Page 1: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020 1

FIBCOM STM 1/4/16 EQUIPMENT (6325)By V.SRINATH ITX2

TCT 6A VER 1.0

IRIS

ET

Page 2: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020TCT6A VER 1.0

2

World’s smallest fully-featured MSPP (multi-service provisioning platform) Network Elements–SDXC, ADM1, ADM4, ADM16SDH interfaces–STM-1, STM-4, STM-16PDH interfaces–E1Ethernet interfaces–Fast Ethernet and Gigabit EthernetRedundant architecture–Cross-connection & synchronization protection–Power Supply protection

FIBCOM 6325 Edge Node, Overview

IRIS

ET

Page 3: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020 TCT6A VER 1.0

BLOCK DIAGRAM OF 6325 NODE

3

IRIS

ET

Page 4: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020TCT6A VER 1.0

4

Front view of SUB RACK

5

4

3

2XC and/or Traffic

6

Reserve

d7CMCC

8PS

9 PS Redundant

1

FAN

XC and Traffic

Traffic

Traffic

•Install the traffic module performing the cross-connect function in slot 3•If the configuration requires protection of the module performing the cross-connect function, then install the traffic module performing the protection of the cross-connect function in slot 2• Install other traffic modules, extending the number of interfaces, in position 2, 4 and 5

FIBCOM 6325 node is housed in a 1 U high sub rack SC2

IRIS

ET

Page 5: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020TCT6A VER 1.0

5

• SIMX-16 (SDH INTERFACE MODULE CROSSCONNECT -16)STM-16 CROSS CONNECT MODULE

•SIMX -4 (SDH INTERFACE MODULE CROSSCONNECT -4) STM-4 CROSS CONNECT MODULE

•SPMIX with 21E1s (SDH - PDH INTERFACE MODULE CROSSCONNECT)

STM-1 CROSS CONNECTMODULE WITH 21E1

•PIM1 (PDH INTERFACE MODULE-1)PDH INTERFACE PROVIDES EXTRA 21 E1S

TRAFFIC MODULES FOR 6325 NODE

IRIS

ET

Page 6: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020TCT6A VER 1.0

6

•EMAP (ETHERNT MAPPING) ETHERNET I/F MODULE (SUPPORTS 4 10/100 ETHERNET CIRCUITS)

•ETEX 10S(SUPPORTS FAST ETHERNET AS WELL AS GIGABIT

ETHERNET CIRCUITS)

TRAFFIC MODULES FOR 6325 NODE

IRIS

ET

Page 7: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020TCT6A VER 1.0

7

DESCRIPTION OF MODULES

XC and/or Traffic

CMCC

PS

PS Redundant

FAN

XC and Traffic

Traffic

Traffic

STM-16STM-1/4 STM-1/4 STM-1/4 STM-1/4

1 2 3 4 5

SIMX16

Act./Stdby

SafeRem.

Remove

UCH

Module – SIMX16

• SIMX-16 is the SDH interface module with cross-connect functions containing the interfaces

• 1 x STM-16 (with SFP)• 4 x STM-1/STM-4 (with SFP)• 1 x User Channel / Engineering order wire(EOW)• Works only in slot no.2 and 3

IRIS

ET

Page 8: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

TCT6A VER 1.08

Modules – SIMX4

DESCRIPTION OF MODULES

XC and/or Traffic

CMCC

PS

PS

FAN

XC and Traffic

Traffic

Traffic

STM-1/4 STM-1/4 STM-1/4 STM-1/4

1 2 3 4

SIMX4

Act./Stdby Safe

Rem.

Remove

UCH

SIMX-4 is the SDH interface module with cross-connect functions containing the interfaces:•4 X STM-1 /STM-4 (with SFP)•1 x User Channel / EOW•Works in any traffic slot

7/22/2020

IRIS

ET

Page 9: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020TCT6A VER 1.0

9

DESCRIPTION OF MODULES

XC and/or Traffic

CMCC

PS

PS

FAN

XC and Traffic

Traffic

Traffic

SPIMX with 21E1s is the SDH and PDH interface module with cross-connect functions containing the interfaces• 2 X STM-1 /STM-4 (with SFP)•21 x 2 Mbps (E1) 120 Ω• Works in any traffic slot

Modules – SPIMX

STM-1/4STM-1/4

1 2

SPIMX

Act./Stdby SafeRem.

