FE-RAKE DETAILSTABLE OF CONTENTS FE-RAKE DETAILS FE2010 - NBS - RAKE DETAIL W/WALL PANEL FE2015 -...
Transcript of FE-RAKE DETAILSTABLE OF CONTENTS FE-RAKE DETAILS FE2010 - NBS - RAKE DETAIL W/WALL PANEL FE2015 -...
RAKE DETAILSFE2010-NBS - RAKE DETAIL w WALL PANELSFE2015-NBS - RAKE DETAIL w ROOF JOIST & WALL PANELSFE2050-NBS - OPEN RAKE DETAIL w WALL CONSTRUCTION BY OTHERSFE2055-NBS - STARTING RAKE DETAIL w JOIST & WALL SYSTEM BY OTHERSFE2610-NBS - STARTING RAKE DETAIL w INSULATED WALL SYSTEMFE2615-NBS - RAKE DETAIL w ROOF JOIST & INSULATED WALL SYSTEM
TABLE OF CONTENTS
SL
LOWER INSULATION
ROOF SECONDARY MEMBER (SHAPE VARIES)
UPPER INSULATION
WALL INSULATION
R-Boost™ RAKE DETAIL
FE2010RAKE DETAIL w/ STANDARD WALL PANELS
RAKE TRIM RTA__
H1030 AT 4" O.C.
THERMAL BLOCK(IF REQ'D)
ROOF PANEL
H1020 FASTENER
RAKE TRIM CLEAT RRA01 W/(H1060) FASTENERS @ 12" O.C.
CLASSIC H3400
ACCENTREV. CLASSIC
H3420H3410
* WALL PANEL MARK No.OUTSIDE PANEL CLOSURES
*
INSULATION BRIDGE MK. EIB24
SEE ABOVE FOR FASTENERREQUIREMENTS FOR IRC &INSULATION TIE OFF
RAKE SUPPORT CLIP MK. CL21STw/ (2) H1220 FASTENERSAT EACH PURLIN(SEE DETAIL ABOVE)
2 1/4" TAPE MASTIC MK. H3020BETWEEN TRIM & ROOF PANEL
START/FINISH DIM.1/4"STEEL LINE
VARIES
TOP
OFBR
IDGE
TOP O
FPA
NEL
H1020 FASTENERAT EACH SUPPORT
WALL PANEL
RAKE ANGLEMK. MAR01
CLOSURE
WALL STRUCTURAL FASTENER
RETAINER CEE MK. IRC
(2) H1220 FASTENERS AT EACHCL21ST UNDER RAKE ANGLEFOR SUPPORT (DO NOT ATTACHTO TO RAKE ANGLE)
ALT. CL21ST SUPPORT CLIP INSTALLATION DETAIL
H1020/H2200 EACH END & 2'-0"O.C. BETWEEN PURLINS TO TIEDOWN INSULATION
INSULATION BRIDGEMK. EIB24
RAKE ANGLEMK. MAR01
RETAINER CEEMK. IRC
(2) H1220FASTENERS
*
**
RAKE SUPPORT CLIP CL21ST@ EACH PURLIN
ERECTOR NOTE:STARTING RAKE CONDTION IS SHOWN. BRIDGE PREPARATION WILL VARY BETWEEN THE STARTINGAND ENDING RAKES, SEE BRIDGE INSTALLATION DETAILS FOR SPECIFIC BRIDGE REQUIREMENTS.
*
H1020FASTENERS
*
H1020 FASTENERAT EACH SUPPORT(2) H1070 FASTENERS @ EACH PURLINPRIOR TO INSULATION BEING INSTALLED
RAKE SUPPORT ANGLE, RSA_
USED WHEN WALL PANELS ARE INSTALLED FIRST
SUPER TALL 4 7/8"TALL 3 7/8"***
H1020 AT 24" O.C. W/ 3/4" TAPE MASTIC, MK. (H3000)BETWEEN ROOF PANEL & RAKE SUPPORT ANGLE
Detail Size (W x H) :By :
: CERTIFIED ERECTION DETAILSIssuedIssued
Detailer Notes:
Download the DWG file by clicking here.
RAKE DETAILSR-Boost™ ELEVATED INSULATION SYSTEM
FE2010 - RAKE DETAIL w/ WALL PANELS
02.12.21 (MR2021.003)DLM
1 x 2
1) Default option for Wall Closures is shown as being required. Detailer must manually remove illustrations if needed.
