FIBER OPTIC CABLEhscnci.com/.../2019/06/hyesung_fiber_optic_cable_2018.pdf · 2019-06-11 · Micro...

20
FIBER OPTIC CABLE PRODUCT CATALOGUE

Transcript of FIBER OPTIC CABLEhscnci.com/.../2019/06/hyesung_fiber_optic_cable_2018.pdf · 2019-06-11 · Micro...

Page 1: FIBER OPTIC CABLEhscnci.com/.../2019/06/hyesung_fiber_optic_cable_2018.pdf · 2019-06-11 · Micro duct installation Installed in air blown method-----Feature Standard fiber count:

FIBER OPTICCABLEPRODUCT CATALOGUE

Page 2: FIBER OPTIC CABLEhscnci.com/.../2019/06/hyesung_fiber_optic_cable_2018.pdf · 2019-06-11 · Micro duct installation Installed in air blown method-----Feature Standard fiber count:

We serve you the best.

We satisfy you the best.

Page 3: FIBER OPTIC CABLEhscnci.com/.../2019/06/hyesung_fiber_optic_cable_2018.pdf · 2019-06-11 · Micro duct installation Installed in air blown method-----Feature Standard fiber count:

Communication CableTechnology know-howAccumulated since 1991

Since established in 1991, HYESUNG Cable & Communication INC., has specialized

in manufacturing and supplying communication cables. We never stop researching,

designing, developing, and manufacturing products with the higher level of quality

to address the ever-changing demands in everyday life as well as the industry.

Our commitment to develop and deliver solutions to address our customers’ needs

and challenges keep our technology on the cutting edge and our know-how in the

field more valuable, which our customers highly appreciate.

HY

ES

UN

G C

AB

LE &

CO

MM

UN

ICA

TIO

N

03

Page 4: FIBER OPTIC CABLEhscnci.com/.../2019/06/hyesung_fiber_optic_cable_2018.pdf · 2019-06-11 · Micro duct installation Installed in air blown method-----Feature Standard fiber count:

Optical Fiber

Inner Jelly

Loose Tube

Jelly Compound

Central Strength Member

Core Wrapping Tape

Dielectric Strength Member

Rip Cord

Laminated Al Tape

Outer PE Sheath

LOO

SE

TU

BE

CA

BLE

04

01

02

03

04

05

06

07

08

09

10

Loose Tube Cable01LAP TAPE

Applications

Construction

Local area networkLong haul communication systemSubscriber network systemJunction communication systemInter building & communication link

-----

-----

Feature

Standard fiber count: 2-288 coreLight weight & flexibilityDistinguishable by color of fiber & loose tubeHigh tensile strength designUV-resistant outer jacket

Fiber Count No. of Tube No. of Fibers per Tube Outer Diameter(mm) Weight (km/kg)

2 - 36 1 - 6 1 - 6 11.5 125

38 - 72 1 - 6 1 - 12 12.0 140

74 - 96 7 - 8 1 - 12 14.0 185

98 - 120 9 - 10 1 - 12 15.5 200

122 - 144 11 - 12 1 - 12 17.0 280

146 - 288 13 - 24 1 - 12 20.5 370

Specifications

Characteristics Specifications

Max. Tensile Load 2700N - 4000N

Crush Resistance 200N/cm

Bending RadiusInstallation 20 times of cable OD

Operation 10 times of cable OD

Temperature RangeInstallation -30℃ - + 60℃

Operation -40℃ - + 70℃

Mechanical & environmental Characteristics

01

02

04

05

0306

07

08

09

10

Page 5: FIBER OPTIC CABLEhscnci.com/.../2019/06/hyesung_fiber_optic_cable_2018.pdf · 2019-06-11 · Micro duct installation Installed in air blown method-----Feature Standard fiber count:

Loose Tube CableLAP, Self-supporting

02

Messenger Wire

Optical Fiber

Inner Jelly

Loose Tube

Jelly Compound

Central Strength Member

Core Wrapping Tape

Rip Cord

Laminated Al Tape

Outer PE Sheath

01

02

03

04

05

06

07

08

09

10

LOO

SE

TU

BE

CA

BLE

05

Fiber Count No. of Tube No. of Fibers per Tube Outer Diameter(mm) Weight (km/kg)