Remove

IRIS

ET

Page 10: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020TCT6A VER 1.0

10

DESCRIPTION OF MODULES

XC and/or Traffic

CMCC

PS

PS

FA

N

XC and Traffic

Traffic

Traffic

Modules – PIM1

PIM1 is the PDH interface module with the interfaces

Two variants:

21 x E1 120 Ohm

75 Ohm available with external Baluns

Works only slot nos 2,4 and 5

PIM1

(21 * E1 SafeRem.

Remove

FAN

IRIS

ET

Page 11: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020TCT6A VER 1.0

11

XC and/or Traffic

CMCC

PS

PS

FAN

XC and Traffic

Traffic

Traffic

DESCRIPTION OF MODULESModules – EMAP

FE FE

1 2

EMAP

1 2 3 4

FE FE FE FE SafeRem.

Remove

•2 x FE (RJ-45 or with SFP)•2 x FE (RJ-45)•GFP Mapping into SDH•Virtual Concatenation•LCAS

Works only slot nos 2,4 and 5

IRIS

ET

Page 12: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

TCT6A VER 1.012

Virtual concatenation (VCAT)

•It is an inverse multiplexing technique creating a large capacity payload container distributed over multiple smaller capacity TDM signals

•These signals may be transported or routed independently. Virtual concatenation has been defined for SONET/SDH, OTN and PDH path signals

7/22/2020

IRIS

ET

Page 13: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

TCT6A VER 1.013

Link Capacity Adjustment Scheme(LCAS)

•Link Capacity Adjustment Scheme or LCAS is a method to dynamically increase or decrease the bandwidth of virtual concatenated containers

•The LCAS protocol is specified in ITU – T G.7042•It allows on-demand increase or decrease of the bandwidth of the virtual concatenated group in a hitless manner.

•This brings bandwidth-on-demand capability for data clients like Ethernet when mapped into TDM containers.

7/22/2020

IRIS

ET

Page 14: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

TCT6A VER 1.014

•LCAS is also able to temporarily remove failed members from the virtual concatenation group failed member will automatically cause a decrease of the bandwidth and after repair the bandwidth will increase again in a hitless fashion

•Together with diverse routing this provides survivability of data traffic without requiring excess protection bandwidth allocation.

Link Capacity Adjustment Scheme(LCAS)

7/22/2020

IRIS

ET

Page 15: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

TCT6A VER 1.015

DESCRIPTION OF MODULESETEX10S module

ETEX 10S is the Ethernet switching and mapping module with interfaces•4 x GbE (with SFP)•2 x FE (with SFP)•4 x FE (RJ-45)•Occupies two slots

XC and/or Traffic

CMCC

PS

PS

FA

N

XC and Traffic

Traffic

Traffic

ETEX

1 2 3 4

SafeRem.

Remove

CT

GbE GbE GbE GbE

FE

FE FE

MGT

7/22/2020

IRIS

ET

Page 16: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

TCT6A VER 1.016

Modules – CMCC

DESCRIPTION OF MODULES

Master controller •Internally the FIBCOM 6325 node is managed by the CMCC module

•CMCC contains a non-volatile memory for the application SW of the network element. This memory can contain at least two versions of the SW and download of new SW while in service is possible.

7/22/2020

IRIS

ET

Page 17: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

TCT6A VER 1.017

XC and/or Traffic

CMCC

PS

PS

FA

N

XC and Traffic

Traffic

Traffic

MGT CT

Res/

Rem.

Act./

StdbySafeRem.