SL
LOWER INSULATION(NOT BY NBG)
ROOF JOIST
UPPER INSULATION(NOT BY NBG)
WALLINSULATION
FE2015RAKE DETAIL w/ ROOF JOIST AND STANDARD WALL PANELSR-Boost™ RAKE DETAIL
RAKE ANGLEMK. MAR01
THERMAL BLOCK (IF REQ'D)
ROOF PANEL
1/4 - 14 X 1 1/4"(H1020) FASTENER
RAKE SUPPORT CLIP MK. CL21STw/ (2) H1220 FASTENERS @ EACHJOIST (INSTALL PRIOR TO WALLPANEL SEE DETAIL ABOVE)
INSULATION BRIDGE MK. EIB24RAKE TRIMMK. RTA_
RAKE TRIM CLEAT MK. RRA01 w/(H1060) FASTENERS @ 1'-0" O.C.
CLASSIC H3400
ACCENTREV. CLASSIC
H3420H3410
* WALL PANEL MARK No.OUTSIDE PANEL CLOSURES
*
TOP
OFBR
IDGE
TOP
OFPA
NEL
VARIES
1 1/2"
MIN
BOTTOM OFRAKE ANGLE
START/END DIM. / CUT PANEL DIM. (SEE PLAN)1/4"STEEL LINE
(2) H1220 FASTENERS @ EACHJOIST UNDER RAKE ANGLEFOR SUPPORT.(DO NOT ATTACH TORAKE ANGLE)
H1070 FASTENER@ EACH SUPPORT
WALL PANEL
RETAINER CEE MK. IRC
PANEL CLIP w/(2)H1020 FASTENERS
WALL STRUCTURAL FASTENER
CLOSURE
ERECTOR NOTE:STARTING RAKE CONDTION IS SHOWN. BRIDGE PREPERATION WILLVARY BETWEEN THE STARTING AND ENDING RAKES, SEE BRIDGEINSTALLATION DETAILS FOR SPECIFIC BRIDGE REQUIREMENTS.
*
*
ALT. CL21ST SUPPORT CLIP INSTALLATION DETAIL
H1070/H2200 EACH END & 2'-0"O.C. BETWEEN PURLINS TO TIEDOWN INSULATION
INSULATION BRIDGEMK. EIB24
RAKE ANGLEMK. MAR01
RETAINER CEEMK. IRC
(2) H1220FASTENERS
*
**
RAKE SUPPORT CLIP CL21ST@ EACH PURLIN
H1020FASTENERS
H1070 FASTENERAT EACH SUPPORT(2) H1070 FASTENERS @ EACH PURLINPRIOR TO INSULATION BEING INSTALLED
USED WHEN WALL PANELS ARE INSTALLED FIRST
SUPER TALL 4 7/8"TALL 3 7/8"***
SEE ABOVE FOR FASTENERREQUIREMENTS FOR IRC &INSULATION TIE OFF
H1030 AT 4" O.C. 2 1/4" TAPE MASTIC MK. H3020BETWEEN TRIM & ROOF PANEL
RAKE SUPPORT ANGLE, RSA_
H1020 AT 24" O.C. W/ 3/4" TAPE MASTIC, MK. (H3000)BETWEEN ROOF PANEL & RAKE SUPPORT ANGLE
Detail Size (W x H) :By :
: CERTIFIED ERECTION DETAILSIssuedIssued
Detailer Notes:
Download the DWG file by clicking here.
RAKE DETAILSR-Boost™ ELEVATED INSULATION SYSTEM
FE2015 - RAKE DETAIL w/ROOF JOIST & WALL PANELS
02.12.21 (MR2021.003)DLM
1 x 2
1) WALL CLOSURES SUPPLIED IS THE DEFAULT OPTION WITH THIS DETAIL. IF CLOSURES ARE NOTREQUIRED PER CONTRACT. DETAILER MUST MODIFY ILLUSTRATIONS ACCORDINGLY.
LOWER INSULATION
ROOF SECONDARY MEMBER (SHAPE VARIES)
INSULATION BRIDGE MK. EIB24
R-Boost™ OPEN RAKE DETAIL
FE2050STARTING RAKE DETAIL, OPEN FOR WALL w/CONSTRUCTION BY OTHERS
WALL SYSTEM(BY OTHERS)
RAKE TRIMMK. RTA__
2 1/4" TAPE MASTIC H3020BETWEEN TRIM & ROOF PANEL
ROOF PANEL
RAKE TRIMCLEAT RRA01
H1020 FASTENER
THERMAL BLOCK (IF REQ'D)PANEL CLIP w/(2)
H1020 FASTENERS
RAKE SPACERTRIM MK. RST-1
(H1060) SMS @ 12"O.C.
H1030 AT4" O.C.
