x.. QT8x.. QT3x..

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

longterm

900N

900N

1100N

shortterm

3000 N

3000 N

3500 N

Crush EN 60794-1-21:E3A 2500 N/100mm (long term)5000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 20 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -40°C ÷ 70°C Δα ≤ 0,05 dB

Temperature range of use

-5°C ÷ 50°C-40°C ÷ 70°C-40°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage under inner sheath

* EN 60794-3-10, EN 60794-3-11

Fire performance

Fire resistance EN 60331-25 (180 min at 750°C) Pass

Flammability - cable bundle EN 60332-3-22 (cat.A) Pass

Smoke density EN 61034-1, EN 61034-2 Pass

Halogen Free, Acid gases EN 60754-2 Pass

Euro classification to CPR EN 50575, EN 13501-6 Fca

Cable expected lifetime / min. 30 yearsOrder information

Construction Diameter CPR Fiber count OM3 OM4 G652.D G657.A1

QT6x2,3EFCF Ø 16,5 Fca

4 x 8f 32f 04.08.M3.B 04.08.M4.B 04.08.S2.B 04.08.S7.B

4 x 12f 48f 04.12.M3.B 04.12.M4.B 04.12.S2.B 04.12.S7.B

6 x 8f 48f 06.08.M3.B 06.08.M4.B 06.08.S2.B 06.08.S7.B

6 x 12f 72f 06.12.M3.B 06.12.M4.B 06.12.S2.B 06.12.S7.B

QT8x2,3EFCF Ø 17,5 Fca 8 x 8f 64f 08.08.M3.B 08.08.M4.B 08.08.S2.B 08.08.S7.B

8 x 12f 96f 08.12.M3.B 08.12.M4.B 08.12.S2.B 08.12.S7.B

QT3x2,3EFCF Ø 21,5 Fca 12 x 8f 96f 12.08.M3.B 12.08.M4.B 12.08.S2.B 12.08.S7.B

12 x 12f 144f 12.12.M3.B 12.12.M4.B R851137 12.12.S7.B

Order code e.g.: QT8x2,3EFCF 08.08.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Multi Loose Tube Cables

Page 114: Fiber Optic Cables 2018

114

R&M generates added value. Connectivity that matters.Cable construction code DIN code

QT.x2,3FWF xx.yy.zz.c J/A-DQHBH (R...vzk) nx2,3 fr

1. FRP central strength member2. Water swellable yarn3. Gel filled PBT loose tube with optical fibers4. Fire-resistant tape5. Rip-cord6. FRLSZH UV stable inner jacket7. Zn galvanized steel wire armour fixed by PET tape8. FRLSZH UV stable outer jacket

Cable general description

Multi Loose Tube fire resistant steel wire armoured cable with two jackets for indoor or outdoor duct or direct buried installation. This cable construction offers excellent mechanical and full rodent protection.

Construction and dimensions QT6x2,3FWF QT8x2,3FWF QT3x2,3FWF

Max. fiber count (12 fibers/tube) 72 96 144

Loose-tubes count 6 8 12

Loose tube nominal diameter (mm) 2,3 2,3 2,3

FRP/coat. CSM nominal thickness (mm) 2,8 2,5 / 4,5 2,5 / 7,8

Inner jacket nominal thickness (mm) 1,0 1,0 1,0

Steel wire nominal diameter (mm) 1,0 1,2 1,4

Outer jacket nominal thickness (mm) 1,4 1,4 1,4

Cable nominal outer diameter (mm) 15,6 17,7 21,1

Cable informative weight (kg/km) 440 570 800

Standard put-up length (m) 2100/4100 ± 5% 2100/4100 ± 5% 2100/4100 ± 5%

Outer jacket

Material UV stable FRLSZH

Jacket colour Black. Other colours available on request

Sheath marking Ink-Jet, white or black depending on the jacket colour

Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink

Loose-tube colour coding 1.red, 2.green (in each layer), rest of tubes white (fillers uncoloured or black)

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

Fire Resistant Cables Steel Wire Armoured Cables

QT.x2,3FWF

Page 115: Fiber Optic Cables 2018

115

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1

QT6x.. QT8x.. QT3x..

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

longterm n.a. n.a. n.a.

shortterm

5000 N

8000 N

10000 N

Crush EN 60794-1-21:E3A 2000 N/100mm (long term)4000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 25 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -40°C ÷ 70°C Δα ≤ 0,05 dB

Temperature range of use

-5°C ÷ 50°C-40°C ÷ 70°C-40°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage under inner sheath

* EN 60794-3-10, EN 60794-3-11

Fire performance

Fire resistance EN 60331-25 (180 min at 750°C) Pass

Flammability - cable bundle EN 60332-3-22 (cat.A) Pass

Smoke density EN 61034-1, EN 61034-2 Pass

Halogen Free, Acid gases EN 60754-2 Pass

Euro classification to CPR EN 50575, EN 13501-6 Fca

Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count OM3 OM4 G652.D G657.A1