Pwr/Alarm

1 x Management Interface – Ethernet port

– For Network Manager or Extended Craft Terminal

1 x Craft Terminal Interface – Serial port

– For standard Craft Terminal

DESCRIPTION OF MODULESModules – CMCC

7/22/2020

IRIS

ET

Page 18: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

TCT6A VER 1.018

DESCRIPTION OF MODULESFan and Sync/Alarm interface

XC and/or Traffic

CMCC

PS

PS

FA

N

XC and Traffic

Traffic

Traffic

SY

NC

/

Ala

rm

4 x AUX port configurable as input or output alarms

T3 and T4 Synchronisation interfaces

– T1/SDH & T2/E1 synchronisation on traffic modules also supported7/22/2020

IRIS

ET

Page 19: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

TCT6A VER 1.019

DC/DC ConverterDESCRIPTION OF MODULES

XC and/or Traffic

CMCC

PS

PS

FA

N

XC and Traffic

Traffic

Traffic

DC -48/60V

Act./

Stdby

DC -48/60V

Act./

Stdby

Redundant DC/DC Converters (75W/85W)

1:1 or 1+1 Protection (configurable)

External AC/DC Adapters are available7/22/2020

IRIS

ET

Page 20: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

TCT6A VER 1.020

BLOCK DIAGRAM OF POWER SUPPLY MODULE

7/22/2020

IRIS

ET

Page 21: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

TCT6A VER 1.021

PLUGGABLE TRANSCEIVERS

• Small Formfactor Pluggables (SFP) used for all optical interfaces

• Application codes can be mixed on same module

• Provide features likeCWDMLong Distance applications

with external BoosterBi-directional transmission

over single fiber

7/22/2020

IRIS

ET

Page 22: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

TCT6A VER 1.022

AVAILABLE SFP TRANSCEIVERS

SDH• STM-1 Electrical, S-1.1, L-1.1, L-1.2• S-4.1, L-4.1, L-4.2, L-4.2 C-band• S-16.1, L-16.1, L-16.2, L-16.2 C-band• STM-16 CWDM (8 wavelengths)

Ethernet• 100BASE-FX, 100BASE-LX10• 1000BASE-T, 1000BASE-SX• 1000BASE-LX, 1000BASE-ZX

7/22/2020

IRIS

ET

Page 23: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

TCT6A VER 1.023

FUNCTIONS OF THE LEDS AND SWITCH

LED/Switch Indication Description

Remove - Switch to be activated before the

module is removed from the sub rack.

Safe

Removal

Yellow LED indicating that it is safe to remove

the module from the sub rack.

Active

/Stand By

(SIMX and

SPIMX only)

Off • Module is not powered

• Module is in standby mode (when

the CMCC module is not installed)

Constantly green Module is active

Slow Flashing

(0.5Hz) green

Module is in standby mode

Act (EMAP

only)

Green LED indicating activity/traffic on the

Ethernet connection

Link (EMAP

only)

Green LED indicating that link is up

7/22/2020

IRIS

ET

Page 24: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

TCT6A VER 1.024

Parameter Value Unit

Class S-1.1 L-1.1 L-1.2

Nominal Bit Rate 155.520 Mbps

Source Type MLM MLM SLM

Wavelength range 1261-1360 1263-1360 1480-1580 nm

Mean launched power range

-15 to -8 -5 to 0 -5 to 0 dBm

Min. extinction ratio 8.2 10 10 dB

Attenuation range 0 to 12 10 to 28 10 to 28 d B

Maximum dispersion

96 246 na ps/nm

Min. overload -8 -10 -10 dBm

STM-1 TRANSMISSION CHARACTERISTICS

7/22/2020

IRIS

ET

Page 25: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

TCT6A VER 1.025

Parameter Value Unit

Bit Rate 622.080 Mbps

Transceivers Class S-4.1 L-4.1 L-4.2 L-4.2 C-Band

Source Type MLM SLM SLM SLM

Wavelength range

1274-1356

1280-1335

1480-1580

1530-1565

nm

Mean launched power range

-15 to -8 -3 to +2 -3 to +2 -3 to +2 dBm

Atten. range 0 to 12 10 to 24 10 to 24 10 to 24

dB

Max.dispersion 74 na 2200 2200 ps/nm

Min RX sensitivity at BER =10-10

-28 -36 -36 -36 dBm

Min. overload -8 -8 -8 -8 dBm

STM-4 TRANSMISSION CHARACTERISTICS

7/22/2020

IRIS

ET

Page 26: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

TCT6A VER 1.026

Module Power consumption (W)CM3563 (SPIMX with 4 x E1) 6.5CM3564 (CMCC) 1.5CM3565 (Fan) 5.5CM3566 (PIM1) 4.2CM3567 (SIMX4) 6.4CM3568 (SIMX16) 8.6CM3571 (EMAP) 6.4CM3572 (ETEX10S) 53.0CM3574(SPIMX with 21x E1) 9.0