(2) H1220 FASTENERS@ EACH PURLINUNDER RAKE ANGLEFOR SUPPORT. (DONOT ATTACH TORAKE ANGLE)
RAKE ANGLEMK. MAR02
FIELD CUTBRIDGE
RETAINER CEEMK. IRC__
RAKE SUPPORT CLIP MK. CL21ST w/ (2) H1220FASTENERS @ EACH PURLIN (INSTALL PRIOR TOWALL PANEL SEE DETAIL ABOVE)
FASTENER12" O.C. MAX.(BY OTHERS)
RAKE SUPPORTANGLE RSA_
START/END DIM. / CUT PANEL DIM. (SEE PLAN)1/4"STEEL LINE
(NOT BY NBG)
(NOT BY NBG)
*
ERECTOR NOTE:STARTING RAKE CONDTION IS SHOWN. BRIDGE PREPERATION WILLVARY BETWEEN THE STARTING AND ENDING RAKES, SEE BRIDGEINSTALLATION DETAILS FOR SPECIFIC BRIDGE REQUIREMENTS.
*
UPPER INSULATIONRAKE ANGLEMK. MAR02
SEE ABOVE FOR FASTENERREQUIREMENTS FOR IRC &INSULATION TIE OFF
H1020 AT 24" O.C. W/ 3/4" TAPE MASTIC, MK. (H3000)BETWEEN ROOF PANEL & RAKE SUPPORT ANGLE
ALT. CL21ST SUPPORT CLIP INSTALLATION DETAIL
H1020/H2200 EACH END & 2'-0"O.C. BETWEEN PURLINS TO TIEDOWN INSULATION
INSULATION BRIDGEMK. EIB24
RAKE ANGLEMK. MAR01
RETAINER CEEMK. IRC
(2) H1220FASTENERS
*
**
RAKE SUPPORT CLIP CL21ST@ EACH PURLIN
H1020FASTENERS
H1020 FASTENERAT EACH SUPPORT(2) H1070 FASTENERS @ EACH PURLINPRIOR TO INSULATION BEING INSTALLED
USED WHEN WALL PANELS ARE INSTALLED FIRST
SUPER TALL 4 7/8"TALL 3 7/8"***
Detail Size (W x H) :By :
: CERTIFIED ERECTION DETAILSIssuedIssued
Detailer Notes:
Download the DWG file by clicking here.
RAKE DETAILSR-Boost™ ELEVATED INSULATION SYSTEM
FE2050 - OPEN RAKE DETAIL w/ WALL CONSTRUCTION BY OTHERS
02.12.21 (MR2021.003)DLM
1 x 2
1) N/A
R-Boost™ OPEN WALL RAKE DETAIL
FE2055STARTING RAKE DETAIL w/ JOIST AND WALL OPEN FOR WALL SYSTEM BY OTHERS
LOWER INSULATION
UPPER INSULATION
INSULATION BRIDGEMK. EIB24
THERMAL BLOCK(IF REQ'D)
ROOF JOIST
WALL SYSTEM(BY OTHERS)
RAKE TRIMMK. RTA__
RAKE TRIMCLEAT MK. RRA01
RAKE SPACERTRIM MK. RST1__
(H1060) SMS@ 12" O.C.
(2) H1220 FASTENERS @EACH JOIST UNDER RAKEANGLE FOR SUPPORT.(DO NOT ATTACH TORAKE ANGLE)
RAKE ANGLEMK. MAR02
H1070 FASTENER@ EACH SUPPORT
RAKE ANGLEMK. MAR02
FIELD CUTBRIDGE
H1020 FASTENER
RETAINER CEEMK. IRC__
FASTENER 12" O.C.MAX. (BY OTHERS)
PANEL CLIP W/(2)H1020 FASTENERS
(NOT BY NBG)
(NOT BY NBG)
START/END DIM. / CUT PANEL DIM. (SEE PLAN)1/4"STEEL LINE
C OF 1ST PANEL RIBL
*
ERECTOR NOTE:STARTING RAKE CONDTION IS SHOWN. BRIDGE PREPERATION WILLVARY BETWEEN THE STARTING AND ENDING RAKES, SEE BRIDGEINSTALLATION DETAILS FOR SPECIFIC BRIDGE REQUIREMENTS.