QT6x2,3FWF Ø 15,6 Fca

4 x 8f 32f 04.08.M3.B 04.08.M4.B 04.08.S2.B 04.08.S7.B

4 x 12f 48f 04.12.M3.B 04.12.M4.B 04.12.S2.B 04.12.S7.B

6 x 8f 48f 06.08.M3.B 06.08.M4.B 06.08.S2.B 06.08.S7.B

6 x 12f 72f 06.12.M3.B 06.12.M4.B 06.12.S2.B 06.12.S7.B

QT8x2,3FWF Ø 17,7 Fca 8 x 8f 64f 08.08.M3.B 08.08.M4.B 08.08.S2.B 08.08.S7.B

8 x 12f 96f 08.12.M3.B 08.12.M4.B 08.12.S2.B 08.12.S7.B

QT3x2,3FWF Ø 21,1 Fca 12 x 8f 96f 12.08.M3.B 12.08.M4.B 12.08.S2.B 12.08.S7.B

12 x 12f 144f 12.12.M3.B 12.12.M4.B R851138 12.12.S7.B

Order code e.g.: QT8x2,3FWF 08.08.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Multi Loose Tube Cables

Page 116: Fiber Optic Cables 2018

116

R&M generates added value. Connectivity that matters.FTTx Constructions.

Page 117: Fiber Optic Cables 2018

117

Page 118: Fiber Optic Cables 2018

118

R&M generates added value. Connectivity that matters.

FTTx Constructions Overview

Microcables

MT1RF 120 MT1RF xx.yy.zz.c indoor/outdoor 4 fibers 1 1.2

Flat self-supporting cables

ST1fH 122 ST1fH xx.yy.zz.c indoor/outdoor 12 fibers 1 1.9

Flat self-supporting cables

ST2fH 124 ST2fH xx.yy.zz.c indoor/outdoor 24 fibers 2 1.9

Non-metallic drop cables

UAF250 126 UAF250 00.yy.zz.c indoor/outdoor 6 fibers 12 fibers

0 n.a.

Non-metallic drop cables

UAF1000 128 UAF1000 00.yy.zz.c indoor/outdoor 2 fibers 8 fibers 12 fibers

0 n.a.

Cable type Construction Page Construction code ApplicationFiber count[fibers]

Loose tubes count

Loose tube nominal Ø [mm]

Jacket material

Euro classification to CPR

Nominal cable Ø [mm]

Cable weight [kg/km]

Tensile performance [N]

Crush [N/100mm]

Temperatur range in operation

Fire resistance – EN 60331-25

Page 119: Fiber Optic Cables 2018

119

Microcables

MT1RF 120 MT1RF xx.yy.zz.c indoor/outdoor 4 fibers 1 1.2

Flat self-supporting cables

ST1fH 122 ST1fH xx.yy.zz.c indoor/outdoor 12 fibers 1 1.9

Flat self-supporting cables

ST2fH 124 ST2fH xx.yy.zz.c indoor/outdoor 24 fibers 2 1.9

Non-metallic drop cables

UAF250 126 UAF250 00.yy.zz.c indoor/outdoor 6 fibers 12 fibers

0 n.a.

Non-metallic drop cables

UAF1000 128 UAF1000 00.yy.zz.c indoor/outdoor 2 fibers 8 fibers 12 fibers

0 n.a.

FRLSZH Fca 3.0 11.0 150 500 -20°C to 70°C

HDPE 8.0 x 4.0 38.0 1'600 4'000 -20°C to 70°C

HDPE 9.8 x 4.0 59.0 1'600 4'000 -20°C to 70°C

FRLSZH Fca2.83.2

9.011.0

250 1'000 -20°C to 70°C

FRLSZH Fca3.23.63.8

11.013.014.0

250 1'000 -20°C to 70°C

Cable type Construction Page Construction code ApplicationFiber count[fibers]

Loose tubes count

Loose tube nominal Ø [mm]

Jacket material

Euro classification to CPR

Nominal cable Ø [mm]

Cable weight [kg/km]

Tensile performance [N]

Crush [N/100mm]

Temperatur range in operation

Fire resistance – EN 60331-25

Page 120: Fiber Optic Cables 2018

120

R&M generates added value. Connectivity that matters.

Cable general description

Max. 4 fiber uni-tube non-metallic micro-cable for indoor or outdoor installation to micro-tubes.

Construction and dimensions

Loose tube nominal diameter 1,2 mm

Outer jacket nominal thickness 0,9 mm

Cable nominal outer diameter 3,0 mm

Cable informative weight 11 kg/km

Standard put-up length 2100/4100 m ± 5%

Outer jacket

Material UV stable FRLSZH

Jacket colour Black. Other colours available on request

Sheath marking Ink-Jet, white or black depending on the jacket colour

Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304) 1.–4.: red, green, blue, yellow

Fiber type Single- and multi-mode fibers (OS2)

Geometrical and transmission parameters are available at separate generic datasheet

Cable construction code DIN code

MT1RF xx.yy.zz.c J/A-DQ(ZN)H (2FRP 0,5)

1. Gel filled PBT loose tube with optical fibers2. FRP strength members3. FRLSZH UV stable outer jacket

Microcables MT1RF

Page 121: Fiber Optic Cables 2018

121

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1 150 N (short term) Δα ≤ 0,05 dB after test

Crush EN 60794-1-21:E3A 500 N/100mm (short term) Δα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 1 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,1 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=40 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 2 m, rotation angle ±180°, 10 cycles no damage