POWER CONSUMPTION OF THE DIFFERENT TYPES OF MODULES

7/22/2020

IRIS

ET

Page 27: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

TCT6A VER 1.027

CONNECTORS ON THE MODULES

Function Equipment Connector Type ModuleSTM-16 optical interface LC (with SFP transceiver) SIMX16STM-1 or STM-4 optical I/F LC (with SFP transceiver) SIMX4, SIMX16, SPIMXSTM-1 electrical interface 1.0/2.3 coaxial (with SFP

TX-RX)SIMX4, SIMX16, SPIMX

E1, 2 Mbit/s I/F, 120 Ώ MDR PIM1, SPIMX (21xE1)

UCH (DTMF- EOW). RJ-45 SIMX4, SIMX16MDR SPIMX(21xE1)

10/100 Mbps Ethernet I/F RJ-45 EMAP, ETEX 10S100 Mbit/s Ethernet I/F LC (with SFP transceiver) EMAP, ETEX 10S1000 Mbit/s Ethernet I/F LC or RJ-45 (with SFP TX-

RX)ETEX 10S

MGT, Management Ethernet interface

RJ-45 CMCC, ETEX 10S

CT, Craft terminal I/F RJ-45 CMCC, ETEX 10S2 MHz synchronization input/output and alarm I/F

9 pole DIN 41652 (male) FAN

DC power input 3 pole Molex mini-fit male) PS-DC7/22/2020

IRIS

ET

Page 28: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

TCT6A VER 1.028

•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

•The purpose of the management software is to monitor and control the behavior of the FIBCOM 6325 node and the associated transport signals

•To manage software downloading and upgrading

•Proper installation of embedded software is required to enable the unit to operate.

MANAGEMENT SOFTWARE

7/22/2020

IRIS

ET

Page 29: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

TCT6A VER 1.029

FIBCOM STM 1/4 EQUIPMENT (6320)By V.SRINATH ITX2

7/22/2020

IRIS

ET

Page 30: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020TCT6A VER 1.0

30

•The FIBCOM 6320 is a product where STM-1 and STM-4 Add/Drop Multiplexers (ADM) and Terminal Multiplexers (TM) are implemented on a single module giving VC-4, VC-3 and VC-12 connectivity

•This provides a cost efficient solution especially in small nodes, where the requirement is to add/drop a limited number of 2Mbit/s signal. .

INTRODUCTION

IRIS

ET

Page 31: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020TCT6A VER 1.0

31

•Add/drop, Terminal multiplexer and cross-connect family

• VC-12, VC-3, VC-4 level connectivity

•Up to 126 x 2 Mb/s or 6 x 34 Mb/s, tributaries in one sub-rack

•Advanced Network and Element Management

•Compact and ultra low power consumption

FEATURES

IRIS

ET

Page 32: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020TCT6A VER 1.0

32

•High reliability with extended temperature range (up to 55º C)

•Flexible architecture with a large suit of mechanical solutions

•Full Synchronization status messaging support with protection switch on synchronization sources

FEATURES

IRIS

ET

Page 33: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020TCT6A VER 1.0

33

The equipment will be arranged in thefollowing sequence

•RACK•RACK CONNECTION FIELD (RCF)•ENGINEERING ORDERWIRE (EOW)•SUB-RACK•SUBRACK CONNECTION FIELD (SRCF)•MODULES•POWER SUPPLY

MECHANICAL SYSTEM

IRIS

ET

Page 34: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020TCT6A VER 1.0

34

Field-01

Field-02

Field-03

Field-04

Field-05

•2200X600x300mm

•1600X600x300mm

RACK DIMENSIONS

IRIS

ET

Page 35: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020TCT6A VER 1.0

35

•The sub rack consists of a mechanical unit witha number of slot positions(fixed moduleguides), that together with mother board PCBdefine whether the module can be inserted forthe system application.