2 - 36 1 - 6 1 - 6 11.5 x 23.5 210

38 - 72 1 - 6 1 - 12 12.0 x 24.0 230

74 - 96 7 - 8 1 - 12 14.0 x 26.0 280

98 - 120 9 - 10 1 - 12 15.5 x 27.5 325

122 - 144 11 - 12 1 - 12 17.0 x 29.0 325

146 - 288 13 - 24 1 - 12 20.5 x 32.5 490

Specifications

Characteristics Specifications

Max. Tensile Load 2700N - 4000N

Crush Resistance 200N/cm

Bending RadiusInstallation 20 times of cable OD

Operation 10 times of cable OD

Temperature RangeInstallation -30℃ - + 60℃

Operation -40℃ - + 70℃

Mechanical & environmental Characteristics

Applications

Local area networkLong haul communication systemJunction communication systemSubscriber network system

-----

----

Feature

Standard fiber count: 2-288 coreLight weight & flexibilityDecrease in installation costHigh tensile strength designUV-resistant outer jacket

Construction

01

02

04

05

03

0607

08

09

10

Page 6: FIBER OPTIC CABLEhscnci.com/.../2019/06/hyesung_fiber_optic_cable_2018.pdf · 2019-06-11 · Micro duct installation Installed in air blown method-----Feature Standard fiber count:

Optical Fiber

Inner Jelly

Loose Tube

Filler

Central Strength Member

Water Blocking Yarn

Water Blocking Tape

Rip Cord

Strength Member

Outer Sheath

AD

SS

CA

BLE

06

01

02

03

04

05

06

07

08

09

10

ADSS Cable03All Dielectric Self-Supporting cable, Single Jacket

Applications

Construction

Low-voltage transmission and distribution systemRailways and Telecommunications pole routeSuitable for all type of aerial lines

-----

---

Feature

Standard fiber count: 2-144 coreProtection from lightning and electrical interferenceUV-resistant outer jacket & Water blocked cableHigh tensile strength & long term reliabilityStable and highly reliable transmission parameters

Fiber Count No. of Tube No. of Fibers per Tube Outer Diameter(mm) Weight (km/kg)

2 - 12 1 1 - 12

24 2 12 11.3 96

36 3 12

48 4 12

72 6 1212.0 105

96 8 12

12 12

15.6 180

17.2 215144

Specifications

Characteristics Specifications

SPAN 100m

Max. Tensile Load 2700N

Crush ResistanceShort Term 220N/cm

Long Term 110N/cm

Bending RadiusInstallation 20 times of cable OD

Operation 10 times of cable OD

Temperature RangeInstallation -30℃ - + 60℃

Operation -40℃ - + 70℃

Mechanical & environmental Characteristics

01

02

0405

03

0607

08

09

10

Page 7: FIBER OPTIC CABLEhscnci.com/.../2019/06/hyesung_fiber_optic_cable_2018.pdf · 2019-06-11 · Micro duct installation Installed in air blown method-----Feature Standard fiber count:

ADSS CableAll Dielectric Self-Supporting cable, Double Jacket

04

Optical Fiber

Inner Jelly

Loose Tube

Filler

Central Strength Member

Water Blocking Yarn

Water Blocking Tape

Rip Cord

Strength Member

Inner Sheath

01

02

03

04

05

06

07

08

09

10

Outer Sheath11

AD

SS

CA

BLE

07

Applications

Low-voltage transmission and distribution systemRailways and Telecommunications pole routeSuitable for all type of aerial lines

-----

---

Feature

Standard fiber count: 2 - 288 coreProtection from lightning and electrical interferenceUV-resistant outer jacket & Water blocked cableHigh tensile strength & long term reliabilityStable and highly reliable transmission parameters

Fiber Count No. of Tube No. of Fibers per Tube Outer Diameter(mm) Weight (km/kg)