Kink EN 60794-1-21:E10 d = 40 x cable diameter no damage

Bend no tension EN 60794-1-21:E11A R = 40 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -20°C ÷ 70°C -30°C ÷ 70°C

Δα ≤ 0,05 dB Δα ≤ 0,15 dB, reversible

Temperature range of use

-5°C ÷ 50°C-20°C ÷ 70°C-30°C ÷ 70°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage

* EN 60794-5-10

Fire performance

Flammability - cable bundle EN 60332-3-22 (cat.A) Pass

Smoke density EN 61034-1, EN 61034-2 Pass

Halogen Free, Acid gases EN 60754-2 Pass

Euro classification to CPR EN 50575, EN 13501-6 Fca

Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count G657.A1 G657.A2

MT1RF Ø 3,0 Fca2 01.02.S7.B 01.02.S8.B

4 01.04.S7.B R851139

Order code e.g.: MT1RF 01.02.S7.B (see page 136/137) Other fiber counts and/or fiber types on special request

FTTx Constructions

Page 122: Fiber Optic Cables 2018

122

R&M generates added value. Connectivity that matters.

Cable general description

Max. 12 fiber uni-tube non-metallic flat self-supporting cable for outdoor aerial or direct buried installation.

Construction and dimensions

Loose tube nominal diameter 1,9 mm

Outer jacket nominal thickness 1,0 mm

Cable nominal outer diameter 8,0 x 4,0 mm

Cable informative weight 38 kg/km

Standard put-up length 2100/4100 m ± 5%

Outer jacket

Material UV stable HDPE

Jacket colour Black

Sheath marking Ink-Jet, white

Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304) 1.–12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink

Fiber type Single- and multi-mode fibers (OS2)

Geometrical and transmission parameters are available at separate generic datasheet

Cable construction code DIN code

ST1fH xx.yy.zz.c A-D(ZN)2YT (2FRP 2,0)

1. Gel filled PBT loose tube with optical fibers2. FRP strength members3. Rip-cord4. HDPE UV stable outer jacket

Flat self-supporting cables ST1fH

Page 123: Fiber Optic Cables 2018

123

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1 1600 N (max. allow-able tension) Δα ≤ 0,15 dB Δα ≤ 0,05 dB after test

Crush EN 60794-1-21:E3A 2000 N/100mm (long term) **4000 N/100mm (short term)**

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 10 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=150 mm, 25 cycles no damage

Torsion EN 60794-1-21:E7 L=2 m, rotation angle ±180°, 5 cycles no damage

Bend no tension EN 60794-1-21:E11A R=150 mm, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Bend under tension EN 60794-1-21:E18AL=2 m, R=150 mm, bend angle 45°, maximum allow-able tension, 20 cycles

Δα ≤ 0,05 dB after test, no damage

Maximal recommended span

TELENCO clamp ODWAC 5126 70 m (minimal mid-span sag 1 m) Δα ≤ 0,05 dB, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -20°C ÷ 70°C -30°C ÷ 70°C

Δα ≤ 0,05 dB Δα ≤ 0,15 dB, reversible

Temperature range of use

-5°C ÷ 50°C-20°C ÷ 70°C-30°C ÷ 70°C

installationoperationstorage, transport

* EN 60794-5-10, ** applied on flat side Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count G657.A1 G657.A2

ST1fH Ø 8,0 x 4,0

4 01.04.S7.B 01.04.S8.B

6 01.06.S7.B 01.06.S8.B

8 01.08.S7.B 01.08.S8.B

12 01.12.S7.B R851140

Order code e.g.: ST1fH 01.04.S7.B (see page 136/137) Other fiber counts and/or fiber types on special request

FTTx Constructions

Page 124: Fiber Optic Cables 2018

124

R&M generates added value. Connectivity that matters.

Cable general description

Max. 2 x12 fiber uni-tube non-metallic flat self-supporting cable for outdoor aerial or direct buried installation.

Construction and dimensions

Loose tube nominal diameter 1,9 mm

Outer jacket nominal thickness 1,0 mm

Cable nominal outer diameter 9,8 x 4,0 mm

Cable informative weight 59 kg/km

Standard put-up length 2100/4100 m ± 5%

Outer jacket

Material UV stable HDPE

Jacket colour Black

Sheath marking Ink-Jet, white

Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304) 1.–12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink

Loose-tube colour coding 1. red, 2. white

Fiber type Single- and multi-mode fibers (OS2)

Geometrical and transmission parameters are available at separate generic datasheet

Cable construction code DIN code

ST2fH xx.yy.zz.c A-D(ZN)2YT (2FRP 2,0)

1. Gel filled PBT loose tube with optical fibers2. FRP strength members3. Rip-cord4. HDPE UV stable outer jacket

Flat self-supporting cables ST2fH

Page 125: Fiber Optic Cables 2018

125

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1 1600 N (max. allow-able tension) Δα ≤ 0,15 dB Δα ≤ 0,05 dB after test

Crush EN 60794-1-21:E3A 2000 N/100mm (long term) **4000 N/100mm (short term)**

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 10 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=150 mm, 25 cycles no damage

Torsion EN 60794-1-21:E7 L=2 m, rotation angle ±180°, 5 cycles no damage

Bend no tension EN 60794-1-21:E11A R=150 mm, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Bend under tension EN 60794-1-21:E18AL=2 m, R=150 mm, bend angle 45°, maximum allow-able tension, 20 cycles