•Up to 3 motherboards can be mounted

•One NE uses one, two or all three motherboard groups in sub rack.

SUB RACKS

IRIS

ET

Page 36: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020TCT6A VER 1.0

36

PS

MO

DU

LE

2A

DM

/TM

5+ 6 7+ 8

AD

M/T

M

11+12

PS

MO

DU

LEP

S M

OD

ULE

13

14

AD

M/T

M

17+ 18

SRC

FR

C

F

SUB RACK FRONT VIEW

IRIS

ET

Page 37: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020TCT6A VER 1.0

37

MODULE POSITIONS

Module 1 2 3+4 5+6 7 8 9+10 11+12 13 14 15+16 17+18

TM/ADM X

S

R

C

F

LI1/RI1/TEX4 X X X X

TEX1 X X X X X

TEX31 X X X X X

TEX33 X

PS X X X X X X

IRIS

ET

Page 38: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020TCT6A VER 1.0

38

RACK CONNECTION FIELD (RCF)

•It provides the rack station alarm interface and distributes power to sub-racks

•The RCF unit accommodates up to 4/3 AC1 sub-racks and one DTMF EOW

•RCF comprises two SECTIONSLED/ALARM sectionPower supply sectionIR

ISET

Page 39: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020TCT6A VER 1.0

39

LED/Alarm section•The function is to display the alarm generated by the system

•Provision is made for display of alarms from 4 AC1 subracks at system connections

Alarm color function

A red Critical alarm

B Yellow/Orange Major alarm

R Green Remind after

acknowledgement

RACK CONNECTION FIELD (RCF)

IRIS

ET

Page 40: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

TCT6A VER 1.040

•The function of the PS section is to supply powerto AC1 sub racks and alarm section.•The supply voltage is -48V/-60VPS section consists of1. 8 terminal points for power distribution to 4 AC1 sub racks and out of 8, four are main supply from Power source A and four are protection supply through power B and supply for alarm /LED display is through power C input

2. Input ON/OFF switch is provided to supply toAC1 sub rack.

RACK CONNECTION FIELD (RCF)

Power supply section

7/22/2020

IRIS

ET

Page 41: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020TCT6A VER 1.0

41

•The SRCF for the wide sub racks with rearcable access perform just like RCF

•It is common for each and every sub rack

•It is provided at the far right position

•Indication of rack alarms, a battery powerfilter to protect against surge voltages andfuses for battery voltage is provided inSRCF

SUB RACK CONNECTION FIELD (SRCF)

IRIS

ET

Page 42: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

TCT6A VER 1.042

LED color Function

P/S Green Power ON

R Yellow Default programmed

B Red Default programmed

to B alarm

A Red Default programmed

to A alarm

Reset switchWhen this switch is activated the modules in the sub rack will perform a hardware reset

SUB RACK CONNECTION FIELD (SRCF)

7/22/2020

IRIS

ET

Page 43: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

TCT6A VER 1.043

The FIBCOM 6320 node cards can be divided into1.Aggregate cardsAggregate cards contain a complete stand-alone ADM including two aggregate interfaces (STM-1 or STM-4), 21 x 2 tributary interfaces, switch matrix, synchronization function and management function.