6 1 1 - 12

12 1 12 12.8 125

24 2 12

36 3 12

48 4 12

72 6 12

8 12

13.3 135

14.6 16096

12 12 17.5 230144

18 12 18.4 245216

24 12 20.4 300288

Specifications

Characteristics Specifications

SPAN 200m - 400m

Max. Tensile Load 2700N

Crush ResistanceShort Term 220N/cm

Long Term 110N/cm

Bending RadiusInstallation 20 times of cable OD

Operation 10 times of cable OD

Temperature RangeInstallation -30℃ - + 60℃

Operation -40℃ - + 70℃

Mechanical & environmental Characteristics

Construction

01

02

04

05

03

06 07

08

0910

11

Page 8: FIBER OPTIC CABLEhscnci.com/.../2019/06/hyesung_fiber_optic_cable_2018.pdf · 2019-06-11 · Micro duct installation Installed in air blown method-----Feature Standard fiber count:

Central Strength Member

Optical Fiber

Inner Jelly

Loose Tube

Water Blocking Yarn

Water Blocking Tape (If necessary)

Rip Cord

Outer Jacket

MIC

RO

CA

BLE

08

01

02

03

04

05

06

07

08

Micro Cable05

Applications

Construction

Local area networkSubscriber network systemFiber to the home(FTTH)Micro duct installation

----

----

Feature

Standard fiber count: 2-288 coreCompact designHigh tensile strength & flexibilityExcellent optical transmission & physical performance

Fiber Count No. of Tube No. of Fibers per Tube Outer Diameter(mm) Weight (km/kg)

2 - 12 1 1 - 12

24 2 125.6

48 4 12

72 6 12

22.4

24

24.5

26

96 8 12 6.4 36

144 12 12

24 12

8.4 68

9.6 80288

Specifications

Characteristics Specifications

Max. Tensile Load 1000N

Crush Resistance 100N/cm

Bending RadiusInstallation 20 times of cable OD

Operation 10 times of cable OD

Temperature RangeInstallation -30℃ - + 60℃

Operation -40℃ - + 70℃

Mechanical & environmental Characteristics

01

02

0405 03

06

07

08

Page 9: FIBER OPTIC CABLEhscnci.com/.../2019/06/hyesung_fiber_optic_cable_2018.pdf · 2019-06-11 · Micro duct installation Installed in air blown method-----Feature Standard fiber count:

Air Blown Cable 06

Central Strength Member

Optical Fiber

Inner Jelly

Loose Tube

Water Blocking Yarns

P/S Tape

Rip Cord

Outer Sheath

01

02

03

04

05

06

07

08

AIR

BLO

WN

CA

BLE

09

Applications

Local area networkSubscriber network systemFiber to the home(FTTH)Micro duct installationInstalled in air blown method

----

-----

Feature

Standard fiber count: 2-72 coreCompact designHigh tensile strength & flexibilityExcellent optical transmission & physical performance

Construction

Fiber Count No. of Tube No. of Fibers per Tube Outer Diameter(mm) Weight (km/kg)

2 - 12 1 1 - 12

24 2 12

48 4 125.8 34

72 6 12

Specifications

Characteristics Specifications

Max. Tensile Load 1000N

Crush Resistance 100N/cm

Bending RadiusInstallation 20 times of cable OD

Operation 10 times of cable OD

Temperature RangeInstallation -30℃ - + 60℃

Operation -40℃ - + 70℃

Mechanical & environmental Characteristics

01

02

0405 03

06

07

08

Page 10: FIBER OPTIC CABLEhscnci.com/.../2019/06/hyesung_fiber_optic_cable_2018.pdf · 2019-06-11 · Micro duct installation Installed in air blown method-----Feature Standard fiber count:

Optical Fiber

Tight Buffer

Strength Member

Outer Sheath

Strength Member

Notch to Pick Fiber

Optical Fiber

Outer Sheath

OP

TIC

AL D

RO

P C

AB

LE

10

01

02

03

04

05

06

07

08

Optical Drop Cable07

Applications

Construction

Fiber to the home(FTTH)Cyber APTOffice BuildingPC roomCATV

---

-----

Feature

Standard fiber count: 1, 2, 4 coreHigh flexibility and light weight for easy handlingEasy stripping for quick splicing

Type Fiber Count Buffer Diameter (㎛) Outer Diameter(mm) Weight (km/kg)