Δα ≤ 0,05 dB after test, no damage

Maximal recommended span

TELENCO clamp ODWAC 5126 70 m (minimal mid-span sag 1 m) Δα ≤ 0,05 dB, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -20°C ÷ 70°C -30°C ÷ 70°C

Δα ≤ 0,05 dB Δα ≤ 0,15 dB, reversible

Temperature range of use

-5°C ÷ 50°C-20°C ÷ 70°C-30°C ÷ 70°C

installationoperationstorage, transport

* EN 60794-5-10, ** applied on flat side Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count G652.D G657.A1 G657.A2

ST2fH Ø 9,8 x 4,0

2 x 6f 12f 02.06.S2.B 02.06.S7.B 02.06.S8.B

2 x 8f 16f 02.08.S2.B 02.08.S7.B 02.08.S8.B

2 x 12f 24f 02.12.S2.B 02.12.S7.B R851160

Order code e.g.: ST2fH 02.06.S2.B (see page 136/137) Other fiber counts and/or fiber types on special request

FTTx Constructions

Page 126: Fiber Optic Cables 2018

126

R&M generates added value. Connectivity that matters.

Cable general description

Max. 12 fiber non-metallic drop cable for indoor or outdoor aerial installation.

Construction and dimensions

Fiber count 1–6 8–12

Outer jacket nominal thickness (mm) 0,8 0,8

Cable nominal outer diameter (mm) 2,8 3,2

Cable informative weight (kg/km) 9 11

Standard put-up length (m) 2100/4100 ± 5% 2100/4100 ± 5%

Outer jacket

Material UV stable FRLSZH

Jacket colour Black. Other colours available on request

Sheath marking Ink-Jet, white or black depending on the jacket colour

Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304) 1.–12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink

Fiber type Bending optimized Single- and multi-mode fibers (OS2)

Geometrical and transmission parameters are available at separate generic datasheet

Cable construction code DIN code

UAF250 00.yy.zz.c J/A-(ZN)H

1. Optical fibers2. Aramid strength members3. FRLSZH UV stable outer jacket

Non-metallic drop cables UAF250

Page 127: Fiber Optic Cables 2018

127

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1 250 N (max. allow-able tension) Δα ≤ 0,15 dB Δα ≤ 0,05 dB after test

Crush EN 60794-1-21:E3A 500 N/100mm (long term)1000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 3 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=15 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L=2 m, rotation angle ±180°, 5 cycles no damage

Bend no tension EN 60794-1-21:E11A R=40 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Bend under tension EN 60794-1-21:E18AL=2 m, R=150 mm, bend angle 45°, maximum allow-able tension, 20 cycles

Δα ≤ 0,05 dB after test, no damage

Maximal recommended span

TELENCO clamp 7593

40 m (minimal sag 60 cm), maximum allow-able tension Δα ≤ 0,05 dB, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -20°C ÷ 60°C -25°C ÷ 60°C

Δα ≤ 0,05 dB Δα ≤ 0,15 dB, reversible

Temperature range of use

-5°C ÷ 50°C-20°C ÷ 60°C-25°C ÷ 60°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L=3 m,1 m water height, 24 h no water leakage

* EN 60794-3-20

Fire performance

Euro classification to CPR EN 50575, EN 13501-6 Fca

Cable expected lifetime / min. 30 years

FTTx Constructions

Order information

Construction Diameter CPR Fiber count G652.D G657.A1 G657.A2

UAF250

Ø 2,8 Fca

1 01.01.S2.B 01.01.S7.B 01.01.S8.B

2 01.02.S2.B 01.02.S7.B 01.02.S8.B

4 01.04.S2.B 01.04.S7.B 01.04.S8.B

6 01.06.S2.B 01.06.S7.B R851161

Ø 3,2 Fca8 01.08.S2.B 01.08.S7.B 01.08.S8.B

12 01.12.S2.B 01.12.S7.B R851162

Order code e.g.: UAF250 01.01.S2.B (see page 136/137) Other fiber counts and/or fiber types on special request

Page 128: Fiber Optic Cables 2018

128

R&M generates added value. Connectivity that matters.

Cable general description

Max. 12 fiber non-metallic drop cable for indoor or outdoor aerial installation.

Construction and dimensions

Fiber count 1–2 4–8 10–12

Outer jacket nominal thickness (mm) 0,8 0,8 0,8

Cable nominal outer diameter (mm) 3,2 3,6 3,8

Cable informative weight (kg/km) 11 13 14

Standard put-up length (m) 2100/4100 ± 5% 2100/4100 ± 5% 2100/4100 ± 5%

Outer jacket

Material UV stable FRLSZH

Jacket colour Black. Other colours available on request

Sheath marking Ink-Jet, white or black depending on the jacket colour

Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304) 1.–12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink

Fiber type Bending optimized Single- and multi-mode fibers (OS2)

Geometrical and transmission parameters are available at separate generic datasheet

Cable construction code DIN code

UAF1000 00.yy.zz.c J/A-(ZN)H

1. Optical fibers2. Aramid strength members3. FRLSZH UV stable outer jacket

Non-metallic drop cables UAF1000

Page 129: Fiber Optic Cables 2018

129

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1 1000 N (max. allow-able tension) Δα ≤ 0,15 dB Δα ≤ 0,05 dB after test