2.Tributary cardsTributary cards provide extra tributary interfaces

3. Support cardsPower supply cards

MODULES

7/22/2020

IRIS

ET

Page 44: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

TCT6A VER 1.044

STM-1 ADD/DROP MULTIPLEXER MODULE – ADM1

LEDs

Master module(Green LED)It indicates that it is a master module of the network element

Alarm (Red LED)This LED indicates non acknowledged alarms in the net work element

7/22/2020

IRIS

ET

Page 45: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

457/22/2020 TCT6A VER 1.0

IRIS

ET

Page 46: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020TCT6A VER 1.0

46

2MBPS TRIBUTARY EXTENSION MODULE-TEX-1

•It is used to increase the number of tributary interfaces

•Each TEX-1 module provides 21X2Mbps tributary interfaces

•TEX modules are available in 120/75 ohms variantsIR

ISET

Page 47: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020TCT6A VER 1.0

47

BLOCK DIAGRAM OF TEX-1 MODULE

IRIS

ET

Page 48: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020TCT6A VER 1.0

48

•The TEX3 Tributary Extension Module is used to access the VC-3 of the STM-l signal

•The TEX3 exist as TEX31 and TEX33 modules. (See Fig. 1.8 and Fig.1.9)

•The TEX31 module accesses one VC-3 whereas the TEX33 accesses three VC-3s.

34 M BIT/S TRIBUTARY EXTENSION MODULE — TEX3

IRIS

ET

Page 49: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020TCT6A VER 1.0

49

FRONT VIEW OF TEX3

IRIS

ET

Page 50: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020TCT6A VER 1.0

50

BLOCK DIAGRAM OF TEX3

IRIS

ET

Page 51: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020TCT6A VER 1.0

51

•The Ring Interconnect module provides two optical or electrical STM- 1 tributary interfaces

RING INTERCONNECT MODULE-RI1

IRIS

ET

Page 52: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020TCT6A VER 1.0

52

BLOCK DIAGRAM OF RI1

IRIS

ET

Page 53: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020TCT6A VER 1.0

53

•The Line Interconnect module provides one optical or electrical STM-l tributary interface. In configurations with optical output signal the module holds an optical sub-assembly

LINE INTERCONNECT MODULE - LI1

IRIS

ET

Page 54: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020TCT6A VER 1.0

54

BLOCK DIAGRAM OF LI1

IRIS

ET

Page 55: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020TCT6A VER 1.0

55

Red LED StateConstantly Off Normal condition (or no Power).Slow flashing The module performs a self-test or is in a

state of hardware failure.Fast flashing The module is either booting or initializing

Software.

Constantly ON

The network element has a non-acknowledged A or B alarm, or hardware failure.

•All traffic /controller modules contain one red LED with the following states.

LEDS ON MODULES

Slow flashing means approximately 1 Hz and fast flashing means approximately 4 Hz. The master module contains a green LED

IRIS

ET

Page 56: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020TCT6A VER 1.0

56

•The power supply operates from 48 V. •The DC/DC converter block consists of Input Section, Output Section and Control Section

•The circuit automatically selects one of two inputs as main or protection

•By means of straps, the user can determine whether -UB1 or -UB2 is set as main or protection source

•The input is common-mode filtered and protected against over - and reverse voltage

POWER SUPPLY MODULE - PS

IRIS

ET

Page 57: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020TCT6A VER 1.0

57

•Two filtered and equal output voltages of +5 V and -5 V are obtained

• It is possible to implement N + l protection of power supplies for redundancy purpose.

POWER SUPPLY MODULE - PS

IRIS

ET

Page 58: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020TCT6A VER 1.0

58

•Acknowledge buttonA push button used to acknowledge the current rack alarm (only the power supply configuration using the red LED will generate rack alarms).

•F-InterfaceA five-pole connector for connecting a Craft Terminal.

FRONT VIEW OF POWER SUPPLY CARD

IRIS

ET

Page 59: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020TCT6A VER 1.0

59

BLOCK DIAGRAM OF POWER SUPPLY CARD

IRIS

ET

Page 60: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020TCT6A VER 1.0

60

•The Master Modules (ADM/TM modules) of thenetwork element hold the embedded applicationsoftware for the whole network element in apermanent storage medium

•TRIB modules will load software from the mastermodule

•The hardware and the embedded applicationsoftware are regarded as separate items, whileordering both items must be ordered to get anoperational system.

EMBEDDED SOFTWARE FOR NETWORK ELEMENTS

IRIS

ET

Page 61: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020TCT6A VER 1.0

61

•In general the master modules will be delivered with only basic software that makes it possible to download the application software locally or remotely

•The network element is not able to perform any system functions until the embedded application software is downloaded.