Round 1 - 4 900

Flat 1 - 4 -

3.0

2.0 x 3.0 / 2.0 x 1.6

8.6

12

Specifications

Characteristics Specifications

Max. Tensile Load Round 500N - 1,000N Flat 300N

Crush Resistance 100N/cm

Bending RadiusInstallation 20 times of cable OD

Operation 10 times of cable OD

Temperature RangeInstallation -30℃ - + 60℃

Operation -40℃ - + 70℃

Mechanical & environmental Characteristics

Round/Flat type

01

02

04

05

03

0607

08

Page 11: FIBER OPTIC CABLEhscnci.com/.../2019/06/hyesung_fiber_optic_cable_2018.pdf · 2019-06-11 · Micro duct installation Installed in air blown method-----Feature Standard fiber count:

Optical Drop Cable 08

Optical Fiber

Tight Buffer

Strength Member

Outer Sheath

Messenger Wire

Optical Fiber

Strength Member

Messenger Wire

01

02

03

04

05

06

07

08

Outer Sheath09

OP

TIC

AL D

RO

P C

AB

LE

11

Applications

Fiber to the home(FTTH)Cyber APTOffice BuildingPC roomCATV

---

-----

Feature

Standard fiber count: 2-4 coreEconomical construction for aerial cabling applicationOutstanding mechanical & environmental characteristics

Type Fiber Count Buffer Diameter (㎛) Outer Diameter(mm) Weight (km/kg)

Round 1 - 4 900

Flat 1 - 2 -

3.8 x 6.5

2.0 x 5.2

21

23

Specifications

Construction

Characteristics Specifications

Max. Tensile Load Round 1,400N Flat 1,000N

Crush Resistance 200N/cm

Bending RadiusInstallation 20 times of cable OD

Operation 10 times of cable OD

Temperature RangeInstallation -30℃ - + 60℃

Operation -40℃ - + 70℃

Mechanical & environmental Characteristics

F-8 Round/Flat type

05

04

02

01

03

08

07

09

06

Page 12: FIBER OPTIC CABLEhscnci.com/.../2019/06/hyesung_fiber_optic_cable_2018.pdf · 2019-06-11 · Micro duct installation Installed in air blown method-----Feature Standard fiber count:

Optical Fiber

Tight Buffer

Strength Member

Rip cord

Outer Sheath

DIS

TR

IBU

TIO

N C

AB

LE

12

01

02

03

04

05

Distribution Cable09

Applications

Construction

FTTXIndoor or outdoor applicationBackbone & computer room cabling

----

---

Feature

Standard fiber count: 2-48 coreSmall size & light weight for limited conduit spaceRugged & high performanceLSZH, OFNR, OFNP rated

Construction Fiber Count Outer Diameter(mm) Weight (km/kg)

Single Unit

2

4

4.5

5.3

20

25

6 5.7 30

8 6.0 35

12 6.7 40

16 8.5 70

18 8.9 75

24 9.8 90

6 Fiber Subunits 24 13.9 160

12 Fiber Subunits 48 18.3 275

Specifications

Characteristics Specifications

Max. Tensile Load 600N - 1,200N

Crush Resistance 50 - 100N/cm

Bending RadiusInstallation 20 times of cable OD

Operation 10 times of cable OD

Temperature RangeInstallation -10℃ - + 70℃

Operation -20℃ - + 70℃

Mechanical & environmental Characteristics

Tight Buffered Cable

01 02

04

05

03

Page 13: FIBER OPTIC CABLEhscnci.com/.../2019/06/hyesung_fiber_optic_cable_2018.pdf · 2019-06-11 · Micro duct installation Installed in air blown method-----Feature Standard fiber count:

Interlocking Armored Cable 10

Optical Fiber

Tight Buffer

Strength Member

Rip Cord

Inner Sheath

Interlocking Armored

Outer Sheath

01

02

03

04

05

06

07

INT

ER

LOC

KIN

G A

RM

OR

ED

CA

BLE

13

Applications

Local area networksCritical data linesCommercial construction or renovationsHeavy industry(mining, pulp, petro-chemical, etc)High security areas

-----

-----

Feature

Standard fiber count: 2-24 coreHigh protection against damages due to extreme conditionsElimination of the need for conventional conduit or inner ductReducing time & cost for installationOFCP rated

Construction Fiber Count Weight (km/kg)

Single Unit

6 Fiber Subunits

2

4 12.0

135

140

6 145

8 165

1213.3

170

16 200

2417.5

215

24 21.6

Inner Cable OD (mm) Armored cable OD (mm)