Crush EN 60794-1-21:E3A 500 N/100mm (long term)1000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 3 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=15 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L=2 m, rotation angle ±180°, 5 cycles no damage

Bend no tension EN 60794-1-21:E11A R=40 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Bend under tension EN 60794-1-21:E18AL=2 m, R=150 mm, bend angle 45°, maximum allow-able tension, 20 cycles

Δα ≤ 0,05 dB after test, no damage

Maximal recommended span

TELENCO clamp 7593

60 m (minimal sag 90 cm), maximum allow-able tension Δα ≤ 0,05 dB, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -20°C ÷ 60°C -25°C ÷ 60°C

Δα ≤ 0,05 dB Δα ≤ 0,15 dB, reversible

Temperature range of use

-5°C ÷ 50°C-20°C ÷ 60°C-25°C ÷ 60°C

installationoperationstorage, transport

Moisture resistance EN 60794-1-22:F5B L=3 m,1 m water height, 24 h no water leakage

* EN 60794-3-20

Fire performance

Euro classification to CPR EN 50575, EN 13501-6 Fca

Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count G652.D G657.A1 G657.A2

UAF1000

Ø 3,2 Fca1 01.01.S2.B 01.01.S7.B 01.01.S8.B

2 01.02.S2.B 01.02.S7.B R851163

Ø 3,6 Fca

4 01.04.S2.B 01.04.S7.B R851164

6 01.06.S2.B 01.06.S7.B 01.06.S8.B

8 01.08.S2.B 01.08.S7.B 01.08.S8.B

Ø 3,8 Fca 12 01.12.S2.B 01.12.S7.B R851165

Order code e.g.: UAF1000 01.01.S2.B (see page 136/137) Other fiber counts and/or fiber types on special request

FTTx Constructions

Page 130: Fiber Optic Cables 2018

130

R&M generates added value. Connectivity that matters.Sensor Cables.

Page 131: Fiber Optic Cables 2018

131

Page 132: Fiber Optic Cables 2018

132

R&M generates added value. Connectivity that matters.Cable construction code

OssWH xx.yy.zz.c

1. Gel filled stainless-steel* loose tube with optical fibers2. Stainless-steel* wire armour3. HDPE UV stable outer jacket

* AISI 304 (1.4301)

Cable general description

Thixotropic gel filled stainless-steel loose-tube (SSLT) with max. 4 optic fibers. Stainless-steel wire armour (SSWA) provides the cable with high tensile strength and crush resistance. This fully rodent resistant cable is suitable for outdoor duct or direct buried (to ground or concrete) installation and is designed to be used in wide range of applications, besides others as e.g. strain or temperature sensing cable.

Construction and dimensions

Loose tube nominal diameter 1,8 mm

Steel wire nominal diameter 0,6 mm

Outer jacket nominal thickness 0,5 mm

Cable nominal outer diameter 4,0 mm

Cable informative weight 45 kg/km

Standard put-up length 2100/4100 m ± 5%

Outer jacket

Material UV stable HDPE (FRLSZH or PA on request)

Jacket colour Black

Sheath marking Ink-Jet, white

Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request

Optical fibers

Colour coding (IEC 60304) 1.–4.: red, green, blue, yellow

Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)

Geometrical and transmission parameters are available at separate generic datasheet

Sensor CablesOssWH

Page 133: Fiber Optic Cables 2018

133

Mechanical characteristics

Test Test method Value Acceptance criteria*

Tensile performance EN 60794-1-21:E1 1000 N (long term) 2000 N (short term)

Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test

Crush EN 60794-1-21:E3A 4000 N/100mm (long term)8000 N/100mm (short term)

Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage

Impact EN 60794-1-21:E4 20 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage

Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage

Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage

Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage

Environmental characteristics

Test Test method Value Acceptance criteria*

Temperature cycling EN 60794-1-22:F1 -40°C ÷ 80°C-40°C ÷ 80°C

Δα ≤ 0,05 dB Δα ≤ 0,15 dB, reversible

Temperature range of use

-10°C ÷ 50°C-40°C ÷ 80°C-40°C ÷ 80°C-50°C ÷ 150°C

installationoperationstorage, transportshort term max. 60 min

* EN 60794-3-10, EN 60794-3-11 Cable expected lifetime / min. 30 years

Order information

Construction Diameter CPR Fiber count OM3 OM4 G652.D

OssWH Ø 4,0

1 01.01.M3.B 01.01.M4.B 01.01.S2.B

2 01.02.M3.B 01.02.M4.B 01.02.S2.B

4 01.04.M3.B 01.04.M4.B R851166

Order code e.g.: OssWH 01.01.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request

Sensor Cables

Page 134: Fiber Optic Cables 2018

134

R&M generates added value. Connectivity that matters.Explanations.

Page 135: Fiber Optic Cables 2018

135

Fiber specifications.