EMBEDDED SOFTWARE FOR NETWORK ELEMENTS

IRIS

ET

Page 62: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020TCT6A VER 1.0

62

TROUBLESHOOTING IN FIBCOM STM EQUIPMENT

IRIS

ET

Page 63: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020TCT6A VER 1.0 63

Sl.No

Alarmreported

Probable causes Corrective actions

1. STM-1PORTLoss ofsignal (LOS)

No signal is received at receiver port1.Fiber break Auto Laser Shutoff (ALS)

2.Far end TX forced OFF3.Far end TX module faulty4.Receiver patch cord dirty/faulty5.Receiver faulty

1.Restore fiber break. System restores automatically2.Force far end TX ON through NMS3.Replace far end ADM1

4.Clean/replace patch cord5.Replace ADM1module

IRIS

ET

Page 64: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020TCT6A VER 1.0 64

Sl.

No

Alarm

reported

Probable causes Corrective actions

2.

3.

PDH PORTLoss of signal

VC-12 PORT path unequipped

No input at the PDH input port due to 1.No signal from lower order system TX2.DDF wiring faulty3.Rx faulty

1.No Tributary connections2. Cross connect failure

1.Repair lower order systems2.Repair DDF wiring3.Replace ADM1/TM1 module

1.Make connections through NMT2.Replace ADM1module

IRIS

ET

Page 65: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020 TCT6A VER 1.0 65

Sl.No

Alarmreported

Probable causes Corrective actions

4.

5.

Unit main type mismatch

Unit missing

Equipment present and expected not matching in the “ main type”1.Equipment present are less in number than expected modules2.Particular module faulty

Copy expected to present in the equipment menu

1.Copy expected to present in the equipment menu

2.Replace faulty module

IRIS

ET

Page 66: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020TCT6A VER 1.0

66

S.No. Alarm reported Probable causes Corrective actions

6.7.

8.

9.

10.

STM-1 PORT TX failSTM-1 PORT TX degradedSTM-1 PORT TX power too lowSTM-1 PORT TX power too highSTM-1 PORT Laser bias current too high

TX faulty

TX faulty

TX faulty

TX faulty

TX faulty

Replace ADM Module

Replace ADM Module

Replace ADM Module

Replace ADM Module

Replace ADM ModuleIRIS

ET

Page 67: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020TCT6A VER 1.0

67

Sl. No.

Alarmreported

Probable causes Corrective actions

11. Loss of reference source (SDH)T1

1.Fiber break Auto Laser Shutoff (ALS)

2.Far end TX forced OFF3.Far end TX module faulty4.Receiver patch cord dirty/faulty5. Receiver faulty

1.Restore fiber break. System restores automatically2.Force far end TX ON through NMS3.Replace far end ADM1 module4.Clean/replace patch cord5.Replace ADM1module

IRIS

ET

Page 68: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020TCT6A VER 1.0

68

12.

13.

Loss of reference source (PDH)T1

Selector A Out of locked

1.No signal from lower order system TX2.DDF wiring faulty3.Rx faulty

Selected clock source input may not be available

1.Repair lower order systems

2.Repair DDF wiring3.Replace ADM1 module

Same action as 11 & 12

Sl. No.

Alarmreported

Probable causes Corrective actions

IRIS

ET

Page 69: FIBCOM STM 1/4/16 EQUIPMENT (6325) By V.SRINATH ITX2 …122.252.230.113/content/ppt/tele/TCT_6Ahl.pdf•The FIBCOM 6325 node can be managed by 6300 manager, 8000 manager and F6300EM

7/22/2020TCT6A VER 1.0

69

S.No.

Alarmreported

Probable causes Corrective actions

14. Selector B Out of locked

Same causes as in case 13

Same actions as in case 13

15. Selector B(0) timing quality low

1. Selected quality level of clock not matching

2. Clock recovery section faulty

1.Properly select the quality of the selected source in NMS2.Replace ADM1/TM1

16. Unit temp. too high

1. Particularmodule faulty

Replace faulty module