4.5

5.3

5.7

6.0

6.7

8.5

9.8

13.9 330

Specifications

Construction

Characteristics Specifications

Max. Tensile Load 600 - N1,200N

Crush Resistance 50 - 100N/cm

Bending RadiusInstallation 20 times of cable OD

Operation 10 times of cable OD

Temperature RangeInstallation -30℃ - + 60℃

Operation -40℃ - + 70℃

Mechanical & environmental Characteristics

01 02

05

04

03

06

07

Page 14: FIBER OPTIC CABLEhscnci.com/.../2019/06/hyesung_fiber_optic_cable_2018.pdf · 2019-06-11 · Micro duct installation Installed in air blown method-----Feature Standard fiber count:

Optical Fiber

Tight Buffer

Strength Member

Inner Sheath

Central Strength Member

Strength Member

Outer Sheath

BR

EA

KO

UT

CA

BLE

14

01

02

03

04

05

06

07

Breakout Cable11

Applications

Construction

Local area networksIndoor or outdoor applicationDistribution applicationMultiple locations such as wiring racks and closetsBackbone & computer room cabling

----

-----

Feature

Standard fiber count: 2-12 coreGreat flexibility and mechanical protection of the optical fibersRugged & high performanceLSZH, OFNR, OFNP rated

Characteristics Specifications

Max. Tensile Load 600N - 1,200N

Crush Resistance 35N/cm

Bending RadiusInstallation 20 times of cable OD

Operation 10 times of cable OD

Temperature RangeInstallation -10℃ - + 70℃

Operation -20℃ - + 70℃

Mechanical & environmental Characteristics

Fiber Count Buffer Diameter (㎛) Subunit OD (mm) Outer Diameter(mm) Weight (km/kg)

2

4

7.5

7.7

50

55

6 900 2.0 8.0 65

8 9.5 85

12 10.5 95

Specifications

0102

05

04

03

06

07

Page 15: FIBER OPTIC CABLEhscnci.com/.../2019/06/hyesung_fiber_optic_cable_2018.pdf · 2019-06-11 · Micro duct installation Installed in air blown method-----Feature Standard fiber count:

Simplex and Duplex Cord 12

Optical Fiber

Tight Buffer

Strength Member

Outer Sheath

01

02

03

04

SIM

PLE

X A

ND

DU

PLE

X C

OR

D

15

Applications

Local area networksCritical data linesCommercial construction or renovationsHeavy industry(mining, pulp, petro-chemical, etc)High security areas

-----

-----

Feature

Standard fiber count: 2-24 coreHigh protection against damages due to extreme conditionsElimination of the need for conventional conduit or inner ductReducing time & cost for installationOFCP rated

Construction

Characteristics Specifications

Max. Tensile Load 200N - 500N

Crush Resistance 3.5N/cm

Bending RadiusInstallation 20 times of cable OD

Operation 10 times of cable OD

Temperature RangeInstallation -10℃ - + 70℃

Operation -20℃ - + 70℃

Mechanical & environmental Characteristics

Construction Buffer Diameter (m) Weight (km/kg)

6003.0

4.0

4.0

900 6.5

9.5

18.0900

Simplex

Duplex28.0

Outer Diameter (mm)

1.6

1.8

2.0

2.4

2.9

2.0

2.8

Specifications

01

01

02

02

04

04

0303

Page 16: FIBER OPTIC CABLEhscnci.com/.../2019/06/hyesung_fiber_optic_cable_2018.pdf · 2019-06-11 · Micro duct installation Installed in air blown method-----Feature Standard fiber count:

Fiber

Tight Buffered

Optical sheath(LSZH)

Copper

PE Insulation

Polyester tape

Outer sheath(LSZH)

HY

BR

ID C

AB

LE

16

01

02

03

04

05

06

07

Hybrid Cable13

Applications

Construction

Optical network termination to LAN or telephone networkSecurity networksIP enable appliancesWireless access points

---

----

Feature

High speedEasy and less expensive installationCopper and optic fiber links

Characteristics Specifications

Bending RadiusInstallation 15 times of cable OD

Operation 10 times of cable OD

Temperature RangeInstallation -15℃ - + 55℃

Operation -30℃ - + 70℃

Mechanical & environmental Characteristics

Optical fiber + Cat. 5E

Cat 5E (4P)

Copper wire Diameter

Insulation Diameter

0.50mm

0.9mm

Optic Unit (G657A2 2F)

Buffer Diameter

Sheath Diameter

900 ㎛

2.5mm

Outer Sheath

Outer Diameter

Weight

6.1mm

40kg/km

Specifications

Frequency(MHz) Attenuation (dB/100m, Max.) NEXT(dB/100m, Min.) ELFEXT (dB/100m, Min.) Return Loss (dB, Min.)