Geometrical and Transmission ParametersFiber typeto ITU-T recom.:

OS2 (9/125)G.652.D

OS2 (9/125)A

G.657.A19/125

G.655.D9/125

G.655.E, G.656

Fiber Nomenclature S2 S7 S5 S6

Mode Field Diameter (μm) - typically@1310 nm@1550 nm

9.2 ± 0.410.4 ± 0.5 8.4 ± 0.6 8.6 ± 0.4

Cladding Diameter (μm) 125 ± 0.7

Coating Diameter (μm) 242 ± 7

Attenuation 8 (dB/km)typical / max. (single fiber) @ 1310 nmtypical / max. (single fiber) @ 1550 nmtypical / max. (single fiber) @ 1625 nm

0.31 / 0.360.20 / 0.250.21 / 0.27

0.25 / 0.300.27 / 0.34

Fiber typeOM1

(62,5/125)OM2

(50/125)A

OM3 (50/125)A

OM4 (50/125)A

OM5 (50/125)A

Fiber Nomenclature M1 M2 M3 M4 M5

Numerical Aperture (μm) 0.275 ± 0.01562.5 ± 2.5

0.200 ± 0.01550.0 ± 2.5Core Diameter (μm)

Cladding Diameter (μm) 125 ± 1.0

Coating Diameter (μm) 242 ± 5

Overfilled Modal Bandwidth (Mhz.km)@850 nm@ 1300 nm

_˃ 200_˃ 500

_˃ 500_˃ 500

_˃ 1500_˃ 500

_˃ 3500_˃ 500

Link Length (m)lGb/sl0Gb/s

<_ 220<_ 33

<_ 550<_ 82

<_ 1000<_ 300

<_ 1100<_ 550

Attenuation 8 (dB/km)typical / max. (single fiber) @ 850 nmtypical / max. (single fiber) @ 1300 nm

2.7 / 3.30.6 / 1.1

2.5 / 3.50.6 / 1.5

Page 136: Fiber Optic Cables 2018

136

R&M generates added value. Connectivity that matters.DIN/VDE 0888 cable coding.

Application area

A outdoor cable AT divideable outdoor cable B loose tube jellyfree D loose tube with jelly F fiber H reinforced tube, empty J indoor cable U universal cable (for indoor and outdoor) V tight tube W reinforced tube, filled

Tube type

B loose tube, jelly free D loose tube, jelly filled H reinforced tube, jelly free V tight tube W reinforced tube, jelly filled

Cable construction

B reinforcement, armor F core filled Q dry and longitudinal watertight (ZN) non-metallic strain-relief (ZS) strain-relief with steel (SR) overlapping corrugated steel tape

Jacket material

H halogen free jacket (FRLSZH) Y PVC, polyvinylchloride 2Y PE, polyethylen (LDPE; HDPE) 4Y PA, polyamide 11Y PUR, polyurethane

Quantity of fiber resp. fiber bundling

n amount of fiber nxm amount of loose tube × amount of fiber per tube

Fiber type

E single-mode fiber (glass core/glass jacket) G multimode, graded index fiber (glass core/glass jacket) GK multimode, graded index fiber – PCF (glass core/plastic jacket) K multimode, step index fiber – PCF (glass core/plastic jacket) P plastic fiber – POF (plastic core/plastic jacket) S multimode step index fiber (glass core/glass jacket)

Core diameter

n diameter in μm e.g. 9, 50, 62.5, 200

Cladding diameter

n diameter in μm e.g. 125, 230

Attenuation

xx attenuation at wave length in dB/km

Wave length

A at 650 nm B at 850 nm F at 1300 nm (MM) F at 1310 nm (SM) H at 1550 nm

Bandwidth

yy MHz × 100 m bandwidth with POF fibers at 650 nm yy MHz × km bandwidth with MM fibers yy ps/(nm × km) dispersion with SM fibers

DIN VDE V 0888: 2018-02

Page 137: Fiber Optic Cables 2018

137

Color code for fibers IEC 60304 – R&M Standard

Color code for fibers ANSI/TIA-598

Loose-tube color coding

Outer jacket color

Color codes.

1 2 3 4 5 6 7 8 9 10 11 12

blue orange green brown gray white red black yellow violet pink turquoise

13 14 15 16 17 18 19 20 21 22 23 24

bluering-marked

orangering-marked

greenring-marked

brownring-marked

grayring-marked

whitering-marked

redring-marked

transparentring-marked

yellowring-marked

violetring-marked

pinkring-marked

turquoisering-marked

1 2 3 4 5 18 filler filler

6–17...

red green white white white white black uncolored

1 2 3 4 5 6 7 8 9 10 11 12

red green blue yellow white gray brown violet turquoise black orange pink

13 14 15 16 17 18 19 20 21 22 23 24

redring-marked

greenring-marked

bluering-marked

yellowring-marked

whitering-marked

grayring-marked

brownring-marked

violetring-marked

turquoisering-marked

transparentring-marked

orangering-marked

pinkring-marked

B R G B Y W I G B V T O P

blackstandard

red green blue yellow white ivory gray brown violet turquoise orange pink

Page 138: Fiber Optic Cables 2018

138

R&M generates added value. Connectivity that matters.