*
ALT. CL21ST SUPPORT CLIP INSTALLATION DETAIL
H1070/H2200 EACH END & 2'-0"O.C. BETWEEN PURLINS TO TIEDOWN INSULATION
INSULATION BRIDGEMK. EIB24
RAKE ANGLEMK. MAR01
RETAINER CEEMK. IRC
(2) H1220FASTENERS
*
**
RAKE SUPPORT CLIP CL21ST@ EACH PURLIN
H1020FASTENERS
H1070 FASTENERAT EACH SUPPORT(2) H1070 FASTENERS @ EACH PURLINPRIOR TO INSULATION BEING INSTALLED
USED WHEN WALL PANELS ARE INSTALLED FIRST
SUPER TALL 4 7/8"TALL 3 7/8"***
SEE ABOVE FOR FASTENERREQUIREMENTS FOR IRC &INSULATION TIE OFF
2 1/4" TAPE MASTIC H3020BETWEEN TRIM & ROOF PANEL
ROOF PANEL
PANEL CLIP w/(2)H1020 FASTENERS
H1030 AT4" O.C.
RAKE SUPPORT CLIP MK. CL21ST w/ (2) H1220FASTENERS @ EACH PURLIN (INSTALL PRIOR TOWALL PANEL SEE DETAIL ABOVE)
RAKE SUPPORTANGLE RSA_
H1020 AT 24" O.C. W/ 3/4" TAPE MASTIC, MK. (H3000)BETWEEN ROOF PANEL & RAKE SUPPORT ANGLE
Detail Size (W x H) :By :
: CERTIFIED ERECTION DETAILSIssuedIssued
Detailer Notes:
Download the DWG file by clicking here.
RAKE DETAILSR-Boost™ ELEVATED INSULATION SYSTEM
FE2055 - STARTING RAKE DETAIL w/ ROOF JOIST & WALL SYSTEM BY OTHERS
02.12.21 (MR2021.003)DLM
1 x 2
1) N/A
SL
LOWER INSULATION
ROOF SECONDARY MEMBER (SHAPE VARIES)
UPPER INSULATION
R-Boost™ RAKE DETAIL FE2610RAKE DETAIL w/ INSULATED WALL PANELS
INSULATEDWALL PANEL
38"Ø BEAD OF BUTYL CAULKMARRY VERTICAL CAULKTO CONTINUOUS CAULK
RAKE TRIM MK. RTA__
THERMAL BLOCK (IF REQ'D)
H1020 FASTENER
(2) H1220 FASTENERS@ EACH PURLIN UNDERRAKE ANGLE FORSUPPORT (DO NOTATTACH TO RAKE ANGLE)
INSULATION BRIDGE MK. EIB24
RAKE TRIM CLEAT MK. RRA01 w/H1060 FASTENERS @ 1'-0" O.C.
RETAINER CEEMK. IRC
ROOFPANEL
H1020 FASTENER@ EACH SUPPORT
RAKE ANGLEMK. MAR01
CONTINUOUS 3/8" Ø BEAD OF BUTYLCAULK BETWEEN PANEL & EAVE ZEE
CONTINUOUS 3/8" Ø BEAD OF BUTYLCAULK IN VERTICAL JOINT (DO NOT OVERFILL)
PANEL CLIP WC-01w/(2) MEMBER FASTENERS
START/END DIM. / CUT PANEL DIM. (SEE PLAN)1/4"STEEL LINE
(NOT BY NBG)
(NOT BY NBG)
*
ERECTOR NOTE:STARTING RAKE CONDTION IS SHOWN. BRIDGE PREPERATION WILLVARY BETWEEN THE STARTING AND ENDING RAKES, SEE BRIDGEINSTALLATION DETAILS FOR SPECIFIC BRIDGE REQUIREMENTS.
*
ALT. CL21ST SUPPORT CLIP INSTALLATION DETAIL
H1020/H2200 EACH END & 2'-0"O.C. BETWEEN PURLINS TO TIEDOWN INSULATION
INSULATION BRIDGEMK. EIB24
RAKE ANGLEMK. MAR01
RETAINER CEEMK. IRC
(2) H1220FASTENERS
*
**
RAKE SUPPORT CLIP CL21ST@ EACH PURLIN
H1020FASTENERS
H1020 FASTENERAT EACH SUPPORT(2) H1070 FASTENERS @ EACH PURLINPRIOR TO INSULATION BEING INSTALLED
USED WHEN WALL PANELS ARE INSTALLED FIRST
SUPER TALL 4 7/8"TALL 3 7/8"***
SEE ABOVE FOR FASTENERREQUIREMENTS FOR IRC &INSULATION TIE OFF
RAKE SUPPORT CLIP MK. CL21ST w/ (2) H1220FASTENERS @ EACH PURLIN (INSTALL PRIORTO WALL PANEL SEE DETAIL ABOVE)
2 1/4" TAPE MASTIC H3020BETWEEN TRIM & ROOF PANEL
PANEL CLIP w/(2)H1020 FASTENERS
H1030 AT4" O.C.
