F700 Version-Up Presentation

download F700 Version-Up Presentation

of 26

Transcript of F700 Version-Up Presentation

  • 7/27/2019 F700 Version-Up Presentation

    1/26

    PVH-???-###PVH-???-###

    Mitsubishi Electric Automation, Inc.F700 Version Up Series VFD

    Empowering Greater Overall Equipment Effectiveness

    Delivering Lower Total Cost of Ownership

    Overview

    New Features

  • 7/27/2019 F700 Version-Up Presentation

    2/26

    MODEL CONFIGURATION

    Inverter type

    Model lineupApplied Motor

    kW 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160 185 220 250 280 315 355 400 450 500 560Three-phase

    200V class

    FR-F720--NA - - - - - - - - - - - -

    Three-phase

    400V class

    FR-F740--NA

    Danfoss

    ABB

    Yask.

  • 7/27/2019 F700 Version-Up Presentation

    3/26

    NEW FEATURES

    Pre-Charge Function used with PID control

    Detection of Current Input choose reaction

    Second PID function RT input triggers

    Direct Setting for PID set-point on FR-PU07-01

    Units Indicator for PID control CFM, GPM, PSI

    Three Line Selectable Monitor on FR-PU07-01

    Hand/Auto Indication on FR-PU07-01

    Built in PLC download pre-config. pump functions Two Option Ports expand available I/O points

    Built in BACnet Mitsubishi / ABB / Trane

  • 7/27/2019 F700 Version-Up Presentation

    4/26

    NEW MANUALS

  • 7/27/2019 F700 Version-Up Presentation

    5/26

    Ideal for Pumps

    Pre-charge function (Pr.760 to Pr. 769)

    This function is to drive the motor at a certain speed before starting PID

    control

    The motor is operated at Pr. 127 PID control automatic switchover

    frequencyat start until a pre-charge ending condition is satisfied

    PID control starts after a pre-charge ending condition is satisfied This function is useful for a pump with a long hose

    Without this function, PID control would start before the pump is filled

    with water, and proper control would not be performed

    Pre-charge function is also valid for a start after the PID output

    suspension (SLEEP). PID output suspension (SLEEP) function is not

    performed until the pre-charge operation ends

  • 7/27/2019 F700 Version-Up Presentation

    6/26

    Ideal for Pumps

    Pre-charge Operation (Pr.761)

    When the measured amount reaches the pre-charge ending level

  • 7/27/2019 F700 Version-Up Presentation

    7/26

    Ideal for Pumps

    Pre-charge Operation (Pr. 762)

    When the elapsed time reaches the pre-charge ending time

  • 7/27/2019 F700 Version-Up Presentation

    8/26

    Ideal for Pumps

    Pre-charge Operation

    When the signal is input to end the pre-charge operation

  • 7/27/2019 F700 Version-Up Presentation

    9/26

    Detection for current input (Pr. 573, Pr. 777, Pr. 778)

  • 7/27/2019 F700 Version-Up Presentation

    10/26

    Detection for current input (Pr. 573, Pr. 777, Pr. 778)

  • 7/27/2019 F700 Version-Up Presentation

    11/26

    Second PID function (Pr.753 to Pr. 758, Pr.765 to Pr.769)

    Possible to exchange the PID control loop by the RT terminal.

    Direct setting for PID set-point

    Easy to change the PID set-point with the

    parameter unit (FR-PU07-01).

    Direct setting menu is displayed by the one

    button (FUNC button).

  • 7/27/2019 F700 Version-Up Presentation

    12/26

    Unit Indicator for PID Control

    Possible to exchange the PID control loop by the RT terminal.

    Possible to change the unit indicator for the PID

    monitors and PID parameters on the parameter

    unit (FR-PU07-01).

    Ex.

    PSI(Pound-force per Square Inch)

    GPM(Gallon per Minute)

    CFM(Cubic Feet per Minute)

    Ideal for Fans and Pumps

  • 7/27/2019 F700 Version-Up Presentation

    13/26

    Ideal for Fans and Pumps

    Three line selectable monitor

    Possible to display the value of the selected

    monitor at the three line monitors.

    The parameter unit (FR-PU07-01) is required.

    Operation key and operation mode indication

    The operation key and the

    operation mode indication of the

    parameter unit (FR-PU07-01) are

    HAND and AUTO.

  • 7/27/2019 F700 Version-Up Presentation

    14/26

    Built-in PLC

    Ideal for Fans and Pumps

    Ability to create custom control programs- 4K steps of memory

    - Download pre-configured pump functions

  • 7/27/2019 F700 Version-Up Presentation

    15/26

    Two Option Ports Permitted

    Expand available I/O points such

    as digital inputs and outputs,

    Form C relays and analog

    Ideal for Fans and Pumps

    Only one Comm. Card at a timeTwo of the same I/O Cards not permitted

  • 7/27/2019 F700 Version-Up Presentation

    16/26

    Built in BACnet MS/TP X...

  • 7/27/2019 F700 Version-Up Presentation

    17/26

    Built in BACnet MS/TP

  • 7/27/2019 F700 Version-Up Presentation

    18/26

    Built in BACnet MS/TP

  • 7/27/2019 F700 Version-Up Presentation

    19/26

    Built in BACnet MS/TP

  • 7/27/2019 F700 Version-Up Presentation

    20/26

    Built in BACnet MS/TP

  • 7/27/2019 F700 Version-Up Presentation

    21/26

    Built in BACnet MS/TP

  • 7/27/2019 F700 Version-Up Presentation

    22/26

    Energy Savings Easy to ObserveThe effect of energy savings can be confirmed using the operation

    panel, output terminal (AM, CA terminal) and via networks with the

    newly developed energy saving monitor .

    Reminders

  • 7/27/2019 F700 Version-Up Presentation

    23/26

    PID sleep function

    Reminders

    Possible to reduce energy consumption in the

    low-efficiency, low-speed range. (Sleep function)

    Advanced PID function can

    control multiple motors (4 motors

    maximum).

    Possible to control by switchingbetween the inverter-driven

    operation and commercial power-

    driven operation.

    Multiple motors control

  • 7/27/2019 F700 Version-Up Presentation

    24/26

    NEXT STEPS

    Controlled Testing of Flux Optimization

  • 7/27/2019 F700 Version-Up Presentation

    25/26

    Thank you very muchfor your attention

  • 7/27/2019 F700 Version-Up Presentation

    26/26