Cable construction partWay of installation

I indoor O outdoor U universal S ADSS (All Dielectric Self-Supporting) K Fig.8 (self-supporting with steel rope messenger) Q fire-resistant to EN60331-25 M mini/micro-cable (for blowing to micro-duct)

Buffer type

B 900μm tight buffer T gel filled PBT loose-tube (with up to 12 fibers) X gel filled PBT loose-tube (with up to 24 fibers) t flexible loose-tube (with up to 12 fibers) x flexible loose-tube s stainless-steel loose-tube

Buffer count & diameter in mm e.g. 6x2,3

1 unitube (LT) or simplex construction (TB) 2 2 loose-tubes (flat LT cable) or duplex construction (TB) 3 12 loose-tubes or tight-buffers 4 number of loose-tubes or tight-buffers 5 number of loose-tubes or tight-buffers 6 number of loose-tubes or tight-buffers 8 number of loose-tubes or tight-buffers 7 16(5+11) loose-tubes or tight-buffers (in two layers) 9 18(6+12) loose-tubes or tight-buffers (in two layers) 0 24(9+15) loose-tubes or tight-buffers (in two layers)

Water-blocking

J jelly filled cable core

Strength member(s) in/under sheath

A aramid yarns E e-glass yarns (standard rodent protection) G e-glass yarns (impoved rodent protection) R 2 FRP rods integrated in the outer sheath D 2 steel wires integrated in the outer sheath f 2 FRP rods under the outer sheath - flat construction

Armour

C corrugated steel tape armour (CSTA) W steel wire armour (SWA) P fiber reinforced plastic rod armour (FRPA) Z laminated aluminium tape under sheath

Sheath material

F FRLSZH (fire-retardant, low-smoke, zero-halogen) H HDPE (high-density polyethylene) L LDPE (low-density polyethylene) N PA (polyamide) Y PVC (polyvinylchloride) V PUR (polyurethane)

Coding of FOC constructions.

Page 139: Fiber Optic Cables 2018

Fiber count & type partxx.yy.zz.c

xx number of tubes containing fibers yy fiber count per each of tubes zz fiber type c sheath colour

e.g. MT1H 01.04.M3.B

SM (single-mode, S) = zz

S2 G.652.D S5 G.655 S6 G.656 S7 G.657.A1 S8 G.657.A2/B2 S9 G.657.A3/B3

MM (multi-mode, M) = zz

M1 OM1 (BW 200/500 Mhz.km) M2 OM2 (BW 500/500 Mhz.km) M3 OM3 (BW 1500/500 Mhz.km) M4 OM4 (BW 3500/500 mhz.km) M5 OM5 (to be specified) M6 OM2+ (BW 600/1200 Mhz.km)

Outer sheath colour = c B black R red E green U blue Y yellow W white I ivory G grey N brown V violet T turquoise O orange P pink

030.5914

Page 140: Fiber Optic Cables 2018

140

R&M generates added value. Connectivity that matters.

Construction Products Regulation. Euro class B2ca and class CcaProducts with very high or high fire protection, no continuous flame propagation, limited fire development, and a limited heat release rate.

Euro class DcaProducts with medium fire protection, continuous flame propagation, moderate fire development, and a limited heat release rate.

Euro class Eca Products with normal fire protection, exposure to a small flame may ignite the cable, low resistance to temperature increases.

Additional classification

Production/density of smokeThere are three classes for smoke production and density in cables: s1 weak smoke production s2 moderate smoke production s3 potentially strong smoke production

Euro classification (ca) Classification criteria Additional criteria

Assessing and examining the consistency of theperformance system

A EN ISO 1716Gross heat of combustion 1+

Verification documents:Type testing

Regular works auditRegular sampling of ongoing production

B1

EN 50399Heat release

Flame propagation

EN 60332-1-2Flame propagation

Smoke production(s1a, s1b, s2, s3)

EN 50399 / EN 61034-2

Acidity(a1, a2, a3)

EN 50267-2-3

Flaming droplets(d0, d1, d2)EN 50399

B2

C

D 3Verification documents:

Type testing

E EN 60332-1-2Flame propagation

F 4No verification documents

CPR.

Page 141: Fiber Optic Cables 2018

141

Acid production/corrosivityThere are three classifications of corrosivity: a1 slightly corrosive fumes a2 moderately corrosive fumes a3 potentially highly corrosive fumes

Flaming dropletsThere are three classes for the production of flaming droplets: d0 no flaming droplets d1 flaming droplets for a short time d2 potentially long-lasting flaming droplets

Recommendations for the future use of EU fire protection classification

First and foremost, the CPR enables a comparison between the fire protection properties of different products. However, every member state is instructed and required to define the minimum necessary fire protection classification for the various applications themselves. The requirements placed on products can thus differ greatly across Europe for each building type. Therefore, the planner must check and comply with the local regulations. Various organizations and international associations have also declared their own recommendations, which sometimes go well beyond the legal minimum requirements. In consideration of cost vs. benefit, R&M makes the following recommendation:

Euro classification Additional classification Fire protection level of the installation cables

(Use recommendations from R&M)*Flame propagationHeat production

Smoke production/density

Acid production/corrosivity

Flaming droplets

Aca NA

B1ca NA

B2ca s1 a1 d1Very high

(e.g. escape routes, tunnels, high-risk industries)

Cca s1 a1 d1High

(e.g. hospitals, nursing homes, schools)

Dca s2 a2 d1Medium

(e.g. public buildings, hotels, airports, industrial environments)

EcaNormal

(e.g. normal office buildings, residential premises)

FcaLow

(not recommended)

* The necessary fire protection classification for installation cables is prescribed by the relevant fire prevention authority.