RAKE SUPPORTANGLE RSA_
H1020 AT 24" O.C. W/ 3/4" TAPE MASTIC, MK. (H3000)BETWEEN ROOF PANEL & RAKE SUPPORT ANGLE
Detail Size (W x H) :By :
: CERTIFIED ERECTION DETAILSIssuedIssued
Detailer Notes:
Download the DWG file by clicking here.
RAKE DETAILSR-Boost™ ELEVATED INSULATION SYSTEM
FE2610 - STARTING RAKE DETAIL w/ INSULATED WALL SYSTEM
02.12.21 (MR2021.003)DLM
1 x 2
1) N/A
LOWER INSULATION(NOT BY NBG)
ROOF JOIST
UPPER INSULATION(NOT BY NBG)
WALL INSULATION
FE2615RAKE DETAIL w/ JOIST & INSULATED WALL PANELR-Boost™ RAKE DETAIL
SL
INSULATEDWALL PANEL
CONTINUOUS BUTYL CAULKIN VERTICAL JOINT(DO NOT OVERFILL)
ROOF PANEL
H1020 FASTENERINSULATION BRIDGE MK. EIB24
38"Ø BEAD OF BUTYL CAULK
MARRY VERTICAL CAULKTO CONTINUOUS CAULK
RAKE TRIM MK.RTA__
RAKE TRIM CLEAT"RRA01" W/ (H1060)FASTENERS @ 12"o.c.
START/END DIM. / CUT PANEL DIM. (SEE PLAN)1/4"STEEL LINE
RAKE ANGLEMK. MAR01
RETAINER CEEMK. IRCCONTINUOUS 3/8" Ø BEAD OF BUTYLCAULK BETWEEN PANEL & EAVE ZEE
H1070 FASTENER@ EACH JOIST
(2) H1220 FASTENERS@ EACH JOIST UNDERRAKE ANGLE FORSUPPORT.(DO NOT ATTACH TORAKE ANGLE)
PANEL CLIP WC-01w/(2) MEMBER FASTENERS
VARIES
TOP
OF P
ANEL
TOP OF PANEL
7 1/2"
MIN
.TO
P OF
BRI
DGE
*
ALT. CL21ST SUPPORT CLIP INSTALLATION DETAILUSED WHEN WALL PANELS ARE INSTALLED FIRST
ERECTOR NOTE:STARTING RAKE CONDTION IS SHOWN. BRIDGE PREPERATION WILLVARY BETWEEN THE STARTING AND ENDING RAKES, SEE BRIDGEINSTALLATION DETAILS FOR SPECIFIC BRIDGE REQUIREMENTS.
*
H1070/H2200 EACH END & 2'-0"O.C. BETWEEN PURLINS TO TIEDOWN INSULATION
INSULATION BRIDGEMK. EIB24
RAKE ANGLEMK. MAR01
RETAINER CEEMK. IRC
(2) H1220FASTENERS
*
**
RAKE SUPPORT CLIP CL21ST@ EACH PURLIN
H1020FASTENERS
SUPER TALL 4 7/8"TALL 3 7/8"***
SEE ABOVE FOR FASTENERREQUIREMENTS FOR IRC &INSULATION TIE OFF
H1070 FASTENERAT EACH SUPPORT(2) H1070 FASTENERS @ EACH PURLINPRIOR TO INSULATION BEING INSTALLED
2 1/4" TAPE MASTIC H3020BETWEEN TRIM & ROOF PANEL
ROOF PANEL
PANEL CLIP w/(2)H1020 FASTENERS
H1030 AT4" O.C.
RAKE SUPPORT CLIP MK. CL21ST w/ (2) H1220FASTENERS @ EACH PURLIN (INSTALL PRIORTO WALL PANEL SEE DETAIL ABOVE)
RAKE SUPPORTANGLE RSA_
H1020 AT 24" O.C. W/ 3/4" TAPE MASTIC, MK. (H3000)BETWEEN ROOF PANEL & RAKE SUPPORT ANGLE
Detail Size (W x H) :By :
: CERTIFIED ERECTION DETAILSIssuedIssued
Detailer Notes:
Download the DWG file by clicking here.
RAKE DETAILSR-Boost™ ELEVATED INSULATION SYSTEM
FE2615 - RAKE DETAIL w/ROOF JOIST & INSULATED WALL SYSTEM
02.12.21 (MR2021.003)DLM
1 x 2
1) PANEL REQUIRES 2 1/2" MINIMUM BEARING ON RAKE ANGLE TO ALLOW ROOM FOR (2) FASTENERS.