1 2.1 65

4 4.1 56

10 6.5 50

16 8.2 47

64

52

44

41

20

23

25

25

20 9.2 46 38 25

31.25 11.7 43

17.0 38

34 23.5

28 21.562.5

22.0 35 24 20100

Transmission characteristics

0102

04 05

03

06

07

Page 17: FIBER OPTIC CABLEhscnci.com/.../2019/06/hyesung_fiber_optic_cable_2018.pdf · 2019-06-11 · Micro duct installation Installed in air blown method-----Feature Standard fiber count:

Hybrid Cable 14

Optical Fiber

Strength Member

Copper Condurctor

Outer Sheath

01

02

03

04

HY

BR

ID C

AB

LE

17

Applications

Remote powering of network access devicesLow voltage DC devices

-----

--

Feature

Higher power and longer distancesSpeed installationEasy stripping and spiltPolarization indentationNo special tools or mounting hardware required

Construction

Characteristics Specifications

1,350N

400N

Short Term

Long TermTensile Load

30mm

Installation -30℃ - + 60℃

Operation -40℃ - + 70℃

Bending Radius80mm

Temperature Range

Mechanical & environmental Characteristics

Powered Fiber Optic Cable

Fiber Count Central Tube diameter(mm) Outer Diameter(mm) Weight (km/kg)

1- 12 3.0 9.0 X 4.3 35.8

Specifications

01

0204

03

Page 18: FIBER OPTIC CABLEhscnci.com/.../2019/06/hyesung_fiber_optic_cable_2018.pdf · 2019-06-11 · Micro duct installation Installed in air blown method-----Feature Standard fiber count:

Toning Conductor

Filling Compound

Dielectric Strength Members

Fiber

Buffer Tube

Polyethylene(PE) Outer Jacket

TO

NE

AB

LE D

RO

P C

AB

LE

18

01

02

03

04

05

06

Toneable Drop Cable15

Applications

Construction

Drop cablesBroadband networkLocal loopFTTXAerial or direct bury

-----

-----

Feature

Universal designMaximum bandwidthExcellent crush resistanceReduces cable prep and installation timeEasy location after installation

Fiber Count Conductor Size (AWG) Width (mm) Height (mm) Weight (km/kg)

16 10.91 - 2

12 12

4

4.5

70

-

Specifications

Characteristics Specifications

440N

132N

Crush Resistance 2,200N/mm

Loaded

Short Term

Long Term

30mm

Unloaded 50mm

Installation -10℃ - + 60℃

-40℃ - + 70℃Operation

Tensile Load

Axis Bending Radius

Temperature Range

Mechanical & environmental Characteristics

01

02

0405

03

06

Page 19: FIBER OPTIC CABLEhscnci.com/.../2019/06/hyesung_fiber_optic_cable_2018.pdf · 2019-06-11 · Micro duct installation Installed in air blown method-----Feature Standard fiber count:

01 02 03 04

05 06 07 08

Certificates

CE

RT

IFICA

TE

S

19

SYSTEM

Cerificate No. Description

ISO 9001: 2008 QMS-3102

ISO 14001: 2004 EMS-0642

Quality Management System

Environmental Management System

OHSAS 18001: 2007 HSS-0109 Health & safety Management System

TL 9000 R 5.5/R 5.0 TLS-0028 Quality Management System

PRODUCTS

Cerificate No. Product Description

20141017-E469705

20141018-E469705

OFN - Round drop cable

OFC - F-8 flat drop cable

UL 20170814-E469705 OFNR - Distribution cable

20170801-E469705 OFNP - Distribution cable

20171024-E469705 OFCP - Interlock armored cable

Fiber Optic Distribution Cable (12C-24C)