Page 142: Fiber Optic Cables 2018

142

Global network The worldwide network of proprietary companies and certified partners creates the basis for the greatest possible customer proximity. Products and solutions from Reichle & De-Massari are available locally in more than 100 countries. The company's branches in Europe, Asia Pacific, the Middle East, North and Latin America together with partners guarantee that the sales/distribution, installation and maintenance of R&M solutions around the globe take place quickly and that local customer requirements are satisfied.

R&M supports projects from start to finish, i.e. from the planning of the networks, via installation, through to ongoing operation. Personal service and numerous satisfied customers worldwide. We give you the security of knowing you are working with the right partner!

R&M Headquarters R&M Manufacturing R&M Sales Offices

R&M – worldwide. From project planning to operation.

Page 143: Fiber Optic Cables 2018

143

«R&M gave us excellent support during the project. The contact partners were always reachable. Everything we needed was delivered promptly.» Marco Thieme, graduate engineer and project manager at the Stuttgart-based engineering firm Schwarz, Sparkassen Academy in Stuttgart

Success stories

Together with our customers, we are constantly developing meaningful success stories that give valuable insight into the complex world of connectivity. A number of publications from all over the world and from various sectors and industries bear witness to R&M's partnership-based collaboration with its business partners. Manufacturers, partners and end customers all benefit from the content and diversified publication of the success stories.

Seminars, training and workshops

R&M regularly offers practice-oriented seminars, training sessions and workshops worldwide. Field reports and customer contributions illustrate the successful implementation of our products and solutions.

Warranty program

R&M pursues an uncompromising quality policy that encompasses everything from compo-nents to the running operation of the installations. R&M offers one of the most complete warranty programs in the structured cabling industry based on EN 50173-x, ISO/IEC 11801 and ANSI with 25-year warranty and life-long application guarantee.

Qualified Partner Program

R&M supports and promotes specialists in network technology and structured building cabling all over the world with its Qualified Partner Program. The partners qualified and certified by R&M thus guarantee identical, top quality standards worldwide.

Page 144: Fiber Optic Cables 2018

We are represented by more than 100 qualified partners worldwide. Find your local partner at: www.rdm.com

Switzerland – Headquarters

Reichle & De-Massari AGwww.rdm.com

Czech Republic

Reichle & De-Massari Czech Republic a.s.www.rdm-czech.com

R&M

_FO

-Cab

les_

2018

_08.

18_E

N/0

8.18

© R

eich

le &

De-

Mas

sari

AG –

All

right

s re

serv

ed

Europe

AUSTRIAReichle & De-Massari Austria GmbH

BELGIUMReichle & De-Massari Benelux Sales Office

BULGARIAReichle & De-Massari EOOD

CZECH REPUBLIC Reichle & De-Massari Czech Republic a.s.

FRANCEReichle & De-Massari France Sàrl

GERMANYReichle & De-Massari GmbH

HUNGARYReichle & De-Massari (Mo.) Kft

ITALYReichle & De-Massari Italia Srl

NETHERLANDSReichle & De-Massari Netherlands B.V.

NORDICSReichle & De-Massari Nordics Sales Office

POLANDReichle & De-Massari Polska Sp. z o.o.

PORTUGALReichle & De-Massari Portugal Sales Office

ROMANIAReichle & De-Massari Romania Sales Office

RUSSIAN FEDERATIONReichle & De-Massari Russia Sales Office

SERBIA Reichle & De-Massari Serbia Sales Office

SLOVAKIA Reichle & De-Massari Slovakia Sales Office

SLOVENIA Reichle & De-Massari Slovenia Sales Office

SPAINReichle & De-Massari Iberia SL

SWITZERLANDReichle & De-Massari AG, Sales Office

UNITED KINGDOMReichle & De-Massari (UK) Ltd

North America

UNITED STATESR&M USA Inc.

Latin America

BRASILReichle & De-Massari Brasil Ltda

COLOMBIAReichle & De-Massari Colombia Sales Office

Asia Pacific

AUSTRALIA & NEW ZEALANDReichle & De-Massari Australia Pty Ltd

GREATER CHINA GROUPReichle & De-Massari China Co. Ltd.

INDIAR&M India Pvt Ltd

INDONESIAReichle & De-Massari Indonesia Sales Office

JAPANR&M Japan K.K.

MALAYSIAReichle & De-Massari Malaysia Sales Office

SINGAPOREReichle & De-Massari Far East (Pte) Ltd

Middle East, Turkey & Africa

EGYPTReichle & De-Massari Egypt Sales Office

JORDANReichle & De-Massari Jordan Sales Office

KENYAReichle & De-Massari Kenya Sales Office

KUWAIT Reichle & De-Massari Kuwait Sales Office

MOROCCOReichle & De-Massari Maroc Sàrl

OMAN Reichle & De-Massari Oman Sales Office

QATARReichle & De-Massari Qatar Sales Office

SAUDI ARABIAReichle & De-Massari Saudi Arabia Ltd

TURKEYReichle & De-Massari Elektronik Sanayi VE Ticaret Ltd Sirketi

UNITED ARAB EMIRATESReichle & De-Massari MEA FZE