Indoor & Outdoor Round Cable(1C)

Class D(Dca-s2, d0) Indoor & Outdoor Round Cable(2C)

Indoor & Outdoor Round Cable(4C)

CPR(CE) Indoor & Outdoor Round Cable(8C)

F-8 Flat Type Cable (2C)

Class E(Eca)Indoor & Outdoor Round Cable(12C)

Flat Optical Fiber Cable (1C-4C)

5022422/01-1

5022422/03-1

5022422/04-1

5022422/05-1

5022422/06-1

5022422/02-1

5022422/07-1

5022422/08-1

5022422/09-1 Fiber Optic Distribution Cable (48C)

Merianstraße 28, 63069 Offenbach, Deutschland/ GermanyTelefon/Phone +49 69 83 06-0, Telefax: +49 69 83 06-555 E-Mail/e-mail: [email protected], http://www.vde-institut.com

Classification report 5022422/01-1 HSCC-16-PSX003 Seite/page 1 von/of 6

CLASSIFICATION REPORTof reaction to fire for electric cables

1 Introduction This classification report defines the classification assigned to the cable types HSCC-16-PSX003 in accordance with the procedures given in EN 13501-6.

CLASSIFICATION OF REACTION TO FIRE FOR ELECTRIC CABLES

IN ACCORDANCE WITH EN 13501-6

Sponsor: HYESUNG Cable & Communication INC. 18 Samginonggongdanji-gil, Samgi-myeon IKSAN-SI Jeollabuk-do South Korea

Prepared by: VDE Prüf- und Zertifizierungsinstitut GmbH* Merianstraße 28, 63069 Offenbach, Deutsch-land

Notified Body No: 0366*

Product name: HSCC-16-PSX003

Classification report No: 5022422/01-1

Issue number: 1

Date of issue: 2017-08-07

This classification report consists of 6 pages and may only be used or reproduced in its entirety.

* To be used for CE marking only

Merianstraße 28, 63069 Offenbach, Deutschland/ GermanyTelefon/Phone +49 69 83 06-0, Telefax: +49 69 83 06-555 E-Mail/e-mail: [email protected], http://www.vde-institut.com

Classification report 5022422/06-1 HSCC-16-PSX004/8 Seite/page 1 von/of 6

CLASSIFICATION REPORTof reaction to fire for electric cables

1 Introduction This classification report defines the classification assigned to the cable types HSCC-16-PSX004 / 8 in accordance with the procedures given in EN 13501-6.

CLASSIFICATION OF REACTION TO FIRE FOR ELECTRIC CABLES

IN ACCORDANCE WITH EN 13501-6

Sponsor: HYESUNG Cable & Communication INC. 18 Samginonggongdanji-gil, Samgi-myeon IKSAN-SI Jeollabuk-do South Korea

Prepared by: VDE Prüf- und Zertifizierungsinstitut GmbH* Merianstraße 28, 63069 Offenbach, Deutsch-land

Notified Body No: 0366*

Product name: HSCC-16-PSX004 / 8

Classification report No: 5022422/06-1

Issue number: 1

Date of issue: 2017-08-30

This classification report consists of 6 pages and may only be used or reproduced in its entirety.

* To be used for CE marking only

Page 20: FIBER OPTIC CABLEhscnci.com/.../2019/06/hyesung_fiber_optic_cable_2018.pdf · 2019-06-11 · Micro duct installation Installed in air blown method-----Feature Standard fiber count:

FIBE

R O

PTIC

CA

BLE

PR

OD

UC

T CA

TALO

GU

E

Seoul Office

5ht Fl. Lasung Bldg., 59 Naruteo-ro, Seocho-gu, Seoul, Korea

Tel .

Fax .

+82 2 707 0230

+82 2 707 0232

Iksan Factory

18 Samginonggongdanji-gil, Samgi-myeon, Iksan-si, Jeollabuk-do, Korea

Tel .

Fax .

Home2018 June. HYESUNG CABLE & COMMUNICATION INC. All Rights Reserved. Printed in KOREA

+82 63 858 7005

+82 63 858 8537

www.hscnci.com

WE

SE

RVE

YO

U TH

E B

ES

T & W

E S

ATIS

FY Y

OU

THE

BE

ST